Suprema BEWMOC BioEntry W User Manual

Suprema Inc. BioEntry W Users Manual

Users Manual

Download: Suprema BEWMOC BioEntry W User Manual
Mirror Download [FCC.gov]Suprema BEWMOC BioEntry W User Manual
Document ID1714672
Application IDG9K0ryf4/fcoPvzXnDG2+Q==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize237.31kB (2966333 bits)
Date Submitted2012-06-04 00:00:00
Date Available2012-06-05 00:00:00
Creation Date2012-05-16 10:38:13
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2012-06-02 09:59:57
Document TitleMicrosoft PowerPoint - BioEntry W_InstallationGuide_V0.1_English [호환 모드]
Document CreatorPScript5.dll Version 5.2

BioEntry W
IP Based Fingerprint Access Control
Installation Guide
(Ver 0.1)
0 1)
www.suprema.co.kr
BioEntry W
Contents
Safety precautions
Basics of fingerprint recognition
How to place a finger
Product
d Contents
Front Side
10
Bottom and Back Side
11
Product Dimension
12
Cables and Connectors
13
Installation of Wall-mount Bracket
14
Power Connection
15
Ethernet Connection
16
RS485 Connection
18
Relay Connection
20
Digital Input Connection
23
Wiegand Output
25
Network Default Setting
26
Installation Reference
27
Electrical Specification
30
Troubleshooting
31
Device cleaning
32
FCC Rules
33
S ifi i
Specifications
34
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Safety precautions
„
The list below is to keep user’s safety and prevent any loss. Please read carefully before
use.
Do not install the device in a
place subject to direct sun light,
humidity, dust or soot.
Do not place a magnet near the pr
oduct. Magnetic objects such as
magnet, CRT, TV, monitor or spe
aker may damage the device.
Do not place the device next to
heating equipments.
Be careful not to let liquid like
water, drinks or chemicals leak
inside the device.
Clean the device often to remove
dust on it.
In cleaning, do not splash water
on the device but wipe it out with
smooth cloth or towel.
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Safety precautions
„
The list below is to keep user’s safety and prevent any loss. Please read carefully before
use.
Do not drop the device.
Do not damage the device.
Do not disassemble, repair or
alter the device.
Do not let children touch the
device without supervision.
Do not use the device for any
other purpose than specified.
Contact your nearest dealer in
case of a trouble or problem.
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Basics of fingerprint recognition
„
What is fingerprint recognition?
„
Process of fingerprint recognition
„
Fingerprint
g p
is an individual’s own biometric information and does not change
g throughout
his/her life.
Fingerprint recognition is a technology that verifies or identifies an individual using such fingerprint
information.
Free from the risk of theft or loss, fingerprint recognition technology is being widely used in security
systems replacing PIN or cards.
Fingerprint consists of ridges and valleys. Ridge is a flow of protruding skin in a fingerprint while
valley is a hollow between two ridges. Each individual has different pattern of ridges and valleys
and finger recognition makes use of such originality and uniqueness of these patterns
patterns.
Fingerprint sensor generates 2-dimentional fingerprint image using different technology. According
to the sensing technology, fingerprint sensors are classified into optical, capacitive, or thermal.
Fingerprint template is a collection of numeric data representing the features of a fingerprint.
Fingerprint templates are saved inside the memory of BioStation and used for identification
identification.
Secure way to protect personal information
To avoid privacy concern, Suprema’s fingerprint products do not save fingerprint images itself. It is
impossible to reconstruct a fingerprint image from a fingerprint template which is just numeric data
of the features of a fingerprint.
ⒸCopyright 2007 Suprema Inc.
BioEntry W
How to place a finger
Suprema’s fingerprint products show an outstanding recognition performance regardless of the user’s fingerprint
skin condition or the way of fingerprint positioning. However, following tips are recommended to get more optimal
fingerprint
recognition performance.
„
Select a finger to enroll
„
It is recommended to use an index finger or a middle finger.
Thumb ring or little finger is relatively more difficult to place in a correct position
Thumb,
position.
How to place a finger on a sensor
Place a finger
Pl
fi
such
h that
th t it completely
l t l covers the
th sensor area with
ith maximum
contact.
t t
Place core part of a fingerprint to the center of a sensor.
ƒ
ƒ
ƒ
ƒ
People tend to place upper part of a finger.
The core of a fingerprint is a center where the spiral of ridges is dense.
Usually core of fingerprint is the opposite side of the lower part of a nail
nail.
Place a finger such that the bottom end of a nail is located at the center of a sensor.
If a finger is placed as in the right picture, only a small area of a finger is captured. So it is
recommended to place a finger as shown in the left picture.
ⒸCopyright 2007 Suprema Inc.
BioEntry W
How to place a finger
„
Tips for different fingerprint conditions
Suprema’s
fingerprint
g p
products are designed
to scan fingerprint
g p
smoothly
y regardless
of the
conditions of a finger skin. However, in case a fingerprint is not read well on the sensor, please
refer to the followings tips.
ƒ If a finger is stained with sweat or water, scan after wiping moisture off.
ƒ If a finger is covered with dust or impurities, scan after wiping them off.
ƒ If a finger is way too dry
dry, place after blowing warm breath on the finger tip
tip.
„
Tips for fingerprint enrollment
In fingerprint recognition, enrollment process is very important. When enrolling a fingerprint, please
try to place a finger correctly with care.
In case of low acceptance ratio
ratio, the following actions are recommended
recommended.
ƒ Delete the enrolled fingerprint and re-enroll the finger.
ƒ Enroll the same fingerprint additionally.
ƒ Try another finger if a finger is not easy to enroll due to scar or worn-out.
For the case when an enrolled fingerprint cannot be used due to injury or holding a baggage, it is
recommended to enroll more than two fingers per user.
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Product Contents
„
Basic Contents
BioEntry W
Wall mounting screws – 2 ea
Star-shaped
Star
shaped screws
Star-shaped small wrench
Software CD
Wall-mounting metal bracket
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Product Contents
„
Optional accessories
Secure I/O
12V power adaptor
Plastic stand
USB fingerprint scanner
for enrollment on PC
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Front Side
„
Front
LED Status per Color
LED
Display current status using
seven different colors
RF card reading part
Place an RF card over the
picture
Fingerprint sensing part
Place a finger on a sensor
surface
Green : Authorization Success
R d:A
Red
Authorization
th i ti F
Failil
Pink : On Processing
Flicker Blue/Sky-Blue Color per 2sec : Normal
Flicker Red/Pink Color per 2sec : Locked
Flicker Blue/Red Color per 2sec : Initialized
Time due to the Internal Battery Discharge
Flicker Blue/Yellow Color per 2sec : DHCP
Fail
Flicker Red Color per 2sec : Failed. Please
contact to your distributor or Suprema
Flicker Yellow Color per 2sec : Waiting Input
Flicker Yellow Color per 1sec : Receiving IP
Address from DHCP server
10
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Bottom and Back Side
Star-shaped screw hole for fixing a body to a metal bracket
wiegand input or wiegand output
power and RS485
ethernet (TCP/IP)
digital input and relay output
Network Indicate LED
switch
it h : Network
N t
kR
Resett
(Refer to “Network Default Setting” pages for details)
11
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Product Dimension
50
172
172
Front
40
44
157
Side
Metal Bracket
(unit : mm)
12
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Cables( all cables use the shielded cables)
13
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Installation of Wall-mount Bracket
„
Fix wall mount bracket on a wall using wall mounting
screws
Hook BioEntry W on the wall mount bracket
„
Wall mounting
screws
„
Fix BioEntry W and wall mounting bracket using a star
shape screw.
Star-shaped
screw
Star-shaped
wrench
ⒸCopyright 2007 Suprema Inc.
14
BioEntry W
Power Connection
UPS
(optional)
DC
Power supply
RS-485
Power 12V (Red)
Power GND (Black)
Signal GND (Black/White)
TRX+ (Blue/White)
TRX (Yellow/White)
TRXBioEntry W
„
Recommended power supply
z 12V
± 10%,
10% att lleastt 500
500mA.
z Comply with standard IEC/EN 60950-1.
z To share the power with other devices, use a power supply with higher current ratings.
15
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Ethernet Connection
16
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Ethernet Connection (Direct connection with PC)
„
To connect BioEntry W with a PC directly, connect both devices with a straight CAT-5 cable.
As the BioEntry W supports auto MDI/MDIX feature, it is not necessary to use a crossover
type cable.
17
ⒸCopyright 2007 Suprema Inc.
BioEntry W
RS485 Connection for Host Communication
(Black/White)
(Blue/White)
(Yellow/White)
(Black/White)
(Blue/White)
(Yellow/White)
18
ⒸCopyright 2007 Suprema Inc.
BioEntry W
RS485 Connection for Secure I/O
(Black/White)
(Blue/White)
(Yellow/White)
„
(Black/White)
(Blue/White)
(Y ll /Whit )
(Yellow/White)
Max number of devices
z Maximum
numbers of devices in an RS485 loop are two(2) devices (BioStation or BioEntry W)
and four(4) Secure I/Os
19
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Relay Connection – Fail safe lock
20
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Relay Connection – Fail secure lock
21
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Relay Connection - Automatic door
RTE Switch
Presence
Detector
BioEntry W
Automatic
ti
Door
Door
Controller
(7) Normally
ll O
Open / N.O.
N O (Gray/White)
(G /Whit )
(6) Common (GREEN/White)
(5) Normally Closed / N.C. (Orange/White)
22
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Digital Input Connection (RTE, Door sensor)
23
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Digital Input Connection (Alarm, Emergency sw)
BioEntry W
( ) SW1 GND ((Black/White))
(4)
(3) SW1 Input (Brown)
(2) SW0 GND (Black/White)
(1) SW0 Input (Purple)
Switch #1
Switch #2
24
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Wiegand Input/Output
„
Wiegand
ega d Input
put
„
Wiegand Output
25
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Network Default Setting
„
In case of forgetting network setting of BioEntry W (TCP/IP or RS-485 setting) during
installation or using BioEntry W, user can initialize network setting (TCP/IP or RS-485
setting) by using DIP SW installed on the back panel of BioEntry W. Please refer to the
figures in below.
How to initialize Network Setting
1. Turn On BioEntry W power.
2. Please push the Switch (Please refer to Fig.1)
3. After turning on BioEntry Plus power, user can modify
TCP/IP or RS-485 setting what user wants.
z Network Default Setting
- TCP/IP Address : 192.168.0.1
- Not checked “Use Server”
- RS-485 : PC Connection, 115200bps
4 Please modify TCP/IP or RS
4.
RS-485
485 setting and save itit.
4. Please make DIP SW #2 “OFF” (Please refer to Fig.2)
5. After recycling BioEntry W power
power, please check the
modified TCP/IP or RS-485 setting.
26
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Installation Reference 1 - Stand alone
Door Sensor
Door Lock
Exit Button
BioEntry W
LAN
PC
Enroll Scanner
27
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Installation Reference 2 – Secure
RS485
Door Sensor
Door Lock
Exit Button
Secure I/O
BioEntry W
LAN
PC
Enroll Scanner
28
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Installation Reference 3 – Network
Door Zone 1 (Anti passback)
RS485
BioStation
RS485
BioEntry W
BioEntry W
Secure I/O
LAN
PC S
Server Enroll
E ll Scanner
PC Client
BioStation
Secure I/O
BioEntry W
Exit Button
RS485
PC Client
Door Zone 2 (Anti passback)
29
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Electrical Specification
Min.
Typ.
Max.
Notes
10.8
12
13.2
Use regulated DC power adaptor only
Power
Voltage (V)
Current (mA)
250
Switch Input
VIH (V)
TBD
VIL (V)
TBD
Pull-up resistance (Ω)
4.7k
VOH (V)
VOL (V)
0.8
P ll
Pull-up
resistance
i t
(Ω)
4 7k
4.7k
Switching capacity (A)
0.3
Switching power
(resistive)
30W
37.5VA
DC
AC
Switching voltage (V)
110
125
DC
AC
The input ports are pulled up with 4.7k resistors
TTL/Wiegand Output
The outputs ports are open drain type, pulled up with 4.7k resistors
internally
Relay
30V DC
125V AC
30
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Troubleshooting
„
Fingerprint can not be read well or it takes too long.
„
Fingerprint is entered but authorization keeps failing.
„
Check whether the user is restricted by door zone or time zone
zone.
Inquire of administrator whether the enrolled fingerprint has been deleted frin the device for some
reason.
Authorized but door is not opened.
„
Check whether a finger
g or fingerprint
g p
sensor is stained with sweat,, water,, or dust
Retry after wiping off finger and fingerprint sensor with dry towel.
If a fingerprint is way too dry, blow on the finger and retry.
Check whether the time is set as lock time
time.
Check whether an antipass back mode is in use. In antipass back mode, only who entered can exit.
Device doesn’t operate though power is connected.
Check whether a device and a bracket is well connected to each other. If not, a tamper switch is
activated and the device doesn’t
doesn t work.
work
31
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Device cleaning
„
„
„
Wipe out machine surface with dry towel or cloth.
In case tthere
e e is
s dust o
or impurities
pu t es o
on tthe
e se
sensor
so o
of tthe
e BioStation,
oStat o , wipe
pe o
off the
t e surface
su ace with
dry towel.
Note that if the sensor is cleaned by detergent, benzene or thinner, surface is damaged and
fingerprint can’t be entered.
32
ⒸCopyright 2007 Suprema Inc.
BioEntry W
FCC Rules
Changes or modifications not expressly approved by the manufacturer responsible
could void the user's authority
y to operate
the equipment.
q p
for compliance
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS
Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
Information to User
This equipment has been tested and found to comply with the limit of a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, user and can radiate radio frequency energy
and if not installed and used in accordance with the instructions
and,
instructions, may cause
harmful interference to radio communications. However, there is no guaranteee that
interference will not occur in a particular installation; if this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Caution
1.
2.
3.
4.
Reorient / Relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit difference from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help
33
ⒸCopyright 2007 Suprema Inc.
BioEntry W
Specifications
Item
Specification
CPU
400MH DSP
400MHz
Fingerprint sensor
500dpi Optical / Capacitive sensor
User capacity
5000 users (10,000 templates)
Log capacity
50,000 events
Matching speed
Less than 1 second
Operation mode
Fingerprint, RF Card, RF card + Fingerprint
Network Interface
TCP/IP, RS485
Internal relay
Deadbolt EM lock
Deadbolt,
lock, door strike
strike, automatic door
TTL I/O
2 inputs for exit switch and door sensor
Wiegand In/Out
1 Port (Wiegand Input or Wiegand Output is used according to the configuration.)
Sound and Interface
Multi-color LED and multi-tone buzzer
Rated Voltage
DC 12V (Min. 500mA and above)
(When sharing the power with a device such as electric door lock, enough power is
required considering the power requirement for the connected device.)
Card option
13.56MHz Mifare Card
Size
50 x 160 x 37 mm (Width x Height x Depth)
Certified
KCC, CE, FCC
34
ⒸCopyright 2007 Suprema Inc.
Suprema Inc.
16F Parkview Office Tower, Jeongja-dong, Bundang-gu,
Seongnam, Gyeonggi, 463-863 Korea
E-mail : support@supremainc.com
Website : www.supremainc.com
www supremainc com
Functions and specifications of the product are subject to changes without notice due to quality
enhancement or function update.
update For any inquiry on the product
product, please contact Suprema Inc.
Inc

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2012:05:16 10:38:13+09:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2012:06:02 09:59:57+04:30
Metadata Date                   : 2012:06:02 09:59:57+04:30
Format                          : application/pdf
Title                           : Microsoft PowerPoint - BioEntry W_InstallationGuide_V0.1_English [호환 모드]
Creator                         : 
Document ID                     : uuid:90ac2785-18dd-4887-85d6-00ab68d7cc01
Instance ID                     : uuid:e96ebb6c-7df0-479d-b9eb-5b84645e23eb
Page Count                      : 35
Author                          : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TKWBEWMOC

Navigation menu