8 639 537 0 Operator Manual Chariot 3 IScrub 26 Windsor Sp Rider Scrubber Service Parts
2016-12-29
: Sweepscrub Windsor-Chariot-3-Iscrub-26-Sp-Rider-Scrubber-Service-Parts-Manual windsor-chariot-3-iscrub-26-sp-rider-scrubber-service-parts-manual 1791 file product_file
Open the PDF directly: View PDF .
Page Count: 57
Download | |
Open PDF In Browser | View PDF |
Chariot 3 iScrub 26 Scrubber Operating instructions (ENG) MODELS: CS26 1.006-150.0 CSC26 1.006-151.0 CSM26 1.006-158.0 CSCM26 1.006-159.0 CS26SP 1.006-152.0 CSC26SP 1.006-153.0 CSM26SP 1.006-160.0 CSCM26SP 1.006-161.0 From Serial Number (Ref No. 1*) * See Serial Number page in Spare Parts List or call manufacturer. 86395370-C 03/29/16 Machine Data Label / Overview Overview The Chariot Scrubber is a battery powered, stand-on, hard floor scrubber intended for commercial use. The appliance applies a cleaning solution onto a hard floor, scrubs the floor with brushes or pads, and then vacuums the soiled water back into the recovery tank. Warranty Registration Thank you for purchasing a Kärcher North America product. Warranty registration is quick and easy. Your registration will allow us to serve you better over the lifetime of the product. To register your product go to : http://warranty.karcherna.com/ For customer assistance: 1-800-444-7654 2 86395370 Operator Manual - Chariot 3 iScrub 26 Table of Contents Machine Data Label / Overview . . . . . . . . . . . . . . . . 2 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . 5 HAZARD INTENSITY LEVEL . . . . . . . . . . . . . . . . . . 7 Safety Label Locations . . . . . . . . . . . . . . . . . . . . . . . 9 Operations Technical Specifications . . . . . . . . . . . . . . . . . . . . . 10 How This Machine Works . . . . . . . . . . . . . . . . . . . . 12 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Drive Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Scrub Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Pre-Run Machine Inspection. . . . . . . . . . . . . . . . . . 20 Starting Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Emergency Stop Procedures . . . . . . . . . . . . . . . . . 20 Filling Solution Tank . . . . . . . . . . . . . . . . . . . . . . . . 20 Normal Scrubbing . . . . . . . . . . . . . . . . . . . . . . . . . . 21 To Begin Scrubbing . . . . . . . . . . . . . . . . . . . . . . . . 22 To Stop Scrubbing . . . . . . . . . . . . . . . . . . . . . . . . . 22 Double Scrub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Emptying and Cleaning Tanks . . . . . . . . . . . . . . . . 23 Solution Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Optional Chemical Metering System. . . . . . . . . . . . 23 Squeegee Disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Squeegee - Cylindrical . . . . . . . . . . . . . . . . . . . . . . 25 Maintenance Service Schedule . . . . . . . . . . . . . . . . . . . . . . . . . .27 Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Changing Batteries . . . . . . . . . . . . . . . . . . . . . . . . .32 Onboard Charger Programming . . . . . . . . . . . . . . .33 Squeegee - Disk . . . . . . . . . . . . . . . . . . . . . . . . . . .34 Squeegee - Cylindrical . . . . . . . . . . . . . . . . . . . . . .34 Squeegee Blades . . . . . . . . . . . . . . . . . . . . . . . . . .35 Scrub Deck - Disk . . . . . . . . . . . . . . . . . . . . . . . . . .36 Scrub Brushes . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 Finished Floors . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 Replacing or Installing Scrub Brushes - Disk . . . . .38 To Replace Scrub Brush Motors . . . . . . . . . . . . . . .39 Brush Motor Carbon Brush Replacement . . . . . . . .39 Scrub Deck - Cylindrical . . . . . . . . . . . . . . . . . . . . .40 Replacing or Installing Scrub Brushes - Cylindrical 41 Actuator Scrub Deck Removal / Replacement . . . .42 Scrub Deck Actuator Adjustment . . . . . . . . . . . . . .42 Circuit Protection. . . . . . . . . . . . . . . . . . . . . . . . . . .43 Solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 Solution Strainer . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Solenoid Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Chemical Bottle (Optional) . . . . . . . . . . . . . . . . . . .45 Flow Meter (Optional) . . . . . . . . . . . . . . . . . . . . . . .45 Vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 Recovery Tank Float Shut-off . . . . . . . . . . . . . . . . .47 To Repair or Replace Vacuum Motor . . . . . . . . . . .47 Drive Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Electric Parking Brake Engagement . . . . . . . . . . . .49 Drive Motor Carbon Brush Replacement . . . . . . . .49 Transporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Controller Fault Codes . . . . . . . . . . . . . . . . . . . . . .54 Suggested Spare Parts - Disk. . . . . . . . . . . . . . . . 56 Suggested Spare Parts - Cylindrical . . . . . . . . . . . 57 86395370 Operator Manual - Chariot 3 iScrub 26 3 How To Use This Manual This manual contains the following sections: • • • • • How to Use This Manual Safety Operations Maintenance Suggested Spare Parts The SAFETY section contains important information regarding hazardous or unsafe practices of the machine. Levels of hazards are identified that could result in product damage, personal injury, or severe injury resulting in death. The OPERATIONS section is to familiarize the operator with the operation and function of the machine. The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts. Parts may be ordered from authorized dealers. When placing an order for parts, the machine model and machine serial number are important. Refer to the MACHINE DATA box which is filled out during the installation of your machine. The MACHINE DATA box is located on the inside of the front cover of this manual. Model: Date of Purchase: The MAINTENANCE section contains preventive maintenance to keep the machine and its components in good working condition. They are listed in this general order: • • • • • • • Service Schedule Batteries Squeegee Scrub Brush Vacuum Drive Motor Troubleshooting Serial Number: Dealer: NOTE: The manual part number is located on the lower right corner of the front cover. Address: Phone Number: Sales Representative: The model and serial number of your machine is located on the back of the machine. 4 86395370 Operator Manual - Chariot 3 iScrub 26 Safety IMPORTANT SAFETY INSTRUCTIONS When using this machine, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. To reduce the risk of fire, electric shock, or injury: Use only indoors. Do not use outdoors or expose to rain. Use only as described in this manual. Use only manufacturer's recommended components and attachments. If the machine is not working properly, has been dropped, damaged, left outdoors, or dropped into water, return it to an authorized service center. Do not operate the machine with any openings blocked. Keep openings free of debris that may reduce airflow. This machine is not suitable for picking up hazardous dust. Machine can cause a fire when operating near flammable vapors or materials. Do not operate this machine near flammable fluids, dust or vapors. This machine is suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and offices for more than normal housekeeping purposes. Maintenance and repairs must be done by qualified personnel. If foam or liquid comes out of machine, switch off immediately. Disconnect battery before cleaning or servicing. Before the machine is discarded, the batteries must be removed and properly disposed of. Make sure all warning and caution labels are legible and properly attached to the machine. During operation, attention shall be paid to other persons, especially children. Before use, all covers and doors shall be put in the positions specified in the instructions. When leaving unattended, secure against unintentional movement. The machine shall only be operated by instructed and authorized persons. When leaving unattended, switch off or lock the main power switch to prevent unauthorized use. Only chemicals recommended by the manufacturer shall be used. This appliance has been designed for use with the brushes specified by the manufacturer. The fitting of other brushes may affect its safety. Do not use on surfaces having a gradient of over 10% (6 degrees). READ AND SAVE THESE INSTRUCTIONS 5 Safety MESURES DE SÉCURITÉ IMPORTANTES Lors de l'utilisation d'un appareil à batteries, il est nécessaire de respecter systématiquement des mesures de sécurité de base, comme suit: PRENEZ NOTE DE TOUTES CES MESURES AVANT D'UTILISER CETTE MACHINE. Pour réduire les risques d'incendie, de chocs électriques, ou de blessures: N'utiliser cette machine qu'en intérieur. Ne jamais l'utiliser à l'extérieur ou dans la pluie. N'utiliser cette machine que comme décrit dans le présent manuel. N'utiliser que les composants et les accessoires conseillés par le fabricant. Lorsque la machine ne fonctionnant pas correctement, a fait l'objet d'une chute ou d'une détérioration, a été laissée à l'extérieur, est tombée dans l'eau, la retourner au centre de service agréé. Ne pas opérer la machine lorsque les conduits de ventilation sont bloquées. Débarrasser les débris des conduits, car ils peuvent réduire l'écoulement d'air. Cette machine n'est pas adaptée au ramassage de poussières dangereuses Cette machine peut provoquer un incendie lorsqu'elle est utilisée près de vapeurs ou de matériaux inflammables. Ne pas l'utiliser près de liquides, de poussières ou de vapeurs inflammables. Cette machine est destinée à un usage commercial. Elle est recommandée davantage pour les domaines hôtelier, scolaire, hospitalier, industriel ou pour les bureaux, les chaînes de magasin, que pour un usage domestique normal. L'entretien et les réparations de la machine doivent être effectuées par un personnel qualifié. Si de la mousse ou du liquide sort de la machine, la mettre hors tension immédiatement. Déconnecter les batteries avant de nettoyer la machine ou de la soumettre à un entretien. Avant de se débarrasser de la machine, il est nécessaire de retirer les batteries et de les jeter correctement. S'assurer que toutes les plaques d'avertissement ou de précaution sont lisibles et fixées correctement sur la machine. Durant la manoeuvre de la machine, prendre garde aux personnes environnantes et notamment aux enfants. Avant l'utilisation de la machine, veiller à positionner tous les couvercles et portes comme indiqué dans les instructions. Lorsque la machine est laissée sans surveillance, s'assurer qu'elle ne se déplace pas de manière accidentelle. Cette machine ne doit être manoeuvrée que par un personnel expérimenté et qualifié. Lorsque la machine est laissée sans surveillance, la mettre hors tension ou verrouiller l'interrupteur principal afin d'empêcher un emploi non autorisé. Seuls les produits chimiques recommandés par le fabricant doivent être utilisés. Cette machine a été conçue pour être utilisée avec des brosses spécifiées par le fabricant. L'utilisation d'autres brosses peut affecter sa sûreté. N'employez pas sur des surfaces ayant un gradient de plus de 10% (6 degrés). CONSERVER CES INSTRUCTIONS 6 86395370 Operator Manual - Chariot 3 iScrub 26 Safety The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY. The level of hazard intensity is determined by the following definitions: WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death. CAUTION - Hazards or unsafe practices which could result in minor personal injury or product or property damage. FOR SAFETY: To Identify actions which must be followed for safe operation of equipment. Report machine damage or faulty operation immediately. Do not use the machine if it is not in proper operating condition. Following is information that signals some potentially dangerous conditions to the operator or the equipment. Read this information carefully. Know when these conditions can exist. Locate all safety devices on the machine. Please take the necessary steps to train the machine operating personnel. FOR SAFETY: DO NOT OPERATE MACHINE: Unless Trained and Authorized. Unless Operation Guide is Read and understood. In Flammable or Explosive areas. In areas with possible falling objects. WHEN SERVICING MACHINE: Avoid moving parts. Do not wear loose clothing; jackets, shirts, or sleeves when working on the machine. Use Kärcher North America approved replacement parts. Batteries emit hydrogen gas. Explosion or fire can result. Keep sparks and open flame away. Keep battery compartment open during charging. Keep sparks and flames away from the batteries. Do not smoke around batteries. Disconnect batteries before working on machine. Only qualified personnel should work inside machine. Always wear eye protection and protective clothing when working on or near batteries. Avoid skin contact with the acid contained in the batteries. Never allow metal to lie across battery tops. 86395370 Operator Manual - Chariot 3 iScrub 26 7 Safety Les symboles ci-dessous sont utilisés à travers ce manuel comme illustré dans leurs descriptions: DEGRÉS DE RISQUES EN CAS DE DANGER Il existe trois degrés de risques identifiés par les termes signalétiques -AVERTISSEMENT et ATTENTION et POUR VOTRE SÉCURITÉ. Le degré de risque est défini de la manière suivante: AVERTISSEMENT - Dangers ou méthodes dangereuses qui POURRAIENT provoquer de graves blessures ou entraîner la mort. ATTENTION - Dangers ou méthodes dangereuses qui pourraient provoquer des blessures légères ou une détérioration du produit ou des biens immobiliers. POUR VOTRE SÉCURITÉ: ce signe permet d'identifier les mesures de précaution à prendre pour assurer un bon fonctionnement du matériel. Rendre compte immédiatement d'une défaillance ou d'une détérioration de la machine. Ne pas utiliser la machine si celle-ci ne fonctionne pas correctement. Lire soigneusement les informations ci-dessous signalant certains dangers potentiels pour l'opérateur de la machine. L'opérateur doit être absolument au courant de ces dangers potentiels. Localiser tous les dispositifs de sécurité sur la machine. Il est conseillé de prendre les mesures nécessaires pour former le personnel opérateur. POUR VOTRE SÉCURITÉ: NE PAS MANOEUVRER LA MACHINE: Lorsqu'on n'est pas expérimenté ou qualifié. Lorsque le guide d'utilisation n'est pas été lu ou compris. Dans des zones inflammables ou explosives. Dans des zones où des objets peuvent tomber. LORS DE L'ENTRETIEN DE LA MACHINE: Éviter les parties amovibles. Ne pas porter de vêtements amples, tels que des vestes, des chemises ou des vêtements avec manches lors de l'utilisation de la machine. Utiliser les pièces détachées Kärcher North America homologuées. Les batteries émettent le gaz d'hydrogène. L'explosion ou le feu peut résulter. Étincelles de subsistance et flamme nue loin. Compartiment de batterie de subsistance ouvert en chargeant. Étincelles et flammes de subsistance loin des batteries. Ne fumez pas autour des batteries. Déconnecter les batteries avant de travailler sur la machine. La machine ne doit être confiée qu'à un personnel qualifié. Porter systématiquement des lunettes et des vêtements de protection lors d'une intervention sur les batteries ou aux alentours. Éviter tout contact de la peau avec l'acide contenu dans les batteries. Ne jamais placer d'objets métalliques sur le dessus des batteries. 8 86395370 Operator Manual - Chariot 3 iScrub 26 Safety Safety Label Locations These drawings indicate the location of safety labels on the machine. If at any time the labels become illegible, promptly replace them. EMPLACEMENT DE L'ÉTIQUETTE DE SÉCURITÉ REMARQUE : Ces dessins indiquent l'emplacement des étiquettes de sécurité sur la machine. Si, à tout moment, les étiquettes deviennent illisibles, contactez votre représentant autorisé pour un remplacement rapid 86244300 WARNING LABEL 86244310 CAUTION LABEL 86335010 86392960 OBC CAUTION 86252520 BATTERY CAUTION 86335010 86395370 Operator Manual - Chariot 3 iScrub 26 9 Operations Technical Specifications ITEM Nominal power Rated Voltage Rated Amperage Batteries Battery Compartment Dimensions Scrub Brush Motors - Disk Machine Scrub Brush Motors - Cylindrical Machine Vacuum Motor(s) Maximum flow rate of vacuum motor Maximum suction of vacuum motor Propelling Motor Mass (GVW) Weight empty without batteries Solution Control Solution capacity Recovery capacity Scrub brush diameter - Disk Machine Scrub brush diameter - Cylindrical Machine Scrub brush pressure Scrub brush pressure - Cylindrical Machine Scrub brush speed - Disk Machine Scrub brush speed - Cylindrical Machine Tires Foundation Pressure Maximum Speed Frame Construction Brake Minimum aisle u-turn width Maximum rated climb and descent angle Sound Pressure Level 10 DIMENSION/CAPACITY 1800 W 36 Volts DC 50 amps 3 X12 Volt 205-234 AH @ 20 hr. rate 21 in. x 16 in. x 17 in. tall (533mm x 406mm x 432mm) 2 x.5 HP (350 W) 2 x .75 HP (560W) .63 HP (470 W) 72 cfm (33.98 liters per second) 47.3 inches of water (11.7 kPa) 0.8 HP (600 W) 36V DC motor 1274 lbs (578 kg) 420 lbs (191 kg) Variable with automatic shut-off in neutral 25 gal (95 L) 27 gal (102 L) 13 inch (330 mm) 4.1 inch (105 mm) 0 -150lbs (0-667N) 0 - 44 lbs 300 rpm 720 - 950 rpm 10 in. (254mm) Solid scrubber compound rear, urethane front 135 psi (928 Kpa) 4.1 miles/hour (6.5 Km/hour) Powder coated steel Electrical parking brake,sets automatically whenever operator steps off platform or engages emergency stop. 60 in. (1524 mm) 10% (6 degrees) 66 dBA 86395370 Operator Manual - Chariot 3 iScrub 26 Operations ITEM MEASURE 50.0 inches (1270 mm) 56.1 inches (1425 mm) 29.5 inches (749 mm) 32.7 inches (830 mm) 33.5 inches (850 mm) 26 inches (660mm) Height Length Width without squeegee Width of squeegee - Disk Machine Width of squeegee - Cylindrical Machine Width of scrub path LENGTH WIDTH HEIGHT This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Cet appareil n'est pas prévu à l'usage des personnes (enfants y compris) avec des possibilités physiques, sensorielles ou mentales réduites, ou le manque d'expérience et de connaissance, à moins qu'ils aient été donnés la surveillance ou l'instruction au sujet de l'utilisation de l'appareil par une personne chargée de leur sûreté. Des enfants devraient être dirigés pour s'assurer qu'ils ne jouent pas avec l'appareil. 86395370 Operator Manual - Chariot 3 iScrub 26 11 Operations How This Machine Works The Chariot® is a battery powered, self-propelled, hard floor scrubber intended for commercial use. The appliance applies a cleaning solution onto a hard floor, scrubs the floor with brushes, and then vacuums the soiled water back into the recovery tank. The machine's primary systems are the solution system, scrub system, recovery system, and operator control system. The function of the solution system is to store cleaning solution and deliver it to the scrub system. The solution system consists of the solution tank, strainer, valve and an optional chemical metering pump and reservoir are available. The solution tank stores cleaning solution (water and detergent) until it is delivered to the scrub system. The strainer protects the valve from debris. The valve automatically prevents solution flow unless the scrub brushes are turned on and the machine is being propelled. The function of the scrub system is to scrub the floor. The disk scrub system consists of two rotary type disk scrub brushes, motors, scrub deck skirt and lift actuator. The brushes scrub the floor as the motors drive the brushes. The brush drive hubs allow the scrub brushes to follow irregularities and changes in the floor without loosing contact with the floor. The scrub deck skirt controls the cleaning solution on the floor so that the squeegee can pick it up. 12 The function of the recovery system is to vacuum the soiled water back into the recovery tank. The recovery system consists of the squeegee, vacuum motor, float ball filter, recovery tank. The squeegee wipes the dirty solution off the floor as the machine moves forward. The vacuum motor provides suction to draw the dirty solution off the floor and into the recovery tank. The float ball filter protects the vacuum fan from debris and shuts off suction to the tank when tank is full. The recovery tank stores the dirty solution. The function of the operator control system is to control the direction and speed of the machine. The directional control system consists of the direction control drive reset switch, throttle pedal, emergency stop/brake switch, steering wheel, propel controller, and drive wheel. The directional control drive reset switch signals forward or reverse direction and makes sure the operator is on platform before machine will propel. The controller interprets signals from the throttle pedal to command the drive wheel to propel or slow the machine. The steering wheel points the drive wheel in the direction desired by the operator. The parking brake automatically engages when the operator steps off the platform. The emergency stop/brake can be used to hold the machine on slopes. 86395370 Operator Manual - Chariot 3 iScrub 26 Operations 2 7 1 11 3 5 6 8 4 10 9 12 Components 7. Recovery Sight Dome 1. Control Panel-Drive 8. Solution Drain Hose 2. Control Panel-Scrub 9. Scrub Deck Aqua-Mizer™ 3. Console 10. Scrub Deck Skirt 4. Pedal Platform 11. Recovery Lid 5. Rear Cover 12. Recovery Drain Hose 6. Tank 86395370 Operator Manual - Chariot 3 iScrub 26 13 Operations 8 9 5 2 3 7 1 6 4 14 86395370 Operator Manual - Chariot 3 iScrub 26 Operations Drive Controls 1. Key Switch 2. Emergency Stop/Brake Switch 3. Directional Control / Drive Reset Switch 4. Throttle Pedal 5. Horn Button 6. Steering Wheel 7. Speed Control 8. Battery Discharge Indicator 9. Hour Meter 1. KEY SWITCH Controls the power for machine functions. To turn the machine power on, rotate key clockwise. To turn the machine off, rotate key counterclockwise. When the key is turned on the battery symbol will flash while the system runs self-diagnostics and returns scrub deck and squeegee to their raised positions, if necessary. The controller will not respond to other commands until this routine is complete. 2. EMERGENCY STOP/BRAKE SWITCH This safety feature is designed to cut all power to the machine at any time and apply parking brake. To shut the machine power off, push the Emergency Stop Switch, this will also engage the parking brake and cause the machine to stop immediately. Excessive emergency stop usage can cause premature brake wear; use only when necessary. To reset the machine, rotate the switch clockwise. 3. DIRECTIONAL CONTROL / DRIVE RESET SWITCH This safety feature is designed to ensure safe engagement of propel drive. Each time the machine power is turned on, or each time an operator steps on to the platform, the Drive Reset Switch must be pushed before machine will propel. Controls the direction of travel of the vehicle. The lit arrow on the switch indicates direction of travel. To travel forward, press the top of the switch. To travel in reverse, press the bottom of the switch. 86395370 Operator Manual - Chariot 3 iScrub 26 15 Operations 4. THROTTLE PEDAL Controls the speed of the vehicle within the speed control setting selected. Pressing the pedal causes the machine to travel in the direction selected by the Directional Control Switch. To increase speed, increase pressure on the pedal. To decrease speed, decrease pressure on the pedal. 5. HORN BUTTON The horn is activated by pressing the horn button. 6. STEERING WHEEL The steering wheel turns the front wheel causing the machine to change direction. 7. SPEED CONTROL Controls the maximum speed of the machine. There are two transport settings, slow and fast. To change speed, rotate the dial to either slow or fast position. The speed for fast and slow are as indicated on the control panel by the symbols shown below.The throttle pedal will always regulate the speed between 0 and maximum. 16 86395370 Operator Manual - Chariot 3 iScrub 26 Operations 8. BATTERY CHARGE LEVEL INDICATOR Indicates the charge level of the batteries. The meter display is divided into 10 bars. Bars illuminated on the far right indicate full charge. Bars flashing near the left side indicate the batteries should be recharged. Further operation of the machine could damage the machine or the batteries. When the machine is left overnight with less than a full charge, the display may initially indicate a full charge. It will also indicate a full charge if the batteries are disconnected, then reconnected. After a few minutes of operation the meter will give the correct charge level. 9. HOUR METER Records the number of hours the machine has been in scrubbing operation. This information is useful in determining when to service the machine. 86395370 Operator Manual - Chariot 3 iScrub 26 17 Operations Scrub Controls 2 1 1. Function Mode Dial The first two positions are for transport only. See drive controls section. Daytime cleaning / light cleaning This mode is used for light cleaning. In this mode the machine will propel at a maximum of medium speed. The scrub deck will automatically lower to a lower down pressure setting. The water will flow at a low rate. Water will automatically shut off in neutral and restart when pressure resumes. The squeegee will automatically lower and vacuum will flow at a slow rate. (Squeegee will continue to lower and the vacuum will continue to run in neutral. The squeegee will raise in reverse.) Daytime Plus cleaning / light cleaning This mode is used for light cleaning. In this mode the machine will propel at a maximum of medium speed. The scrub deck will automatically lower to a lower down pressure setting. The water will flow at a low rate. Water will automatically shut off in neutral and restart when pressure resumes. The squeegee will automatically lower and vacuum will flow at a medium rate. Medium scrub level cleaning This mode is used for medium level cleaning. In this mode the machine will propel at a maximum of medium. The scrub deck will lower at a medium down pressure. The water will flow at a medium rate. The vacuum will flow at a medium rate. 18 86395370 Operator Manual - Chariot 3 iScrub 26 Operations Heavy scrub level cleaning This mode is used for heavy level cleaning. In this mode the machine will propel at a maximum of slow speed. The scrub deck will lower to a heavy down pressure. The water will flow at a high rate. The vacuum will flow at a high rate. Vacuum only mode This mode is used for picking up solution only. The brushes and water will both be up and off. In this mode the machine will propel at a maximum of slow speed. The squeegee will automatically lower and the vacuum will flow at a high rate. The squeegee will raise in reverse. The squeegee and vacuum will remain down and on in neutral propel. Double Scrub cleaning This mode is used for putting down solution and scrubbing without picking it back up. In this mode the machine will propel at a maximum speed of slow. The scrub deck will automatically lower to a heavy scrub level. The solution will flow at a high rate. The brushes and water will shut off and raise when the machine is in neutral. They will resume when propelling is resumed. 2. Solution Button and Indicator The button enables and disables solution flow. When the green indicator is illuminated, solution flow is enabled. 86395370 Operator Manual - Chariot 3 iScrub 26 19 Operations Machine Operation Filling Solution Tank Pre-Run Machine Inspection Do a pre-run inspection to find possible problems that could cause poor performance or lost time from breakdown. Follow the same procedure each time to avoid missing steps. NOTE: Perform Pre-run Machine Check before operating machine listed in Service Schedule in Maintenance Section. Starting Machine FOR SAFETY: Before starting machine, make sure that all safety devices are in place and operating properly. 1. The operator should be on the pedal platform. The throttle pedal must be in the neutral position. 2. Turn the machine power on by turning key switch clockwise to the "ON" position. 3. Press the Drive Reset Directional Control Switch to reset and set the intended direction for travel. 4. Press lightly on the throttle pedal with right foot. FOR SAFETY: Before leaving or servicing machine; stop on level surface, turn off machine and remove key. 1. Turn the machine power off. 2. Remove solution cover. 3. Fill the solution tank with clean water, leaving enough room for the required amount of detergent. The solution tank capacity filled to fill inlet is 25 gallons (95 liters). The water must not be hotter than 140° F (60°C) to prevent damage to the tank. 4. Measure the chemical into the solution tank. The solution cover is also a 2 oz. (60 ml) measuring cup. Liquid chemicals should be added to the solution tank after filling with water. Dry chemicals should be thoroughly mixed before being added into solution tank. Commercially available, high alkaline floor cleaners, are suitable for use in the solution system. NOTE: Read the chemical manufacturers recommended proportion instructions. 5. Replace solution tank cover. Emergency Stop Procedures 1. Push in emergency stop button. This will also engage the parking brake and cause the machine to stop immediately. Flammable materials can cause an explosion or fire. Do not use flammable materials in the tanks. Les matières inflammables peuvent provoquer une explosion ou un incendie. Ne pas utiliser de matériaux inflammables dans les réservoirs. 20 86395370 Operator Manual - Chariot 3 iScrub 26 Operations Optional Chemical Metering System 1. Fill chemical container and place into console recess. Attach lid. 2. Open rear cover and turn chemical selection knob to chemical manufacturers recommended dilution. 3. Press and hold prime button for 30 seconds or until chemical has filled line to scrub deck. If the machine is allowed to stand in neutral with the scrub deck down, the solutions flow stops and brush motors stop. If either forward or reverse travel is selected, the solution flow will continue in the same setting and the scrub brush motors will continue in their same setting once movement of machine begins. Overlap the brush path and avoid transporting over previously cleaned areas. Normal Scrubbing Plan the scrubbing pattern in advance. The longest track is around the perimeter of the area to be cleaned. For efficient operation, the runs should be the longest possible without turning, stopping, or raising or lowering scrub deck/squeegee. In order to achieve the best possible results, the area which is to be cleaned should be swept before scrubbing. Large debris, strings and wire must be removed to prevent being caught in brushes or squeegee. 86395370 Operator Manual - Chariot 3 iScrub 26 21 Operations To Begin Scrubbing When operating the machine around people, pay close attention for unexpected movement. Use extra caution around children. NOTE: The solution flow can be adjusted up or down approximately 10 percent by changing the dip switch settings on the control board. The dip switches are located on the left side of the control board, mounted on the lower control panel. NOMINAL 2 1 Lorsque vous utilisez la machine en présence de gens, portez une attention particulière aux mouvements inattendus. Soyez plus prudent, surtout en présence d’enfants. OFF OFF + 20% 1 ON - 20% 2 OFF 2 1 OFF ON To Stop Scrubbing Flammable liquids and/or reactive metals can cause explosions or fire! Do not pick up. Les liquides inflammables et / ou les métaux réactifs peuvent provoquer des explosions ou un incendie! Ne les ramassez pas. 1. Stand on the operator platform. Throttle pedal must be in neutral position. 2. Turn machine power on. 1. Rotate the function knob to either transport position. The brush motors will stop and the scrub deck will rise to the park position. After 10 seconds the squeegee will raise, and 10 seconds later the vacuum motor will turn off. This delay is to clear the vacuum hose of recovered solution. 2. Allow the throttle pedal to return to neutral. 3. Turn machine power off. FOR SAFETY: Before leaving or servicing machine: stop on level surface, turn off machine and remove key. 3. Press the Drive Reset / Directional Control Switch, selecting the desired travel direction. Double Scrub 4. Position the function control knob to the desired operation. The scrub deck and squeegee will lower, and the vacuum will turn on. For floors which are heavily soiled or have thick accumulations of floor finish, may not clean sufficiently with one pass. In these cases it may be necessary to double scrub. 5. Drive machine forward to begin scrubbing. The scrub brush motors will run and solution will flow when the throttle is depressed. Rotate the knob to the double scrub position. Make the first pass over the surface being cleaned with NOTE: Shut machine off immediately if water or foam is expelled from the machine. NOTE: Solution flow is automatically shut off when brush motors stop. When brush motors are activated, flow automatically resumes. 22 the squeegee up, vacuum off and the solution on. For best results also remove the Aqua-mizer™, this will allow the solution to stay in contact with the soil while loosening the surface accumulation with the brushes. Allow time for the first application to stay in contact with the floor. Length of time between the first and second pass depends on amount of accumulation and the type of chemical being used. A second scrubbing with the function knob in one of the normal scrubbing modes will lower the squeegee and will keep the solution on and 86395370 Operator Manual - Chariot 3 iScrub 26 Operations brushes down to further loosen soil. The additional application of solution will further assist the difficult cleaning job. FOR SAFETY: When using machine, go slow on inclines and slippery services. Solution Tank 1. Remove the recovery tank lid. 2. Pull the solution drain hose from its mounting pocket. Unscrew the cap, then lower hose in direction of drain. 3. Remove the solution tank cap. 4. Flush the solution tank out with clean water and run several gallons of clean water through systems. Do not use water hotter than 140°F (60°C) to clean tank. Damage may occur. Recovery Tank Lid 5. If machine is to be stored, leave solution cap off. NOTE: Never allow solution to remain in tank. Damage to tank, seals and valves could occur. Optional Chemical Metering System 1. Remove chemical container from machine and store unused chemical. Flush chemical container with water. Recovery Drain Hose Solution Drain Hose 2. Fill chemical container partway with clean water. Press and hold prime button for 1 minute. 3. Empty chemical container. press and hold prime button for 30 seconds to purge chemical lines. Emptying and Cleaning Tanks Chemical Metering Controls 1. Park the machine next to a floor drain. Drain hoses are at the front of the machine. 1. CHEMICAL METERING SYSTEM SELECTION DIAL (OPTIONAL) 2. Turn the machine power off. Recovery Tank 1. Open the recovery tank lid. Pull the recovery drain hose from the mounting bracket. Open cap, then lower hose in direction of the drain. Do not stand in front of end of hose. Recovered solution will come out with force. 2. Flush the recovery tank out with clean water. Do not use water hotter than 140°F (60°C) to clean tank. Damage may occur. Eight position dial which controls chemical system operation. Upper five positions turn chemical system on and controls dilution from .5 to 4.0 oz/ gal. Three lower positions turn chemical system off. 2. CHEMICAL METERING SYSTEM PRIME BUTTON (OPTIONAL) Runs chemical pump when pressed. Press for 30 seconds to prime empty chemical system. Fill chemical reservoir with clean water and press prime button for one minute to flush chemical system. 3. Clean debris bin. 4. Clean off the float shut-off system and inspect for free movement of float. 5. Replace the drain hose cap and secure drain hose. 6. If machine is to be stored, leave the recovery tank lid propped open. 86395370 Operator Manual - Chariot 3 iScrub 26 23 Operations Squeegee Disk 3 2 1 1. Squeegee Handle The squeegee handle holds the squeegee in place. 2. Squeegee Hose and Tube The squeegee hose and tube carry the recovered solution to the recovery tank. 3. Squeegee Wheels The squeegee wheels support the squeegee at the correct height and angle to automatically obtain optimum suction. The squeegee requires no adjustment. 24 86395370 Operator Manual - Chariot 3 iScrub 26 Operations Squeegee - Cylindrical 3 1 2 1. Squeegee Knobs The squeegee knobs hold the squeegee in place. 2. Squeegee Hose and Tube The squeegee hose and tube carry the recovered solution to the recovery tank. 3. Squeegee Wheels The squeegee wheels support the squeegee. The height can be adjusted by turning the knobs. 86395370 Operator Manual - Chariot 3 iScrub 26 25 Notes 26 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance Service Schedule MAINTENANCE Check water level of batteries after charging; add distilled water if necessary. (Wet cell only) Check that recovery lid seals tightly. Visually check for damaged or worn wheels. Check brushes or pads for proper installation. Check vacuum hose connections. Check that squeegee is securely attached. Check for securely attached drain hoses, plug and cap. Check pedal, brake and steering for proper operation. Clean out recovery tank and debris bin. Clean and inspect float shutoff. Clean out solution tank. Clean and inspect solution filter strainer. Run vacuum motors to dry. Clean brushes or pads and check wear. Clean squeegee blades and check wear. Clean outside of tanks, check for damage. Store with recovery lid propped open. Charge batteries if needed. Flush chemical system (if equipped). Clean off top of batteries. Check battery cells with hydrometer. (Wet cell only) Inspect scrub deck skirts and Aqua-Mizers. Check battery connections are tight. Clean battery cases and battery compartment. Check parking brake. Clean cables and pulleys for squeegee lift. Clean pivot points on squeegee and scrub deck. Check all motors for carbon brush wear. Check motor commutators. Check steering chain tension. Check chemical pump peristaltic tube BEFORE EACH WORK PERIOD AFTER EACH 50 100 200 WORK PERIOD HRS HRS HRS * * * * * * * * 86395370 Operator Manual - Chariot 3 iScrub 26 * * * * * * * * * * * * * * * * * * * * * * * 27 Maintenance 1 2 3 4 5 7 6 Batteries 1. Rear Cover Latch 2. Rear Cover 3. Battery Connector-Machine 4. Battery Connector-Battery 5. Batteries 6. Battery Tray Liner 7. Battery Tray 28 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance Batteries (Wet Cell Only) The batteries provide the power to operate the machine. The batteries require regular maintenance to keep them operating at peak efficiency. The machine batteries will hold their charge for long periods of time, but they can only be charged a certain number of times. To get the greatest life from the batteries, charge them when their charge level reaches 25% of a full charge. Use a hydrometer to check the charge level. Do not allow the batteries to remain in a discharged condition for any length of time. Never expose a discharged battery to temperatures below freezing. Discharged batteries will freeze causing cracked cases. Do not operate the machine if the batteries are in poor condition or if they have a charge level below 25% (specific gravity below 1.155). Keep all metallic objects off the top of the batteries, as they may cause a short circuit. Replace worn or damaged cables and terminals. Check the electrolyte level in each battery cell before and after charging the batteries. Never add acid to the batteries, use distilled water. Do not allow water level to fall below the battery plates. Portions of plates exposed to air will be destroyed. Do not overfill. Keep plugs firmly in place at all times. When servicing machine, avoid contact with battery acid. Lors de l'entretien de la machine, évitez tout contact avec l'acide de batterie. Batteries emit hydrogen gas. Explosion or fire can result. Keep sparks and open flame away. Keep covers open when charging. Les batteries émettent du gaz hydrogène. Une explosion ou un incendie peut en résulter. Maintenez les étincelles et les flammes nues à l’écart. Gardez les carters ouverts lors du chargement. Wear eye protection and protective clothing when working with batteries. Portez des lunettes de protection et des vêtements de protection lorsque vous travaillez avec des batteries. Charge batteries in a well ventilated area. Chargez les batteries dans un endroit bien ventilé. Battery Maintenance 1. When cleaning the batteries, use a solution of baking soda and water. Do not allow the cleaning fluid to enter the battery cells, electrolyte will be neutralized. 2. Maintain the proper electrolyte level in each battery cell. If a cell should accidentally overflow, clean immediately. 3. Wipe off the top of the batteries at least once a week. 4. Test battery condition with a hydrometer at least once a week. 5. Ensure that all connections are tight and all corrosion removed. 6. Every 4 to 6 months, remove that batteries from the machine and clean the battery cases and battery compartment. Not all batteries require maintenance. AGM batteries are maintenance free. Do not attempt to remove sealed caps from AGM batteries. Warranty is void if caps are removed from AGM battery. L’entretien n’est pas nécessaire pour toutes les batteries. Les batteries AGM ne nécessitent pas d’entretien. N'essayez pas d'enlever les bouchons scellés des batteries AGM. La garantie est annulée si les bouchons sont retirés des batteries AGM. 86395370 Operator Manual - Chariot 3 iScrub 26 29 Maintenance Checking Battery Specific Gravity Charging Batteries Use a hydrometer to check the battery specific gravity. When servicing machine, avoid contact with battery acid. Lors de l'entretien de la machine, évitez tout contact avec l'acide de batterie. Batteries emit hydrogen gas. Explosion or fire can result. Keep sparks and open flame away. Keep covers open when charging. CHECKING GRAVITY a. Hydrometer Battery b. Battery NOTE: Do not take readings immediately after adding distilled water, if the water and acid are not thoroughly mixed, the reading may not be accurate. Les batteries émettent du gaz hydrogène. Une explosion ou un incendie peut en résulter. Maintenez les étincelles et les flammes nues à l’écart. Gardez les carters ouverts lors du chargement. Check the hydrometer readings against this chart. SPECIFIC GRAVITY @ 80 F (27C) 1.265 1.225 1.190 1.155 1.120 BATTERY CONDITION 100% CHARGED 75% CHARGED 50% CHARGED 25% CHARGED DISCHARGED NOTE: If the readings are taken when the battery electrolyte is any temperature other than 80°F (27°C), the reading must be temperature corrected. To find the corrected specific gravity reading when the temperature of the battery electrolyte is other than 80°F (27°C): Add (+) to the specific gravity reading 0.004 (4 points), for each 10°F (6°C) above 80° (27°C). Subtract (-) from the specific reading 0.004 (4 points), for each 10°F (6°C) below 80°F (27°C). Wear eye protection and protective clothing when working with batteries. Portez des lunettes de protection et des vêtements de protection lorsque vous travaillez avec des batteries. Charge batteries in a well ventilated area. Chargez les batteries dans un endroit bien ventilé. Switch main circuit breaker off before charging. 30 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance Use a 36 volt, 20 amp maximum output DC charger which will automatically shut off when the batteries are fully charged. 1. Stop the machine in a clean, well ventilated area next to the charger. 2. Turn “OFF” machine. FOR SAFETY: Before leaving or servicing machine; stop on level surface, turn off machine and remove key. 3. Open rear cover, unplug batteries from machine, unlatch battery tray and pull out to expose batteries. Batteries emit hydrogen gas. Explosion or fire can result. Keep sparks and open flame away. Keep covers open when charging. FOR SAFETY: When charging, connect the charger to the batteries before connecting the charger to the AC wall outlet. Never connect the charger to the AC wall outlet first. Hazardous sparks may result. 6. Plug the charger connector into the battery connector. Connect the charger AC plug to a wall outlet. The charger gauge should indicate that the batteries are charging. 7. When the batteries are fully charged, disconnect the charger from the AC wall outlet, then disconnect the charger from the batteries. 8. Connect the batteries to the machine connector. 9. Check the electrolyte level. It should be up to the indicator ring. If necessary, add distilled water. 10. Close the rear cover. Les batteries émettent du gaz hydrogène. Une explosion ou un incendie peut en résulter. Maintenez les étincelles et les flammes nues à l’écart. Gardez les carters ouverts lors du chargement. 4. Check the electrolyte level in each battery cell. Before charging, add just enough distilled water to cover the plates. After charging is complete, add just enough distilled water to bring up the level to the indicator ring. If the water level is too high before charging, normal expansion rate of the electrolyte may cause an overflow resulting in a loss of battery acid balance and damage the machine. 5. Replace the battery caps, and leave them in place while charging. 86395370 Operator Manual - Chariot 3 iScrub 26 31 Maintenance Changing Batteries Stop the machine in a clean area next to the charger. Turn off machine. FOR SAFETY: Before leaving or servicing the machine; stop on level surface, turn off machine and remove key. 1. Remove the rear cover. 2. Disconnect battery pack from machine. 3. Unlatch battery tray from machine and pull out to expose batteries. 4. Use the proper size open end wrench to disconnect main ground wire first and secure cable terminal away from batteries. 5. Disconnect main positive lead and secure cable terminals away from batteries. 6. Loosen both terminals on each jumper cable and remove one at a time. 7. Prepare a suitable site to place the batteries. Attach suitable battery lifting device and lift batteries from the machine. Batteries are a potential environmental hazard. Consult your battery supplier for safe disposal methods. Fixez le dispositif de levage de batterie approprié et levez les batteries de la machine. Les batteries constituent un danger potentiel pour l'environnement. Consultez le fournisseur de votre batterie pour connaître les méthodes d'élimination sûres. RED + BLK - RED + BLK - RED + BLK - REAR OF MACHINE 32 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance Onboard Charger (Optional) Circuit Breaker must be off before unplugging batteries. Onboard Charger Programming For machines equipped with optional on-board charger. When replacing batteries, charger programming changes may be required. If replacing batteries with same type, (e.g. maintenance free batteries with maintenance free) no programming is required. When batteries with different type (e.g.maintenance free with wet cell), programming change are required. Failure to make programming changes may lead to reduced battery life. 1. Remove upper control panel. 2. Peel back label on charger to access dip switches. 3. Change switches to correct battery type. DIP DIP DIP DIP DIP DIP DIP DIP 2 3 4 5 6 7 8 1 LEAD ACID OFF ON ON ON OFF ON ON OFF DISCOVER AGM ON OFF OFF OFF OFF ON ON OFF 4. Replace charger label and install upper control panel. 86395370 Operator Manual - Chariot 3 iScrub 26 33 Maintenance 2 1 Squeegee - Disk 1. Squeegee 2. Squeegee Retainer Knob 2 1 Squeegee - Cylindrical 1. Squeegee 2. Squeegee Retainer Knob 34 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance Squeegee Blades The front squeegee blade allows solution to pass through channels in the blade into the squeegee assembly while maintaining vacuum to provide lift. The front blade has four wear surfaces and can be rotated for extended life. The front blade should not require regular replacement under normal use. The squeegee is self adjusting. The rear blade wipes the floor to a near dry condition. It is important the rear blade be in good condition to properly do its job. As with the front, each squeegee blade assembly has four wear surfaces for extended service. Check both the front and rear squeegee blades for damage and wear each day in the pre-run check. Change the front blade if it is torn or has an uneven edge. Change the rear blade if it is less than half the original thickness. To Remove Squeegee Assembly FOR SAFETY: Before leaving or servicing machine; stop on level surface, turn off machine and remove key. 1. With the squeegee in the up position, turn key switch "OFF". 2. Disconnect vacuum hose from squeegee and loosen retainer knob on left side of squeegee lifting carrier. 3. Pull squeegee assembly from the lifting carrier. 4. Inspect or repair as necessary and reinstall. To Replace or Rotate Squeegee Blades Disk 1. With the squeegee in the up position, turn key switch "OFF". 2. Remove the squeegee assembly from the machine. 3. Unscrew each of the four knobs until they are nearly removed from the squeegee assembly. Grasp the squeegee assembly and push on the knobs to remove the blade retention plate. Remove the knobs and pull the retention plate out. 4. Remove blades from squeegee housing. Rotate the squeegee blade to a new edge position or replace as required. Each blade has four new edge positions. 5. Install the blades in the squeegee housing by hooking blades on retention features. 6. Install blade retention plate in squeegee housing and assemble knobs. To Replace or Rotate Squeegee Blades Cylindrical 1. With the squeegee in the up position, turn key switch "OFF". 2. Remove end-cap from squeegee assembly. 3. Pull blades out of Squeegee. 4. Rotate or Replace squeegee blades and insert into squeegee assembly. 5. Replace end-cap on squeegee assembly. 86395370 Operator Manual - Chariot 3 iScrub 26 35 Maintenance 2 1 6 3 4 5 Scrub Deck - Disk 1. Scrub Deck Aqua-mizer™ 4. Scrub Deck Skirt Brush Strip 2. Aqua-mizer™ Retainer Knob 5. Scrub Brush Motor 3. Scrub Deck Skirt 6. Scrub Deck Lift Actuator 36 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance Scrub Brushes There are four different types of brushes available to cover applications from cleaning heavily soiled floors to polishing. A pad driver is also available to take advantage of the many cleaning pads on the market. Please refer to the following to assist in selecting the proper brush or pad for the work at hand. Uncoated Floors Aggressive Grit is a nylon fiber impregnated with silicone carbide grit. It grinds away stain, soil, and removes surface material. Mild Grit is a less aggressive silicone carbide grit suitable for cleaning medium soil conditions. Advantages are faster ground speed than nylon bristles on light solid applications. Polypropylene is a general-purpose scrub brush with stiff bristles. Polypropylene works well for maintaining concrete, wood and tile floors. Finished Floors Nylon bristles are used in a variety of applications on coated or uncoated surfaces. White Pads (Polishing) are used for dry polishing to achieve a high-gloss appearance, or surface washing on highly polished or burnished floors. Red Pads (Buffing) are used for light-duty scrubbing. When used with a mild detergent they will provide surface cleaning without removing the finish. Blue Pads (Scrubbing) are used for heavy-duty scrubbing and light stripping. The blue pads remove less finish than brown stripping pads, yet will remove black marks, stains and dirt. Black Pads (Stripping) are used for easy and complete removal of old floor waxes/finishes. They will quickly remove ground in dirt, black heel marks, and spills. When used with the proper stripper, this pad leaves the floor clean and ready for finishing. The scrub brushes should be checked before each days work for wire, string, wear and damage. 86395370 Operator Manual - Chariot 3 iScrub 26 37 Maintenance Replacing or Installing Scrub Brushes Disk NOTE: Damage to driver or brush could occur if not securely attached. FOR SAFETY: Before leaving or servicing the machine; stop on level surface, turn OFF machine and remove key. 1. Turn machine power off. 2. Open access cover on deck shroud. 3. Locate release lever, press release lever towards front of machine to release brush pad. The pad will drop down when released. Lift deck shroud up and slide brush/pad assembly out. 4. Remove brush/pad from holder and replace with new brush/pad. 5. To reinstall, lift deck shroud upward as shown. Center the brush/pad driver under the brush drive hub. Raise brush/pad until it contacts brush driver assembly. Turn clockwise until release lever plate locks into position. 6. Check that release lever/plate is completely closed and pad/brush is securely attached. 38 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance Brush Motor Carbon Brush Replacement Do not use a pressure washer to clean around the brush motors. Use tap pressure only. N’utilisez pas de nettoyeur haute pression pour nettoyer autour des moteurs des brosses. Utilisez seulement la pression du robinet. To Replace Scrub Brush Motors With the scrub deck in the raised position, disconnect brush motor wiring connector from harness. 1. Remove skirt from scrub deck. 2. Remove retaining bolt, lock washer, flat washer and star drive from brush motor shaft. 3. Remove 4 brush motor mounting bolts located under scrub deck. 4. Lower scrub deck. 5. Remove brush motor. 6. Reverse steps to install. 1. Scribe alignment mark on motor barrel to motor cap. Remove two bolts. 2. Remove end cap from motor. NOTE: Motors contain two wave washers in cap. Do not lose these. 3. Release brush from spring tension. Remove screw connecting brush wire lead to brush holder. Clean brush holder to insure free movement. 4. Retract spring and install new brush. Install connector screw and lead. 5. When all new brushes are installed. Place all in retracted position, held into brush holder by spring tension. 6. Carefully place end cap onto bearing on motor shaft. NOTE: Use care to assure wave washer alignment. 7. With end cap in partially installed position, release all brushes to contact position with motor commutator. NOTE: Failure to insure all brushes are released will result in motor failure. 8. Reset end cap and realign with scribe marks on motor barrel. Reinstall the two attach bolts from cap into base. Maintain alignment between motor barrel base and cap. 86395370 Operator Manual - Chariot 3 iScrub 26 39 Maintenance 1 2 3 Scrub Deck - Cylindrical 1. Scrub Deck Skirt 2. Debris Hopper 3. Scrub Deck Lift Actuator 40 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance Replacing or Installing Scrub Brushes Cylindrical 1. Turn machine function dial to transport mode, allowing deck to return to “up” position. Turn the machine power off. FOR SAFETY: Before leaving or servicing the machine; stop on level surface, turn OFF machine and remove key. 2. On right and left sides of deck, turn both brush and skirt releases 1/4 turn counter-clockwise. 3. Swing deck skirts out. Remove brush end caps. Slide brushes out the sides of deck. 4. To reinstall, slide brushes into deck. Replace brush end caps. Lift end cap up and turn brush release 1/4 turn clockwise, locking brush in place. Swing deck skirt back to deck. Turn skirt release 1/4 turn clockwise, locking skirt into place. NOTE: Check that brush end cap is properly secured into deck housing. Check that brush is suspended off ground while deck is in “up” position. 86395370 Operator Manual - Chariot 3 iScrub 26 41 Maintenance Actuator Scrub Deck Removal / Replacement Scrub Deck Actuator Adjustment FOR SAFETY: Before leaving or servicing machine, stop on a level surface. Turn off machine. To adjust the actuator: 1. Remove the two screws that secure actuator spring plate and pull actuator barrel from stud on actuator spring bracket. 1. While holding actuator barrel to prevent it from spinning, apply power to the actuator such that it is fully extended. Positive power to white wire, and negative/ground to black. Limit switch within actuator will stop it. 2. Remove clevis pin from upper bracket of actuator. 3. Disconnect actuator from wiring harness. 4. Reverse steps to install. The actuator will need to be adjusted when replaced. 2. Turn barrel out one or more full turns to assure that when it is retracted it will not bind against itself. 3. While holding actuator barrel to prevent it from spinning, apply power to the actuator such that it is fully retracted. Positive power to black wire, and negative/ground to white wire. Limit switch within actuator will stop it. 4. With actuator fully retracted, turn barrel in until it touches the base of the threaded shaft. 5. At the bottomed out position, turn the barrel one full turn, then enough more to allow connection to lift linkage. 6. Connect actuator to lift linkage. 7. Check travel of actuator during operation. 42 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance Circuit Protection 1 Circuit Breakers 1. MAIN CIRCUIT BREAKER Interrupts the flow of power from batteries in the event of an electrical overload. When the circuit breaker is tripped, it can be reset by pressing the toggle switch. If the circuit breaker continues to trip, the cause of the electrical overload must be corrected. 86395370 Operator Manual - Chariot 3 iScrub 26 43 Maintenance 4 2 6 1 5 3 Solution 1. Strainer 2. Solution Cap 3. Solenoid Valve 4. Chemical Bottle (Optional) 5. Chemical Pump (Optional) 6. Flow Meter (Optional) 44 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance Solution Strainer Located in bottom of tank. Protects system from debris. Solenoid Valve The solenoid valve is mounted on the front of the scrub deck, on left side. The solenoid valve opens and closes to meter the correct amount of solution to the scrub deck. The solenoid valve shuts off solution flow to scrub deck whenever scrubbing stops. To repair or replace solenoid valve, remove screws that secure it to deck. Chemical Bottle (Optional) Holds chemical for optional metering system. Chemical Pump (Optional) Located in front of operator platform on left side. Pump meters chemical into water flow from solution tank. Flow Meter (Optional) Located front left side of machine. Measure water flow being delivered to scrub deck for accurate chemical dilution. 86395370 Operator Manual - Chariot 3 iScrub 26 45 Maintenance 1 3 2 Vacuum 1. Recovery Tank Float Shut-off 2. Vacuum Motor 3. Debris Bin 46 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance Recovery Tank Float Shut-off When water is no longer being vacuumed from the floor and the vacuum fan is operating, the ball float has engaged. The vacuum motor will not vacuum water with recovery tank full. The recovery tank must be drained. 1. The float shut-off screen can be cleaned in or out of the machine. Vacuum Motor Carbon Brushes End Cap Carbon Brushes 2. To clean the float shut-off while it is inside the machine wipe material off screen then rinse. Check that the ball is also clean and moves freely. 3. To remove the float shut-off, tilt and pull the float screen assembly off the tank fitting barb. 4. To install, tilt and push the float screen assembly over the tank fitting barb. FOR SAFETY: Before leaving or servicing machine, stop on a level surface, turn off machine and disconnect power. To Repair or Replace Vacuum Motor 1. Remove rear cover from machine. 2. Remove upper control panel. If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center. Inportant: These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely. 3. Remove three screws on lower panel and hinge panel down. 4. Disconnect electrical connector from the vacuum motor. 5. From topside, remove one nut in front of vacuum motor. 3 [9.5mm] 8 Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less tan 3/8" (9.5mm) long. 6. From backside, support vacuum motor and remove two remaining nuts on vacuum housing. 7. Lower vacuum motor, remove front rubber isolator from stub. Pull vacuum motor and upper housing out of machine. Lower housing and hoses stay with machine. 8. Remove upper housing from vacuum motor by removing four screws. 9. Reverse steps to install. Make sure that gasket is on vacuum so that vacuum seals against tank. 86395370 Operator Manual - Chariot 3 iScrub 26 47 Maintenance Drive Motor 1. Drive Motor 2. Parking Brake 48 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance Electric Parking Brake Engagement FOR SAFETY: Before leaving or servicing machine, stop on a level surface, turn off machine and remove key. Electric Brake Engagement Drive Motor Carbon Brush Replacement Do not use a pressure washer to clean around the motors. Use tap pressure only. This machine is equipped with an electric parking brake. The brake automatically engages and keeps the machine from moving whenever the operator steps off the platform or when emergency stop is engaged. N’utilisez pas de nettoyeur haute pression pour nettoyer autour des moteurs des brosses. Utilisez seulement la pression du robinet. The brake has a mechanical over-ride that can be engaged so machine can be pushed or towed (slowly). FOR SAFETY: Before leaving or servicing machine, stop on a level surface, turn off machine and remove key. To disengage brake: 1. Disconnect batteries from machine. 2. Remove brush caps from motor housing. 3. Replace brushes. 4. Install brush caps to motor housing. 1. Pull lever away from brake housing. 2. Insert material to hold brake lever in place. Do not operate machine with brake disengaged. N'actionnez pas la machine avec le frein désengagé. 86395370 Operator Manual - Chariot 3 iScrub 26 49 Maintenance Transporting Preparation for Loading/Unloading Trailer Pushing Machine The machine may be pushed for short distances at speeds not to exceed 5 mph. Be careful to avoid damaging machine. The machine may be pushed by hand from the rear. NOTE: To avoid damage caused by regenerative voltage, disconnect traction motor before towing or pushing machine. Before loading or unloading machine from trailer, remove squeegee, scrub deck, side skirts or side squeegees, Aqua-Mizers and scrub brushes (pads) to eliminate interference with tie-downs. Scrub head must be in the up position before loading. When transporting the machine on a trailer or in a truck, in addition to using tie-downs, be sure to set the parking brake, and block the tires to prevent the machine from rolling Machine Tie-Downs There are four tie down points, two on the front wheel guards, and two on the rear axle located on either side of the foot box. Tie down point Wheel Guards (Both sides) 50 Tie down point Rear Axle (Both sides) 86395370 Operator Manual - Chariot 3 iScrub 26 Notes 86395370 Operator Manual - Chariot 3 iScrub 26 51 Maintenance Troubleshooting PROBLEM No power to machine Little or no propel CAUSE Battery disconnected Emergency shut-off activated Battery cables corroded Faulty key switch On board charger plugged in Main circuit breaker tripped Low battery charge Machine turned on with pedal not in neutral position Tripped circuit breaker Wheels spin Controller overheated Faulty drive reset circuit or switch Faulty platform circuit or switch Faulty speed control circuit or switch Check wires & connections Faulty forward/reverse circuit Check wires & connections Debris caught on squeegee Worn squeegee blades Vacuum hose clogged Vacuum hose disconnected from squeegee or recovery tank dome Recovery tank float system dirty Remove debris Rotate or replace squeegee blades Clear obstruction from hose Faulty throttle circuit or potentiometer Reverse speed only Poor or no water pickup Recovery tank not sealed Float-ball shut-off engaged, tank full Foam filling recovery tank 52 Allow pedal to return to neutral. Restart. Reset circuit breaker Decrease brush pressure Allow cool down period Check wires and connections from controller to motor Check wires and connections from and potentiometer resistance Check wires, connections and switch Check wires, connections and switch Loose motor connection Machine does not change speeds Forward speed only SOLUTION Check all battery cable connections Reset Clean connections Replace switch Unplug and stow cord Reset circuit breaker Charge batteries Reconnect vacuum hose Clean float system Latch recovery tank lid to tank. Replace damaged gaskets Empty recovery tank Empty recovery tank. Use less or different detergent. Use defoamer. 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance PROBLEM Vacuum motor does not run, or runs slowly Squeegee will not go up/down Poor scrubbing performance Little or no solution flow to the floor Brush motors do not run, or run slowly CAUSE Faulty vacuum circuit or switch Check wires connections and motor Worn vacuum motor brushes Faulty circuit or actuator Faulty cables or pulleys Debris caught in scrub brushes Worn brushes or pads Replace brushes, check commutator Check wires, connectors and actuator Repair/replace cables or pulleys Remove debris Replace brushes or pads Contact equipment or application Improper detergent, brush or pad used specialists Low battery charge Charge batteries Solution tank empty Fill solution tank Solution strainer plugged Solution system plumbing obstructed Solution solenoid valve obstructed or faulty Clean solution strainer Clear obstruction from plumbiing Low battery charge Charge battery Faulty brush circuit or motor Check wires, connections and motor Replace brushes, check commutator Worn brush motor brushes Scrub deck goes down, then raises SOLUTION Faulty actuator circuit or actuator No brushes or pad drivers on machine Chemical Reservoir empty Chemical Cap Strainer clogged Repair or replace solenoid valve Check wire connections and actuator Install brushes or pad drivers Fill reservoir Clean strainer Chemical Metering System does Chemical System plumbing obstructed Clear obstruction not operate Press prime button. If chemical flows, Faulty Flow Meter Repair/replace flow meter. Press prime button. If chemical does Faulty Chemical Pump not flow, repair/replace pump. 86395370 Operator Manual - Chariot 3 iScrub 26 53 Maintenance Controller Fault Codes ERROR CODE DELUXE PROBLEM SOLUTION TRACTION MOTOR AND CONTROLLER ERROR THE BATTERY NEEDS CHARGING OR THERE IS A BAD CONNECTION FROM THE BATTERY TO THE TRACTION CONTROLLER. CHARGE BATTERY OR CALL FOR SERVICE AND HAVE TECHNICIAN CHECK WIRING. TRACTION MOTOR DISCONNECTED THE TRACTION MOTOR HAS A BAD CONNECTION. CALL FOR SERVICE AND HAVE TECHNICIAN CHECK WIRING. TRACTION MOTOR SHORT CIRCUIT THE TRACTION MOTOR HAS A SHORT CIRCUIT TO THE BATTERY. CALL FOR SERVICE AND HAVE TECHNICIAN CHECK FOR SHORT CIRCUIT. AUX FAULT or ACTUATOR (DECK or SQUE) OVERCURRENT 54 CALL FOR SERVICE AND HAVE TECHNICIAN CHECK AUX OUTPUT DEVICES AND ASSOCIATED WIRING. VACUUM MOTOR TRIP THE VACUUM MOTOR HAS EXCESSIVE CURRENT. CALL FOR SERVICE AND HAVE TECHNICIAN CHECK FOR SHORT CIRCUIT OR OTHER DAMAGE. BRUSH MOTOR TRIP THE BRUSH MOTOR HAS EXCESSIVE CURRENT, CALL FOR SERVICE AND HAVE TECHNICIAN CHECK FOR SHORT CIRCUITS, PADS OR OTHER DAMAGE. THROTTLE TRIP ERROR THE THROTTLE IS DEFLECTED OR ASSOCIATED WIRING HAS A BREAK OR SHORT CIRCUIT. CALL FOR SERVICE AND HAVE TECHNICIAN CHECK THROTTLE AND ASSOCIATED WIRING. CONTROL SYSTEM TRIP THE TRACTION CONTROL SYSTEM IS IN ERROR. CALL FOR SERVICE AND HAVE TECHNICIAN CHECK ALL CONNECTIONS TO THE CONTROLLER. SOLENOID BRAKE THE BRAKE SOLENOID HAS A BAD CONNECTION. CALL FOR SERVICE AND HAVE TECHNICIAN CHECK CONNECTIONS TO THE BRAKE. HIGH BATTERY VOLTAGE EXCESSIVE BATTERY VOLTAGE, CALL FOR SERVICE AND HAVE TECHNICIAN CHECK BATTERY CONDITION. 86395370 Operator Manual - Chariot 3 iScrub 26 Maintenance ERROR CODE DELUXE PROBLEM MACHINE IS NOT REPORTING TO KÄRCHER FLEET SOLUTION MACHINES WITH KÄRCHER FLEET SUPPORT, CALL FOR SERVICE. MACHINES WITHOUT KÄRCHER FLEET SUPPORT, NO ACTION REQUIRED. 86395370 Operator Manual - Chariot 3 iScrub 26 55 Suggested Spare Parts - Disk 86326980 CARBON BRUSH SET VACUUM MOTOR 86368290 BRUSH SET DISK SCRUB DECK MOTORS 86161800 LATCH 86335520 WHEEL 86008710 RING 86232130 CAP 86359590 WHEEL 86362390 CASTER 86353950 HOSE, SOLUTION DRAIN 86354270 HOSE, RECOVERY 66132310 CARBON BRUSH SET DRIVE WHEEL MOTOR 86361670 BLADE, AQUAMIZER, RH 86361680 BLADE, AQUAMIZER, LH 86359570 BLADE, SQUEEGEE REAR 86359580 BLADE, SQUEEGEE, FRONT 56 86395370 Operator Manual - Chariot 3 iScrub 26 Suggested Spare Parts - Cylindrical 86326980 CARBON BRUSH SET VACUUM MOTOR 66102160 CARBON BRUSH SET CYLINDER BRUSH DECK MOTOR 86335520 WHEEL 86161800 LATCH 86008710 RING 86232130 CAP 63212390 STAR GRIP 50942310 SLEEVE 55153460 DEFLECTOR ROLL 28852940 END PIECES 66132310 CARBON BRUSH SET DRIVE WHEEL MOTOR 86354270 HOSE, RECOVERY 86353950 HOSE, SOLUTION DRAIN 69069350 ROLLER BRUSH - RED 69069810 ROLLER BRUSH - WHITE 69069820 ROLLER BRUSH - ORANGE 69069830 ROLLER BRUSH - GREEN 69069840 ROLLER BRUSH - BLACK 62732070 RUBBER LIP - OIL RESISTANT 62732900 RUBBER LIP - STANDARD 62732290 RUBBER LIP - ANTI STRIPE OIL RESISTANT 86395370 Operator Manual - Chariot 3 iScrub 26 57
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : us1mgerhart Create Date : 2016:03:29 12:59:43Z Modify Date : 2016:03:29 13:24:49-06:00 XMP Toolkit : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15 Creator Tool : FrameMaker 2015.1 Metadata Date : 2016:03:29 13:24:49-06:00 Format : application/pdf Title : 8-639-537-0-Operator-Manual-Chariot-3-iScrub-26.book Creator : us1mgerhart Producer : Acrobat Distiller 15.0 (Windows) Document ID : uuid:c045d434-887d-4353-a472-8c7ef1c3ce2a Instance ID : uuid:d7965d90-e7ee-44e6-919b-7baf12b9e5f4 Page Mode : UseOutlines Page Count : 57EXIF Metadata provided by EXIF.tools