Skytech II AF-4000PEHH Transmitter User Manual user s manual

Skytech II, Inc. Transmitter user s manual

users manual

Download: Skytech II AF-4000PEHH Transmitter User Manual user s manual
Mirror Download [FCC.gov]Skytech II AF-4000PEHH Transmitter User Manual user s manual
Document ID647739
Application IDbyy8UlRgZiIJ61lS+O0u1w==
Document Descriptionusers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize38kB (474941 bits)
Date Submitted2006-04-17 00:00:00
Date Available2006-04-14 00:00:00
Creation Date2006-03-30 17:14:38
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2006-03-31 15:01:25
Document TitleMicrosoft Word - user's manual.doc
Document CreatorPScript5.dll Version 5.2
Document Author: Heron

Function Dscription
z Button
set timer & cancel
timer
function
aft
Dr
On/Off button for
Manual mode
AUX1 button
Use this key to
enter into & set
Program mode
AUX2 button
Thermo mode
A long push (5 seconds) of A1 & A2 buttons at the same time will start the Initial Set-up.
At this time, a separate push for A1 &A2 buttons does not light any operations on the
LCD.
A short push of P button will enter into PROGRAM mode.
A long push (5 seconds) of P button will enter into the setting for PROGRAM mode.
*A long push (5 seconds) of TIMER & THERMO mode at the same time will activate or
de-activate the CP feature.
z
LCD icon:
thermo
Timer
Manual ON
Program
Set temperature
Battery low
Flame UP
FLAME
aft
Dr
Thermostat
Thermostat NOT
Flame down
AUX1
CP:Chil
d Proof
AUX2
Pacific energy
company icon
Program mode setting
and display area
Set Temperature: This will ONLY appear when the THERMOSTAT is activated
- Timer: Timer Mode will appear and activate the Timer.
- Manual ON: When manual ON , the MAN Icon will appear and when manual OFF
the MAN icon will be eliminated
- Program Mode: This icon will appear when the program is working
- Thermostat : This icon will appear only when the Thermostatic Function is operating
the fireplace.
- Thermostat NOT : Tthis icon will ONLY appear(for 5 seconds) on the LCD screen
when the Thermostatic function has been de-activated and someone will try to push
the Thermostatic function button of the transmitter. This will show the user the
thermostatic function is de-activated.
Notes:
aft
Dr
The range for the room temperature readout is 32-99 degree F.
The room temperature always displays on the LCD.
The range for set temperature is 45- 99 90degree F.
The High Limit temperature for PROGRAM mode is 90 degree F.
This High Limit termperature can not be changed by the users and
Will only activate under PROGRAM mode.
There is no High
Limit temp for MANUAL & THERMO modes.
The room temperature (
The AUX1 and AUX 2 (
) always displays on the LCD
) do not light any operations on the LCD at this time.
NOTE: Very Important to note
Only one function can be going on at one time. You will have only one
operation at a time going on with this system. The pressing of one of the
function buttons will stop the operation that is going on with the fireplace
and start the new function.
Definition of Functions: Timer, Manual ON/OFF, Thermostat, and Program.
Timer” is considered an independent function.
The users are unable to set “Timer” function under Manual & Thermo
modes.
The users can adjust the Flame (operate the motor drive) under Manual ON,
THERMO, TIMER & PROGRAM modes.
SWING:
Pacific Energy after discussion would like to have the following in the swing
without the user having the ability to adjust this swing in any way.
Above the Room Temperature 1degree F and .5 degree C, 1 degree swing
above
Below the Room Temperature 2 degree F and 1 degree C, 2 degree swing
down
THESE SETTING CANNOT BE CHANGED, IT IS SET AT THE FACTORY
AND IN THE PROGRAM.
It is not necessary to display SWING on the LCD..
The FLAME icon will be ON all the time the flame in the fireplace is ON, whether
it is under Manual ON, TIMER, THERMOSTAT or PROGRAM modes.
The UP arrow will appear on the LCD when the motor drive is to be moving into
the higher flame picture. Once the activation of the flame height is stopped, the
UP icon on the LCD will disappear.
The DOWN arrow will appear on the LCD when the motor drive is to be moving into
the Lower flame picture. Once the activation of the flame height is stopped, the
DOWN icon on the LCD will disappear.
aft
Dr
Operation Matrix
Initial Set up: Push AUX 1 & AUX 2 buttons together for more than 5
seconds to start the process.
C/F conversion: Use UP or DOWN key to choose Celsius or
Fahrenheit, then press OK to enter “TIME”.
Setting.
Use UP or DOWN key to set HOUR, then press OK to
enter “Minute” setting.
Use UP or DOWN key to set “Minute”, then press OK
To enter AM/PM setting.
Use UP or DOWN key to set AM/PM, the press OK to
Enter “DAY” setting.
Use UP or DOWN keys to set correct DAY, then press OK to
finish the initial set up.
The users must use OK button to confirm and enter into next setting.
The icons will keep on flashing even though no button is pushed for more
5 seconds.
H’ever, if no buttons is pushed for more than 2 minutes,
the system will automatically confirm the completion of the process and
the LCD will go back to Normal readouts.
Temperature swing:. This is factory set and can not be changed at all.
Manual Mode: Push
ON: The “man"(
for manual ON, OFF.
) ICON will appear
And the FLAME icon will appear too.
OFF: The man (
) ICON will disappear and
The FLAME icon will disappear too.
aft
Dr
.Flame modulation: The flame can only be modulated when the system is ON. The
flame can be ON from the Manual, Timer, Thermostat and Program modes.
The FLAME icon should be on all the time the flame in the fireplace is ON, whether
It is operated in Manual, Timer, Thermostat or Program modes.
The UP arrow will appear on the LCD when the motor drive is to be moving into
the higher flame picture. Once the activatin of the flame height is stopped, the UP
icon on the LCD will disappear.
The DOWN arrow will appear on the LCD when the motor drive is to be moving into
the Lower flame picture. Once the activation of the flame height is stopped, the
DOWN icon on the LCD will disappear.
Push
(UP) button to operate flame motor drive UP.
When this key is
pushed, the UP icon will appear. The UP icon will disappear once the activation of the
flame height is stopped (when the button is released.)
Push
(DOWN) button to operate flame motor drive DOWN.
When this
key is pushed, the DOWN icon will appear .The DOWN icon will disappear once the
activation of the flame height is stopped (when the button is released).
.Timer function: Once this is selected, the timer (
) icon will be on the screen and the
clock will flash “30"minutes as the start point. But the users still can go down to
10 minutes and up to 180 minutes.
The 10-minute segments remains unchanged.
By pushing
(TIMER) button, You can set TIMER or cancel
TIMER function.
aft
Dr
You use
(DOWN) or
(UP) button to set your
desired TIMER.
9 The range of TIMER is from 10 minutes to three hours or 180
minutes, in 10 minute segments.
IMPORTANT:Once the timing range is set, the user MUST
push
(OK) button to activate the Timer. IF THE
“OK"BUTTON IS NOT PUSHED, THE ORIGINAL FUNCTION
WILL CONTINUE TO OPERATE. In another words, Pacific Energy
would like to have the user too push the OK button to change the function.
The clock will start the countdown right after the completion of the
TIMER setting.
At this time, if the
(TIMER) button is
pushed again, the TIMER function will be canceled. You'll have
to push the TIMER button again if you want to use the TIMER
function again.
.Thermo mode:
Selection of
(THERMO) button will light the temperature
ICON and will light the smaller set of numbers (
aft
Dr
The SET area should flash to 5 seconds and during this period of time the UP and Down
arrows will operated the Set Temperature to the correct setting. Once the correct
temperature is obtained, the temperature will continue to flash for 5 seconds and then it
will stop flashing (This means the SET process is completed.) The user will not have to
operate the “OK" button to set the temperature. But if the OK button is pushed, it
also completes the process for setting temperature.
You can use
(DOWN) or
(UP) buttons to
obtain the desired temperature. Then you can either let the
set area flash for 5 seconds or push the OK button to complete this process.
We should be able to operate the UP and DOWN arrows will direct the motor drive ONLY
after the 5 seconds of flashing.
On the backside of the TX, there is an unmarked recessed button,
you can completely turn off the THERMOSTATIC function of this
remote by pushing this recessed button.
This recessed button has sequence of events to turn on & off
The THERMOSTATIC function.
The “THERMOSTAT NOT" icon on the LCD screen will
appear for 5 seoncs only when the THERMOSTATIC function
is completed turned off.
This “THERMOSTAT NOT icon will light for 5 seoncs if the
THERMO button on the front of the TX is pushed.
In another words, this “THERMOSTAT NOT" icon will
NOT appear all the time.
.
Program mode:
(PROGRAM) button will select/operate the
A short push of
PROGRAM mode. A long push (push & hold for more than 5 seconds)
aft
Dr
of
button will enter into the Setting of PROGRAM mode.
Following are the Factory setting for the PROGRAM mode:
MTWTF Segment 1(P1) On - 7:00am
SS
Off
Segment 2(P2) On 5:00pm
Segment 1(P1) On 9:00am
Segment 2(P2) On 6:00pm
Push & hold
8:00am
Off 7:00pm
Off 10:00am
Off 9:00pm
button for more than 2 seconds to enter the
setting for program mode:
on LCD
will flash, then you can use
or
the setting of “P1 ON". Then you push OK (
to change
button to enter into next setting.
flash, then you can use
setting of “P1 OFF".
on LCD will
or
to change the
Then, push OK button to enter into
next setting.
Then use
ON".
will flash.
or
to change the setting of “P2
Then, use OK button to enter into next setting.
will flash.
aft
Dr
Then use
or
to change the setting of
“P2 OFF". Then, push OK button to enter into next setting.
SS &
You can use
on the LCD will flash.
or
to change the setting of
“P1 OFF". Then, push OK button to enter into next setting.
SS &
You can use
on the LCD will flash.
or
to change the setting of
“P1 OFF". Then you push OK button to enter into next
setting.
SS &
or
You can use
“P2 ON”.
SS &
You can use
“P2 OFF”.
.CP (CHILD PROOF):
on the LCD will flash.
to change the setting of
Then, you use OK button to enter next setting.
on the LCD will flash.
or
to change the setting of
Then, you use OK button to finish the setting.
*This feature is to be activated/de-activated by push TIMER/THERMO keys at the
Same time for more than 5 seconds..
*When this feature is activated, the LOCK icon will appear for 5 seconds and then
disappear. This LOCK icon will appear for 5 seconds again and then disappear
if any of the buttons of the TX is pushed. This tells the users that the TX is
LOCKED.
aft
Dr
FCC Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO
OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO
THIS EQUIPMENT.
SUCH MODIFICATIONS COULD VOID THE USER’S
AUTHORITY TO OPERATE THE EQUIPMENT.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 10
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:c295334f-1d76-474e-bd4b-2c685c718457
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2006:03:30 17:14:38+08:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2006:03:31 15:01:25+08:00
Metadata Date                   : 2006:03:31 15:01:25+08:00
Document ID                     : uuid:9afd8f5a-d325-48b5-8515-c9bd54384f28
Instance ID                     : uuid:bb652091-1be8-46ef-925c-102b4819c608
Format                          : application/pdf
Title                           : Microsoft Word - user's manual.doc
Creator                         : Heron
Author                          : Heron
EXIF Metadata provided by EXIF.tools
FCC ID Filing: K9LAF-4000PEHH

Navigation menu