SmartLabs 2475DA1 In-Line Hardwired Light Dimming Module User Manual 2475DA1 Owners Manual

SmartLabs, Inc. In-Line Hardwired Light Dimming Module 2475DA1 Owners Manual

Users Manual

    April 20, 2012  In-Line Hardwired Light Dimming Module Model: 2475DA1 FCC ID: SBP2475DA1 IC: 5202A-2475DA1  The owner’s manual below may be accessed freely via the Internet with any web browser and supports the PDF format. www.smarthome.com/2475DA1.html    Complies with Section 5 of FCC document 784748 D01 Labeling Part 15 18 Guidelines v07 where cautionary statements in the user manual may be provided over the Internet. On-Line Owner’s Manual Containing Cautionary FCC & IC Statements
                                                                 Page 1 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM   In-LineLinc™ Dimmer INSTEON® In-LineLinc Dimmer, Dual-Band  Owner’s Manual (#2475DA1)
                                                                  Page 2 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM  In-LineLinc Dimmer Dual-Band .................................................................................................................3 Features and Benefits.................................................................................................................................3 What’s in the Box?.....................................................................................................................................3 Installation ...................................................................................................................................................4 Identifying the Electrical Wires in your Home............................................................................................4 Tools Needed ............................................................................................................................................4 Installing In-LineLinc Dimmer Dual-Band..................................................................................................5 Using In-LineLinc Dimmer Dual-Band ......................................................................................................6 LEDs..........................................................................................................................................................6 Using the ON and OFF Buttons ................................................................................................................6 Button Functions........................................................................................................................................6 Local On-Level ..........................................................................................................................................6 Beeper Behavior..........................................................................................................................................7 Setting Up an INSTEON Scene ..................................................................................................................7 Adding In-LineLinc Dimmer Dual-Band to a Scene as an INSTEON Responder.....................................7 Removing In-LineLinc Dimmer Dual-Band from a Scene as an INSTEON Responder............................7 Advanced Features.....................................................................................................................................8 Using In-LineLinc Dimmer Dual-Band as a Phase Bridge ........................................................................8 Power Restoration.....................................................................................................................................8 X10 Programming .......................................................................................................................................8 Factory Reset ............................................................................................................................................8 Local Ramp Rate.......................................................................................................................................9 Specifications............................................................................................................................................10 Troubleshooting........................................................................................................................................13 Certification and Warranty .......................................................................................................................14 Certification..............................................................................................................................................14 FCC and Industry Canada Compliance Statement.................................................................................14 Limited Warranty .....................................................................................................................................14 Limitations............................................................................................................................................14
                                                                  Page 3 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM  In-LineLinc Dimmer Dual-Band Congratulations on your purchase of the elegant, high-quality In-LineLinc Dimmer Dual-Band. In-LineLinc Dimmer Dual-Band installs in-line to provide INSTEON control of individual dimmable lighting fixtures. Additionally, In-LineLinc Dimmer Dual-Band eliminates the need for a conventional light switch, reducing the “switch sprawl” common to automation projects. You can also use In-LineLinc Dimmer Dual-Band for INSTEON signal repeating and phase bridging (like an Access Point, #2443). In-LineLinc Dimmer Dual-Band supports voltages from 100-277V, 50/60Hz and loads up to 400W, making it the perfect energy-saving, wireless controller.   Features and Benefits   Once installed, INSTEON setup is easy   Controls incandescent loads up to 400W   Supports up to 400 scene memberships   Shows INSTEON setup mode activity with beeper and dual-color Status LED    Communicates simultaneously over both radio frequency (RF) and the powerline   Acts as an Access Point for RF-only INSTEON devices   Stores setup state in non-volatile memory so settings aren’t lost during power outages   Wires into standard junction boxes (requires a NEUTRAL connection)  Two-year warranty   What’s in the Box?   In-LineLinc Dimmer Dual-Band   Quick Start Guide    Four (4) wire nuts
                                                                  Page 4 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM  Installation CAUTIONS AND WARNINGS Read and understand these instructions before installing and retain them for future reference. In-LineLinc Dimmer Dual-Band is intended for installation in accordance with the National Electric Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada. Use indoors only. In-LineLinc Dimmer Dual-Band is not designed nor approved for use on power lines other than single-phase voltages between 100v and 277v with 50 0r 60Hz service. Attempting to use In-LineLinc Dimmer Dual-Band on non-approved power lines may have hazardous consequences. Recommended installation practices: -  Use only indoors or in an outdoor-rated box  -  Be sure that you have turned off the circuit breaker or removed the fuse for the circuit in which you are installing In-LineLinc Dimmer Dual-Band. Installing In-LineLinc Dimmer Dual-Band with the power on will expose you to dangerous voltages. -  The wires connecting In-LineLinc to the incoming power must be protected by a fuse or circuit breaker of 15 amps or less -  Connect only copper or copper-clad wire to In-LineLinc Dimmer Dual-Band -  In-LineLinc Dimmer Dual-Band may feel warm during operation. The amount of heat generated is within approved limits and poses no hazards. To minimize heat buildup, ensure that the area surrounding the rear of In-LineLinc Dimmer Dual-Band is as clear of clutter as possible. -  Each In-LineLinc Dimmer Dual-Band is assigned a unique INSTEON I.D., which is printed on the device’s label.  -  To reduce the risk of overheating and possible damage to other equipment, use In-LineLinc Dimmer Dual-Band to control no more than 400 Watts of incandescent at 100VAC to 277VAC.  -  To reduce the risk of overheating and possible damage to other equipment, do not use this product to control Loads in excess of the specified maximum(s) or, install in locations with electricity specifications which are outside of the product’s specifications. If this device supports dimming, please note that dimming an inductive Load, such as a fan or transformer, could cause damage to the dimmer, the load bearing device, or both. If the manufacturer of the load device does not recommend dimming, use a non-dimming INSTEON on/off switch. USER ASSUMES ALL RISKS ASSOCIATED WITH DIMMING AN INDUCTIVE LOAD. -  You will need a flathead screwdriver, a Phillips screwdriver and a voltage meter to install In-LineLinc Dimmer Dual-Band  Identifying the Electrical Wires in your Home -  Line - usually black, may also be called Hot, Live or Power, carries 100-277VAC electricity into the wall box -  Neutral - usually white, commonly daisy-chained from box to box usually appearing as a white wire bundle -  Load - usually black from a separate cable jacket  -  Ground – Bare copper wire or metal fixture (if grounded) IMPORTANT! If you are not knowledgeable about and/or and comfortable with, electrical circuitry, you should have a qualified electrician install In-LineLinc Dimmer Dual-Band for you. If you have any questions, please consult an electrician or call the INSTEON Support Line at 800-762-7845. Tools Needed -  Flathead screwdriver      -   Phillips screwdriver -  Wire cutter/stripper       -   Voltage meter
                                                                  Page 5 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM  Wiring Diagram NOTE: Home’s wire colors and locations may vary Installing In-LineLinc Dimmer Dual-Band 1)  At electrical panel, turn off circuit breaker(s) and/or remove fuse(s) feeding wall box. Verify the power is off. 2)  Remove the fixture’s wallplate, unscrew the fixture and pull it out from the junction box. 3)  Disconnect the wires from the fixture and ensure that you have ½” of bare wire on the ends.1  4)  After ensuring wires are not touching, turn breaker(s) back on. 5)  Use a voltage meter to identify the Line and Load wires connected to the fixture, then identify Neutral and Ground wires. 6)  Turn off breaker(s). 7)  Connect wires according to the wiring diagram below. Confirm there are firm attachments with no exposed wire. 8)  Prior to reinstalling the fixture, turn on circuit breaker supplying power to the fixture. 9)  Use In-LineLinc Dimmer Dual-Band’s ON and OFF buttons to test load control. 10) Add In-LineLinc Dimmer Dual-Band to scene(s) as a responder to desired INSTEON devices. 11) Turn off breaker(s). 12) Gently place In-LineLinc Dimmer Dual-Band into the junction box, making sure nothing could accidentally press any of the buttons on its face. 13) Reinstall the fixture.  14) Turn on breaker(s).                                                         In-LineLinc Wire  Wall Box Wires Bare copper  Ground (commonly bare green wire or green screw) White  Neutral (commonly white wire bundle) Red  Load  (Light, etc.) Black  Line (100 - 277V to Neutral)
                                                                  Page 6 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM  Using In-LineLinc Dimmer Dual-Band  LEDs LED  Meaning Solid green  Load is on (at any dim level) Solid red  Load is off Blinking green  Unit is in linking mode Blinking red  Unit is in unlinking mode Fast blinking red and optional blink-on-traffic is turned on Dimmer is off and INSTEON traffic received Fast blinking green and optional blink-on-traffic is turned on Dimmer is on and INSTEON traffic received Using the ON and OFF Buttons The small button switches allows you to test the load and functions prior to final installation. -  Tap ON button to make load turn on at local ramp rate to local on-level brightness  -  Tap OFF button to make load turn off at local ramp rate to full-off  -  Double-tap ON button to make load turn full-on quickly  -  Double-tap OFF button to make load turn full-off quickly  -  Press and hold ON button to gradually brighten load to full-on  -  Press and hold OFF button to gradually dim load to full-off  Button Functions Button  Tap  Double-Tap  Press and Hold ON  Ramp to on-level  Fast on  Brighten OFF  Ramp to off  Fast off  Dim Set  Set the default on-level  Sets the default ramp rate  Starts linking mode  Local On-Level The local on-level is the brightness level at which the light(s) physically wired to In-LineLinc Dimmer Dual-Band turn on. The default on-level is 100%, but it can be adjusted to any brightness level.   1)  Use either ON or OFF buttons on In-LineLinc Dimmer Dual-Band to adjust light to desired brightness.  2)  Tap the  In-LineLinc Dimmer Dual-Band’s Set button. SwitchLinc will beep. 3)  Test on-level settings by tapping the ON/OFF buttons on In-LineLinc Dimmer Dual-Band.
                                                                  Page 7 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM  NOTE: If In-LineLinc Dimmer Dual-Band’s Status LED is blinking, you held the Set button down too long and accidentally placed it into linking mode, which times out after 4 minutes of inactivity. To manually exit linking mode, tap any button except Set button. Beeper Behavior The In-LineLinc Dimmer Dual-Band features a built-in beeper which aids in programming and can also be used as an indicator via compatible software controllers. Here are the different beeping behaviors and what they mean: -  Single beep: Transition from one setup mode to another - Double-beep: Successful link or unlink -  Continuous beeps for 3 seconds: unsuccessful link or 4-minute setup timeout -  Continuous beeps for 10 seconds: warning prior to a factory reset Setting Up an INSTEON Scene INSTEON remote control is done using scenes. Scenes allow you to instantly activate favorite lighting and appliance settings at the touch of a button (or in response to a command from a central controller or sensor). Each scene has at least one controller and at least one responder linked to one another. Simple scenes can be set up using the instructions below. Software such as HouseLinc is recommended for setup of larger scenes. Adding In-LineLinc Dimmer Dual-Band to a Scene as an INSTEON Responder 1)  Use the ON/OFF buttons on In-LineLinc Dimmer Dual-Band to adjust the load to the state you wish to activate from the controller .  2)  Press and hold the scene controller button until it beeps.1    Controller’s LED will blink. 3)  Press and hold the Set button on In-LineLinc Dimmer Dual-Band until it double-beeps. Controller will double-beep2 and its LED will stop blinking. 4)  Confirm that scene addition was successful by toggling the controller’s scene button on and off. Light should go to the level you defined in step 2. Removing In-LineLinc Dimmer Dual-Band from a Scene as an INSTEON Responder If you are going to uninstall In-LineLinc Dimmer Dual-Band, it is very important that you remove it from all of its scene controllers. Otherwise, controllers will experience delays and may produce flashing error indications.  1)  Press and hold controller’s scene button until controller beeps.3 Controller’s LED will blink. 2)  Press and hold Controller’s scene button until controller beeps again.3 Controller’s LED will continue blinking. 3)  Press and hold Set button on In-LineLinc Dimmer Dual-Band until it double-beeps. Controller will double-beep2 and its LED will stop blinking. 4)  Confirm scene removal was successful by tapping the button on the controller with the scene you just removed. In-LineLinc Dimmer Dual-Band will no longer respond.                                                        1 If the controller does not have a beeper, wait until its LED begins blinking 2 Most models 3 For devices without beepers hold until its LED begins blinking (this may take 10+ seconds)
                                                                  Page 8 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM  Advanced Features  Using In-LineLinc Dimmer Dual-Band as a Phase Bridge In-LineLinc Dimmer Dual-Band automatically bridges the electrical phases in your home to allow powerline-only INSTEON devices to communicate with RF-only INSTEON devices. If you are relying on In-LineLinc Dimmer Dual-Band to bridge the building’s electrical phases, use the following procedure to activate phase bridging detection mode:  1)  Start phase bridging detection mode by tapping In-LineLinc Dimmer Dual-Band’s Set button four times quickly. In-LineLinc Dimmer Dual-Band will begin beeping and setup LED will be solid green. 2)  Check the LED behavior of the “other” dual-band devices. a)  If it is blinking green, it is within range and not on the same electrical phase. Go to step 3. b)  If it is not blinking green, try moving the device, check other devices or begin the test from a different device. 3)  Tap In-LineLinc Dimmer Dual-Band’s Set Button. In-LineLinc Dimmer Dual-Band stops beeping and LED returns to previous state. Other devices’ LEDs will stop blinking in a few seconds. Power Restoration In-LineLinc Dimmer Dual-Band stores all of its scenes, properties, etc. in its internal non-volatile memory. As such, all settings are retained after a power outage. Upon power restoration, In-LineLinc Dimmer Dual-Band will return its connected load and all LEDs to their states prior to power outage. X10 Programming Instructions on setting X10 primary address and scene addresses can be found online at http://www.smarthome.com/insteon-x10-programming.html. Factory Reset Factory Reset clears all user settings from In-LineLinc Dimmer Dual-Band including INSTEON Scenes, On-Levels, Ramp Rates, X10 addresses, etc.   Option 1 1)  If possible, remove all scene memberships prior to performing the factory reset.  2)  Press and hold Set button on In-LineLinc Dimmer Dual-Band until it beeps.      LED will blink green. 3)  Press and hold In-LineLinc Dimmer Dual-Band’s Set button until it beeps again.   In-LineLinc Dimmer Dual-Band’s LED will blink red. 4)  Double-tap the Set button, then immediately press and hold it until the long beep stops.      In-LineLinc Dimmer Dual-Band will emit a long beep and its LED will turn off.     The connected load will turn on.  Option 2 – partner required 1)  If possible, remove all scene memberships prior to performing the factory reset.  2)  Turn off circuit breaker. 3)  While pressing and holding In-LineLinc Dimmer Dual-Band’s Set button (do not let go), have a partner turn on the circuit breaker.     As you continue to press and hold, In-LineLinc Dimmer Dual-Band will emit a long beep. 4)  Continue to press and hold Set button until long beep stops, then release.       As soon as you release Set button, In-LineLinc Dimmer Dual-Band LED will turn on.
                                                                  Page 9 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM  After a few seconds, In-LineLinc Dimmer Dual-Band will double-beep. The connected load will turn on.  Local Ramp Rate The local ramp rate is the time it takes for the light(s) physically wired to In-LineLinc Dimmer Dual-Band to brighten from off to 100% brightness and vice versa. The default ramp rate is 0.5 seconds, but it is adjustable from 0.1 seconds to 9 seconds locally or up to 8 minutes using software such as HouseLinc. Ramp rate is determined using the brightness level of the load. Refer to the chart below to determine the ramping speed based on the load brightness.  Brightness Level  Ramp Rate in Seconds 90-100% 0.1 77-87% 0.2 65-74% 0.3 52-61% 2.0 39-48% 2.0 26-35% 4.5 13-23% 6.5 1-10% 8.5 1% 9.0  1)  Adjust the connected light(s) to the brightness level corresponding to desired ramp rate. 2)  Double-tap In-LineLinc Dimmer Dual-Band’s Set button.     In-LineLinc Dimmer Dual-Band will double-beep. 3)  Test the ramp rate settings by tapping the ON/OFF buttons.     The connected light(s) will brighten and dim at the new rate. 4)  If your double-tap was not fast enough, you may have accidentally changed the local on-level instead of the local ramp rate. (Note: software such as HouseLinc allows you to remotely set on-levels and ramp rates exactly as desired and consistently around the house.)
                                                                  Page 10 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM   Specifications General Product name  In-LineLinc Dimmer Dual-Band – INSTEON Remote Control In-Line Dimmer (Dual-Band) Brand INSTEON Manufacturer product number  2475DA1 UPC 813922012361 FCC ID  SBP2475DA1 Patent number  7,345,998; protected under U.S. and foreign patents (see www.insteon.com ) Warranty  2 years, limited INSTEON INSTEON I.D.  1 INSTEON  400 responder groups and 1 controller group Maximum scene memberships  400 (combined controller and responder) On Off Fast on  Fast off Scene commands supported as responder Brighten Dim Software configurable  Yes, always RF range  100’ open air X10 support  Yes X10 addresses  1 max, unassigned by default
                                                                  Page 11 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM  INSTEON device category  0x01 INSTEON device subcategory  0x32 Mechanical Mounting  Mounts inside standard electrical box in the ceiling or in the wall Wires Colors:    White – Neutral 18-gauge   Black – Hot 16-gauge   Red – Load 16-gauge   Copper – Earth ground 16-gauge Set button  1 Beeper Yes LED  Dual-color green and red Dimensions  2.75" H x 1.75" W x 0.88" D Weight  120 grams / 0.26 pounds Operating environment  Indoors Operating temperature range  32 - 104 degrees Fahrenheit  (0 – 40 degrees Celsius) Operating humidity range  0-90% relative humidity, non-condensing Storage conditions  4F to +158F (-20 – 70 degrees Celsius) Electrical Voltage  100 to 277VAC (+/- 10%) Frequency  50/60Hz (+/- 5%) Auto Detected at power-up
                                                                  Page 12 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM  Maximum load  400 Watts  Load type(s)  Wired-in incandescent lighting  Retains all settings without power  Yes, all saved in Non-volatile EEPROM Standby power consumption  < 1 watt Safety approved  ETL (Intertek Testing Services) Certifications  FCC, IC Canada
                                                                  Page 13 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM   Troubleshooting Problem  Possible Cause  Solution Make sure the circuit breaker is turned on. In-LineLinc Dimmer Dual-Band won’t control the load and the Status LED is not turning on. In-LineLinc Dimmer Dual-Band may not be getting power. Check the junction box wires to ensure all connections are tight and no bare wires are exposed. The controller might have been reset without removing In-LineLinc Dimmer Dual-Band from a scene. Re-add In-LineLinc Dimmer Dual-Band to the controller. The INSTEON signal may be too weak. Add additional INSTEON devices or move around existing INSTEON devices. All INSTEON devices act as INSTEON network repeaters Large appliances such as refrigerators or air conditioners may be producing electrical noise on the powerline. In-LineLinc Dimmer Dual-Band won’t add to a scene or respond to a controller. Other electrical devices, such as computers, televisions, or power strips, may be absorbing the INSTEON signal. Install a powerline noise filter (FilterLinc #1626-10) to filter electrical noise and minimize signal attenuation. Remove any unused responders from the controller. HINT: If you are using home automation software such as HouseLinc, you can easily check scene membership and eliminate any unnecessary links.  In-LineLinc Dimmer Dual-Band is taking a long time to respond to a controller. The controller may be sending commands to a responder that is no longer in use. Commands for the unused responder are being resent and loading down the signal.  If the above doesn’t work, perform a factory reset on the controller. The load turned on by itself. Another controller or timer could have triggered In-LineLinc Dimmer Dual-Band. Perform a factory reset. See Factory Reset. The controller can turn off In-LineLinc Dimmer Dual-Band but it doesn’t turn on. In-LineLinc Dimmer Dual-Band may be added to a scene at its off state. Re-add In-LineLinc Dimmer Dual-Band to a scene on the controller while the load is on. See Adding In-LineLinc Dimmer Dual-Band to a Scene as an INSTEON Responder. In-LineLinc Dimmer Dual-Band is locked up. A surge or excessive noise on the powerline may have glitched it. Temporarily remove power from In-LineLinc Dimmer Dual-Band, usually by opening the breaker feeding it. If you have tried these solutions, reviewed this manual and still cannot resolve an issue you are having with In-LineLinc Dimmer Dual-Band, please call the INSTEON Support Line at 800-762-7845.
                                                                  Page 14 of 14                                    2475DA1 - Rev: 4/20/2012 4:35 PM   Certification and Warranty Certification This product has been thoroughly tested by Intertek ETL, a nationally recognized independent third-party testing laboratory. The North American ETL Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U.S. and Canadian device safety standards, that the manufacturing site has been audited, and that the manufacturer has agreed to a program of quarterly factory follow-up inspections to verify continued conformance.  FCC and Industry Canada Compliance Statement This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS-210. Operation is subject to the following two conditions:  (1) This device may not cause harmful interference, and  (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes:  (1) l'appareil ne doit pas produire de brouillage, et  (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15.107 and 15.109 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: -  Re-orient or relocate the receiving antenna of the device experiencing the interference -  Increase the distance between this device and the receiver -  Connect the device to an AC outlet on a circuit different from the one that supplies power to the receiver -  Consult the dealer or an experienced radio/TV technician WARNING: Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  Limited Warranty Seller warrants to the original consumer purchaser of this product that, for a period of two years from the date of purchase, this product will be free from defects in material and workmanship and will perform in substantial conformity to the description of the product in this Owner’s Manual. This warranty shall not apply to defects or errors caused by misuse or neglect. If the product is found to be defective in material or workmanship, or if the product does not perform as warranted above during the warranty period, Seller will either repair it, replace it, or refund the purchase price, at its option, upon receipt of the product at the address below, postage prepaid, with proof of the date of purchase and an explanation of the defect or error. The repair, replacement, or refund that is provided for above shall be the full extent of Seller’s liability with respect to this product. For repair or replacement during the warranty period, call the INSTEON Gold Support Line at 800-762-7845 with the Model # and Revision # of the device to receive an RMA# and send the product, along with all other required materials to:   INSTEON ATTN: Receiving 16542 Millikan Ave. Irvine, CA 92606-5027 Limitations The above warranty is in lieu of and Seller disclaims all other warranties, whether oral or written, express or implied, including any warranty or merchantability or fitness for a particular purpose. Any implied warranty, including any warranty of merchantability or fitness for a particular purpose, which may not be disclaimed or supplanted as provided above shall be limited to the two-year of the express warranty above. No other representation or claim of any nature by any person shall be binding upon Seller or modify the terms of the above warranty and disclaimer.  Home automation devices have the risk of failure to operate, incorrect operation, or electrical or mechanical tampering. For optimal use, manually verify the device state. Any home automation device should be viewed as a convenience, but not as a sole method for controlling your home.  In no event shall Seller be liable for special, incidental, consequential, or other damages resulting from possession or use of this device, including without limitation damage to property and, to the extent permitted by law, personal injury, even if Seller knew or should have known of the possibility of such damages. Some states do not allow limitations on how long an implied warranty lasts and/or the exclusion or limitation of damages, in which case the above limitations and/or exclusions may not apply to you. You may also have other legal rights that may vary from state to state.  Protected under U.S. and foreign patents (see www.insteon.com ) © Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845, www.insteon.com

Navigation menu