Strategic Technologies STILOCK User Manual part3

Strategic Technologies Inc. part3

user manual part3

Download: Strategic Technologies STILOCK User Manual part3
Mirror Download [FCC.gov]Strategic Technologies STILOCK User Manual part3
Document ID24122
Application IDKga74QZ910fTKoO+3Kd5Fg==
Document Descriptionuser manual part3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize35.94kB (449297 bits)
Date Submitted1999-02-19 00:00:00
Date Available1999-08-13 00:00:00
Creation Date2001-07-05 11:16:02
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2001-07-05 11:16:04
Document Titleuser manual part3

PRU Installation - Classic
Use this method if you are going to use the standard installation technique.
1.
Plug in the PRU+: Plug one end of the AC Adapter into a 110 Volt AC Outlet and the other
end into the PRU+. The PRU+ will turn on, displaying the title screen. It will then display the
date and time screen. The power and charge LED will be lit. The charge LED will go out when
the unit is fully charged.
2.
Clear Stored Events: Press and hold the
PRU+ button on the LOCK until the PRU+
prompts “Please Wait....”. When the display prompts “B=Function Mode” press B button once.
The display will prompt “B=Clear Events”. Press B to clear all stored events. The display will
read “Events cleared”.
3.
Test for RF Signal Strength: Press “A” button twice. When the display prompts “B=Test
Mode”, press the “B” button to enter Test Mode. Look at the top line marked “RFStr”. The
display will have
a value on the top line that indicates the
signal strength
of the last transmission of the PID
displayed. The
value
is
representation
of the distance
the
PID
is
located
away
from the PRU+.
To reduce the
range the PRU+
will monitor the
participant set the RSSI setting in Extended Special Function Mode to this value minus 15%
(approx 30 points). Note: setting this value higher will reduce the size of the area of
confinement..
PID Installation
5.
Install the Battery: Remove the PID , baseplate, one strap, one locking bar, one locking pin
and the battery from the case. Simply place the battery into the PID battery well so that the
alignment mark on the battery lines up with the alignment mark on the PID. Rotate the battery
counterclockwise until the tabs on the battery slide under the two lock down posts. (See Figure
3 : installing the battery in the PID).
Figure 3: Installing the battery in the PID
6.
Size the Strap: Attach the wide end of the strap to the PID baseplate. With the baseplate on
the outside of the leg, wrap the strap around the participants leg, just above the ankle. Size the
strap so that it fits comfortably around the participant’s leg. Cut off any access strap that is
above the two hole positions that will fit into the other side of the strap (See Figure 4 : Strap
installation)
Figure 4 : Strap Installation
7. Install
Strap
and
PID:
Replace the baseplate and strap
around the leg, and attach the narrow end that has been cut to
length to the baseplate. Push the PID onto the baseplate at the
strap end. The PID is now hinged to the baseplate. Firmly close the PID and baseplate
together by pushing down on the open end.
Figure 5 : Attach the PID to the baseplate
8.
Install Locking Mechanism: Insert the slider bar under the strap into the hole in the side of
the PID (See Figure
6 : Slider Bar) so the end of
the slider bar is
flush with the strap. Press a
pin through the hole
in the strap and into the slider
bar. This locks the
PID together.
Figure 6 : Slider Bar
9.
Check Strap Tightness: Check the strap tightness on the side opposite the PID. There
should not be a space of more than ½ inch or 1.4 centimetres between the strap and the skin.
Installation Completion
10. Test the PID Signal: Watch the PRU+ in test mode, to ensure that the signal from the PID is
being received. The PID code number will be displayed and the PRU+ will beep to indicate it
has received the signal from the assigned PID. Note: during the first 5 seconds after the PRU+
receives the signal there will be a “+” immediately in front of the PID number. This will
disappear after 5 seconds. If the PID signal is not received within 1 minute, remove the PID
and check that the battery is properly installed.
11. Reset the PID: When a signal has been received by the PRU+, use the LOCK’s
PID
button to reset the alarms on the PID. Wait until the next signal from the PID. If the alarms has
been properly reset, the PID number will be displayed, with no icons following it.
12. Complete the Installation: On the PRU+, press the A button until “B=Exit” is displayed. Press
button B to exit. Connect the phone line to the wall and to the “LINE” jack on the PRU+. The
PRU+ will call the Central Computer. When “Call Successful” is displayed, remove the
telephone cable from the PRU+. Leave the AC Power adapter attached to the PRU+ but
unplug it from the wall outlet. The PRU+ can now be placed inside the participant’s home.
13. Position the PRU+: Remove the PRU+ and AC Adapter. Place the PRU+ in a central
location, preferably closer to the participant’s bedroom than their living area, elevated at least
three feet / ninety centimetres from the floor. Assure that the PRU+ is plugged into AC power
when it reaches the participant’s home (be careful that the AC outlet that the PRU+ is plugged
into cannot be switched off with a light switch).
Downloading Information inside the PRU+
1.
Connect AC: The information inside the PRU+ should be regularly downloaded (ie once per
week / once every two weeks). Connect the AC adapter to a wall outlet.
2.
Connect Telephone: Connect the telephone cable to the telephone outlet. The PRU+ should
immediately start to call the central computer.
3.
Wait for “Call Successful”: The PRU+ should indicate “Call Successful” when the PRU+ has
transferred all of the stored information. If the PRU+ does not indicate “Call Successful” the
PRU+ needs to call into the CC again. This can most easily be accomplished by removing the
AC plug from the wall until the PRU+ indicates “Starting Call..”. Once the PRU+ indicates
“Telephone In Use” plug the AC adapter back into the wall outlet.
De-Installation / Removal
A. If your equipment is monitored by our Monitoring Center:- Fax the Inactivation Form to the Monitoring Center on the same day that the unit is to be
removed from the participant’s residence.
B.
If you monitor your own equipment:- Assure the participant ‘s sentence ends on the same day that the unit is removed from the
participant’s residence.
1.
Connect AC Power & Telephone: Connect AC Power to the PRU+ by plugging the AC
adapter into a wall outlet. Connect the telephone into the telephone outlet. The PRU+ should
immediately start to call into the central computer.
2.
Wait for “Call Successful”: When the PRU+ indicates “Call Successful” the PRU+ has
transferred all of the stored information. If the PRU+ does not indicate “Call Successful” the
PRU+ needs to call into the CC again. This can most easily be accomplished by removing the
AC plug from the wall until the PRU+ indicates “Starting Call..”. Once the PRU+ indicates
“Telephone In Use” plug the AC adapter back into the wall outlet.
3.
Turn the PRU+ Off: Press and hold the
PRU+ button on the LOCK until “Please Wait...”
Is displayed on the PRU+. When “A=Turn PRU+ Off” is displayed, press button A on the PRU.
Disconnect the AC adapter from the wall. The PRU+ will turn off in approximately five (5)
seconds.
4.
Disconnect the PRU+: Disconnect the AC adapter from the back of the PRU+. Disconnect
the telephone cord from the PRU+ and wall jack. Place the PRU+, AC Adapter and telephone
cord into the carry / storage case.
5.
Remove the Pin and Slider Bar: Using a tool such as a small screwdriver, rotate the locking
pin on the PID all the way around two times (in both directions). This will break the locking pin
and will enable the slider bar to be removed.
6.
Remove the PID from the Baseplate: Remove the locking pin and slider bar. At the slider
bar end, lift the PID away from the baseplate (like opening a clam shell).
7.
Remove the Battery: Remove the battery from the PID by pulling it out of the battery well and
place it in the plastic container in the carry / storage case. DO NOT TRY TO TURN THE
BATTERY.
8.
Remove the Strap: Remove the strap from the baseplate. Replace the baseplate back onto
the PID and return the PID to the carry / storage case.
STRATEGIC Technologies Inc.
Domestic Violence
Domestic Violence
Unfortunately, issuing restraining orders does not assure safety to domestic violence victims.
Courts and law enforcement agencies enforcing stalking and domestic violence restraining orders
require assistance which the Platinum Plus 400 Series can supply. The offender, wearing a
transmitter, can continue to function in the community while complying to the restraining order. The
Personal Identification Device (transmitter) will act as a deterrent to the offender by enforcing the
realization they cannot approach the victim without activating an alarm. The victim is offered a
measure of security in that if the offender comes too close to their residence a priority alarm will be
sounded and there is a link to authority for immediate help.
The victim is given a Panic Alarm Pendant, and a PRU+ is installed in their place of residence. The
Personal Identification Device is worn by the offender. Another PRU+ should be installed at the
offender’s residence to enforce compliance with a curfew schedule and ensure that the offender
has not tampered or removed the transmitter. The information is entered into the central computer,
and is flagged as a priority domestic violence case.
The Panic Alarm Pendant transmitter code is programmed into the spousal code in the PRU+ and
the offenders PID code is programmed into the regular PID code (See Extended Special Function
Mode on page 38 For more information about programming these numbers). This will enable the
PRU+ to differentiate between a transmission sent by the pendant and the PID worn by the
offender.
STRATEGIC Technologies Inc.
Domestic Violence Installation
Domestic Violence Installation
Victims Installation
Pre-Installation
A. If your equipment is monitored by our Monitoring Center:- Fax the Enrollment Form to the Monitoring Center, giving as much time as possible (½
hour minimum) before the unit is to be hooked up inside the victims home. The Monitoring
Center must be notified before the unit calls in. The form should be clearly marked
indicating this unit is a domestic violence unit and is located in the victims home.
B. If you monitor your own equipment:- Assure you have entered the victims data on your system before you install the unit in the
offenders home. The curfew schedule should be entered with AWAY time all day. See
Page 50 For a complete listing of all events generated by the PRU+.
PRU+ Installation
1.
Position the PRU+: Remove the PRU+ and AC power adapter from the case. Place the
PRU+ in a central location, preferably closer to the participant’s bedroom than their living area,
elevated at least three feet / ninety centimetres from the floor.
2.
Plug in the PRU+: Plug one end of the AC power adapter into a standard 110 Volt electrical
outlet and the other end into the PRU+. Note : Do not connect the telephone line. The
PRU+ will turn on, displaying the title screen. It will then display the date and time screen. The
power and charge LED will be lit. The charge LED will go out when the PRU+ internal battery
is fully charged.
3.
Clear Stored Events: Press and hold the
PRU+ button on the LOCK until the PRU+
prompts “Please Wait....”. When the display prompts “B=Function Mode” press “B” button
once. The display will prompt “B=Clear Events”. Press “B”, the display will now prompt “A=**
Clear ** / B=Cancel”. Press “A” to clear all events.
Transmission Checks
Check the Participant’s PID
At this time, the PID that will monitor the offender should also be checked. This will verify that the
system operates correctly.
5.
Install the Battery: Remove the PID , baseplate, one strap, one locking bar, one locking pin
and the battery from the case. Simply place the battery into the PID battery well so that the
alignment mark on the battery lines up with the alignment mark on the PID. Rotate the battery
counterclockwise until the tabs on the battery slide under the two lock down posts. (See Figure
3 : installing the battery in the PID).
STRATEGIC Technologies Inc.
Domestic Violence Installation
Figure 3: Installing the battery in the PID
6.
Check PID Transmission: Press A twice then hit B to go into Test Mode. Hold the PID and
watch the PRU+ Test Mode Screen for a transmission from the PID. When the signal is
received it should indicate strap sever
symbol. The PRU+ should also beep to indicate
the PID has the correct code. When the transmission is received remove the battery by lifting
the battery out of the battery recess in the PID and place it in the plastic container in the
offenders carry / storage case.
Check the Pendant
7.
Check the Pendant Transmission: Push both pendant buttons. The Test Mode screen should
indicate a new transmission (with the code matching the pendant) by placing a + to the left of
the code.
Installation Completion
8.
Complete the Installation: On the PRU+, press the A button until “B=Exit” is displayed. Press
button B to exit. Connect the phone line to the wall and to the “LINE” jack on the PRU+. The
PRU+ will call the Central Computer. When “Call Successful” is displayed, installation is
complete.
9.
Install the offender’s unit: Follow the PRU+ Active Mode Installation instructions (Page 17,
44) for installing the PRU+ / PID set on the offender.
STRATEGIC Technologies Inc.
Domestic Violence Installation
De-Installation / Removal
A. If your equipment is monitored by our Monitoring Center:- Fax the Inactivation Form to the Monitoring Center on the same day that the unit is to be
removed from the offender’s residence.
B. If you monitor your own equipment:- Assure the offender ‘s sentence ends on the same day that the unit is removed from the
victim’s residence.
1.
Disconnect the PRU+: Disconnect the telephone cord from the PRU+ and wall jack.
Disconnect the AC adapter from the back of the PRU+
2.
Turn the PRU+ Off: Press and hold the
PRU+ button on the LOCK until “Please Wait...”
Is displayed on the PRU+. When “A=Turn PRU+ Off” is displayed, press button A on the
PRU+. Disconnect the AC adapter from the wall. The PRU+ will turn off in approximately five
seconds.
3.
Place in storage case: Place the PRU+, Pendant, AC adapter and telephone cord into the carry /
storage case.
STRATEGIC Technologies Inc.
Special Function Mode
Special Function Mode
The PRU+'s Special Function Mode allows the installer to change various configuration settings,
clear the stored events, and enter a test / diagnostic mode. To enter the Special Function Mode,
you use the LOCK. Simply press the
PRU+ button on the LOCK, while holding the LOCK
within three feet (1 metre) of the PRU+. The front panel display will show the message "Please
Wait....", and will then display two choices: "A=Turn PRU+ Off" and "B=Function Mode", as shown
below.
A-Turn PRU+ Off
B-Function Mode
The PRU+ can be turned off by pressing the “A” button on the front display of the PRU+. Pressing
the "B" button will enter function mode. The first function mode screen is displayed, as shown
below.
B=Clear
A=NextEvents
Function
B=Quick
A=NextInstall
Function
B=Test
A=Next
Mode
Function
Press the "B" button to clear all stored events in the PRU+'s memory. The display will prompt “A=**
B=EXIT
A=Next Function
Clear **”; press “A” to clear events. The message "Events Cleared!" will be displayed briefly.
Press the "A" button to move to the next screen.
Press “B” to enter the Quick Install function. Please refer to Quick Install on Page 44 for more
information. Press “A” to move to the next screen
Press the "B" button to enter Test Mode. Please refer to the section titled "Test Mode" on page 42.
Press the "A" button to move to the next screen.
This screen concludes the first set of program options. At this point, pressing the "B" button causes
the PRU+ to exit Special Function Mode and begin normal operation. Pressing the "A" button
returns the installer to the first screen (A=Turn PRU+ Off / B=Function Mode).
STRATEGIC Technologies Inc.
Extended Special Function Mode
Extended Special Function Mode
Extended Special Function Mode is used to change the internal settings inside the PRU+. The
ability to change the internal settings gives the PRU+ great flexibility. The installer can now change
important settings depending upon their needs.
Extended Special Function Mode can be accessed by moving to the screen “B=Exit” as shown on
pages 36 and 37. To access the extended configuration settings, hold down the
PRU button
on the LOCK. Once a small dot begins to flash in the right top corner of the display press the "A"
button. This will cause the PRU+ to display the configuration screen, as shown in the next diagram.
A=Next Function
B=Dial Mode
This screen allow the installer to change the way the PRU+ dials. The PRU+ can dial both pulse
and tone. Select the mode that is appropriate for your telephone network. Press the “B” button to
change the dial mode between “T” (tone dialling) and “P” (pulse dialling). Press the “A” button to
move to the next screen.
A=Next Function
B=Dial Prefix: N
B#1,8001231234
A=Next Function
If the PRU+ is installed in an office or a hotel, the telephone system may require an additional digit
to be dialled to access an outside line. Pressing the “B” button changes the prefix between “N”
which indicates “No Prefix” required to a “digit” from 0 to 9. Stop pressing the “B” button when the
prefix required is reached. Press “A” button to proceed to the next function.
This screen allows the installer to change the telephone number that the PRU+ will dial to call the
Central Computer. When this screen is displayed, pressing the "A" button will move to the next
screen. If the "B" button is pressed, a flashing cursor is displayed over the first character of the
telephone number. This indicates that the display is now in "edit mode". While in edit mode,
pressing the "B" button will change the character under the cursor. Pressing the "B" button
repeatedly will cycle through the valid characters (0-9, a # symbol, a * symbol, a comma - used to
insert a two-second pause into the dialling sequence; or a space - to erase unnecessary
characters). While in the edit mode, pressing the "A" button steps through the character positions
from left to right, until the last (fourteenth) character is reached. At this point, pressing the "A" button
will cause the screen to exit “edit mode” and move to the next option.
STRATEGIC Technologies Inc.
Extended Special Function Mode
B=Set
A=Next
RSSI
Function
100
This screen enables the installer to limit the range the PRU+ will detect the presence of the PID. If
transmissions are received from the PID with a signal strength less than the value set the
transmission will be ignored. The value may be set between 0 - 255. A value of 0 indicates all
transmissions will be valid. To set the value press B and a cursor will appear under the first digit of
the setting. Press B to increment the current digit and press A to move to the next digit.
A=Next Function
B=Set PID# 30431
This screen allows the installer to change the number of the PID installed on the participant. This is
useful for cases where the supplied PID has been lost or broken, and a replacement PID with a
different code must be used. This screen operates similarly to the telephone number screen. When
this screen is displayed, pressing the "A" button will move to the next screen. If the "B" button is
pressed, a flashing cursor is displayed over the first character of the PID code. This indicates that
the display is now in "edit mode". While in “edit mode”, pressing the "B" button will change the
number under the cursor. Pressing the "B" button repeatedly will cycle the digit under the cursor
from 0 to 9. NOTE: code numbers such as "68" must be entered as "068". While in the edit mode,
pressing the "A" button steps through the digits from left to right, until the third digit is reached. At
this point, pressing the "A" button causes the screen to exit “edit mode” and move to the next
option.
A=Next Function
B=Set Leave 03
This screen allows the installer to change the leave window for the PRU+. The leave window is the
period of time which the PRU+ allows to elapse without receipt of any transmissions from the PID
before a "Leave" message (ie ..info leave or ALARM AWAY) is registered. Pressing the "B" button
repeatedly steps through the possible values (3-30). Pressing the "A" button causes the next screen
to be displayed.
B=SpsCode#
A=Next Function
30253
This screen allows the installer to change the code of the Domestic Violence Deterrent pendant (if
B=DateFormat
A=Next Function
YMD
applicable) This setting allows the PRU+ to differentiate between the transmitter worn by the
offender and the pendant used by the victim. Different Alarm indications will be reported by the
PRU+ dependant on which code is received. See Individual Status Log Reports on Page 50 for
detailed explanations on these events.
STRATEGIC Technologies Inc.
Extended Special Function Mode
This screen allows the installer to change the format of the date displayed by the unit during normal
operation. Pressing the "B" button repeatedly will cycle through the available options: YMD
(year/month/day), MDY (month/day/year), or DMY (day/month/year). Press the "A" button to move
to the next screen.
B=Set
A=Next
YearFunction
98
B=Set
A=Next
Month
Function
10
B=Set
A=Next
DayFunction
08
B=Set
A=Next
HourFunction
12
B=Set
A=Next
MinFunction
30
This screen allows the installer to change the year setting on the internal clock. Pressing the "B"
button changes the year number. Pressing the "A" button causes the next screen to be displayed.
NOTE: The clock is automatically updated by the Central Computer during a PRU+ call-in, to keep
the PRU+ and central computer clocks synchronized.
This screen allows the installer to change the month setting on the internal clock. Pressing the "B"
button changes the month number. Pressing the "A" button causes the next screen to be displayed.
This screen allows the installer to change the day setting on the internal clock. Pressing the "B"
button changes the day number. Pressing the "A" button causes the next screen to be displayed.
This screen allows the installer to change the hour setting on the internal clock. (This is based on a
24 hour clock.) Pressing the "B" button changes the hour number. Pressing the "A" button causes
the next screen to be displayed.
This screen allows the installer to change the minute setting on the internal clock. Pressing the "B"
button changes the minute number. Pressing the "A" button causes the next screen to be displayed.
STRATEGIC Technologies Inc.
Extended Special Function Mode
B=EXIT
A=Next Function
This final screen allows the installer to exit extended special function mode. Pressing the "A" button
returns the installer to the very first screen (“A=Turn PRU+ Off / B=Function Mode”). Pressing the
"B" button causes the PRU+ to exit Special Function Mode and resume normal mode. All settings
are automatically saved at the time they are entered.
STRATEGIC Technologies Inc.
Test Mode
Test Mode
Test Mode which is accessed from the Special Function Mode screens is useful for many diagnostic
tests. Selecting test mode causes the screen shown below to be displayed.
Figure 1 : Test Mode Display
The top line of the display is the signal strength of the last transmission received from the PID along
with the channel received.
The left half of the bottom line provides PRU+ status information. The two symbols at the left edge
of the display are status indications:
AC Power -
indicates the AC power adapter has been properly connected and
plugged into a standard functioning 110 volt AC electrical outlet.
Telephone Line -
indicates that the PRU+ has been connected to a properly functioning
telephone line.
The two symbols to the right of the AC power and telephone indications represent the following
alarm conditions:
PRU+ Tamper indicates the PRU+ case is open or has been seriously
damaged.
PRU+ Motion -
indicates the PRU+ is moving or tilted.
Low PRU+ Battery- indicates that the PRU+'s internal battery is approaching the
limits of sustained operation (applicable only when AC power is not
connected).
The right half of the bottom line provides information on transmissions received from PIDs. The fivedigit number shown is the PID code of the last received transmission (see Note below). If a '+' is
shown next to the PID serial number, this indicates that the transmission was received within the
last 5 seconds. After the + symbol expires, the position on the display will indicate if the serial
number is assigned to either the PID monitored by the PRU+ (a ‘T’ will be displayed) or the
domestic violence pendant (an ‘S’ will be displayed). If the
PRU+ button is pressed on the
LOCK the serial number will change to display “LOCK”.
STRATEGIC Technologies Inc.
Test Mode
The symbols to the right of the code number provide the following information:
PID Case Open -
indicates the last received transmission showed a case open alarm.
Strap Sever -
indicates the last received transmission showed a strap cut alarm.
PID Tamper -
indicates the last received transmission showed a strap tamper alarm
(the strap has been damaged other than being cut all the way
through)
Low PID Battery indicates the battery installed in the PID which sent the last
transmission is approaching the limits of its lifetime or is improperly
installed.
NOTE: The test mode will receive and display transmissions from ALL PID's within range of the
PRU+. If a transmission is received from the PID which is assigned to the PRU+, the PRU+ will
beep.
STRATEGIC Technologies Inc.
Test Mode

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2001:07:05 11:16:02
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2001:07:05 11:16:04+01:00
Page Count                      : 16
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OEHSTILOCK

Navigation menu