Superior Electronics R100TLQ Room Monitor Transmitter User Manual MI RM R100 xxxQ 181119x

Superior Electronics Corporation Room Monitor Transmitter MI RM R100 xxxQ 181119x

User manual

Download: Superior Electronics R100TLQ Room Monitor Transmitter User Manual MI RM R100 xxxQ 181119x
Mirror Download [FCC.gov]Superior Electronics R100TLQ Room Monitor Transmitter User Manual MI RM R100 xxxQ 181119x
Document ID4132274
Application ID0suEAFel3tvjccQYnOTQZw==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize30.18kB (377304 bits)
Date Submitted2019-01-19 00:00:00
Date Available2019-01-19 00:00:00
Creation Date2018-11-20 11:58:58
Producing SoftwareMicrosoft: Print To PDF
Document Lastmod2018-11-20 11:58:58
Document TitleMicrosoft Word - MI_RM-R100-xxxQ_181119.docx
Document Author: csung

ENFORCER Room Monitor
Using a Magnetic Contact for Door Monitoring:


Door monitoring should only be used for
applications where the door being monitored
is usually kept open.
If an N.C. magnetic contact is being used to
monitor the door then a 100kΩ resistor
(not included) should be installed between
the voltage and door contact inputs.
N.O. Magnetic Contact
N.C. Magnetic Contact
SIPV+
SOPGND
DNO+
SIPV+
SOPGND
DNO+
Transmitter terminals
PIR Sensor Detection Angle:
16' (5m)
41°
8' (2.5m)
16' 8'
(5m) (2.5m)
PIR Sensor
-41°
Side view
Sample Application
FCC COMPLIANCE STATEMENT
Manual
The transmitter's PIR sensor can detect movement up to
~16ft (5m). However, be sure to take into account the
height and angle at which the transmitter is mounted.
Refer to the diagrams to the right to help you decide the
best height, and orientation, to mount your Room Monitor
transmitter.
The Room Monitor can be used in a variety of
situations to monitor room occupancy, or even
assist customers if used with a service button.
Receivers can also be paired with handheld
transmitters to reset the receivers after the
service button has been pushed, or to reset any
preset timers.
Room Monitor
100kΩ
-47°
47°
Top view
RM-R100-TLQ
RM-R100-RB1Q
1 2
Room 1 occupied
1 2
RM-R100-R2Q
RM-R100-TBQ
Room 2 empty
FCC ID: K4ER100TLQ
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Notice: The changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the
device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure
requirements and void user’s authority to operate the device.
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if
damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment
is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of
SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s
option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property
damage of any kind to the purchaser or anyone else.
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM
reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks
are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2018 SECO-LARM U.S.A., Inc. All
rights reserved.
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Phone: (949) 261-2999 | (800) 662-0800
Website: www.seco-larm.com
Email: sales@seco-larm.com
PITSW1
Order Part# 763-189%
MI_RM-R100-xxxQ_181119.docx
SECO-LARM U.S.A., Inc.
Features:
 PIR Sensor detects motion
(programmable ON/OFF via jumper)
 Phototransistor detects light
(programmable ON/OFF via jumper)
 Door sensor input on transmitter for
door monitoring
 Can be programmed to flash and/or sound*
after a set amount of time
 Service button connections available**
*Buzzer available on RM-R100-RB1Q only.
**RM-R100-TLQ and RM-R100-RB1Q only.
®
 Suitable to use in restrooms, fitting rooms,
etc. to monitor occupancy
 Receiver can be paired with 15
Transmitters per channel
 Transmitter can transmit to unlimited
number of receivers
 Compatible with all ENFORCER
433.92MHz transmitters
ENFORCER Room Monitor
ENFORCER Room Monitor
Introduction:
Installation Notes:
The ENFORCER Room Monitor can be used to monitor the occupancy status of rooms in high traffic areas: restrooms,
fitting rooms, etc. The Room Monitor uses PIR and phototransistor sensors to monitor the occupancy of a room. The
single-room receiver includes additional features, such as a built-in buzzer and service button input, for applications where
occupants may need assistance. Two-room receivers are ideal for monitoring multiple rooms at once.
1. Mount the transmitter and receiver units in locations where they are not exposed to weather or moisture, and where
they are not surrounded by metal. Metal will block the RF signal, resulting in reduced range.
2. For best results, mount the transmitter and receiver units with no more than one wall in between the two.
3. If using USB power, make sure to replace the cover before connecting to the mini USB port.
4. The door contact input should only be used for applications where the door being monitored is usually kept open.
5. If an N.C. magnetic contact is being used to monitor the door then a 100kΩ resistor (not included) should be installed
between the voltage and door contact inputs. See pg. 4, Using a Magnetic Contact for Door Monitoring, for more details.
Parts List for Room Monitor Kit (RM-R100-KB1Q):
1x RM-R100-TLQ
1x Receiver decal
1x RM-R100-RB1Q
1x Manual
2x USB Power cords*
Installation:
*The RM-R100-RB1Q, RM-R100-R2Q, and RM-R100-RLQ come with 1x USB power cord.
Specifications:
Model
Description
Indicators
Memory capacity
Current
Standby
draw
Active
Transistor ground rating
PIR Sensor range
Phototransistor sensitivity
Door input
RF Range*
Operating frequency
Operating voltage
Connections
Operating temperature
Dimensions
Weight
RM-R100-TLQ
Transmitter
LED
N/A
2mA@12VDC
15mA@12VDC max.
100mA max.
~16' (5m)
≥320Lux
NO or NC
RM-R100-RB1Q
RM-R100-R2Q
Single-room, 1-ch receiver
Two-room, 2-ch receiver
Buzzer and LED
LED
15 Transmitter codes, per channel
6mA@12VDC
35mA@12VDC max
N/A
N/A
N/A
N/A
100' (30m)
433.92MHz
5VDC via micro USB or 5~12 VDC via terminals
Screw terminals
-4°~167° F (-20°~75° C)
21/2"x15/16"x17/8" (64x24x48 mm)
1.8-oz (50g)
*Actual operating range will vary greatly depending on the installation and operating environment.
Overview:
Transmitter
Phototransistor ON/OFF jumper
Phototransistor
PIR Sensor
PIR ON/OFF jumper
Wire pass-through
Receiver
Buzzer
(1-Ch receiver only)
Antenna
Pairing button
LED ON/OFF jumper
LED Indicator
Micro USB Power
input
Service input, N.O. (SIP-)
V+
Service output (SOP-)
GND
Door sensor input (DNO+)
Buzzer ON/OFF jumper (1-Ch receiver only)
Service/Ch2 pairing button
Ch1 Pairing button
V+
LED Indicators*
GND
Micro USB power
Service input, N.O. (SIP)
input
(1-Ch receiver only)
Wire pass-through
Fig. 1
Wire
pass-through
Fig. 2
Slide
down
Mounting holes
Setting Reminder Time:
NOTE: Pairing button must be pressed within 5 seconds of powering on the transmitter/receiver.
1. Power on receiver/transmitter unit.
2. Press pairing button and count number of times LED flashes
3. Repeat step 2 until desired reminder time is set. See table below for reminder time settings.
# of Flashes
Reminder time
Disabled
3min
5min
10min
15min
20min
30min
Code Learning a New Transmitter:
Each receiver channel can learn the codes of up to 15 different transmitters on a first-in, first-out basis. The procedure for
code learning a new transmitter is as follows:
1. Once the receiver has been powered on for over 5 seconds, press the pairing button of the desired channel for
3 seconds or more. The channel's LED will start to flash quickly to indicate that it is in learning mode.
2. While the LED is flashing, press the button of the transmitter to be learned one time. The receiver's channel indicator
LED will flash once to indicate the transmitter has been successfully learned. After the transmitter has been learned,
the receiver will automatically exit learning mode. To learn further codes, repeat step 1 to re-enter learning mode.
NOTES:
 The channel's indicator LED will flash a maximum of 30 seconds. If no transmitter button is pressed during this time,
the receiver will automatically exit learning mode, and the LED will turn off.
 If the code being learned has already been learned, the channel indicator LED will turn steady ON and then start
flashing again. The code will not be learned a second time.
 One channel can learn the codes of a maximum of 15 transmitter buttons. If you attempt to learn a sixteenth
transmitter code, the earliest code learned will be deleted and the new code will be learned.
Clear Channel Memory:
To clear all codes from a channel’s memory, press the channel pairing button for 3 seconds or more until the channel
indicator LED begins flashing. Release, and then press the button again for 3 seconds or more until the LED stops flashing.
The LED will then flash twice to indicate that all codes associated with that channel have been deleted.
Display Channel Memory:
To see how many codes have been learned by a channel, press that channel’s pairing button once. The number of codes
stored in the channel’s memory corresponds with the number of times the channel's LED indicators flash.
*2-Ch receiver has 4 LED indicators (2 for each channel).
1. Find a suitable location to mount the transmitter/receiver.
2. Remove the top cover and PCB. Place the bottom case on the wall where
it is to be mounted, and mark the wall through the two mounting holes.
3. Screw two mounting screw (not included) into the marked locations, and
slide the bottom case down onto the screws (see Fig. 2).
4. Tighten the screws as needed, but take care not to overtighten and ensure
the case can still be removed by sliding.
NOTE: Mark the location of the wire pass-through hole now, if needed.
5. Remove the bottom case from the wall and feed wires through the wire
pass-through holes (PCB and case) and wire as necessary.
6. Replace the top cover and slide back onto mounting screws.
SECO-LARM U.S.A., Inc.
SECO-LARM U.S.A., Inc.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Warning                         : Info object (62 0 obj) not found at 375758
EXIF Metadata provided by EXIF.tools
FCC ID Filing: K4ER100TLQ

Navigation menu