User manual
www.supremainc.com BioLite solo Innovative Fingerprint Terminal User guide((ver ver 1.0 )1.0) User Guide CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. INFORMATION TO USER: This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation; if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Reorient / Relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help Product Contents Basic Contents Product Contents E-ring Main Body Default Sub bracket (optional) Wall-mounting metal bracket 12V power adaptor (optional) Shrinking Tube Before Start ⒸCopyright 2008 Suprema Inc. Cable spec. Power & 485 Relay Switch PIN POWER + 485 POWER + (12Vdc) POWER GND 485 GND 485 + 485 - WIRE RED BLACK WHITE(Black String) BLUE(Black String) YELLOW(Black String) PIN RELAY NORMAL CLOSE COMMON NORMAL OPEN WIRE ORANGE(White String) GREEN(White String) GRAY(White String) PIN SWITCH SWIN 0 GND SWIN 1 GND WIRE PURPLE BLACK Brown BLACK Recommended power supply 12V ± 10%, at least 1000mA. z To share the power with other devices, use a power supply with higher current ratings. Before Start ⒸCopyright 2008 Suprema Inc. Relay Connection – Fail safe lock ⒸCopyright 2008 Suprema Inc. Relay Connection – Fail secure lock ⒸCopyright 2008 Suprema Inc. Relay Connection - Automatic door ⒸCopyright 2008 Suprema Inc. Door switch connection ⒸCopyright 2008 Suprema Inc. Switch connection (Alarm, Emergency switches) ⒸCopyright 2008 Suprema Inc. RS485 connection for host communication Before Start ⒸCopyright 2008 Suprema Inc. RS485 connection for Secure I/O (1) Power 12V (Red) (2) Power GND (Black) (3) Signal GND (White) (4) TRX+ (Blue) (5) TRX- (Yellow) Power Power BioEntry Plus (Master) *Enable termination (optional, see Note1) (1) Power 12V (Red) (2) Power GND (Black) (3) Signal GND (White) (4) TRX+ (Blue) (5) TRX- (Yellow) BioEntry Plus (Slave) TRX GND TRX+ TRXSecure I/O TRX GND TRX+ TRX- ... *Enable termination (optional, see Note1) Secure I/O As short as possible (Note 2) Important Notes 1. For bus termination, only the devices at both ends of the bus should be terminated. To enable termination on the RS232-485 converter, refer to the converter’s manual. 2. The stubs should be as short as practical 10 ⒸCopyright 2008 Suprema Inc. Installation of Wall-mount Bracket 11 ⒸCopyright 2008 Suprema Inc. Installation Reference - Stand alone 12 ⒸCopyright 2008 Suprema Inc. Installation Reference – Using Secure I/O, 2 door 13 ⒸCopyright 2008 Suprema Inc. Electrical Specification Min. Typ. Max. Notes 10.8 12 13.2 Use regulated DC power adaptor only Power Voltage (V) Current (mA) 250 Switch Input VIH (V) TBD VIL (V) TBD Pull-up resistance (Ω) 4.7k VOH (V) VOL (V) 0.8 Pull-up resistance (Ω) 4.7k Switching capacity (A) 0.3 Switching power (resistive) 30W 37.5VA DC AC Switching voltage (V) 110 125 DC AC The input ports are pulled up with 4.7k resistors TTL/Wiegand Output The outputs ports are open drain type, pulled up with 4.7k resistors internally Relay 30V DC 125V AC 14 ⒸCopyright 2008 Suprema Inc. 15 ⒸCopyright 2008 Suprema Inc. 16 ⒸCopyright 2008 Suprema Inc. Tel : 82-31-710-2400 Fax : 82-31-783-4506 17 ⒸCopyright 2008 Suprema Inc.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 18 Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:16851dab-cd08-4fc2-98da-2f74e5a02d1c Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2008:06:17 09:31:27+09:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2008:06:20 09:20:22+09:00 Metadata Date : 2008:06:20 09:20:22+09:00 Document ID : uuid:f519f7b3-83d7-4264-a573-a47069573d0a Instance ID : uuid:e6556953-0adc-43d1-b8ff-d62dbb71ebba Format : application/pdf Title : Microsoft PowerPoint - BLS_Installation Guide_0616.ppt Creator :EXIF Metadata provided by EXIF.toolsAuthor :