Stemco 8200000 RFID Reader User Manual A

Stemco LLC RFID Reader A

Contents

User Manual A

Download: Stemco 8200000 RFID Reader User Manual A
Mirror Download [FCC.gov]Stemco 8200000 RFID Reader User Manual A
Document ID803532
Application IDWCXvo/yQBfB+v1ktUCqPYQ==
Document DescriptionUser Manual A
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize195.94kB (2449278 bits)
Date Submitted2007-06-14 00:00:00
Date Available2007-06-15 00:00:00
Creation Date2007-06-14 15:54:53
Producing SoftwareXerox WCP C2128
Document Lastmod2007-06-14 15:55:22
Document TitleUser Manual A

User Reference Guide
Stemco Active HandBAT handheld Reader
Turning a unit on
When a HandBAT is first picked up the display will normally he turned off. To turn the
unit on press any key. If the display contrast appears too dark. or too light. press the
MAIN function key and then the right or left arrow keys to change the contrast. The
right arrow key each time it is pressed will darken the display. The left arrow key each
time it is pressed will lighten the display.
Main Menu
chain
Previous read
Configuration
11/04 08:223m
This screen is the Main Menu and is used to perform the intended functions of the RFID
handheld readeri Select the function you wish to perfomti You have three functions to
choose front. The primary function of the HandBAT is to Read parts. The second is
reviewing Previous readings infomation stored in the hand held device. The third is for
Configuring the hand held devicet
At. any timel and in my screen on the HandBAT, you can press the help key for
assistance.
Read part
This is the primary screen option used to read your BAT|RF tags installed on your
Vehicles. To activate this option press the up or down keys to highlight this option. then
press the Enter Key found in the middle of the upldown arrow keys, After depressing
the Enter Key you will be presented with the Read tags screen as shown below.
6/14/2007 Page 1
Tire pressure
Asset ID
Select the type of BAT|RF Sensor you wish to read at this titne. You have several
choices to choose from: Mileage tags, and AirBat sensors. Select your choice by using
the tip/down keys to highlight your desired Sensor type and pressing the Enter Key.
NOTE: Make sure you are within range of the sensor you are before
attempting to read. If several sensors can be seen at once it may be
necessary to get closer to the desired sensor so that you know which
sensor you are reading.
READING TracBnt mileage sensors
If you have a TrncBat mileage sensor. then use the up/down keys to highlight this menu
item. Point the hand held at the TraeBat you wish to read. and press the Enter Key. If the
tag is not within range or there is a problem with the tag. then you will get the Read
Failed screen as shown below.
c- Read failed
No RF DataTrac found.
Press Enter to retry
This may be caused by not holding your handheld reader within range of the TracBat mileage
sensor you wish to read. Please move to within the reading range and try again. If the
problem persists. and you cannot read the desired sensor. then Contact a Stentco sen'ice
specialist.
6/14/2007 Page 2
When a successful read of the TracBat has taken place. the following screen will appear
on the HandBATi This screen is the main information screen for the TracBat. There is a
sub-screen available which will read the trip mileage data from the sensor.
c- RF DataTrac
Rd# 16 11/04 08:29am
S/N 0187649/40 4
Life 0000000 km
Trip Press >
To read the trip mileage information. press the right arrow key. Note that the trip mileage
has a resolution of tenths of a mile. When you chose to get the trip mileage it will reread
the mileage sensor and return a screen similar to that shown below. At this point all the
life and trip information has been stored in the HxndBAT.
- RF Data'I‘ rac
Rd# 67 08/27 03:35pm
S/N 0187617/28 4
Life 0000014 mi
Trip 000014.3 mi
Reset trip Press A
Reset the trip mileage information that is stored in the Tchat sensor‘ by pressing the up
arrow key,
* Caution, this will erase the trip information stored In the TracBat.
When you press the up arrow key, the following screen will appear on the
HandBAT. At this point, all of the data for the current sensor being read hm been
stored in the HandBAT. and displayed.
6/14/2007 Page 3
a RF DataT rac
Rd# 67 08/27 03:35pm
s/N 0187617/28 4
Life 0000014 mi
Trip 000000.0 mi
Reset trip Press A
Trip Reset 0K
If you press the up arrow key‘ and the HundBAT finds a different sensor than the
original one being read. then the following message will appear.
-Read error
Found different RF
DataTrac.
Press > to retry
Move the HandBAT closer to the desired Tchal. and press the right arrow key again.
At this time the Trip Reset 0K screen should appear.
" If for some remion the trip mileage cannot be reset in the TrncBat, the following
screen will appear on the HandBAT.
IRF DataTrac
Rd# 67 08/27 03:35pm
S/N 0187617/28 4
Life 0000014 mi
Trip 000014.3 mi
Reset trip Press "
Trip Reset failed
READING Aerat sensors
6/14/2007 Page 4
C! Read
RE“ Dat aT rac
If you have an AirBat sensor. then use the upldown keys to highlight Tire pressure. Point
the HandBAT at the BATIRF AirBat sensor you wish to read. and press the Enter Key.
ll the sensor is not within range or there is a pmhlem with the sensor. then you will get
the Read Failed screen as shown below.
ClRead failed
Unable to read
tire pressure.
Press Enter to retry
This may be caused by not holding your HandBAT within the range of the Airbat. Please
move to within the reading range and try again. Contact Stcmco service specialist if you
cannot read a BATIRF sensor for any reason.
When a successful read of the BATIRF AirBat has taken place. the following screen will
appear on the HandBAT. This screen is the main information screen for the BATlRF
AirBat. Up to 4 AirBats sensors can be displayed at a time.
-Tire iressures
Readt‘l Data
71 100—801 PSI
73 85—781 PSI
This screen allows you to either read more AirBats or to look at the details of any of the
AirBat semsors that were read. To see the details use the up or down arrow key to
6/14/2007 Page 5
highlight the sensor of interest and press enterr The following screen will appear. The
data is now stored in the hand held reader for later viewing.
-Dual pressure
Rd# 73 08/27/04 15:52
S/N 0166422/10 4
Outer 85 PSI
Inner 78 PSI
Limits 85—115 PSI
Temperature 24 C
PSI limits press >
To change the pressure warning limits on the sensor press the right arrow key.
A screen similar to the one shown below will be displayed
CPSI limits
Low PSI limit 80
Hiih PSI limit 105
If you want to change the limits use the anew keys to navigate to the setting you want to
change. then press enter and you will be allowed to change the limits in 5 PSI increments
hy once again pressing the up and down arrow keys. When the limits have been set to the
desired values press the Enter Key which changes the default write settings then arrow
down to the write PSl limits line and press enter. This will write the limits to the desired
tag. The writing screen will be shown as portrayed below.
Writing . . .
Company Logo
Then you will be rctttmcd to the previous screen with a message about whether or not the
write was successful. If the write to the AirBat sensor works a screen similar to the one
shown below will be returned. If you now press the back key twice. and cursor up to the
61 14/2007 Page 6
Read more menu item. you can verify the limits have been set by pressing the Enter Key
while Read More is highlighted. The new limits should be shown on the screen.
-PSI limits
Low PSI limit 80
High PSI limit 105
Limits changed
However if the write failed a different screen will appear with the failed message. If you
should get the Write Failed message. you might move the hand held reader closer to the
sensor being written to. By pressing the Enter Key again. it will try and write out the
desired pressure limits.
-PSI limits
Low PSI limit 80
High PSI limit 105
Write failed
To retttm to the Main menu depress the MAIN key.
To return to the previous screen press the BACK key.
To get Help (additional directions) depress the HELP key.
Previous reads
VIEWING RECORDS
Each time you read any BATIRF tag. the data is stored in the HandBAT's intemal
memory. The data is assigned a read seguenee number. This allows the user to easily and
quickly retrieve tag data previously stored in the HandBAT. The memory can hold up to
400 records. When this memory is full the HandBAT will replace the oldest record in
the stored record list upon each new road event. This means that when the 401 record is
stored. record 1 is erased. and replaced with the data for 40]. Record 2 now becomes the
oldest record.
To view the records. from any screen. press the main key. This will return you to the
main screen. Using the up or down arrow keys. highlight the previous reads option in
the main menu and depress the Enter Key. The following screen will appear.
6/14/2007 Page 7
cnPrevious reads
Erase all records
Press the Enter Key. and the following screen will appear. The most recent record will
be displayed and highlighted. To View the detail data of any record. move the cursor up
or down to highlight the desired record. and press the Enter Key. The cursor moves up or
down one record each time the up or down arrow key is pressed. You can move down 5
records by pressing the right arrow key. or you can move up 5 records by pressing the left
arrow key.
-View records
Read# Data
71 100—0901 PSI
70 0013020 mi
69 0013010 mi
68 0010020 km
Highlight the desired record and press the Enter key. A sample record screen is shown
below.
-Dual pressure
Rd# 72 08/27/04 15:52
S/N 0166422/10 4
Outer 128 PSI
Inner 0 PSI
Limits 85—115 PSI
Temperature 24 C
This screen tells you the tag HandBAT either single or dual pressure monitory. It shows
the exact date and time of the read event and the BAT|RF lag serial number. The inner
and outer tire pressure, high and low pressure limits. and the temperature at the BATlRF
tag when the pressure was measured.
Press the back key to retum to the prcVious menu. The second item in on this page is the
Erase all Records feature.
6/14/2007 Page 8

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
Linearized                      : No
Page Count                      : 8
PDF Version                     : 1.6
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:cc7e9d9a-7c4a-4469-b445-7796cbe7cbc3
Modify Date                     : 2007:06:14 15:55:22-04:00
Create Date                     : 2007:06:14 15:54:53-04:00
Metadata Date                   : 2007:06:14 15:55:22-04:00
Document ID                     : uuid:70b4601d-4354-4ad6-a3f4-da545fb83dd1
Format                          : application/pdf
Producer                        : Xerox WCP C2128
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SRA-8200000

Navigation menu