Sivantos WL700 easyPocket remote control 3.28 MHz User Manual UserManual
Sivantos GmbH easyPocket remote control 3.28 MHz UserManual
Sivantos >
UserManual.pdf
DRA FT 2 013 -01 -21 easyPocket basic easyPocket advanced User Guide www.siemens.com/hearing Life sounds brilliant. Content Your remote control Overview Display Control buttons Key lock switch Programming connection 10 10 Batteries Inserting batteries Checking the battery status 11 11 13 Daily use Adjusting the volume Changing the hearing program Turning on and off (mute) Adjusting the tinnitus noiser level 14 14 14 16 18 Alarm clock Setting the alarm clock Ending the alarm Turning the alarm clock off 19 19 21 22 Setup and service functions Setting the time Resetting volume and hearing program Displaying contact data Setting the language of the menu 23 23 25 26 26 Content DRAFT 2013-01-21 Maintenance and care 27 Troubleshooting 28 Important information Intended use Explanation of symbols Transport and storage conditions Disposal information Technical information Conformance information 29 29 29 29 30 30 32 Important safety information Personal safety Product safety 33 33 35 Country-specific information 37 DRAFT 2013-01-21 Content Your remote control Your hearing instruments are equipped with wireless technology and can therefore be controlled by a remote control. Both easyPocket basic and easyPocket advanced provide the same basic remote control functions for listening and program change. easyPocket advanced has additional comfort functions. The operating distance of the remote control is approximately 40 inches (1 meter). u Make sure the distance between your remote control and hearing instrument does not exceed the operating distance. CAUTION Read this user guide thoroughly and completely and follow the safety information in this document to avoid damage or injury. Your remote control DRAFT 2013-01-21 Overview ૠ ➊ Display ➍ Control buttons ➋ Key lock switch ➎ Program change button ➌ Programming con- ➏ Volume up/down buttons nection More functions are available in the menu. To enter or exit the menu, press the volume up button and the volume down button simultaneously. DRAFT 2013-01-21 Your remote control Display All actions initiated with the remote control are immediately reflected on the display. For example, if you press the volume up button, the following icon is shortly displayed. The remote control does not receive information from your hearing instruments. All actions that you initiate with the controls of your hearing instruments are not reflected on the remote control’s display. Display of easyPocket basic ➊ Indicates change of hearing program and volume ➋ Alarm clock is activated Your remote control ➌ Batteries of the remote control are low ➍ Function of control buttons DRAFT 2013-01-21 Display of easyPocket advanced ➊ Indicates change of volume ➋ Program name ➌ Program icon ➍ Program number ➎ Alarm clock is activated ➏ Batteries of the remote control are low ➐ Function of programmable control buttons Power save mode If the remote control is not used for some time, the display automatically turns black. The remote control is then in its power save mode. u Press any button to activate the display again. DRAFT 2013-01-21 Your remote control Control buttons You can quickly access two functions with the control buttons on the right hand side of the remote control. The control buttons of the easyPocket advanced can be configured by your Hearing Care Professional. Small icons on the display show the functions. Basic functions Turn hearing instruments on or off. Reset to default volume and hearing program. Your remote control DRAFT 2013-01-21 Advanced functions (for easyPocket advanced only) Tinnitus noiser level up. Tinnitus noiser level down. Adjust treble. Adjust bass. All other icons: Shortcut to select a preferred hearing program. The available icons and hearing programs depend on your personal setup. DRAFT 2013-01-21 Your remote control Key lock switch u To prevent any accidental operation while the remote control is in pockets or bags, move the key lock switch to lock position (red color visible). When the key lock is active, all buttons on the remote control are disabled. The following icon is displayed. Programming connection This connection is only to be used by your Hearing Care Professional for programming the remote control. 10 Your remote control DRAFT 2013-01-21 Batteries The remote control uses two AAA batteries. Inserting batteries u Slide the battery compartment cover in the direction of the arrow. u Insert the batteries. Make sure the "+" symbols on the battery and compartment are aligned. DRAFT 2013-01-21 Batteries 11 u Attach the cover by sliding it onto the remote control. The current time setting is displayed. If you want to change it, refer to section "Setting the time". 12 Batteries DRAFT 2013-01-21 Checking the battery status When the batteries of the remote control are low, this is indicated in the status bar. Additionally, you can check the battery status at any time in the menu. u To enter the menu, press the volume up button and the volume down button simultaneously. u Navigate to the menu entry Info by pressing the vol- ume up button or the volume down button. u Confirm your selection by pressing the program change button. The battery status is displayed: battery full battery empty u To return to the standard display, press the program change button. Remove empty batteries immediately and dispose of them according to local regulations. DRAFT 2013-01-21 Batteries 13 Daily use Adjusting the volume If you are wearing two hearing instruments, the volume will be adjusted on both instruments at the same time. u Press the volume up button or the volume down but- ton to adjust the volume by one step. Changing the hearing program If you are wearing two hearing instruments, the hearing program will be changed on both instruments. The procedure for changing the hearing program differs for easyPocket basic and easyPocket advanced. easyPocket basic u Press the program change button to switch to the next hearing program. 14 Daily use DRAFT 2013-01-21 easyPocket advanced u Press the program change button repeatedly until the icon of the desired hearing program is displayed. or u Press the control button next to the icon indicating the desired hearing program. The control buttons have to be configured by your Hearing Care Professional. DRAFT 2013-01-21 Daily use 15 Turning on and off (mute) You have several options to turn your hearing instruments on and off with your remote control. Both hearing instruments are simultaneously turned on or off. When you turn your hearing instruments off via remote control, the following icon is displayed. It is displayed until you turn your hearing instruments back on. Additionally, all buttons are disabled. The only available function is to turn the hearing instruments back on. After turning on, the previously used volume and hearing program are set. Via control button u Press the control button next to the following icon to turn your hearing instruments on or off. The control buttons have to be configured by your Hearing Care Professional. 16 Daily use DRAFT 2013-01-21 Via menu Turning off: u To enter the menu, press the volume up button and the volume down button simultaneously. u Navigate to the menu entry HI Mute / Unmute by pressing the volume up button or the volume down button. u Confirm your selection by pressing the program change button. Turning on: u Press any button to activate the display. u Wait until the information about the turned off hearing instruments disappears. The menu is displayed and the HI Mute / Unmute entry is still selected. u To turn your hearing instruments back on, confirm the selection by pressing the program change button. DRAFT 2013-01-21 Daily use 17 Adjusting the tinnitus noiser level This function is only available if your Hearing Care Professional has configured the tinnitus noiser for both your hearing instruments and for the control buttons of the remote control. You can recognize the setting, if the corresponding icons are displayed next to the control buttons. u To adjust the noiser level, press the upper or the lower control button. 18 Daily use DRAFT 2013-01-21 Alarm clock You can set an alarm clock reminding you at the same time every day by a repeating signal tone and by an alarm clock icon. The alarm is initiated by the remote control but the acoustic signal is emitted by your hearing instruments. u Turn on your hearing instruments. u Keep your hearing instruments within the remote control’s operating distance. Otherwise you will not be able to hear the alarm. Setting the alarm clock u To enter the menu, press the volume up button and the volume down button simultaneously. u Navigate to the menu entry Alarm by pressing the volume up button or the volume down button. u Confirm your selection by pressing the program change button. The entry field for hours is highlighted. u Set the hours by pressing the vol- ume up button or the volume down button. DRAFT 2013-01-21 Alarm clock 19 u Confirm your setting by pressing the program change button. The entry field for minutes is highlighted. u Set the minutes by pressing the vol- ume up button or the volume down button. u Confirm your setting by pressing the program change button. The alarm on/off selection field is highlighted. u Press the volume up button or the volume down button to position the cursor next to alarm clock on: u Confirm your selection by pressing the program change button. When the alarm clock is turned on, this is indicated in the status bar. 20 Alarm clock DRAFT 2013-01-21 Ending the alarm When the alarm clock rings, a corresponding icon is displayed on the remote control. If you do not end the alarm, it is repeated within the next minutes. u To end the alarm, press the program change button. The alarm clock will ring at the same time on the next day. DRAFT 2013-01-21 Alarm clock 21 Turning the alarm clock off u To enter the menu, press the volume up button and the volume down button simultaneously. u Navigate to the menu entry Alarm by pressing the volume up button or the volume down button. u Confirm your selection by pressing the program change button. The entry field for hours is highlighted. u Press the program change button twice to skip the entry fields for hours and minutes. The alarm on/off selection field is highlighted. u Press the volume up button or the volume down button to position the cursor next to alarm clock off: u Confirm your selection by pressing the program change button. 22 Alarm clock DRAFT 2013-01-21 Setup and service functions Setting the time u To enter the menu, press the volume up button and the volume down button simultaneously. u Navigate to the menu entry Clock by pressing the volume up button or the volume down button. u Confirm your selection by pressing the program change button. The entry field for hours is highlighted. u Set the hours by pressing the vol- ume up button or the volume down button. u Confirm your setting by pressing the program change button. The entry field for minutes is highlighted. u Set the minutes by pressing the volume up button or the volume down button. u Save the settings by pressing the program change but- ton. The time is displayed. DRAFT 2013-01-21 Setup and service functions 23 The time is always displayed in the header of the menu. To enter or exit the menu, press the volume up button and the volume down button simultaneously. 24 Setup and service functions DRAFT 2013-01-21 Resetting volume and hearing program If you have made changes to volume or program and do not know why the hearing instruments are acting the way they are, you can manually set the default volume and hearing program for your hearing instruments. u To enter the menu, press the volume up button and the volume down button simultaneously. u Navigate to the menu entry HI Restore by pressing the volume up button or the volume down button. u Confirm your selection by pressing the program change button. The hearing instruments are reset and a corresponding icon is displayed. u You can also reset the hearing instru- ments by pressing the control button next to the following icon. The control buttons have to be configured by your Hearing Care Professional. DRAFT 2013-01-21 Setup and service functions 25 Displaying contact data If your Hearing Care Professional has saved his or her contact data on the remote control, you can view this information: u To enter the menu, press the volume up button and the volume down button simultaneously. u Navigate to the menu entry Contact by pressing the volume up button or the volume down button. u Confirm your selection by pressing the program change button. The contact data is displayed. u To return to the standard display, press the program change button. Setting the language of the menu u Ask your Hearing Care Professional. 26 Setup and service functions DRAFT 2013-01-21 Maintenance and care NOTICE u Do not put your remote control in water! u Do not clean your remote control with alcohol or benzine. u Clean the remote control as necessary with a soft cloth and use a nonabrasive household soap. u Avoid abrasive cleaning liquids with additives such as citric acid, ammonia, etc. DRAFT 2013-01-21 Maintenance and care 27 Troubleshooting Problem and possible solutions The remote control does not work. ■ Check, if the key lock is activated. Deactivate it, if necessary. ■ Change the batteries. Another remote control affects your hearing instruments. ■ Return remote control and hearing instruments to your Hearing Care Professional. Your Hearing Care Professional can change the wireless address to avoid interference. Consult your Hearing Care Professional if you encounter further problems. 28 Troubleshooting DRAFT 2013-01-21 Important information Intended use The remote control is intended to operate hearing instruments. Use the remote control only as described in this user guide. Explanation of symbols Points out a situation that could lead to serious, moderate, or minor injuries. Indicates possible property damage. Advice and tips on how to handle your device better. Read and follow the instructions in the user guide. Transport and storage conditions During extended periods of transport and storage, please observe the following conditions: Storage Transport Temperature 10 to 40 °C -20 to 60 °C Relative humidity 10 to 80 % 5 to 90 % Air pressure 700 to 1050 hPa 200 to 1200 hPa For other parts, such as batteries, other conditions may apply. DRAFT 2013-01-21 Important information 29 Disposal information Within the European Union, the marked equipment is covered by "Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003 on waste electrical and electronic equipment." Amended by "Directive 2003/108/EC" (WEEE). NOTICE u Recycle hearing instruments, accessories and packaging according to national regulations. NOTICE u To avoid environmental pollution, do not throw batteries into household trash. u Recycle or dispose of batteries according to national regulations or return them to your Hearing Care Professional. Technical information Siemens easyPocket FCC: SGI-WL700 IC: 267AB-WL700 Operating frequencies: Fc=3.28 MHz Maximum field strength @ 10m: -7 dBμA/m Maximum field strength @ 30m: 28.5 dBμV/m 30 Important information DRAFT 2013-01-21 FCC and IC compliance information can be found inside the battery compartment. N14203 (EMC and radio communications compliance label Australia) This Class B digital apparatus complies with Canadian ICES‑003. Changes or modifications made to this equipment not expressly approved by Siemens Audiologische Technik GmbH for compliance may void the FCC authorization to operate this equipment. FCC compliance This device complies with Part 15 of the FCC Rules and with RSS‑210 of Industry Canada. Operation is subject to the following conditions: ■ this device may not cause harmful interference, and ■ this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not DRAFT 2013-01-21 Important information 31 installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ■ Reorient or relocate the receiving antenna. ■ Increase the separation between the equipment and receiver. ■ Connect the equipment to an outlet on a circuit differ- ent from that to which the receiver is connected. ■ Consult the dealer or an experienced radio/TV techni- cian for help. Conformance information With the CE marking Siemens confirms compliance with the European Directive 93/42/EEC concerning medical devices and the European Directive 99/5/EC (R&TTE) concerning radio and telecommunications terminal equipment. 32 Important information DRAFT 2013-01-21 Important safety information Personal safety WARNING Choking hazard! Your device contains small parts which can be swallowed. u Keep hearing instruments, batteries and acces- sories out of reach of children and mentally disabled persons. u If parts have been swallowed consult a physi- cian or hospital immediately. WARNING Wireless systems may interfere with measuring devices and electronic equipment. u Do not use your device in hospitals or airplanes. DRAFT 2013-01-21 Important safety information 33 WARNING Risk of interference with active implants or life support systems! If you wear a pacemaker: u Carry the remote control at a safe distance of about 12 inches (30 cm) away from the pacemaker. u Do not carry the remote control: - in your breast pocket, - with a lanyard around your neck, - or directly on the skin over the active implant. For all other active implants or life support systems: u Prior to use, have the electromagnetic compat- ibility verified. WARNING Risk of explosion! u Do not use your remote control in explosive atmospheres (e. g. in mining areas). 34 Important safety information DRAFT 2013-01-21 Radiofrequency radiation exposure Information The radiated output power of the device is far below the FCC radio frequency exposure limits. Nevertheless, the device shall be used in such a manner that the potential for human contact during normal operation is minimized. Product safety NOTICE u Protect your devices from extreme heat. Do not expose them to direct sunlight. NOTICE u Protect your devices from high humidity. NOTICE u Do not dry your devices in the microwave oven. NOTICE Different types of strong radiation, e. g. during X-ray or MRI head examinations, may damage devices. u Do not use the devices during these or similar procedures. Weaker radiation, e. g. from radio equipment or airport security, does not damage the devices. DRAFT 2013-01-21 Important safety information 35 In some countries restrictions for the usage of wireless equipment exist. u Refer to local authorities for further informa- tion. NOTICE Your hearing instruments are designed to comply with international standards on electromagnetic compatibility but interference with nearby electronic devices could occur. In this case, move away from the source of interference. NOTICE For instruments with wireless connectivity: When the telecoil program is active, the remote control may cause a pulsing noise. u Use the remote control with a distance greater than 10 cm (4 inches). NOTICE u Your remote control is programmed to exclu- sively communicate with your hearing instruments. If you experience problems with another person's remote control, consult your Hearing Care Professional. 36 Important safety information DRAFT 2013-01-21 Country-specific information DRAFT 2013-01-21 Country-specific informatio 37 Siemens Audiologische Technik GmbH Gebbertstrasse 125 91058 Erlangen Germany Phone +49 9131 308 0 DRA FT 2 013 -01 -21 Document No. A91SAT-0####-99T##-#### ## Order/Item No. ### ### ## | Master Rev##, ##.2012 · ## Printed in Germany | © Siemens AG, ##.2012 www.siemens.com /hearing
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2013:01:21 11:38:28+01:00 Creator : Adobe InDesign CS5.5 (7.5) Modify Date : 2013:01:30 14:07:51+01:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2013:01:30 14:07:51+01:00 Creator Tool : Adobe InDesign CS5.5 (7.5) Page Image Page Number : 1 Page Image Format : JPEG Page Image Width : 256 Page Image Height : 256 Page Image : (Binary data 8020 bytes, use -b option to extract) Instance ID : uuid:ccd005bf-d58a-4921-8ff6-5471175a0fbb Document ID : xmp.did:865E4A4FB063E21196C5BA6DC9383AAC Original Document ID : xmp.did:865E4A4FB063E21196C5BA6DC9383AAC Rendition Class : proof:pdf History Action : created, saved, saved, saved History Instance ID : xmp.iid:865E4A4FB063E21196C5BA6DC9383AAC, xmp.iid:5DF7FAB8B563E21196C5BA6DC9383AAC, xmp.iid:5EF7FAB8B563E21196C5BA6DC9383AAC, xmp.iid:DB1F79A0B663E21196C5BA6DC9383AAC History When : 2013:01:21 11:31:20+01:00, 2013:01:21 11:31:31+01:00, 2013:01:21 11:31:31+01:00, 2013:01:21 11:38+01:00 History Software Agent : Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5 History Changed : /;/metadata, /metadata, /;/metadata Doc Change Count : 35 Format : application/pdf Producer : Adobe PDF Library 9.9 Trapped : False Page Count : 38EXIF Metadata provided by EXIF.tools