Sit La Precisa S p A 058404300 Security/Remote Control Transmitter User Manual

Sit La Precisa S.p.A. Security/Remote Control Transmitter

User Manual

Download: Sit La Precisa S p A 058404300 Security/Remote Control Transmitter User Manual
Mirror Download [FCC.gov]Sit La Precisa S p A 058404300 Security/Remote Control Transmitter User Manual
Document ID2178869
Application IDIrrbj6TtSTeYQAa0r61skA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize69.88kB (873458 bits)
Date Submitted2014-01-28 00:00:00
Date Available2014-01-28 00:00:00
Creation Date2013-12-16 14:29:37
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2013-12-16 14:32:46
Document Title9957126_00_mod 16-12-2013_Proflame2_Transmitter_wall_mounted_Use and Installation Instructions 630x594 rid 64,5 GB-FR.indd
Document CreatorPScript5.dll Version 5.2.2
Document Author: BusRob

TECHNICAL DATA
IMPORTANT
The Proflame Transmitter is an integrated part of the Proflame System, which consists of these elements:
Remote Control
• Proflame Transmitter, to be used in conjunction with
• Integrated Fireplaces Control (Proflame IFC)
Supply voltage
4.5 V (three AAA LR03 1.5 V batteries)
Ambient temperature ratings
0 - 50 °C (32 - 122 °F)
The Proflame Transmitter provides for controlling the following hearth appliance functions:
Typical operative distance in free air
12 m
1. Main Burner On/Off
Radio frequency
315 MHz ( FCC version )
433.92 MHz ( CE version )
2. Main Burner flame modulation (6 levels)
WARNING
THE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCY DEVICES.
PLACING THE TRANSMITTER IN OR NEAR METAL MAY SEVERELY REDUCE THE
SIGNAL RANGE.
METALLIC STRUCTURES OR RADIO INTERFERENCES CAN REDUCE THE OPERATIVE DISTANCE
OF THE DEVICE DEPENDING ON TYPE OF FIREPLACE, INSTALLATION AND ENVIROMENT.
3. Choice of standing or intermittent pilot (CPI/IPI)
4. Thermostat and Smart thermostat functions
5. Accent light modulation (6 levels)
6. Split flow valve
7. On/Off relay
8. Comfort Fan speed modulation (6 levels)
ATTENTION!
- TURN “OFF” THE MAIN GAS SUPPLY OF THE APPLIANCE DURING INSTALLATION OR
MAINTENANCE OF THE RECEIVER DEVICE.
- TURN “OFF” MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR
REINSERTING THE BATTERIES.
- IN CASE OF REMOTE CONTROL MALFUNCTION TURN OFF THE IFC DEVICE USING
THE “ON/OFF” MAIN SWITCH.
- FOR INSTALLATION/MAINTENANCE SWITCH OFF THE IFC DEVICE REMOVING MAIN
POWER SUPPLY PLUG.
- THE DEVICE IS NOT SUITABLE FOR THE USE OF RECHARGABLE BATTERIES AND ITS
OPERATIVE DISTANCE IS REDUCED WITH LOW BATTERY LEVEL.
The Proflame Transmitter uses a streamline design with a simple button layout and informative LCD display
(Fig. 1). A Mode Key is provided to index between the features and a Thermostat Key is used to turn on/off or
index through Thermostat functions (Fig. 1 & 2). Additionally, a Key Lock feature is provided (Fig. 23).
ON/OFF Key
THERMOSTAT Key
MODE Key
Back lit LCD display
UP/DOWN Arrow Key
WALL MOUNTING
The Proflame remote control is supplied with an adapter for wall mounting.
Install the controller 1.5 m above floor level, well away from heat sources, kitchens, doors or windows.
Metallic structures or radio interferences can reduce the operative distance of the device.
Make sure to attach the adapter in a level plane without any distortion. Proceed as follow:
Fig. 1: Proflame Transmitter
•
•
•
•
Key Lock
Transmission
Low battery
alarm
9.957.126 01
Thermostat OFF/
ON/SMART
PROFLAME WALL MOUNT
TRANSMITTER
Detach the adapter from the body of the remote control; see Fig. A.
Position the adapter on the wall, mark the points for the fixing holes and drill the wall.
Fix the adapter on the wall using the mounting hardware supplied with the remote control.
Insert the remote control onto the adapter as shown in Fig. B.
Room
Temperature
CPI mode
Set Point
Temperature/Level/State
Aux ON
USE AND INSTALLATION INSTRUCTIONS
Flame ON
Split Flow
Read the instructions before use. This control must be installed in accordance with the rules in force.
Dimmer ON
Comfort fan
Fig. 2: Transmittter LCD display.
OPERATING PROCEDURE
Initializing the System for the first time
Power the receiver. Activate the procedure of the receiver
address programming, see the receiver instruction (*). The
Receiver will “beep” three (3) times to indicate that it is ready
to synchronize with a Transmitter. Install the 3 AAA type
batteries in the Transmitter battery bay, located on the base of
the Transmitter. (fig. 3) With the batteries already installed in
the Transmitter, push the On button. The Receiver will “beep”
four times to indicate the Transmitter’s command is accepted
and sets to the particular code of that Transmitter. The system
is now initialized.
Fig. A: Detach the adapter from the body
Fig. B: Adapter and remote control
Remote-Flame Control
Smart Thermostat (Transmitter Operation)
The Proflame has six (6) flame levels. With the system on, and the flame level at the maximum
in the appliance, pressing the Down Arrow Key once will reduce the flame height by one step
until the flame is turned off.
The Up Arrow Key will increase the flame height each time it is pressed. If the Up Arrow Key is
pressed while the system is on but the flame is off, the flame will come on in the high position.
( Fig. 7 & 8 ) A single “beep” will confirm reception of the command.
The Smart Thermostat function adjusts the flame height in accordance to the difference
between the set point temperature and the actual room temperatures. As the room
temperature gets closer to the set point the Smart Function will modulate the flame down.
To activate this function, press the Thermostat Key (Fig. 1) until the word "SMART" appears to
the right of the temperature bulb graphic (Fig. 11).
To adjust the set temperature, press the Up or Down Arrow Keys until the desidered set
temperature is displayed on the LCD screen of the Transmitter (Fig. 12).
Note. When Smart Thermostat is activated, manual flame height adjustment is disabled.
(*) The receiver may be independent or integrated to the IFC hearth
appliance control module. The receiver instruction may not be
independent when part of the IFC.
Fig. 7:
Fig. 3: Battery compartment.
Flame Off
Flame Level 1
Temperature indication Display
Fig. 11: Smart flame function
With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same
time. Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of
the Room Temperature display. (Fig. 4 and fig. 5)
Fig. 12
Fan Speed Control
Fig. 8:
Flame level 5
If the appliance is equipped with a hot air circulating fan, the speed of the fan can be
controlled by the Proflame system. The fan speed can be adjusted through six (6) speeds. To
activate this function use the Mode Key (fig.1) to index to the fan control icon (Fig. 13). Use the
Up/Down Arrow Keys (Fig.1) to turn on, off or adjust the fan speed (fig. 14). A single “beep”
will confirm reception of the command.
Flame Level Maximum
Room Thermostat ( Transmitter Operation)
The Remote Control can operate as a room thermostat. The thermostat can be set to a desired
temperature to control the comfort level in a room.
To activate this function, press the Thermostat Key (Fig. 1). The LCD display on the Transmitter
will change to show that the room thermostat is “ON” and the set temperature is now
displayed (Fig. 9). To adjust the set temperature, press the Up or Down Arrow Keys until the
desired set temperature is displayed on the LCD screen of the Transmitter.
Fig. 4: Remote Control display in Farenheit.
Fig. 5: Remote Control display in Celsius.
ROOM TEMPERATURE
Turn on the Appliance
With the system OFF, press the ON/OFF Key on the
Transmitter. The Transmitter display will show some other
active Icons on the screen. At the same time the Receiver
wil activate the appliance. A single “beep” from the
Receiver will confirm reception of the command.
Fig. 13
Fig. 14
Turn off the Appliance
With the system ON, press the ON/OFF Key on the
Transmitter. The Transmitter LCD display will only show
the room temperature (Fig. 6). At the same time the
Receiver will turn off the appliance. A single “beep” from
the Receiver confirms reception of the command.
SET TEMPERATURE
Fig. 6: Remote Control display.
Fig. 9
Fig. 10
Remote auxiliary relay control
Remote dimmer control (Light)
The auxiliary function controls the AUX relay outlet. To activate this function use the Mode Key
(fig. 1) to index to the AUX icon (fig. 15 & 16).
Pressing the Up Arrow Key will activate the outlet. Pressing the Down Arrow Key will turn the
outlet off. A single “beep” will confirm the reception of the command.
The dimmer function controls the Light power outlet by power light control. To activate this
function use the Mode Key (fig. 1) to index to the Light icon (fig. 19 & 20).
The intensity of the output can be adjusted through six (6) levels. Use the Up/Down Arrow Keys
(Fig.1) adjust the output level (fig. 16). A single “beep” will confirm reception of the command.
KEY LOCK
This function will lock the keys to avoid unsupervised
operation.
To activate this function, press the MODE and UP Keys at
the same time (fig. 23).
To de-activate this function, press the MODE and UP Keys
at the same time.
Note. This function is available only with the Proflame IFC.
Fig. 15
Fig. 16
Fig. 23
Fig. 19
Continous Pilot/Intermittent Pilot (CPI/IPI) selection
LOW BATTERY POWER DETECTION
Fig. 20
Transmitter
The life span of the remote control batteries depends on
various factors: quality of the batteries used, the number
of ignitions of the appliance, the number of changes to
the room thermostat set point, etc.
When the Transmitter batteries are low, a Battery Icon
will appear on the LCD display of the Transmitter (Fig. 24)
before all battery power is lost. When the batteries are
replaced this Icon will disappear.
With the system in "OFF" position press the Mode Key (fig. 1) to index to the CPI mode icon
(fig. 17 & 18).
Pressing the Up Arrow Key will activate the Continous Pilot Ignition mode (CPI). Pressing the
Down Arrow Key will return to IPI. A single “beep” will confirm the reception of the command.
NOTE: this function is available only with Proflame IFC.
NOTE: If the system is equipped with a CPI/IPI toggle switch:
• Set the CPI/IPI switch to CPI position(switch closed) to enable remote CPI/IPI
operation.
• Set the CPI/IPI switch to IPI position (switch open) to disable remote CPI/IPI
operation. The system will now work in IPI mode only regardless of the selection on
the remote control hand set.
Fig. 17
Fig. 24
Split Flow control
The secondary burner is controlled by the split Flow. To activate this function use the Mode Key
(fig. 1) to index to the SPLIT FLOW mode icon (fig. 21 & 22).
Pressing the Up Arrow Key will activate the secondary burner. Pressing the Down Arrow Key
will turn the secondary burner off. A single “beep” will confirm the reception of the command.
Fig. 18
Fig. 21
Fig. 22
DIMENSIONAL DRAWINGS
FCC CONFORMITY (for 315MHz version only)
The “Proflame Wall Mount Transmitter” complies with the following requirements:
- FCC (Federal Communications Commission) Part 15
26
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
Changes or modification not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Ø3
63
Ø3
152
FCC ID: T99058404300
26
WARNING
Fire Hazard. Can cause severe injury or death
The Transmitter causes ignition of the appliance. The appliance can turn on
suddenly. Keep away from the appliance burner when operating the remote system.
63
Dimensions in millimeters.
Fig. 24: PROFLAME Transmitter dimensional drawing
10
11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Print high-res
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2013:12:16 14:29:37+01:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2013:12:16 14:32:46+01:00
Metadata Date                   : 2013:12:16 14:32:46+01:00
Format                          : application/pdf
Creator                         : BusRob
Title                           : 9957126_00_mod 16-12-2013_Proflame2_Transmitter_wall_mounted_Use and Installation Instructions 630x594 rid 64,5 GB-FR.indd
Document ID                     : uuid:964cbbd9-1a3d-44c5-9a54-c46b6df9b655
Instance ID                     : uuid:02f25494-f14e-447b-9821-2ef44849d872
Page Count                      : 2
Author                          : BusRob
EXIF Metadata provided by EXIF.tools
FCC ID Filing: T99058404300

Navigation menu