Southco P101X Proximity Controller User Manual J EA P1 01 M revD
Southco,. Inc Proximity Controller J EA P1 01 M revD
Southco >
Users Manual
EA-P1 Proximity Controller Operating Instructions Package Contents Stand alone PIN + Prox Controller Operating instructions Wire harness for JA door access connector (9-wires with blue connector) Wire harness for JB lockout alarm connector (8-wires with white connector) Wire harness for JC tamper switch connector (3-wires with blue connector) Wire harness for JD external Wiegand reader connector (4wires with white connector) Diode (IN4007GW) 2 mounting screws EA-P1-01x Standalone Proximity Controller Specifications User Cards Supported: Supervisor Cards Supported: PIN Codes Supported: Power: Transmit Frequency : Card Reading Range: Default Access Time: Operating Temperature: Operating Humidity: Dimensions: 9,999 12VDC ± 10% 90mA maximum (standby mode), no attached devices 110mA maximum (operating mode), no attached devices 125kHz ASK (EM) up to 10 cm (depending on installation) 4 seconds 0-50 °C 20-90% RH, No condensation 118 mm x 75 mm x 19 mm Default Settings The table below describes the default settings of the EA-P1-01x controller. Description Access Time PIN Code Length Number of Failed Attempts Lockout Alarm Time Mode of Operation Default Value 4 seconds 4 digits 60 seconds card only Enrolling Supervisor Card To enroll the supervisor card: 1. 2. 3. 4. 1. 2. 3. Power ON LED Bicolor (red/green) Status LED PIN + Prox Controller Return to Ready State 4. Features Supports up to 9,999 user cards and five PIN codes Multiple modes of operation: card-only, card or PIN, card and PIN, bypass mode Programmable door release time (1 to 98 seconds) Programmable failed attempts (1 to 99) Programmable lockout time (1 to 98 seconds) Programmable user and supervisor code length (4 to 8 digits) LED indicators: Power and Status Supports connection to an external 26-bit Wiegand reader Non-volatile memory will retain data when power is removed Tamper switch For indoor use only Apply power to the unit. Switch the two DIP switches on the rear of the unit to “ON”. Hold the supervisor card to the unit. The status LED will flash red/green if the card has been successfully enrolled. Switch the two DIP switches on the rear of the unit to their original positions (“1” and “2”). To enroll additional supervisor cards, repeat Steps 1-3 above. Note that the last digit in the bottom right corner of the prox card must be different for each supervisor card (see below). xxxx xxxxxxxxxx 01234 56789 last digit NOTE: Once a supervisor card has been enrolled, it cannot be deleted. Controller Mounting and Installation Please refer to Southco trade drawing J-EA-P1-01 for mounting and installation details. J-EA-P1-01-M_revD visit www.southco.com for latest version of this document Page 1 of 4 EA-P1 Proximity Controller Operating Instructions Enrolling User Cards To delete a block of cards: User cards can be enrolled individually or in blocks. To enroll an individual user card: 1. 2. 3. Hold the supervisor card to the unit. Enter 6-6-6-6 on the keypad. Enter the last four digits on the bottom right corner of the prox card to be enrolled (example below). 1. 2. 3. 4. 5. Hold the supervisor card to the unit. Enter 7-7-0-0 on the keypad. Enter the last four digits of the lowest numbered card in the block to be deleted. Enter the last four digits of the highest numbered card in the block to be deleted. The unit will return to user mode when the status LED turns off or if the ‘*’ (return-to-ready state) key is pressed. For example, entering 7-7-0-0 8-3-0-0 8-3-0-5 will delete cards whose last four digits range from 8300 to 8305. Enrolling and Changing PIN Numbers xxxx xxxxxxxxxx 01234 Five PIN numbers can be enrolled. The default PIN number length is four digits. To enroll a PIN number: 56789 last 4 digits 4. 5. To enroll another card, repeat Step #3 while the status LED is still green. The unit will return to user mode when the status LED turns off or if the ‘*’ (return-to-ready state) key is pressed. 4. 5. Hold the supervisor card to the unit. Enter 6-6-0-0 on the keypad. Enter the last four digits of the lowest card in the block to be enrolled. Enter the last four digits of the highest card in the block to be enrolled. The unit will return to user mode when the status LED turns off or if the ‘*’ (return-to-ready state) key is pressed. For example, entering 6-6-0-0 8-3-0-0 8-3-0-5 will enroll cards whose last four digits range from 8300 to 8305. User cards can be deleted individually or in blocks. To delete an individual user card: 4. 5. Deleting PIN Numbers 1. 2. Hold the supervisor card to the unit. Enter 4-7-0-n on the keypad, where n is the slot number (range 1-5). To delete all PIN numbers: 1. 2. Hold the supervisor card to the unit. Enter 4-7-0-0 on the keypad. Changing PIN Number Length The default PIN number length is four digits. It can be programmed to be four to eight digits. To change the PIN number length: Deleting User Cards 1. 2. 3. 3. Hold the supervisor card to the unit. Enter 4-6-0-n on the keypad, where n is the slot number (range 1-5). Enter the desired four digit PIN number. PIN numbers may be deleted either individually or all at once. To delete an individual PIN number: To enroll a block of cards: 1. 2. 3. 1. 2. Hold the supervisor card to the unit. Enter 7-7-7-7 on the keypad. Enter the last four digits on the bottom right corner of the prox card to be deleted. To delete another card, repeat Step #3 while the status LED is still green. The unit will return to user mode when the status LED turns off or if the ‘*’ (return-to-ready state) key is pressed. 1. 2. Hold the supervisor card to the unit. Enter 4-8-0-d, where d is the number of digits in the PIN number (range 1-8). NOTE: Changing the PIN code length will not delete programmed PIN numbers. Changing the PIN code length to be longer than PIN numbers stored in memory will result in the PINs being unusable. For example, if a four digit PIN is stored in memory, and the PIN number length is then changed to eight, then the PIN cannot be used. However, if the PIN length is changed to be shorter than programmed J-EA-P1-01-M_revD visit www.southco.com for latest version of this document Page 2 of 4 EA-P1 Proximity Controller Operating Instructions PIN numbers already enrolled, then only the first d digits need to be entered to be granted access, where d is the newly programmed PIN code length. For example, if a four digit PIN has been programmed and the PIN code length is later changed to three digits, only the first three digits of the PIN need to be entered. Changing Number of Failed Attempts The default number of failed attempts is three. To change the number of failed attempts: 1. 2. Setting the Mode of Operation The unit can be set to one of four operating modes: Card-Only: Access granted when a valid card is held to the unit. This is the default mode. Card and PIN: Access granted when a valid card is held to the unit and then an enrolled PIN is entered. Card or PIN: Access granted when either a valid card is held to the unit or an enrolled PIN is entered. Bypass: Access granted until bypass mode exit command is issued. Hold the supervisor card to the unit. Enter 2-4-nn on the keypad, where nn is the desired number of failed attempts (range 01-99) Unless a valid user card is presented to the controller, the controller will assert the lockout alarm on the next failed attempt. Resetting the Unit Resetting the unit will restore the factory settings. It will not delete PIN numbers or enrolled user and supervisor cards. To reset the unit: 1. 2. Hold the supervisor card to the unit. Enter 0-8-0-0 on the keypad. To set the unit to operate in these modes: Auxiliary Input Card-Only 1. Hold the supervisor card to the unit. 2. Enter 3-2-0-0 on the keypad. The EA-P1-01x controller has an auxiliary input that can be connected to a momentary push-button. Pin 6 from the JA connector (green wire) is the auxiliary input. When the auxiliary input is 12VDC, the controller will grant access while the input is asserted plus the programmed access time. Connect a momentary push-button switch between the input lead and a 12VDC source to use this feature. NOTE: The unit will beep while the input is asserted. Card and PIN 1. Hold the supervisor card to the unit. 2. Enter 3-3-0-0 on the keypad. Card or PIN 1. Hold the supervisor card to the unit. 2. Enter 3-4-0-0 on the keypad. Lockout Alarm (JB Connector) Bypass Mode 1. Hold the supervisor card to the unit. 2. Enter 3-8-0-1 on the keypad to enter bypass mode (Enter 38-0-0 to exit bypass mode) NOTE: In all modes, access will be granted if the supervisor card is held to the unit and 3-6-0-1 is entered on the keypad. Changing Door Access Time The default door access time is four seconds. To change the access time: 1. 2. Hold the supervisor card to the unit. Enter 2-1-tt on the keypad, where tt is the desired door access time in seconds (range 01-98). NOTE: If 2199 is entered, the unit will allow access until a valid card/PIN is entered. Changing Lockout Alarm Time The EA-P1-01x controller provides a relay output that is activated when the keypad is locked out due to reaching the number of allowed failed attempts. This will cause the relay to close (i.e. drive the voltage at the COM terminal) for the programmed keypad lockout time. Tamper Switch (JC Connector) The JC connector can be used to monitor the status of the tamper switch. When the tamper switch is closed, the NO signal will be driven to the same voltage level as the COM signal. When the tamper switch is open, the NC signal will be driven to the same voltage level as the COM signal. See Wiring Diagram for pinout. Connecting to Wiegand Reader (JD Connector) The JD connector can be used to connect a 26-bit Wiegand reader to the EA-P1-01x. Supervisor and user cards do not need to be reenrolled to work with the Wiegand reader. NOTE: Only readers that provide a 26-bit Wiegand output are supported. See Wiring Diagram for pinout. The default door access time is sixty seconds. To change the access time: 1. 2. Hold the supervisor card to the unit. Enter 2-2-tt on the keypad, where tt is the desired lockout alarm time in seconds (range 01-98). NOTE: If 2299 is entered, the unit will continue to assert the lockout alarm until a valid card/PIN is entered. J-EA-P1-01-M_revD visit www.southco.com for latest version of this document Page 3 of 4 EA-P1 Proximity Controller Operating Instructions Wiring Multiple Controllers Wiring Diagram A diode is provided with the EA-P1-01x controller. The diode allows for a keypad to be isolated when multiple controllers are connected to the same latch. Refer to the figure below for wiring details when using the diode when using multiple controllers. Observe proper polarity when connecting the diode. NORMALLY OPEN (BROWN WIRE) OUTPUT, OR NORMALLY CLOSED (YELLOW WIRE) OUTPUT DIODE POLARITY MARK Connecting to an Inductive Load A diode is provided with the EA-P1-01x controller. This diode should be used when connecting to a device with an inductive load (for example, a relay or door strike) to protect the controller from a reverse voltage spike. The diode should be placed in parallel with the coil, as shown in the figure below. Observe proper polarity when connecting the diode. CAUTION: Product can be damaged if wired incorrectly. Follow wiring diagram above. CAUTION: A controller that has been programmed is nonreturnable. Please use caution in programming functions so as not to render the keypad unusable. NORMALLY OPEN (BROWN WIRE) OUTPUT, OR NORMALLY CLOSED (YELLOW WIRE) OUTPUT For technical support of this product contact: info@southco.com or visit: www.southco.com DIODE POLARITY MARK This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the installation, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio / TV technician for help You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1) 2) This device may not cause harmful interference and This device must accept any interference received, including interference that may cause undesired operation. J-EA-P1-01-M_revD visit www.southco.com for latest version of this document Page 4 of 4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Mode : UseNone XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 2011:06:22 11:48:45-05:00 Creator Tool : Microsoft Word - J-EA-P1-01-M_revD.doc Modify Date : 2011:06:23 14:51:43+08:00 Metadata Date : 2011:06:23 14:51:43+08:00 Format : application/pdf Creator : bargeb Title : Microsoft Word - J-EA-P1-01-M_revD.doc Producer : ScanSoft PDF Create! 4 Document ID : uuid:ba085ee6-c98b-4f6a-b850-f1319e68e747 Instance ID : uuid:fa5dc930-9da3-423c-b8c6-95c5befc9302 Page Count : 4 Page Layout : OneColumn Author : bargebEXIF Metadata provided by EXIF.tools