Slant Fin Kicker Tk 70 Users Manual
Kicker TK-90 120
TK-70 to the manual e036a64b-5ecb-b1f4-0926-fd93c387030a
2015-02-05
: Slant-Fin Slant-Fin-Kicker-Tk-70-Users-Manual-407018 slant-fin-kicker-tk-70-users-manual-407018 slant-fin pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Multi-purpose fan convection heater Kicks up the hydronic heat in hard to heat places. • KICK SPACE • RECESSED WALL MOUNT • SURFACE WALL MOUNT When there’s not enough wall space to install baseboard radiation, install The Kicker by Slant/Fin. The compact Kicker provides the heat output of up to 12 feet of baseboard, depending on the model you choose. Sized to fit under cabinets or between wall studs, The Kicker is simple to install and easy to operate. Set it and forget it The Kicker is generally installed in series with baseboard or other radiators that make up a heating zone. An aquastat inside The Kicker activates The Kicker’s fan so that it automatically turns on and off, delivering a quiet flow of heat to the room whenever the radiators in the heating zone are hot. A convenient switch enables the user to set the fan speed at high, low or off. The Kicker may also be installed as a separate zone with its own room thermostat. Routine cleaning is the only maintenance The Kicker should require. Unique manifold heat exchanger provides better performance The unique manifold-type heat exchanger of The Kicker provides higher heat output while minimizing friction loss. The supply water in each of the short loops off the manifold makes just a single pass through the heat exchanger. This provides higher supply water temperature to a greater percentage of the heat exchanger fins than a serpentine coil. Since this configuration helps minimize pressure drop, you can often install The Kicker in the same heating loop with baseboard, without diverting tees. That reduces installation costs. Competitive units use a less efficient serpentine loop heat exchanger. The supply water cools as it flows from one end of the long loop to the other,reducing heat output. The two Kicker models, TK-70 and TK-90, are packaged for kick space installation. The output varies by model but the physical dimensions are identical. Accessory kits are available to install The Kicker in a recessed wall mount or surface wall mount application. Each kit includes the additional cabinet, grille and hardware necessary for these installations. The Kicker outperforms the competition Although several kickspace heaters have been on the market for a number of years, there has been no industry standard for establishing their ratings. The Hydronics Institute is currently evaluating test procedures that would permit all kickspace heaters to be rated under common IBR test conditions. Slant/Fin followed one of the proposed test procedures to establish its ratings. In its own tests, Slant/Fin found The Kicker to have higher output than competitive units that it tested. ® by HIGH PERFORMANCE HEATING FOR HARD TO HEAT AREAS Design features help ensure long life and reliable operation. 2 3 7 8 11 1 9 5 4 4 5 6 6 2 10 7 3 8 1 9 2 10 12 13 11 12 13 Water Flow CFM GPM Model TK-90 With SMK or RMK Wall Mount Kit 81 TK-90 Kickspace 68 TK-70 With SMK or RMK Wall Mount Kit 72 TK-70 Kickspace 60 WATER PRESSURE DROP (FEET W.C.) Models GPM TK-90 TK-70 1 0.32 0.34 2 1.30 1.40 3 2.80 3.00 3 2 1 3 2 1 3 2 1 3 2 1 High performance manifold-type heat exchanger. Two built-in air vent tappings. Coin or screwdriver access. Brazed tube joints resist rigors of installation and years of operation. 1/2" hot water supply and return fittings. Aluminum turbo fin heat exchanger maximizes heat transfer. Expanded copper tube bonds fin to copper for high heat transfer. Heavier duty 2-speed blower motor for extended life. Internally cooled. Permanently lubricated. Tangential aluminum blower. Aquastat permits blower operation only when the water temperature is above 130°F. Three-position blower switch is easily accessible. Hot dipped galvanized chassis resists rust and corrosion. Rubber grommets cushion chassis for quiet operation. 22" matte black grille separates heated air from intake air for better performance. HOT WATER RATINGS (BTUH) 140° 160° 180° 5154 4894 4005 4437 4250 3584 4269 4094 3658 3721 3616 3267 6958 6660 5616 5914 5698 4925 5456 5285 4753 4684 4559 4171 8715 10465 12216 8390 10111 11839 7227 8839 10450 7350 8770 10218 7118 8519 9941 6266 7607 8948 6632 7805 8979 6428 7576 8722 5849 6944 8039 5638 6601 7558 5501 6440 7386 5075 5979 6883 200° 220° 3 YEAR LIMITED WARRANTY The Kicker comes with a 3-year limited warranty against defects in materials and workmanship. Complete warranty details available upon request. Kickspace Locations No separate kit required 153⁄8" 171⁄16 4" 241⁄4" 2515⁄16" Ratings are BTU per hour with 65° entering air. Blower motor voltage: 120 VAC, 60 Hz. TK-90---0.72 F.L.A., 41 Watts TK-70---0.62 F.L.A., 37 Watts Recessed Wall Mounted Requires Kit RMK Surface Wall Mounted Requires Kit SMK ©Slant/Fin Corp. 1994. Printed in the U.S.A. 101. Publication No. TK-10. SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 • Phone: (516) 484-2600 FAX: (516) 484-5921 • Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario www.slantfin.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-701 About : uuid:ad34340f-46d3-11d8-94f1-0030656cfbcc Producer : QuarkXPress(tm) 6.0 X Press Private : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%DocumentCustomColors: (Blue).%%+ (Red).%%+ (New Color).%%CMYKCustomColor: 1 .7 0 0 (Blue).%%+ 0 .996 .988 0 (Red).%%+ 0 .39 1 0 (New Color).%%EndComments Create Date : 2004:01:13 14:23:35Z Creator Tool : QuarkXPress(tm) 6.0 Modify Date : 2005:11:30 14:58:15-05:00 Metadata Date : 2005:11:30 14:58:15-05:00 Document ID : uuid:a46d8d14-46d3-11d8-94f1-0030656cfbcc Instance ID : uuid:a52882b4-61db-11da-b1fa-0030656cfbcc Format : application/pdf Page Count : 2 Creator : QuarkXPress(tm) 6.0EXIF Metadata provided by EXIF.tools