Users Manual
BioEntry W IP Based Fingerprint Access Control Installation Guide (Ver 0.1) 0 1) www.suprema.co.kr BioEntry W Contents Safety precautions Basics of fingerprint recognition How to place a finger Product d Contents Front Side 10 Bottom and Back Side 11 Product Dimension 12 Cables and Connectors 13 Installation of Wall-mount Bracket 14 Power Connection 15 Ethernet Connection 16 RS485 Connection 18 Relay Connection 20 Digital Input Connection 23 Wiegand Output 25 Network Default Setting 26 Installation Reference 27 Electrical Specification 30 Troubleshooting 31 Device cleaning 32 FCC Rules 33 S ifi i Specifications 34 ⒸCopyright 2007 Suprema Inc. BioEntry W Safety precautions The list below is to keep user’s safety and prevent any loss. Please read carefully before use. Do not install the device in a place subject to direct sun light, humidity, dust or soot. Do not place a magnet near the pr oduct. Magnetic objects such as magnet, CRT, TV, monitor or spe aker may damage the device. Do not place the device next to heating equipments. Be careful not to let liquid like water, drinks or chemicals leak inside the device. Clean the device often to remove dust on it. In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. ⒸCopyright 2007 Suprema Inc. BioEntry W Safety precautions The list below is to keep user’s safety and prevent any loss. Please read carefully before use. Do not drop the device. Do not damage the device. Do not disassemble, repair or alter the device. Do not let children touch the device without supervision. Do not use the device for any other purpose than specified. Contact your nearest dealer in case of a trouble or problem. ⒸCopyright 2007 Suprema Inc. BioEntry W Basics of fingerprint recognition What is fingerprint recognition? Process of fingerprint recognition Fingerprint g p is an individual’s own biometric information and does not change g throughout his/her life. Fingerprint recognition is a technology that verifies or identifies an individual using such fingerprint information. Free from the risk of theft or loss, fingerprint recognition technology is being widely used in security systems replacing PIN or cards. Fingerprint consists of ridges and valleys. Ridge is a flow of protruding skin in a fingerprint while valley is a hollow between two ridges. Each individual has different pattern of ridges and valleys and finger recognition makes use of such originality and uniqueness of these patterns patterns. Fingerprint sensor generates 2-dimentional fingerprint image using different technology. According to the sensing technology, fingerprint sensors are classified into optical, capacitive, or thermal. Fingerprint template is a collection of numeric data representing the features of a fingerprint. Fingerprint templates are saved inside the memory of BioStation and used for identification identification. Secure way to protect personal information To avoid privacy concern, Suprema’s fingerprint products do not save fingerprint images itself. It is impossible to reconstruct a fingerprint image from a fingerprint template which is just numeric data of the features of a fingerprint. ⒸCopyright 2007 Suprema Inc. BioEntry W How to place a finger Suprema’s fingerprint products show an outstanding recognition performance regardless of the user’s fingerprint skin condition or the way of fingerprint positioning. However, following tips are recommended to get more optimal fingerprint recognition performance. Select a finger to enroll It is recommended to use an index finger or a middle finger. Thumb ring or little finger is relatively more difficult to place in a correct position Thumb, position. How to place a finger on a sensor Place a finger Pl fi such h that th t it completely l t l covers the th sensor area with ith maximum contact. t t Place core part of a fingerprint to the center of a sensor. People tend to place upper part of a finger. The core of a fingerprint is a center where the spiral of ridges is dense. Usually core of fingerprint is the opposite side of the lower part of a nail nail. Place a finger such that the bottom end of a nail is located at the center of a sensor. If a finger is placed as in the right picture, only a small area of a finger is captured. So it is recommended to place a finger as shown in the left picture. ⒸCopyright 2007 Suprema Inc. BioEntry W How to place a finger Tips for different fingerprint conditions Suprema’s fingerprint g p products are designed to scan fingerprint g p smoothly y regardless of the conditions of a finger skin. However, in case a fingerprint is not read well on the sensor, please refer to the followings tips. If a finger is stained with sweat or water, scan after wiping moisture off. If a finger is covered with dust or impurities, scan after wiping them off. If a finger is way too dry dry, place after blowing warm breath on the finger tip tip. Tips for fingerprint enrollment In fingerprint recognition, enrollment process is very important. When enrolling a fingerprint, please try to place a finger correctly with care. In case of low acceptance ratio ratio, the following actions are recommended recommended. Delete the enrolled fingerprint and re-enroll the finger. Enroll the same fingerprint additionally. Try another finger if a finger is not easy to enroll due to scar or worn-out. For the case when an enrolled fingerprint cannot be used due to injury or holding a baggage, it is recommended to enroll more than two fingers per user. ⒸCopyright 2007 Suprema Inc. BioEntry W Product Contents Basic Contents BioEntry W Wall mounting screws – 2 ea Star-shaped Star shaped screws Star-shaped small wrench Software CD Wall-mounting metal bracket ⒸCopyright 2007 Suprema Inc. BioEntry W Product Contents Optional accessories Secure I/O 12V power adaptor Plastic stand USB fingerprint scanner for enrollment on PC ⒸCopyright 2007 Suprema Inc. BioEntry W Front Side Front LED Status per Color LED Display current status using seven different colors RF card reading part Place an RF card over the picture Fingerprint sensing part Place a finger on a sensor surface Green : Authorization Success R d:A Red Authorization th i ti F Failil Pink : On Processing Flicker Blue/Sky-Blue Color per 2sec : Normal Flicker Red/Pink Color per 2sec : Locked Flicker Blue/Red Color per 2sec : Initialized Time due to the Internal Battery Discharge Flicker Blue/Yellow Color per 2sec : DHCP Fail Flicker Red Color per 2sec : Failed. Please contact to your distributor or Suprema Flicker Yellow Color per 2sec : Waiting Input Flicker Yellow Color per 1sec : Receiving IP Address from DHCP server 10 ⒸCopyright 2007 Suprema Inc. BioEntry W Bottom and Back Side Star-shaped screw hole for fixing a body to a metal bracket wiegand input or wiegand output power and RS485 ethernet (TCP/IP) digital input and relay output Network Indicate LED switch it h : Network N t kR Resett (Refer to “Network Default Setting” pages for details) 11 ⒸCopyright 2007 Suprema Inc. BioEntry W Product Dimension 50 172 172 Front 40 44 157 Side Metal Bracket (unit : mm) 12 ⒸCopyright 2007 Suprema Inc. BioEntry W Cables( all cables use the shielded cables) 13 ⒸCopyright 2007 Suprema Inc. BioEntry W Installation of Wall-mount Bracket Fix wall mount bracket on a wall using wall mounting screws Hook BioEntry W on the wall mount bracket Wall mounting screws Fix BioEntry W and wall mounting bracket using a star shape screw. Star-shaped screw Star-shaped wrench ⒸCopyright 2007 Suprema Inc. 14 BioEntry W Power Connection UPS (optional) DC Power supply RS-485 Power 12V (Red) Power GND (Black) Signal GND (Black/White) TRX+ (Blue/White) TRX (Yellow/White) TRXBioEntry W Recommended power supply z 12V ± 10%, 10% att lleastt 500 500mA. z Comply with standard IEC/EN 60950-1. z To share the power with other devices, use a power supply with higher current ratings. 15 ⒸCopyright 2007 Suprema Inc. BioEntry W Ethernet Connection 16 ⒸCopyright 2007 Suprema Inc. BioEntry W Ethernet Connection (Direct connection with PC) To connect BioEntry W with a PC directly, connect both devices with a straight CAT-5 cable. As the BioEntry W supports auto MDI/MDIX feature, it is not necessary to use a crossover type cable. 17 ⒸCopyright 2007 Suprema Inc. BioEntry W RS485 Connection for Host Communication (Black/White) (Blue/White) (Yellow/White) (Black/White) (Blue/White) (Yellow/White) 18 ⒸCopyright 2007 Suprema Inc. BioEntry W RS485 Connection for Secure I/O (Black/White) (Blue/White) (Yellow/White) (Black/White) (Blue/White) (Y ll /Whit ) (Yellow/White) Max number of devices z Maximum numbers of devices in an RS485 loop are two(2) devices (BioStation or BioEntry W) and four(4) Secure I/Os 19 ⒸCopyright 2007 Suprema Inc. BioEntry W Relay Connection – Fail safe lock 20 ⒸCopyright 2007 Suprema Inc. BioEntry W Relay Connection – Fail secure lock 21 ⒸCopyright 2007 Suprema Inc. BioEntry W Relay Connection - Automatic door RTE Switch Presence Detector BioEntry W Automatic ti Door Door Controller (7) Normally ll O Open / N.O. N O (Gray/White) (G /Whit ) (6) Common (GREEN/White) (5) Normally Closed / N.C. (Orange/White) 22 ⒸCopyright 2007 Suprema Inc. BioEntry W Digital Input Connection (RTE, Door sensor) 23 ⒸCopyright 2007 Suprema Inc. BioEntry W Digital Input Connection (Alarm, Emergency sw) BioEntry W ( ) SW1 GND ((Black/White)) (4) (3) SW1 Input (Brown) (2) SW0 GND (Black/White) (1) SW0 Input (Purple) Switch #1 Switch #2 24 ⒸCopyright 2007 Suprema Inc. BioEntry W Wiegand Input/Output Wiegand ega d Input put Wiegand Output 25 ⒸCopyright 2007 Suprema Inc. BioEntry W Network Default Setting In case of forgetting network setting of BioEntry W (TCP/IP or RS-485 setting) during installation or using BioEntry W, user can initialize network setting (TCP/IP or RS-485 setting) by using DIP SW installed on the back panel of BioEntry W. Please refer to the figures in below. How to initialize Network Setting 1. Turn On BioEntry W power. 2. Please push the Switch (Please refer to Fig.1) 3. After turning on BioEntry Plus power, user can modify TCP/IP or RS-485 setting what user wants. z Network Default Setting - TCP/IP Address : 192.168.0.1 - Not checked “Use Server” - RS-485 : PC Connection, 115200bps 4 Please modify TCP/IP or RS 4. RS-485 485 setting and save itit. 4. Please make DIP SW #2 “OFF” (Please refer to Fig.2) 5. After recycling BioEntry W power power, please check the modified TCP/IP or RS-485 setting. 26 ⒸCopyright 2007 Suprema Inc. BioEntry W Installation Reference 1 - Stand alone Door Sensor Door Lock Exit Button BioEntry W LAN PC Enroll Scanner 27 ⒸCopyright 2007 Suprema Inc. BioEntry W Installation Reference 2 – Secure RS485 Door Sensor Door Lock Exit Button Secure I/O BioEntry W LAN PC Enroll Scanner 28 ⒸCopyright 2007 Suprema Inc. BioEntry W Installation Reference 3 – Network Door Zone 1 (Anti passback) RS485 BioStation RS485 BioEntry W BioEntry W Secure I/O LAN PC S Server Enroll E ll Scanner PC Client BioStation Secure I/O BioEntry W Exit Button RS485 PC Client Door Zone 2 (Anti passback) 29 ⒸCopyright 2007 Suprema Inc. BioEntry W Electrical Specification Min. Typ. Max. Notes 10.8 12 13.2 Use regulated DC power adaptor only Power Voltage (V) Current (mA) 250 Switch Input VIH (V) TBD VIL (V) TBD Pull-up resistance (Ω) 4.7k VOH (V) VOL (V) 0.8 P ll Pull-up resistance i t (Ω) 4 7k 4.7k Switching capacity (A) 0.3 Switching power (resistive) 30W 37.5VA DC AC Switching voltage (V) 110 125 DC AC The input ports are pulled up with 4.7k resistors TTL/Wiegand Output The outputs ports are open drain type, pulled up with 4.7k resistors internally Relay 30V DC 125V AC 30 ⒸCopyright 2007 Suprema Inc. BioEntry W Troubleshooting Fingerprint can not be read well or it takes too long. Fingerprint is entered but authorization keeps failing. Check whether the user is restricted by door zone or time zone zone. Inquire of administrator whether the enrolled fingerprint has been deleted frin the device for some reason. Authorized but door is not opened. Check whether a finger g or fingerprint g p sensor is stained with sweat,, water,, or dust Retry after wiping off finger and fingerprint sensor with dry towel. If a fingerprint is way too dry, blow on the finger and retry. Check whether the time is set as lock time time. Check whether an antipass back mode is in use. In antipass back mode, only who entered can exit. Device doesn’t operate though power is connected. Check whether a device and a bracket is well connected to each other. If not, a tamper switch is activated and the device doesn’t doesn t work. work 31 ⒸCopyright 2007 Suprema Inc. BioEntry W Device cleaning Wipe out machine surface with dry towel or cloth. In case tthere e e is s dust o or impurities pu t es o on tthe e se sensor so o of tthe e BioStation, oStat o , wipe pe o off the t e surface su ace with dry towel. Note that if the sensor is cleaned by detergent, benzene or thinner, surface is damaged and fingerprint can’t be entered. 32 ⒸCopyright 2007 Suprema Inc. BioEntry W FCC Rules Changes or modifications not expressly approved by the manufacturer responsible could void the user's authority y to operate the equipment. q p for compliance RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Information to User This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, user and can radiate radio frequency energy and if not installed and used in accordance with the instructions and, instructions, may cause harmful interference to radio communications. However, there is no guaranteee that interference will not occur in a particular installation; if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Caution 1. 2. 3. 4. Reorient / Relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help 33 ⒸCopyright 2007 Suprema Inc. BioEntry W Specifications Item Specification CPU 400MH DSP 400MHz Fingerprint sensor 500dpi Optical / Capacitive sensor User capacity 5000 users (10,000 templates) Log capacity 50,000 events Matching speed Less than 1 second Operation mode Fingerprint, RF Card, RF card + Fingerprint Network Interface TCP/IP, RS485 Internal relay Deadbolt EM lock Deadbolt, lock, door strike strike, automatic door TTL I/O 2 inputs for exit switch and door sensor Wiegand In/Out 1 Port (Wiegand Input or Wiegand Output is used according to the configuration.) Sound and Interface Multi-color LED and multi-tone buzzer Rated Voltage DC 12V (Min. 500mA and above) (When sharing the power with a device such as electric door lock, enough power is required considering the power requirement for the connected device.) Card option 13.56MHz Mifare Card Size 50 x 160 x 37 mm (Width x Height x Depth) Certified KCC, CE, FCC 34 ⒸCopyright 2007 Suprema Inc. Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu, Seongnam, Gyeonggi, 463-863 Korea E-mail : support@supremainc.com Website : www.supremainc.com www supremainc com Functions and specifications of the product are subject to changes without notice due to quality enhancement or function update. update For any inquiry on the product product, please contact Suprema Inc. Inc
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2012:05:16 10:38:13+09:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2012:06:02 09:59:57+04:30 Metadata Date : 2012:06:02 09:59:57+04:30 Format : application/pdf Title : Microsoft PowerPoint - BioEntry W_InstallationGuide_V0.1_English [호환 모드] Creator : Document ID : uuid:90ac2785-18dd-4887-85d6-00ab68d7cc01 Instance ID : uuid:e96ebb6c-7df0-479d-b9eb-5b84645e23eb Page Count : 35 Author :EXIF Metadata provided by EXIF.tools