Suprema BLNOC BioLite-NET User Manual

Suprema Inc. BioLite-NET

User manual

Download: Suprema BLNOC BioLite-NET User Manual
Mirror Download [FCC.gov]Suprema BLNOC BioLite-NET User Manual
Document ID1031617
Application IDEXmQFR1SG1dMSQSDxdjGOg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize76.15kB (951881 bits)
Date Submitted2008-11-17 00:00:00
Date Available2008-11-17 00:00:00
Creation Date2008-11-10 21:00:09
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2008-11-10 21:00:09
Document TitleMicrosoft PowerPoint - BLN_Installation Guide.ppt [호환 모드]
Document CreatorPScript5.dll Version 5.2
Document Author: mooy2

www.supremainc.com
BioLite NET
Innovative Fingerprint Terminal
User guide((ver
ver 1.0 )1.0)
User Guide
Product Contents
„
Basic Contents
Product Contents
E-ring
Main Body
Default
Sub bbracket
c e
(optional)
Wall-mounting metal bracket
Recommended power supply
12V ±10%, at least 2500mA for BioLite-NET
alone installation.
Comply with standard IEC/EN 60950-1
(CE Certification).
To share the power with other devices,
use a power supply with higher current ratings.
Shrinking Tube
12V power adaptor
(optional)
Before Start
ⒸCopyright 2008 Suprema Inc.
Cable spec.
PIN
POWER + 485
POWER + (12Vd
(12Vdc))
POWER GND
485 GND
485 +
485 -
WIRE
RED
BLACK
WHITE(Black String)
BLUE(Black String)
YELLOW(Black String)
PIN
RELAY
NORMAL CLOSE
COMMON
NORMAL OPEN
WIRE
ORANGE(White String)
GREEN(White String)
GRAY(White String)
Ethernet
PIN
SWITCH
ERX ERX +
ETX ETX +
WIRE
YELLOW
BLUE
ORANGE
PINK
Switch & Wiegand
PIN
SWITCH&WIEGAND
WGND
WDATA 1
WDATA 0
GND
SWIN 1
GND
SWIN 0
WIRE
BLACK
WHITE
GREEN
GRAY
BROWN
GRAY
PURPLE
Power & 485
Relay
Before Start
ⒸCopyright 2008 Suprema Inc.
Power Connection
„
Recommended power supply
12V ± 10%, at least 1000mA.
z To share the power with other devices, use a power supply with higher current ratings.
ⒸCopyright 2008 Suprema Inc.
Relay Connection – Fail safe lock
ⒸCopyright 2008 Suprema Inc.
Relay Connection – Fail secure lock
ⒸCopyright 2008 Suprema Inc.
Relay Connection - Automatic door
ⒸCopyright 2008 Suprema Inc.
Door switch connection
BioLite NET
Door Status
(1) SW0 Input (PURPLE)
(2) SW0 GND (GRAY)
(3) SW1 Input (BROWN)
(4) SW1 GND (GRAY)
Request
To
Exit
ⒸCopyright 2008 Suprema Inc.
Switch connection (Alarm, Emergency switches)
ⒸCopyright 2008 Suprema Inc.
RS485 connection for host communication
10
Before Start
ⒸCopyright 2008 Suprema Inc.
RS485 connection for Secure I/O
(1) Power 12V (Red)
(2) Power GND (Black)
(3) Signal GND (White)
(4) TRX+ (Blue)
(5) TRX- (Yellow)
Power
Power
BioLite NET (Master)
*Enable termination
((optional,
ti
l see Note1)
N t 1)
(1) Power 12V (Red)
((2)) Power GND ((Black))
(3) Signal GND (White)
(4) TRX+ (Blue)
(5) TRX- (Yellow)
BioLite NET (Slave)
TRX GND
TRX+
TRXSecure I/O
TRX GND
TRX+
TRX-
...
*E bl ttermination
*Enable
i ti
(optional, see Note1)
Secure I/O
As short as possible (Note 2)
Important Notes
1. For bus termination, only the devices at both ends of the bus should be terminated.
T enable
To
bl ttermination
i ti on th
the RS232
RS232-485
485 converter,
t refer
f to
t the
th converter’s
t ’ manual.l
2. The stubs should be as short as practical
11
ⒸCopyright 2008 Suprema Inc.
Installation Reference - Stand alone
12
ⒸCopyright 2008 Suprema Inc.
Installation Reference – Using Secure I/O, 2 door
RTE
switch
Switch 0
Internal
Relay
RS485
Secure
I/O
Relay 0
Door 1
Door 0
Door
Status
RTE
switch
Switch 0
Switch 1
Switch 1
Door
Status
13
ⒸCopyright 2008 Suprema Inc.
14
ⒸCopyright 2008 Suprema Inc.
Installation Reference – Using RFID card
item
Model
Transmit
Receive
Modulation
Communication
Channel
Mode
„
content
BioLite-NET(BLN-OC)
13.56MHz
13.56MHz
ASK
Single propagation
Single channel
1:1
Using RFID card (13.56MHz = Mifare model only)
In case 1:1 mode is set as RF Card
z If the 1:1 mode is set as Card Only, user can access just by placing the card to BioLite-NET
without any additional procedure.
15
ⒸCopyright 2008 Suprema Inc.
Installation Reference – LAN
RTE
switch
Switch 0
Network hub
Ethernet
RS485
Secure
I/O
Relay 0
Door 1
Switch 1
„
„
Door
Status
If you select Network on initial UI menu, Network Setup menus appear on the display.
If you select TCP/IP on network menu, following menus appear on the display.
LAN TYPE
Max conn
SSL
DHCP
IP Address, gateway, subnet
Setting : Disable/Ethernet
Used when connected to PC via Ethernet using RJ45 connector on the rear of the device.
Setting : 1/4/8/16
Max number of clients that can access the device at the same time.
Setting : Use/not use.
It sets Use or Not Use of SSL between the TEST
TEST_UI
UI and BioLite
BioLite-NET.
NET
Setting : Use/not use
Using DHCP, you can receive IP address and other necessary setting from server automatically.
Check whether an appropriate DHCP server is available in your network environment before use.
Without using DHCP, IP address, gateway, and subnet need to be entered manually. Inquire
necessary settings to network administrator.
ⒸCopyright 2008 Suprema Inc.
16
Electrical Specification
Min.
Typ.
Max.
Notes
10 8
10.8
12
13 2
13.2
Use regulated DC power adaptor only
Power
Voltage (V)
Current (mA)
250
RTC Battery
Voltage (V)
Current (mAH)
2.7
3.3
Lithium-ion rechargeable battery
11
Switch Input
VIH (V)
TBD
VIL (V)
TBD
Pull-up resistance (Ω)
4.7k
VOH (V)
VOL (V)
0.8
Pull-up resistance (Ω)
4.7k
Switching capacity (A)
0.3
Switching power (resistive)
30W
37.5VA
DC
AC
Switching voltage (V)
110
125
DC
AC
The input ports are pulled up with 4.7k resistors
TTL/Wiegand Output
The outputs ports are open drain type, pulled up with 4.7k resistors
internally
Relay
30V DC
125V AC
17
ⒸCopyright 2008 Suprema Inc.
18
ⒸCopyright 2008 Suprema Inc.
Troubleshooting
„
Fingerprint can not be read well or it takes too long.
„
Fingerprint is entered but authorization keeps failing.
„
Check whether the time is set as lock time.
time
Check whether an antipass back mode is in use. In antipass back mode, only who entered can exit.
Device doesn’t operate though power is connected.
„
Check whether the user is restricted by door zone or time zone
Inquire of administrator whether the enrolled fingerprint has been deleted from the device for some
reason
Authorized but door is not opened.
„
Check whether a finger
g or fingerprint
g p
sensor is stained with sweet,, water or dust
Retry after wiping off finger and fingerprint sensor with dry towel.
If a fingerprint is way too dry, blow on the finger and retry.
Check whether a device and a bracket is well connected to each other. If not, a tamper switch is
activated and the device doesn’t
doesn t work.
work
RTC Battery caution.
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
19
ⒸCopyright 2008 Suprema Inc.
FCC Rules
20
ⒸCopyright 2008 Suprema Inc.
Tel : 82-31-710-2400
Fax : 82-31-783-4506
21
ⒸCopyright 2008 Suprema Inc.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2008:11:10 21:00:09+09:00
Create Date                     : 2008:11:10 21:00:09+09:00
Format                          : application/pdf
Title                           : Microsoft PowerPoint - BLN_Installation Guide.ppt [호환 모드]
Creator                         : mooy2
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:e66ac678-ec80-44d7-87a1-678579297602
Instance ID                     : uuid:7850e0ce-4c77-4b5e-a282-c7c82b121098
Page Count                      : 21
Author                          : mooy2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TKWBLNOC

Navigation menu