Smarfid Security Equipment REX2110EIS Contactless Door Egress Device (US Standard) User Manual
Shanghai Smarfid Security Equipment Co, Ltd. Contactless Door Egress Device (US Standard) Users Manual
Users Manual
Contactless Door Egress Device (US Standard) Design Philosophy Match OEM reader design in order to maximize the marketing value at the door. Abbreviation REX2-e – Economic Request to Exit button. Basic model without chimer and sirens. REX2-i – Intelligent Request to Exit button. Model with chimer and sirens. REX2-s – Safety Request to Exit Device. Model with Break Glass function. Technology & Function Capacitance Proximity Technology has been used instead of Infar-red technology – environmental independent design. When the device is activated, indicator light will change color with an audible tone – very user friendly. Icon indicators to alert the user for Door Held Open, Fire Alarm and Mains Failure situation. Build-in Mechanical Override in case power failure or electronic failure. Build-in Door Chimer to interact with the “*” sign on Magic series Number pad reader. Build-in Fire Alarm input. If the fire input got trigger, the lock will be released automatically. Embedded a traditional Break Glass device with “test key”. When activated, both Visible and Auditable alert will trigger to provide better indication of the door location under emergency situation. Support Remote Control (433MHz) to trigger the REX remotely. Friendly Installation All input and output signals are All inputs are 12Vdc protected. protected against static charges. Reverse power protection. Specification: Model REX2-i Functions REX2-s Functional Specification Color changes from Blue to Green with a beep Request to Exit indication Request to Exit output Dry contact output for 1 seconds (NC/NO selectable) RTE Output (dry contact) NC/NO jumper selectable rated @ 30Vdc; 1A Mechanical Override Available for all models Tamper protection Available for all models 433.896MHz Remote Button (Optional) (Max supports 5 remote buttons at the same time.) Alarm Output Dry contact output follow the Fire input (NC/NO selectable) Door Held Open The icon will change to blue and beep every 5 seconds Indication icon Door Held Open High/Low level input High/Low level input jumper selectable jumper Buzzer for DHO and RTE Jumper enable/disable activate Main Power failure Mains failure dry contact output from Power Supply. Indicator The icon will change to orange when activated Fire Alarm Indicator Fire Alarm Input The icon will change to red and siren will activated When trigger, back lit will flash in Red the siren will When trigger, the lock will release and back activate lit will flash in Red & siren will activate Speaker Equipped for Door Chimer and Siren “Break Glass” function N/A Dimension 118.2 (L) X 74.2 (W) X 8.5 (H) mm (above surface) Hit hard at the center Technical Specifications Typical Read range ~3 to 4cm N/A Electric Lock bypass relay Electric Box 30Vdc; 2A (max) Please make sure the gang box is similar to the diagram as display. Requirement Weight 157g Operating Specification: Operating Voltage 9 - 15VDC Operating Current 150mA (max @ 12Vdc) Operating Temperature -20℃-60℃ Case material Standard Color Operating Humidity PC+ABS Black & White 10% - 90% FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Bernard Chiang Create Date : 2014:01:26 10:31:06+08:00 Modify Date : 2014:03:28 09:53:12+08:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2014:03:28 09:53:12+08:00 Creator Tool : Adobe Acrobat Pro 9.0.0 Format : application/pdf Creator : Bernard Chiang Document ID : uuid:5e2d78cc-5ce0-4b79-ae03-c8e5da380c7d Instance ID : uuid:063542d0-43ea-4290-a94c-84a0b2de387f Producer : Adobe Acrobat Pro 9.0.0 Page Count : 3EXIF Metadata provided by EXIF.tools