User manual
BioEntry W Compact Outdoor Fingerprint Reader/Controller Installation Guide Version V1.0 www.supremainc.com BioEntry W Important Safety Information Carefully review the information within the user manual before installing/operating the device. Pay careful attention to the warning and cautions below as they are here to prevent any risk/damage to any person(s) or property associated with the device. Warning Failure to heed these warnings may lead to serious injury or even death! Installation Do not install the device near heat sources such as radiators, heat registers, and stoves. Do not install the device near areas of large electromagnetic interference. Usage Do not disassemble, repair or reconstruct the device. Contact your nearest Suprema dealer for technical support. Only use the device its intended use. Caution Failure to heed these cautions may lead to minor injury or damage the device. Installation Do not leave cables (especially power cables) exposed to the outer environment. Do not install the device near objects with a strong magnetic field such as magnets, computer monitors (especially CRT), TV screens and speakers. Usage Do not drop or apply any physical shock/impact to the device. Regularly clean the product with a soft dry cloth; avoid benzene or alcohol. ⒸCopyright 2007 Suprema Inc. BioEntry W Contents About Fingerprint Recognition How to Enroll a Fingerprint on the Device Components Product Description Dimensions 11 Cable Specifications 12 Installation 13 System Configurations 14 Connections 17 Resetting Network Settings 28 Electrical Specifications 29 Product Specifications 30 Troubleshooting 31 Precautions for Device cleaning 32 FCC Rules 33 ⒸCopyright 2007 Suprema Inc. BioEntry W About Fingerprint Recognition What is a fingerprint? Fingerprints are individual’s own biometric information and do not change throughout one’s life. Fingerprint recognition is a technology that verifies or identifies an individual using such fingerprint information. Free from the risk of theft or loss, fingerprint recognition technology is being widely used in security systems replacing PIN or cards. What is fingerprint recognition? Fingerprints consist of ridges and valleys. Ridge is a flow of protruding skin in a fingerprint while valley is the hollow between two ridges. Each individual has unique patterns of ridges and valleys; fingerprint recognition makes use of these differences to differentiate between individuals. Fingerprint sensors generate 2-dimentional fingerprint images using various technologies: optical, capacitive, or thermal. Fingerprint template is a collection of numeric data representing the features of a fingerprint. Fingerprint templates are saved inside the memory of BioEntry W, and used for identification. Suprema’s Personal Information Protection Technology To avoid privacy concern, Suprema’s fingerprint products do not save fingerprint images itself. It is impossible to reconstruct a fingerprint image from a fingerprint template which is just numeric data of the features of a fingerprint. ⒸCopyright 2007 Suprema Inc. BioEntry W How to Enroll a Fingerprint on the Device Suprema's fingerprint products have outstanding recognition performance regardless of the user's fingerprint condition or positioning. However pay careful attention to the following instructions to maximize the performance of the device. Fingerprint Enrollment It is recommended to enroll the index or middle finger. The thumb, ring or little finger are generally more difficult to position properly. How to place a finger on a sensor Fully cover or provide maximum contact to the surface of the sensor with the desired finger. People tend to place the tip of a finger on the sensor; this will only provide a small area of the finger to be captured and will result in poor performance. Place the core of the fingerprint near the center of the sensor. This will ensure a good template will be created. The core of a fingerprint is a center where the spiral of ridges is most dense. ⒸCopyright 2007 Suprema Inc. BioEntry W How to Enroll a Fingerprint on the Device Fingerprint Enrollment Precautions Operational Warnings If a finger is wet or too moist, wipe off the moisture then try the scan again. If a finger is covered with dust or impurities, clean the finger then try the scan again. If a finger is dry, breathe warm air onto the finger then try the scan again. Solving Authentication Difficulties Delete then Re-enroll the finger. Enroll the same finger multiple times. Try a different finger with a more vivid fingerprint. Enroll various fingers for each user. ⒸCopyright 2007 Suprema Inc. BioEntry W Components Basic Components Wall Mount Screws (2) Wall Mounting bracket (1) Main Unit Mounting Screws (2) Software CD (1) BioEntry W ⒸCopyright 2007 Suprema Inc. BioEntry W Components Optional Accessories Secure I/O 12VDC Power Adaptor Plastic Stand USB Fingerprint Scanner ⒸCopyright 2007 Suprema Inc. BioEntry W Product Description Front LED Displays the current status with various colors. RFID Scanner Place an RFID card over the scanner. Fingerprint Sensor Place a finger on the surface of the sensor. LED Green Device Status Successful Authentication Red Failed Authentication Pink Processing Flicker Blue/Sky-Blue Color per 2sec Standard Operation Flicker Red/Pink Color per 2sec Device Locked Flicker Blue/Red Color per 2sec Discharged Internal Battery Flicker Blue/Yellow Color per 2sec Flicker Red Color per 2sec Unable to Acquire an IP Address from the DHCP Server. Unit Malfunction. Contact Your Suprema Dealer/Distributor. Flicker Yellow Color per 2sec Waiting for an Input Flicker Yellow Color per 1sec Requesting IP Address from the DHCP Server. ⒸCopyright 2007 Suprema Inc. BioEntry W Product Description Rear and Bottom Cables Wiegand Input/Output Cables Power Cables RS485 Cables Ethernet Connector Input Cables Relay Cables LED Network Status LED Network Reset Switch See "Resetting Network Settings (page 28)" for more details. Star-shaped screw hole for fixing a body to a metal bracket ⒸCopyright 2007 Suprema Inc. 10 BioEntry W Dimensions BioEntry W 44 mm 172 mm 50 mm Wall Mounting Bracket 40 mm 172 mm 157 mm ⒸCopyright 2007 Suprema Inc. 11 BioEntry W Cable Specifications PIN Description Color SWIN1 BROWN SWIN0 PURPLE ETH TXP WHITE ETH TXN ORANGE ETH RXP BLACK ETH RXN YELLOW POWER IN RED POWER GND BLACK PoE VB2 BLUE PoE VB2 BROWN PoE VB1 RED PoE VB1 GREEN 11 485 TRXN YELLOW/WHITE STRIPE 12 485 TRXP BLUE/WHITE STRIPE 13 485 GND BLACK/WHITE STRIPE 14 WIEGAND GND WHITE/BLACK STRIPE 15 WIEGAND D1 WHITE 16 WIEGAND D0 GREEN 17 NC PINK 18 RELAY NC ORANGE/WHITE STRIPE 19 RELAY COM GREEN/WHITE STRIPE 20 RELAY NO GRAY/WHITE STRIPE 10 ⒸCopyright 2007 Suprema Inc. 12 BioEntry W Installation 1. Fix the wall mounting bracket on a wall by using wall mounting screws. 3. Fix the device to the wall mounting bracket using the star-shaped screws. 2. Hook the device on the wall mount bracket. Star-shaped screw Wall Mount Screws ⒸCopyright 2007 Suprema Inc. 13 BioEntry W System Configurations Standard Door Sensor Door Lock Exit Button BioEntry W LAN PC USB Fingerprint Scanner ⒸCopyright 2007 Suprema Inc. 14 BioEntry W System Configurations Secure (Secure I/O) RS485 Door Sensor Door Lock Exit Button Secure I/O BioEntry W LAN PC USB Fingerprint Scanner ⒸCopyright 2007 Suprema Inc. 15 BioEntry W System Configurations Network Door Zone 1 (Anti-passback) RS485 RS485 Secure I/O FaceStation BioEntry W BioEntry W LAN PC Server USB Fingerprint Scanner PC Client FaceStation Secure I/O BioEntry W Exit Button RS485 PC Client Door Zone 2 (Anti-passback) ⒸCopyright 2007 Suprema Inc. 16 BioEntry W Connections Power Connection DC Power UPS (Optional) Supply DC Power Supply Recommended Power Specifications − 12V ±10%, at least 500mA. − Comply with standard IEC/EN 60950-1. − When sharing power with other devices, use a power supply with a higher current rating. ⒸCopyright 2007 Suprema Inc. 17 BioEntry W Connections Ethernet Connection (Connection with HUB) The device can be connected with a regular hub or PoE hub by connecting the Ethernet cable to the Ethernet terminal. PoE(Power over Ethernet) is an Ethernet connection of which the power is supplied from PSE(Power Sourcing Equipment) satisfying the IEEE802.3af standard. Ethernet Hub ⒸCopyright 2007 Suprema Inc. 18 BioEntry W Connections Ethernet Connection (Direct connection with PC) Use a standard CAT-5 cable to connect the device directly to a PC. BioEntry W supports auto MDI/MDIX, therefore a crossover cable is not necessary. ⒸCopyright 2007 Suprema Inc. 19 BioEntry W Connections RS485 Connection for Host Communication Power IN (Red) Power GND (Black) Signal GND (Black/White Stripe) TRX+ (Blue/White Stripe) TRX- (Yellow/White Stripe) GND TRX+ TRXRS232-485 Converter BioEntry W Power IN (Red) Power GND (Black) Signal GND (Black/White Stripe) TRX+ (Blue/White Stripe) TRX- (Yellow/White Stripe) BioEntry W Notes − Only the devices at the both ends of the bus should be terminated. To enable termination on the RS232-485 converter, − − refer to the converter’s manual. Adjust the communication speed as needed. The signal quality vary depending on wiring conditions, and it may be necessary to lower the baudrates. The GND signal may be omitted if and only if the GND potential difference is less than 5V. ± ⒸCopyright 2007 Suprema Inc. 20 BioEntry W Connections RS485 Connection for Secure I/O Power IN (Red) Power GND (Black) Signal GND (Black/ White Stripe) TRX+ (Blue/ White Stripe) TRX- (Yellow/ White Stripe) Power IN (Red) Power GND (Black) Signal GND (Black/White Stripe) TRX+ (Blue/White Stripe) TRX- (Yellow/White Stripe) BioEntry W BioEntry W TRX GND TRX+ TRX- TRX GND TRX+ TRX- Secure I/O Secure I/O Notes − For bus termination, only the devices at both ends of the bus should be terminated. − Maximum numbers of devices in an RS485 loop are two(2) Suprema devices and four Secure I/Os. ⒸCopyright 2007 Suprema Inc. 21 BioEntry W Connections Relay Connection – Fail safe lock BioEntry W (20) Relay NO (Gray/White Stripe) (19) Relay COM (Green/White Stripe) (18) Relay NC (Orange/White Stripe) Deadbolt / Door strike DC Power supply ⒸCopyright 2007 Suprema Inc. 22 BioEntry W Connections Relay Connection – Fail secure lock BioEntry W (20) Relay NO (Gray/White Stripe) (19) Relay COM (Green/White Stripe) (18) Relay NC (Orange/White Stripe) Deadbolt / Door strike DC Power supply ⒸCopyright 2007 Suprema Inc. 23 BioEntry W Connections Relay Connection - Automatic door RTE Switch Presence Detector BioEntry W Automatic Door RTE Switch (20) Relay NO (Gray/White Stripe) (19) Relay COM (Green/White Stripe) (18) Relay NC (Orange/White Stripe) ⒸCopyright 2007 Suprema Inc. 24 BioEntry W Connections Digital Input Connection (RTE/ Door sensor) BioEntry W (13) (1) (13) (2) Door Status 485 GND (Black/White Stripe) Input 1 (Brown) 485 GND (Black/White Stripe) Input 0 (Purple) Request TO Exit ⒸCopyright 2007 Suprema Inc. 25 BioEntry W Connections Digital Input Connection (Alarm/ Emergency switch) BioEntry W (13) (1) (13) (2) Switch #1 485 GND (Black/White Stripe) Input 1 (Brown) 485 GND (Black/White Stripe) Input 0 (Purple) Switch #2 ⒸCopyright 2007 Suprema Inc. 26 BioEntry W Connections Wiegand Input RFID Reader GND Wiegand D1 Wiegand D0 BioEntry W (14) Wiegand GND (White/Black Stripe) (15) Wiegand D1 (White) (16) Wiegand D0 (Green) Wiegand Output Controller GND Wiegand D1 Wiegand D0 BioEntry W (14) Wiegand GND (White/Black Stripe) (15) Wiegand D1 (White) (16) Wiegand D0 (Green) ⒸCopyright 2007 Suprema Inc. 27 BioEntry W Resetting Network Settings In case of forgetting network setting of the device (TCP/IP or RS-485 setting) during installation or using the device, you can initialize network setting (TCP/IP or RS-485 setting) by using the network reset switch on the back panel of the device. Please refer to the figures as below. 1. Turn on the device. 2. Press and hold the network reset switch until the device turns off. (Then, the device will restart.) Network Default Setting TCP/IP Address : 192.168.0.1 Not checked “Use Server” RS-485 : PC Connection, 115200bps 3. Modify then save the TCP/IP or RS485 settings. 4. Reboot the device. 5. Confirm the new settings. Network Reset Switch ⒸCopyright 2007 Suprema Inc. 28 BioEntry W Electrical Specifications Min. Typ. Max. Notes Voltage (V) 10.8 12 13.2 Current (mA) VIH (V) TBD VIL (V) TBD Pull-up resistance (Ω) 4.7k VOH (V) VOL (V) 0.8 Pull-up resistance (Ω) 4.7k Switching capacity (A) 0.3 30V DC 125V AC Switching power (resistive) 30W 37.5VA DC AC Switching voltage (V) 110 125 DC AC Use regulated DC power adaptor only. Power Switch Input TTL/ Wiegand Output Relay 250 The input ports are pulled up with 4.7k resistors. The outputs ports are open drain type, pulled up with 4.7k resistors internally. ⒸCopyright 2007 Suprema Inc. 29 BioEntry W Product Specifications Max Users Log Capacity CPU 5000 users (10,000 templates) [1:1 & 1:N] 50,000 logs 533MHz DSP Memory 8MB Flash + 8MB RAM System RF Options Interfaces Input / Output Power General 13.56MHz iClass TCP/IP, RS485, Wiegand 2 TTL Inputs, 1 Relay Output 12VDC, PoE (Power over Ethernet) BioEntry W (W x H x D) 50 x 172 x 44 mm Wall Bracket (W x H) 40 x 157 mm (screw joint included) Dimensions ⒸCopyright 2007 Suprema Inc. 30 BioEntry W Troubleshooting Please contact your local dealer/distributor for support or contact Suprema at support@supremainc.com. Please submit the following information and we will coordinate support with your local dealer/distributor. Device model F/W version of the device H/W version of the device Detailed information regarding the issue Error messages / screenshots, if possible Contact information (Company, Name, Telephone, Email) ⒸCopyright 2007 Suprema Inc. 31 BioEntry W Precautions for Device Cleaning Wipe out the device surface with dry towel or cloth. Use a soft dry towel when removing dust or impurities from the surface of the sensor. Cleaning the sensor with a detergent, benzene or thinner will damage the surface and disrupt the unit's ability to properly read a fingerprint. ⒸCopyright 2007 Suprema Inc. 32 BioEntry W FCC Rules Caution Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment. Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interface, and (2) this device must accept any interface received, including interference that may cause undesired operation. Information to User This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, user and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation; if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more the following measures: 1. 2. 3. 4. Reorient / Relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. ⒸCopyright 2007 Suprema Inc. 33 ㈜슈프리마 경기도 성남시 분당구 정자동 파크뷰 오피스타워 16층 Tel : 031-783-4510 Fax : 031-783-4503 온라인고객지원 : sales@suprema.co.kr 회사홈페이지 : www.suprema.co.kr 제품홈페이지 : www.biostation.co.kr 의 기능 및 사양은 제품의 품질 향상이나 기능 수정 등으로 인해 예고 없이 변경될 수 있습니다. 제품에 대한 자세한 사항은 ㈜슈프리마로 문의 바랍니다. BioEntry Plus
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 34 Producer : GPL Ghostscript 8.15 Create Date : 2013:03:12 11:45:39 Modify Date : 2013:03:12 11:45:39 Title : (Microsoft PowerPoint - \(BEWI\)BioEntry W_InstallationGuide_V0.1_EN_130312.ppt [\310\243\310\257 \270\360\265\345]) Creator : PScript5.dll Version 5.2.2 Author : hjlimEXIF Metadata provided by EXIF.tools