Spotwave Wireless SPOTCELL0001 Indoor unit (SCU unit) User Manual Installation manual

Spotwave Wireless Ltd. Indoor unit (SCU unit) Installation manual

Installation manual

SpotCell™ 100Quick Installation Guidewww.spotwave.comSpotwave Wireless Inc. 3701 Carling Avenue, Ottawa ON  K2H 8S2  Canada   Tel: (613) 820-0023   Fax: (613) 828-1956   E-mail: sales@spotwave.com© 2001 Spotwave Wireless Inc. All rights reserved. Printed in Canada
4. Installation Set the switch on the bottom of the SCU to “1” (install).Connect the power supply to the SCU, then plug the adapterinto the AC outlet.If required, more detailed information on installingSpotCell 100 can be found in the enclosed InstallationManual.5. Installation: DDUIn the location where the DDU is to be mounted, rotate theunit in a complete circle. The LED on the back will turn red or green during the rotation.6. Installation: DDUAgain rotate the DDU. When the LED turns green, stop therotation. This is the direction the DDU must face whenmounted. 9. Installation: SCUMount the SCU from a wall or ceiling, close to the centre of the area requiring coverage.2. LocationThe DDU can be mounted anywhereyour cell phone works. This may be on a rooftop (typical rural set-up), on theside of a building, or inside a building(typical downtown set-up). The SCU will be mounted inside the buildingwhere your cell phone does not work.(The illustrations at the right depicttypical installations.) To start the installation, place the DDU and SCU in the general areaswhere they are to be located. Do notphysically mount them at this time.3. InstallationConnect the DDU and SCU with the cable provided. For quick installation of SpotCell 100:For your safety, beware of power lines and ensure thatappropriate safety measures are maintained at all timesduring the installation of the SpotCell 100 equipment.Contact with high-voltage power lines could result in deathor serious injury.  10. Final Checklist1. Properly ground the DDU via the grounding bolt. 2. Ensure that there is a drip loop on the cable connectingto the DDU.  3. Firmly affix the cable to the building where it runsbetween the DDU and SCU.8. Installation: SCUMove the switch on the bottom of the SCU to “2” (active).Hold the SCU in the location to be mounted. The LCD on the bottom of the SCU indicates coverage by the number of bars; more bars indicate better coverage.Back of SCUBack of DDUCable connectorCable connectorGrounding boltPower supply connection: insert wires here whiledepressing blue tabs hereSwitch: install modepositionLEDDDU (outward-facing unit)SCU(indoor unit)Rotate 360° Rotate 360°7. Installation: DDUNow mount the DDU. Typical installations are pictured below.Wall Mount Pipe Mount with Hose Clamp1. Parts List• DDU • Cable (80'/25 m) • Mounting kit• SCU • Power supplyMounting bracketOptional bracket

Navigation menu