ShangHai Sunray Technology Co.,Ltd
SRWF-8009 Wireless Meter Reading Module User
Manual
Version 2.0
1 / 17
ShangHai Sunray Technology Co.,Ltd
Content
1.
2.
3.
6.
7.
8.
9.
Product Overview ................................................................................................................................. 3
Electric Characteristics and Parameter ................................................................................................. 3
Software Function ................................................................................................................................ 5
3.1.
Measurement ............................................................................................................................ 5
3.2
Communication Function ......................................................................................................... 8
3.3
Valve Control Function ............................................................................................................ 8
3.4
Battery voltage detection function............................................................................................ 9
3.5
Alarm function ....................................................................................................................... 10
Brief Introduction of Compatibility.....................................................................................................11
4.1.
Pulse Closing Time Requirements...........................................................................................11
4.2. Pulse Number Requirements ...................................................................................................11
4.3.
Valve Requirements .................................................................................................................11
Structure and Installation Size ............................................................................................................ 13
5.1. Structure of the Module .......................................................................................................... 13
5.2. Installation Size of the Module............................................................................................... 13
Communication Tools ........................................................................................................................ 14
6.1. Handheld Unit ........................................................................................................................ 14
6.2. WAMR NET SYSTEM .......................................................................................................... 14
Parameter setting ................................................................................................................................ 15
7.1. Brief Introduction of parameter setting software.................................................................... 15
7.2. Relative Terminology Explanation of Parameter Setting ....................................................... 15
Certificates ......................................................................................................................................... 15
8.1. Pass CE、ROHS、R&TTE Certificates ................................................................................ 16
8.2. Conform to the IP68 Standard. ............................................................................................... 16
Trouble Shooting ................................................................................................................................ 16
9.1. Common Malfunction ............................................................................................................ 16
9.2.
Installation Reference ............................................................................................................. 17
2 / 17
ShangHai Sunray Technology Co.,Ltd
1. Product Overview
SRWF-8009 is a Wireless Remote Cold Water Meter Module which passed RoHS
and meets CE certification, and supports two-way communication. It can remotely turn
on/off the valve via background management system. The Background management
system can read the meter maximally every 1.5S. Standby current is less than 30uA
when no interference. ER18505M battery (3.3A/h) will guarantee 11 years of working
time.
The modules would take on Anti-rust action for the Meter valve every 10 days to
prevent valve stuck during remote valve controlling. Conforming to the IP68 standard
test, the modules ensure well function even in humid environment.
Wireless Remote Water Meter Module can be compatible with Reed switch
metering sensor, Pairs measured at the Hall element sensor, Hall element metering
sensor, Photoelectric direct reading measurement sensor.
2. Electric Characteristics and Parameter
No.
Description
Parameter
Unit
Min
Typical
Max
Notes
Power type lithium
Power supply
3.2
3.6
4.0
thionyl chloride
battery
3 / 17
Working
current
Reading
interval
Working
temperature
Transmit
Frequency
Reliable
uA
110
120
1.5
25
65
℃
-25
MHz
470
200
250
Open field
ShangHai Sunray Technology Co.,Ltd
Transmitting
Distance
Modulation
FSK
mode
Channel
Lifetime
User can’t set the
year
channel
10
Driving
10
current of
mA
100
250
2.02
valve
Reed switch
11
module pin
pull-up
KΩ
1.98
resistors
Hall
12
component pin
input
MΩ
60
impedance
Photoelectric
13
direct reading
module output
3.2
3.6
voltage
Photoelectric
14
direct reading
module output
mA
100
current
UART Port
15
compatibility
level
4 / 17
Photoelectric meter
power supply
ShangHai Sunray Technology Co.,Ltd
3. Software Function
3.1. Measurement
3.1.1. Double Reed Switch
3.1.1.1
Reed switch module pin connection
NO
3.1.1.2
Wire Colour
Black
Purple
Green
Pin Function
Common Ground
Reed switch B
Reed switch A
A、B Reed switch pulse input timing diagram
A Reed switch
B Reed switch
t1
NO
t2
t3
Input low pulse time requirement
State
t1
t2
t3
A Closing Time
AB opening Time
B Closing Time
Min
1.5S
1S
1.5S
Typ
Max
3.1.2. Double Hall Component
3.1.2.1
5 / 17
Hall module pin connection
NO
Wire
Color
Pin Function
Pink
Hall power supply
terminal
Black
Common Ground
Test
Frequency
Max
driving
current
Power
supply
frequency
Output
level
1.5mA
(Vcc0.25)
10Hz
3V
Input
level
ShangHai Sunray Technology Co.,Ltd
3.1.2.2
Green
Purple
Hall Input B
Hall Input A
10Hz
10Hz
CMOS
CMOS
Parameter Requirements of Hall Component
VDD
Hall A
t1 t2
Hall B
t3
NO
t4
t5
Input low pulse time
requirement
State
Min
Typ
Max
t1
Hall meter head power supply
time
16mS
t2
t3、t5
t4
Detection interval
Hall low time
Two Hall high time
100mS
1.5S
1S
3.1.3. Three Hall Element
3.1.3.1
Double hall module pin connection
6 / 17
Test
Frequency
Maximal
driving
Current
Power
supply
frequency
Output
level
1.5mA(VCC0.25)
10Hz
3V
Wire
Color
Pin
Function
Pink
Hall
power
supply
terminal
Black
Common
Ground
Purple
Hall Input
10Hz
CMOS
Green
Hall Input
10Hz
CMOS
NO
Input
level
ShangHai Sunray Technology Co.,Ltd
Hall Input
White
10Hz
CMOS
3.1.1.4 Parameter of Hall Elements
VDD
Hall A
t1
t2
Hall C
Hall B
t3
NO
t4
t5
t6
t7
t8
Input low求
pulse time
Min Typ Max
16mS
100m
1.5S
1.5S
1.5S
State
t1
t2
t3+t4
t4+t5+t6
t6+t7
Hall meter power supply time
Detection interval
Hall A Low time
Hall C Low time
Hall B Low time
t8
Hall A、B、C High time
5S
t5
Hall A Low time to Hall B Low time
2S
3.1.4. Photoelectric direct reading
3.1.4.1
7 / 17
Photoelectric meter and the module pin connection
NO
Wire Color
Red
Green/Black
Pin
Function
Maximum
driving current
Module
power
supply
terminal
Controlled
public
ground
100mA
(VSS+0.2)
Power
Supply
Frequency
Outp
ut
level
Depend on
meter
reading
frequency
3.6V
Input level
ShangHai Sunray Technology Co.,Ltd
3.1.4.2
White/Black
Receive
data
Yellow/Black
Transmit
data
3.6VCMOS
5mA
Please see item 14, 15, 16 in Electric Characteristics and Parameter for detailed
interface parameter
3.1.4.3
For question related to UART Protocol, please contact the manufacturer.
3.2 Communication Function
3.2.1. Direct Reading
3.2.1.1.
Handheld unit direct reading
3.2.1.2.
Routing
3.2.1.2.1
Handheld unit reading though 1 layer routing
3.2.1.2.2
Handheld unit reading though 2 layer routing
3.3 Valve Control Function
8 / 17
3VCMOS
ShangHai Sunray Technology Co.,Ltd
3.3.1. Wireless Valve control
3.3.1.1
Remotely open/close valve
When the modules received command of open/close valve, it first return
acknowledgment signal, then conduct valve-control action.
3.3.2. Automatically open/close valve to prevent rust
When the module is working in water meter, modules will turn on/off
valve automatically once every 10 days in order to prevent the valve to
get rusty.
3.3.3. Open/close valve during Magnetic attack
3.3.3.1. Double reed switch and double hall component meter
When two reed switch (Hall) turn off at the same time (low output),
module will report magnetic interference immediately and turn off the
valve. The module will open automatically after the magnetic attacks
disappeared for some time (depending on the setting).
3.3.3.2. Three Hall meter
When A Hall and C Hall give out the low output at the same time,
module will report magnetic interference immediately and turn off the
valve. The module will open automatically after the magnetic attacks
disappeared for some time.
3.4 Battery voltage detection function
9 / 17
ShangHai Sunray Technology Co.,Ltd
3.4.1.Power-on voltage detection
Once cold start-up, module will detect battery voltage once (load 47Ω
resisitance). Low voltage will be reported if battery voltage is below
3.15V
3.4.2. Voltage Detection while Continuous Working
The module loads the 47Ω resistance to detect the battery voltage every
48 hours, and it will report low voltage when battery voltage is below
3.15V. At the same time, voltage data is updated
3.5
Alarm function
3.5.1. Low voltage Alarm
“Low voltage mark” will be set once battery voltage is below 3.15V,
while system will not actively upload the alarm information.
3.5.2. Alarm during magnetic attack
When magnetic attack detection function of module is enabled, it will
report magnetic interference during magnetic attach. The alarm
information and also upload alarm information according to uploading
enable status
3.5.3. Anti disassembling alarm
When detecting function for disassembling is enabled, it will report
“disassembling” during magnetic attach (detected continuous changes
from four direction of sensor), and it will also upload alarm information
according to uploading enable status
3.5.4. Valve failure alarm
When driver’s opening in place and closing in place are detected at the
same time before valve control or after valve control, module will report
failure in place and will not actively upload alarm information,
10 / 17
ShangHai Sunray Technology Co.,Ltd
4 Brief Introduction of Compatibility
4.1. Pulse Closing Time Requirements
See relevant introduction in software functions for details.
4.2. Pulse Number Requirements
Modules support,three pulse modes.
1 pulse for 1 cubic meter,
10 pulse for 1 cubic meter,
100
pulse for 1 cubic meter.
4.3. Valve Requirements
4.3.1. Valve control driver connection mode
Wire
Color
Module & Pin
Function
Yellow
Positive pole
during opening
valve
Red
/Blackla
ck
Negative pole
during opening
valve
Gray
Opening in place
Brown
Closing in place
Blue
NO
Valve
Type
Photoele
ctric
position
valve
Mechani
cal
position
valve
11 / 17
Controllable
ground
Red
Yellow
3.6V power output
Positive pole
during opening
valve
Red
/Black
lack
Negative pole
during opening
valve
Relative feature
Signal Type
Maximal driving
Current 250mA
Input Resistance
60MΩ
TTL
Input Resistance
60MΩ
100mA(VSS+0.25
TTL
Maximum Driving
Current 250mA
ShangHai Sunray Technology Co.,Ltd
Gray
Opening in place
3V Pull up 2K
Resistance
switch value
Closing in place
3V Pull up 2K
Resistance
switch value
Brown
Black
No
position
signal
valve
Common Ground
Yellow
Red
/Black
Positive pole
during opening
valve
Negative pole
during opening
valve
Maximum Driving
Current 250mA
4.3.2. Valve control circuit parameters
NO
Input low pulse time requirements
Status
Min
Valve control time
Valve control current
Current when valve stuck
Typ
unit:S
Max
24
unit:mA
unit:mA
250
250
1.5S
4.3.3. Supported valve type
NO
12 / 17
Type of valve in place
Valve Type
Closing valve when
Over current
Valve Type
Support
Mode
Support
Photoelectric in place
Photoelectric in place
Yes
No
Support
Support
Mechanic in place
Mechanic in place
Yes
No
None in position
None in position
Photoelectric in place
Yes
No
Yes
Support
Support
Support
10
11
Photoelectric in place
Mechanic in place
Mechanic in place
No
Yes
No
Support
Support
Support
12
13
14
None in position
None in position
None in position
Yes
No
Yes
Ball valve
Pilot valve
Electromag
Support
Support
Support
Support
Support
ShangHai Sunray Technology Co.,Ltd
15
None in position
5 Structure and Installation Size
5.1. Structure of the Module
5.2. Installation Size of the Module
13 / 17
No
netic valve
Support
ShangHai Sunray Technology Co.,Ltd
6. Communication Tools
6.1 . Handheld Unit
See “TP1100 User manual” for details
6.2. WAMR NET SYSTEM
See “WAMR NET SYSTEM User manual” for details
14 / 17
ShangHai Sunray Technology Co.,Ltd
7. Parameter setting
7.1. Brief Introduction of parameter setting software
See “WAMR NET SYSTEM User manual” for details
7.2. Relative Terminology Explanation of Parameter Setting
7.2.1.
Meter ID:Set the meter ID,Maximum 10 BCD Code,e.g.1205130001
12
05
13
0001
Batch production,number of the day
Date,13 shows if it’s manufactured on 13th
Month,05 shows if it’s manufactured in May
Year,12 shows if it’s manufactured in 2012
7.2.2.
Pulse number: corresponding pulse number for 1 m ³ water , can choose
among 1, 10, 100
7.2.3.
Magnetic interference time: Valve will be opened after the set “magnetic
interference time”, the magnetic interference time is calculated when the
magnetic interference disappeared, the unit is: second. Set range: 0-127 S
default value is: 50 S
7.2.4.
Usage: set the initial value of modules, namely, electronic number is the
same with what mechanical dial shows.
7.2.5.
Valve control time: set the 100 milliseconds as base for the action time,
such as set 4S as the action time of valve for water meter module, a table
should be filled in 20 (range: 0-127). The actual action time of valve is 2
S*2 = 4 S, the maximum valve control time can be set as 25.4 S..
7.2.6.
Meter type: Choose a meter type according to the application of module,
this module is only applicable to water meter.
7.2.7.
Pulse type: Choose according to meter.type
7.2.8.
Threshold current: mA is the unit. Parameters data is the result that the
actual value is devided by 2. For example, set threshold value as 120 mA,
60 shall be filled in, its range: 0-127, maximal threshold current that can be
set is 254 mA
8. Certificates
15 / 17
ShangHai Sunray Technology Co.,Ltd
8.1. Pass CE、ROHS、R&TTE Certificates
8.2. Conform to the IP68 Standard.
9. Trouble Shooting
9.1. Common Malfunction
NO
Problem
Solution
Notes
Check whether the ID of the meter is
Unable to read the meter
same to the one on label
Check whether the ID of the meter is
Or if there is ID
input correctly
setting of the meter
Check whether the cable of motor is
conversely connected
Unable to open/close the
Common ground of in-position line is
valve
open or not(apply for photoelectric
valve)
Check whether the motor is stuck
Check whether there is in-position line
Can’t close the valve after
positioned(Large current
consumption)
on valve
Check whether the in-position line is
reversely connected or not
Check if the set threshold current exceed
the range
Valve control not consistent
Motor cable is reversely connected
with command
Unable to measure
Check whether the measure sensor type
is correct
Check whether module pulse number is
Electrical and mechanical
consistent with the meter’s
inconsistencies
Check whether the measure sensor of
meter failed
Check whether the antenna of the module
Low reading rate
is abnormal
Low battery
Low battery
battery type is correct
Abnormal Battery Pressure
Return to manufacturer
16 / 17
Check whether the
ShangHai Sunray Technology Co.,Ltd
9.2. Installation Reference
A. The normal installation
(module antenna up and
parallel), maximize the
communication distance of
the module
B. Abnormal Installation,not
good for the communication
of the modules(shortens the
communication distance).
C. Abnormal Installation,not
good for the communication
of the modules, shortens the
communication distance.
17 / 17
ShangHai Sunray Technology Co.,Ltd
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:(1)This device may not canse harmful interference, and
(2)this device must accept any interference received,including interference that
may cause undesired operation.
Caution: The user is cautioned that changes or modifications not expressly
approved by the party responsible for compliance could void the user's authority
to operate the equipment.
15 / 15

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 18
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:88ae586f-8564-4952-964f-c3e6867c1f28
Producer                        : Acrobat Distiller 6.0 (Windows)
Modify Date                     : 2013:01:21 16:42:57+08:00
Create Date                     : 2013:01:21 16:41:04+08:00
Metadata Date                   : 2013:01:21 16:42:57+08:00
Document ID                     : uuid:96c8fcb2-c86a-473c-ad89-7e6273133bdc
Format                          : application/pdf
Title                           : untitled
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RBC-8009

Navigation menu