Strata Proximity Systems SPS-UTPAD Hazard Warning Transmitter for Miners User Manual Underground PAD Users Manual

Strata Proximity Systems LLC Hazard Warning Transmitter for Miners Underground PAD Users Manual

manual

Download: Strata Proximity Systems SPS-UTPAD Hazard Warning Transmitter for Miners User Manual Underground PAD Users Manual
Mirror Download [FCC.gov]Strata Proximity Systems SPS-UTPAD Hazard Warning Transmitter for Miners User Manual Underground PAD Users Manual
Document ID1555800
Application IDpRDr34qqAc0E3QANGhWGog==
Document Descriptionmanual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize89.2kB (1114987 bits)
Date Submitted2011-10-06 00:00:00
Date Available2011-10-07 00:00:00
Creation Date2011-09-07 15:04:35
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2011-09-07 15:04:35
Document TitleUnderground PAD Users Manual
Document CreatorMicrosoft® Office Word 2007
Document Author: Tom Michaud

2011
Strata Proximity Systems
Underground PAD Users Manual v1.0
Strata Proximity Systems, LLC
1769 Jeff Road
Huntsville, AL 35806
1.800.691.6601
Strata Proximity Systems Underground PAD Users Manual v1.0
Confidentoial
Confidential and Proprietary
September 1,
2011
Table of Contents
Overview .............................................................................................................................3
1.1
Theory of Operation ......................................................................................................3
1.2
Frequency of Operation ................................................................................................4
1.3
Approvals ......................................................................................................................4
1.3.1
MSHA Approval ......................................................................................................4
1.3.2
Pennsylvania Approval ...........................................................................................4
1.3.3
West Virginia Approval...........................................................................................4
1.4
Label Information..........................................................................................................4
1.5
FCC Information ............................................................................................................6
Operation ............................................................................................................................6
2.1
Installation Information ................................................................................................6
2.1.1
Interoperability Warning ........................................................................................7
2.2
Charging ........................................................................................................................7
2.3
Alerts ............................................................................................................................7
2.4
Buttons .........................................................................................................................8
2.5
Maintenance .................................................................................................................9
Warranty .............................................................................................................................9
Revision History ...................................................................................................................9
4.1
Version 1.0 – September 1, 2011 ..................................................................................9
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 2 of 9
Strata Proximity Systems Underground PAD Users Manual v1.0
Confidentoial
Confidential and Proprietary
September 1,
2011
Overview
The Underground PAD is a component of the HazardAvert™ Proximity Detection System from
Strata Proximity Systems (SPS). HazardAvert™ provides warnings to individuals and machinery
to alert them that an individual wearing the PAD has entered too close to an operating piece of
equipment and is in a dangerous situation. HazardAvert™ also warns when vehicles or other
machinery are getting close enough that the possibility of a collision exists.
1.1
Theory of Operation
The Underground PAD is worn by an individual. The functions of the Underground PAD are:



To detect the presence of a 73 kHz electromagnetic field generated by vehicles or machinery
equipped with the HazardAvert™ system and to determine if the field strength level detected
indicates that the individual is in or is approaching a dangerous situation.
To provide an audible and visual indication to the wearer of the Underground PAD when they
are approaching or are in a dangerous location as a result of the 73 kHz field strength level.
To transmit a 916.48 MHz RF signal to vehicles or machinery equipped with the HazardAvert™
system signaling that the individual is entering or has entered into a dangerous area relative to
the vehicle or machinery.
The Underground PAD has a 73 kHz receiver that is constantly on and monitoring the strength
of fields emitted by vehicles and machinery equipped with the HazardAvert™ proximity and
collision avoidance system. The Underground PAD monitors the strength of the 73 kHz fields in
three axis and determines if the field strength has risen to a level that would indicate that the
individual is approaching a “Warning Zone” or is in a “Danger Zone” due to being too close to
the vehicle or machinery. If the Underground PAD determines that the individual is too close to
the vehicle or machinery, it gives the individual both a visual and audible indication. At the
same time, the PAD transmits a 916.48 MHz RF signal to inform the vehicle or machinery that
the individual is approaching too close. If the Underground PAD determines that the field
strength indicates that the individual is not in a Warning or Danger Zone area, it will transmit a
data packet every ten (10) seconds via the 916.48 MHz with its status condition.
The Underground Pad is comprised of four systems each on a separate printed circuit board.
The PAD System Board contains three magnetic field pick-up coils each in a physically different
axis placed 90 degrees from each other. These pick-up coils along with their fixed value
capacitors and amplifiers form a 73 kHz receiver for reception of fields generated by vehicles or
machinery equipped with the HazardAvert™ system. The System Board also has a PIC
microcontroller which receives the inputs from three detectors which independantly detect the
inputs from the three 73 kHz pick-up coils. The PIC through an internal algorithm, determines if
the 73 kHz field is above a pre-programmed threshold.
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 3 of 9
Strata Proximity Systems Underground PAD Users Manual v1.0
Confidentoial
Confidential and Proprietary
September 1,
2011
If the PIC determines that the received field is above the threshold level, it sends a logic signal
and data to an internal RF Transmitter Board. The RF Transmitter Board contains a LINX TXM916-ES transmitter Integrated Circuit. The TXM-916-ES generates and frequency modulates a
916.48 MHz carrier with the data sent from the PIC microcontroller on the PAD System Board.
The RF Transmitter board has no alignment procedure as the TXM-916-ES treanmitter has a self
contained crystal controlled PLL oscillator. This transmitted 916.48 MHz signal will alert the
vehicle or machinery that generated the 73 kHz field that was received, that this particular
Underground PAD unit is coming within an unsafe distance of the vehicle or machinery. If the
PIC determines that the 73 kHz field strength is below the threshold level, it will cause the RF
Transmitter to transmitt the unit’s status and identification data once every 10 seconds.
Along with generating the RF signal to alert the machinery or device, the Underground PAD will
also alert the person wearing the PAD with both an audible sound and a visual indicator that
they are in an area that is too close to the vehicle or machinery. The audible and visual
indicators are located on a Warning Unit Board which is also within the Underground PAD.
1.2
Frequency of Operation
The PAD will transmit as a frequency of 916.48 MHz in the ISM Band.
1.3
Approvals
1.3.1 MSHA Approval
The MSHA approval number is HA-PAD-2100.
1.3.2 Pennsylvania Approval
The Pennsylvania approval number is BFE69-11.
1.3.3 West Virginia Approval
The West Virginia approval is expected Q4 2011.
1.4
Label Information
The Underground PAD label is located on the front center of the unit. A picture of the Strata
label and MSHA label is below:
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 4 of 9
Strata Proximity Systems Underground PAD Users Manual v1.0
Confidentoial
Confidential and Proprietary
September 1,
2011
The Strata label defined the Software (sw) version and Interface model number used inside the
PAD. The MSHA label provides the MSHA approval number, specific MSHA certification, serial
number and operational warning for fresh air charging only.
1.4.1.1
MSHA Blasting Distance
MSHA approval requires that a minimum of 40 inches shall be maintained between the
Underground PAD and any blasting circuits, explosives or detonators.
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 5 of 9
Strata Proximity Systems Underground PAD Users Manual v1.0
Confidentoial
Confidential and Proprietary
1.4.1.2
September 1,
2011
Pennsylvania Blasting Distance
Pennsylvania approval requires that the Underground PAD must be installed at a minimum safe
distance of 17 feet from blasting circuits, explosives, and detonators.
Note: Pennsylvania generates such requirements by multiplying the MSHA determined
minimum distance of 40 inches by a factor of 5.
1.5
FCC Information
The FCC ID for the Underground PAD is ZQ3-SPS-UTPAD. When configured by Strata for
underground use, the device complies with Part 15 of the FCC Rules. Operation is subject to
the following conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received including interference that may
cause undesired operation.
Any intentional or unintentional changes or modifications to the configuration of the
Underground PAD not specifically detailed in this document could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Operation
2.1
Installation Information
The Underground PAD is to be worn on the hip of the employee. Metal near the PAD may
impact the performance. The PAD should be at least 3 in or 75 mm from all other electronic
devices such as Spotters, CO sensors, tracking devices, etc. After placing the PAD on the
operator’s hip, performance of the unit should be verified at the SPS Checkout Station.
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 6 of 9
Strata Proximity Systems Underground PAD Users Manual v1.0
Confidentoial
Confidential and Proprietary
September 1,
2011
2.1.1 Interoperability Warning
The Underground PAD may experience erratic responses when in very close proximity to some
electronic devices. Electrical devices may transmit an electrical field and noise from these fields
may cause interference with the PAD’s reception. A safe guideline is to keep PAD at least 75
mm away from any electrical devices included but not limited to methane monitor, radio,
mobile phone, PDA, battery charger and laptop.
2.2
Charging
The Underground PAD is powered from an internal rechargable Lithiun Ion battery that is
connected to the other three boards through a Battery Interface Board. This Interface Board
contains a PIC microcontroller which provides switching functions to control power application
to the other boards as well as to determine when the PAD battery is being recharged. The
Battery Interface Board also contains circuitry necessary to allow the device to meet the
intrinsically safe requirements of mining equipment.
The PAD must be charged daily in an approved PAD charging station. The PAD will take
approximately 8 hours to charge when completely discharged. The PAD will operate for
approximately 48 hours after being fully charged.
2.3
Alerts
The Underground PAD will alert the user with both an audible sound and a visual indicator that
they are in an area that is too close to the vehicle or machinery. Once the PAD has determined
that the user is too close to the machine, it will begin to warn the user. Mulitple levels of
warning are provided. The typical setting is to give a warning when the user enters the
Warning Zone and as the machine aprroaches closer,the PAD crosses into the Danger Zone and
will alarm continuosly. A photograph of a PAD with its LED is shown below.
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 7 of 9
Strata Proximity Systems Underground PAD Users Manual v1.0
Confidentoial
Confidential and Proprietary
2.4
September 1,
2011
Buttons
Any user can stop all machines in their line-of-sight by using the Remote Stop capability
programmed into the Underground PAD. By simultaneously pressing any two of the three
buttons on the PAD for at least one (1) second, the PAD will transmit a Remote Stop signal to all
equipment in range of the PAD.
To cancel the Remote Stop, the operator must simultaneously press S1 and Menu on the PAD
for one (1) second.
A photograph of the top of the PAD and buttons is below.
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 8 of 9
Strata Proximity Systems Underground PAD Users Manual v1.0
Confidentoial
Confidential and Proprietary
2.5
September 1,
2011
Maintenance
The Underground PAD should be cleaned after each use to ensure all buttons and connectors
are free of all dust and dirt.
Warranty
Initial system hardware components will be warranted to be free of defects for a period of one
(1) year from in service date. Subsequent component purchases will be warranted one (1) year
from receipt acknowledgement. Warranted replacement or repair is not applicable in cases of
physical damage or abuse as determined at the time of return or inspection.
Revision History
4.1
Version 1.0 – September 1, 2011
Original release. No revision history
Patent #’s 7,420,471
5,939,986 and 6,810,353
Patent Pending
Page 9 of 9

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 9
Language                        : en-US
Tagged PDF                      : Yes
Title                           : Underground PAD Users Manual
Author                          : Tom Michaud
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2011:09:07 15:04:35
Modify Date                     : 2011:09:07 15:04:35
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZQ3-SPS-UTPAD

Navigation menu