Contents
- 1. User Manual A
- 2. User Manual B
User Manual A
User Reference Guide Stemco Active HandBAT handheld Reader Turning a unit on When a HandBAT is first picked up the display will normally he turned off. To turn the unit on press any key. If the display contrast appears too dark. or too light. press the MAIN function key and then the right or left arrow keys to change the contrast. The right arrow key each time it is pressed will darken the display. The left arrow key each time it is pressed will lighten the display. Main Menu chain Previous read Configuration 11/04 08:223m This screen is the Main Menu and is used to perform the intended functions of the RFID handheld readeri Select the function you wish to perfomti You have three functions to choose front. The primary function of the HandBAT is to Read parts. The second is reviewing Previous readings infomation stored in the hand held device. The third is for Configuring the hand held devicet At. any timel and in my screen on the HandBAT, you can press the help key for assistance. Read part This is the primary screen option used to read your BAT|RF tags installed on your Vehicles. To activate this option press the up or down keys to highlight this option. then press the Enter Key found in the middle of the upldown arrow keys, After depressing the Enter Key you will be presented with the Read tags screen as shown below. 6/14/2007 Page 1 Tire pressure Asset ID Select the type of BAT|RF Sensor you wish to read at this titne. You have several choices to choose from: Mileage tags, and AirBat sensors. Select your choice by using the tip/down keys to highlight your desired Sensor type and pressing the Enter Key. NOTE: Make sure you are within range of the sensor you are before attempting to read. If several sensors can be seen at once it may be necessary to get closer to the desired sensor so that you know which sensor you are reading. READING TracBnt mileage sensors If you have a TrncBat mileage sensor. then use the up/down keys to highlight this menu item. Point the hand held at the TraeBat you wish to read. and press the Enter Key. If the tag is not within range or there is a problem with the tag. then you will get the Read Failed screen as shown below. c- Read failed No RF DataTrac found. Press Enter to retry This may be caused by not holding your handheld reader within range of the TracBat mileage sensor you wish to read. Please move to within the reading range and try again. If the problem persists. and you cannot read the desired sensor. then Contact a Stentco sen'ice specialist. 6/14/2007 Page 2 When a successful read of the TracBat has taken place. the following screen will appear on the HandBATi This screen is the main information screen for the TracBat. There is a sub-screen available which will read the trip mileage data from the sensor. c- RF DataTrac Rd# 16 11/04 08:29am S/N 0187649/40 4 Life 0000000 km Trip Press > To read the trip mileage information. press the right arrow key. Note that the trip mileage has a resolution of tenths of a mile. When you chose to get the trip mileage it will reread the mileage sensor and return a screen similar to that shown below. At this point all the life and trip information has been stored in the HxndBAT. - RF Data'I‘ rac Rd# 67 08/27 03:35pm S/N 0187617/28 4 Life 0000014 mi Trip 000014.3 mi Reset trip Press A Reset the trip mileage information that is stored in the Tchat sensor‘ by pressing the up arrow key, * Caution, this will erase the trip information stored In the TracBat. When you press the up arrow key, the following screen will appear on the HandBAT. At this point, all of the data for the current sensor being read hm been stored in the HandBAT. and displayed. 6/14/2007 Page 3 a RF DataT rac Rd# 67 08/27 03:35pm s/N 0187617/28 4 Life 0000014 mi Trip 000000.0 mi Reset trip Press A Trip Reset 0K If you press the up arrow key‘ and the HundBAT finds a different sensor than the original one being read. then the following message will appear. -Read error Found different RF DataTrac. Press > to retry Move the HandBAT closer to the desired Tchal. and press the right arrow key again. At this time the Trip Reset 0K screen should appear. " If for some remion the trip mileage cannot be reset in the TrncBat, the following screen will appear on the HandBAT. IRF DataTrac Rd# 67 08/27 03:35pm S/N 0187617/28 4 Life 0000014 mi Trip 000014.3 mi Reset trip Press " Trip Reset failed READING Aerat sensors 6/14/2007 Page 4 C! Read RE“ Dat aT rac If you have an AirBat sensor. then use the upldown keys to highlight Tire pressure. Point the HandBAT at the BATIRF AirBat sensor you wish to read. and press the Enter Key. ll the sensor is not within range or there is a pmhlem with the sensor. then you will get the Read Failed screen as shown below. ClRead failed Unable to read tire pressure. Press Enter to retry This may be caused by not holding your HandBAT within the range of the Airbat. Please move to within the reading range and try again. Contact Stcmco service specialist if you cannot read a BATIRF sensor for any reason. When a successful read of the BATIRF AirBat has taken place. the following screen will appear on the HandBAT. This screen is the main information screen for the BATlRF AirBat. Up to 4 AirBats sensors can be displayed at a time. -Tire iressures Readt‘l Data 71 100—801 PSI 73 85—781 PSI This screen allows you to either read more AirBats or to look at the details of any of the AirBat semsors that were read. To see the details use the up or down arrow key to 6/14/2007 Page 5 highlight the sensor of interest and press enterr The following screen will appear. The data is now stored in the hand held reader for later viewing. -Dual pressure Rd# 73 08/27/04 15:52 S/N 0166422/10 4 Outer 85 PSI Inner 78 PSI Limits 85—115 PSI Temperature 24 C PSI limits press > To change the pressure warning limits on the sensor press the right arrow key. A screen similar to the one shown below will be displayed CPSI limits Low PSI limit 80 Hiih PSI limit 105 If you want to change the limits use the anew keys to navigate to the setting you want to change. then press enter and you will be allowed to change the limits in 5 PSI increments hy once again pressing the up and down arrow keys. When the limits have been set to the desired values press the Enter Key which changes the default write settings then arrow down to the write PSl limits line and press enter. This will write the limits to the desired tag. The writing screen will be shown as portrayed below. Writing . . . Company Logo Then you will be rctttmcd to the previous screen with a message about whether or not the write was successful. If the write to the AirBat sensor works a screen similar to the one shown below will be returned. If you now press the back key twice. and cursor up to the 61 14/2007 Page 6 Read more menu item. you can verify the limits have been set by pressing the Enter Key while Read More is highlighted. The new limits should be shown on the screen. -PSI limits Low PSI limit 80 High PSI limit 105 Limits changed However if the write failed a different screen will appear with the failed message. If you should get the Write Failed message. you might move the hand held reader closer to the sensor being written to. By pressing the Enter Key again. it will try and write out the desired pressure limits. -PSI limits Low PSI limit 80 High PSI limit 105 Write failed To retttm to the Main menu depress the MAIN key. To return to the previous screen press the BACK key. To get Help (additional directions) depress the HELP key. Previous reads VIEWING RECORDS Each time you read any BATIRF tag. the data is stored in the HandBAT's intemal memory. The data is assigned a read seguenee number. This allows the user to easily and quickly retrieve tag data previously stored in the HandBAT. The memory can hold up to 400 records. When this memory is full the HandBAT will replace the oldest record in the stored record list upon each new road event. This means that when the 401 record is stored. record 1 is erased. and replaced with the data for 40]. Record 2 now becomes the oldest record. To view the records. from any screen. press the main key. This will return you to the main screen. Using the up or down arrow keys. highlight the previous reads option in the main menu and depress the Enter Key. The following screen will appear. 6/14/2007 Page 7 cnPrevious reads Erase all records Press the Enter Key. and the following screen will appear. The most recent record will be displayed and highlighted. To View the detail data of any record. move the cursor up or down to highlight the desired record. and press the Enter Key. The cursor moves up or down one record each time the up or down arrow key is pressed. You can move down 5 records by pressing the right arrow key. or you can move up 5 records by pressing the left arrow key. -View records Read# Data 71 100—0901 PSI 70 0013020 mi 69 0013010 mi 68 0010020 km Highlight the desired record and press the Enter key. A sample record screen is shown below. -Dual pressure Rd# 72 08/27/04 15:52 S/N 0166422/10 4 Outer 128 PSI Inner 0 PSI Limits 85—115 PSI Temperature 24 C This screen tells you the tag HandBAT either single or dual pressure monitory. It shows the exact date and time of the read event and the BAT|RF lag serial number. The inner and outer tire pressure, high and low pressure limits. and the temperature at the BATlRF tag when the pressure was measured. Press the back key to retum to the prcVious menu. The second item in on this page is the Erase all Records feature. 6/14/2007 Page 8
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf Linearized : No Page Count : 8 PDF Version : 1.6 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:cc7e9d9a-7c4a-4469-b445-7796cbe7cbc3 Modify Date : 2007:06:14 15:55:22-04:00 Create Date : 2007:06:14 15:54:53-04:00 Metadata Date : 2007:06:14 15:55:22-04:00 Document ID : uuid:70b4601d-4354-4ad6-a3f4-da545fb83dd1 Format : application/pdf Producer : Xerox WCP C2128EXIF Metadata provided by EXIF.tools