Suprema BRM-10 BioEntry Plus Dummy Reader User Manual

Suprema Inc. BioEntry Plus Dummy Reader Users Manual

Users Manual

Download: Suprema BRM-10 BioEntry Plus Dummy Reader User Manual
Mirror Download [FCC.gov]Suprema BRM-10 BioEntry Plus Dummy Reader User Manual
Document ID1853301
Application IDigsoXwAzrqNokCRH7MddXQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize61.63kB (770433 bits)
Date Submitted2012-12-05 00:00:00
Date Available2012-12-05 00:00:00
Creation Date2012-09-27 09:36:15
Producing SoftwarepdfFactory Pro 3.52 (Windows XP Professional Korean)
Document Lastmod2012-11-29 11:43:39
Document TitleBRM-10_InstallationGuide_V1.0_English_Certification.ppt [호환 모드]
Document CreatorpdfFactory Pro www.pdffactory.com
Document Author: hslee

IP based Fingerprint Access Control
Installation Guide
(ver 1.0)
www.supremainc.com
Contents
Safety precautions
Basics of fingerprint recognition
How to place a finger
Product Contents
Front Side
10
Bottom and Back Side
11
Product Dimension
12
Cables and Connectors
13
Installation of Wall-mount Bracket
14
Power Connection
15
RS485 Connection
16
Digital Input Connection
18
Wiegand Output
20
Electrical Specification
21
General Specification
22
Troubleshooting
23
Device cleaning
24
FCC Rules
25
Caution
26
ⒸCopyright 2007 Suprema Inc.
Safety precautions
The list below is to keep user’s safety and prevent any loss. Please read carefully before
use.
Do not install the device in a
place subject to direct sun light,
humidity, dust or soot.
Do not place a magnet near the pr
oduct. Magnetic objects such as
magnet, CRT, TV, monitor or spe
aker may damage the device.
Do not place the device next to
heating equipments.
Be careful not to let liquid like
water, drinks or chemicals leak
inside the device.
Clean the device often to remove
dust on it.
In cleaning, do not splash water
on the device but wipe it out with
smooth cloth or towel.
ⒸCopyright 2007 Suprema Inc.
Safety precautions
The list below is to keep user’s safety and prevent any loss. Please read carefully before
use.
Do not drop the device.
Do not damage the device.
Do not disassemble, repair or
alter the device.
Do not let children touch the
device without supervision.
Do not use the device for any
other purpose than specified.
Contact your nearest dealer in
case of a trouble or problem.
ⒸCopyright 2007 Suprema Inc.
Basics of fingerprint recognition
What is fingerprint recognition?
Process of fingerprint recognition
Fingerprint is an individual’s own biometric information and does not change throughout his/her life.
Fingerprint recognition is a technology that verifies or identifies an individual using such fingerprint
information.
Free from the risk of theft or loss, fingerprint recognition technology is being widely used in security
systems replacing PIN or cards.
Fingerprint consists of ridges and valleys. Ridge is a flow of protruding skin in a fingerprint while
valley is a hollow between two ridges. Each individual has different pattern of ridges and valleys
and finger recognition makes use of such originality and uniqueness of these patterns.
Fingerprint sensor generates 2-dimentional fingerprint image using different technology. According
to the sensing technology, fingerprint sensors are classified into optical, capacitive, or thermal.
Fingerprint template is a collection of numeric data representing the features of a fingerprint.
Fingerprint templates are saved inside the memory of BioStation and used for identification.
Secure way to protect personal information
To avoid privacy concern, Suprema’s fingerprint products do not save fingerprint images itself. It is
impossible to reconstruct a fingerprint image from a fingerprint template which is just numeric data
of the features of a fingerprint.
ⒸCopyright 2007 Suprema Inc.
How to place a finger
Suprema’s fingerprint products show an outstanding recognition performance regardless of the user’s fingerprint
skin condition or the way of fingerprint positioning. However, following tips are recommended to get more optimal
fingerprint recognition performance.
Select a finger to enroll
It is recommended to use an index finger or a middle finger.
Thumb, ring or little finger is relatively more difficult to place in a correct position.
How to place a finger on a sensor
Place a finger such that it completely covers the sensor area with maximum contact.
Place core part of a fingerprint to the center of a sensor.
§
§
§
§
People tend to place upper part of a finger.
The core of a fingerprint is a center where the spiral of ridges is dense.
Usually core of fingerprint is the opposite side of the lower part of a nail.
Place a finger such that the bottom end of a nail is located at the center of a sensor.
If a finger is placed as in the right picture, only a small area of a finger is captured. So it is
recommended to place a finger as shown in the left picture.
ⒸCopyright 2007 Suprema Inc.
How to place a finger
Tips for different fingerprint conditions
Suprema’s fingerprint products are designed to scan fingerprint smoothly regardless of the
conditions of a finger skin. However, in case a fingerprint is not read well on the sensor, please
refer to the followings tips.
§ If a finger is stained with sweat or water, scan after wiping moisture off.
§ If a finger is covered with dust or impurities, scan after wiping them off.
§ If a finger is way too dry, place after blowing warm breath on the finger tip.
Tips for fingerprint enrollment
In fingerprint recognition, enrollment process is very important. When enrolling a fingerprint, please
try to place a finger correctly with care.
In case of low acceptance ratio, the following actions are recommended.
§ Delete the enrolled fingerprint and re-enroll the finger.
§ Enroll the same fingerprint additionally.
§ Try another finger if a finger is not easy to enroll due to scar or worn-out.
For the case when an enrolled fingerprint cannot be used due to injury or holding a baggage, it is
recommended to enroll more than two fingers per user.
ⒸCopyright 2007 Suprema Inc.
Product Contents
Basic Contents
BioEntry Plus
Wall-mounting metal bracket
Wall mounting screws – 2 ea
Star-shaped screws
Star-shaped small wrench
Software CD
3 pin, 4 pin, 5 pin cables – each 1 ea
ⒸCopyright 2007 Suprema Inc.
Front Side
Front
LED Status per Color
RF card reading part
Place an RF card over the
picture
LED
Display current status using
seven different colors
Green : Authorization Success
Red : Authorization Fail
Pink : On Processing
Flicker Blue/Sky-Blue Color per 2sec : Normal
Flicker Red/Pink Color per 2sec : Locked
Flicker Blue/Red Color per 2sec : Initialized
Time due to the Internal Battery Discharge
Flicker Red Color per 2sec : Failed. Please
contact to your distributor or Suprema
Flicker Yellow Color per 2sec : Waiting Input
Fingerprint sensing part
Place a finger on a sensor
surface
10
ⒸCopyright 2007 Suprema Inc.
Bottom and Back Side
Bottom
Star-shaped screw hole for fixing a body to a metal bracket
Back
3 pin connector – wiegand output
5 pin connector – power and RS485
4 pin connector – digital input
DIP switch – RS485 termination setting
(Refer to “RS485 Connection” pages for details)
11
ⒸCopyright 2007 Suprema Inc.
Product Dimension
50
160
160
Front
40
37
150
Side
135
Metal Bracket
(unit : mm)
12
ⒸCopyright 2007 Suprema Inc.
Cables and Connectors
Power and RS485
PIN
PIN DESCRIPTION
POWER +12V
POWER GND
RS -485 GND
RS -485 TRX+
RS -485 TRX-
WIRE
RED
BLACK
GRAY
BLUE
YELLOW
PIN
PIN DESCRIPTION
WIEGAND DATA0
WIEGAND DATA1
WIEGAND GND
WIRE
GREEN
WHITE
BLACK
PIN
PIN DESCRIPTION
SW1 INPUT
SW1 GND
SW2 INPUT
SW2 GND
WIRE
YELLOW
BLACK
GREEN
BLACK
Wiegand output
Digital Inputs and
13
ⒸCopyright 2007 Suprema Inc.
Installation of Wall-mount Bracket
Fix wall mount bracket on a wall using wall mounting
screws
Hook BioEntry Plus on the wall mount bracket
Wall mounting
screws
Fix BioStation and wall mounting bracket using a star
shape screw.
Star-shaped
screw
Star-shaped
wrench
14
ⒸCopyright 2007 Suprema Inc.
Power Connection
Recommended power supply
± 10%, at least 1500mA.
l Comply with standard IEC/EN 60950-1.
l To share the power with other devices, use a power supply with higher current ratings.
l 12V
15
ⒸCopyright 2007 Suprema Inc.
RS485 Connection for Host Communication
16
ⒸCopyright 2007 Suprema Inc.
RS485 Connection for Secure I/O
Max number of devices
l Maximum
numbers of devices in an RS485 loop are two(2) devices (BioStation or BioEntry
Plus) and four(4) Secure I/Os
17
ⒸCopyright 2007 Suprema Inc.
Digital Input Connection (RTE, Door sensor)
18
ⒸCopyright 2007 Suprema Inc.
Digital Input Connection (Alarm, Emergency sw)
19
ⒸCopyright 2007 Suprema Inc.
Wiegand Output
20
ⒸCopyright 2007 Suprema Inc.
Electrical Specification
Min.
Typ.
Max.
Notes
10.8
12
13.2
Use regulated DC power adaptor only
Power
Voltage (V)
Current (mA)
250
Switch Input
VIH (V)
TBD
VIL (V)
TBD
Pull-up resistance (Ω)
4.7k
VOH (V)
VOL (V)
0.8
Pull-up resistance (Ω)
4.7k
Switching capacity (A)
0.3
Switching power
(resistive)
30W
37.5VA
DC
AC
Switching voltage (V)
110
125
DC
AC
The input ports are pulled up with 4.7k resistors
TTL/Wiegand Output
The outputs ports are open drain type, pulled up with 4.7k resistors
internally
Relay
30V DC
125V AC
21
ⒸCopyright 2007 Suprema Inc.
General Specification
Item
Specification
CPU
400MHz DSP
Fingerprint Sensor
OC Model : Optical Sensor
IN/OUT
Switch Input x 2, Wiegand In/Out x 1 ,RS-485 x 1
Power Input Rate
DC12V, Max 250mA
Support Cards
BioEntry Plus Dummey Mifare OC Model (BRM-10)
- 13.56MHz Mifare Card Read/Write
- 13.56MHz ISO14443A Card CSN Read
Size
50 x 160 x 38 (Width x Height x Depth)
Certified
KCC, CE, FCC
22
ⒸCopyright 2007 Suprema Inc.
Troubleshooting
Fingerprint can not be read well or it takes too long.
Fingerprint is entered but authorization keeps failing.
Check whether the user is restricted by door zone or time zone.
Inquire of administrator whether the enrolled fingerprint has been deleted frin the device for some
reason.
Authorized but door is not opened.
Check whether a finger or fingerprint sensor is stained with sweat, water, or dust
Retry after wiping off finger and fingerprint sensor with dry towel.
If a fingerprint is way too dry, blow on the finger and retry.
Check whether the time is set as lock time.
Check whether an antipass back mode is in use. In antipass back mode, only who entered can exit.
Device doesn’t operate though power is connected.
Check whether a device and a bracket is well connected to each other. If not, a tamper switch is
activated and the device doesn’t work.
23
ⒸCopyright 2007 Suprema Inc.
Device cleaning
Wipe out machine surface with dry towel or cloth.
In case there is dust or impurities on the sensor of the BioStation, wipe off the surface with
dry towel.
Note that if the sensor is cleaned by detergent, benzene or thinner, surface is damaged and
fingerprint can’t be entered.
24
ⒸCopyright 2007 Suprema Inc.
FCC Rules
Changes or modifications not expressly approved by the manufacturer
responsible for compliance could void the user's authority to operate the
equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limit of a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, user and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guaranteee that interference will not occur in a particular
installation; if this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Caution
Warning
Information to User
1.
2.
3.
4.
Reorient / Relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit difference from that
to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help
25
ⒸCopyright 2007 Suprema Inc.
Caution
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
26
ⒸCopyright 2007 Suprema Inc.
Suprema Inc.
16F Parkview Office Tower, Jeongja-dong, Bundang-gu,
Seongnam, Gyeonggi, 463-863 Korea
E-mail : support@supremainc.com
Website : www.supremainc.com
Functions and specifications of the product are subject to changes without notice due to quality
enhancement or function update. For any inquiry on the product, please contact Suprema Inc.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : hslee
Create Date                     : 2012:09:27 09:36:15+09:00
Modify Date                     : 2012:11:29 11:43:39+09:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Creator                         : hslee
Title                           : BRM-10_InstallationGuide_V1.0_English_Certification.ppt [호환 모드]
Creator Tool                    : pdfFactory Pro www.pdffactory.com
Metadata Date                   : 2012:11:29 11:43:39+09:00
Producer                        : pdfFactory Pro 3.52 (Windows XP Professional Korean)
Document ID                     : uuid:8049b852-0496-484a-b043-efc068b50a13
Instance ID                     : uuid:119fbc39-d55c-43a1-b97e-3e9d788e8ce2
Page Count                      : 27
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TKWBRM-10

Navigation menu