Residential • Gas fired • Hot Water Boilers

User’s Information Manual
Bobcat Direct-Vent Sealed Combustion Condensing Boiler
Model B-120A and B-200A
FOR YOUR SAFETY:
• Before operating this boiler, READ this manual.
• DO NOT attempt to install, service or repair this boiler yourself. There are no user serviceable
parts. Contact a qualified service agency if your boiler needs repair or maintenance. Ask your gas supplier for a
list of qualified service agencies.
• A qualified service agency should inspect the venting system of this boiler on an annual basis.

WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury or loss
of life.

__ DO NOT store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.

__ WHAT TO DO IF YOU SMELL GAS
• DO NOT try to light any appliance.
• DO NOT touch any electrical switch
• DO NOT use any phone in your
building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.

__ Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Your gas boiler must be installed and serviced by a qualified service agency or gas
supplier. The lack of proper service can result in a dangerous condition.
This manual must be left with owner, hung on or
adjacent to the boiler. Owner should retain manual
for future reference.
Printed in U.S.A. 808

Part No. 86-5757000

Publication No. BA-UIM

Bobcat Model B-120A and B-200A

2

Figure 1. Location and identification of parts. (model 120A shown)

WELCOME TO OUR VALUED CUSTOMER
You are now the owner of a Slant/Fin Bobcat series gas-fired
boiler, another quality heating product designed and manufactured by an industry leader, to provide your family with
many years of reliable comfort and trouble-free performance.
The care and maintenance of your new boiler is important to
prevent a hazardous condition which might result form lack
of proper servicing. Therefore, you should perform regular
“owner” inspections as described in this manual (and report
any concerns to a qualified service technician) as well as
have your boiler serviced by a qualified service technician at
least once a year, preferably before the beginning of each
heating season.

LIGHTING INSTRUCTIONS
Locate, read and then follow the procedures on the lighting
instructions label attached to the boiler. For reference, we
have reproduced those instructions in this manual.

DO NOT use this boiler if any part has been
underwater. Immediately call a qualified service
technician to inspect the boiler and to replace
any part of the control system and any gas
control which has been underwater.

WARNING
Should overheating occur or the gas supply
fail to shut off, DO NOT turn off or disconnect
the electric supply to the circulator pump.
Instead, shut off the gas supply at a location
EXTERNAL to the appliance.

WARNING
SLANT/FIN DOES NOT PERMIT THE USE OF
VENT DAMPERS ON BOBCAT B-120 or B-200
SERIES BOILERS. OTHER DAMPERS OR
DEVICES WITH SIMILAR PURPOSE ARE NOT
PERMITTED.

Keep the boiler area clean and free of all materials that can burn.
NEVER close or reduce openings that supply air for the boiler fire and for ventilation.

Bobcat Model B-120A and B-200A

3
INSPECTION
Your boiler and heating system will last an indefinitely long
time at full efficiency, if it is inspected regularly and is kept
in good repair and adjustment. You, the user, should make
regular inspections, and report any problems to your
service agency. At regular intervals, you should have that
agency inspect the system and make repair adjustments as
necessary. What you and the service agency should do is
listed below. Contact your gas supplier for a list of qualified
service and repair agencies.
USER INSPECTION
The user should make the following inspections at least
once each month during the heating season and once just
before cold weather starts. Bobcat B-120 and B-200 boilers may be installed and vented either as direct-vent boiler, which all air for combustion is obtained directly from
outside through the air intake piping or as non-directvent boiler, which all air for combustion is taken from
inside the boiler room. Typical direct-vent installations are
shown on Figures 2 and 3. Non-direct-vent installation is
shown on Figures 4, 5 and 6.

1. VENTING AND AIR INTAKE SYSTEM REGULAR
INSPECTION
Inspect the system regularly for condensation, corrosion,
sagging and/or physical damage. A qualified professional
should service the boiler annually and include such an
inspection at that time. The homeowner should look over the
system monthly for damage, water stains, any signs of rust,
other corrosions or separation of the vent and air intake
piping (if direct-vent).
Should an inspection turn up signs of condensation,
corrosion, sagging or damage, the boiler should be shut
down immediately and the condition should be corrected by
a qualified professional.
If the boiler is vented horizontally through the wall, the
outside termination, louvers and screen should be checked
for any debris blocking the opening and cleaned as
required.

VENT
TERMINATION

3” DIA.
VENT PIPE

AIR INTAKE

OUTSIDE
TERMINATION
PANEL
VENT
TERMINATION
3” DIA.
AIR INTAKE
PIPE

E
AK
INT RS
R
E
AI UV
LO

3” DIA.
VENT PIPE

OUTSIDE
WALL

Figure 2. Direct vent, sidewall venting illustration.

3” DIA.
AIR INTAKE
PIPE

Figure 3. Direct vent, venting and air intake
through a roof.

Bobcat Model B-120A and B-200A

4

3 IN. DIA.
VENT PIPE
VENT
TERMINATION

AIR INTAKE
(DO NOT BLOCK)

OUTSIDE WALL

Figure 4. Non-direct vent, sidewall venting.

Bobcat Model B-120A and B-200A

5

VENT
TERMINATION

3 IN. DIA.
VENT PIPE
AIR INTAKE
(DO NOT BLOCK)

Figure 5. Non-direct vent, venting through the roof.

CHIMNEY
TOP PLATE

VENT
TERMINATION

UNUSED
CHIMNEY
3 INCH DIA.
VENT PIPE

3 INCH DIA.
VENT PIPE
AIR INTAKE
(DO NOT
BLOCK)

Figure 6. Non-direct vent, utilizing an existing chimney as a chase.

Bobcat Model B-120A and B-200A

CONDENSATE TRAP,
FILLED WITH
WATER

6

DRAIN VACUUM
BREAKER, LEAVE
OPEN

CONDENSATE
PUMP
(IF REQUIRED)

NEUTRALIZING
UNIT
(IF REQUIRED)

DRAIN
INSIDE
BUILDING

PLASTIC
TUBING

Figure 7. Condensate disposal system

2. CONDENSATE REMOVAL SYSTEM
The Bobcat B-120 and B-200 boilers are equipped with
a built-in condensation drain and trap. The trap must be
filled with water. DO NOT operate the boiler without filling the trap with water to prevent flue gas discharge into
space. Periodic inspection should be made of this
assembly for deterioration of the tubing and to insure
that the trap is not plugged. If it is plugged or appears to
have excessive sediment in it, it should be removed
from the drain assembly, straightened out to clear the
obstruction, reformed, filled with water and reinstalled
as before. (See Figure 7).
Leave the top of the condensate drain tee open, to act
as a vacuum breaker. Do not allow any part of the
condensate removal system to be exposed to freezing
temperatures, or any other conditions that could cause
blockage.
If a neutralizing system is installed, the filter medium will
require periodic changing, to ensure it’s effectiveness.
Refer to the neutralizing unit’s manufacturers instructions, if available, or change the medium on an annual
basis.
3. PIPING INSPECTION
Look at all water piping. There should be no leaks or
signs of leaks at any pipe joints or around the boiler.

about 12 to 15 psi pressure when temperature is about
70 to 100F and from 15 psi to 25 psi when temperature
is up to 195˚F. FOR YOUR SYSTEM, there is one
correct pressure for each temperature. ASK YOUR
INSTALLER OR SERVICEPERSON TO EXPLAIN AND
SHOW YOU. Learn what normal pressure to look for. If
pressure increases from normal, the relief valve will
open to relieve the pressure. Call your service organization if pressures are higher or lower than normal, and if
the relief valve spills water. Repair or adjustment is
needed.
5. UNUSUAL NOISE
Stand near the boiler and look and listen. As the burner
start and shut off, there should be no unusual noise.
6. BOILER ROOM AIR SUPPLY
Ample boiler room fresh air is required for combustion
(non-direct vent installation) and ventilation (direct-vent
installation).
Check air vents for continues positive supply of air as
required. Air needs are greatest in cold weather if boiler
installation is non-direct vent method. Air vents must be
open and free of obstruction.
Warning: The flow of combustion and ventilating air to the
boiler should not be obstructed.

4. SYSTEM WATER PRESSURE INSPECTION

Warning: If you find any problem during your inspection, call

The boiler water pressure is indicated on the pressure
gage (See Figure 1 for location). The boiler water outlet
temperature is normally indicated on the temperature
display (See Figure 1 for location and Figure 9 for digits
illustration). For most installations, it should indicate

for service immediately.

Bobcat Model B-120A and B-200A

7
The combustion air supply must not be susceptible to
contaminants, which may cause corrosion or other
damage to the heat exchanger and components of the
boiler, causing failure of these parts or unsafe
operation.
Below is a list of products which must be avoided from
being stored or entering the boiler room or air supply
area:
PRODUCTS TO AVOID
•
•
•
•
•
•
•
•
•
•
•
•
•

Spray cans containing chloro/fluorocarbons
Permanent wave solutions
Chlorinated waxes/cleaners
Chlorine-based swimming pool chemicals
Calcium chloride used for thawing
Sodium chloride used for water softening
Refrigerant leaks
Paint or varnish removers
Hydrochloric acid/muriatic acid
Cements and glues
Antistatic fabric softeners used in clothes dryers
Chlorine-type bleaches, detergents and cleaning solvents
found in household laundry rooms.
Adhesives used to fasten building products and other
similar products.

ANNUAL SERVICE AND GENERAL MAINTENANCE
A trained and qualified service technician should
perform inspection and general maintenance listed in
Installation and Operating Instructions (Publication No.
B-40) before each heating season and at regular
intervals.
WARNING: If you do not follow these instructions exactly, a
fire or explosion may result causing property damage,
personal injury or loss of life.

SAFETY AND OPERATING INSTRUCTIONS
Follow the lighting instructions in this manual. These
instructions are also attached to the boiler.

C. Use only your hand to turn the gas supply shut off
valve. Never use tools. If the supply shut off will not turn
by hand, don’t try to repair it, call a qualified service
technician. Force or attempted repair may result in a
fire or explosion.
D. DO NOT use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
OPERATING INSTRUCTIONS
1.
2.
3.
4.
5.
6.

7.
8.

STOP! Read the safety information above.
Set the thermostat to lowest setting.
Turn off all electric power to the appliance.
This appliance is equipped with an ignition device
which automatically lights the burner. Do not try to light
the burner by hand.
Open the gas supply shut off valve, by turning the
handle to be parallel to the gas piping. (See Figure 8).
Wait five (5) minutes (longer for propane) to clear out
any gas, then smell for gas, including near the floor. If
you then smell gas, STOP! Follow “B” in the safety
information above on this page. If you don’t smell gas,
go to next step.
Turn on all electric power to the appliance.
Set thermostat to desired setting.
If the appliance will not operate, follow the instructions
“To Turn Off Gas to Appliance” and call your service
technician or gas supplier.
To Turn Off Gas to Appliance

1. Set thermostat to lowest setting.
2. Turn off all electric power to the appliance if service
is to be performed.
3. Close the gas supply shut off valve, by turning the
handle to be perpendicular to the gas piping.
(See Figure 8).

SAFETY INFORMATION
For Your Safety Read Before Operating

A. This appliance does not have a pilot. It is equipped with
an ignition device which automatically lights the burner.
Do not try to light the burner by hand.

TURN 90˚
TO OPEN

B. BEFORE OPERATING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch: do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.

TURN 90˚
TO CLOSE

GAS SUPPLY SHUTOFF VALVE
IN “OPEN” POSITION

Figure 8.

GAS SUPPLY SHUTOFF VALVE
IN “CLOSED” POSITION

Bobcat Model B-120A and B-200A

8
3. While “t” is blinking, DHW tank temperature may be
set to desired temperature (if tank is equipped with
sensor). The setting range is between 104˚ to 185˚F.

Removing Jacket Front Panel
1. Turn black screws ⁄4 turn to open position.
2. Remove front panel.
To replace the panel, reverse procedure.
1

INTEGRATED BOILER CONTROL
The integrated boiler control monitors the status of the
room thermostat, high limit switch, low water cutoff (if
installed), water inlet and outlet sensors, flue gas sensor
and flame sensor. It controls the operation of the circulator, combustion blower, gas valve and spark ignitor. The
boiler control also determines the sequence of operation
and timing for pre and post purge periods, trial for ignition
and lock out.
The control display board provides information on boiler
operation on a mode and temperature display and can be
viewed, programmed and reset with specific push buttons.
Diagnostic information is also provided on the display, to
help determine the cause of boiler failure. (See Figure 9).
BOILER CONTROL AND DISPLAY FEATURES
(See Figure 9)

4. View actual following temperatures on
“Temperature Display”, Press “Select” button
for selection:
a. Supply water temperature – Select #1 on
“Mode Display”.
b. Return water temperature – Select #2 on
“Mode Display”.
c. Domestic hot water tank temperature (if tank
equipped with sensor) – Select #3 on
“Mode Display”.
d. Flue gas temperature – Select #4 on
“Mode Display”.
e. Outside temperature (if outside sensor is used)
– Select #5 on “Mode Display”.
C. Display Board Pushbuttons:
1. Reset - Used to clear a Lockout Error
(indicated with an “A” in the “Mode Display”)
2. Select - Used to scroll through the modes in the
“View and Changing Temperatures” and
“Viewing and Changing System Setting” menus.

A. BOILER OPERATION STATUS: “Mode Display”
shows status of boiler operation. (See Table 1).
B. VIEW AND CHANGING TEMPERATURES: Setting
boiler supply water temperature and water tank
temperatures (See Table 2).
Press “Select” button for viewing following different
modes on “Mode Display”
1. While “c” is blinking, boiler supply water
temperature for space heating may be set to
desired temperature. The setting range is between
90˚ to 185˚F.
2. While “d” is blinking, boiler supply water temperature for DHW may be set to desired temperature.
The setting range is between 104˚ to 185˚F.

3. Enter - Used to store values that are changed in
the “View and Changing Temperatures” and
“Viewing and Changing System Setting” menus.
4. Up - Used to increase values in the “View and
Changing Temperatures” and “Viewing and
Changing System Setting” menus.
5. Down - Used to decrease values in the “View and
Changing Temperatures” and “Viewing and
Changing System Setting” menus.

“TEMPERATURE”
DISPLAY
(3 DIGITS)

“MODE”
DISPLAY

MODE

“UP”
PUSH BUTTON

TEMPERATURE

“BURNER STATUS”
STEADY DOT = BURNER ON
BLINKING DOT = BURNER OFF
“DOWN”
PUSH BUTTON
RESET
“RESET”
PUSH BUTTON

Figure 9. Display Board

SELECT

“SELECT”
PUSH BUTTON

ENTER
“ENTER”
PUSH BUTTON

Bobcat Model B-120A and B-200A

9

Table
Table11
Table 1
Table 1
Table 1Table 2

Bobcat Boiler Display Board
“Boiler Operation Status”

Table
Table33
Table 3
Table 3
Table 1
Table 3
Mode

Display

Table 3

Description & Temperature Display
Boiler is on stand-by mode.
Temperature display shows supply water Temp.
Space heating mode.
Temperature display shows supply water Temp.
Domestic hot water mode.
Temperature display shows supply waterTemp.
Frost protection mode.**
Temperature display shows supply water Temp.
Lockout (Alarm) condition.
Temperature Display indicates the lockout code
Reset button must be pressed to resume normal operation.
Error Condition. *
Temperature display indicates the error code.
Warning Condition. ***
Temperature display indicates the error code.

Table 1

Note:
Blinking dot on “Mode Display” indicates active heating control, burner off. Steady dot
indicates burner is on.
*: Error must be corrected to resume boiler operation. Pressing the “Reset” button is not
required.
**: The boiler circulator is energized, when boiler water temperature drops below 50˚F.
***: Error must be corrected to resume DHW operation. Space heating not affected.
Pressing the “Reset” button is not required.

Bobcat Model B-120A and B-200A

10

Table 2: Viewing and Changing Temperatures
Press “Select” button for viewing different modes on “Mode Display”

Table 2

Mode
Table 1
Display

Table 2

Table 1

Table 2

Table
1
Blinking

Table 2

Table 1

Table 2

Table 1

Table 2

Table 1

Table 2
Table 2

Table 1
Table 1

Description
Table
3

& Temperature Display

Table
3
Space
heating
supply water temperature could be
changed by pressing “Up/Down” button. Settable from
3
90˚F to Table
185˚F
(steps of 1 F). The default valve is 176˚ F
Press “Enter” button to store. (see note 1)

Blinking

Domestic hot water supply temperature could be changed
by pressing “Up/Down” button. Settable from
104˚F to 185˚F (steps of 1 F). The default valve is 176˚ F
Press “Enter” button to store.
Table 3
(see note 2)

Blinking

Domestic hot water tank temperature could be changed by
Table 3
pressing “Up/Down” button. Settable from 104˚F to 160˚F
Table 3
Table 3 (steps of 1 F). The default valve is 140˚ F.
Press “Enter” button to store. (see note 3)

Table 3

Temperature display shows actual
supply water temperature.
Temperature display shows actual
return water temperature.
Temperature display shows actual DHW tank temperature.
(if the water tank is equipped with sensor)
Temperature display shows actual flue gas temperature.
Temperature display shows actual outside temperature.
(boilers with outdoor sensor)
Table 2

Notes:
1. For space heating mode “0” (boilers not utilizing outdoor sensor)
2. For DHW mode “2” (storage tank with Aquastat)
3. For DHW mode “1” (storage tank with sensor)

Bobcat Model B-120A and B-200A

11
DIAGNOSTIC ERROR CODES
WARNING:
If an operational problem has occurred, the boiler will
shut off and show an “A”, “E” or “H” in the mode display,
along with an error code in the temperature display.
Do not attempt performing any service under these
conditions, but do note the mode and temperature display indication, in case the problem clears itself. An “A”
indication error can be cleared by pressing the reset
button once, which will allow re-try of operation. Do not
repeatedly press the reset button in this case, or if an
“E” or “H” indication error is displayed. Call a trained,
experienced service technician to troubleshoot and correct the problem. The Bobcat Installation and Operating
Instructions, publication B-40 contain a full troubleshooting section for this. Turn off all electric power ot the boiler before service.
A. LOCKOUT ERRORS:
Indicated by an “A” in the mode display. The reset
button must be pressed to clear the error and retry
operation. The temperature display shows the error
code.

ERROR
CODE

INDICATION

01

Water Outlet Sensor Open

02

Water Inlet Sensor Open

03

Flue Gas Sensor Open

11

Water Outlet Sensor Shorted

12

Water Inlet Sensor Shorted

13

Flue Gas Sensor Shorted

19, 42,
45, 46,
47, 48

Control Failure

20

Flame Detected at Wrong Time

21

Polarity Error

22

Frequency Error

24

Earth Connection Faulty

ERROR
CODE

INDICATION

30

Excess Flue Temperature

01

Ignition Failure - 3 unsuccessful ignition
attempts in a row

31

Low Water Cutoff Error

32

Excess Water Inlet Temperature

02

Flame Failure - 3 losses of flame signal
during one demand

51

Reset Button Error

03

Water High Limit Open

52

Boiler Model Selection Error

04, 05, 09,
10, 12, 13,
14, 15, 16,
18, 32

Control Failure

19, 20

Flame Detected at Wrong Time

33

Fan Failure - RPM Error

B. BLOCKING ERRORS:
Indicated by an “E” in the mode display. Operation is
automatically restored, once the condition returns to
normal or is fixed. The temperature display shows
the error code. Pressing the “Reset” button is not
required.

C. WARNING ERRORS:
Indicated by an “H” in the mode display. Operation
of the space heating mode is not affected, and the
warning is displayed intermittently. Operation of the
DHW mode is automatically restored, once the
condition is fixed. The temperature display shows
the error code. Pressing the “Reset” button is
not required.
ERROR
CODE

INDICATION

04

Domestic Hot Water Tank Sensor Open

14

Domestic Hot Water Tank Sensor Shorted

©Slant/Fin Corp. 2008

SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 • Phone: (516) 484-2600
FAX: (516) 484-5921 • Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario
www.slantfin.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Create Date                     : 2008:11:04 16:24:08Z
Creator Tool                    : QuarkXPress(tm) 6.52
Modify Date                     : 2008:11:04 16:27:29-05:00
Metadata Date                   : 2008:11:04 16:27:29-05:00
Producer                        : QuarkXPress(tm) 6.52
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments
Format                          : application/pdf
Document ID                     : uuid:7777b0d8-aab7-11dd-a269-001f5b3ac108
Instance ID                     : uuid:7777c7b2-aab7-11dd-a269-001f5b3ac108
Page Count                      : 12
Creator                         : QuarkXPress(tm) 6.52
EXIF Metadata provided by EXIF.tools

Navigation menu