User Manual
www.supremainc.com USER GUIDE FaceStation 2 English Version 1.0 EN 102.00.FS2 V1.00A Safety Instructions Contents Safety Instructions .......................................................................................... 4 Introduction ...................................................................................................... 6 Components ...................................................................................................................................................6 Name and function of each part ...............................................................................................................7 Cables and connectors ...........................................................................................................................9 Correct face registration and authentication method...........................................................................10 Cautions for registering a face ...........................................................................................................10 Cautions for authenticating a face ....................................................................................................10 Admin Menu ................................................................................................... 11 All Menus ..................................................................................................................................................... 11 User ................................................................................................................. 12 Registering user information.....................................................................................................................12 Modifying user information.......................................................................................................................14 Delete All Users ..........................................................................................................................................14 View User Usage .........................................................................................................................................14 Authentication ............................................................................................... 15 Auth Mode ...................................................................................................................................................15 Modifying Auth Mode ..........................................................................................................................15 Delete Auth Mode ................................................................................................................................16 Add Auth Mode.....................................................................................................................................16 Operation .....................................................................................................................................................16 Face Recognition .........................................................................................................................................17 T&A Mode ....................................................................................................................................................17 Network .......................................................................................................... 18 Network Settings.........................................................................................................................................18 Ethernet ..................................................................................................................................................18 Wireless ...................................................................................................................................................19 Server ......................................................................................................................................................19 Serial Settings .............................................................................................................................................20 RS-485 .....................................................................................................................................................20 Display & Sound ........................................................................................... 21 Device ............................................................................................................. 22 Interphone ....................................................................................................................................................22 Relay .............................................................................................................................................................22 Date & Time ................................................................................................................................................22 Device Info ...................................................................................................................................................23 Memory Info ................................................................................................................................................23 USB Memory ................................................................................................................................................23 Restart Device .............................................................................................................................................23 Restore Default............................................................................................................................................23 Factory Default ............................................................................................................................................24 Delete the Root Certificate .......................................................................................................................24 Safety Instructions Event Log ....................................................................................................... 25 Search Log ...................................................................................................................................................25 Detail View Log...........................................................................................................................................25 Delete All Logs ............................................................................................................................................25 View Log Usage ..........................................................................................................................................26 Troubleshooting ............................................................................................ 27 Checklist before reporting a failure ........................................................................................................27 Product specifications .................................................................................. 28 Dimensions ...................................................................................................................................................29 FCC compliance information ...................................................................... 30 EU Declaration of Conformity (CE) ........................................................... 30 Appendices ..................................................................................................... 31 Escape clause ...............................................................................................................................................31 Copyright notice ..........................................................................................................................................31 Safety Instructions Safety Instructions Observe the following instructions to use the product safely and prevent any risk of injury or property damage. Warning Noncompliance with instructions can lead to serious injury or death. Installation Do not install the product in a location with direct sunlight, moisture, dust, or soot. • Fire or electric shock may occur. Do not install the product in a location with heat from an electric heater. • Fire or electric shock may occur due to overheating. Install the product in a dry location. • Otherwise, product damage or electric shock may occur due to moisture. Install the product in a location with no electromagnetic interference. • Otherwise, product damage or electric shock may occur. The user should not install or repair the product independently. • • Fire, electric shock, or personal injury may occur. If the product has been damaged due to independent installation or repair of the product by the user, free A/S service will not be provided. Operation Do not allow liquids such as water, beverages, or chemicals get into the product. • Fire, electric shock, or product damage may occur. Caution Noncompliance of instructions could lead to minor injury or product damage. Installation Do not install the power supply cable in a location where people pass by. • Product damage or physical injury may occur. Do not install the product near a highly magnetic object such as a magnet, TV, monitor (especially CRT), or speaker. • Product failure may occur. Use only a D.C 12 V and 2.5 A or higher power supply adaptor. • If the proper power supply is not used, the product may not operate properly. Use a separate power supply for the Secure I/O 2, electric lock, and FaceStation 2, respectively. • If connecting and using the power supply to these devices together, the devices may malfunction. When installing a number of devices, allow a space of at least 10cm between the devices for installation. • Otherwise, one device may affect the RF performance of other devices, resulting in a malfunction. Safety Instructions Operation Do not drop the product or apply an impact to the product. • Product failure may occur. Manage the password with care; do not to disclose it to others and change it periodically. • Otherwise, illegal intrusion may occur. Do not press the buttons on the product forcibly or using a sharp tool. • Product failure may occur. When cleaning the product, wipe the product with a soft and dry cloth. Do not apply water, benzene, or alcohol. • These may cause product failure. FaceStation 2 uses a capacitive screen and buttons. If the environment is moist from wet weather, or the product surface is smeared with a large amount of water, wipe the product off with a dry towel before using it. RTC battery Replacing the battery with an incorrect type of battery may cause explosion. Discard the battery according to appropriate regional or international waste regulations. Introduction Introduction Components PVC anchor (4 EA) FaceStation 2 Wall-mount bracket Diode (1 EA) Connection cable (2 pins 1 EA, 3 pins 1 EA, 4 pins 4 EA) Ferrite core (1 EA) Fixing screw (4 EA) 120Ω resistor (1 EA) Drilling template Quick guide Note • Components may vary according to the installation environment. • For additional content regarding product installation, visit the Suprema website (www.suprema.co.kr) and view the installation guide. Introduction Name and function of each part RF card authentication unit Microphone LCD screen Camera IR camera TTL input (4 pins) RS-485 (4 pins) Relay (3 pins) Wiegand input (4 pins) Power supply (2 pins) Wiegand output (4 pins) Ethernet USB memory slot Mini USB cable slot Speaker Name Description Microphone Delivers the voice of the user when the interphone is connected. LCD screen Provides UI for operation. IR camera Captures IR images. Camera Captures actual images. RF card authentication unit Scans the card for entrance. Speaker Delivers sound. USB memory slot Connects USB memory. Mini USB cable slot Will be supported in the future. TTL input (4 pins) Connects the TTL input cable. RS-485 (4 pins) Connects the RS-485 cable. Relay (3 pins) Connects the relay cable. Introduction Power supply (2 pins) Connects the power supply cable. Ethernet Connects the Ethernet cable. Wiegand input (4 pins) Connects the Wiegand input cable. Wiegand output (4 pins) Connects the Wiegand output cable. Introduction Cables and connectors Power Pin Name Color PWR +VDC PWR GND Red (white stripe) Black (white stripe) Relay Pin Name Color RLY NO RLY COM RLY NC White Blue Orange Pin Name Color 485 TRXP 485 TRXN 485 GND SH GND Blue Yellow Black Gray Pin Name Color TTL IN0 TTL IN1 TTL GND SH GND Red Yellow Black Gray RS-485 TTL input Wiegand input and output Pin Name Color WG D0 WG D1 WG GND SH GND Green White Black Gray Introduction Correct face registration and authentication method Cautions for registering a face • When registering a face, maintain a distance of 40cm to 80cm between the device and the face. • Be careful not to change the facial expression. (smiling face, drawn face, wink, etc.) • If you do not follow the instructions on the screen, the face registration may take longer or may fail. • Be careful not to cover the eyes or eyebrows. • Do not wear hats, masks, sunglasses or eyeglasses. • Be careful not to display two faces on the screen. Register one person at a time. • It is recommended for a user wearing glasses to register both faces with and without glasses. Cautions for authenticating a face • Ensure that the face appears inside the guideline displayed on the screen of the device. • If glasses have been changed, authentication may fail. If the face without glasses has been registered, authenticate the face without glasses. If only the face with glasses has been registered, authenticate the face with the previously worn glasses again. • If a part of the face is covered with a hat, a mask, an eye patch, or sunglasses authentication may fail. Do not cover the face; allow the device to recognize both the eyebrows and the face. 10 Admin Menu Admin Menu All Menus Press and authenticate with the Admin level credential. Select the desired menu. Note • If the administrator has not been designated, the menu screen will be displayed when you press 11 User User Registering user information The user information, including the face, can be registered. Press and authenticate with the Admin level credential. Press User > . The face registration wizard will begin. To proceed with the face registration wizard, press Next. To skip, press Skip and go to step 5. If you have pressed Next, register the face according to the instructions on the screen. Face registration is carried out in 3 steps. (1) Registering the front face (2) Moving the face up and down (3) Moving the face to the left and right When the face registration wizard is used, only the user's face is registered. Modify other information by pressing Edit after registering the face. 12 User Note • When registering a face, maintain a distance of 40cm to 80cm between the device and the face. • Be careful not to change the facial expression. (smiling face, drawn face, wink, etc.) • If you do not follow the instructions on the screen, the face registration may take longer or may fail. • Be careful not to cover the eyes or eyebrows. • Do not wear hats, masks, sunglasses or eyeglasses. • Be careful not to display two faces on the screen. Register one person at a time. • It is recommended for a user wearing glasses to register both faces with and without glasses. If you have pressed Skip, select and set the desired item. • : Take a picture of a user with the built-in camera. • • Name: Enter the user name. ID: Enter the user ID you wish to register. Numbers between 1 and 4294967295 can be entered for ID. If you have changed User ID Type to Alphanumeric, you can use a combination of alphabetic characters and numbers as ID. • Face: Register a face for user authentication. Press press • and register a face according to the instructions on the screen. To register another face, again. Card: Register a card for user authentication. Press and scan the card that will be assigned to the user. To register an additional card, press again. • PIN: Enter the PIN you wish to use. Enter the PIN you wish to use, and then reenter the same PIN for confirmation. Enter a number between 4 and 16 digits to prevent leaking. • Validity period: Set a Start Date and End Date to use the user account. When you press the first date, you can set Start Date, and when you press the second date, you can set End Date. Operator Level: Select the level you wish to assign to a user. • • Face Group: Select a face group for the user. Face groups can be used only when Group Matching is enabled, and these groups can be registered only in BioStar 2. • • Access Group: Select an access group for the user. Access groups can only be registered in BioStar 2. Private Auth Mode: Change the authentication method according to the user. Note Available menus vary according to the set operator level. • None: This is the general user level; menus cannot be accessed. • Full Administrator: All menus can be accessed. • Configuration: AUTHENTICATION, DISPLAY & SOUND, DEVICE and NETWORK menus can be accessed. • User Management: USER menu can be accessed. When you press OK, settings will be saved. 13 User Modifying user information User Management or Administrator can modify the registered user information. A user’s face or card can be added, and the PIN and level can be modified. Press and authenticate with the Admin level credential. Press User > Select your search terms. You can search for a user by User ID, Name, Face and Card. Select a user you wish to modify and modify the information by referring to Registering user information. • To select a user, press and then press OK. Note • Access Group can be registered in BioStar 2. For detailed contents regarding registering an access group, refer to the BioStar 2 Administrator Manual. Delete All Users You can delete all registered users at once. Press and authenticate with the Admin level credential. Press User > and select Delete All or select a user you wish to delete. When you press OK, all registered users will be deleted. View User Usage You can see the number of registered users, faces, and cards at a glance. Press and authenticate with the Admin level credential. Press User > 14 Authentication Authentication Auth Mode Modifying Auth Mode You can set the authentication method and schedule according to each credential. Press and authenticate with the Admin level credential. Press AUTHENTICATION > Auth Mode. Press to add an auth mode or press an auth mode you wish to modify. Pressing the icon will delete the selected credential, and pressing Set the desired auth mode and select a schedule. Classification Face Card ID will display an addable credential on the screen. Description • • • • • • • : Mode allowing authentication with a face only. : Mode to authenticate with a face and PIN. : Mode allowing authentication with a card only : Mode allowing authentication with a card and then with a face. : Mode allowing authentication with a card and PIN. : Mode allowing authentication with a card and then with a face or PIN. : Mode allowing authentication with a card and then with both a face and PIN input. • : Mode allowing authentication by entering ID and then authenticating the face. • : Mode allowing authentication by entering ID and then a PIN. • : Mode allowing authentication by entering ID and then authenticating the face or entering a PIN. • : Mode allowing authentication by entering ID and then using both face authentication and PIN input. When you press OK, settings will be saved. Note • A schedule can be set in BioStar 2. If there is no set schedule, only Always can be selected. • For detailed contents regarding setting a schedule, refer to BioStar 2 Administrator's manual. 15 Authentication Delete Auth Mode Press and authenticate with the Admin level credential. Press AUTHENTICATION > Auth Mode. Press and select an item to delete. When you press OK, the selected item will be deleted. Add Auth Mode Press and authenticate with the Admin level credential. Press AUTHENTICATION > Auth Mode. Press Set the desired auth mode by pressing , then select a schedule. When you press OK, the auth mode will be added. Operation Press and authenticate with the Admin level credential. Press AUTHENTICATION and then modify the items below Operation. • Ambient Brightness: Detect the ambient brightness and adjust the intensity of IR LED. Change settings according to the installation environment. • • Motion Sensor: Set the sensitivity for detecting motion near the device. Auth Timeout: If the authentication is not completed during the set time, the authentication will fail. • Face Pose Variation: Set the sensitivity for the position, angle, and distance of a face when registering the face. Set high if you wish to obtain a detailed face template • • Enroll Timeout: If a face is not registered during the set time, the face registration will be canceled. Matching Timeout: If the matching is not completed during the set time, the authentication will fail. 16 Authentication Face Recognition Change settings regarding face authentication. Press and authenticate with the Admin level credential. Press AUTHENTICATION and then modify the items below Face Recognition. • • Security Level: Set the security level for 1:N authentication. Group Matching: Check whether or not to use Group Matching. If Group Matching is used, you can increase the authentication speed by designing various users’ faces in a group. Note • Group Matching can be set in BioStar 2. For detailed contents, refer to the BioStar 2 Administrator Manual. T&A Mode You can set how to register T&A Mode. Press and authenticate with the Admin level credential. Press AUTHENTICATION then modify the items below T&A Mode. Select and set the desired item. • T&A Mode: Set the method to use T&A mode. • • • T&A Code: Register a new T&A code. T&A Required: Set to require a user to select a T&A event when authenticating. Job Code: Select whether or not to use Job Code. 17 Network Network Network Settings You can change the network settings of the device. Ethernet Press and authenticate with the Admin level credential. Press NETWORK > Ethernet. • DHCP: Set whether or not to use DHCP. If DHCP setting is disabled, the user can modify Device Port, IP Address, Gateway, Subnet Mask, and DNS. • • • Device Port: Set the device port. IP Address: View the IP address of the device. To modify, disable DHCP setting. Gateway: View the gateway of the device. To modify, disable DHCP setting. • • Subnet Mask: View the subnet mask of the device. To modify, disable DHCP setting. DNS server: Set the DNS server address. To modify, disable DHCP setting. To modify network information manually, disable DHCP setting. You can modify Device Port, IP Address, Gateway, Subnet Mask and DNS. Note • Ethernet cannot be used at the same time as Wireless. 18 Network Wireless Press and authenticate with the Admin level credential. Press NETWORK > Wireless. The list of available networks for connection will be displayed. Select the network to which you wish to connect and enter the password. When you press OK, the connection to the wireless network will be made. To set the network information of the wireless LAN manually, press setting. You can modify IP Address, Gateway, Subnet Mask and DNS. of the network name you wish to use and disable DHCP Note • Wireless cannot be used at the same time as Ethernet. • To connect to Wireless, a wireless router is required. For content regarding the installation and configuration of a wireless router, refer to the user manual of the wireless router. Server Press and authenticate with the Admin level credential. Press NETWORK > Server. • • • Connection Mode: When you select Device -> Server, you can send a connection signal from the device to a server with the input information directly. When you select Server -> Device, Server IP, Server URL and Server Port cannot be entered. Server IP: Enter the IP address of the PC on which BioStar 2 is installed. Input is accepted only when Device -> Server is set for Connection Mode. Server URL: Enter server URL instead of Server IP. Input is accepted only when Device -> Server is set for Connection Mode. • Server Port: Enter the port of the PC on which BioStar 2 is installed. Input is accepted only when Device -> Server is set for Connection Mode. 19 Network Serial Settings RS-485 Press and authenticate with the Admin level credential. Press NETWORK and then modify the items below Serial Setting. • RS-485: Select the RS-485 mode. • Baud Rate: Select the desired baud rate. 20 Display & Sound Display & Sound You can change the display and sound settings of the device. Press and authenticate with the Admin level credential. Press DISPLAY & SOUND. Change the desired item. • Home Screen: Select items to be displayed in the background of the home screen. When Custom is selected for Style, the user can modify the Home Screen directly. Edit the Home Screen by pressing and holding the desired object, then dragging and dropping it to a desired location. • • Language: Set the language you wish to use. Private Message: Set whether or not to use a Private Message, which will be displayed on the screen when the user authenticates. • Menu Timeout: Set the time (in seconds) for the menu screen to disappear automatically. If there is no button input during a set time, the screen will return to the home screen. • • Message Timeout: Set the time (in seconds) for a setting complete message or information message to disappear automatically. Backlight Timeout: Set the time (in seconds) to automatically turn off the lighting of the LCD screen. • • Voice Instruction: Set to use the voice instruction instead of alarm sounds. Volume: Set the volume. 21 Device Device Interphone Set the account and extensions of SIP interphone. Press and authenticate with the Admin level credential. Press DEVICE > Interphone. When Enable is set for Interphone, you can set the SIP account and the extensions. Ensure to set each item correctly. Relay You can set the open time and the input port of the exit button in the device. Press and authenticate with the Admin level credential. Press DEVICE > Relay. • • • Open Time: Set the duration for the door to remain open when standard user authentication has been carried out. Exit button: Select the input port where the exit button is connected. Switch: Select the relay type (N/O or N/C). Date & Time You can set date and time. Set the date and time accurately in order to collect accurate log data. Press and authenticate with the Admin level credential. Press DEVICE > Date & Time. Change the desired item. • Date & Time: Check the current date and time. To modify it directly, disable Time Sync. • Standard time zone: Set the time reference of the current location. 22 Device • • Time Sync: Synchronize the server and the time. If you wish to synchronize the server and the time, enable Time Sync. Date Format: Set the date format. You can select among YYYY/MM/DD, MM/DD/YYYY and DD/MM/YYYY. • Time Format: Set the time format. You can select either 24-Hour or AM/PM. Device Info You can view the model name, firmware version of Device ID, and MAC address. Press and authenticate with the Admin level credential. Press DEVICE > Device Info. You can view the information including Model Name, Device ID, HW, FW, Kernel, MAC, and WiFi MAC. Memory Info View the status of memory usage. Press and authenticate with the Admin level credential. Press DEVICE > Memory Info. USB Memory Connect USB Memory and import user information to the device or export log and user information from the device. Upgrade the firmware. Press and authenticate with the Admin level credential. Press DEVICE > USB Memory. Select the desired item and change the setting. • • • Import: Import user information from the connected USB memory. Export: Select information you wish to export to the connected USB memory. FW Upgrade: Upgrade the firmware if the firmware files are saved in the connected USB memory. Note The type of supported USB memory is as follows. If you use a different type of USB memory, the function may not operate normally. • Samsung Electronics: SUM-LSB 8GB, SUM-PSB 8GB, SUM-PSB 16GB, SUM-BSG 32GB • LG Electronics: XTICK J3 WINDY 8GB, SMART USB MU1 White 8GB, MU 1 USB 32GB, MU28GBC 32GB, XTICK MOBY J1 16GB • SanDisk: Cruzer 16GB, Cruzer Blade CZ50 4GB, Cruzer Blade CZ50 32GB, CZ48 Ultra USB 3.0 64GB, CZ80 USB3.0 64GB, CZ52 64GB, Cruzer Glide Z60 128GB, Cruzer Force CZ71 32GB • Sony: Micro Vault Click 8GB, MicroVault CLICK 16GB, USM-SA1 32GB • Transcend: JetFlash 760 8GB, JetFlash 760 32GB, JetFlash 500 8GB • Memorette: MINI500 8GB • A-DATA: S102 PRO 8GB • Trigem Pastel 8GB Restart Device The user can restart the device. Press and authenticate with the Admin level credential. Press DEVICE > Restart Device. To restart the device, press OK. To cancel, press Cancel. Restore Default Device settings, network settings, and operator levels will be reset. Press and authenticate with the Admin level credential. Press DEVICE > Restore Default. 23 Device To reset all device settings, select All settings and press OK. To reset all settings except for network settings, select Keep Network Settings and press OK. Note • When you reset, the operator level will be reset as well. After resetting, make sure to set the operator level again. • Language setting will not change after resetting. Factory Default Delete all the information saved in the device and the root certificate and restore default settings. Press and authenticate with the Admin level credential. Press DEVICE > Factory Default. To reset, press OK. Note • Factory Default menu can be used when the root certificate is saved in the device. Delete the Root Certificate Delete the root certificate saved in the device. Press and authenticate with the Admin level credential. Press DEVICE > Delete the Root Certificate. To delete the Root Certificate, press OK. Note • Delete the Root Certificate menu can be used only when the root certificate is saved in the device and Administrator has been designated. 24 Event Log Event Log Search Log You can set a condition and search a log. Press and authenticate with the Admin level credential. Press EVENT LOG. Press and change the condition. When you press OK, a log that matches the condition will be displayed on the screen. Detail View Log Press and authenticate with the Admin level credential. Press EVENT LOG. Select a log to view detailed contents. Delete All Logs You can delete all saved logs. Press and authenticate with the Admin level credential. Press EVENT LOG. To delete all logs, press and then press OK. To cancel, press Cancel. 25 Event Log View Log Usage You can check the status of log usage. Press and authenticate with the Admin level credential. Press EVENT LOG. Press 26 Troubleshooting Troubleshooting Checklist before reporting a failure Classification Problem Solution • • If the distance between the terminal and the bracket is too great, the device may not operate due to the temper switch. Check the adaptor or the power cable. • For a normal user PIN, request it from the administrator and reenter the PIN. • • If you have lost the Admin PIN, contact the installation company. Check if you entered the registered PIN correctly. • Check if you have changed your PIN recently. • If you cannot remember the PIN, request it from the administrator and reenter the PIN. The face has been registered but face authentication cannot be done smoothly, and errors occur frequently. Face authentication has suddenly stopped working. • Check ‘Cautions for registering a face’ and register the face again. • If there are a large number of registered faces, change Matching Timeout and try again. • Check ‘Cautions for authenticating a face’ and try again. Door Lock The door does not lock when I close the door. • The electric lock may be malfunctioning. Have an inspection performed by the installation company. • Time The time has suddenly become incorrect. FaceStation 2 is equipped with a built-in battery; however, if power is not supplied for a long period of time, the built-in battery may die, causing the time to become incorrect. For information on correcting the time, referring to Date & Time. • The administrator grants access permission in FaceStation 2, so only the administrator can access the Admin menu. If you need to access the Admin menu, you can have a PIN issued through a special procedure. Ask the installation company for the procedure to issue the password. Power The power is being supplied but the device does not operate. I forgot my PIN. PIN Face Admin Access I entered my PIN and pressed the OK button, but I still cannot open the door. I lost my Admin PIN, so I cannot access the Admin mode. • 27 Product specifications Product specifications Category Feature Biometric Credential RF Option Specification Face • FS2-D: EM, MIFARE, MIFARE Plus, DESFire/EV1, FeliCa, NFC, ISO14443A, ISO15693 • FS2-AWB: EM, HID Prox, MIFARE, MIFARE Plus, DESFire/EV1, FeliCa, iCLASS SE/SR, NFC, BLE, ISO14443A, ISO15693 RF read range* LFD CPU Memory LCD type LCD resolution Sound Operating temperature Storage temperature Operating humidity Storage humidity Camera type Camera resolution MIFARE/DESFire/iCLASS/ISO15693 : 50 mm / EM/HID Prox/Felica: 30 mm, BLE: 50 mm Supported 1.4 GHz Quad Core 8GB Flash + 1GB RAM 4” color TFT touch 800 x 480 24 bit/Voice DSP (echo cancel) -20 °C - 50 °C -40 °C - 70 °C 0% - 80%, non-condensing General 0% - 90%, non-condensing CMOS 720 x 480 Visual Lens: Diagonal 92.7° Camera angle IR Lens: Diagonal 58° Dimension (W x H x D) 141 mm x 164 mm x 125 mm Device: 628 g Weight Bracket: 74 g (Including washer and bolt) Certificates CE, FCC, KC, RoHS, REACH, WEEE Max. User (1:1) 30,000 Max. User (1:N) 3,000 Max. Template (1:1) 900,000 Capacity Max. Template (1:N) 90,000 Max. Text Log 5,000,000 Max. Image Log 50,000 Wi-Fi Supported (Built-in, IEEE802.11 b/g/n) Ethernet Supported (10/100/1000 Mbps, auto MDI/MDI-X) RS-485 1ch Host or Slave (Selectable) Wiegand 1ch Input, 1ch Output Interface TTL input 1ch Input Relay 1 Relay USB USB 2.0 (Host) Tamper Supported Voltage: 12 VDC Power Current: Max. 2.5 A Min.: 3 V Switch input VIH Max.: 5 V Switch input VIL Max.: 1 V Switch Pull-up resistance 4.7 kΩ (The input pots are pulled up with 4.7 kΩ.) Electrical Wiegand output VOH More than 4.8 V Wiegand output VOL Less than 0.2 V Wiegand output Pull-up resistance Internally pulled up with 1 kΩ Voltage: Max. 30 VDC Relay Current: Max. 1 A * RF read range will vary depending on installation environment. 28 Product specifications Dimensions (Unit: mm) 29 FCC compliance information FCC compliance information THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Modifications not expressly approved by the manufacturer may void the user's authority to operate the equipment under FCC rules. This appliance and its antenna must not be located or operated in conjunction with any other antenna or transmitter. A minimum separation distance of 20cm must be maintained between the antenna and individuals for this appliance to satisfy the RF exposure requirements. EU Declaration of Conformity (CE) This product is CE marked according to the provisions of the R&TTE Directive (1999/5/EC). Suprema Inc. hereby declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. This device is a class 1 radio device according to the directive. For more information, contact us using the following contact information. Suprema Inc. Website: https://www.supremainc.com Address: Parkview Tower F16, 248, Jeongjail-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea (Jeongja-dong 6) Tel: 031-783-4510 / Fax: 031-783-4517 30 Appendices Appendices Escape clause • The information in this manual is provided with regard to Suprema products. • The right to use is acknowledged only for products included in the terms and conditions of the sales agreement guaranteed by Suprema. The right of license to other intellectual property rights not discussed in this manual is not acknowledged. • Suprema does not guarantee or hold responsibility for the suitability and commerciality of the product for a specific purpose, or the infringement of patent, copyright, or other intellectual property rights with regard to sales or usage of Suprema products. • Do not use a Suprema product in situations related to medical, rescue of human lives, or maintenance of life, as a person may be injured or killed due to product malfunction. If an accident occurs while a consumer is using the product under the situations described as examples above, employees, subsidiaries, branches, affiliated companies, and distributors of Suprema do not accept responsibility, nor will they be liable for all related direct and indirect expenses or expenditures, including attorney fees, even if the consumer has discovered shortcomings in the product design or manufacturing process and claims this as a significant fault. • Suprema may modify the product size and specifications at any time without proper notice in order to improve the safety, function, and design of the product. Designers must keep in mind that functions or descriptions indicated as "to be implemented" or "undefined" may change at any time. Suprema will implement or define such functions or descriptions in the near future, and Suprema accepts no responsibility for compatibility issues and any other problems arising from such compatibility issues. • If you wish to obtain the newest specifications before ordering the product, contact Suprema through a Sales Representative or local distributor of Suprema. Copyright notice The copyright of this document is vested in Suprema. The rights of other product names, trademarks, and registered trademarks are vested in each individual or organization that owns such rights. 31 www.supremainc.com www.supremainc.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : SUPREMA Inc. Create Date : 2017:02:09 09:00:18+09:00 Modify Date : 2017:02:15 15:11:44+09:00 XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Metadata Date : 2017:02:15 15:11:44+09:00 Creator Tool : Word용 Acrobat PDFMaker 15 Document ID : uuid:d2fbb708-b636-442b-a625-0f34eb234dcc Instance ID : uuid:20d0d3fa-eec6-4e16-8bf1-8d60a947fc88 Subject : 2 Format : application/pdf Creator : SUPREMA Inc. Producer : Adobe PDF Library 15.0 Source Modified : D:20170208235715 Company : Saltlux Page Layout : SinglePage Page Mode : UseOutlines Page Count : 32EXIF Metadata provided by EXIF.tools