Skidata AS450SA00 Parking column using RFID User Manual Parking Columns unlimited

Skidata AG Parking column using RFID Parking Columns unlimited

User Manual

Download: Skidata AS450SA00 Parking column using RFID User Manual Parking Columns unlimited
Mirror Download [FCC.gov]Skidata AS450SA00 Parking column using RFID User Manual Parking Columns unlimited
Document ID441802
Application IDeiv/jj19Fug/jvaBnh1EzQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize160.87kB (2010930 bits)
Date Submitted2004-06-18 00:00:00
Date Available2004-06-18 00:00:00
Creation Date2004-06-18 12:51:57
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2004-06-18 12:51:57
Document TitleParking Columns unlimited
Document CreatorPScript5.dll Version 5.2
Document Author: bebe

Parking Columns unlimited
Manual and operational description
Parking Column AS 450 PA00
Parking Column AS 450 PA00-E
Parking Column AS 450 PA00-GC
Parking Column AS 450 PE00
Parking Column AS 450 PE00-E
Parking Column AS 450 PE00-GC
Parking Column AS 450 SA00 BLL
Parking Column AS 450 PA00-US
Parking Column AS 450 PA00-E-US
Parking Column AS 450 PA00-GC-US
Parking Column AS 450 PE00-US
Parking Column PE00-E-US
Parking Column PE00-GC-US
Parking Column SA00 BLL-US
Manual and operational description
Version April 2004
Parking Columns unlimited
SKIDATA AG
Technical Documentation
Untersbergstrasse 40
A-5083 Gartenau
Telephone
+43 6246 888-0,
Telefax
+43 6246 888-7
Internet
http://www.skidata.com
e-mail
docu@skidata.com
Copyright
© 2004 by SKIDATA AG. All rights reserved. All information in the
following document is protected by copyright law. No part of this
document may be reproduced without the written consent of SKIDATA AG. SKIDATA AG reserves the right to make any changes
of specification and other information in this document without
further notice.
Please note
During the compilation of this Technical Documentation, great
care has been taken to ensure the accuracy of the information
contained in it. However, despite our constant effort to ensure the
highest degree of accuracy and comprehensiveness possible,
the information provided cannot be guaranteed to be absolutely
error-free.
Trademarks
This documentation may contain representations of registered
product or service trademarks owned by SKIDATA AG or third
parties, as well as references to proprietary know-how protected
by copyright laws or other legal provisions. In any case the intellectual property rights remain exclusively with their respective
owners.
Declaration of Conformity
The Parking Columns unlimited except the model versions where
the name ends with the characters “-US” have been developed,
designed and manufactured in accordance with the following EU
directive:
R&TTE (99/5/EC)
0408
Page 2
© SKIDATA AG, April 2004
Manual and operational description
Parking Columns unlimited
Important : The FCC-specific notes apply only to the model version “AS 450 SA00 BLL-US”
FC
C1
5.1
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FC
C1
5.21
IMP
TANT
: Any changes to or modifications of the
AS 450 SA00 BLL-US unless expressly approved by SKIDATA
AG, may void the user's authority to operate this device.
Note: The model versions
- AS 450 PA00-US
- AS 450 PA00-E-US
- AS 450 PA00-GC-US
- AS 450 PE00-US
- AS 450 PA00-E-US
- AS 450 PE00-GC-US
contain the modular transmitter with the FCC-ID
“QSS-MECH450”.
© SKIDATA AG, April 2004
Page 3
Manual and operational description
Parking Columns unlimited
Parking Columns unlimited
Document Management – Version Table
Tab. 1: Document Version Table for Installation & Maintenance Instructions
Section Document
Pages
Version
29
2.1
Page 4
Parking Columns unlimited
Date
2004-04-24
© SKIDATA AG, April 2004
1
Parking Column unlimited
Parking Column
unlimited
Version 2.1
29 pages
Copyright 2004 by SKIDATA AG
1
1.1
Parking Column unlimited
Contents
1.1
Contents
1.1
Contents
1.2
1.2.1
1.2.1.1
System APT 450 – Columns unlimited
Versions of Parking Column Unlimited
Parking column unlimited – “Standard” (AS 450
PA00,
AS 450 PE00, AS 450 PA00-US, AS 450 PE00-US) 3
Parking column unlimited – “Extended” (AS 450
PA00E, AS 450 PE00-E, AS 450 PA00-US, AS 450 PE00US)
Parking column unlimited – “Graphic” (AS 450 PA00GC, AS 450 PE00-GC, AS 450 PA00-GC-US, AS 450
PE00-GC-US)
Parking column unlimited – “handsfree” (AS 450
SA00- BLL, AS 450 SA00 BLL-US)
Installation of Parking column unlimited
Warning
Preparation for Installation
Installation
Installation on non-level surfaces (applies only in
exceptional circumstances)
Power supply
10
Note
10
Stripping connection wires
12
Cross-sectional area of cable leads
13
Power supply
13
Connection terminals for control lead and intercom 15
Loop Connections, Standard-Version, GraphicsVersion, Handsfree-Version
18
Loop connections, Extended-Version
19
Earthing connection
20
Changing the fuse
21
Surge protection for external devices
21
Weather protection
22
MANUAL OPEN/CLOSE switch
23
Installing devices in the front panel
24
Opening the front panel
25
Closing the Parking Column
25
Installing and Deinstalling the Coding Unit
(except Handsfree-Version and OEMVersion)
27
1.2.1.2
1.2.1.3
1.2.1.4
1.2.2
1.2.2.1
1.2.2.2
1.2.2.3
1.2.2.4
1.2.3
1.2.3.1
1.2.3.2
1.2.3.3
1.2.3.4
1.2.3.5
1.2.3.6
1.2.3.7
1.2.3.8
1.2.3.9
1.2.3.10
1.2.4
1.2.5
1.2.6
1.2.7
1.2.8
1.2.9
Page 2
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
System APT 450 – Columns unlimited
1.2
1.2
System APT 450 – Columns
unlimited
1.2.1
Versions of Parking Column Unlimited
1.2.1.1
Parking column unlimited – “Standard”
(AS 450 PA00, AS 450 PE00, AS 450 PA00US, AS 450 PE00-US)
Fig. 1:
Parking Column unlimited –
“Standard”
© SKIDATA AG, Version 2.1
Page 3
1
1.2
Parking Column unlimited
System APT 450 – Columns unlimited
1.2.1.2
Parking column unlimited – “Extended”
(AS 450 PA00-E, AS 450 PE00-E, AS 450
PA00-US, AS 450 PE00-US)
Fig. 2:
Parking Column unlimited - ”Extended”
Page 4
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
System APT 450 – Columns unlimited
1.2.1.3
1.2
Parking column unlimited – “Graphic”
(AS 450 PA00-GC, AS 450 PE00-GC, AS 450
PA00-GC-US, AS 450 PE00-GC-US)
Fig. 3:
Parking Column unlimited ”Graphic”
© SKIDATA AG, Version 2.1
Page 5
1
1.2
Parking Column unlimited
System APT 450 – Columns unlimited
1.2.1.4
Parking column unlimited – “handsfree”
(AS 450 SA00- BLL, AS 450 SA00 BLL-US)
Fig. 4:
Parking Column unlimited ”handsfree”
Page 6
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
1.2
System APT 450 – Columns unlimited
1.2.2
Installation of Parking column unlimited
1.2.2.1
Warning
General Warning:
PCBs are sensitive to electrostatic discharge and should be
handled with great care to avoid damage to the circuitry.
Avoid touching the boards unnecessarily. Before mounting the
column, check the entire device for possible transport damage.
Before accessing electronical or mechanical parts, the entire
deviced must be disconnected from the mains.
1.2.2.2
Preparation for Installation
Ensure the following before proceeding with the installation:
„The concrete foundation must be exactly horizontal. Installing
the device on an uneven surface may cause the chassis to
become warped or damaged. If levelling of the surface is not
possible, the parking column must be level-adjusted, e.g. by
using additional hexagon nuts; in that case the threaded rods
must be allowed to protrude further.
„The surface of the concrete foundation must be even and exactly horizontal
„Cable protection tubes should be cut approx. 2 cm above the
concrete surface
1.2.2.3
Installation
„The threaded rods should protrude approx. 50 mm from the
concrete surface
„The fastening tension of the hexagon nuts must not exceed
20 Nm
„Use washers with large outer diameter (∅ = 30 mm, as per
UN 737 standard)
„The parking column must be aligned exactly horizontally
© SKIDATA AG, Version 2.1
Page 7
1
1.2
Parking Column unlimited
System APT 450 – Columns unlimited
Fig. 5: Column installation
Page 8
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
1.2
System APT 450 – Columns unlimited
1.2.2.4
Installation on non-level surfaces (applies
only in exceptional circumstances)
Fig. 6:
Hexagon nuts as spacers
All three No. 2 washers must be absolutely level (use a spirit
level if necessary).
Important:
Avoid drilling dust from getting into the device during installation, as electrostatically charged dust may cause damage to
the electronic assemblies inside the column.
© SKIDATA AG, Version 2.1
Page 9
1
1.2
Parking Column unlimited
System APT 450 – Columns unlimited
1.2.3
Power supply
1.2.3.1
Note
Important notes:
Electric installation and maintenance work may be carried
out only by appropriately qualified, licensed electrical
technicians.
Mains connections must be hardwired.
Please ensure full compliance with all applicable national and
international rules and regulations concerning electric connections, and all applicable safety regulations.
„When all electric lines are properly connected, replace and
fasten the cover
Page 10
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
1.2
System APT 450 – Columns unlimited
Fig. 7:
Column interior:
Mounting plate configuration
Ensure the following before proceeding with electrical connections:
„Check for proper mains supply voltage (120 or 230 VAC); see
type label
„Mains connections must comply with national standards and
directives
„When using flexible stranded wires, all filaments must be
placed inside the terminal clamps (use wire-end sleeves, if
necessary)
© SKIDATA AG, Version 2.1
Page 11
1
1.2
Parking Column unlimited
System APT 450 – Columns unlimited
„The mains supply line must be fused in accordance with ap-
plicable regulations (6 A fuse recommended)
„Check the isolation resistance of the cables to make sure it
exceeds 0,5 MΩ
„Fix cables to mounting plate by way of tension relieve tongues
and cable ties
„Check the network cables to ensure the proper loop impedance
Important: Always make sure that the device is completely
disconnected from the mains while fitting electric wiring.
1.2.3.2
Stripping connection wires
To avoid danger of short circuit with wires or chassis parts, wires
should not be stripped by more than 6 mm (recommended
value). Uninsulated wire sections must be inserted completely
into the connection terminals.
When attaching connecting wires, the insulation should cover the
wire up to the point where it connects to the terminal.
Fig. 8:
Correct connector wiring
Page 12
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
1.2
System APT 450 – Columns unlimited
1.2.3.3
Cross-sectional area of cable leads
Tab. 1: Cable leads – Technical characteristics
wires
Max. torque at terminals
Rigid
Solid
Flexible
Twisted
0,22 – 0,25 Nm
0,14 – 1,5 mm²
0,14 – 1,5 mm²
**
0,5 – 0,6 Nm
0,20 – 2,5 mm²
0,20 – 2,5 mm²
***
0,22 – 0,25 mm²
0,14 – 1,5 mm²
0,14 – 1,0 mm²
1.2.3.4
Power supply
Fig. 9:
Power supply on sd591
** see Section 1.2.3.3
© SKIDATA AG, Version 2.1
Page 13
1
1.2
Parking Column unlimited
System APT 450 – Columns unlimited
Caution:
The OUT terminal on connection control board sd591 is not
fused and cannot be deactivated by way of the on-board mains
switch.
Note:
Electrical leads and wires must comply wirth applicable national guidelines concerning
– mechanical stress
– tension resistance
– cross-sectional area with respect to voltage drop
– current carrying capacity and short-circuit rating
„To install electrical fittings, you must first remove the cover of
control board sd591
Page 14
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
System APT 450 – Columns unlimited
1.2.3.5
1.2
Connection terminals for control lead and
intercom
Fig. 10:
Connection terminals for control
lead and intercom
* see Section 1.2.3.3
© SKIDATA AG, Version 2.1
Page 15
1
1.2
Parking Column unlimited
System APT 450 – Columns unlimited
Fig. 11:Connections on control board sd582
*** siehe 1.2.3.3
Page 16
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
System APT 450 – Columns unlimited
1.2
Fig. 12:
sd582 – I/O circuit connections
Note on wire twisting:
When connecting Arcnet and loop cables, make sure that the
wires are twisted up to the connection terminal (approx. 5
twists per 10 cm).
Shield connections must be as short as possible and insulated
against contact with the chassis wall by means of a protective
tube.
© SKIDATA AG, Version 2.1
Page 17
1
1.2
Parking Column unlimited
System APT 450 – Columns unlimited
1.2.3.6
Loop Connections, Standard-Version,
Graphics-Version, Handsfree-Version
Fig. 13:
Loop connections, StandardVersion, Graphics-Version,
Handsfree-Version)
Page 18
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
System APT 450 – Columns unlimited
1.2.3.7
1.2
Loop connections, Extended-Version
Fig. 14: Loop connections, Extended-Version)
© SKIDATA AG, Version 2.1
Page 19
1
Parking Column unlimited
1.2
System APT 450 – Columns unlimited
1.2.3.8
Earthing connection
The protective earth conductor of the lead must be attached to
the central earthing point by way of a ring lug (see connection
layout in Fig. 9).
Fig. 15:
Earthing point
Fig. 16:
Protective earth
conductor
„After installation, ensure proper metal contact of all aluminium
parts, i.e. the cable lug and/or metal part (check by measuring)
„If necessary, mill off any aluminium parts at the contact point
to ensure proper conductivity (the resistance of the earth conductor must not exceed 0,1 ȍ)
After connecting the earth conductor, proceed as follows:
„Check the strain relief clamps for proper fit
„Check to make sure the cables leading to the connection ter-
minals are properly placed in accordance with applicable
norms
Page 20
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
1.2
System APT 450 – Columns unlimited
„Perform a visual check of the insulation to ensure it is in
proper condition
„Slightly tug at the wires to check whether the terminal screws
are fastened properly
„Chek to ensure the connectors are plugged in properly
„Reattach the cover of sd591
„Perform a visual check and manual inspection of the earthing
connection
„Check to make sure that none of the wires are strained
Note:
If the Parking Column is powered up at temperatures below 2
°C, the control assembly will not start up to prevent possible
damage. In that case, the built-in temperature control system
will activate the heater (make sure that all doors are closed to
allow for the device to warm up as quickly as possible).
1.2.3.9
Changing the fuse
Important Note:
A blown fuse indicates a device defect that requires the attention of a trained service technician. The fuse must be replaced by a new one of the same type and technical
characteristics (see below). Before replacing the fuse, the lead
in the power distributor must be deactivated (i.e., disconnected
from the mains).
Fuse characteristics:
120 VAC = 5 A–T
230 VAC = 2,5 A–T
Model:
Type:
Time lag:
High breaking capacity:
Ceramic tube
Schurter
SPT 5x20
1.2.3.10 Surge protection for external devices
In case additional devices (e.g., relays, controls, etc) are installed
inside the chassis (on the top-hat rail) any relay contacts and coil
connections must be protected against transient voltage by
means of appropriate components (e.g., diodes, RC elements,
varistors, etc).
© SKIDATA AG, Version 2.1
Page 21
1
1.2
Parking Column unlimited
System APT 450 – Columns unlimited
1.2.4
Weather protection
Important:
Opening the device while it is exposed to rain or snowfall may
cause damage to the components inside.
To avoid moisture damage when performing installation work,
you can protect the open device against moisture by means of
an umbrella (see illustration below).
Before opening the device during or shortly after a rain or
snow shower, use a cloth to wipe down the top cover and upper edge of the front panel to avoid moisture getting inside the
device.
Fig. 17:
Using an umbrella for moisture
protection when performing maintenance work
Page 22
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
System APT 450 – Columns unlimited
1.2
Fig. 18:
Column top – Detail: umbrella
holding frame
1.2.5
MANUAL OPEN/CLOSE switch
Fig. 19:
OPEN/CLOSE switch on sd591
Switch positions
„Position 0: Normal operation
„Position 1: Keep CLOSED
„Position 2: Keep OPEN
Single gate passage
„Briefly set the switch to position 2; after the barrier opens, set
it back to the 0 position
© SKIDATA AG, Version 2.1
Page 23
1
1.2
Parking Column unlimited
System APT 450 – Columns unlimited
„If no vehicle passes through the gate, the barrier will close
automatically after approximately ten seconds
1.2.6
Installing devices in the front panel
Fig. 20:
Installing devices in the front
panel
Important: Devices and cables intended for subsequent installation must bear a CE label (EU countries) or UL/CSA label (USA; Canada) and must comply with all national and
international standards and guidelines. Installation of such
components may only be performed by qualified electricians.
Page 24
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
System APT 450 – Columns unlimited
1.2
CAUTION:
When installing devices in the front panel, ensure a minimum
clearance of 5 cm above the fan-heater (see illustration).
The fan-heater must never be covered to avoid the danger
of fire.
To avoid damage to the device, make sure that the fastening
screws of the mounting plate are not screwed in too tightly
(max. torque 0,5 Nm).
When cutting out the metal plate, make sure it is not warped,
as this may cause water to leak into the device.
After installing the desired device(s), check the chassis for
tightness against water and snow.
1.2.7
Opening the front panel
To open the front panel, open the column door and pull the locking lever on the inside of the chassis wall forward (see illustration).
Fig. 21:
Opening the front panel
1.2.8
Closing the Parking Column
„Close the top cover and the front panel
„After locking the column door, slide the dust cover back over
the lock (see Fig. 1)
© SKIDATA AG, Version 2.1
Page 25
1
1.2
Parking Column unlimited
System APT 450 – Columns unlimited
Important:
If the front panel is not closed tightly, water or snow may get
inside the device, causing damage to the electronic assemblies.
After closing the front panel, pull at it slightly to make sure it is
properly closed and locked shut.
Fig. 22:
Closing the column top section
Page 26
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
System APT 450 – Columns unlimited
1.2.9
1.2
Installing and Deinstalling the Coding Unit
(except Handsfree-Version and OEMVersion)
To be able to access the Coding Unit for maintenance purposes,
you must first open the front panel (see illustration).
Fig. 23:
Parking Column unlimited – Coding Unit
The device is secured to the draw-out support plate by means of
four mounting pegs (indicated by arrows in the illustration below).
Fig. 24:
Coding Unit mounting pegs
(Bottom view)
© SKIDATA AG, Version 2.1
Page 27
1
1.2
Parking Column unlimited
System APT 450 – Columns unlimited
Deinstallation
„Before you dismount the coding unit, it is essential that you
unplug all cables and disconnect the Column from the power
supply
„Using your thumb to give you leverage, detach the front panel
of the Coding Unit from the support plate (see illustration below) and lift it out of its anchoring (note that you will need to
overcome a resistance to do so)
Fig. 25:
Lifting the front section of the
Coding Unit
„Next, hold the Coding Unit by the ticket slot, raise it out of its
rear anchoring (again overcoming a slight resistance) and lift
it off the support plate
Page 28
© SKIDATA AG, Version 2.1
1
Parking Column unlimited
1.2
System APT 450 – Columns unlimited
Fig. 26:
Deinstalling and installing the
Coding Unit
Installation
„To reinstall the Coding Unit, hold it by the ticket slot, place it
on the rear pegs and press it down until it locks into place
„Next, place the front panel of the Coding Unit on the two front
pegs and press it down until it also locks into place (in doing
so, place your hand against the support plate to avoid it getting warped)
„When re-installing the coding unit, use one hand to apply
counter-pressure to the mounting plate from below as you
press down the coder into place with your other hand. This is
to prevent the mounting plate from warping as a result of the
downward pressure being applied during the installation.
„Finally, push the support plate back in as far as it will go
Wear protection
„After locking the column door, remember to slide the dust
cover over the lock to prevent dust and dirt from getting inside
© SKIDATA AG, Version 2.1
Page 29

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 33
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:b25539e5-a0f8-4623-a46e-8a54c1ba3b37
Producer                        : Acrobat Distiller 6.0 (Windows)
Create Date                     : 2004:06:18 12:51:57+02:00
Modify Date                     : 2004:06:18 12:51:57+02:00
Metadata Date                   : 2004:05:25 15:53:02+02:00
Creator Tool                    : PScript5.dll Version 5.2
Document ID                     : uuid:37616a16-9b20-49aa-872c-adf71f0d7427
Format                          : application/pdf
Creator                         : bebe
Title                           : Parking Columns unlimited
Description                     : Parking Columns unlimited
Author                          : bebe
Subject                         : Parking Columns unlimited
Keywords                        : Parking, Columns, unlimited
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QSS-AS450SA00

Navigation menu