Suprema BEWIOC BioEntry W User Manual

Suprema Inc. BioEntry W

User manual

Download: Suprema BEWIOC BioEntry W User Manual
Mirror Download [FCC.gov]Suprema BEWIOC BioEntry W User Manual
Document ID1924582
Application IDBbWGN+Ye9x9E0xZdjkzpsA==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize291.03kB (3637885 bits)
Date Submitted2013-03-25 00:00:00
Date Available2013-03-25 00:00:00
Creation Date2013-03-12 11:45:39
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2013-03-12 11:45:39
Document Title(Microsoft PowerPoint - \(BEWI\)BioEntry W_InstallationGuide_V0.1_EN_130312.ppt [\310\243\310\257 \270\360\265\345])
Document CreatorPScript5.dll Version 5.2.2
Document Author: hjlim

BioEntry W
Compact Outdoor Fingerprint Reader/Controller
Installation Guide
Version V1.0
www.supremainc.com
BioEntry W
Important Safety Information
Carefully review the information within the user manual before installing/operating the device.
Pay careful attention to the warning and cautions below as they are here to prevent any risk/damage to
any person(s) or property associated with the device.
Warning
Failure to heed these warnings may lead to serious
injury or even death!
Installation
 Do not install the device near heat sources such as radiators,
heat registers, and stoves.
 Do not install the device near areas of large electromagnetic
interference.
Usage
 Do not disassemble, repair or reconstruct the device.
Contact your nearest Suprema dealer for technical support.
 Only use the device its intended use.
Caution
Failure to heed these cautions may lead to minor injury
or damage the device.
Installation
 Do not leave cables (especially power cables) exposed to
the outer environment.
 Do not install the device near objects with a strong magnetic
field such as magnets, computer monitors (especially CRT),
TV screens and speakers.
Usage
 Do not drop or apply any physical shock/impact to the device.
 Regularly clean the product with a soft dry cloth; avoid
benzene or alcohol.
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Contents
About Fingerprint Recognition
How to Enroll a Fingerprint on the Device
Components
Product Description
Dimensions
11
Cable Specifications
12
Installation
13
System Configurations
14
Connections
17
Resetting Network Settings
28
Electrical Specifications
29
Product Specifications
30
Troubleshooting
31
Precautions for Device cleaning
32
FCC Rules
33
ⒸCopyright 2007 Suprema Inc.
BioEntry W
About Fingerprint Recognition
What is a fingerprint?
Fingerprints are individual’s own biometric information and do not change throughout one’s life. Fingerprint
recognition is a technology that verifies or identifies an individual using such fingerprint information. Free from
the risk of theft or loss, fingerprint recognition technology is being widely used in security systems replacing
PIN or cards.
What is fingerprint recognition?
Fingerprints consist of ridges and valleys. Ridge is a flow of protruding skin in a fingerprint while valley is the
hollow between two ridges. Each individual has unique patterns of ridges and valleys; fingerprint recognition
makes use of these differences to differentiate between individuals.
Fingerprint sensors generate 2-dimentional fingerprint images using various technologies: optical, capacitive, or
thermal. Fingerprint template is a collection of numeric data representing the features of a fingerprint.
Fingerprint templates are saved inside the memory of BioEntry W, and used for identification.
Suprema’s Personal Information Protection Technology
To avoid privacy concern, Suprema’s fingerprint products do not save fingerprint images itself. It is impossible
to reconstruct a fingerprint image from a fingerprint template which is just numeric data of the features of a
fingerprint.
ⒸCopyright 2007 Suprema Inc.
BioEntry W
How to Enroll a Fingerprint on the Device
Suprema's fingerprint products have outstanding recognition performance regardless of the user's fingerprint
condition or positioning. However pay careful attention to the following instructions to maximize the performance
of the device.
Fingerprint Enrollment
It is recommended to enroll the index or middle finger.
The thumb, ring or little finger are generally more difficult to position properly.
How to place a finger on a sensor
Fully cover or provide maximum contact to the surface of the sensor with the desired finger. People tend to
place the tip of a finger on the sensor; this will only provide a small area of the finger to be captured and will
result in poor performance.
Place the core of the fingerprint near the center of the sensor. This will ensure a good template will be
created. The core of a fingerprint is a center where the spiral of ridges is most dense.
ⒸCopyright 2007 Suprema Inc.
BioEntry W
How to Enroll a Fingerprint on the Device
Fingerprint Enrollment Precautions
Operational Warnings
 If a finger is wet or too moist, wipe off the moisture then try the scan again.
 If a finger is covered with dust or impurities, clean the finger then try the scan again.
 If a finger is dry, breathe warm air onto the finger then try the scan again.
Solving Authentication Difficulties
 Delete then Re-enroll the finger.
 Enroll the same finger multiple times.
 Try a different finger with a more vivid fingerprint.
 Enroll various fingers for each user.
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Components
Basic Components
Wall Mount Screws (2)
Wall Mounting bracket (1)
Main Unit Mounting
Screws (2)
Software CD (1)
BioEntry W
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Components
Optional Accessories
Secure I/O
12VDC Power Adaptor
Plastic Stand
USB Fingerprint
Scanner
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Product Description
Front
LED
Displays the current status with
various colors.
RFID Scanner
Place an RFID card over the
scanner.
Fingerprint Sensor
Place a finger on the surface of the
sensor.
LED
Green
Device Status
Successful Authentication
Red
Failed Authentication
Pink
Processing
Flicker Blue/Sky-Blue
Color per 2sec
Standard Operation
Flicker Red/Pink
Color per 2sec
Device Locked
Flicker Blue/Red
Color per 2sec
Discharged Internal Battery
Flicker Blue/Yellow
Color per 2sec
Flicker Red Color per
2sec
Unable to Acquire an IP
Address from the DHCP
Server.
Unit Malfunction. Contact Your
Suprema Dealer/Distributor.
Flicker Yellow Color
per 2sec
Waiting for an Input
Flicker Yellow Color
per 1sec
Requesting IP Address from
the DHCP Server.
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Product Description
Rear and Bottom
Cables
Wiegand Input/Output Cables
Power Cables
RS485 Cables
Ethernet Connector
Input Cables
Relay Cables
LED
Network Status LED
Network Reset Switch
See "Resetting Network Settings (page 28)" for more details.
Star-shaped screw hole for fixing a body to a metal bracket
ⒸCopyright 2007 Suprema Inc.
10
BioEntry W
Dimensions
BioEntry W
44 mm
172 mm
50 mm
Wall Mounting Bracket
40 mm
172 mm
157 mm
ⒸCopyright 2007 Suprema Inc.
11
BioEntry W
Cable Specifications
PIN
Description
Color
SWIN1
BROWN
SWIN0
PURPLE
ETH TXP
WHITE
ETH TXN
ORANGE
ETH RXP
BLACK
ETH RXN
YELLOW
POWER IN
RED
POWER GND
BLACK
PoE VB2
BLUE
PoE VB2
BROWN
PoE VB1
RED
PoE VB1
GREEN
11
485 TRXN
YELLOW/WHITE STRIPE
12
485 TRXP
BLUE/WHITE STRIPE
13
485 GND
BLACK/WHITE STRIPE
14
WIEGAND GND
WHITE/BLACK STRIPE
15
WIEGAND D1
WHITE
16
WIEGAND D0
GREEN
17
NC
PINK
18
RELAY NC
ORANGE/WHITE STRIPE
19
RELAY COM
GREEN/WHITE STRIPE
20
RELAY NO
GRAY/WHITE STRIPE
10
ⒸCopyright 2007 Suprema Inc.
12
BioEntry W
Installation
1. Fix the wall mounting bracket on a wall by
using wall mounting screws.
3. Fix the device to the wall mounting bracket using the
star-shaped screws.
2. Hook the device on the wall mount bracket.
Star-shaped
screw
Wall
Mount
Screws
ⒸCopyright 2007 Suprema Inc.
13
BioEntry W
System Configurations
Standard
Door Sensor
Door Lock
Exit Button
BioEntry W
LAN
PC
USB Fingerprint
Scanner
ⒸCopyright 2007 Suprema Inc.
14
BioEntry W
System Configurations
Secure (Secure I/O)
RS485
Door Sensor
Door Lock
Exit Button
Secure I/O
BioEntry W
LAN
PC
USB Fingerprint
Scanner
ⒸCopyright 2007 Suprema Inc.
15
BioEntry W
System Configurations
Network
Door Zone 1 (Anti-passback)
RS485
RS485
Secure I/O
FaceStation
BioEntry W
BioEntry W
LAN
PC Server
USB Fingerprint
Scanner
PC Client
FaceStation
Secure I/O
BioEntry W
Exit Button
RS485
PC Client
Door Zone 2 (Anti-passback)
ⒸCopyright 2007 Suprema Inc.
16
BioEntry W
Connections
Power Connection
DC Power
UPS
(Optional)
Supply
DC Power
Supply
Recommended Power Specifications
− 12V ±10%, at least 500mA.
− Comply with standard IEC/EN 60950-1.
− When sharing power with other devices, use a power supply with a higher current rating.
ⒸCopyright 2007 Suprema Inc.
17
BioEntry W
Connections
Ethernet Connection (Connection with HUB)
The device can be connected with a regular hub or PoE hub by connecting the Ethernet cable to the Ethernet
terminal. PoE(Power over Ethernet) is an Ethernet connection of which the power is supplied from PSE(Power
Sourcing Equipment) satisfying the IEEE802.3af standard.
Ethernet Hub
ⒸCopyright 2007 Suprema Inc.
18
BioEntry W
Connections
Ethernet Connection (Direct connection with PC)
Use a standard CAT-5 cable to connect the device directly to a PC.
BioEntry W supports auto MDI/MDIX, therefore a crossover cable is not necessary.
ⒸCopyright 2007 Suprema Inc.
19
BioEntry W
Connections
RS485 Connection for Host Communication
Power IN (Red)
Power GND (Black)
Signal GND (Black/White Stripe)
TRX+ (Blue/White Stripe)
TRX- (Yellow/White Stripe)
GND TRX+
TRXRS232-485
Converter
BioEntry W
Power IN (Red)
Power GND (Black)
Signal GND (Black/White Stripe)
TRX+ (Blue/White Stripe)
TRX- (Yellow/White Stripe)
BioEntry W
Notes
− Only the devices at the both ends of the bus should be terminated. To enable termination on the RS232-485 converter,
−
−
refer to the converter’s manual.
Adjust the communication speed as needed. The signal quality vary depending on wiring conditions, and it may be
necessary to lower the baudrates.
The GND signal may be omitted if and only if the GND potential difference is less than 5V.
±
ⒸCopyright 2007 Suprema Inc.
20
BioEntry W
Connections
RS485 Connection for Secure I/O
Power IN (Red)
Power GND (Black)
Signal GND (Black/ White Stripe)
TRX+ (Blue/ White Stripe)
TRX- (Yellow/ White Stripe)
Power IN (Red)
Power GND (Black)
Signal GND (Black/White Stripe)
TRX+ (Blue/White Stripe)
TRX- (Yellow/White Stripe)
BioEntry W
BioEntry W
TRX GND TRX+
TRX-
TRX GND TRX+
TRX-
Secure I/O
Secure I/O
Notes
− For bus termination, only the devices at both ends of the bus should be terminated.
− Maximum numbers of devices in an RS485 loop are two(2) Suprema devices and four Secure I/Os.
ⒸCopyright 2007 Suprema Inc.
21
BioEntry W
Connections
Relay Connection – Fail safe lock
BioEntry W
(20) Relay NO (Gray/White Stripe)
(19) Relay COM (Green/White Stripe)
(18) Relay NC (Orange/White Stripe)
Deadbolt /
Door strike
DC
Power supply
ⒸCopyright 2007 Suprema Inc.
22
BioEntry W
Connections
Relay Connection – Fail secure lock
BioEntry W
(20) Relay NO (Gray/White Stripe)
(19) Relay COM (Green/White Stripe)
(18) Relay NC (Orange/White Stripe)
Deadbolt /
Door strike
DC
Power supply
ⒸCopyright 2007 Suprema Inc.
23
BioEntry W
Connections
Relay Connection - Automatic door
RTE Switch
Presence
Detector
BioEntry W
Automatic
Door
RTE Switch
(20) Relay NO (Gray/White Stripe)
(19) Relay COM (Green/White Stripe)
(18) Relay NC (Orange/White Stripe)
ⒸCopyright 2007 Suprema Inc.
24
BioEntry W
Connections
Digital Input Connection (RTE/ Door sensor)
BioEntry W
(13)
(1)
(13)
(2)
Door Status
485 GND (Black/White Stripe)
Input 1 (Brown)
485 GND (Black/White Stripe)
Input 0 (Purple)
Request TO
Exit
ⒸCopyright 2007 Suprema Inc.
25
BioEntry W
Connections
Digital Input Connection (Alarm/ Emergency switch)
BioEntry W
(13)
(1)
(13)
(2)
Switch #1
485 GND (Black/White Stripe)
Input 1 (Brown)
485 GND (Black/White Stripe)
Input 0 (Purple)
Switch #2
ⒸCopyright 2007 Suprema Inc.
26
BioEntry W
Connections
Wiegand Input
RFID Reader
GND
Wiegand D1
Wiegand D0
BioEntry W
(14) Wiegand GND (White/Black Stripe)
(15) Wiegand D1 (White)
(16) Wiegand D0 (Green)
Wiegand Output
Controller
GND
Wiegand D1
Wiegand D0
BioEntry W
(14) Wiegand GND (White/Black Stripe)
(15) Wiegand D1 (White)
(16) Wiegand D0 (Green)
ⒸCopyright 2007 Suprema Inc.
27
BioEntry W
Resetting Network Settings
In case of forgetting network setting of the device (TCP/IP or RS-485 setting) during installation or using the
device, you can initialize network setting (TCP/IP or RS-485 setting) by using the network reset switch on the
back panel of the device. Please refer to the figures as below.
1.
Turn on the device.
2.
Press and hold the network reset switch until the device
turns off. (Then, the device will restart.)
Network Default Setting
 TCP/IP Address : 192.168.0.1
 Not checked “Use Server”
 RS-485 : PC Connection, 115200bps
3.
Modify then save the TCP/IP or RS485 settings.
4.
Reboot the device.
5.
Confirm the new settings.
Network Reset
Switch
ⒸCopyright 2007 Suprema Inc.
28
BioEntry W
Electrical Specifications
Min.
Typ.
Max.
Notes
Voltage (V)
10.8
12
13.2
Current (mA)
VIH (V)
TBD
VIL (V)
TBD
Pull-up resistance (Ω)
4.7k
VOH (V)
VOL (V)
0.8
Pull-up resistance (Ω)
4.7k
Switching capacity (A)
0.3
30V DC
125V AC
Switching power
(resistive)
30W
37.5VA
DC
AC
Switching voltage (V)
110
125
DC
AC
Use regulated DC power adaptor only.
Power
Switch Input
TTL/
Wiegand Output
Relay
250
The input ports are pulled up with 4.7k resistors.
The outputs ports are open drain type, pulled up
with 4.7k resistors internally.
ⒸCopyright 2007 Suprema Inc.
29
BioEntry W
Product Specifications
Max Users
Log Capacity
CPU
5000 users (10,000 templates) [1:1 & 1:N]
50,000 logs
533MHz DSP
Memory
8MB Flash + 8MB RAM
System
RF Options
Interfaces
Input / Output
Power
General
13.56MHz iClass
TCP/IP, RS485, Wiegand
2 TTL Inputs, 1 Relay Output
12VDC, PoE (Power over Ethernet)
BioEntry W
(W x H x D)
50 x 172 x 44 mm
Wall Bracket
(W x H)
40 x 157 mm (screw joint included)
Dimensions
ⒸCopyright 2007 Suprema Inc.
30
BioEntry W
Troubleshooting
Please contact your local dealer/distributor for support or contact Suprema at support@supremainc.com.
Please submit the following information and we will coordinate support with your local dealer/distributor.
Device model
F/W version of the device
H/W version of the device
Detailed information regarding the issue
Error messages / screenshots, if possible
Contact information (Company, Name, Telephone, Email)
ⒸCopyright 2007 Suprema Inc.
31
BioEntry W
Precautions for Device Cleaning
Wipe out the device surface with dry towel or cloth.
Use a soft dry towel when removing dust or impurities from the surface of the sensor.
Cleaning the sensor with a detergent, benzene or thinner will damage the surface and disrupt the unit's
ability to properly read a fingerprint.
ⒸCopyright 2007 Suprema Inc.
32
BioEntry W
FCC Rules
Caution
Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the
user’s authority to operate the equipment.
Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interface, and (2) this device must accept any interface received, including
interference that may cause undesired operation.
Information to User
This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, user and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation; if this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more the following measures:
1.
2.
3.
4.
Reorient / Relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
ⒸCopyright 2007 Suprema Inc.
33
㈜슈프리마
경기도 성남시 분당구 정자동 파크뷰 오피스타워 16층
Tel : 031-783-4510
Fax : 031-783-4503
온라인고객지원 : sales@suprema.co.kr
회사홈페이지 : www.suprema.co.kr
제품홈페이지 : www.biostation.co.kr
의 기능 및 사양은 제품의 품질 향상이나 기능 수정 등으로 인해 예고 없이 변경될 수 있습니다.
제품에 대한 자세한 사항은 ㈜슈프리마로 문의 바랍니다.
BioEntry Plus

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 34
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2013:03:12 11:45:39
Modify Date                     : 2013:03:12 11:45:39
Title                           : (Microsoft PowerPoint - \(BEWI\)BioEntry W_InstallationGuide_V0.1_EN_130312.ppt [\310\243\310\257 \270\360\265\345])
Creator                         : PScript5.dll Version 5.2.2
Author                          : hjlim
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TKWBEWIOC

Navigation menu