Smarfid Security Equipment SSHR35 Slender Series 125 kHz Reader User Manual 15020079

Shanghai Smarfid Security Equipment Co, Ltd. Slender Series 125 kHz Reader 15020079

15020079_User manual

Download: Smarfid Security Equipment SSHR35 Slender Series 125 kHz Reader User Manual 15020079
Mirror Download [FCC.gov]Smarfid Security Equipment SSHR35 Slender Series 125 kHz Reader User Manual 15020079
Document ID2543354
Application IDS0hanjE6pfT6pMi7KudN4g==
Document Description15020079_User manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize79.2kB (990035 bits)
Date Submitted2015-03-01 00:00:00
Date Available2015-03-02 00:00:00
Creation Date2015-01-23 13:41:24
Producing SoftwareAcrobat Distiller 9.2.0 (Windows)
Document Lastmod2015-01-23 13:41:24
Document TitleE:\Anna\跟进项目\南京\周晨\15020079\Tech files\CE NB\TCF\FCC 125KHz Slender Series 20130625 En.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: Administrator

125KHz Slender Series Reader
Design & Technologies
Support reader to read either EM or HID cards.
Economical mullion mounts type.
Support on-site Reader Configuration Card to
Design with customer logo is possible.
change certain parameters.
Door Bell function for Number pad reader.
Tamper protection
Number pad use “touching sensor”, the latest
Easily see under dark environment.
technology and individual number backlit when
Could be use as a door location
touch.
Friendly Installation
“Touch” number pad does not
Universal back plate allows
carry any moving parts, which
the reader be installed on
implies more durable.
different size of gang box.
All weather proof design with
Non-drop bottom screw made
Stainless steel Security
IP65 certificate.
servicing handier.
screw is an option
All inputs are 12Vdc
protected.
All input and output signals are
protected against static
charges.
Reverse power protection.
FCC Caution.
§ 15.19 Labelling requirements.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
§ 15.21 Information to user.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority
to operate the equipment.
§ 15.105 Information to the user.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
Model Number: X1 X2 N1 N2 N3 – N4 X3
RF Technologies
X1X2
HR = 125KHz
Reader Appearance and Function
N1
3 = Normal Reader
N2
5 = Normal Reader
N3
2 = Read UID / Card Number
N4
8 = Pigtail
X3
N = No Number pad; K = Number pad
Model
Functions
Standard Reader
Keypad Reader
Configurable Functions
Re-configure Window
5 seconds (Default) or Half an hour after Power up
Reader Output Format
CSN/UID 32bits, 34bits, 56bits (backward/forward), file content reading for programmed ID
Wiegand Plus Width
Keypad Output
Buzzer Control
LED/Back lit Control
Different choices to fit with different Controller’s requirements
N/A
Definable
Reader & Controller control (Default) or Controller control only
Define different LED color response base on Green LED
Technical Specifications
Typical Read range
>5 cm (Base on different technology)
Reader Standard Output
Wiegand (RS232 & RS485 optional)
Standard Keypad output
N/A
Wiegand with 4 bits burst
Wiring Distance
150m (22 AWG with shielded cable)
Wiring Distance
125KHz
Operating Specification::
Operating Voltage
10 - 15VDC
Operating Current
150mA (max)
Operating Temperature
Exterior dimension
Case material
Standard Color
Operating Humidity
Weight
-30℃-70℃
150*53*25 mm
PC+ABS
Black
10% - 90%
180g

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Administrator
Create Date                     : 2015:01:23 13:41:24+08:00
Modify Date                     : 2015:01:23 13:41:24+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Creator                         : Administrator
Title                           : E:\Anna\跟进项目\南京\周晨\15020079\Tech files\CE NB\TCF\FCC 125KHz Slender Series 20130625 En.doc
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.2.0 (Windows)
Document ID                     : uuid:81b5c61e-738b-49dc-a5d7-e11b731b15ad
Instance ID                     : uuid:e62be854-bcf4-492e-acdc-e3157d84548a
Page Count                      : 3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: X3A-SSHR35

Navigation menu