Symbol Technologies RA1202 UHF Narrowband Radio Module User Manual
Symbol Technologies Inc UHF Narrowband Radio Module
Contents
User Manual
RA1202 User Manual Narrow Band UHF Radio Symbol Technologies Inc. RA1202 User Manual DOC. NO: PD001743A01 SHEET 1 OF 44 REVISION : B.0 Doc #: PD001743A01 Rev. B.0 Table of Contents 1.0 Revision History .................................................................................................................. 5 2.0 Introduction .......................................................................................................................... 6 3.0 General Description ............................................................................................................. 6 4.0 References ............................................................................................................................ 7 4.1 Applicable Documents and Drawings – Symbol Technologies ....................................... 7 4.2 Abbreviations and Acronyms ........................................................................................... 7 5.0 Product Level Specifications ............................................................................................... 8 5.1 Host Support..................................................................................................................... 8 5.2 UART Interface ................................................................................................................ 8 5.3 Radio Protocols and Features ........................................................................................... 8 5.4 Support and Test Software ............................................................................................... 9 5.5 Network Access................................................................................................................ 9 5.6 RF protocol ....................................................................................................................... 9 5.7 RF Connectivity ............................................................................................................. 10 5.8 Unsupported Features ..................................................................................................... 10 6.0 Applicable Approvals ........................................................................................................ 10 7.0 Approvals and Safety Summary ........................................................................................ 11 7.1 FCC Information to Users .............................................................................................. 12 7.2 Warning to Users ............................................................................................................ 12 7.3 FCC & IC RF Exposure Warning .................................................................................. 12 7.4 Labeling Requirement for Radio Module ...................................................................... 12 7.5 Labeling Requirement for Host ...................................................................................... 13 7.6 Testing requirements for portable Host .......................................................................... 13 7.7 Testing requirements for Mobile Host ........................................................................... 13 Symbol Solutions, Inc. Symbol Confidential Restricted Page 2 of 22 Doc #: PD001743A01 Rev. B.0 Colocated Transmitters .................................................................................................. 13 7.8 8.0 General ............................................................................................................................... 14 8.1 Description ..................................................................................................................... 14 8.2 Block Diagram – Radio Module .................................................................................... 14 9.0 Interfaces ............................................................................................................................ 14 9.1 Interface and Connection Scheme .................................................................................. 15 9.2 Antenna Connection ....................................................................................................... 17 10.0 Electrical Characteristics ................................................................................................... 18 10.1 Power Supply Requirements ...................................................................................... 18 10.2 Modes of Operation .................................................................................................... 18 11.0 Software Features and Functions ....................................................................................... 18 11.1 Radio Module Firmware ............................................................................................. 18 11.2 Radio module serial number storage .......................................................................... 18 11.3 Radio Type storage and security ................................................................................ 18 11.4 Radio Protocol ............................................................................................................ 19 11.5 Radio Calibration data ................................................................................................ 19 12.0 Host Software..................................................................................................................... 19 12.1 Radio Tests ................................................................................................................. 19 12.2 Configuration and Tuning .......................................................................................... 19 12.3 Site Survey (terminals only) ....................................................................................... 20 12.4 Software Update feature ............................................................................................. 20 13.0 Mechanical & Ergonomic Specifications .......................................................................... 20 13.1 General........................................................................................................................ 20 13.2 Drop Rating ................................................................................................................ 20 13.3 Environmental Conditions .......................................................................................... 21 Symbol Solutions, Inc. Symbol Confidential Restricted Page 3 of 22 Doc #: PD001743A01 Rev. B.0 Labeling Requirements ............................................................................................... 21 13.4 14.0 Appendices ......................................................................................................................... 22 14.1 General........................................................................................................................ 22 14.2 Receiver ...................................................................................................................... 22 14.3 Transmitter.................................................................................................................. 22 14.4 Host Interface ............................................................................................................. 22 Symbol Solutions, Inc. Symbol Confidential Restricted Page 4 of 22 Doc #: PD001743A01 Rev. B.0 1.0 Revision History REV DESCRIPTION DATE Author A.0 Initial Release Sep. 12, 2014 Armia Nazeer B.0 - Added regulatory comments as per Ultratech’s request. Sep. 18, 2014 Sada, Irfan, Armia - Removed confidential information. Ex. Block diagram Symbol Solutions, Inc. Symbol Confidential Restricted Page 5 of 22 Doc #: PD001743A01 2.0 Rev. B.0 Introduction This document is the user manual for the RA1202 Narrow Band Radio module. It describes its function and specifications as well as general architectural details. All references to Symbol in this document refer to Symbol Technologies Inc. 3.0 General Description RA1202 is a Narrow Band UHF radio module for data only (no audio) communications. The radio is primarily to be integrated into Symbol’s handheld XT15 and vehicle mount VH10 as well as other potential future undetermined hosts. There are 2 hardware variants of the radio module: 403-435 MHz and 435-470 MHz. The 2 hardware variants are configured during manufacturing into 12 radio types to meet different countries’ approved frequency band, channel spacing, power level, baud rate and sub-band restrictions. RA1202 supports the following Symbol’s modulations: 2 level 4800, 2 level 9600, 4 level 9600, 4 level 19200 baud FSK modulations at 12.5, 20, 25 KHz channel spacing with factory configured output power of either 1W (+30dBm) or 0.45W (+26.5dBm)(non-FCC). Communication between the radio and host is through a serial interface. Radio firmware resides on a microcontroller inside the radio modules onboard flash memory. The antenna port of the radio module is of u.Fl type and is meant for connection to an external antenna that is part of the host device RA1202 is designed to be integrated into a client host device only. It is not suitable for use as a base station radio. RA1202 is backward compatible with the following legacy Symbol radios: RA1001A; RA1001; TRX7370; TRX7345 (4 level modulations only); Symbol Solutions, Inc. Symbol Confidential Restricted Page 6 of 22 Doc #: PD001743A01 4.0 4.1 Rev. B.0 References Applicable Documents and Drawings – Symbol Technologies Doc./Dwg No. PD001744A01 PD001746A01 PD001745A01 PD001747A01 PD001748A01 Description Radio module manufacturing test procedure Radio module manufacturing control plan Radio module manufacturing tester specification RA1202 product requirements document (export from Cradle tool) Includes: System requirements Hardware requirements Software requirements Hardware Block Diagram PD001749A01 Software architecture 4.2 Abbreviations and Acronyms API BIST BER EMC EMI ESD FCS MCU MER MTBF MTTR POST SAR SINAD WLAN UI FSK Symbol Solutions, Inc. Symbol Confidential Restricted Application Programmer’s Interface Built-in Self Test Bit Error Rate Electro Magnetic Compatibility Electro Magnetic Interference Electro Static Discharge First Customer Ship Micro-Controller Unit Message Error Rate Mean Time Between Failure Mean Time To Repair Power ON Self Test Specific Absorption Ratio Signal to Noise and Distortion ration Wireless Local Area Network User Interface Frequency Shift Keying Page 7 of 22 Doc #: PD001743A01 5.0 Rev. B.0 Product Level Specifications The RA1202 provides narrowband data communications using legacy Symbol proprietary narrowband protocol and FM modulation schemes. These include: 2 level FSK running at 4800 and 9600 bps 4 level FSK running at 9600 and 19,200 bps The RA1202 is functionally backward compatible for all modulations with currently existing Symbol narrowband radios including RA1001A; RA1001; TRX7370, TRX7355 (4 level modulations only). The implementation of the RA1202 is modular and is meant for integration in Symbol’s XT15 handheld and VH10 vehicle mount terminals as well a future potential host device. For a usable radio system an external antenna system, antenna feed cable and data and power interface board will be necessary for integration with any target host as required, the design of which shall not be covered under this specification. An interface board is necessary to provide conversion of host power from host voltage to required radio voltage as well as for providing appropriate mechanical connection between the host device and the radio, and for data interconnect. 5.1 Host Support RA1202 is initially intended to be integrated into the following hosts: XT15 handheld terminal with WinCE 6.0 operating system VH10 vehicle mount terminal with WinCE 6.0 operating system The open architecture of RA1202 is designed to allow ease of integration with any potential future host devices by limiting the connection to single power supply and communications bus (RS232 UART serial interface). In addition to electro-mechanical integration a driver will be required for using the radio module in alternate operating systems such as but not limited to Windows CE 7 and Windows 7. 5.2 UART Interface A UART interface is required for communication between the host and the radio. 5.3 Radio Protocols and Features The following protocols are supported by the RA1202: Symbol Solutions, Inc. Symbol Confidential Restricted Page 8 of 22 Doc #: PD001743A01 5.4 Rev. B.0 Polling protocol and cellular protocol is supported. New polling protocol and non-Cellular is not supported. TESS and ANSI DATA stream as payload is supported via Open TekTerm application for terminals. Support and Test Software The following software is available for use with the RA102 radio module: RTest command line utility which can used by manufacturing to configure the radio parameters or alternatively to operate radio test only modes. Functions include: Program frequency Select channel spacing Select data Rate Select TX power (Between 1W and 0.45Watt) Select continuous receive mode Select continuous transmit mode (60 seconds time out timer) BER test for real time BER (Bit Error Rate) testing. Radio firmware update utility NBDebug an application suitable for use for software integration and for product support to test polling protocol and cellular client. The debug is time stamped and has multiple debug levels to allow for efficient debug of any issues during software integration. SAR application – Intended for testing SAR for host device. Allows for continuous NB transmit mode at a certain duty cycle simultaneously with any if present host WiFi and Bluetooth radios. Site survey software tools for configuration into customer site 5.5 Network Access The RA1202 is compatible when appropriately configured for network access to the following base stations: 5.6 Symbol’s 9150, 9160, 9160 G2 Access Point & Base Station for all modulations. 9140 base station when combined with Symbol’s 93xx/94xx/95xx Series of Network Controllers for 4 level modulations only. RF protocol The RA1202 supports Symbol’s NB Polling Protocol (Cellular mode only) and is compatible with all current 32-bit 4800/9600/19,200 symbol systems. Roaming is transparent via 9140 (4 level modulations only), 9150, 9160 and 9160 G2 Access Point cell base mode Symbol Solutions, Inc. Symbol Confidential Restricted Page 9 of 22 Doc #: PD001743A01 5.7 RF Connectivity 5.8 Rev. B.0 Frequency range: - 403 - 435 MHz, 435 – 470 MHz Data rate & modeError! Bookmark not defined.: 2 level FSK 4800 bps, 1 2 level FSK 9600 bps 4 level FSK 9600 bps 4 level FSK 19.2 Kbps RF Power: Factory set to 0.45 watt (non-US) or 1 watt Channel Spacing: 12.5 KHz 20 KHz (non-US & Canada) 25 KHz (not for Part 90) Sensitivity2: 0.5uV nominal @ 1% BER [12.5 kHz] or better 0.7uV nominal @ 1% BER [20/25 kHz] or better Unsupported Features The following features are not supported by the RA1202 radio module: 6.0 TelkTalk is not supported. Intrinsically Safe is not supported Formal MTBF – Formal calculations to MIL-HDBK-217F will not be provided Non-cellular protocol is not supported Not backward compatible to 9130 and 9140 base stations for 2 level modulations only. Applicable Approvals The RA1202 is pending submission for approval for the following certifications: i. ii. FCC Compliance and Approval a. Modular compliance and approval as per CFR47 Part 90, 22, 74, 80 and Part 15. Industry Canada Compliance and Approval Effective peak data rate Above are radio module only receiver sensitivity outside of a host. Host receiver sensitivity depends on host EMC characteristics. Symbol Solutions, Inc. Symbol Confidential Restricted Page 10 of 22 Doc #: PD001743A01 iii. iv. v. Rev. B.0 a. Modular compliance and approval as per RSS-119 section (IEC-003) unintentional emissions. ETSI EN 300-113 Compliance ETSI EN 300-220 Compliance FCC, IC, ETSI – coexistence of Radio Approvals a. When RA1202 radio module is integrated into XT15 and VH10 host devices, coexistence of NB Radio with WLAN and BT as applicable by: i. FCC CFR47 Part 90 (Tx harmonics) and Part 15 subpart B class B ii. Industry Canada RSS-190 (IEC003) Tx harmonics iii. All SAR (FCC bulletin 65, EN 50392, Australian SAR ‘Radiocomms (EMR - Human Exposure) Standard 2003 - amended 2007 & EMR SAR ARPANSA Radiation Protection’) iv. EMC EN 301 489-1-17-5 v. EMI EN 55022 class B vi. EU WiFi radio 2.4GHz type EN 300 328 Tx harmonics vii. EU WiFi radio 5GHz type EN 301 893 Tx harmonics vi. vii. viii. ix. x. xi. 7.0 Australian/New Zealand standard AS/NZS 4768.1:2010. Malaysian Communications and Multimedia Commission standard to be used in Land Mobile Services as per SKMM WTS LMR 1.01:2007. RA1202 when integrated into XT15 and VH10 hosts a. ETSI EN 301 489-1-17-5. CE Mark Compliance. Safety a. EC Low Voltage Directive 73/23/EEC, but no voltage limit applying. Flammability Rating a. The PCB used for the RA1202 radio module is UL94-V0 (or better) rated. Symbol Solutions Inc W18 environmental compliance, which is a superset of RoHs, REACH, China RoHs, Conflict materials and PVC content. Approvals and Safety Summary This equipment complies with Class B Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Symbol Solutions, Inc. Symbol Confidential Restricted Page 11 of 22 Doc #: PD001743A01 7.1 Rev. B.0 FCC Information to Users For Class B Unintentional Radiators: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures: 7.2 Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Warning to Users Changes or modifications not expressly approved by Symbol Technologies Inc, the party responsible for compliance, may void the user's authority to operate the equipment. 7.3 FCC & IC RF Exposure Warning A separation Distance of at least 22 cm is required to be maintained between the user and the antenna when the antenna with the gain of less than or equal to 2 dBi is used for Mobile Application. A separation distance of at least 70 cm is required to be maintained between the user and the antenna when the antenna with the gain of less than or equal to 12 dBi is used for Fixed base application. VH10 collocation evaluation is based on 0 dBi gain antenna requiring a separation distance of at least 20 cm. 7.4 Labeling Requirement for Radio Module A label is affixed to the radio module with the following information: Symbol Technologies Inc UHF Radio, Model RA1202 FCC ID: H9PRA1202 Symbol Solutions, Inc. Symbol Confidential Restricted Page 12 of 22 Doc #: PD001743A01 Rev. B.0 IC: 1549L-RA1202” 7.5 Labeling Requirement for Host After installing the radio module in a host if the label is not visible from outside then a separate label has to be affixed to the outside of the host with following information: “Contains Symbol Technologies Inc UHF Radio, Model RA1202 FCC ID: H9PRA1202 IC: 1549L-RA1202” 7.6 Testing requirements for portable Host Testing of portable 7545MBWN has been addressed pending application, for any other portable hosts with radio module RA1202 integrated requires Class II permissive change approval. 7.7 Testing requirements for Mobile Host RA1202 integrated in a mobile host requires testing for DoC or Certification as a Class B device. 7.8 Collocated Transmitters Collocation with other transmitters for portable 7545MBWN has been addressed pending application, for any other portable host new certification is required. Symbol Solutions, Inc. Symbol Confidential Restricted Page 13 of 22 Doc #: PD001743A01 Rev. B.0 Section B – Detailed Specifications 8.0 General 8.1 Description The radio module consists of 54-pin interface, microcontroller, modem chipset, transmitter, receiver, RF front end for transmit and receive, Tx/Rx switch and antenna port as shown below. Host sends commands and bidirectional data to the microcontroller (MCU) through the UART interface on the 54-pin interface. MCU sends data and control signals to the modem chipset, which modulates the data in one of 4 of Symbol’s 4 modulation types: 2L 4800, 2L 9600, 4L 9600, 4L 19200 baud rate. Modem outputs IQ data to transmitter, which modulates data to RF carrier, amplifies it and outputs it on antenna port when Tx/Rx switch is set to transmit position. When Tx/Rx switch is set into Rx positions, received data is filtered, amplified, de-modulated by receiver and then decoded by modem. Modem sends data to MCU, where it is buffered and relayed back to the host device. Radio module also includes mechanical structures for support and shielding: top shield, radio frame and bottom shield. 8.2 Block Diagram – Radio Module Refer to confidential block diagram. 9.0 Interfaces The figure below describes the connection and interface scheme for RA1202 Symbol Solutions, Inc. Symbol Confidential Restricted Page 14 of 22 Doc #: PD001743A01 Rev. B.0 Radio Module 54pin I/F Antenna U.FL Connector 9.1 Interface and Connection Scheme The RA1202 module power and data bus connector is as follows: Radio module connector: Samtec ASP-176298-02 (8.7mm custom pin lengths of Samtec FTE-125-xx-G-DV-A-P-TR series) Mating host connector: Samtec CLE-127-01-G-DV-A-K Pin 1 of the radio board (part of the RA1202 radio module) has a square solder pad and silkscreen. Below pin-out is from the radio module’s reference point. Pin Number Signal Name Description 11 13 15 17 19 21 RX_I_CAL_P RX_I_CAL_N GND TX_Q_CAL_P TX_Q_CAL_N GND TX_I_CAL_P TX_I_CAL_N GND ABOUT_TO_TX BACKUP_ACTIVE Receiver differential I signal from receiver to modem Ground Transmitter differential Q signal from modem to transmitter. Ground Transmitter differential I signal from modem to transmitter. Ground Indicator when about to transmit Set when radio should go into emergency suspend mode (ex. Battery removal on handheld host). Symbol Solutions, Inc. Symbol Confidential Restricted Page 15 of 22 Voltage (V) 1V p-p 3.0 3.3 Direction (wrt Radio Module) I - Input O - Output A – Analog Pull Up or Pull Down Test Signal – not connected Test Signal – 100Kohms Test Signal – 100Kohms None PD (1M on Radio Bd) Requires 10kohm series resistor on host. Doc #: PD001743A01 23 WAN_PWR_EN 25 MCU_PWR_EN 27 29 31 33 35 37 39 41 43 45 47 49 51 53 GND MCU_UART2_RX MCU_UART2_CTS MCU_UART2_TX MCU_UART2_RTS JTAG_TRST_N/SPARE-2 GND GND GND GND VSYS VSYS VSYS VSYS Symbol Solutions, Inc. Symbol Confidential Restricted Rev. B.0 Power enable for the radio module from the hsot Indicator when MCU power is enabled Ground MCU serial port 2 (RS232 channel to the host) Ground Ground Ground Ground Radio Module Power Supply Page 16 of 22 3.3 PD (100K on Radio Bd) PD (10K on Radio Board) 3.0 3.0 3.0 3.0 3.0 None None None None None 3.2 to 4.2 Power Tx current: 1.5A @ 3.7V nominal Doc #: PD001743A01 Rev. B.0 Pin Number Signal Name Description RX_Q_CAL_N RX_Q_CAL_P GND UPS_MODE Receiver differential Q signal from receiver to modem Ground Indicator from Host to MCU radio to go into lower power mode. 10 12 14 16 NOT USED NOT USED GND TX_ON (RF_PA_GATE_EN) 18 20 GND SYMBOL_CLK 22 24 26 28 30 32 34 GND MCU_UART3_TX MCU_UART3_RX GND ** MCU_BOOT1 ** MCU_BOOT0 MCU_RST_N 36 38 40 42 44 46 48 50 52 GND DO NOT USE JTAG_TCK JTAG_TDI/SPI3_NCC JTAG_TDO/MCU_HRTBEAT DO NOT USED GND JTAG_TMS/SPARE-1 MCU_SPARE_3 Ground TX trigger signal from modem for test equipment. Ground Symbol clock from modem chipset Ground MCU serial port 3 (MCU program and debug) Ground MCU boot configuration Voltage (V) 3.0 Direction (wrt Radio Module) I - Input O - Output A – Analog Pull Up or Pull Down Test Signal – not connected PD (100k on Radio Board) Future feature to be implemented Test Signal – not connected 3.0 3.0 3.0 3.0 PD (100K on Radio Board) PD (100K on Radio Board) JTAG clock to the MCU. JTAG shared as SPI CS JTAG shared as debug signal 3.0 3.0 3.0 PD (INT) None None Ground JTAG shared as Spare GPIO Spare GPIO 3.0 3.0 Undefined Undefined None None MCU reset control signal ** MCU_BOOT[1:0] = x0 MCU boot from MCU flash memory MCU_BOOT[1:0] = 01 MCU boot from system memory MCU_BOOT[1:0] = 11 MCU boot from Embedded SRAM 9.2 Antenna Connection Connector: Hirose U.FL-R-SMT(10) Antenna: 50 Ohm nominal impedance; external only, via interconnecting RF cable. Recommend having a ferrite choke on RF antenna cable. Symbol Solutions, Inc. Symbol Confidential Restricted Page 17 of 22 Doc #: PD001743A01 Rev. B.0 10.0 Electrical Characteristics 10.1 Power Supply Requirements Input Voltage Range Nominal Input Voltage Current consumption at nominal input voltage OFF Idle Receive Transmit 3.2 to 4.2 Vdc 3.7Vdc TBD mA TBD mA <200mA 1.5A nominal at 1Watt output 10.2 Modes of Operation RA1202 radio module shall support the following modes of operation: OFF (Radio powered down, Power can remain present on Radio module interface) Idle (Radio module MCU powered, but modem, transmitter, receiver and RF front end off) Receive Transmit 11.0 Software Features and Functions 11.1 Radio Module Firmware Radio module firmware running on the Radio module microcontroller (MCU) communicates with the host, controls all aspects of the radio chipsets, RF front end and Tx/Rx switch. 11.2 Radio module serial number storage During manufacturing, radio module serial number and part number are stored into the radio module MCU write-once non-volatile flash memory. This allows host to query radio module part number and serial number and therefore allow correlation of each radio module with the factory test report. 11.3 Radio Type storage and security RA1202 radio module has 2 hardware types. These 2 hardware types are configured during manufacturing into 12 different radio types to meet country region approval requirements. Radio type is factory set and stored in the radio MCU non-volatile memory. Radio type is locked outside of manufacturing of the radio module. There are 3 levels of security to ensure end users cannot modify the radio type outside of factory or authorized service depots: Symbol Solutions, Inc. Symbol Confidential Restricted Page 18 of 22 Doc #: PD001743A01 Rev. B.0 Locked and signed software does not allow access to commands to modify radio type. Control panel in windows can only read the radio type. Password protection. This is added security beyond the locked and signed software. Specialized commands to change radio types, which are only available in manufacturing and authorized service depots. 11.4 Radio Protocol Drivers are available supporting the following features: Compatible with Symbol’s NarrowBand Polling Protocol Cellular only. Non-cellular modes not be supported. Transparent roaming and power saving modes (terminals only). 9130/9140 2L modulation base stations not be supported RMAN API interface supported by the TekTerm application (terminals only) Radio protocol diagnostic information (viewable via TekTerm for terminals) 11.5 Radio Calibration data All calibration parameters are calibrated and tested during manufacturing then locked out from end customers. 12.0 Host Software 12.1 Radio Tests RTest command line utility allow developers and approval testers to perform the following radio tests: Channel (frequency) selection Transmit long Transmit test Receive Test (BER) 12.2 Configuration and Tuning RTest allows developer, manufacturing and approval tester to configure all necessary radio settings such as data rate, modulation type and operating frequency. End user shall not be able to modify any approval related parameters of the radio module. This is done by 3 layers of protection described in section 11.3 of this document. Symbol Solutions, Inc. Symbol Confidential Restricted Page 19 of 22 Doc #: PD001743A01 Rev. B.0 12.3 Site Survey (terminals only) A site survey application shall be developed for RA1202 that will perform in a similar manner to the site survey application available on 7530 G2 and 8525/8530 G2 terminals. This is used by system installers to determine the best location of base stations for new NarrowBand sites. It also indicates the coverage level. 12.4 Software Update feature Software is available to upgrade RA1202 firmware through UART host connection, for insystem upgrade and depot upgrade. As a backup in case of flash corruption and serial interface no longer operational it is possible to update firmware through JTAG programming interface. Only firmware which Regulatory Agency approved can be loaded on the radio module. 13.0 Mechanical & Ergonomic Specifications 13.1 General Interface to Host: 54-pin Samtec ASP-176298-02 (8.7mm custom pin lengths of Samtec FTE-125-xx-G-DV-A-P-TR series) Antenna Cable Interface: Weight: Dimensions: Hirose U.FL-R-SMT(10) 37.1g 64 (W) x 52.5 (L) x 17.1 (H) mm 13.2 Drop Rating This is highly dependent upon host mounting system. For RA1202 Radio module integrated into MSI XT15 handheld terminal the following drop specifications are met: 26 drops from 1.7m at room temperature to polished concrete 6 drops from 2.0 m at room temperature to polished concrete 6 drops from 1.7 m at -20C to polished concrete 6 drops from 1.7m at +50C to polished concrete Symbol Solutions, Inc. Symbol Confidential Restricted Page 20 of 22 Doc #: PD001743A01 Rev. B.0 13.3 Environmental Conditions Storage temperature: Operating temperature: Humidity*: -35C to +85C -30C to +80C 5% to 95% (non-condensing) Temperature shock*: -30C to +50C (85% R.H.) as per MIL-STD810G; Method 503.5 Procedure I-C (Multicycle shocks) * There will be NO environmental protection on the RA1202 radio module, as it is designed to be fully enclosed within a host unit. 13.4 Labeling Requirements 3 different labels must be in the following 3 locations: External to RA1202 radio module External to host unit External to host unit shipping box They must include all applicable notices as per regulatory requirements of section 5.0 adhering to the minimum text and label sizes defined therein. Identify Symbol Technologies Inc RA1202 radio module and part number specific to the radio configuration. Symbol Solutions, Inc. Symbol Confidential Restricted Page 21 of 22 Doc #: PD001743A01 Rev. B.0 14.0 Appendices Radio Performance Specifications 14.1 General Frequency Range: Frequency Control: Channel Spacing: Mode of Operation: Regulated Supply Voltage: Operating Temperature Range: Maximum Dimensions: Weight: FCC Compliance: 435-470 MHz [high band – FCC, IC, EU, & other] 403-435 MHz [low band – non-FCC, non-IC] Synthesized 12.5 kHz [FCC & others] 20 kHz [non-FCC] 25 kHz non Part 90 Simplex or Half Duplex 3.7VDC +/- 15% -30C to +80C 64 (W) x 52.5 (L) x 17.1 (H) mm 37.1g Yes [high band only – 435-470 MHz] No [low band] 14.2 Receiver Bandwidth: Frequency Stability: Digital Sensitivity 35 MHz [high band] 32 MHz [low band] +/- 1ppm [-30C to + 80C] 0.4uV at 1% BER [at 12.5 kHz channel spacing] as per ETSI EN300 113-1 v 1.7.1 RF Input Impedance Selectivity Spurious Rejection Intermodulation Conducted Spurious Receive Current Drain Receive Attach Time 50 ohms -61 dB [12.5 kHz channel spacing] 88 dB -70dB 85 dB 200 mA < 3.5 msec 14.3 Transmitter Bandwidth: Frequency Stability: TCXO coupling RF Output Power RF Output Impedance Modulation Distortion Maximum Duty Cycle Transmitter Attack Time Spurious & Harmonic FM Transmit Current Drain 35 MHz [high band] 32 MHz [low band] +/- 1ppm [-30C to + 80C] AC 1W nominal 0.5W [available for non-FCC variant] 50 ohms < 3% 30%, 60 seconds maximum continuous transmit time < 3.5 msec -79 dB 1.5A at 3.7 VDC nominal 14.4 Host Interface Data Input Impedance Symbol Solutions, Inc. Symbol Confidential Restricted 100 Kohms Page 22 of 22
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : ikadri Create Date : 2014:09:19 11:41:35-04:00 Modify Date : 2014:09:19 12:07:14-04:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2014:09:19 12:07:14-04:00 Creator Tool : Acrobat PDFMaker 10.1 for Word Document ID : uuid:11794486-3256-49ee-ad06-2d29726a5a96 Instance ID : uuid:6af2221b-cc3e-4586-af94-edc6c0ddef17 Subject : 2 Format : application/pdf Creator : ikadri Producer : Adobe PDF Library 10.0 Source Modified : D:20140919154109 Company : Motorola Page Layout : OneColumn Page Count : 22EXIF Metadata provided by EXIF.tools