Sony 6220512 Mobile Base Unit User Manual GT47 Integrators Manual
Sony Mobile Communications Inc Mobile Base Unit GT47 Integrators Manual
Sony >
Contents
- 1. Technical Manual
- 2. Integrators Manual
Integrators Manual
GT47/GT48 Integrators Manual P ro duc tP ho to /Illustratio n The product described in this manual conforms to the Radio and Telecommunication Terminal Equipment (R&TTE) directive 99/5/EC with requirements covering EMC directive 89/336/EEC and Low Voltage directive 73/23/EEC. The product fulfils the requirements according to 3GPP TS 51.010-1, EN 301 489-7 and EN60950. SAR statement: This product is intended to be used with the antenna or other radiating element at least 20cm away from any part of the human body. The information contained in this document is the proprietary information of Sony Ericsson Mobile Communications International. The contents are confidential and any disclosure to persons other than the officers, employees, agents or subcontractors of the owner or licensee of this document, without the prior written consent of Sony Ericsson Mobile Communications International, is strictly prohibited. Further, no portion of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, without the prior written consent of Sony Ericsson Mobile Communications International, the copyright holder. First edition (August 2003) Sony Ericsson Mobile Communications International publishes this manual without making any warranty as to the content contained herein. Further Sony Ericsson Mobile Communications International reserves the right to make modifications, additions and deletions to this manual due to typographical errors, inaccurate information, or improvements to programs and/or equipment at any time and without notice. Such changes will, nevertheless be incorporated into new editions of this manual. All rights reserved. © Sony Ericsson Mobile Communications International, 2003 Publication number: LZT 123 7605 P1C Printed in UK Contents Overview ................................................................................................................... 5 1. Introduction .............................................................................................................. 6 Target Users ................................................................................................................ 6 Prerequisites................................................................................................................ 6 Manual Structure......................................................................................................... 6 2. GT47/GT48 Control Terminals................................................................................ 7 Description.................................................................................................................. 7 Highlights .................................................................................................................. 7 Control Terminals in a Communication System........................................................... 8 Main Features and Services ....................................................................................... 10 Service and Support ................................................................................................... 15 Precautions................................................................................................................ 15 3. Abbreviations and Definitions............................................................................... 16 Integrating the Control Terminal ........................................................................... 18 4. Mechanical Description .......................................................................................... 19 Overview ................................................................................................................... 19 Physical Dimensions.................................................................................................. 21 5. Electrical Description ............................................................................................. 22 Power Supply and Extended I/O Connector ............................................................... 22 RS232 Serial and Extended I/O Interface ................................................................... 25 Audio Connector ....................................................................................................... 31 Antenna Connector.................................................................................................... 33 SIM Card Reader ....................................................................................................... 34 Real Time Clock........................................................................................................ 35 Software Updates....................................................................................................... 35 6. Embedded Applications ......................................................................................... 36 Features ..................................................................................................................... 36 Implementation......................................................................................................... 36 7. TCP/IP Stack........................................................................................................... 38 Implementation......................................................................................................... 38 8. Operation................................................................................................................. 39 Switching On the Control Terminal .......................................................................... 39 Switching Off the Control Terminal .......................................................................... 39 LZ T123 7 605 P1C Resetting the Control Terminal................................................................................. 39 Operating States/LED................................................................................................ 39 Power Save ................................................................................................................ 40 Controller Mode ........................................................................................................ 40 9. Safety and Product Care ......................................................................................... 41 Safety Instructions ..................................................................................................... 41 General Precautions................................................................................................... 41 SIM Card Precautions ................................................................................................ 42 Antenna Precautions.................................................................................................. 42 10. Installation of the Control Terminal...................................................................... 44 Where to Install the Control Terminal ...................................................................... 44 How to Install the Control Terminal ......................................................................... 45 Antenna .................................................................................................................... 46 Accessories ................................................................................................................ 47 11. Technical Data ........................................................................................................ 49 LZ T123 7 605 P1C Overview P ro duc tP ho to /Illustratio n 1. Introduction 1.1 Target Users GT47 and GT48 Control Terminals are designed to be integrated into machine-machine or man-to-machine communications applications. They are intended to be used by manufacturers, system integrators, applications developers and developers of wireless communications equipment. 1.2 Prerequisites It is assumed that the person integrating the GT47/GT48 into an application has a basic understanding of the following: • GSM networking; • Wireless communication and antennas (aerials); • AT commands; • ITU-T standard V.24/V.28; • Micro controllers and programming; • Electronic hardware design. 1.3 Manual Structure The manual is composed of two parts Part 1- Overview This section provides a broad overview of the GT47/GT48 and includes a list of abbreviations used in the manual. Part 2 - Integrating the Control Terminal This section describes each of the signals available on the GT47/GT48 Control Terminal, along with mechanical information. The section also provides you with design guidelines and explains what is needed to commercialise an application from a regulatory point of view. LZ T123 7 605 P1C 2. GT47/GT48 CONTROL TERMINALS 2. GT47/GT48 Control Terminals 2.1 Description Two Control Terminals make up the family; GT47 and GT48, for use in the E-GSM900/GSM1800 and GSM850/GSM1900 bands respectively. The Control Terminal has a radio device embedded in it. The GT47 incorporates the GR47 radio device; the GT48 incorporates the GR48 radio device. Note! This manual refers to the GT47 and GT48 as Control Terminals. If there is a difference in the functionality of the Control Terminals the GT47 and GT48 information will be listed separately. The Control Terminal is a powerful and flexible device that can be used in a wide range of telemetry and telematics applications that rely on the remote exchange of data, voice, SMS or faxes via the GSM cellular network. Small and lightweight, the Control Terminal has standard connectors and an integral SIM card reader making it easy and quick to integrate. As well as providing a standard RS232 serial communication interface the Control Terminal also has an audio interface allowing an analogue handset to be connected. When the Control Terminal is integrated into an external application, a wireless communications system is created. A typical end-to-end system consists of a micro controller in an external application communicating, via the Control Terminal, with a remote terminal or host using the GSM network. The micro controller uses a set of AT commands to control the Control Terminal, and to set up the end-toend communications link, via its 9-way RS232 serial interface. These Control Terminals are intended to be used by manufacturers, system integrators, application developers and developers of a wide range of equipment and business solutions, typically in the following fields: • Security and alarms • Vending • Monitoring and control • Utilities • Fleet Management 2.2 Highlights • Intelligent, versatile GSM/GPRS Control Terminal • Dual band, EGSM 900/GSM1800 (GT47); GSM 850/GSM1900 (GT48) • Customised applications can be embedded and run independently • Self contained terminal with standard connectors LZ T123 7 605 P1C 2. GT47/GT48 CONTROL TERMINALS • • • • • • • • • • • 2 x RS232 interfaces with a useful range of configurable IOs TCP/IP stack Data: GPRS, HSCSD, CSD, SMS Voice: full rate, enhanced full rate, half rate; AMR (GT48) SMS: mobile-originated, mobile-terminated, cell broadcast Fax: Group 3, Classes 1 & 2 15 way high density connector 5V to 32V d.c. input 4-wire audio connection Antenna connection (FME male) R&TTE type approved (GT47) 2.3 Control Terminals in a Communication System Figures 2.1 and 2.2 illustrate the main blocks of a wireless communication system using the Control Terminal. Figure 2.1 shows the communication system when the script is embedded on the Control Terminal and figure 2.2 shows the communication system when a micro-controller is used. They also show the communication principles of the system and the interface between the Control Terminal and the application. The definitions in the figures, as used elsewhere in this manual, are in accordance with the recommendations of GSM 07.07. • The MS (mobile station) represents the Control Terminal and SIM card. The Control Terminal excluding SIM card, is known as the ME (mobile equipment). • The DTE (data terminal equipment) is the controlling application. This can be either an external host or an internal embedded application. • The DCE (data circuit terminating equipment) is the serial communication interface of the MS. LZ T123 7 605 P1C 2. GT47/GT48 CONTROL TERMINALS GSM NETWORK MS GT47 / GT48 SIM SYSTEM CONNECTOR POWER SUPPLY GSM ENGINE EMBEDDED APPLICATION STATUS & RESPONSE DCE DTE ‘AT’ COMMAND CONTROL Figure 2.1 Main Blocks in a Wireless System (embedded application) GSM NETWORK MS GT47 / GT48 SIM EXTERNAL APPLICATION MS STATUS & RESPONSE SYSTEM CONNECTOR POWER SUPPLY GSM ENGINE DCE DTE DTE ‘AT’ COMMAND CONTROL Figure 2.2 Main Blocks in a Wireless System (external micro-controller) LZ T123 7 605 P1C 2. GT47/GT48 CONTROL TERMINALS In accordance with the recommendations of ITU-T (International Telecommunication Union - Telecommunications Standardisation Sector) V.24, the TE communicates with the MS over a serial interface. The functions of the radio device follow the recommendations provided by ETSI (European Telecommunications Standards Institute) and ITU-T. ETSI specifies a set of AT commands for controlling the GSM element of the Control Terminal; these commands are supplemented by Sony Ericsson specific commands. Note! To find out how to work with AT commands, see the GR47/GR48 AT Commands Manual. 2.4 Main Features and Services The Control Terminal performs a set of telecom services (TS) according to GSM standard phase 2+, ETSI and ITU-T. The services and functions of the Control Terminal may be implemented using customised applications embedded on the device, or by AT commands over the RS232 serial interface. 2.4.1 Types of Mobile Station The GT47 and GT48 are dual band Control Terminals with the GSM radio characteristics shown in the table below. GT47 E-GSM900 GSM1800 Frequency Range (MHz) TX: 880-915 RX: 925-960 TX: 1710-1785 RX: 1805-1880 Channel spacing 200kHz 200kHz Number of channels 174 carriers *8 time slots 374 carriers *8 time slots Modulation GMSK GMSK TX phase accuracy < 5º RMS phase error (burst) < 5º RMS phase error (burst) Duplex spacing 45MHz 95MHz Receiver sensitivity at antenna connector < –102dBm < –102dBm Transmitter output power at antenna connector Class 4 2W (33dBm) Class 1 1W (30dBm) Automatic hand-over between EGSM 900 and GSM1800 10 LZ T123 7 605 P1C 2. GT47/GT48 CONTROL TERMINALS GT48 GSM850 GSM1900 Frequency Range (MHz) TX: 824-849 RX: 869-894 TX: 1850-1910 RX: 1930-1990 Channel spacing 200kHz 200kHz Number of channels 124 carriers *8 time slots 299 carriers *8 time slots Modulation GMSK GMSK TX Phase Accuracy < 5º RMS phase error (burst) < 5º RMS phase error (burst) Duplex spacing 45MHz 80MHz Receiver sensitivity at antenna connector < –102dBm < –102dBm Transmitter output power at antenna connector Class 4 2W (33dBm) Class 1 1W (30dBm) Automatic hand-over between GSM850 and GSM1900 2.4.2 Short Message Service The Control Terminal supports the following SMS services: • Sending; MO (mobile-originated) with both PDU (protocol data unit) and text mode supported. • Receiving; MT (mobile-terminated) with both PDU and text mode supported. • CBM (cell broadcast message); a service in which a message is sent to all subscribers located in one or more specific cells in the GSM network (for example, traffic reports). This feature is network dependent. • SMS STATUS REPORT according to GSM 03.40. • SMS COMMAND according to GSM 03.40. The maximum length of an SMS message is 160 characters when using 7bit encoding. For 8-bit data, the maximum length is 140 characters. The Control Terminal supports up to 6 concatenated messages to extend this function. 2.4.3 Voice Services The Control Terminal offers the capability of mobile originated and mobile terminated voice calls, as well as supporting emergency calls. Multi-party, call waiting and call divert features are available. Some of these features are network-operator specific. For the inter-connection of audio, the Control Terminal offers a balanced 4-wire analogue interface. DTMF (Dual Tone Multi Frequency) is supported. 11 LZ T123 7 605 P1C 2. GT47/GT48 CONTROL TERMINALS The Control Terminal supports HR, FR and EFR vocoders. The GT48 also supports the Adaptive Multi Rate (AMR) type of vocoder. 2.4.4 Data The Control Terminal supports the following data protocols: • GPRS (General Packet Radio Service). The Control Terminal is Class B, which provide simultaneous activation and attachment of GPRS and GSM services. GT47 is a GPRS class 8 (4+1) enabled devices, which are capable of transmitting in one timeslot per frame (up link), and receiving at a maximum of four timeslots per frame (down link). • CSD (Circuit Switched Data). The Control Terminal GT47 is a capable of establishing a CSD communication at 9.6kbps. • HSCSD (High Speed Circuit Switched Data). The Control Terminal supports HSCSD class 2 (2+1) communication, with one timeslot per frame capacity in the up link and two timeslots per frame capacity in the down link. 2.4.5 Fax The Control Terminal allows fax transmissions to be sent and received by commercial fax software installed on the application computer. Group 3 fax Classes 1 and 2 are supported. 2.4.6 Supplementary Services • • • • • • • • • • • • Call forwarding Call hold, waiting and multiparty Calling/called number identification Advice of charge USSD Alternate line service Customer service profile Preferred networks Operator selection Network registration Call barring Call transfer 12 LZ T123 7 605 P1C 2. GT47/GT48 CONTROL TERMINALS 2.4.7 Serial Communication The Control Terminal enables an end-to-end communication path to be established between the telemetry/telematics application, either hosted internal or connected externally, and a remote terminal or host, via the GSM network. Once a path has been set up, voice or data communication can take place. An RS232 9-signal serial interface is available via the Control Terminal’s 15-way high density data connector. This primary serial interface can be used to: 1.C o ntro lthe G T47 via an external PC o r m ic ro -c o ntro ller using AT c o m m ands; 2.Send and rec eive data. The Control Terminal supports the full set of AT commands according to GSM 07.05 and GSM 07.07. It also supports an extended set of Ericsson proprietary AT commands to add extra functionality. AT commands are used to operate the Control Terminal with a broad range of functions including: • configuring general parameters of the Control Terminal • setting up and controlling communications to and from the GSM network • obtaining GSM network status information Additionally the Control Terminal provides a second RS232 serial interface, operating as a 4-signal and GND interface, with hardware flow control (Rx, Tx, CTS and RTS). This 4-signal serial interface is controllable via embedded applications and may be used to control external accessories e.g. a GPS receiver. For more detail on the AT commands supported by the Control Terminal see GR47/GR48 AT Commands Manual. 2.4.8 Extended I/O Interface The Control Terminal contains several general purpose, configurable, input and output signals. Signals may be reconfigured by AT command or by intrinsic function when using embedded applications. • 1 analogue input • 3 digital inputs • 5 digital outputs • + 4.8V DC output In addition, 6 of the control signals on the primary RS232 interface can be reconfigured for use as digital inputs or outputs if required. 13 LZ T123 7 605 P1C 2. GT47/GT48 CONTROL TERMINALS The drivers controlling certain outputs have been designed to carry higher currents than normal logic IOs. They can be used to activate or power external devices, for example a switch or a relay. A+4.8V output is available, if required, to power external devices. 2.4.9 Interfacing with the Control Terminal The Control Terminal uses the following industry standard connectors; • 15 pin high density socket (RS232 serial port and extended I/O interface) • RJ12 (plug-in power supply and extended I/O connector) • RJ9 (handset audio connector) • Integral SIM card reader • FME male (antenna connector) 14 LZ T123 7 605 P1C 2. GT47/GT48 CONTROL TERMINALS 2.5 Service and Support To contact customer support please use the details below: Customer Support Sony Ericsson Mobile Communications 1 Lakeside Road Aerospace Centre Farnborough Hampshire GU14 6XP E-mail: modules.support@sonyericsson.com or modules.info@sonyericsson.com Information about Sony Ericsson and its products is available on the following web site: http://www.SonyEricsson.com/M2M 2.6 Precautions As a standalone item, the Control Terminal is designed for indoor use only. To use outdoors it must be integrated into a weatherproof enclosure. Do not exceed the environmental and electrical limits as specified in “Technical Data”, page 49. 15 LZ T123 7 605 P1C 3. ABBREVIATIONS AND DEFINITIONS 3. Abbreviations and Definitions Abbreviation Explanations AMR Adaptive Multi Rate CBM Cell Broadcast Message CBS Cell Broadcast Service CSD Circuit Switched Data DCE Data Circuit Terminating Equipment DTE Data Terminal Equipment DTMF Dual Tone Multi Frequency EFR Enhanced Full Rate EMC Electro-Magnetic Compatibility ETSI European Telecommunication Standards Institute FR Full Rate GPRS General Packet Radio Service GSM Global System for Mobile Communication High Side Switch Pin is driven high, to Vin, in the active state HR Half Rate HSCSD High Speed Circuit Switched Data ITU-T International Telecommunication Union - Telecommunications Standardisation Sector Low Side Switch Pin is driven low in the active state. High state requires external pull up. ME Mobile Equipment MO Mobile Originated MS Mobile Station MT Mobile Terminated PDU Protocol Data Unit RLP Radio Link Protocol RF Radio Frequency RTC Real Time Clock SIM Subscriber Identity Module SMS Short Message Service 16 LZ T123 7 605 P1C 3. ABBREVIATIONS AND DEFINITIONS Abbreviation Explanations TA Terminal Adapter TE Terminal Equipment TS Telecommunication Services USSD Unstructured Supplementary Service Data 17 LZ T123 7 605 P1C Integrating the Control Terminal P ro duc tP ho to /Illustratio n 4. Mechanical Description 4.1 Overview The pictures below show the mechanical design of the Control Terminal along with the positions of the different connectors and mounting holes. The Control Terminal case is made of durable PC/ABS plastic. LED Antenna connector Access to SIM card RS232 serial and extended I/O connector Figure 4.1 Control Terminal viewed from the left side Mounting hole (x2) Audio connector Power supply and extended I/O connector Figure 4.2 Control Terminal viewed from the right side 19 LZ T123 7 605 P1C 4. MECHANICAL DESCRIPTION Please note the following: • Mounting holes positioned at two of the corners make it possible to securely bolt the Control Terminal into your application. • Keypad, display, microphone, speaker and battery are not part of the Control Terminal. • The SIM card is mounted in the Control Terminal. • The pins and electrical characteristics of the Control Terminal’s various connectors are described in “Electrical Description”, page 22. • Information about the antenna connector is found in “Antenna Connector”, page 33. 20 LZ T123 7 605 P1C 4. MECHANICAL DESCRIPTION 4.2 Physical Dimensions 3.5 71 (x 45.3 51.0 66.4 .5 2) 9.0 26.2 55.3 10.6 11.0 11.0 7 7 .4 Measurements are given in millimetres. See also “Technical Data”, page 49. 21 LZ T123 7 605 P1C 5. ELECTRICAL DESCRIPTION 5. Electrical Description All electrical connections to the module are protected in compliance with the standard air (8kV) and contact (4kV) Electrostatic Discharge (ESD) tests, of EN 61000-4-2. The module uses the following industry standard connectors: • High density 15 pin (RS232 serial and extended I/O interface) • RJ12 6-way (power supply and extended I/O connector) • RJ9 4-way (handset connector) • SIM card reader • FME male coaxial jack (antenna connector) 5.1 Power Supply and Extended I/O Connector An RJ12 6-way connector, as shown and described below, serves as a means of supplying and controlling d.c. power to the modem. Additionally there are several extended input/output signals available that can be used to control or interface external systems and devices. General signal description: VIN OUT-2 IN-1 TO_IN OUT-1 GND 22 LZ T123 7 605 P1C 5. ELECTRICAL DESCRIPTION The power connector electrical characteristics are listed below: Note! Pin Signal Dir Limits Description VIN 5 to 32V Positive power input OUT-2 32V, 0.25A Low side switch, short circuit protected IN-1 –0.5 to 32V Digital Input VIH > 3V, VIL < 2.8V Internal Pull Down of 40kΩ TO_IN –0.5 to 32V Active low control line used to switch the GT47 off/on. VIH > 5V, VIL < 2V Power off/on: t > 0.2s Internal Pull Up to VIN of 20kΩ OUT-1 VIN, 0.4A High side switch, short circuit protected GND Negative power (ground) input and return path for TO_IN and the extended inputs and outputs Signal OUT-2 on the RJ12 connector is switched in parallel to signal OUT-4 on the 15-pin high density socket. The individual output signals are generated by two different low side switches inside the module driven from a common control signal. 5.1.1 Power Supply Interface The supply voltage VIN and GND are protected against polarity reversal and over voltage. The Control Terminal switches on automatically once the VIN voltage is applied. Note! The Control Terminal will not switch on if TO_IN is shorted to ground when the dc supply is applied. Note! For more information on switching the Control Terminal on and off please see section “Operation”, page 39 Note! Please be aware that the total current carried via either the VIN or GND pins will be the sum of the intrinsic power consumption of the Control Terminal and any drive current supplied via OUT-1 or OUT-2 (or other IOs). The current on either of the VIN or GND pins must not exceed 1.5A. Caution! It is recommended that the system integrator provides appropriate fusing otherwise the Control Terminal may be damaged. See “Current Consumption with external +4.8V Supply Active”, page 53 for more details. 23 LZ T123 7 605 P1C 5. ELECTRICAL DESCRIPTION Extended I/O Signals Digital Inputs The digital input IN-1 is available on pin 3 of the RJ12 connector. Its state is detected by IO5 of the embedded Radio Device engine, see Control Terminal-Radio Device signal cross reference table, page 30. The distinction between low level and high level signals is at the voltage level of 3 V. Voltages above 3 V are detected as high level voltages and voltages below 2.8 V are detected as low level. Digital Outputs The RJ12 power supply connector has two different output drivers: • OUT-1 is driven by a high side switch that applies VIN to pin 5 of the RJ12 connector. IO1 of the embedded radio device is used to activate the OUT-1 signal, see Control Terminal - radio device signal cross reference table, page 30. • OUT-2 is driven by a low side switch that shorts pin 2 of the RJ12 connector to ground when activated. IO3 of the embedded Radio Device engine is used to activate OUT-2, see Control Terminal - Radio Device signal cross reference table, page 30. IMAGE -TBD VIN Monitoring The voltage, VIN, can be monitored internally by the Control Terminal, for example if the Control Terminal is supplied from an external battery. ADC1 on the Radio Device is used for this purpose, see Control TerminalRadio Device signal cross reference table, and is calibrated to operate in the voltage range 0 – 31.875 V. The resolution of the 8 bit converter, ADC1, provides a measurement accuracy of approximately 3%. 24 LZ T123 7 605 P1C 5. ELECTRICAL DESCRIPTION 5.2 RS232 Serial and Extended I/O Interface The Control Terminal supports a standard 9 signal RS232 serial interface (EIA/TIA 574) on the 15 pin high density connector together with a range of configurable I/Os including a second 4-wire logic level RS232 interface. 11 12 13 14 15 6 7 8 9 10 1 2 3 4 5 11 IN-2 12 OUT-4 13 DTR 14 GND 15 ANA_IN 6 DSR 7 RTS 8 C TS 9 4.8V 10 RI 1 DC D 2 RD 3 TD 4 IN-3 5 OUT-3 Signals that support an alternative configuration can be reconfigured using the appropriate AT command (e.g. AT+E2IO) or via an intrinsic function if using an embedded application. Note! When reconfiguring a Control Terminal signal, via AT command or intrinsic function, the corresponding Radio Device signal name must be used, see Control Terminal-Radio Device signal cross reference table, page 30. The electrical characteristics of the serial port signals are shown below: Pin Control Terminal Signal Dir Max. Voltage limits Description DCD ±13.2V RS232 signal Data carrier detect Vout ≥ ±5V RD ±13.2V RS232 signal: Received data Vout ≥ ±5V TD ± 25V RS232 signal: Transmitted data VIL < 0.6V, VIH > 2.4V IN-3 -0.5 to 32V Digital input VIH > 3V, VIL < 2.8V PullDown with 40kΩ OUT-3 32V, 0.25A low side switch, short circuit protected DSR ±13.2V RS232 signal: Data set ready Vout ≥ ±5V RTS ±25V RS232 signal: Request to send VIL < 0.6V, VIH > 2.4V 25 LZ T123 7 605 P1C 5. ELECTRICAL DESCRIPTION Pin Control Terminal Signal Dir Max. Voltage limits Description CTS ±13.2V RS232 signal: Clear to send Vout ≥ ±5V 4.8V 0 to +4.8V, Voltage supply for external devices 75mA Supply voltage +4.8V, max. current 75mA 10 RI ±13.2V 11 IN-2 -0.5 to 32V Digital input VIH > 3V, VIL < 2.8V PullDown with 40kΩ 12 OUT-4 32V, 0.25A low side switch, short circuit protected 13 DTR ±25V RS232 signal: Data Terminal Ready VIL < 0.6V, VIH > 2.4V 14 GND Ground connection and return path for the extended inputs/outputs 15 ANA_IN -0.5 to 32V Analog input measurement range: 0 to 12.75V RS232 signal: Ring indicator Vout ≥ ±5V 5.2.1 Standard RS232 Serial interface and Signals The module supports a standard RS232 serial interface (EIA/TIA 574) via its 15 pin high density connector, shown above. 5.2.2 Serial Data The Control Terminal supports the standard data character format of 1 start bit, 8 bit data, no parity plus 1 stop bit, in total 10 bits per character. In line with serial communication terminology the module is the data circuit-terminating equipment (DCE) and the external application or computer is the data terminating equipment (DTE). 5.2.3 Serial Data Signals - RD, TD The default baud rate is 9.6kbps, however higher bit rates up to 230.4kbps are supported and can be set by AT commands. At start-up the module transmits and receives data at the default rate of 9.6kbps in either standard AT mode or binary mode (the first received data - AT or binary format determines the operating mode). Serial Data From GT47 (RD) Pin 2 RD is an output signal that the Control Terminal uses to send data to the external application. 26 LZ T123 7 605 P1C 5. ELECTRICAL DESCRIPTION Serial Data To Control Terminal (TD) Pin 3 TD is an input signal, used by the external application to send data to the Control Terminal. 5.2.4 Control Signals - RTS, CTS, DTR, DSR, DCD, RI Request to Send (RTS) Pin 7 Used to condition the Control Terminal for data transmission. The default level is inactive by internal pull down. The exact behaviour of RTS is defined by an AT command. Software or hardware flow control can be selected. Hardware flow control is the default selection. The application must pull RTS high to enable transmission from the Control Terminal. Clear To Send (CTS) Pin 8 CTS indicates that the Control Terminal is ready to transmit data. The default level is high. You can define the exact behaviour of CTS through an AT command, and can select software or hardware flow control. Data Terminal Ready (DTR) Pin 13 DTR indicates that the DTE is ready to send and receive data. It also acts as a hardware ‘hang-up’, terminating calls when switched low. The signal is active high. You can define the exact behaviour of DTR with an AT command. Data Set Ready (DSR) Pin 6 An active DSR signal is sent from the Control Terminal to the application (DTE) to confirm that a communications path has been established. DSR has two modes of operation, use the AT command AT&S to set the mode. Data Carrier Detect (DCD) Pin 1 DCD indicates that the Control Terminal is receiving a valid carrier (data signal) when high. You can define the exact behaviour of DCD with an AT command. Ring Indicator (RI) Pin 10 RI indicates that a ringing signal is being received by the Control Terminal when high. You can define the exact behaviour of RI with an AT command. 27 LZ T123 7 605 P1C 5. ELECTRICAL DESCRIPTION Alternative Configuration It is possible to reconfigure one or more of the signals in this section (RTS, CTS, DTR, DSR DCD and RI) to be used as digital inputs or outputs if the full RS232 serial interface is not required. Configuration is achieved using AT command (AT+E2IO) or via embedded application intrinsic functions, please refer to Control Terminal-Radio Device signal cross reference table, page 30. To be reconfigured as a digital IO, each signal must retain the direction and the logic voltage levels attributed to it when used as an RS232 signal. For example DSR can only be reconfigured as a digital output with Vout ≥ ±5V. 5.2.5 Extended I/O Signals Please refer to Control Terminal-Radio Device signal cross reference table, page 30, for more information on the relationship between signal names and pin numbers of the Control Terminal and the embedded Radio Device engine. Digital Inputs Pin 4 & 11 Digital inputs IN-2 and IN-3 are available on the HD15 connector via pins 11 and 4 respectively. The inputs are detected via signals IO4 and IO7 of the embedded Radio Device engine. Note! As an alternative configuration signals IN-2 and IN-3 can be used to support a second RS232 serial interface as RTS-2 and TD-2. Further information is given below. Analog Input Pin 15 The signal ANA_IN can be used for measuring analog input values in the range 0 to 12.75V. ADC2 of the embedded GR47 is used to detect ANA_IN. The resolution of the converter is 8 bit with an measurement accuracy of about 3%. The input impedance of the ANA_IN pin is 50 kΩ. Digital Outputs Pin 5 & 12 Digital outputs OUT-3 and OUT-4 are available on the HD15 connector via pins 5 and 12 respectively. The outputs are controlled via signals IO8 and IO3 of the embedded Radio Device engine. Signal OUT-4 on the HD15 connector is switched in parallel to signal OUT-2 on the RJ12 connector. The individual output signals are generated by two different low side switches inside the terminal driven from the common control signal, IO3. All Control Terminal output signals 28 LZ T123 7 605 P1C 5. ELECTRICAL DESCRIPTION driven by low side switches return to open circuit when deactivated. This allows the external application hardware to determine the desired logic voltage levels with the appropriate pull-up. The output drivers are low side switches which short the pin to GND if they are activated. Note! As an alternative configuration signals OUT-3 and OUT-4 can be used to support a second RS232 serial interface as RD-2 and CTS-2. Further information is given below. +4.8V Output Supply Pin 9 There is a voltage regulator implemented inside the module that is capable of supplying an external voltage source of +4.8V with a maximum current of 75 mA. The voltage source can be switched on/off with the DAC signal of the internal Radio Device GSM engine. By default the voltage source is switched on. A high level of 2.75V at the DAC output of the Radio Device GSM engine will switch the voltage source off. Note! The +4.8V source may be switched on/off via an embedded or external application and so may be used as an optional digital output with levels of +4.8V and open circuit. 5.2.6 Second RS232 Serial Interface IN-3 and OUT-3 can be automatically reconfigured as signals TD-2 and RD-2, of a second serial interface, by enabling UART3 of the internal Radio Device. UART 3 may be enabled using AT command or intrinsic function. In addition, IN-2 and OUT-4 can be automatically reconfigured as signals RTS-2 and CTS-2 of the second serial interface by enabling hardware flow control for UART3 on the internal Radio Device. Hardware flow control can be enabled using intrinsic function only. Note! The signal level thresholds for each of the digital inputs of the second serial interface are: 3V0.2s, then release. • activate the main RS232 control line DTR, low to high for >0.2s The Control Terminal is fully operational after 4 seconds. Logging onto a network may take longer than this and is outside the control of the Control Terminal. Note! The Control Terminal will not switch on if TO_IN is shorted to ground when the dc supply is applied. 8.2 Switching Off the Control Terminal There are two ways to switch off the Control Terminal as described below. • Use the appropriate AT command (AT+CFUN); • pull signal TO_IN to ground for t >0.2s, then release. 8.3 Resetting the Control Terminal A full system reset, independent of the status of the software, may be applied to the Control Terminal as follows: • assert HR_IN high for > 3.5s. 8.4 Operating States/LED The Control Terminal has a green LED, as depicted below, which is used to indicate various operating states. These states are described in following table. LED 39 LZ T123 7 605 P1C 8. OPERATION Operating state LED After switching on the Control Terminal On after 4s Control Terminal switched off or power removed from the module Off Standby or talk Flashing No network, network search, no SIM card, no PIN entered On 8.5 Power Save The Control Terminal can power down the main RS232 IC when not needed in order to minimise power consumption. The IC is powered up automatically at start-up but can be powered down by setting the output of IO2 on the embedded Radio Device (pin22) to low via AT command or embedded application. Once powered down, the IC can be woken up by setting the output of IO2 high on the Radio Device via AT Command. Even when powered down the IC is able to pass a DTR signal received on the serial interface. Therefore an embedded application that monitors DTR, while the IC is powered down, can be made to wake up the IC, if a signal is received, by setting IO2 on the Radio Device high. 8.6 Controller Mode The Control Terminal, when powered up, will normally start up its GSM signalling software and look to register on the GSM network. Any embedded application script runs as a background process as and when the GSM software is idle. A feature available via embedded applications allows the Control Terminal to be placed in ‘controller mode’ whereby the Control Terminal powers up with a minimal subset of radio functionality. The GSM signalling software is halted and the embedded applications script has full control of the processor. Controller mode allows an application to run with more predictable response times. 40 LZ T123 7 605 P1C 9. SAFETY AND PRODUCT CARE 9. Safety and Product Care Please read the information in this section and the information in “Installation of the Control Terminal”, page 44, before starting your integration work. 9.1 Safety Instructions PLEASE READ THESE SAFETY INSTRUCTIONS AND KEEP A COPY OF THEM. • Always ensure that use of the Control Terminal is permitted. The Control Terminal may present a hazard if used in proximity to personal medical electronic devices. As a rule, the Control Terminal must not be used in hospitals, airports or planes. • Never use the Control Terminal at a gas station, refuelling point, blasting area or in any other environment where explosives may be present. • Operating the Control Terminal close to other electronic devices, such as antennas, television sets, and radios may cause electromagnetic interference. • This product is intended to be used with the antenna or other radiating element at least 20cm away from any part of the human body. In applications where this rule cannot be applied, the application designer is responsible for providing the SAR measurement test report and declaration. • You are responsible for observing your country's safety standards, and where applicable, the relevant wiring rules. 9.2 General Precautions • The Control Terminal as a stand alone item is designed for indoor use only. To use outside it must be integrated into a weatherproof enclosure. Do not exceed the environmental and electrical limits as specified in “Technical Data”, page 49. • Avoid exposing the Control Terminal to lighted cigarettes, naked flames or to extreme hot or cold temperature. • Never try to dismantle the Control Terminal yourself. There are no components inside the Control Terminal that can be serviced by the user. If you attempt to dismantle the Control Terminal, you may invalidate the warranty. • The Control Terminal must not be installed or located where the surface temperature of the plastic case may exceed 85° C. • All cables connected to the Control Terminal must be secured or clamped, immediately adjacent to the Control Terminal's connectors, to 41 LZ T123 7 605 P1C 9. SAFETY AND PRODUCT CARE provide strain relief and to avoid transmitting excessive vibration to the Control Terminal in the installation. • Ensure the d.c. cable, supplying power to the Control Terminal, does not exceed 3 metres. For longer distances please contact Sony Ericsson Service and Support. • To protect power supply cables and meet the fire safety requirements when the unit is powered from a battery or a high current supply, connect a fast 1.5A fuse in line with the positive supply. An appropiate fuse should be used see section “Power Supply”, page 45 • Do not connect any incompatible component or product to the Control Terminal. Note! Sony Ericsson may refuse warranty claims where evidence of product misuse is found. 9.3 SIM Card Precautions • Before handling the SIM card in your application, ensure that you are not charged with static electricity. Use proper precautions to avoid electrostatic discharges. • When the SIM card hatch is opened, the SIM card connectors lie exposed under the SIM card holder. Caution! Do not touch these connectors! If you do, you may release an electrical discharge that could damage the Control Terminal or the SIM card. • When designing your application, the SIM card’s accessibility should be taken into account. We always recommend that you have the SIM card protected by a PIN code. This will ensure that the SIM card cannot be used by an unauthorized person. 9.4 Antenna Precautions • If the antenna is to be mounted outside, consider the risk of lightning. Follow the instructions provided by the antenna manufacturer. • Never connect more than one Control Terminal to a single antenna. The Control Terminal can be damaged by radio frequency energy from the transmitter of another Control Terminal. • Like any mobile station, the antenna of the Control Terminal emits radio frequency energy. To avoid EMI (electromagnetic interference), you must determine whether the application itself, or equipment in the application’s proximity, needs further protection against radio emission and the disturbances it might cause. Protection is secured either by shielding the surrounding electronics or by moving the antenna away from the electronics and the external signals cable. 42 LZ T123 7 605 P1C 9. SAFETY AND PRODUCT CARE • The Control Terminal and antenna may be damaged if either come into contact with ground potentials other than the one in your application. Beware, ground potential are not always what they appear to be. 43 LZ T123 7 605 P1C 10. INSTALLATION OF THE CONTROL TERMINAL 10. Installation of the Control Terminal This chapter gives you advice and helpful hints on how to integrate the Control Terminal into your application from a hardware perspective. Please read the information given in “Safety and Product Care”, page 41 and then the read the information in this section before starting your integration work. 10.1 Where to Install the Control Terminal There are several conditions which need to be taken into consideration when designing your application as they might affect the Control Terminal and its function. They are: 10.1.1 Environmental Conditions The Control Terminal must be installed so that the environmental conditions stated in the Technical Data chapter, such as temperature, humidity and vibration are satisfied. Additionally, the electrical specifications in the Technical Data section must not be exceeded. 10.1.2 Signal Strength The Control Terminal has to be placed in a way that ensures sufficient signal strength. To improve signal strength, the antenna can be moved to another position. Signal strength may depend on how close the Control Terminal is to a radio base station. You must ensure that the location at which you intend to use the Control Terminal, is within the network coverage area. Degradation in signal strength can be the result of a disturbance from another source, for example an electronic device in the immediate vicinity. More information about possible communication disturbances can be found in section 10.3.5, page 47. When an application is completed, you can verify signal strength by issuing the AT command AT+CSQ. See the GR47/GR48 AT Commands Manual for more details. Tip! Before installing the Control Terminal, use an ordinary mobile telephone to check a possible location for it. In determining the location for the Control Terminal and antenna, you should consider signal strength as well as cable length 44 LZ T123 7 605 P1C 10. INSTALLATION OF THE CONTROL TERMINAL 10.1.3 Connection of Components The integrator is responsible for the final integrated system. Incorrectly designed or installed, external components may cause radiation limits to be exceeded. For instance, improperly made connections or improperly installed antennas can disturb the network and lead to malfunctions in the Control Terminal or equipment. 10.1.4 Network and Subscription • Before your application is used, you must ensure that your chosen network provides the necessary telecommunication services. Contact your service provider to obtain the necessary information. • If you intend to use SMS in the application, ensure this is included in your (voice) subscription. • Consider the choice of the supplementary services described in section “Short Message Service”, page 11. 10.2 How to Install the Control Terminal 10.2.1 Power Supply • Use a high-quality power supply cable with low resistance. This ensures that the voltages at the connector pins are within the allowed range, even during the maximum peak current. • When the unit is powered from a battery or a high current supply, connect a fast 1.5A fuse in line with the positive supply. This protects the power cabling and Control Terminal. 10.2.2 Securing the Control Terminal • Before securing the Control Terminal take into account the amount of additional space required for the mating connectors and cables that will be used in the application. • Where access is restricted, it may be easier to connect all the cables to the Control Terminal prior to securing it in the application. • Securely attach the Control Terminal to the host application using two 3mm diameter pan-head screws of appropriate length as shown below. Caution! Do not exceed a torque of 25Ncm when tightening the fixings screws. Excessive torque applied to the screws can crack the plastic case. 45 LZ T123 7 605 P1C 10. INSTALLATION OF THE CONTROL TERMINAL 10.3 Antenna 10.3.1 General The antenna is the component in your system that maintains the radio link between the network and the Control Terminal. Since the antenna transmits and receives electromagnetic energy, its efficient function will depend on: • the type of antenna (for example, circular or directional); • the placement of the antenna; • communication disturbances in the vicinity in which the antenna operates. In the sections below, issues concerning antenna type, antenna placement, antenna cable, and possible communication disturbances are addressed. In any event, you should contact your local antenna manufacturer for additional information concerning antenna type, cables, connectors, antenna placement, and the surrounding area. You should also determine whether the antenna needs to be grounded or not. Your local antenna manufacturer might be able to design a special antenna suitable for your the application. 10.3.2 Antenna Type Make sure that you choose the right type of antenna for the Control Terminal. Consider the following requirements: • the antenna must be designed for the dual frequency bands in use: EGSM 900/GSM 1800 for GT47, GSM 850/ GSM 1900 for GT48 • the impedance of the antenna and antenna cable must be 50Ω • the antenna output-power handling must be a minimum of 2W; • the VSWR value should be less than 3:1 to avoid damage to the Control Terminal. 10.3.3 Antenna Placement The antenna should be placed away from electronic devices or other antennas. The recommended minimum distance between adjacent antennas, operating in a similar radio frequency band, is at least 50cm. If signal strength is weak, it is useful to face a directional antenna at the closest radio base station. This can increase the strength of the signal received by the Control Terminal. The Control Terminal’s peak output power can reach 2W. RF field strength varies with antenna type and distance. At 10cm from the antenna the field strength may be up to 70V/m and at 1m it will have reduced to 7V/m. 46 LZ T123 7 605 P1C 10. INSTALLATION OF THE CONTROL TERMINAL In general, CE-marked products for residential and commercial areas, and light industry can withstand a minimum of 3V/m. 10.3.4 The Antenna Cable Use 50Ω impedance low-loss cable and high-quality 50Ω impedance connectors (frequency range up to 2GHz) to avoid RF losses. Ensure that the antenna cable is as short as possible. The Voltage Standing-Wave Ratio (VSWR) may depend on the effectiveness of the antenna, cable and connectors. In addition, if you use an adapter between the antenna cable and the antenna connector, it is crucial that the antenna cable is a high-quality, low-loss cable. Minimize the use of extension cables, connectors and adapters. Each additional cable, connector or adapter causes a loss of signal power. 10.3.5 Possible Communication Disturbances Possible communication disturbances include the following: • Noise can be caused by electronic devices and radio transmitters. • Path-loss occurs as the strength of the received signal steadily decreases in proportion to the distance from the transmitter. • Shadowing is a form of environmental attenuation of radio signals caused by hills, buildings, trees or even vehicles. This can be a particular problem inside buildings, especially if the walls are thick and reinforced. • Multi-path fading is a sudden decrease or increase in the signal strength. This is the result of interference caused when direct and reflected signals reach the antenna simultaneously. Surfaces such as buildings, streets, vehicles, etc., can reflect signals. • Hand-over occurs as you move from one cell to another in the GSM network. Your mobile application call is transferred from one cell to the next. Hand-over can briefly interfere with communication and may cause a delay, or at worst, a disruption. 10.4 Accessories The Control Terminal has been type approved together with a range of accessories including: Power Supply (GT47 only) 1. AC-DC Power Adaptor with customised d.c. lead (Model # AD-0901000BS) Input: 230Va.c., 50Hz, 2m mains lead (UK and Euro plug options) 47 LZ T123 7 605 P1C 10. INSTALLATION OF THE CONTROL TERMINAL Output: 9Vd.c., 1A. 2m d.c. lead with RJ11 connector. CE marked. Antennas (GT47 only) 2. Dual Band Minimag Antenna (900/1800MHz) (Model # 1140.26-FME/F) Magnetic-mount antenna, 0dB radiator, 2.6m RG174 cable with FME female connector. 3. Dual Band Antenna (900/1800MHz) (Model # EHD1890-FME/F) Bulkhead-mount antenna, 0dB radiator, 0.8m low loss cable with FME female connector. Cable (GT47 and GT48) 4. RS232 9-way Serial Cable (Model # C-E-RS232-2M) 2m, 9-way cable, DB9 (female) to DB9 (male) connectors. Please contact Sony Ericsson distribution channels for availability. 48 LZ T123 7 605 P1C 11. TECHNICAL DATA 11. Technical Data Data Features CSD Up to 9.6kbps, transparent and nontransparent HSCSD (2+1) Up to 28.8kbps GPRS Class B (4+1) - P channels - Coding schemes CS1 - CS4 85.6kbps (subject to network support and terminal location) GSM 07.10 multiplexing protocol Short Message Service Features SMS Text and PDU Point to point (MT/MO) Cell broadcast concatenation of up to 6 SMS Voice Features Full Rate, Enhanced Full Rate and Half Rate (FR/EFR/HR)/GT48 also (AMR) Adaptive Multi Role Echo Cancellation and Noise Reduction Dual Tone Multi Frequency (DTMF) Fax Features Group 3 Class 1 and 2 49 LZ T123 7 605 P1C 11. TECHNICAL DATA Data Storage SMS storage capacity 40 in the module In addition, the unit can handle as many SMS as the SIM can store Phone book capacity 100 Power Supply Supply voltage range 5 to 32V d.c. Radio Specifications Frequency bands GT47: EGSM 900 and GSM 1800 (dual band) GT48: GSM 850 and GSM 1900 (dual band) Maximum RF output power 2W (EGSM 900/GSM 1800) 1W (GSM 850/GSM 1900) Antenna impedance 50Ω Static sensitivity Better than –102dBm Audio Specifications Parameter Limit Output level (differential) ≥4.0Vpp Output level (dynamic load = 32Ω) ≥2.8Vpp Distortion at 1kHz and maximum output level ≤5% Offset, BEARP to BEARN ±30mV Ear-piece mute-switch attenuation ≥40dB Ear piece model Impedance Tolerance Dynamic ear piece [32Ω + 800µH] // 100pF ±20% Dynamic ear piece [150Ω + 800µH] // 100pF ±20% Piezo ear piece 1kΩ + 60nF ±20% 50 LZ T123 7 605 P1C 11. TECHNICAL DATA SIM Card Reader Voltage type Support for 3 V and 5 V SIM cards Electrical Connectors and LED Plug-in power supply RJ12 6-way connector and extended I/O Handset audio connector RJ9 4-way Antenna connector FME male RS232 port high density socket, 15 pin LED Green Mechanical Specification Length 77.4mm Width 66.4mm Height 26.2mm Weight <110g 51 LZ T123 7 605 P1C 11. TECHNICAL DATA Environmental specifications Operating temperature range –30°C to +75°C Storage temperature range –40°C to +85°C Relative humidity 5 to 95%, non-condensing Stationary vibration, sinusoidal Displacement: 7.5mm Acceleration amplitude: 20m/s² and 40m/s² Frequency range: 2 to 8Hz, 8 to 200Hz, 200 to 500Hz Stationary vibration, random Acceleration spectral density (m²/s²): 0.96, 2.88, 0.96 Frequency range: 5 to10Hz, 10 to 200Hz, 200 to 500Hz, 60min/axis Non-stationary vibration, including shock Shock response spectrum I, peak acceleration: 3 shocks in each axis and direction; 300m/s², 11ms Shock response spectrum II, peak acceleration: 3 shocks in each axis and direction; 1000m/s², 6ms Bump Acceleration: 250m/s² Free fall transportation 1.2m Rolling pitching transportation Angle: ±35degrees; period: 8s Static load 10kPa Low air pressure/high air pressure 70kPa/106kPa Current Consumption in Standard Operation Supply Voltage 5V 12V 32V Power Down Mode: Av Max Av Max Av Max 15 15 20 50 Frequency Av Max Av Max Av Max 850/900 MHz 1900/1800 MHz 26 26 110 120 43 45 Av Max Av Max Av 220 1230 170 960 90 70 520 350 40 30 mA Standby Mode (typical): 20 mA 19 mA Talk Mode (typical): Frequency 850/900 MHz 1900/1800 MHz Max 200 mA 140 mA Power Down Mode: DC power is applied but the Control Terminal is switched OFF. Standby Mode: The module is switched ON and attached on to the network. No call in progress. 52 LZ T123 7 605 P1C 11. TECHNICAL DATA Talk Mode: The module is switched ON and a voice/data call is in progress. The power consumption during transmission in Talk Mode is measured at maximum transmit power. The power consumption in Standby Mode is measured at the maximum paging rate (Paging Rate 2). Current Consumption with external +4.8V Supply Active For the following calculations it was assumed that the external +4.8V load is 70mA. Supply Voltage 5V 12V 32V Power Down Mode: Av Max Av Max Av 15 15 20 Max 50 mA Standby Mode (typical): Frequency 850/900 MHz 1900/1800 MHz Av Max Av Max Av 112 112 196 206 45 45 79 81 19 19 Av Max Av Max Av 306 1316 256 1046 126 106 556 386 53 43 Max 33 mA 32 mA Talk Mode (typical): Frequency 850/900 MHz 1900/1800 MHz Max 213 mA 153 mA These tables do not include the power consumption associated with any drive current supplied via further Control Terminal outputs, e.g. OUT-1 or OUT-2. 53 LZ T123 7 605 P1C 11. TECHNICAL DATA Current Consumption of UART Transceiver in Standard Operation with active/inactive serial Transmitter1 Note! It is assumed that every driving signal of the UART1 transceiver component inside the Control Terminal is driving an impedance of 3 KΩ to its output level of max. 5.4V (see data sheet of RS232 device: e.g. MAX3237). The signals that are driven are: RXD, CTS, DSR, DTR, RI Signal Voltage 5V 12V 32V 1.8 0.7 µA 0.4 0.15 mA 4.9 1.8 mA Power down mode of serial transmitter: 4.3 Serial transmitter active (no load): 0.9 Serial transmitter active (3 KΩ load): 11.7 Certification Directive 1999/5/EC EMC: EN 301 489-1 EMC: EN 301 489-7 Safety: EN 60950-1 GSM 3GPP TS 51.010-1 Tested according to GCF-CC 1) Internal reg ulato r effic ienc y >90% 54 LZ T123 7 605 P1C
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2003:08:19 11:05:21+01:00 Modify Date : 2003:08:19 11:05:21+01:00 Page Count : 54 Creation Date : 2003:08:19 10:05:21Z Mod Date : 2003:08:19 10:05:21Z Producer : Acrobat Distiller 5.0 (Windows) Author : graham.pearce Metadata Date : 2003:08:19 10:05:21Z Creator : graham.pearce Title : GT47 Integrators Manual.bookEXIF Metadata provided by EXIF.tools