Sun Castle Global Precision Technology Co SCGPTDL0003 Electronic RFID & Keypad Door Lock User Manual

Sun Castle Global Precision Technology Co, Ltd. Electronic RFID & Keypad Door Lock Users Manual

Users Manual

Before AfterProduct Overview The picture is for reference only. Please check the actual model for specific functions.Exterior plate(Outside view)Interior plate(Inside view)Setting ButtonUp Button:Use it to add new keycards/PIN codesDown Button:Use it to delete keycards/PIN codesBattery CoverUse the special tool providedto openSensorKeypadPIN codes consist of 4~8 digits, numbers can be repeatedConfirm/Exit ButtonSelect ButtonKeyhole CoverHorizontally position the key and turn the keyhole cover 90  clockwise to remove it then unlock with the key  --Accessories--Emergency Override Key3 keys provided per lock RFID KeycardsDoor Lock StatusTypeAdministratorUserSingle-Entry UserVolumeQuantity Function No. Instruction4 sets94 sets1 set1 setAdd/Modify/DeleteUnlock the doorCan be used only onceSound volumeUnlocking Keycards or PIN codes.Keycards or PIN codes be used only once.Types of No.StatusOperation SuccessfulOperation FailedEnter/ Exit Setup ModeLow BatteryDoor Opened IndicationDoor Closed IndicationLightBlueRedBlue / RedRed1 beep3 beeps2 beeps5 continuous beepsSounds1 beep after the right Keycard or PIN code that the lock is open.After depressing the lever, the door is locked 1.5 seconds after the lever comes back to the horizontal position.Unlocking MethodsNotice.The factory default admin. PIN code is 123456. It is highly recommended to change  the     admin. code upon installation of the lock..Only one PIN code or one Keycard can be set per No. of location..Please turn to the last page to restore to the factory default settings..There is no need to reset PIN codes or Keycards after battery replacement. •The setup mode cannot be entered during the passage mode.1.Mechanical Key : Horizontally position the key and turn the keyhole cover 90 degrees  clockwise to remove it then unlock with the key.2.Keycard : Press any button to enter the system, simply place the RFID card to the sensor.3.PIN Code : Press any button to enter the system, enter assigned PIN code and press      to confirm.4.Passage Mode : Place the RFID card to the sensor or enter assigned PIN code and press                  . Press       to lock.#*#*#00~03*04~97*98*99*Electronic RFID & Keypad Door LockSKR600Operation ManualSKR600 SpecificationDimension -- Panels:290(H) x 70(W) x 72 (D)-(mm)Approximate Weight:4520 gUse 4AA Alkaline batteries (1.5V)Others:RFID Sensor Digital Pad (Metal & Waterproof)Door Thickness:45mm ~ 55mm56mm ~ 80mmStandard US Mortise LockbodyTemperature:-10  C ~ 70  C
Enter the Setup ModeEnter theSetup ModeAdministrator RecognitionAdministrator *Press the No.    00~    99*Press the No.EnterExit Setup ModeExit Setup ModePIN Code/ RFID Keycard Setup1. The admin. and user PIN code cannot be 000000/111111/123456.2. Blue light flashes if the setup location has been occupied.Notice3. 3 beeps (red light) mean operation failure.4. If no actions are taken over 5 seconds during the setup mode, the system will exitautomatically with two beeps (blue light).User Setup13452#Press the Up Button on the back of the lock for 2 seconds until hear two beeps.Input admin. PIN code and then press      to confirm or position the admin. card to the sensor.#04 ~      97**Press the No. Enter the intended PIN code (consistsof 4-8 digits), and then press       to confirm or position the card to the sensor.#Single-Entry User SetupOther SetupUser Deletion1 2 3 4#Press the Down Button on the back of the lock for 2 seconds until hear two beeps.Input admin. PIN code and then press     to confirm or position the admin. card to the sensor.#Enter the No. you intend to delete (    01 ~     97),and then press    to confirm or position the card.#**Volume Setup1 2 3 4 5#Press the Up Button on the back of the lock for 2 seconds until hear two beeps.Input admin. PIN code and then press to confirm or position the admin. card to the sensor.#Press the No.        99*Press 00(mute), 01(low), 02(medium) or 03(loud), and then pressto confirm.#1 2 3 4All User Deletion#Press the Down Button on the back of the lock for 2 seconds until hear two beeps.Input admin. PIN code and then press     to confirm or position the admin. card to the sensor.#Press the Down Button on the back of the lock for 5 seconds until hear a continuous beep and two short beeps mean successful reset.Factory Default SettingProblemContinuous beeps after successful operationNo reaction when entering Keycards/ PIN codesLight doesn’t go offLow battery alert. Please replace  batteries immediately.Batteries are dead. Please use the key to unlock.Consecutive Keycards/PIN codes entry errors. Pleae try again after 1 minute.Replace batteries.IndicationTroubleshootingImportant Notes13452#Press the Up Button on the back of the lock for 2 seconds until hear two beeps.Input admin. PIN code and then press      to confirm or position the admin. card to the sensor.#Press the No.      98*Enter the intended PIN code (consistsof 4-8 digits), and then press       to confirm or position the card to the sensor.#Administrator Setup - First time setup13452#2Press the Up Button on the back of the lock for 2 seconds until hear two beeps.Input the factory default admin. PIN code (123456) and then press      to confirm.#Input admin. PIN code and then press      to confirm or position the admin. card to the sensor.#00/     0102/     03****Press the No. Enter the intended admin. PIN code (consists of 4-8 digits), and then press     to confirm or position the admin. card to the sensor.#- Admin. already setup1. Remove one battery.2. Next, while continuously pressing the two buttons on the back, reinstall thebattery.A continuous beeps (red light) and a short beep (blue light) after successfuloperation.1. If the Keycard is lost, please delete it right away.* Notice:The administrator (*00) can’t be deleted individually.2. Please use alkaline batteries only.  Do not mix using old and new batteries.3. The battery leakage will cause damage of the product.  Please makeregular inspections of battery leakage.4. Use a clean and dry cloth to preserve the cleanliness of the product.  Donot use alcohol or othe rchemical agents.5. If you encounter any problems, please refer to the user manual first. If youstill have questions, please feel free to contact us or email us.Enter the Intended PIN Code or CardRecognitionEnter theSetup ModeAdministrator  Enter ExitSetup ModeRecognition
Federal Communication Commission Interference StatementThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:. Reorient or relocate the receiving antenna.. Increase the separation between the equipment and receiver.. Connect the equipment into an outlet on a circuit different from that to which the receiver is       connected.. Consult the dealer or an experienced radio/TV technician for help.FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices).This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

Navigation menu