Strata Proximity Systems SPS-UPROX Underground Proximity Generator User Manual Underground PAD Users Manual

Strata Proximity Systems LLC Underground Proximity Generator Underground PAD Users Manual

manual

Download: Strata Proximity Systems SPS-UPROX Underground Proximity Generator User Manual Underground PAD Users Manual
Mirror Download [FCC.gov]Strata Proximity Systems SPS-UPROX Underground Proximity Generator User Manual Underground PAD Users Manual
Document ID1571890
Application ID/jJ4oeTGhUoGjOBZV1RK5A==
Document Descriptionmanual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize80.77kB (1009646 bits)
Date Submitted2011-11-01 00:00:00
Date Available2011-11-02 00:00:00
Creation Date2011-10-19 09:26:08
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2011-10-19 09:26:08
Document TitleUnderground PAD Users Manual
Document CreatorMicrosoft® Office Word 2007
Document Author: Tom Michaud

2011
Strata Proximity Systems
Underground Proximity Generator
Users Manual v1.0
Strata Proximity Systems, LLC
1769 Jeff Road
Huntsville, AL 35806
1.800.691.6601
Strata Proximity Systems Underground Generator Users Manual v1.0
Confidentoial
Confidential and Proprietary
October 5, 2011
Table of Contents
Overview .............................................................................................................................3
1.1
Theory of Operation ......................................................................................................3
1.2
Frequency of Operation ................................................................................................4
1.3
Approvals ......................................................................................................................4
1.3.1
MSHA Approval ......................................................................................................4
1.3.2
Pennsylvania Approval ...........................................................................................4
1.4
Label Information..........................................................................................................4
1.5
FCC Information ............................................................................................................5
Operation ............................................................................................................................6
2.1
Installation Information ................................................................................................6
2.1.1
Interoperability Warning ........................................................................................6
2.2
Charging ........................................................................................................................6
2.3
Alerts ............................................................................................................................6
2.4
Maintenance .................................................................................................................6
Warranty .............................................................................................................................6
Revision History ...................................................................................................................7
4.1
Version 1.0 – October 5, 2011 .......................................................................................7
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 2 of 7
Strata Proximity Systems Underground Generator Users Manual v1.0
Confidentoial
Confidential and Proprietary
October 5, 2011
Overview
The Underground Proximity Generator is a component of the HazardAvert™ Proximity
Detection System from Strata Proximity Systems (SPS). HazardAvert™ provides warnings to
individuals and machinery to alert them that an individual wearing a portable alarm device has
entered too close to an operating piece of equipment and is in a dangerous situation.
HazardAvert™ also warns when vehicles or other machinery are getting close enough that the
possibility of a collision exists.
1.1
Theory of Operation
The Underground Proximity Generator is a component of HazardAvert™ and is mounted on
machinery such as Continuous Miners and Shuttle Cars and is connected to a central control
unit. The functions of the Underground Generator are:


To generate and transmit a 73kHz field around a vehicle or piece of machinery to act as a
protection zone for collision avoidance and for proximity detection for the protection of
individuals.
To receive a 916.48MHz RF signal from other vehicles or Personal Alarm Devices (PAD).
The Underground Proximity Generator Module generates a 73 kHz signal at the rate of 3mS on
and 3mS off at a repetition rate of approximately 200mS. This 73 kHz signal is fed to a wire /
ferrite radiator element which is integral to the Underground Proximity Generator Module. The
radiator produces a 73 kHz field that is emitted from the Underground Proximity Generator
Module. This field creates a protection zone around the vehicle or machine that can be
detected by other HazardAvert system components equipped with 73 kHz receivers. The
Underground Proximity Generator Module also has an internal 916.48MHz receiver for the
detection and demodulation of RF signals from other HazardAvert System components
equipped with a 916.48MHz transmitter. As the Underground Proximity Generator Module is
transmitting the 73 kHz field, other system devices are receiving the field and making
determinations as to their distance from the Underground Proximity Generator Module. If the
Underground Proximity Generator Module receives a 916.48 MHZ transmission in response to
its 73 kHz transmission, it analyzes the 916.48 MHz signal and determines if the transmitting
device is in what is considered a “Warning Zone” or a “Danger Zone”. If the Underground
Proximity Generator Module determines that the transmitting device is in a Warning or Danger
Zone area, it will turn on the appropriate LED’s to give a visual indication to individuals
operating or near the machine that the Warning or Danger condition exists. Information
regarding the received 916.48 MHz signal is also passed to a central controller on the vehicle or
piece of machinery.
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 3 of 7
Strata Proximity Systems Underground Generator Users Manual v1.0
Confidentoial
Confidential and Proprietary
1.2
October 5, 2011
Frequency of Operation
The Underground Proximity Generator will transmit on a frequency of 73 kHz and receive on a
frequency of 916.48 MHz
1.3
Approvals
1.3.1 MSHA Approval
The MSHA approval number is 18-PDA09003-0.
1.3.2 Pennsylvania Approval
The Pennsylvania approval number is BFE69-11.
1.4
Label Information
The Underground Proximity Generator label is located on the bottom face of the shunt. A
picture of the Strata and MSHA label is below:
The Strata label defines the model and serial number of the Underground Proximity Generator.
The MSHA label provides the MSHA approval number and specific MSHA certification.
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 4 of 7
Strata Proximity Systems Underground Generator Users Manual v1.0
Confidentoial
Confidential and Proprietary
1.4.1.1
October 5, 2011
MSHA Blasting Distance
MSHA approval requires that a minimum of 40 inches shall be maintained between the
Underground Proximity Generator and any blasting circuits, explosives or detonators.
1.4.1.2
Pennsylvania Blasting Distance
Pennsylvania approval requires that the Underground Proximity Generator must be installed at
a minimum safe distance of 17 feet from blasting circuits, explosives, and detonators.
Note: Pennsylvania generates such requirements by multiplying the MSHA determined
minimum distance of 40 inches by a factor of 5.
SPS magnetic field generators produce a magnetic field that at 100 kHz or .1000 MHz does not
achieve the Critical H Field until 1.42 m with a blasting cap having a pickup area of 10 sq.
meters.
SPS magnetic field generators are safe to 1.42 m from the blasting caps. SPS does recommend
a minimum distance of 25’ as a precaution.
1.5
FCC Information
The FCC ID for the Underground Proximity Generator is ZQ3-SPS-UPROX. When configured by
Strata for underground use, the device complies with Part 15 of the FCC Rules. Operation is
subject to the following conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received including interference that may
cause undesired operation.
Any intentional or unintentional changes or modifications to the configuration of the
Underground PAD not specifically detailed in this document could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 5 of 7
Strata Proximity Systems Underground Generator Users Manual v1.0
Confidentoial
Confidential and Proprietary
Operation
2.1
Installation Information
October 5, 2011
The Underground Proximity Generator is mounted on a vehicle or piece of machinery. Metal
near the Underground Proximity Generator may impact performance. After installing the
Underground Proximity Generator on the machine, performance of the unit should be verified
by calibration and test.
2.1.1 Interoperability Warning
The Underground Proximity Generator may experience erratic responses when in very close
proximity to some electronic devices. Electrical devices may transmit an electrical field and
noise from these fields may cause interference with the Underground Proximity Generator. A
safe guideline is to keep Underground Proximity Generator at least 75 mm away from any
electrical devices included but not limited to methane monitor, radio, mobile phone, PDA,
battery charger and laptop computers.
2.2
Charging
The Underground Proximity Generator is directly powered from the controller board and
requires no internal battery or charging.
2.3
Alerts
Although the Underground Proximity Generator has LED visual indicators, it is not designed to
alert the user. The LEDs are used mainly for set up and diagnostics of the system.
2.4
Maintenance
The Underground Proximity Generator should be regularly cleaned to reduce buildup of dust
and dirt.
Warranty
Initial system hardware components will be warranted to be free of defects for a period of one
(1) year from in service date. Subsequent component purchases will be warranted one (1) year
from receipt acknowledgement. Warranted replacement or repair is not applicable in cases of
physical damage or abuse as determined at the time of return or inspection.
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 6 of 7
Strata Proximity Systems Underground Generator Users Manual v1.0
Confidentoial
Confidential and Proprietary
Revision History
4.1
Version 1.0 – October 5, 2011
October 5, 2011
Original release. No revision history
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 7 of 7

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 7
Language                        : en-US
Tagged PDF                      : Yes
Title                           : Underground PAD Users Manual
Author                          : Tom Michaud
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2011:10:19 09:26:08
Modify Date                     : 2011:10:19 09:26:08
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZQ3-SPS-UPROX

Navigation menu