Spectrum 450241CBR Z-Wave Plus Module User Manual 912 Z Wave Plus indd

Spectrum Brands, Inc. Z-Wave Plus Module 912 Z Wave Plus indd

Users Manual 912

Download: Spectrum 450241CBR Z-Wave Plus Module User Manual 912 Z Wave Plus indd
Mirror Download [FCC.gov]Spectrum 450241CBR Z-Wave Plus Module User Manual 912 Z Wave Plus indd
Document ID3256792
Application IDLe40LmzG1SxEs5JL6JkXHQ==
Document DescriptionUsers Manual 912
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize289.82kB (3622722 bits)
Date Submitted2017-01-12 00:00:00
Date Available2017-01-12 00:00:00
Creation Date2016-05-24 10:06:51
Producing SoftwareAcrobat Distiller 15.0 (Windows)
Document Lastmod2016-05-24 10:06:51
Document Title912 Z-Wave Plus.indd
Document CreatorPScript5.dll Version 5.2.2
Document Author: SAD0418

66072-001
Rev 01
Z-Wave® Plus
Parts in the box
Latch
Exterior
Assembly
Interior
Assembly
ENGLISH
Installation and User Guide
“B” is not included. If needed,
please contact Kwikset to order
a drive-in latch for your lock.
4 AA Batteries
Ruler
Phillips head screwdriver
Fasteners
26298
22044
1-866-863-6584
www.kwikset.com
Keys
Spindle
Mounting
Plate
Kwikset
Technical Support
Additional Tools (depending on application)
Hammer
SmartKey
Tool
Strike
Required tools
Levers
27526
64156
F2
Wood block
Y2
Y1
Prepare the door and check dimensions
If drilling a new door, use the supplied template and the complete
door drilling instructions available at www.kwikset.com/doorprep.
Measure to confirm that the hole in
the door is 2-1/8" (54 mm).
Measure to confirm that the backset is
either 2-3/8" or 2-3/4" (60 or 70 mm).
2-3/8" or 2-3/4"
60 or 70 mm
See
note
below*
ba
ck
se
Measure to confirm that the hole in
the door edge is 1" (25 mm).
Measure to confirm that the door
is between 1-3/8" and 1-3/4" (35 mm
and 44 mm) thick.
1-3/8" – 1-3/4"
35 – 44 mm
1"
25 mm
2-1/8"
54 mm
*If you are installing this lever below
an existing lock or you plan to install a
lock above this lever, make sure that the
distance between holes is at least 6-1/2"
(165 mm).
actual
size
Install the latch and strike
Hold the latch in front of the door hole, with the
latch face flush against the door edge.
Is the door edge chiseled?
YES
NO
or
chiseled
not
chiseled
flush
slant of latch bolt faces
door frame
slant of latch bolt faces
door frame
Is the semi-circular hole of the latch centered in the door hole?
YES
NO
or
N (2x)
wood block
No adjustment is required.
Proceed to next step.
Move the pin to extend the latch.
Install strike on the door frame.
A/B
P (2x)
door frame
1/4
3
actual
size
Install the exterior keypad, mounting plate, and spindle
Install exterior keypad.
Route cable through mounting plate.
Secure mounting plate with
supplied screws.
keep parallel to
edge of door
cable goes
over latch
Install spindle.
rounded edge
faces latch
T (2x)
F2
tighten
screws
evenly
latch
actual
size
Install interior assembly
Remove battery cover and battery pack from interior assembly.
Remove battery cover.
Remove
battery
pack.
Install interior assembly onto mounting plate.
Connect cable.
Ensure tight cable connection.
Install 4 AA batteries into battery pack.
Install
battery
pack.
Ensure correct polarity.
For best results, use
new, non-rechargeable
Alkaline batteries only.
Push excess
cable back into
the door as you
install L.
Do not install
battery pack
into interior
assembly yet.
Secure with
screws.
U (2x)
Turnbutton
may need to
be turned to
install L.
Install levers
Install interior lever.
Secure interior lever.
Lever handle
faces away
from the latch.
Y1 or Y2
Push interior assembly onto
mounting plate.
Install exterior lever.
Secure exterior lever.
Lever handle
faces away
from the latch.
Tighten preinstalled set
screw.
Y1 or Y2
Test latch operation
Close door, test latch operation and make adjustments as needed:
If latch is loose in the strike, adjust the strike tab so it
grips the latch bolt better when the door is closed.
The small bolt of the latch should not enter the strike
hole. If it enters the strike hole, reposition strike.
small bolt in
strike hole
tab
small bolt NOT
in strike hole
2/4
Tighten preinstalled set
screw.
Pair the lock with your smart home system
If your controller is S2-compatible, please refer to the S2 Pairing Guide on the SmartCode 912 page at www.kwikset.com.
Initiate the pairing process at your smart
home controller. Refer to your smart home
system instructions for more information.
When prompted by your smart home system
to initiate pairing at the lock, press button “A”
on the lock interior one time. The red LED will
illuminate when pairing mode has been entered.
If the pairing process is successful, re-name
the lock in your system (if applicable).
If pairing is unsuccessful, follow your system's
instructions to remove the lock from the controller
and any other network, then press button “A” on the
lock one time.
button “A”
Perform steps 7A-7C again.
If pairing is still unsuccessful, consult the
Programming and Troubleshooting Guide on the
SmartCode 912 page at www.kwikset.com.
Please allow time for the controller to pair with the lock.
Add user codes (30 max)
It is recommended that you add and
delete all user codes through your smart
home control system. If your system
does not allow this, codes may be added
directly to the lock as shown here.
Make sure the door is open. Press
the Program button the number of
times that corresponds to the user
code position being programmed.
Programming Timeout
If no button is pressed for 5 seconds, the
system will time out and you will need to
restart the procedure.
Example: If
programming
the third code,
press the button
three times.
Enter user code. A total of 30 user
codes may be programmed.
Press Lock button once.
Each user code must
be a unique code
between 4 and 8 digits,
depending on your
smart home system.
What lights and sounds does the lock produce?
One green flash with one beep*
Three red flashes with three beeps*
or
1x
green
Two beeps*
or
3x
red
2x
Programming was unsuccessful.
Programming time out.
Make sure the user code is not a duplicate and that it is
between 4 and 8 digits during your next attempt.
Make sure not to pause for more than 5
seconds during programming.
Programming was successful.
*Beeping sound will only be heard if switch #3 (on the lock interior) is in the on positon. See “Switches and Status LED Colors” on page 4.
Mastercode
For enhanced security, a mastercode may be used when adding and deleting user codes. For more information about the mastercode, download the Programming
and Troubleshooting Guide on the SmartCode 912 page at www.kwikset.com.
Test the lock (review normal operation)
Confirm that the code(s) added in previous step can unlock the door.
Locking the Door
Unlocking the Door
Press Lock button once.
Enter user code.
Tip: You can press the
Lock button before
entering your user
code to light up the
keypad at night.
10
actual
size
Re-key the lock (if needed) and install the battery cover
Re-key the lock (if needed).
IMPORTANT:
Remove battery
pack before
re-keying.
Re-key the lock to work with your
existing key. See the supplied
SmartKey Re-key instructions
for more information.
Reinstall
battery
pack.
Install the battery cover.
V (2x)
3/4
Reference Guide
SmartCode at a Glance
System Alerts
Exterior
Alert
Reason
Solution
Keypad flashes red 1 time
with 1 beep*
Door jammed while
attempting to lock.
Manually re-lock door. If needed,
reposition strike.
Unsuccessful programming.
Attempt programming procedure
again.
One incorrect code entered.
Re-enter code.
No user code programmed.
Program at least one user code.
Low battery.
Replace batteries.
Programming timeout.
Attempt programming procedure
again, making sure not to pause for
more than 5 seconds.
Three incorrect codes entered
within one minute.
Re-enter code after 60 second keypad
lockout.
Interior (cover removed)
Keypad flashes red 3 times
with 3 beeps*
Button “A”
Button “B”
Back
panel
Keypad flashes red 10
times with 10 beeps*
Program
button
Keypad
Lock
button
SmartKey
tool hole
Lock beeps 2 times.
Switches
Status
LED
Keypad flashes red 3 times.
Keypad flashes red 6 times
with 6 beeps*.
Turnpiece
Keyway
Keypad flashes red 15 times
with 15 beeps*
*Beeping sound will only be heard if switch #3 is on.
Switches and Status LED colors
Deleting a user code
Switches
In order to delete a user code, you must override the code by adding a different user code in the same
position. For example, if you want to delete the third code, add a different user code in position three.
On Off
Status
LED
Test the old user code to make sure it can no longer unlock the door.
If you cannot remember the user code position, you may wish to perform a factory reset to delete all
codes associated with the lock.
1 2 3 4
Switch
Function
Color
Lock Status
Door lock status LED blinks every 6
seconds
Green
Unlocked
Lock automatically re-locks door 30
seconds after unlocking. Disabled if no
codes are programmed.
Amber
Locked
Red
Low battery
Audio
Not used.
Troubleshooting
A complete Programming and Troubleshooting Guide is
available on the SmartCode 912 page at www.kwikset.com.
Battery Replacement
Factory Reset
If another lock is installed above the lever, remove the interior
assembly when battery replacement is required.
A factory reset will delete all codes associated with the lock,
and it will remove it from your smart home system.
1 Remove
battery pack.
Lock
above
lever
2 Press and HOLD the Program
button while reinserting
the battery pack.
Keep holding the button for 30
seconds until the lock beeps
and the status LED flashes red.
Status
LED
Battery
pack
3 Press the Program button
once more. When the LED
flashes green and you
hear one beep, the lock
has been reset.
Interior
assembly
Mounting
plate
Network Information
4 Pair the lock with your smart home
system, and add user codes to your lock.
Important Safeguards
Removing the lock from the network
1.
2.
3.
4.
5.
Follow your smart home system’s instructions
to remove the lock from the network. When
prompted by the system, press button A” on the
lock interior once.
Read all instructions in their entirety.
Familiarize yourself with all warning and caution statements.
Remind all family members of safety precautions.
Protect your user codes and mastercode.
Dispose of used batteries according to local laws and regulations.
CAUTION: Prevent unauthorized entry. Since anyone with access to the back panel
can change the user codes, you must restrict access to the back panel and routinely
check the user codes to ensure they have not been altered without your knowledge.
The use of a mastercode can help protect your system’s settings.
Z-Wave System Notes
This product is a security enabled Z-wave Plus product and must be used with a Security
Enabled Z-Wave controller to be fully utilized. Z-Wave is a “Wireless mesh network,” and
results may vary based on building construction and communication path, with 35 feet+
being typical installed distance from smart home controller. It may be necessary to install
additional Z-Wave beaming capable devices that can serve as repeaters to enhance the
communication path between the lock and controller for a more robust Z-Wave network.
WARNING: This Manufacturer advises that no lock can provide complete security
by itself. This lock may be defeated by forcible or technical means, or evaded by
entry elsewhere on the property. No lock can substitute for caution, awareness of
your environment, and common sense. Builder’s hardware is available in multiple
performance grades to suit the application. In order to enhance security and reduce
risk, you should consult a qualified locksmith or other security professional.
To assure interoperability, each Z-Wave product must pass a stringent conformance test to
assure that it meets the Z-Wave standard for complete compliance with all other devices and
controls. The Z-Wave identity mark assures consumers, integrators, dealers and manufacturers
that their products will reliably perform with any other Z-Wave device. And, regardless of the
vendor, always powered nodes may act as a repeater for Kwikset/Weiser/Baldwin products.
Z-Wave Configuration and Association Parameters are available
on the SmartCode 912 page at www.kwikset.com.
4/4
© 2016 Spectrum Brands, Inc.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : SAD0418
Create Date                     : 2016:05:24 10:06:51-07:00
Modify Date                     : 2016:05:24 10:06:51-07:00
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.158975, 2016/02/13-02:40:29
Format                          : application/pdf
Creator                         : SAD0418
Title                           : 912 Z-Wave Plus.indd
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 15.0 (Windows)
Document ID                     : uuid:9fb1997d-bd13-42b0-a61d-30a93f7f5412
Instance ID                     : uuid:3bca26a5-cbf2-4a66-bd8b-82fff68c7ce2
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NUL450241CBR

Navigation menu