Smart Technologies and Investment SMARTECRF1252R 900MHz Transceiver of Intercom Unit User Manual New Intercom Instrs indd

Smart Technologies & Investment Ltd 900MHz Transceiver of Intercom Unit New Intercom Instrs indd

User Manual

Download: Smart Technologies and Investment SMARTECRF1252R 900MHz Transceiver of Intercom Unit User Manual New Intercom Instrs indd
Mirror Download [FCC.gov]Smart Technologies and Investment SMARTECRF1252R 900MHz Transceiver of Intercom Unit User Manual New Intercom Instrs indd
Document ID603040
Application ID9S803cH11vrjBDSguSHmHw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize48.93kB (611659 bits)
Date Submitted2005-11-16 00:00:00
Date Available2005-11-16 00:00:00
Creation Date2005-02-14 12:05:01
Producing SoftwareAdobe PDF Library 6.0
Document Lastmod2005-04-06 17:57:28
Document TitleNew Intercom Instrs.indd
Document CreatorAdobe InDesign CS (3.0.1)

Wireless Gate Entry Intercom/Keypad
Instructions for Wired and Wireless Installations
Thank you for purchasing the GTO Wireless Gate Entry
Intercom/Keypad. Be sure to read the directions carefully and
completely. Before permanently mounting the keypad, please
program the keypad and test its range.
IMPORTANT: Your intercom/keypad may need to be hard
wired due to the fact that it must accept interference according to FCC regulations listed below. For example, applications that are relativity close to cell towers or airports may
receive intermittent interference and require hard-wiring.
As a wireless intercom/keypad it can be used with any gate
opener that receives a 318 MHz RF signal.
SAFETY NOTE: Never install the keypad portion of this unit
where a person can reach through the gate to activate it, or
where a person can touch the gate while activating the keypad. The recommended minimum distance between the gate
and keypad is 10 ft.
FCC WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in particular installations. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •
Reorient or replace the receiver antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.
Features of the Intercom/Keypad
The intercom/keypad has two separate units. The outside unit should be mounted outside the gate allowing the driver of the vehicle
approaching the property to press the CALL button from their vehicle and the inside unit with it’s rechargable battery can be plugged
into any 110 Volt AC outlet for use while charging or it can be disconnected form the electrical cord allowing it to go anywhere within
range for convenience.
When someone without an access code approaches the gate they will press the CALL button on the outside keypad unit which will
ring the inside unit. To answer the CALL, the person inside presses and holds the ANSWER button to talk to the person at the gate,
releasing the ANSWER button it to listen. To allow the person calling to open the gate the GRANT PERMISSION button must be
pressed then the person at the keypad can press any key to open the gate.
Up to 25 different personal entry codes may be programmed into the outside keypad, allowing you to give different entry codes to different users. For example, you can give a delivery person their own entry code, which you can easily change after they have made the
delivery. This will prevent them from being able to regain access, while still allowing those to whom you gave other entry codes full
access.
After entering a valid code, pressing any key while the gate is opening will stop the gate; pressing any key while the gate is stopped
and the gate will reverse direction. The keypad will not affect the auto-close setting of your gate opener system.
The keypad face will light up and beeper will beep at the press of any key. The keypad memory will recognize your entry code in a
string of up to 20 digits; if it finds the correct sequence it will activate the gate opener. As a security feature, the keypad will shut down
for 40 seconds if it does not find the correct code sequence within a 20 digit string. This will discourage an unauthorized person from
trying to use random numbers to access your property.
Your entry codes will remain stored in memory even when the batteries go dead. The keypad will remember your entry codes as long
as you don’t press the RESET button.
rev - 02-28-05
©2005 GTO, Inc.
Keypad Description
Keypad - Front
�������
�
�
���
�
���
�������
�
���
�
���
�
���
�
���
�
���
�
���
�
������
�������
����
CALLING Light:
LED is RED when calling and turns
GREEN when call is answered.
GRANTED Light:
LED turns GREEN when access
permissiom is granted.
PROGRAM button:
Used to program access codes.
STATUS Light:
This led will blink once when any
key is pressed and provides visual
feedback during access code
programming.
Keypad - Inside
�
�
�
���������
������
�����
������
�����
��������
������ �����
� � � �
� � � �
Installing Batteries
NOTE: 3 AA batteries are required to power the keypad unless an external
power supply such as the gate openers power source is used. Low voltage
wire from the external power source must be connected to the POWER IN
terminals on the keypad control board, if batteries are not installed.
Step 1: Remove the two screws from the bottom of the keypad and separate the keypad from its housing.
Step 2: Install 4 AA batteries (not included).
DIP Switches:
Match these switches to your remote
transmitter to program the keypad.
Power Input:
Used to connect power supply (8-24 Vac/dc)
when using outside power source.
Relay output:
Used to connect Keypad to gate opener in
hard-wired applications.
RESET button:
Pressing this button for 2 seconds will
reprogram key pad to factory settings. All
codes are deleted. Default master code is 1234.
ID SET button:
This button is used only in the situation where
there is another pair of GTO wireless intercom units nearby causing interference.
Battery Holder:
Use 4 AA batteries if hard-wired power supply
is not used. If external power source is used the
4 AA batteries will provide a back-up power
source.
Wireless Installation of the Keypad
NOTE: For wireless applications, the distance from the keypad to the opener’s receiver should not exceed 50 ft. Always test the keypad
range before permanently mounting it.
Step 1: Mount the keypad cover using the screws provided. Set the keypad
DIP switches to match your entry transmitter’s DIP switch settings.
–
123456789
NOTE: If you have not changed your opener’s
transmitter code from the factory setting, see
the “Setting Your Personal Transmitter Code”
section in the gate openers manual then set
the keypad DIP switches to match the new
transmitter DIP switch setting.
ABC
GHI
JKL
PRS
TUV
DEF
MNO
WXY
Step 2: Slide the keypad into the cover and secure with the small screws
provided.
Wired Installation of the Keypad
NOTE: If you also plan to power the keypad with the gate opener’s power source, run two pairs
of wires as described below. One pair to hard-wire the keypad and the other pair to connect the
keypad to the gate opener’s battery.
Step 1: Turn the gate opener’s power switch OFF. Use 16 gauge, stranded, direct burial low
voltage wire (part no. RB509) to connect the keypad to the opener control board. Run wire
through PVC pipe from the ground to keypad and from the ground to the opener control board
to protect the wire from lawn mowers or grazing animals.
Determine how the wire will enter the keypad (i.e. from the back through a hole drilled in the
mounting post or running the wire on the surface of the post). Remove the small rectangular
knock-out on the back of the keypad cover and pull the wire into the cover. Then mount the
cover to the post using the screws provided.
Knock-out
Step 2: To hard-wire the keypad - strip the wires back 3/16” and attach the wires to the terminal
block marked RELAY OUTPUT on the keypad control board as shown to the right. Connect the
other end to the opener’s control board as shown in Control Board Connections section below.
–
To wire the power supply to the keypad attach the wires to the AC/DC POWER IN terminal
on the keypad control board as shown to the right. Connect the other
end to the opener’s battery - one end to the POSITIVE pole and the
other to the NEGATIVE pole.
Step 3: Slide the keypad into the cover
and secure with the small screws
provided.
GHI
PRS
ABC
JKL
TUV
RELAY
OUTPUT
Jumper ON
Jumper OFF
NOTE: For a hard-wired application the jumper between the
two terminals on the keypad control board must be connected
(ON) as shown. This will disable the 318 MHz RF transmitter.
123456789
#1
AC/DC
POWER IN
Power Supply from
Opener Battery
#2
Hard-wire from Gate Opener
Step 4: With the power to the opener turned
OFF. Remove opener control board cover and feed enough of the low voltage keypad wire through a strain
relief to reach the gate opener control board terminals.
DEF
MNO
WXY
Step 5: Attach the wires from the keypad to the opener control board terminal blocks as shown below.
Step 6: Replace the control board cover and turn the power switch ON. Test the keypad by entering 1 2 3 4.
Step 7: Program your ‘Personal Master Code’ and any additional entry codes (for a total of 25 entry codes)
you wish. See Programming the Keypad section.
Control Board Connections
NOTE: If your control board doesn’t look like any of these diagrams, please call GTO Technical Service at 1-800-543-1236
or 850-575-4144 for additional support.
Mighty Mule 350 Control Board
Mighty Mule 250 E-Z Gate Opener
Control Board
15 AMP
GTO/PRO DC Powered PRO-SW3000
and PRO-SW4000 Control Boards
BLK
GRN
COMMON
RED
OPEN
EDGE
CLOSE
EDGE
SHADOW
LOOP
EXIT/
OPEN
SAFETY
CYCLE
CLOSE
RED
OPEN
EDGE
GTO
RCVR.
OPEN
CLOSE
FIRE DEPT.
SHAD. LOOP
SAFE LOOP
ENTRY LOOP
CYCLE
FREE EXIT
BLK
COMMON
CLOSE
EDGE
#1
COMMON
EXIT
OPEN
#2
COMMON
SHADOW
LOOP
Connect #1 wire from the
RELAY OUTPUT terminals on
the keypad to CYCLE terminal on
the gate opener control board.
COMMON
SAFETY
RED
RECEIVER
AUX 2
CYCLE
CLOSE
#2
GTO/PRO AC Powered Operator Control Board
J12
GRN
GRN BLK
24VDC +
ACCES. PWR
–
J8
J11
RECEIVER
TB3
TB4
#1
Connect #2 wire from the
RELAY OUTPUT terminals
on the keypad to the
COMMON terminal on the
gate opener control board.
TB5
#2
TB6
Connect #1 wire from the
RELAY OUTPUT terminals on
the keypad to CYCLE terminal on
the gate opener control board.
TB7
TB8
Connect #2 wire from
the RELAY OUTPUT
terminals on the keypad
to the COM terminal on
the gate opener control
board.
EDGE
#1
Connect #2 wire from
the RELAY OUTPUT
terminals on the keypad
to the COM terminal on
the gate opener control
board.
COM
Connect #2 wire from the RELAY
OUTPUT terminals on the keypad
to the COMMMON terminal on
the gate opener control board.
Mighty Mule 500 & 502
Control Boards
COM COM
COM
RECR
Connect #1 wire from the
RELAY OUTPUT terminals
on the keypad to CYCLE
terminal on the gate opener
control board.
Connect #2 wire from the
RELAY OUTPUT terminals on
the keypad to the COMMON
terminal on the gate opener
control board.
Connect #1 wire from the
RELAY OUTPUT terminals on
the keypad to CYCLE terminal on
the gate opener control board.
#1
#2
CYCLE
EXIT
SET
CLOSE
LIMIT
LEARN
TRANSMITTER
SAFETY
COMMON
CYCLE
EDGE
SAFETY
RED
BLK
GREEN
RADIO
LINK
18 VAC
INPUT
Connect #1 wire from the
RELAY OUTPUT terminals on
the keypad to CYCLE terminal on
the gate opener control board.
#2
#1
Programming the Keypad
Programming Interface:
Program (Add) New Temporary Entry Code:
•
•
•
•
• Press and release PROGRAM button.
• Enter the Master Code then press and release PROGRAM
button.
• Enter 8, and any number between 1 thru 7 then press and
release the PROGRAM button. The second number indicates
the number of days after which the code will be automatically
removed from memory
NOTE: If memory is full (all 25 locations are already
programmed) or an invalid entry is detected then an error
condition has occurred, the STATUS light will flash rapidly
and the beeper will sound for 2 seconds before returning to
normal operation, without saving.
• Enter the new Entry Code then press and release PROGRAM
button.
• Beeper beeps 3 times to confirm that the new Entry Code is
accepted.
NOTE: If the code is NOT 4-digit in length or an error
condition has occurred, the STATUS light will flash rapidly
and the beeper will sound for 2 seconds before returning to
normal operation, without saving.
All codes are four (4) digits in length.
Entry code is a four (4) digit code needed to activate the gate.
Master Code is needed to add, remove or reset entry codes.
Master Code also functions as the entry code under normal
operation.
• Factory default Master Code is 1234.
• STATUS light should blink and beeper should beep (once)
whenever any button is pressed.
• If more than 10 seconds elapsed between key presses the unit
returns to normal (idle) operating mode.
• Keypad can only enter program mode from sleep mode
(keypad is turned OFF).
• Keypad will beep three times before going into sleep mode.
Program New Master Code:
• Press and release PROGRAM button.
• Enter the old Master Code then press and release PROGRAM
button.
• Enter 0, 6 then press and release PROGRAM button
• Enter the new Master Code then press and release PROGRAM
button.
• Enter the new Master Code then press and release PROGRAM
button again for confirmation.
• Beeper beeps 3 times to confirm that the new Master Code is
accepted.
NOTE: If the Master Code is not a matched pair or error occurs
(i.e. if the entry code is NOT a 4-digit code) the STATUS light
will flash rapidly and the beeper will sound for 2 seconds before
returning to normal operation with old Master Code.
Example: Key press sequence to change old Master Code from
1 2 3 4 to 3 1 2 1
1 2 3 4
0 6
3 1 2 1
3 1 2 1
Example: Key press sequence to add “3456” as a new entry
code that will remain valid for 2-days only. (1234 is the
Master Code)
1 2 3 4
8 2
3 4 5 6
The round black dot is the ‘PROGRAM’ button.
Example: Key press sequence to add “3456” as a new entry
code that will remain valid for 7-days only. (1234 is the
Master Code)
1 2 3 4
8 7
3 4 5 6
The round black dot is the ‘PROGRAM’ button.
The round black dot is the ‘PROGRAM’ button.
Delete An Entry Code:
Program (Add) New Entry Code:
• Press and release PROGRAM button.
• Enter the Master Code then press and release PROGRAM
button.
• Enter 0, 3 then press and release PROGRAM button.
• Enter the Entry Code to be deleted then press and release
PROGRAM button.
• Beeper beeps 3 times to confirm that the new Entry Code is
deleted.
• Press and release PROGRAM button.
• Enter the Master Code then press and release PROGRAM
button.
• Enter 0, 2 then press and release PROGRAM button.
NOTE: If memory is full (all 25 locations are already
programmed) the STATUS light will flash rapidly and the
beeper will sound for 2 seconds before returning to normal
operation, without saving.
• Enter the new Entry Code then press and release PROGRAM
button.
• Beeper beeps 3 times to confirm that the new Entry Code is
accepted.
NOTE: If the code is NOT 4-digits in length or an error
condition has occurred, the STATUS light will flash rapidly
and the beeper will sound for 2 seconds before returning to
normal operation, without saving.
Example: Key press sequence to add ‘3456’ as a new entry
code. (1234 is the Master Code)
1 2 3 4
0 2
3 4 5 6
The round black dot is the ‘PROGRAM’ button.
NOTE: If no matching code is found or the code is NOT 4-digit
in length then an error condition has occurred, the STATUS
light will flash rapidly and the beeper will sound for 2 seconds
before returning to normal operation, without saving.
Example: Key press sequence to delete entry code ‘3456’ from
memory. (1234 is the Master Code)
1 2 3 4
0 3
3 4 5 6
The round black dot is the ‘PROGRAM’ button.
Delete ALL Entry Codes:
Normal Keypad operation:
• Press and release PROGRAM button.
• Enter the Master Code then press and release PROGRAM
button.
• Enter 0, 7 then press and release PROGRAM button.
• Beeper beeps 3 times to confirm that the All Entry Codes are
deleted.
• If the user enters a 4-digit code that is matched to one of the
25 stored codes. The STATUS light should blink twice and the
beeper should beep twice to confirm that a matched code is
entered.
• No more than 20 key presses are allowed to obtain the 4-digit
entry code.
Example: Key press sequence to delete all entry codes from
memory. (3121 is the Master Code)
Example:
1234 is one of the codes stored in one of the memory location.
1 2 3 4
0 7
The round black dot is the ‘PROGRAM’ button.
The user can enter ‘x1234’ or ‘xxxxxxxxxxxxxxxx1234’ and
the gate should be activated (x is any key). If more than 20 key
presses is entered without matching one of the codes then the
unit’s STATUS light should be flashing rapidly and no entry will
be accepted for the next 40 seconds. The user must not enter
any code for at least 40 seconds before the unit returns to normal operation; otherwise it remains in this ‘lock-down’ mode.
Once the user enters a matched code, any subsequent key press
within the next 40 seconds will re-activate the keypad.
Keying Indication Summary:
Keying Error Alert Indication
Keying accepted confirmation Indication
Master Code Setting
Speaker: continuous Beep for 2 seconds
STATUS light: rapid flashing
Speaker: Beep – Beep – Beep
STATUS light: no light, no flashing
Permanent Entry Code
Speaker: continuous Beep for 2 seconds
STATUS light: rapid flashing
Speaker: Beep – Beep – Beep
STATUS light: no light, no flashing
Temporary Entry Code
Setting
Speaker: continuous Beep for 2 seconds
STATUS light: rapid flashing
Speaker: Beep – Beep – Beep
STATUS light: no light, no flashing
Entry Code Matching
Speaker: continuous Beep for 2 seconds
Speaker: Beep – Beep – Beep
(after non-matching 20 keying)
STATUS light: no light, no flashing
STATUS light: rapid flashing
Intercom Description
Intercom - Face
POWER Light:
LED is GREEN when charging on AC power source and RED
during battery power mode.
ANSWER Button:
Used to answer CALL from keypad.
HOLD to talk - RELEASE to listen.
DV
9V
1- C
80 ON
0- TR
54 O
3- L S
42 Y
83 ST
An
sw
er
Pe Gran
rm t
iss
ion
Ke
Ba ypa
tt d
Lo
PO
WE
KEYPAD BATTERY INDICATOR Light:
LED turns ON when keypad battery is low.
GRANT ACCESS Button:
The GRANT PERMISSION button must be
pressed then the person at the keypad can
press any key to open the gate.
9 Vdc Transformer Plug:
Transformer plugs here to charge the battery.
Intercom - Bottom
VOLUME Control:
Controls volume level of speaker.
ME
LU
VO
BATTERY ACCESS Cover:
Rechargable 3.6 Volt Ni-Cd battery included.
ET
ID S
ID SET button:
This button is used only in the situation where there is
another pair of GTO wireless intercom units nearby
causing interference.
Intercom Installation
sw
An
TE
1- C
80 ON
0- TR
54 O
3- L S
42 Y
83 S
DV
9V
The intercom can be disconnected from the transformer and
used as a battery powered unit, allowing it to be move to
any convenient location, i.e. bedroom, patio, or garden area.
er
If you are mounting the intercom on the wall use the
template on the last page of this manual to place screws.
Pe Gran
rm t
iss
ion
Ke
Ba ypa
tt d
Lo
PO
WE
Find a convenient location to place or mount the intercom
that is close to a 110 Vac outlet. Plug the transformer into
the AC outlet and connect it to the intercom’s power jack
marked DC 9V.
Testing the System
Have someone press the CALL button on the Keypad at the gate. When the Intercom inside the house rings press press the
ANSWER button and talk to the person at the gate to check the connectiion and range. Then press the GRANT PERMISSION
button and have the person at the gate press any key to open the gate.
NOTE: If any key is pressed while the gate is opening will cause the to stop and pressing any key again will allow the gate to
continue to open.
Limited One Year Warranty
GTO, Inc. gate opener accessories are warranted by the manufacturer against defects in workmanship for a period of one (1) year from the date of
purchase, provided recommended installation procedures have been followed.
In the case of product failure due to defective material or manufacturer workmanship within the one (1) year warranty period, the accessory will be repaired or replaced (at the manufacturer’s option) at no charge to the customer, if returned freight prepaid to GTO, Inc., 3121 Hartsfield Rd., Tallahassee,
FL 32303. IMPORTANT: Call 850/575-4144 or fax 850/575-8950 for a Return Goods Authorization (RGA) number before returning goods to factory.
Products received at the factory without an RGA will not be accepted. Replacement or repaired parts are covered by this warranty for the remainder of
the one (1) year warranty period. GTO, Inc. will pay the shipping charges for return to the owner of items repaired.
The manufacturer will not be responsible for any charges or damages incurred in the removal of the defective parts for repair, or for the reinstallation
of those parts after repair. This warranty shall be considered void if damage to the product(s) was due to improper installation or use, connection to an
improper power source, tampering, or if damage was caused by lightning, wind, fire, flood, insects, or other natural agent.
After the one (1) year warranty period, GTO Inc. or one of its authorized service centers will make any necessary repairs for a nominal fee. Call GTO
at 850/575-4144 for more information. This warranty gives you specific legal rights, and you may also have other rights which may vary from state
to state. This warranty is in lieu of all other warranties, expressed or implied. NOTE: Verification of the warranty period requires copies of receipts or
other proof of purchase. Please retain those records.
If you have any questions or concerns, please contact our Technical Service Department at 1-800-543-1236 or 850-575-4144.
GTO, Inc. • 3121 Hartsfield Road • Tallahassee, Florida 32303
Telephone (850) 575-0176 • Fax (850) 575-8912 • website www.gtoinc.com
The contents of all material available on this installation manual are copyrighted by GTO, Inc. (“GTO”), unless otherwise indicated. All rights are reserved by GTO, and content may not be
reproduced, downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO. Any reprinting of GTO publications is by
permission only. Copyright infringement is a violation of federal law.
GTO®, GTO/PRO®, Mighty Mule® are registered trademarks of GTO, Inc. Professional Access Systems™ is a trademark of GTO, Inc. and are the exclusive property of GTO, Inc. (“GTO”).
All rights are reserved by GTO, and these marks may not be used, in any for without the prior, written permission of GTO.
Hole Template for Mounting the Intercom


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Modify Date                     : 2005:04:06 17:57:28+08:00
Create Date                     : 2005:02:14 12:05:01Z
Trapped                         : False
Creator                         : Adobe InDesign CS (3.0.1)
Producer                        : Adobe PDF Library 6.0
Page Count                      : 8
About                           : uuid:d62e2f97-8cb5-11d9-9e96-0011242e34e8
Creation Date                   : 2005:02:14 12:05:01Z
Mod Date                        : 2005:04:06 17:57:28+08:00
Metadata Date                   : 2005:04:06 17:57:28+08:00
Creator Tool                    : Adobe InDesign CS (3.0.1)
Rendition Class                 : proof:pdf
Document ID                     : adobe:docid:indd:fc0393ff-8012-11d9-93f1-ad777c69dd23
Derived From Instance ID        : 2de6420e-7759-11d9-aceb-e4c696211317
Derived From Document ID        : adobe:docid:indd:9da74016-6f93-11d9-aaf2-819f77028bae
Format                          : application/pdf
Title                           : New Intercom Instrs.indd
EXIF Metadata provided by EXIF.tools
FCC ID Filing: N9KSMARTECRF1252R

Navigation menu