Users Manual
SYMEO LPR® Product Documentation Product: LPR® -1D SYMEO Local Positioning Radar System ® LPR -1D Product Documentation CONTENT OVERVIEW ...................................................................................................... 7 1.1 Safety Instructions ................................................................................................... 8 1.2 Installation ................................................................................................................ 8 1.3 Repairs ...................................................................................................................... 9 1.4 Transport and Storage ............................................................................................. 9 1.5 Power Supply ............................................................................................................ 9 1.6 Setup and Operation ................................................................................................ 9 1.7 System Extensions and Accessories .................................................................... 10 1.8 Additional Instructions regarding Compact Type and Integral Type Units ........ 10 SYSTEM DESCRIPTION ............................................................................... 11 2.1 System architecture ............................................................................................... 11 2.2 Technical Data ........................................................................................................ 11 2.3 System Configuration ............................................................................................ 12 2.4 2.4.1 2.4.2 2.4.3 System Design ........................................................................................................ 13 Station-ID (SID) ........................................................................................................ 13 Group-ID (GID) ......................................................................................................... 14 FSK Channel (FSK) .................................................................................................. 14 2.5 Mode of Operation of the System .......................................................................... 15 2.6 2.6.1 2.6.2 2.6.3 Application Examples ............................................................................................ 15 Redundant arrangement (2 x LPR-1DX) ................................................................... 15 Positioning of Crane Crab (LPR® 1DP2) ................................................................... 17 Positioning of 2 Cranes on two Runways (LPR® 1DP) .............................................. 18 HARDWARE .................................................................................................. 19 3.1.1 Casing ...................................................................................................................... 19 3.1.2 General internal connections .................................................................................... 21 3.2 3.2.1 3.2.2 3.2.3 LPR® - 1D unit with TCP/IP interface ..................................................................... 23 Front elements.......................................................................................................... 23 Overview internal connectors .................................................................................... 23 Mode of operation ..................................................................................................... 24 3.3 LPR® - 1D unit with Profibus interface .................................................................. 24 3.3.1 Front elements.......................................................................................................... 24 Overview Copyright © Symeo GmbH 2012 Page 2 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 3.3.2 3.3.3 3.3.4 3.3.5 3.3.6 3.3.7 3.3.8 Overview internal connectors .................................................................................... 26 Connection to Profibus ............................................................................................. 26 Connection of service port with serial interface ......................................................... 27 Termination of Profibus ............................................................................................. 28 Addressing the Profibus ............................................................................................ 29 Measurement frequency ........................................................................................... 30 Mode of operation ..................................................................................................... 30 3.4 3.4.1 3.4.2 3.4.3 3.4.4 LPR® - 1D unit with RS232 interface ...................................................................... 30 Front elements.......................................................................................................... 30 Overview internal connectors .................................................................................... 31 Connection of service and data port with serial interface .......................................... 32 Mode of operation ..................................................................................................... 33 3.5 LPR® Antenna Types .............................................................................................. 34 3.5.1 Adapter for different LPR® Antennas......................................................................... 36 INSTALLATION ............................................................................................. 37 4.1 Installation of LPR® Unit Design Compact Unit .................................................... 37 4.1.1 Important Instructions for Installation ........................................................................ 37 4.1.2 Installation ................................................................................................................ 38 4.2 4.2.1 4.2.2 4.2.3 4.2.4 Installation of LPR® Antennas ............................................................................... 38 Connecting and Wiring up the Antenna and Cable ................................................... 38 Installing the Antenna(s) ........................................................................................... 39 Fresnel zone ............................................................................................................. 40 Installation of Planar Antennas ................................................................................. 40 COMMISSIONING .......................................................................................... 41 5.1 Requirements.......................................................................................................... 41 5.1.1 General..................................................................................................................... 41 5.2 Connection to LPR® Unit with TCP/IP Interface .................................................... 42 5.3 Connection to LPR® Unit with serial RS232 interface or Profibus interface ....... 44 5.4 Commissioning Tool – LPR® 1D Wizard................................................................ 45 5.4.1 Installation ................................................................................................................ 45 5.4.2 Utilization of LPR® 1D Wizard ................................................................................... 45 WEB SERVER................................................................................................ 58 6.1 Open Web Server .................................................................................................... 58 6.2 6.2.1 6.2.2 6.2.3 6.2.4 Settings ................................................................................................................... 59 „LAN“ area ................................................................................................................ 60 „Network“ Area ......................................................................................................... 60 „Serial-to-Ethernet“ Area ........................................................................................... 61 „Remote Access“ Area.............................................................................................. 63 Overview Copyright © Symeo GmbH 2012 Page 3 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 6.2.5 „Miscellaneous“ Area ................................................................................................ 64 6.2.6 „Special Functions“ Area .......................................................................................... 64 6.2.7 Accept settings / System Reboot .............................................................................. 64 6.3 System Status ......................................................................................................... 66 6.4 Diagnostics ............................................................................................................. 67 6.5 6.5.1 6.5.2 6.5.3 6.5.4 Update Firmware .................................................................................................... 68 Step 1 – File system ................................................................................................. 69 Step 2 – Linux Kernel ............................................................................................... 71 Step 3 – Optional: Userspace ................................................................................... 73 Step 4 – Restart ........................................................................................................ 73 6.6 System Log ............................................................................................................. 74 PROTOCOL DESCRIPTION BINARY XP (1D MESSAGES) ........................ 76 7.1 7.1.1 7.1.2 7.1.3 7.1.4 General Description................................................................................................ 76 Direction of Data ....................................................................................................... 76 Structure of Data Packet ........................................................................................... 76 Byte Stuffing ............................................................................................................. 77 CRC ......................................................................................................................... 77 7.2 7.2.1 7.2.2 7.2.3 7.2.4 Data Types .............................................................................................................. 78 Type 0x00 – Distance Data....................................................................................... 78 Type 0x01 – User Data ............................................................................................. 79 Type 0x02 – Send Request ...................................................................................... 80 Type 0x03 – Relays Switching Command................................................................. 80 7.3 TCP/IP option: Fixed Frame Protocol .................................................................... 81 7.3.1 Detailed description TCP Fixed-Frame Protocol ....................................................... 81 7.3.2 Detailed description UDP Fixed-Frame Protocol ....................................................... 81 7.4 Remarks .................................................................................................................. 82 7.4.1 LPR® 1D Address ..................................................................................................... 82 7.4.2 Distance Error codes ................................................................................................ 82 PROTOCOL DESCRIPTION FOR PROFIBUS INTERFACE......................... 83 8.1 Profibus data structure .......................................................................................... 83 8.2 Error messages ...................................................................................................... 84 TROUBLE SHOOTING .................................................................................. 85 9.1 9.1.1 9.1.2 9.1.3 9.1.4 Programs................................................................................................................. 85 Terminal Program ..................................................................................................... 85 Command Window (only for LPR unit with TCP/IP interface) .................................... 85 Telnet (only for LPR unit with TCP/IP interface) ........................................................ 85 Browser (only for LPR unit with TCP/IP interface) ..................................................... 85 Overview Copyright © Symeo GmbH 2012 Page 4 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 9.1.5 Network Scanner (only for LPR unit with TCP/IP interface)....................................... 85 9.2 Hardware ................................................................................................................. 85 9.3 Connection to LPR units with RS232 or Profibus interface ................................. 85 9.3.1 RealTerm (for service port) ....................................................................................... 87 9.4 9.4.1 9.4.2 9.4.3 9.4.4 Connection to the LPR unit with TCP/IP interface ................................................ 87 LAN Settings of your PC ........................................................................................... 88 Check TCP/IP connection ......................................................................................... 88 RealTerm (for service port) ....................................................................................... 89 Web Interface ........................................................................................................... 90 9.5 No Measurements ................................................................................................... 92 10 APPENDIX A: AGENCY CERTIFICATIONS ................................................. 94 United States (FCC) and Canada (Industry Canada) ....................................................... 94 United States (FCC) ........................................................................................................... 94 Canada (Industry Canada) ................................................................................................. 96 11 APPENDIX B: TABLE OF COUNTRIES AND REGULATIONS .................... 97 Overview Copyright © Symeo GmbH 2012 Page 5 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation The documentation for the LPR® 1D product is published by: SYMEO GmbH Prof.-Messerschmitt-Str. 3 D-85579 Neubiberg www.symeo.com If you have any questions or suggestions, please contact: Email: info@symeo.com phone: +49 89 660 7796 0 Copyright Symeo GmbH 2007 All rights reserved HISTORY Overview 3.17 14.12.2008 New Layout 3.18 11.02.2009 Added all single documents to one master document 3.19 30.03.2009 Added notes for FCC/IC conformity 3.20 13.07.2010 Corrections FCC notes 3.21 14.03.2012 Merge of all versions, new release Wizard 4.x SYMBOLS USED The following symbols are used throughout the documentation: This symbol appears before instructions that must be followed at all times. Failure to comply with these instructions will result in personal injury. This symbol appears before instructions that must be followed at all times. Failure to comply with these instructions will result in damage to equipment. This symbol appears before information of particular importance. All rights reserved, particularly those relating to the translation, reprinting, and reproduction by photocopying or similar processes of all or part of the documentation. All rights reserved, particularly for purposes of the award of patents or submission of utility models. Patent pending 10/496,886 Patent pending 11/578,094 Delivery options and technical changes reserved. Published by SYMEO GmbH Overview Copyright © Symeo GmbH 2012 Page 6 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Overview SYMEO Industrial LPR® is a system for contactless, real-time determination of distances and positions. LPR® 1D is a distance measurement system which is particularly well suited for use in very harsh, industrial environments, in which other systems such as mechanical rotary encoders or lasers cannot function for long periods. The Local Positioning Radar System LPR® 1D consists of equal components, which are configured as (depending on customer‟s application): LPR® Slave Unit or LPR® Group Master Unit Figure 1 – LPR® hardware: Group Master Unit or Slave Unit in the design “Compact Unit” The difference between a LPR® 1D Group Master Unit and a LPR® 1D Slave Unit is only the configuration but not the hardware. A LPR® 1D system consist exactly of one component Group Master Unit. And it consists furthermore of one to four LPR® 1D components Slave Unit, subsequent named slave unit 1, 2, 3, 4. Depending on customer‟s application the LPR® 1D hardware has different interfaces. The unit in the design Compact Unit has IP65 protection. Overview interfaces Antenna ports Power Supply RS232 TCP/IP Profibus Relay 2 or 4 10-36 Volt DC Configuration and Data Interface Optional: Configuration and Data Interface Data Interface Optional: 7 Dry Contacts Overview Copyright © Symeo GmbH 2012 Page 7 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation In special application cases it is also possible to get a LPR® unit with an integrated antenna. This hardware is called LPR® design ”Integral Unit” compared to the hardware LPR® 1D design “Compact Unit”. Figure 2 – LPR® Hardware – Special Case: Group Master Unit or Slave Unit with integrated antenna in the design “Integral Unit” The LPR® 1D unit with an integrated antenna is available in a plastic housing. An installation description is delivered separately to this document. This antenna is not approved to be in compliance with part 15 of FCC rules and with RSS-210 of Industry Canada. Usage of these antennas may void the FCC/ IC authorization to operate this equipment. Further information is found in the Appendix. 1.1 Safety Instructions LPR®-1D systems are purely tracking and assistance systems. They therefore do not satisfy special requirements for personal safety, e.g. performance level c. Follow the safety instructions in the operating instructions for the device and the additional documentation! Keep these safety instructions and other documents together with the device. 1.2 Installation All installation, repair and servicing work must be carried out by qualified and trained technicians! Overview Copyright © Symeo GmbH 2012 Page 8 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 1.3 Repairs Repairs to the device must be carried out by authorized technicians. Unauthorized opening and incorrect repairs could result in severe danger to the user (danger of electric shock, radiated energy, fire hazard). 1.4 Transport and Storage Use the original packaging or other suitable packaging for returns and whenever the system is to be transported. This ensures protection from crushing, impacts, moisture and electrostatic discharge. During setup and before operation, refer to the instructions for environmental conditions included in the operating instructions for the device. Route the wires in such a way that they do not cause a hazard and are not damaged. When connecting the wires, refer to the corresponding instructions in the operating instructions for the device. Do not drop the device and do not expose it to strong vibrations. 1.5 Power Supply A safety-inspected power cable that satisfies the regulations of the country of use is required for the device. Devices with metal housings must only be connected to a grounded, shock proof socket. The device must not be operated unless the nominal voltage of the device matches the local supply voltage. Check the supply voltage of the device in stationary devices. Connecting and disconnecting wires refer to the instructions in the operating instructions for the device. Do not use any damaged wires (damaged insulation, exposed wires). A faulty wire poses a risk of electric shock or fire hazard. 1.6 Setup and Operation During installation, make sure that no objects or fluids get inside the device (risk of electric shock, short circuit). In emergencies (e. g. if there is damage to the housing, control elements or the mains cable, if fluids or foreign bodies have infiltrated the equipment), switch off the power supply to the device immediately and notify your SYMEO Service. Overview Copyright © Symeo GmbH 2012 Page 9 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Protect the contacts of all of the device's sockets and plugs from static electricity. Do not touch the contacts. If it is ever necessary to touch the contacts, take the following precautionary measures: Touch a grounded object or carry a ground strap before touching the contacts. This will divert static charges. Proper operation (in accordance with IEC60950/EN60950) of the device is only assured if the housing and integral covers for mounting slots are fully installed (electric shock, cooling, fire protection, noise suppression). If necessary, refer to the corresponding instructions in the operating instructions for the device. In the case of high outside temperatures and intense, direct solar radiation or other radiant heat, it may be necessary to provide a sun or heat shield. 1.7 System Extensions and Accessories Data links to peripheral devices must be provided with adequate shielding. For LAN cabling, the requirements in accordance with EN 50173 and EN 50174-1/2 apply. Use of either a Category 5 shielded cable for 10/100 Ethernet or Category 5e shielded cable for gigabit Ethernet is a minimum requirement. The specifications of standard ISO/IEC 11801 must be complied with. The warranty shall be voided if you cause defects to the device by installing or exchanging system extensions. 1.8 Additional Instructions regarding Compact Type and Integral Type Units The Compact type LPR® unit must not be opened except for installation. The Compact Unit contains no serviceable components. When opening, ensure that no fluid gets into the housing. When sealing the unit, ensure that the seal is included in the cover and that the Compact Unit is completely closed. Otherwise, moisture can penetrate the unit and damage it. In order to install the Integral type LPR® unit, the hood must be detached from the serviceable components. Refer also to the instructions on installing the Group Master Unit. Please take note of the safety and operating instructions in the operating instructions for the system in which you want to install the component. Overview Copyright © Symeo GmbH 2012 Page 10 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 2.1 System Description System architecture SYMEO Industrial LPR® is a system for contactless, real-time determination of distances and positions. LPR® 1D is a distance measurement system which is particularly well suited for use in very harsh, industrial environments, in which other systems such as mechanical rotary encoders or lasers cannot function for long periods. All devices have a unique identifier, via which they are actuated. In order to measure the signal transit time and thus also a corresponding distance, the two devices involved are time-synchronized (with accuracy in the picoseconds range). LPR® units use the same frequency band and the same hardware for communicating as for measuring distance. This means that no external WLAN or cable networks are needed for transmitting measurement values and other reference data. 2.2 Technical Data Overview: Technical Data Power supply 10 - 36 V DC Power consumption max. 8W Housing dimensions 260 x 160 x 91 mm (LxWxH) Weight 2.5 kg Connections Power-Supply: Terminal block Antenna: N-connector Ethernet: Plugged connection Relays (optional): Terminal block Profibus/RS232: Terminal block Antennas Up to 4 independent antennas, N-Connector Hardware interface Serial RS232, TCP/IP (optional), Profibus (optional) 7x dry contacts (optional, rating: max. 60 VDC, max. 2 A) Data interface Data port (Symeo binary protocol), Service port (ASCII protocol) Profibus (optional) User data transfer rate 8 bytes/cycle, up to 800 byte/s Frequency range 5.725 - 5.875 GHz, ISM-band System Description Copyright © Symeo GmbH 2012 Page 11 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Transmitted power *1 Output power is adjustable Max. 0.025 W EIRP Measuring distance *2 Max. 1800 m Measurement accuracy *2 Max. ±5 cm Measurement frequency *3 Max. 30 Hz Ambient temperature *4 -40 °C to +75 °C Protection class IP 65 with appropriate cable and connectors Compliance CE mark, part 15 FCC *5, RSS-210 *5 *1 Transmitted power/ field strength can be adjusted to assure that emission limits at the antenna are within legal limits, e.g. 25 mW EIRP in the EU and 50 mV/m at a distance of 3 m in the US and Canada. For FCC /IC authorization the maximum field strength is limited by firmware (FCC labeled units only). *2 Depending on the antenna type, mounting position and environment *3 For FCC/IC authorization a maximum measurement frequency of 10 Hz is allowed (FCC labeled units only). *4 Temperature inside the housing can range from -40 °C to 85 °C. *5 FCC labeled units only. 2.3 System Configuration The LPR® 1D system consists of two, three, four or five LPR® units. Each of these units can be configured either as a Group Master Unit or as a Slave Unit. A system consists of exactly one LPR® unit configured as a Group Master Unit and between one and four LPR® units configured as Slave Units. For pure 1D distance measurement two units are required and are arranged as shown in Figure 3. The distance information is available at both units. LPR 1DX System Slave Unit 1 Data in Allocate a Time Slot for Distance Measurement Group Master Unit Data in Distance Measurement Data out, i.e. PC or PLC Data Transmission (Distances, User data, etc.) Data out, i.e. PC or PLC Figure 3: 1D system System Description Copyright © Symeo GmbH 2012 Page 12 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Besides the distance information, smaller volumes of user data can also be passed between the units. These are fed in on the serial port of a unit and output in corresponding manner on the other side. Each unit consists of a basic unit, corresponding antenna cable, antenna, as well as power supply and ports. Further options for arranging LPR® units are described in the section 2.6 "Application Examples". 2.4 System Design Each LPR® 1D unit has parameters to provide an explicit allocation to a system and also to ensure the functionality of a system. These parameters are explained in the following: Parameters may only be set with the commissioning tool Symeo Wizard as described in chapter 5.4. Do not change parameters manually in the configuration files. 2.4.1 Station-ID (SID) Each unit has an explicit Identification Number in one system. If using more than one LPR® 1D systems in your environment same station numbers could be used. BUT: In one system all station numbers are different. A system consists at least of 2 units, at most of 5 units. The first unit has the station number 1 (SID 1), the second unit has the station number 2 (SID 2), etc. Unit 1 (SID 1) is the LPR® Group Master Unit, as a coordinator of the system. Units 2 – 5 (SID 2 – 5) are LPR® Slave Units. A Group Master Unit (SID 1) can only measure with a Slave Unit (SID 2 – SID 5) and vice versa, but NEVER with another Group Master Unit or a Slave Unit with another Slave Unit. But the Group Master Unit (coordinator) can measure with up to 4 Slave Units. Keep in mind: SID 1 Group Master Unit SID 2 Slave Unit 1 SID 3 Slave Unit 2 SID 4 Slave Unit 3 SID 5 Slave Unit 4 There is no difference in the hardware of a Group Master Unit and a Slave Unit. The only difference is the configuration software. The Group Master System Description Copyright © Symeo GmbH 2012 Page 13 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Unit organizes the measurements. It allocates time slots to the Slave Units to identify when these units are allowed to start with a measurement. 2.4.2 Group-ID (GID) A system is identified clearly by its group number. All units in one system have the same group number. If there is used a second, a third or more systems in your environment, all additional systems must have a different group number (see Figure 5). 2.4.3 FSK Channel (FSK) The measurement of the round trip of flight (RTOF) happens in a frequency band width of 5,725 to 5,875 GHz. In this band width the LPR® system gets a frequency channel. 30 frequency channels are available. All units in one LPR® systems have the same frequency channel. If there are more LPR® systems in your environment each further LPR® system has another frequency channel (see Figure 5). If you commission the system with the LPR® commissioning tool LPR® 1D Wizard, the frequency channel is linked to a group ID. Therefore it is really important to use different group IDs for different LPR® systems. System Number 1 Group-ID: 1 System Number 2 Group-ID: 2 Station 1 Station 2 Station 1 Station-ID: 1 Station-ID: 2 Station-ID: 1 System Number 3 Group-ID: 3 Station 2 Station-ID: 2 Station 3 Station-ID: 3 Station 4 Station-ID: 4 System Number 4 Group-ID: 4 Station 1 Station 2 Station 1 Station-ID: 1 Station-ID: 2 Station-ID: 1 Station 2 Station-ID: 2 Station 3 Station-ID: 3 Figure 4 – Example of the relation Station-ID and Group-ID System Description Copyright © Symeo GmbH 2012 Page 14 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Crane Rail SID: 2 GID: 1 Crane Bridge SID: 1 GID: 1 Radio Path SID: 3 GID: 3 Crane Crab SID: 2 GID: 3 SID: 4 GID: 2 SID: 3 GID: 2 SID: 1 GID: 3 SID: 1 GID: 2 SID: 2 GID: 2 Figure 5 – Example of multiple LPR®-systems in one crane environment 2.5 Mode of Operation of the System The distance is determined by measuring the transit time of radio signals. For this, the Group Master Unit first sends a communication packet to the Slave Unit to start the measurement. The unit that is addressed in this way sends a response sequence and a special, wideband response signal which is ideal for making distance measurements. The Group Master Unit synchronizes itself with this signal and after a precisely known time replies in highly synchronized manner with exactly the same signal. The Slave Unit receives this signal and uses the signal transit time to determine its distance from the Group Master Unit. The distance can be output after the measurement by any of the units participating. As an option, if the distance falls below a given value, a switch (dry contact) can be actuated to trigger a warning signal, for example. Besides distance measurement, the system's communication can be used for transmitting user data in the intervals between measurements. Transmission is asynchronous, i.e. the data is requested and transmitted when the measurement has been completed. To transmit data over the system, first a send data request is sent by the LPR® unit to the user. Then the user data is received and transmitted to the second LPR® unit. The data channel has a channel capacity of 8 byte/measurement cycle. This means, the overall capacity depends on the chosen measurement frequency. I.e. if a measurement frequency of 10 Hz is chosen, the capacity is 80 byte/s 2.6 Application Examples Figure 3 shows the simplest arrangement of LPR® units (LPR® 1DX). This is used for measuring the distance between two LPR® units. The abbreviation 1DX means distance measurement without positioning. Some more complex arrangements are illustrated in the following description. 2.6.1 Redundant arrangement (2 x LPR-1DX) For reasons of operational safety, it may be necessary to combine two systems in a redundant arrangement. Figure 4 shows two Slave Units and two Group Master Units installed in a redundant arrangement on two crane bridges. Each Slave Unit communicates System Description Copyright © Symeo GmbH 2012 Page 15 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation with the opposite Group Master Unit. Both systems measure independently from each other. After the measurement, the distance from the respective partner can be output at each of the participating units. Optionally, a switching contact may also be actuated depending on the distance, e.g., to trigger a warning signal for example if the crane bridges come too close to one another and there is a danger that they may collide. If more than one LPR® system is used, each system has its own group ID and its own frequency channel. So both systems do not disturb each other. 2 x LPR 1DX (Plan View) Crane Bridge 1 LPR Slave unit Antenna Radio Path LPR Group Master unit Crane Bridge 2 Figure 6: LPR® 1DX Redundant arrangement System Description Copyright © Symeo GmbH 2012 Page 16 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 2.6.2 Positioning of Crane Crab (LPR® 1DP2) In order to determine positions in two dimensions (x-y coordinates), three LPR® units can be arranged in an L-shape (see Figure 7). In this case, the unit that is configured as the Group Master Unit (unit 1) is equipped with 2 antennas. This unit measures against the first Slave Unit (unit 2) with the first antenna, and against the second Slave Unit (unit 3) with the other antenna, for example. In this way, the position of a crane crab can be determined. LPR 1DP2 (Plan View) LPR Slave Units Radio Path LPR Group Master Unit Crane Bridge Crane Crab Antenna Figure 7: LPR® 1DP2 L-shaped arrangement System Description Copyright © Symeo GmbH 2012 Page 17 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 2.6.3 Positioning of 2 Cranes on two Runways (LPR® 1DP) The Y-shaped arrangement can be used to determine the position of two cranes on different crane runways, for example. In the arrangement shown in Figure 8, the Group Master Unit (unit 1) is equipped with two antennas. A Slave Unit (unit 2 and unit 3) is installed on each of the two cranes. The two antennas are mounted at the wall at the same height as the respective Slave Units installed on the cranes. In this way, the distance of both cranes from the wall can be calculated. By comparing these two distances, a warning may be output before the two cranes cross each other‟s path, for example. LPR 1DP System Wall Kran 1 Antenna 1 Crane 1 Radio Path 1 LPR Slave Unit LPR Group Master Unit Radio Path 2 Antenna 2 Crane 2 Side View Crane 1 Crane 2 Figure 8: LPR® 1DP Y-shaped arrangement System Description Copyright © Symeo GmbH 2012 Page 18 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Hardware All corresponding installation, repair and servicing work must be carried out by qualified and trained technicians. LPR® - 1D unit (Design Compact Unit) The compact type LPR® - 1D unit is available with different interface options: Interfaces for data output : TCP/IP or Profibus or RS232 Optional: switching outputs for up to 7 relays 2 or optional 4 antenna ports The option for additional relay outputs is not provided with 4 antenna outputs. 3.1.1 Casing LPR® - 1D units are provided in die-cast aluminum housings. 26 91 160 Figure 9: LPR®-1D unit front and side view Hardware Copyright © Symeo GmbH 2012 Page 19 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Figure 10: Dimensions in mm of the LPR®-1D unit Hardware Copyright © Symeo GmbH 2012 Page 20 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 3.1.2 General internal connections Power supply Power supply (10 - 36 VDC) is connected using the power supply terminal (C1) Figure 11 depicts the pin assignment. Positve voltage can be connected either at pin 1 or 3, the negative or ground voltage is connected to pin 2. Polarity reversal or otherwise faulty connection can damage the LPR® unit. In that case the unit must be send to the SYMEO service. Figure 11 Pin assignment power supply Hardware Copyright © Symeo GmbH 2012 Page 21 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Relay connections (optional) Relays are connected using the relay terminal block (C6). Figure 12 shows the pin assignment for the seven switch relays with dry contacts. Figure 12 Relay terminal block (C6) Hardware Copyright © Symeo GmbH 2012 Page 22 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 3.2 LPR® - 1D unit with TCP/IP interface 3.2.1 Front elements The casing has cable glands for power cable (B1) and for the relays connection (B10). Figure 13 shows the front of the LPR®-1D casing in detail. Figure 13: Connections of the LPR unit with TCP/IP interface and optional relays B1: cable gland for power cable B4: antenna port 1 B5: antenna port 2 B6: pressure equalization membrane B7: two-colored LED, green = Ethernet connected / red = data transfer B8: two-colored LED, red = power supply / green = measurement activity B9 Ethernet connector B10 cable gland for relay connection cable Power supply and relay cable diameter must be within 4,5 to 10 mm, and a round cross-section. Power on is indicated with the red LED B8. Valid measurements are indicated with the green LED B8 blinking provided that the units are configured properly with the parameterization software Symeo-Wizard (see chapter 5) 3.2.2 Overview internal connectors All installation, repair and servicing work must be carried out by qualified and trained technicians! Hardware Copyright © Symeo GmbH 2012 Page 23 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Avoid entry of foreign objects or liquids into the unit. Careful mounting of the system is required. It is important that the seal remains clean and is not damaged, otherwise the protection class cannot be guaranteed. Figure 14 shows the electrical connections and switches of the LPR® unit, version TCP/IP. Figure 14 Overview electrical connections and switches C1: terminal block for power supply (10 - 36 VDC) C4: D-sub-socket for RS232 service port (not used in TCP/IP units !) C5: terminal block for RS232 service port (not used in TCP/IP units !) C6: terminal block for connection of relays S2: rotary switch for mode of operation 3.2.3 Mode of operation For standard operation of LPR® units with TCP/IP interface the rotary switch (S2) has to be set to position „3“ (see Figure 14) 3.3 LPR® - 1D unit with Profibus interface 3.3.1 Front elements The casing has cable glands for power cable (B1) and for the Profibus (B2, B3). Figure 15 shows the front of the LPR®-1D casing in detail. Hardware Copyright © Symeo GmbH 2012 Page 24 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Figure 15: Connections of the LPR® unit with Profibus interface B1: cable gland for power cable B2: cable gland for Profibus In B3: cable gland for Profibus Out B4: antenna port 1 B5: antenna port 2 B6: pressure equalization membrane B7: LED blue = Profibus error B8: two colored LED, red = power supply / green=measurement activity Power supply cable diameter must be within 4,5 to 10 mm, and a round cross-section. If the LPR unit is at the end of a Profibus, the not used cable gland has to be closed. For LPR units with Profibus interface and optional relays please use one cable for relay wiring with additional wires for power supply through cable gland B1 “Power”, see Figure 15. Power on is indicated with the red LED B8. Valid measurements are indicated with the green LED B8 blinking provided that the units are configured properly with the parameterization software Symeo-Wizard (see chapter 5) An error in the Profibus interface is indicated with the blue LED B7 Hardware Copyright © Symeo GmbH 2012 Page 25 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 3.3.2 Overview internal connectors All installation, repair and servicing work must be carried out by qualified and trained technicians! Avoid entry of foreign objects or liquids into the unit. Careful mounting of the system is required. It is important that the seal remains clean and is not damaged, otherwise the protection class cannot be guaranteed. Figure 16 shows the electrical connections and switches of the LPR unit, version Profibus. Figure 16 Overview electrical connections and switches C1: terminal block for power supply (10 - 36 VDC) C3: terminal block for connection of Profibus C4: D-sub-socket for RS232 service port C5: terminal block for connection of RS232 service port C6: terminal block for connection of relays (optional) S1: DIP-switch for termination of Profibus S2: rotary switch for mode of operation S3: DIP-switch for addressing of Profibus 3.3.3 Connection to Profibus The LPR®-Profibus interface is connected using the terminal block (C3). Hardware Copyright © Symeo GmbH 2012 Page 26 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Figure 17 shows the pin assignment for the terminal block (C3). Port „A1“ and „ A2“, also port „B1“ and „B2“ are connected inside the terminal block. In case of a removed terminal block the remaining Profibus system is still operative. The shield of the Profibus cable has to be connected to “Shield”. Figure 17 Profbus interface via terminal block 3.3.4 Connection of service port with serial interface For configuration of the LPR®-1D station the service port (C4) or (C5) is provided (RS232). For connecting to the D-sub socket (C4) please use a standard RS232 (1:1) cable with a maximum length of 2 meters. Optional the RS232 connection can be established via the terminal block (C5). The pin assignment is shown in Figure 18. The configuration of the LPR®-1D station is described in chapter 5. Hardware Copyright © Symeo GmbH 2012 Page 27 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Figure 18 Internal serial configuration port (RS232) Using the internal serial interface it is important to avoid moisture, dust or any particles into the housing during the process. 3.3.5 Termination of Profibus The Profibus system has to be terminated at the last device on the bus. DIP switch (S1) terminates the Profibus. Both switches of switch S1 has to be set to “ON” (see Figure 19) for termination. A termination applies only with connected terminal block on C3, using the on board termination with DIP switch S1. Hardware Copyright © Symeo GmbH 2012 Page 28 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Figure 19 DIP-switch for termination (S1) und addressing (S3) 3.3.6 Addressing the Profibus The address of the Profibus module is set with DIP switch (S3), see Figure 19 DIP-switch for termination (S1) und addressing (S3). DIP-switch Content 1 to 8 Binary PROFIBUS address Least significant bit (20) Most significant bit (27) Hardware Copyright © Symeo GmbH 2012 Page 29 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Example for addressing Address decimal Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6 Switch 7 Switch 8 off off off off off off off on off off off off off on off on 21 off off off on off on off on 3.3.7 Measurement frequency The maximum possible measurement frequency of 30 Hz is only available for a system with 2 stations (one distance measurement). For a system with 3 stations (two distance measurements) the maximum possible measurement frequency is 10 Hz per station. For a system with 3 stations the measurement cycle has to be configured accordingly. With the parameterization software SymeoWizard (see chapter 5) the value for the measurement cycle has to be set to minimal 100ms. The setting is shown in the menu “LPR settings”. The baud rate for the data port is set by default within the parameterization software Symeo-Wizard (see chapter 5) to a value of 19200 baud for units with Profibus interface. 3.3.8 Mode of operation For standard operation of LPR units with Profibus interface the rotary switch (S2) has to be set to position „6“ (see Figure 16). 3.4 LPR® - 1D unit with RS232 interface 3.4.1 Front elements The casing has cable glands for power cable (B1) and for the relays connection (B10). Figure 20 shows the front of the LPR-1D casing in detail. Hardware Copyright © Symeo GmbH 2012 Page 30 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Figure 20 Connections of the LPR-1D unit with RS232 interface and optional relays B1: cable gland for power cable and serial data port (RS232) B4: antenna port 1 B5: antenna port 2 B6: pressure equalization membrane B7: not used for LPR-1D units with RS232 interface B8: two-colored LED red=power supply / green=measurement activity B9 not used for RS232 version B10 cable gland for relay connection cable Power supply and relay cable diameter must be within 4,5 to 10 mm, and a round cross-section. Power on is indicated with the red LED B8. Valid measurements are indicated with the green LED B8 blinking provided that the units are configured properly with the parameterization software Symeo-Wizard (see chapter 5) 3.4.2 Overview internal connectors All installation, repair and servicing work must be carried out by qualified and trained technicians! Hardware Copyright © Symeo GmbH 2012 Page 31 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Avoid entry of foreign objects or liquids into the unit. Careful mounting of the system is required. It is important that the seal remains clean and is not damaged, otherwise the protection class cannot be guaranteed. Figure 21 shows the electrical connections and switches of the LPR unit, version RS232. Figure 21 3.4.3 Overview electrical connections and switches C1: terminal block for power supply (10 - 36 VDC) C4: D-sub-socket for RS232 service port C5: terminal block for connection of RS232 service port C6: terminal block for connection of relays (optional) S2: rotary switch for mode of operation C7: terminal block for connection of RS232 data port C8: D-sub-socket for RS232 data port Connection of service and data port with serial interface For configuration of LPR-1D units with RS232 interface the service port (C4) or (C5) is provided (RS232). For connecting to the D-sub socket (C4) please use a standard RS232 (1:1) cable with a maximum length of 2 meters. Optional the RS232 connection can be established via the terminal block (C5) for configuration with a maximum cable length of 2 meters. The pin assignment is shown in Figure 22. The configuration of the LPR-1D station is described in chapter 5 Commissioning. Hardware Copyright © Symeo GmbH 2012 Page 32 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Distance data are available on the RS232 data port (C7) or (C8). The pin assignment for (C7) is shown in Figure 22. C7 GND TX RX C8 Figure 22 Internal serial service port and data port (RS232) Using the internal serial interface it is important to avoid moisture, dust or any particles into the housing during the process. Consider the dependency of the maximum baud rate for the data port according to the cable length: 15 m: 19.200 baud 5 m: 57.600 baud < 2 m: 115.200 baud According to the cable length the baud rate for the data port at the units has to be adjusted as described in chapter 5 Commissioning. 3.4.4 Mode of operation For standard operation of LPR units with RS232 interface the rotary switch (S2) has to be set to position „0“ (see Figure 21) Hardware Copyright © Symeo GmbH 2012 Page 33 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation LPR® Antenna Types 3.5 There are different antennas that can be installed depending on the required directional characteristic. Figure 23 shows the typical LPR® antennas, which are applied in an LPR® System. For standard applications the 23dBi planar antenna is used. 6 dBi Omnidirectional Antenna -3 dB Antenna Connector Type N A = 190mm d = 20mm 30° 0 dB vertical -3 dB 10 dBi Omnidirectional Antenna Antenna Connector Type N A = 440mm d = 20mm 8,5° -3 dB 0 dB -3 dB 9° -3 dB 0 dB -3 dB vertical 23 dBi Planar Antenna Antenna Connector Type N 9° A = 305mm A B = 305mm vertical d = 25mm -3 dB 0 dB -3 dB horizontal -3 dB 12 dBi Planar Antenna (*) Antenna Connector Type SMA A = 101mm B = 80mm d = 20mm -3 dB 35° 0 dB vertical 65° 0 dB -3 dB horizontal -3 dB Hardware Copyright © Symeo GmbH 2012 Page 34 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation -3 dB 10 dBi Sector Antenna (*) -3 dB Antenna Connector Type N A = 280mm B = 125mm d = 150mm 30° 60° (optional) vertical 0 dB 160° 0 dB -3 dB -3 dB horizontal -3 dB 13 dBi Sector Antenna Antenna Connector Type N A = 500mm B = 90mm d = 80mm 5° vertical -3 dB 0 dB -3 dB 180° 0 dB horizontal -3 dB Figure 23: Example of directional characteristic of typical LPR® antennas (*) These antennas are NOT approved to be in compliance with part 15 of FCC rules and with RSS-210 of Industry Canada. Usage of these antennas may void the FCC/IC authorization to operate this equipment. Further information is found in the Appendix. Installation and exchange of antenna or antenna cables must be carried out by qualified and trained technicians! Usage of antennas or antenna cables which are not listed to be in compliance with FCC and IC rules is strictly prohibited! Hardware Copyright © Symeo GmbH 2012 Page 35 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 3.5.1 Adapter for different LPR® Antennas Depending on the required antenna, different mounting brackets are available 6 dBi and 10 dBi Omnidirectional Antenna applicable for wall and pole mounting A = 228mm B = 38mm d = 50mm 23 dBi Planar Antenna Part 1: mounting at antenna A = 115mm B = 115mm Part 2: applicable for wall and pole mounting A = 80mm B = 110mm d = 70mm applicable for pole diameter of 25mm-76mm Hardware Copyright © Symeo GmbH 2012 Page 36 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 12 dBi Planar Antenna applicable for wall mounting A = 50mm B = 44mm d = 22mm 10 dBi Sector Antenna applicable for wall and pole mounting A = 150mm B = 128mm d = 100mm 14 dBi Sektor Antenna applicable for wall and pole mounting (pole diameter 30mm -60mm) A = 410mm B = 70mm Figure 24: Available Adapters for different Antenna Types 4.1 4.1.1 Installation Installation of LPR® Unit Design Compact Unit Important Instructions for Installation During Installation, the Compact Unit has to be opened. Therefore it is important to avoid ingress of moisture, dust or any particles into the housing during the installation process. Make sure that there is enough room for the connectors, and particularly that the antenna cable is accessible; pay attention to the permitted bending radius (center of radius to cable core) for standard cables of 10,5cm (for multiple bending under mechanical load) and 4cm (unloaded and static bending). The Compact Unit should preferably be installed so that the connecting sockets point downwards. In this way, the connections are protected from rain and dust. Installation Copyright © Symeo GmbH 2012 Page 37 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 4.1.2 Installation To install the Compact Unit, you require 4 round head M6 x 30 screws (at least). Check the position of the unit on the device on which the Compact Unit is to be installed (e.g. a crane bridge). Bear in mind the installation instructions listed above. Drill holes in the device on which the Compact Unit is to be installed. Drill-hole distances: 11 cm wide, 24 cm high (see Figure 10). Open the Compact Unit: With a Phillips screwdriver (Size 0), loosen the top four screws of the Compact Unit lid. Screw the Compact Unit tightly to the device. The installation holes shown in Figure 10 are provided for this purpose. Check that the unit is mounted securely. Close the unit: Place the cover of the Compact Unit on top and fasten the cover with the four screws. Make sure that the cover is securely attached to the housing. Commission the Compact Unit (see chapter 5) 4.2 Installation of LPR® Antennas 4.2.1 Connecting and Wiring up the Antenna and Cable Connect the antennas to the antenna port at the LPR® unit. When using several antennas, ensure that they are connected to the correct ports. Group Master Slave Unit 1 Measured Antenna Antenna Distance 1 Port 1 Port 1 Measured Distance 2 (optional) Measured Distance 3 (optional) Measured Distance 4 (optional) Antenna Port 2 Antenna Port 3 Antenna Port 4 Slave Unit 2 Slave Unit 3 Slave Unit 4 Antenna Port 1 Antenna Port 1 Antenna Port 1 When installing the cable, ensure that electrostatic charging does not occur. Make sure that the cable is not kinked or trapped during installation. The minimum bending radius must always be maintained. With the standard antenna cables delivered, the minimum bending radius (center of radius to cable core) for standard cables is Installation Copyright © Symeo GmbH 2012 Page 38 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 10,5 cm (for multiple bending under mechanical load) and 4 cm (unloaded and static bending). The cable must not be attached in a way that squeezes its cross-section. On demand, cables with different flexibility characteristics are available. The antenna plug must not be removed (e.g. for installation purposes) or repaired because the specified electrical properties can only be achieved with mechanical installation assistance. When installing the antenna cable, ensure that the screw connection is seated properly and not tilt. The antenna cable plugs should be finger-tightened before tightening with an appropriate tool to no more than 1.3 Nm tightening torque. 4.2.2 Installing the Antenna(s) The line of sight between the antennas on each unit must not be obstructed. Therefore, when installing the antenna fixture, ensure that no components are blocking the line of sight between the antennas. If necessary, contact the SYMEO technical department. Depending on the antenna type used, offsetting the corresponding antennas (either vertically or horizontally) may degrade the signal strength to the point that communication is lost. Accordingly, corresponding antenna pairs should be installed with as little offset with respect to each other as possible, and preferably none. If necessary, contact the SYMEO technical department. If you change the position of one antenna, this will affect the measurement data. For installation of the planar antennas, it is important to keep the same orientation of polarization for corresponding antennas (see Figure 25). Figure 25: Backside of 23 dBi planar antenna Install the antenna bracket according to the accompanying operating instructions. Secure the antenna in the bracket. Connect the antenna to the antenna cable. Installation Copyright © Symeo GmbH 2012 Page 39 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 4.2.3 Fresnel zone The area for radio transmission between two antennas is called Fresnel zone. The main part of energy is concentrated in the first Fresnel zone. This area has to be free of any obstacles otherwise the signal is interrupted or attenuated. The first Fresnel zone can be calculated as follows: is the wave length and the distance between the two antennas. For a frequency of 5.8 GHz a wave length of approx. 0.05 m is calculated. The maximum radius between the two antennas is indicated with . For different distances the maximum radius is given in Figure 26 distance d radius b 10 m 0.36 m 50 m 0.80 m 100 m 1.14 m 250 m 1. 80 m 500 m 2.54 m 1000 m 3.60 m Fresnel zone Antenna 1 Antenna 2 Figure 26 Calculation and figure of Fresnel zone 4.2.4 Installation of Planar Antennas Each antenna type has its own opening angle. To communicate with the opposite antenna the relative antennas has to be located in the opening angles of the opposite antennas. Antennas have to be mounted without any offset (no difference in height and no offset sideways). Make sure that the opening angle is symmetric to the relative direction of motion (compare picture 1 vs. picture 2 in Figure 27). If an offset is not inevitable the antennas have to be tilted (compare picture 3 vs. picture 4 in Figure 27). Notice: If the distance goes below a fixed distance it is possible that no measurements take place any longer in this configuration. Installation Copyright © Symeo GmbH 2012 Page 40 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Figure 1 Figure 2 No Offset of Antennas No Offset of Antennas Crane Rail Crane Rail Figure 3 Figure 4 Unavoidable Offset of Antennas Unavoidable Offset of Antennas Crane Rail Crane Rail Figure 27 Antenna position with and without offset Commissioning 5.1 Requirements In order for a unit to be successfully commissioned, the LPR® components must have been installed correctly: The unit has been installed. The unit has been connected to the power supply. Antenna(s) and antenna cables for the unit have been installed. Data link has been established via TCP/IP or RS232. Once these prerequisites have been fulfilled you can connect the unit either serially to a PC or as an option (TCP/IP option) to the network and commission the LPR® 1D system. How to do this is explained in the following chapter. 5.1.1 General Commissioning is carried out via the serial service port or the TCP/IP port depending on the LPR® unit model you have: Model with TCP/IP data interface: Configuration via TCP/IP Models with Profibus or RS232 data interface: Configuration via service port C5 or C4 Commissioning Copyright © Symeo GmbH 2012 Page 41 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation LPR Unit Profibus, RS232 or TCP/IP Data Port RS232 or TCP/IP Service Port PC, PLC etc. Service PC Figure 28: LPR® Unit with Interfaces for Parameterization at Service Port and Distance Data Protocol (Binary data) at Data Port In one LPR® system all distance data (binary data/ protocol) are available at each unit. Also if you have several units in one system (crane bridge, crane crab, wall) you get the binary distance data at each LPR® unit at the data port in this system. 5.2 Connection to LPR® Unit with TCP/IP Interface With delivery the LPR® units have the fixed IP-Address 192.168.1.99, if no other IP-Address is labeled outside the LPR® unit. You can change the IP-address of the LPR® Unit via the web interface of the LPR® Unit as described in chapter 6. To get a connection between your PC and the LPR® unit it is maybe necessary to change the network parameters of your computer. Both units must be located in the same network. That means in this example that the first three numeric pads of both IP-addresses must be the same. Disconnect your PC from the network. Connect the LPR® unit and the computer with a network cable. Open your network settings of your computer. Commissioning Copyright © Symeo GmbH 2012 Page 42 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Enter the following fixed IPAddress i.e. 192.168.1.1. The subnet mask should be set to 255.255.255.0. Click in both windows OK. Figure 29 – Network Settings If you firewall settings are too restrictive, you may not get access to the LPR® unit. In this case deactivate temporarily the firewall under the tab „Advanced“ in the window LAN Properties. The LPR® Unit should be available via your PC now. You can check the connection with a „ping” to the LPR® unit: Open the Command-Window: Windows Start Button Choose Run Enter cmd and click OK Enter in the cmd.exe window: ping 192.168.1.99 or the IP-address of the LPR® unit. Figure 30 – Ping LPR® Unit The LPR® Unit should answer with a ‚Reply„. The network settings of LPR® units with TCP/IP Interface have to be set before configuration and operation. The network settings are explained in chapter 6. Commissioning Copyright © Symeo GmbH 2012 Page 43 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 5.3 Connection to LPR® Unit with serial RS232 interface or Profibus interface The RS232 service port is only available for units with RS232 or Profibus data interface. The commissioning can be done via the serial interfaces C4 (D-sub-socket) and C5 (terminal block); see Figure 31. To commission the system via the internal serial interface you must use the internal service port C5 / C4. A standard RS232 (1:1) cable of a maximum cable length of 2 m is required. The standard RS232 cable can be plugged into the D-sub-socket of service port C4. Using the internal serial interface it is important to avoid ingress of moisture, dust or any particles into the housing during the process C7 GND TX RX C8 Figure 31 Internal serial ports (RS232) C4: D-sub-socket for RS232 service port C5: terminal block for RS232 service port C7: terminal block for RS232 data port C8: D-sub-socket for RS232 data port Connect one side of RS232 cable of a cable length of 2 m with your PC and the other side with the LPR® unit (Service port C4 or C5). Check the right port of your COM-Port in the device manager of your computer. Commissioning Copyright © Symeo GmbH 2012 Page 44 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 5.4 5.4.1 Commissioning Tool – LPR® 1D Wizard Installation All files for the installation are provided on CD or USB-stick delivered together with your LPR® - 1D units. Installation can be done directly from CD or USB-stick. The files are provided in the directory “Symeo LPR 1D Wizard V4.x” ® Figure 32 – Installation directory for the LPR 1D Wizard Figure 33 – Start “setup.exe” for installation of the LPR® 1D Wizard Figure 34 – Press “Install“ for installation of the ® LPR 1D Wizard ® Figure 35 – LPR 1D Wizard starts after installation After finishing the installation process the LPR®-1D Wizard starts automatically. A shortcut was created on your desktop and you can find the Symeo LPR®-1D Wizard in your start menu. 5.4.2 Utilization of LPR® 1D Wizard The Symeo LPR®-1D Wizard provides the following functions for commissioning the LPR® 1D system: Selection of the desired application Settings of parameters for selected application General setting of LPR® 1D System (ID, Antenna and cable parameters, etc.) Connection to LPR® Units Commissioning Copyright © Symeo GmbH 2012 Page 45 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Antenna Calibration Check distance data Download of currently applied configuration files for service purposes Upload of configuration files to the LPR® -1D units for service purposes The network settings of LPR® units with TCP/IP Interface have to be set before configuration and operation. The network settings are explained in chapter 6. With the Symeo LPR® 1D Wizard you can setup LPR® 1D systems with maximal 3 units. For other applications please contact Symeo support. Start the LPR® 1D Wizard. The following window appears: Edit project All parameters and configuration files for one LPR® 1D system are handled in one project file. The format of this project file is “customers defined application name.symproj” ‚New project„ Select this button to create a new project for ® an LPR 1D System ‚Open existing project„ Select this button to open an already created ® project for an LPR 1D System Moving the cursor above a button or input field shows a tool tip. ® Figure 36 – Start LPR 1D Wizard Commissioning Copyright © Symeo GmbH 2012 Page 46 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation New project To start a new configuration push ‚New project„. Select the product family of the system used in your application. Figure 37 – New project / Select product family Open existing project If you already saved a project file you can open this project file for further settings. Push ‚Open existing project „ Select your already created project file and push ‚Open„ Figure 38 – Open existing project Select application Push ‚Edit project„. • • The first possible application is shown. You can see other application with the buttons ‚Next application„ or ‚Previous application„. Push ‚Select application„. On the right side of the window the first step to configure the settings of the selected application appears (‚Common settings„). As long as no application is selected, no step to configure the settings can be selected. Selection of application Figure 39 – Select Application Commissioning Copyright © Symeo GmbH 2012 Page 47 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Settings of LPR® System Parameters After selecting the application common settings of the LPR® system has to be entered. The ‚Common settings„ include settings for ® the complete LPR System. Fill in the input fields on the right side of the window. The fields depend on the selected application. Move the cursor above an input field to see more information about it. ® Group ID: Unique ID of the LPR system. All ® units in one LPR system have the same group ID. ® If more than one LPR system is used in your environment you have to use a different group ID for each system. The frequency channel is linked to the group ID of the system. Figure 40 – Common settings - Input fields of the ® common settings of LPR system Region / regulations: Choose the region/regulation where the system is installed. This is important to calculate the allowed transmission power, please see Appendix B in this documentation for assignment of countries and regulations. For FCC labeled units only use the setting “USA(FCC)”. For not FCC labeled units only use the setting “Europe (ETSI EN)”. Measurement cycle: Adjust the desired measurement cycle of the system. Depending on the application you should choose a minimum measurement cycle of 35 ms for 2 units or 70 ms for 3 units in one system. Push ‚Next step„. The ‚Group Master settings„ are displayed. Commissioning Copyright © Symeo GmbH 2012 Page 48 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Fill in the input fields of the ‚Group Master settings‟. Interface: The unit‟s type of data interface. Data Port rate: Transmission rate of the ® LPR system on the data port. The data rate ® for the data port can only be set for LPR units with RS 232 interface. If you change the baud rate to 9600 you should also adjust the measurement cycle of the system to values >50ms. Antenna port 1 and Antenna port 2: Settings of the antenna parameters. This is important to calculate the allowed transmission power. The number of antenna ports depends on the selected application. Antenna type: Select the type of the antenna you use. The ‚View‟ button displays a selection of available antennas. Cable type: Select the antenna cable connected to the antenna ports. Antenna port 1 is assigned to the measurement with slave unit 1. Antenna port 2 is assigned to the measurement with slave unit 2. Figure 41 – Group Master setting - Input fields of the ® Group Master settings of LPR system Push ‚Next step„. The ‚Slave 1 settings„ are displayed. ® Figure 42 – Front view Antenna ports of LPR Unit B4: antenna port 1 B5: antenna port 2 Commissioning Copyright © Symeo GmbH 2012 Page 49 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Fill in the input fields of the ‚Slave 1 settings‟ as already described in the ‚Group Master settings‟. ® For LPR System with three units the settings has also be done for the Slave 2 unit. After pushing the button ‚Next step‟ the Slave 2 settings are displayed. For Slave units only antenna port 1 is used. Figure 43 – Slave settings - Input fields of the ‚Slave ® 1 settings’ of LPR system Commissioning Copyright © Symeo GmbH 2012 Page 50 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Optional: Setting the X and Y dimensions for warning and stop areas For LPR® units with optional relays you can set the distances for warning and stop areas in this menu. Fill in the values of the warning and stop distances for your application in meters. Depending on your selected application also Y dimensions have to be set within the next menu ‚Y dimensions setting‟ after selecting ‚Next step‟. System failure timeout: Length of time without valid measurements before a system failure is indicated. Relay reenabling time: Use this value to setup hysteresis. "Open relay" is always done immediately."Close relay" can be delayed to inhibit unwanted relay toggling. This value sets the delay time. The relay will only be closed if the "Close relay" condition has been valid for this long. Figure 44 –Input fields of the ‚X dimension settings’ for warn and stop areas Commissioning Copyright © Symeo GmbH 2012 Page 51 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Optional: Usage of Relays ® If relays are used at one or more LPR unit you can allocate functionalities to each of the seven ® ® relays in the LPR unit. Each LPR unit in one system can have a different assignment of relays. You can choose between default settings, customer settings and no relay assignment. The possible functionalities of the relays depend on the application you have selected. Figure 45 – Allocation of relays Save Project The last step of the menu ‚Configuration‟ is to save all settings in one project file. Press ‚Save Now‟ and define a file name for your project. All settings and parameters of ® your LPR system is stored in this project file. Figure 46 – Save project Commissioning Copyright © Symeo GmbH 2012 Page 52 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Connection to LPR® Unit ® Having established a connection to the LPR unit as described in chapter 5.2 and 5.3 the connection can be opened by pushing the ,Connection‟ button. If you are connected to the ® LPR unit with TCP/IP interface, push ,Connect via TCP/IP‟. For serial connection push ,Connect via RS232/USB‟. ® Figure 47 – Connection to LPR unit Connect via TCP/IP: To open the TCP/IP connection you have to enter the IP-address and the port number. The service port is 3045 per default. The IP address is 192.168.1.99. IP address and TCP port can be ® changed in the web interface of the LPR unit (see chapter 6). ® Figure 48 – TCP/IP connection to LPR unit Connect via RS232/USB: To open the serial connection, select the right COM port of your computer. If you do not know the COM port, select AUTO You can control the COM port number in the device manager of your computer. ® Figure 49 –RS232/USB connection to LPR unit Once the connection is established, the following submenus appear: Unit configuration: Configure the connected unit as Group Master, Slave 1 or Slave 2. Distance Data: View the measured distance(s) Figure 50 –Submenus if connection is established Antenna calibration: Calibrate the real measured distance Commissioning Copyright © Symeo GmbH 2012 Page 53 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Extra: Download the current raw configuration file, upload an existing raw configuration file to the unit or upgrade LPR-1DXi firmware. The Extra menu is only required for service issues. Please contact Symeo service for further instructions. Unit configuration: Push ,Unit configuration‟. Select an entry from the ,Configure connected unit as‟ pull-down list. Push ,Upload Config‟ Figure 51 – Unit configuration If a new application is selected or settings are changed, you have to make an upload for each LPR® unit of one system. Display of Distance Data Click the button ‚Distance Data„. The following information is shown about the distance between Group Master and Slave1 (and optional between Group Master and Slave2): Distance The measured distance in meters. Figure 52 – Display of Distance Data Level Receive Level of the radio signal in dBm. This level depends on the distance of the two antennas. The receive level for valid measurements is in a range of -28dBm and -85dm. Measurement count The number of performed measurements Checkbox ,Distance filtering„ Only the display of the distance data is filtered for better reading. This does not affect the measurement data. Commissioning Copyright © Symeo GmbH 2012 Page 54 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Antenna Calibration After uploading all configuration files to each ® LPR unit, you have to calibrate the measured distance. Push ‚Antenna calibration„. In the field ‚Measured Distance„ the measured distance is displayed in meters, which is different to the real distance. Figure 53 – Antenna calibration Enter the real distance value between the two antennas in the field ‚Real distance„. Push ‚Calibrate„. The ,Antenna port 1‟ area relates to the distance between Group master and Slave unit 1. If you ® have a system with three LPR units with a second distance measurement then you enter the real distance value in ,Antenna port 2‟. The crane is not allowed to move during the calibration process. If the measured distance and the real distance are not the same after the calibration you might repeat the calibration. During the calibration process the antennas should have a real distance to each other of 5 to 20 m. Download Configuration Download and upload of raw configuration files is only required for service issues. All settings are already saved in your project file as described above. Push ‚Extra„. Push ,Download‟ in the ,Download configuration to raw config file‟ area. Figure 54 – Download configuration Commissioning Copyright © Symeo GmbH 2012 Page 55 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Enter the desired file name for the raw configuration file and save the file. The format of this raw configuration file is “customers defined file name.bas” The download of raw configuration files is only required for service issues. Please contact Symeo service for further instructions. Figure 55 –Enter file name Upload Configuration Pressing the button ‚Upload„ a raw configuration file can be uploaded to each ® LPR unit. Figure 56 –Upload raw configuration file Commissioning Copyright © Symeo GmbH 2012 Page 56 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Press the ‚Open„-button. The selected raw configuration file will be uploaded to the ® connected LPR unit. The upload of raw configuration files is only required for service issues. Please contact Symeo service for further instructions. Figure 57 –Upload raw configuration file Upgrade 1DXi Firmware This function is only applicable for LPR-1DXi units, please see “LPR-1DXi product documentation”. Commissioning Copyright © Symeo GmbH 2012 Page 57 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Web Server The network settings for a LPR® unit with TCP/IP interface are described in this chapter. Therefore it is necessary to open a TCP/IP connection between your computer and the LPR® unit. 6.1 Open Web Server Open your web browser. In the address bar of the web browser enter the IP-address of the LPR® unit: http://192.168.1.99. Press Enter. The IP-address of the LPR® unit is 192.168.1.99 per delivery status except another IP-address is labeled outside the box. You can establish a connection with your LPR® units Web server either via HTTP or HTTPS if the unit has been configured for this (see section "Settings", "HTTP" and "HTTPS" fields in the "Remote Access" area). In HTTP connections, the data is transmitted unencrypted. In HTTPS connections, it is encrypted for transmission (AES-256, 256-bit encryption). A connection is established with your LPR® unit. In the case of an HTTPS connection, you may see two dialog boxes. Confirm them both with OK. Then the Welcome page for the LPR® unit's Web server will appear. Click the function you want in the navigation bar. The individual functions are described in the following sections. You will be prompted to enter your information for authentication. Enter user name "symeo" and the password, and click "OK". The password has been set to "54all2u" by the manufacturer. In order to protect your system from being reconfigured by unauthorized persons, you should change this to a company password that is only provided for authorized personnel. Web Server Copyright © Symeo GmbH 2012 Page 58 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 6.2 Settings With this function you can define the network settings on your LPR® unit and the network access settings and reboot the system. Click "Settings" in the navigation bar. If you have not yet provided authentication information you will be prompted to do so now (see chapter 6.1). The Settings page for the LPR® unit's Web server is displayed. The following menu is displayed: LAN: Overview about LAN settings of LPR® unit (static or dynamic IP address) (see chapter 6.2.1) Network: Network settings (see chapter 6.2.2) Serial-to-Ethernet: Settings of service port (see chapter 6.2.3) Remote Access: (See chapter 6.2.4) Miscellaneous: Setting of time zone (see chapter 0) Special Functions: (see chapter 6.2.6) To accept the changings of the LPR® unit press button „Upload changes“. Afterwards press button “Reboot System“ to reboot the LPR® unit with the new settings. Web Server Copyright © Symeo GmbH 2012 Page 59 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 6.2.1 „LAN“ area MACAddress Unique hardware address of the LPR® unit on the LAN (Ethernet ID) (not editable) Current Mode Shows the current mode: "Static IP-Address" or "DHCP Active". In "DHCP Active" mode, the LPR® unit receives a dynamic or reserved IP address from the DHCP server. You can also ask your administrator or the SYMEO technical department about this. If the LPR® unit is set to „DHCP“ but does not get after the reboot within 60 sec an IP-address from the DHCP server the last applied fixed IP-address is used. Change Mode A button is labeled "DHCP" or "Static" depending on the "Current mode" field. Click this button to switch from "DHCP Active" mode to "Static IPAddress" mode or vice versa. IP-Address IP address of the LPR® unit Per default the IP-address is set to the static IP-address 192.168.1.99. In "DHCP Active" mode, this address is assigned by the server and cannot be edited. In "Static IP-Address" mode you can assign a fixed (static) address here. Net mask of the LPR® unit (default: 255.255.255.0) Netmask In "DHCP Active" mode, the net mask is assigned by the server and cannot be edited. Gateway IP address of the standard gateway (default: 192.168.98.254) Other LAN segments can be reached with the standard gateway. In "DHCP Active" mode this address is assigned by the server and cannot be edited. 6.2.2 „Network“ Area Hostname Hostname of the system (default: "lprb-basestation"). In "DHCP Active" mode, this hostname is also communicated to the DHCP/DNS server. A name that will be reserved on the DNS server can be entered here. You can also ask your administrator or the SYMEO technical department about this. DNS IP address of the DNS server: The DNS server is able to translate hostnames into IP addresses. In "DHCP Active" mode this address is assigned by the server and cannot Web Server Copyright © Symeo GmbH 2012 Page 60 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation be edited. Syslog IP address of the Syslog server (default: 0.0.0.0, i.e. this service has been disabled). The Syslog server is a server on the network to which it is planned to have system messages (system log) transmitted. Transmission is packet-based (UDP) and unencrypted. NTP IP address of the NTP server (default: 0.0.0.0, i.e. this service has been disabled). The NTP server is a server on the network from which the system can request the current time. 6.2.3 „Serial-to-Ethernet“ Area ttyAM1 Port number of the TCP/IP port via which the data from serial port (ttyAM1) is sent and received. ttyAM1 is the service port. (default: 3045) ttyAM2 Port number of the TCP/IP port via which the data from serial port (ttyAM2) is sent and received. ttyAM2 is the data port. (default: 3046) Per default these two ports are not enabled. Choose the Connection Type between the LPR® unit and your PC or PLC for each port. Depending on the connection you select different masks are editable. ttyAM1 / Service port Network Settings Area: IP (Server) If applying Connection Type „TCP – Connecting to Data Port using Reserve Port“ you enter here the IP-address of the server, to which the connection should be established. Data Port Port-Number of TCP/IP Port. Data of serial interface (ttyAM1) is sent and received. ttyAM1 is the service port. Default value is 3045. Reverse Port If applying Connection Type „TCP – Connecting to Data Port using Reverse Port“ you enter here the port, which the server should use for the reverse channel. Serial Settings Area Speed Baud rate of serial interface (ttyAM1). The baud rate of the service port is set to 115200 baud per default. Options Settings of serial interface ttyAM1 for the data protocol. These settings are not necessary to change and are set per default to raw –echo –ixon (Raw data, no echo, no control character). Connection Type Area Disabled The port is disabled and not reachable via TCP/IP. TCP – Listening on Data The LPR® unit is waiting for incoming connection on the Web Server Copyright © Symeo GmbH 2012 Page 61 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Port “Data Port”. If the connection is opened successful you can open the service port. TCP – Connection to Data Port using Reserve Port The LPR® unit establishes the connection to the entered server address. Setting “Random” means both communication partners arrange the reverse channel autonomously. If the connection is opened successful you get access to the service port. ttyAM2 / Data port Network Settings Area: IP (Server) For all active Connection Types the IP-address of the server is required to which the connection should be established. Data Port Port-Number of TCP/IP Port. Data of serial interface (ttyAM2) is sent and received. ttyAM2 is the data port. Default value is 3046. Reverse Port For all active Connection Types a reverse channel for data transmission is required. Serial Settings Area: Packet Filter If selected type “Fixed Frame” it is possible to filter packed data. Default value is „none”. Example: “2,3” filters the data type 0x02 (Send request) and data type 0x03 (relay switching command). Receive Size If selected type “Fixed Frame” it is possible to set the frame size of the received data packed. Example: For 1Dapplication a frame size of 15 Byte is sufficient. A smaller telegram must me filled with 0x00. Send Size If selected type “Fixed Frame” it is possible to set the frame size of the sent data packet. Example: For 1D-applicaiton a frame size of 21 Byte is sufficient. A smaller telegram is filled with 0x00 by the LPR® unit. Connection Type Area: Disabled The port is „Disabled“ and not be reachable via TCP/IP. TCP – Variable Frame – Listening on Data Port The LPR® unit is waiting for incoming connection on the “Data Port”. If the connection is opened successful you can open the data port. „Variable Frame“ means activated „Byte Stuffing“ (no fixed protocol length). TCP – Variable Frame – Connecting to Data Port The LPR® unit establishes the connection to the entered server IP-address. Setting “Random” means both communication partners arrange the reverse channel autonomously. If the connection is opened successful you get access to the data port. „Variable Frame“ means activated „Byte Stuffing“ (no fixed protocol length). TCP – Fixed Frame – The LPR® unit is waiting for incoming connection on the “Data Port”. If the connection is opened successful you can Web Server Copyright © Symeo GmbH 2012 Page 62 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Listening on Data Port open the data port. „Fixed Frame“ means deactivated „Byte Stuffing“ (fixed protocol length). TCP – Fixed Frame – Connecting to Data Port The LPR® unit establishes the connection to the entered server IP-address. Setting “Random” means both communication partners arrange the reverse channel autonomously. If the connection is opened successful you get access to the data port. „ Fixed Frame“ means deactivated „Byte Stuffing“ (fixed protocol length). UDP – Fixed Frame – Sending to Data Port The LPR® unit sends and receives data (UDP) to and from the entered server IP-address. The reverse channel uses also the data port. „Fixed Frame“ means deactivated „Byte Stuffing“ (fixed protocol length). 6.2.4 „Remote Access“ Area Telnet Click this checkbox to allow or prevent console accesses to port 23 via Telnet (checked: accesses are allowed). The port number is not editable. See also section "Extended system access". SSH/SCP/SFTP Click this checkbox to allow or prevent console accesses to port 22 via SSH (Secure SHell and data transmission via SCP (Secure CoPy) or SFTP (Secure File Transfer Protocol) (checked: accesses are allowed). The port number is not editable. See also section "Extended system access". HTTP Click this checkbox to permit or forbid accesses to the LPR® unit's Web server via HTTP (unencrypted transmission) (checked: accesses are allowed). You must also enter the corresponding port number as appropriate. The port number is set to 80 (http protocol standard) by the manufacturer. HTTPS Click this checkbox to permit or forbid accesses to the LPR® unit's Web server via HTTPS (encrypted transmission) (checked: accesses are allowed). You must also enter the corresponding port number as appropriate. The port number is set to 443 (http protocol standard) by the manufacturer. User User ID for access to the TCP/IP port. It has been set to "symeo" by the manufacturer and cannot be changed. Password Enter the new password here if you want to change the password. The password has been set to "54all2u" by the manufacturer. Repeat Password Enter the new password again here if you want to change the password. Extended system access („Remote Access“) enables console access via Telnet, SSH (Secure SHell), SCP (Secure CoPy) and via the serial port. This enables extended system information to be retrieved and troubleshooting to be carried out. We recommend that you disable all functions that are not required, see section "Settings". Web Server Copyright © Symeo GmbH 2012 Page 63 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation In extended system access, the user "SYMEO" has 'ROOT' privileges, i.e., full access to the system. Depending on the settings made, the system can also be damaged and such damage may or may not be reparable. If you have any questions, please contact the SYMEO technical department. The enormous range of functions that are available to console access means that only some can be documented here. To find out more, please contact your IT administrator or Symeo Support. 6.2.5 „Miscellaneous“ Area Timezone 6.2.6 If a NTP-server is available and the IP-address of the NTP-server is entered you can choose the time zone of the LPR® unit. It is also possible to enter the time zone manually. „Special Functions“ Area Restore default Click this button to restore the settings made by the manufacturer. Click the "Execute" button (Restore factory default settings) in the "Special functions" area to cancel all changed settings and restore the factory settings. The settings made by manufacturer are activated first after a reboot of the LPR® unit. This means that changes of the settings (i.e. IP-address) are possible. The settings affected will be deleted and populated directly with the factory settings. When the factory settings have been restored, it may be necessary to proceed as if commissioning the system again. To accept the settings the LPR® unit must be rebooted. Click this button to reboot the system. Reboot system Before you reboot the system the settings must be loaded to the LPR® unit by pressing button “Upload changes”. Download settings 6.2.7 Press the button „Download Settings“ to download a copy of the configuration as a backup. Accept settings / System Reboot As described in chapter 6.2 it is necessary to transmit the changes to the LPR® unit and afterwards reboot the unit. Web Server Copyright © Symeo GmbH 2012 Page 64 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Press button „Upload changes“ to load the changes. Scroll down to the end of the page and press „Reboot System“ to reboot the LPR® unit. Web Server Copyright © Symeo GmbH 2012 Page 65 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 6.3 System Status With this function, you can display the current system status. Click "Status" in the navigation bar. If you have not yet provided authentication information, you will be prompted to do so now (see section "Starting and using the Web server"). The Status page for the LPR® unit's Web server is displayed. The fields have the following meanings: Uptime 01:27:47 – Current system time up 20 min – Time since the last system start load average: 0.00, 0.00, 0.00 – Average system load for the last 1, 5 and 15 minutes. The load indicates how many processes are waiting to receive computing time Memory (RAM) MemTotal: Total usable working memory (physical RAM less a number of reserved bits and the kernel code) MemFree: Free working memory Filesystem Details about the active file systems and associated statistics. OS Version Operating system, kernel, compiler and compiling date SVN Version Current version of software Description Description of the system System Date Current system time Watchdog Status of the hardware watchdog, including counter of start operations since the last switch-on (connection of the power supply). A value between 2 and 127 means that the watchdog has triggered that number of system restarts. The counter is reset at 'power-on-reset' (connection of the power supply) and 'user-rest' (jumper on motherboard). In a reboot (e.g. from the Web page), the current counter status is not reset. CPU Info Serial Number: Globally unique identification number of the processor used (applied to each chip individually with a laser during production). Silicon Revision: Version of the processor used Web Server Copyright © Symeo GmbH 2012 Page 66 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 0x0 Rev. A 0x1 Rev. B 0x2 Rev. C 0x3 Rev. D0 0x4 Rev. D1 0x5 Rev. E0 0x6 Rev. E1 0x7 Rev. E2 6.4 Diagnostics Connections: State of the active and inactive connection to the LPR® unit Partitions: Size and name of available partition of non-volatile memory. The size of receive buffer (Recv-Q) and send buffer (Send-Q) should be zero if possible. A long lasting value grater zero means problems when receiving or sending data. This happens if the data cannot be readout fast enough. Example 1 – waiting for incoming connection: Proto RecvQ SendQ LocalAddress Foreign Address State tcp 0.0.0.0:3045 0.0.0.0:* LISTEN If Connection Type „TCP - Listening on Data Port“ (ttyAM1) is enabled this table shows further connection information. Proto: Protocol (TCP, UDP) Recv-Q: Number of buffered Bytes, which are received from the LPR® unit Send-Q: Number of buffered Bytes, which the LPR® unit should send Web Server Copyright © Symeo GmbH 2012 Page 67 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Local-Address: LPR® Interface address (0.0.0.0 – listening to all interfaces) Foreign Address: IP-address of opposite unit State: Status of connection Example 2: - successful established connection Proto RecvQ SendQ Local-Address Foreign Address State tcp 192.168.1.99:3045 192.168.1.1:1333 ESTABLISHED Of Connection Type „TCP - Listening on Data Port“ (ttyAM1) is enabled this table shows further connection information. Proto: Protocol (TCP, UDP) Recv-Q: Number of buffered Bytes, which are received from the LPR® unit Send-Q: Number of buffered Bytes, which the LPR® unit should send Local-Address: LPR® Interface address (192.168.1.99) with port (3045) Foreign Address: IP-address of opposite unit (192.168.1.1) with port (1333) State: Status of connection 6.5 Update Firmware With this function you can update the firmware. The firmware can be updated for example when a firmware with improved functional scope is available for the LPR® system. But the system can also be irreparably damaged by a firmware update. Please make absolutely sure that the files are correct (file names and the version has been released by SYMEO), and proceed carefully and methodically. If the firmware update has not been carried out properly, or if problems arise of the system can no longer be accessed, contact Symeo Support. For FCC/IC authorization: Only firmware delivered for the U.S./ Candian market is allowed to install. Other firmware may violate the FCC/IC authorization. Click "Firmware Update" in the navigation bar. If you have not yet provided authentication information, you will be prompted to do so now. The Firmware Update for the LPR® unit's Web server is displayed. Web Server Copyright © Symeo GmbH 2012 Page 68 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation The page Firmware Update of the WebServers of the LPR® unit is displayed. A firmware update is performed in several steps: Step 1: File system Step 2: Linux-Kernel Step 3: Optional (2D Application) Step 4: Restart Step 3 is exclusively for an update for 2D application. Otherwise this part can be skipped. 6.5.1 Step 1 – File system It is possible to make a copy of the actual firmware by downloading the firmware from the LPR® unit. Click the button „Backup ramdisk.gz“. Click the "Browse" button in the "Step 1 – flash ramdisk.gz" area. A file browser window will open. Navigate to the file you want and click "Open". Web Server Copyright © Symeo GmbH 2012 Page 69 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Click the "Upload" button in the "Step 1 – flash ramdisk.gz" area. The file has been transferred. Click the "back: Firmware Update" link. Click the "Execute" button in the "Step 1 – flash ramdisk.gz" area to transfer the file to the non-volatile memory. Web Server Copyright © Symeo GmbH 2012 Page 70 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Transfer progress is displayed in a message window. You will know when this operation is complete because a message: "... done, file ramdisk.gz removed" will be output and a link "back: Firmware Update" is provided Click the "back: Firmware Update" link. 6.5.2 Step 2 – Linux Kernel It is possible to make a copy of the actual firmware by downloading the firmware from the LPR® unit. Click the button „Backup zImage “. Click the "Browse" button in the "Step 2 – flash zImage" area. A file browser window will open. Navigate to the file you want and click "Open". Web Server Copyright © Symeo GmbH 2012 Page 71 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Click the "Upload" button in the "Step 2 – flash zImage" area. The file has been transferred. Click the "back: Firmware Update" link. Click the "Execute" button in the "Step 2 – flash zImage" area to transfer the file to the non-volatile memory. Web Server Copyright © Symeo GmbH 2012 Page 72 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Transfer progress is displayed in a message window. You will know when this operation is complete because a message: "... done, file zImage removed" will be output and a link "back: Firmware Update" is provided Click the "back: Firmware Update" link. 6.5.3 Step 3 – Optional: Userspace This step is exclusively for 2D-applications necessary and is executed the same way as described before. 6.5.4 Step 4 – Restart To complete the firmware update, you must restart the system. Web Server Copyright © Symeo GmbH 2012 Page 73 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation To do this, click the "Execute" button in the "Step 3 – Restart" button. The system will be restarted. If the new firmware contains additional configuration files the settings you made are set to factory settings. This would be also applied for the IP-address which is et the tot he default value 192.168.1.99. Symeo recommends restoring the factory settings after a firmware update and reenter the customer settings. 6.6 System Log With this function, you can display the system messages (system log). The system messages are written to a 200KB capacity memory. When the memory is full, the oldest messages are overwritten. All messages are deleted upon restart. The system messages can also be transmitted to a server on the network at the same time, see the "Syslog" field in the "Network" area in section "Settings". Web Server Copyright © Symeo GmbH 2012 Page 74 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Click "System Log" in the navigation bar. If you have not yet provided authentication information, you will be prompted to do so now (see chapter 6.1). The last 10 system messages will be displayed. The message window is updated about once per second. Web Server Copyright © Symeo GmbH 2012 Page 75 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Protocol Description Binary XP (1D messages) 7.1 General Description This protocol describes the interface between a LPR® 1D unit and the user. The binary protocol XP protocol provides information in high density. Its structure ensures a simple implementation. The transfer is done in single data frames. The interface for the binary protocol XP can either be a serial (RS232) interface or a TCP/IP or UDP interface. The baud rate of the serial interface must be set to 115200 baud. 7.1.1 Direction of Data The interface can be applied bidirectional. However, certain data types are defined for one direction. Furthermore it is only allowed to send data to a LPR® 1D unit after the LPR® 1D unit has sent a send request (type 0x02). Table 1 shows an overview which data packets can be applied in which direction. direction Data Type from LPR® 1D to LPR® 1D 0x00 Distance Data 0x01 User Data 0x02 Send Request 0x03 Relay Switching Command Tab. 1: direction of data Sending data to the LPR® 1D unit is only possible after receiving a send request (Type 0x02). The send request type guarantees the “ready-to-receive” status of the LPR® 1D unit. The LPR® 1D can only handle one data packet from one user. If nevertheless data is sent to the LPR® 1D unit without a previous send request, it can result in a reboot of the LPR® 1D unit. Per one send request the user can send only one data set to the LPR® 1D unit. 7.1.2 Structure of Data Packet To apply the protocol on a RS232 interface each data packet starts and ends with a reserved symbol. This reserved symbol cannot appear in the data stream. Figure 58 shows the general structure of the data packet. START 0x7e TYPE 1 byte 1 byte DATA CRC END 0x7f 2 byte 1 byte Figure 58: Structure of data packet Protocol Description Binary XP (1D messages) Copyright © Symeo GmbH 2012 Page 76 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation The START and the STOP-field is in each data packet the reserved symbol 0x7e and 0x7f. TYPE indicates the type of the data packet. There can be defined up to 256 different types. The TYPE-field is following the DATA-field. The DATA field contains the real data of the packet of the type TYPE. The CRC-field contains a check sum. The check sum is applied to all previous data fields except the START data field. All multi byte integers (e.g. CRC field) are encoded in Network-Byte-Order (Big Endian). All signed integers are encoded in two's complement representation. 7.1.3 Byte Stuffing The two symbols 0x7E and 0x7F are unique for START and STOP-fields. If those symbols occurs within any other field (TYPE, DATA or CRC), they must be replaced by the following order: original symbol replaced by 0x7D 0x7D 0x5D 0x7E 0x7D 0x5E 0x7F 0x7D 0x5F This byte stuffing scheme ensures that the receiver of the protocol can identify definitely the START-field within a flow of data, even if the symbol of the start field occurs within the DATA-field. Example: If the symbol 0x7d is read, it must be cancelled. The following symbol must be XOR combined with 0x20 to recreate the original symbol. Remark: Byte stuffing is deactivated for the fixed frame protocol (compare chapter 7.3). 7.1.4 CRC The CRC-16-IBM with polynomial x16+x15+x2+1 is used for the checksum CRC. The CRC is calculated over all data fields (TYPE and DATA), but not for the START and END field. The CRC-calculation is only applied to the original symbols. The appropriate calculation for coding must applied before byte stuffing. If receiving the data from the LPR® 1D system the byte stuffing must be reserved to get the original symbol. Then the CRC is updated with the original symbol. Protocol Description Binary XP (1D messages) Copyright © Symeo GmbH 2012 Page 77 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 7.2 Data Types The second byte in each data packet specifies the data type. Type 0x00 – Distance Data 7.2.1 Direction: LPR® 1D → User Content Length Data type Value START unsigned integer 0x7E TYPE unsigned integer 0x00 Source (LPR address) see chapter 7.4.1 0x#### see chapter 7.4.1 0x#### unsigned integer 0x## Distance [mm] signed integer 0x#### #### Velocity [mm/s] signed integer 0x#### #### Level [dB] signed integer 0x## Distance Error see chapter 7.4.2 0x## unsigned integer 0x00 CRC unsigned integer 0x#### END unsigned integer 0x7F ® ® Destination (LPR address) Antenna number Status Total length without byte stuffing: 21 byte ® ) Any measurement is always executed by a LPR 1D Slave Unit, this means, the Slave Unit measures its distance etc. towards a Group Master Unit. The source field always contains the address ® of the LPR 1D Slave Unit. The destination field contains the address of the measured Group Master Unit. Even if the data set is transferred further on to another unit (e.g. another Group Master Unit), the value of the source and destination field is maintained. ) The field antenna contains the antenna number of the Slave Unit as well as the antenna number of the measured Group Master Unit. The 4 lower bits represent the antenna number of the Slave Unit (values 1…4) and the higher ones the antenna number of the Group Master Unit (values 1…4). 3) reserved for future application. Currently set to 0. Example of Distance Data 7E 02 C1 81 7F 7E 00 10 03 08 02 11 00 00 10 62 00 00 00 7A E6 00 00 AF C4 7F Figure 59 - Protocol for a single 1D measurement: request data and following distance data This protocol shows a simple example for 1D measurement. A distance data set (or also 2 distance data sets) alternate with a send request. The Send Request indicates that the LPR® unit is listening to a data set from the user (for example relays external commands). The Distance Data sends the data to the user (i.e. to a PLC or to a PC/software). Protocol Description Binary XP (1D messages) Copyright © Symeo GmbH 2012 Page 78 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Send request: 7E 02 C1 81 7F 7E hex START byte 02 hex TYPE (02; Send Request) C1 81 7F hex CRC END byte hex Distance data: 7E 00 10 03 08 02 11 00 00 10 62 00 00 00 7A E6 00 00 AF C4 7F 7E hex START byte 00 hex TYPE (00: Distance Data) 10 03 hex = 00010|0000000001|1 bin 08 02 hex = 00001|0000000001|0 bin 11 = 0001|0001 hex hex = 4194 00 00 00 7A hex = 122 hex 00 hex 00 hex AF C4 7F = 230 Destination LPR® 1D address: SID: 1; GID: 1; BBt: 0 (Group Master Unit) Antenna port Slave Unit: 1 antenna port Group Master Unit: 1 bin 00 00 10 62 E6 Source LPR® 1D address: SID: 2; GID: 1; BBt: 1 (Slave Unit) Distance: 4194 mm dec Velocity: 122 mm/s dec Level: 230 – 256 = -26 dB dec Error status: 0 means no error; unequal 0 means error (see chapter 7.4.2) Status CRC hex END byte hex 7.2.2 Type 0x01 – User Data User Data can be integrated at a LPR® 1D unit via the serial interface and then transmitted to another LPR® 1D unit via the frequency channel. There the user data can be readout. Direction: LPR® 1D → User Content Length Data type Value START unsigned integer 0x7E unsigned integer 0x01 Source (LPR 1D address) see chapter 7.4.1 0x#### User Data depends on 0x#### #### #### application #### TYPE ® Protocol Description Binary XP (1D messages) Copyright © Symeo GmbH 2012 Page 79 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation CRC unsigned integer 0x#### END unsigned integer 0x7F Total length without byte stuffing: 15 byte 7.2.3 Type 0x02 – Send Request Direction: LPR® 1D → User Content Length Data type Value START unsigned integer 0x7E TYPE unsigned integer 0x02 CRC unsigned integer 0xC181 END unsigned integer 0x7F Total length without byte stuffing: 5 byte This packet is sent from the LPR® 1D unit continuously. It informs the user that the LPR® 1D unit is able to receive data from the user. The user may only send one single data frame after receiving a send request. 7.2.4 Type 0x03 – Relays Switching Command Direction: User → LPR® 1D Content Length Data type Value START unsigned integer 0x7E unsigned integer 0x03 Destination (LPR 1D address) see chapter 7.4.1 0x#### Relay Selection (Bitmask) unsigned integer 0x## Relay Switch (Bitmask) unsigned integer 0x## CRC unsigned integer 0x#### END unsigned integer 0x7F TYPE ® (bit 1..7 relay 1..7) Total length without byte stuffing: 9 byte With the relay selection (bitmask) relays are selected which can be controlled. The relays that are chosen within the Relay Selection bitmask will be switched according to the Relay Switch bitmask Example: A Relay Selection value = 0x14hex = 00010100bin and a Relay Switch value = 0xFFhex = 11111111bin will switch relays 2 and 4 ON - the state of the other relays remains unchanged. No acknowledgment of the relay switch command will be sent because this data frame can be ® forwarded to other LPR 1D units and thus no reception on the destination unit is guaranteed. In case ® of faulty data frame (e.g. invalid relays chosen or unknown destination address) the LPR 1D unit will print an error message. Protocol Description Binary XP (1D messages) Copyright © Symeo GmbH 2012 Page 80 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 7.3 TCP/IP option: Fixed Frame Protocol If the LPR® unit has a TCP/IP interface two options are available for the protocol. Either you use the protocol as it is sent from the serial interface (with different data type lengths, byte stuffing) or you use a fixed frame protocol. In the first case the data symbols 0x7e und 0x7f (which are reserved for the START and END field) are replaced (see chapter 7.1.3). Byte stuffing causes a different protocol length. For the fixed frame protocol each LPR® data packet is filled up with zero bytes to a fixed length of bytes (i.e. 87 bytes) before the data packet is sent. Byte stuffing does not occur. The START and the END byte are still used but not clear anymore due to not applying byte stuffing. The fixed length of the data packets can be set on the web-interface of the LPR® unit. For the fixed frame protocol the data packets which are sent to a LPR® unit has to be filled up to a fixed length (i.e. 15 bytes). The START- and the END byte have to be occurred as well and byte stuffing does not occur anymore. It is recommended to fill up the data packet with zero bytes to facilitate a troubleshooting. If TCP/IP is used the transmitted data have already a checksum. Therefore the checksum in the protocol is not as important as for the serial interface. Two options for the fixed frame are allowed by the protocol inverter for receiving data in a fixed frame. Either 0x0000 is sent as the check sum to the LPR® unit. Then the protocol inverter is calculating the check sum itself. Or another value (differing to 0x0000) is sent as the check sum. Then this check sum is assumed to be the correct check sum. Otherwise the data packet is rejected. 7.3.1 Detailed description TCP Fixed-Frame Protocol If a TCP fixed-frame protocol is used, a working TCP connection between the PC and the LPR® unit has to be guaranteed. Depending on the configuration of the LPR® protocol inverter either the connection to a port on the LPR® unit has to be initialized from the PC or the LPR® unit is establishing a connection to a PC. If the connection is established, the PC has to read the data from the LPR® unit in fixed data length (i.e. 87 bytes). The first byte is always the START-byte and the second byte is always the TYPE-byte. The relevance of the following data is depending on the data type. Because no byte stuffing occurs the content for a special data type is always constant. For example the measured velocity of the distance data (type 0x00) is always written in the 12.-15 data byte. Sending data from the PC to LPR® unit, a fixed data length has to be chosen (i.e. 15 byte). The first byte (START byte: 0x7e) follow the TYPE-byte. The following data depends on the chosen type, following by the CRC (correct CRC or 0x0000), following by the STOP byte (0x7f). The data packed has to be filled up with zeros. 7.3.2 Detailed description UDP Fixed-Frame Protocol If a UDP fixed frame protocol is used, the IP and the UDP port of the PC has to be configured in the LPR® protocol inverter. The converter sends each data packet as a UDP packet of a fixed length (87 byte) to the PC. Compared to the TCP fixed frame option the UDP fixed frame does not verify if the data packed arrived. The content is the same as for the TCP fixed frame protocol. Protocol Description Binary XP (1D messages) Copyright © Symeo GmbH 2012 Page 81 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation If data is sent to the LPR® unit the data has to be packed in a fixed data length (i.e. 15 bytes as for TCP fixed frame option). This data packet is sent as UDP packet to the LPR® unit. The port number of the receiver is the same as for the PC. In general bidirectional data communication is not recommended for UDP due to loosing singular data packets. 7.4 Remarks 7.4.1 LPR® 1D Address LPR® 1D unit addresses are completely defined by a 16 bit value: 15 11 10 station ID group ID BB Indicates, if the LPR® 1D unit is defined as a Slave Unit or BB – Slave Unit Bit: as a Group Master Unit (1=Slave Unit, 0=Group Master Unit) group ID: group ID of the unit (1..1022) station ID: station ID of the unit (0..30) In multi cell applications, group ID is the cell ID of the cell. 7.4.2 Distance Error codes The distance data contains an error field which indicates the status of the distance measurement. The following errors can occur: Value Content Source Description 0x00 no error 0x01 no peak detected Slave Unit No measurement signal 0x02 peak too low Slave Unit Measurement signal is imprecise 0x03 nothing received Group Master Unit No measurement data received 0x04 implausible speed Slave Unit Velocity is to high 0x05 measurement botched Slave Unit Measurement is not feasible. 0x06 no occupying received Group Master Unit 0x07 no results received Group Master Unit 0x08 trigger Group Master Unit Measurement valid Measurement channel is not reserved No measurement data received Unit did not attend the measurement Protocol Description Binary XP (1D messages) Copyright © Symeo GmbH 2012 Page 82 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Protocol Description for PROFIBUS Interface 8.1 Profibus data structure The total length of one data set is 48 bytes. The first 24 bytes presents the data for the slave unit 1 with station ID 2, the second 24 bytes presents the data for the slave unit 2 with station ID 3. Content Length Value Content Distance [mm] 0x#### #### signed integer 0x#### #### signed integer Level [dB] 0x## signed integer Error (siehe Kapitel 8.2) 0x## unsigned integer Status 0x00 unsigned integer not used 0x## unsigned integer 0x#### unsigned integer 0x#### unsigned integer Velocity [mm/s] 3) Update counter distance 1) Update counter user data 2) Station ID User data Distance [mm] 0x#### #### signed integer 0x#### #### signed integer Level [dB] 0x## signed integer Error (siehe Kapitel 8.2) 0x## unsigned integer Status 0x00 unsigned integer not used 0x## unsigned integer 0x#### unsigned integer 0x#### unsigned integer Velocity [mm/s] 3) Update counter distance 1) Update counter user data 2) User data 1) This counter is incremented when the Profibus-interface receives new data from the LPR®1D unit. In error-free operation this value is not steady. 2) This counter is incremented when the Profibus-interface receives new user data from the LPR®-1D unit. 3) The values for velocity are raw data. Velocity data are not smoothed and should only be used with following filtering. Protocol Description for PROFIBUS Interface Copyright © Symeo GmbH 2012 Page 83 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 8.2 Error messages The data packet contains an error field which indicates the status of the message. Following errors can occur: Content Source no error Description Value Measurement valid 0x00 no peak detected Slave unit No Measurement signal 0x01 peak too low Slave unit Measurement signal is imprecise 0x02 implausible speed Slave unit Velocity is to high 0x04 measurement botched Slave unit Measurement is not feasible 0x05 no valid data Profibus-Interface Profibus-Interface receives no data from LPR-1DHP unit 0xff Protocol Description for PROFIBUS Interface Copyright © Symeo GmbH 2011 Page 84 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 9 Trouble Shooting This chapter will assist you for troubleshooting. For debugging circumstances it might be helpful to install a terminal program to analyze the system. 9.1 Programs 9.1.1 Terminal Program A terminal program is useful for analyzing the system. The recommended terminal program is RealTerm. It is Open Source Software and can be downloaded from the webpage http://sourceforge.net/projects/realterm. Install the program on your PC. 9.1.2 Command Window (only for LPR unit with TCP/IP interface) The easiest way to check a connection between a LPR unit with TCP/IP interface and your PC/network is the command window. The command window is preinstalled in the operating system Windows. Click on the window button Start Run… Enter cmd and click on OK. 9.1.3 Telnet (only for LPR unit with TCP/IP interface) A short way to check the functionality of the LPR unit with TCP/IP interface is Telnet. Telnet is preinstalled in the operating system Windows. Click on the window button Start Run… Enter telnet IP-address Port and click on OK. E.g. enter telnet 192.168.1.99 3045 to open the service port of the LPR unit with IP-address 192.168.1.99 and the port 3045. 9.1.4 Browser (only for LPR unit with TCP/IP interface) A web browser is necessary to make all settings of the LPR unit with TCP/IP interface. You can make network settings as well as settings for the protocol. 9.1.5 Network Scanner (only for LPR unit with TCP/IP interface) A network scanner like the program SoftPerfect (http://www.softperfect.com/products/networkscanner/) is useful for analyzing your network. 9.2 Hardware The following additional hardware is useful: Serial Cable (1:1) less than 2 meters (for a LPR unit without TCP/IP interface ) LAN-cable (for a LPR unit with TCP/IP interface) USB -RS232 converter (if there is no RS232 serial port available at your computer) 9.3 Connection to LPR units with RS232 or Profibus interface If you have a station without TCP/IP interface connect your PC via the RS232 interface to the LPR 1D unit. For this connection you need a RS232 cable (1:1) which should be less than 2 meters long. A longer cable cannot guarantee a trouble-free transmission of data between the LPR unit and the PC. For configuration of the LPR-1D unit the service port (C4) or (C5) is provided (RS232). Trouble Shooting Copyright © Symeo GmbH 2011 Page 85 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation For connecting to the D-sub socket (C4) please use a standard RS232 cable (1:1) with a maximum length of 2 meters. Optional the RS232 connection can be established via the terminal block (C5). The pin assignment is shown in Figure 60. The configuration of the LPR-1D unit is described in chapter 5 Commissioning. The data port with binary protocol output for units without TCP/IP interface is available on Dsub socket (C8) please use a standard RS232 cable (1:1) with a maximum length of 2 meters or optional the RS232 connection can be established via the terminal block (C7). The pin assignment is shown in Figure 60. If you want to use a longer serial cable for the data port you have to reduce the baud rate of the LPR unit, as described in chapter 5. Typical values for the data rate for different length of the serial cables are: Max. baud Max. Length of RS232 rate cable 19.200 15 m 57.600 5m 115.200 <2 m C7 GND TX RX C8 Figure 60 Internal serial service port C4/C5 and data port C8/C7 (RS232) Using the internal serial interface it is important to avoid moisture, dust or any particles into the housing during the process. If you use a USB-RS232 converter make sure that all necessary drivers are installed for this hardware. Trouble Shooting Copyright © Symeo GmbH 2011 Page 86 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 9.3.1 RealTerm (for service port) With a terminal program like RealTerm you can perform more detailed analyzing of the system. Restart the LPR-1D unit before using a terminal program (power off-on) Open now the program RealTerm. In two tabs you have to change the settings: Tab Display: - Choose Display As Ansi - Extend the Rows from 16 to 30 Tab Port: - Change the Baud to 115.200 - Choose the right COM port - Click On Open Depending if you are connected to a Group Master unit or a Slave unit characters appear in the window. If you are connected to a Group Master unit a lot of “t” characters appear in case of a failure. This happens because the Group Master unit tries to make a measurement, but output a failure because the opposite station is not available or connected. “t” means failure of measurement. A working system should output “m” characters. “m” means a working measurement. If you are connected to a Slave unit only “m” characters are shown for a working system. In case of a failure nothing is shown when connected to a Slave unit. 9.4 Connection to the LPR unit with TCP/IP interface If you have a station with TCP/IP interface you only can connect your PC via the TCP/IP interface to the LPR unit. For the connection you need an Ethernet cable. Trouble Shooting Copyright © Symeo GmbH 2011 Page 87 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation The IP-address is set to the fixed IP address 192.168.1.99 when delivering the system to the customer. To get access to the station you need to set your PC in the network as the LPR unit. 9.4.1 LAN Settings of your PC First you need to disconnect your PC from your network to avoid trouble when changing the IP address of your computer. Now you connect the LPR unit via an Ethernet cable with your PC. If you are not in the same net as the LPR unit you have to change temporary the network settings of your PC. Both IP-addresses must be in the same network, i.e. the first three fields of the IP-address must match. Open your network connection and set a fixed IP address to your computer, i.e. 192.168.1.1. The subnet mask should be set to 255.255.255.0. Click in both windows “OK”. If your firewall is enabled and set to restrictive, it might happen that you cannot access the LPR unit. In this case disable the firewall settings temporary in the tab Advanced in the window Network properties. 9.4.2 Check TCP/IP connection The first way to check the IP-connection from your computer to the LPR unit is to “ping” the LPR unit. Open the command window (Window button Start Run Enter cmd and click on OK). Enter in the window 192.168.1.99 –t and click Enter. Trouble Shooting Copyright © Symeo GmbH 2011 Page 88 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation You should get a reply from the LPR unit with the fixed IP-address 192.168.1.99 If the connection failed probably your firewall settings of your PC are set to restrictive or the IP-address of the LPR unit is probably not 192.168.1.99. Please check the settings. Compare also the hint in chapter 9.4.1. If you have changed the IP address without bearing in mind the IP address the IP-address could be detected with the program NetworkScanner. 9.4.3 RealTerm (for service port) With a terminal program like RealTerm you can perform more detailed analyzing of the system. Restart the LPR-1D unit before using a terminal program (power off-on) Open now the program RealTerm. In two tabs you have to change the settings: Tab Display: - Choose Display As Ansi - Extend the Rows from 16 to 30 Trouble Shooting Copyright © Symeo GmbH 2011 Page 89 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Tab Port: - Enter the IP-address of the LPR unit and the port: IP-address:port - I.e.: 192.168.1.99:3045 - Click on WinSock is RAW - Open the connection Depending if you are connected to a Group Master unit or a Slave unit characters appear in the window. If you are connected to a Group Master unit a lot of “t” characters appear in case of a failure. This happens because the Group Master unit tries to make a measurement, but outputs a failure because the opposite station is not available/ connected. “t” means failure of measurement. A working system should output “m” characters. “m” means a working measurement. If you are connected to a Slave unit only “m” characters are shown for a working system. In case of a failure nothing is shown when connected to a Slave unit. If you do not get access to the LPR unit check if the port is open. The port for the service port is 3045 per default. But it might be possible that you have changed it or did not open it (see chapter 9.4.4). 9.4.4 Web Interface If you can “ping” the IP-address of the LPR unit but do not get data (either via the service port or the data port or both ports) you have to check the settings on the web page of the LPR unit. Open a web browser and enter the IP-address of the LPR unit (i.e. http://192.168.1.99). You get access to the LPR unit. If you are connected via HTTPS-connection, it might appear to dialogue boxes which you have to confirm with “OK”. You see the Start-page of the LPR unit. Trouble Shooting Copyright © Symeo GmbH 2011 Page 90 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Click on Settings. You have to authorize yourself. Enter the username „symeo“ and the password and click „OK“. The password is per default „54all2u“. The Settings page of the Web-interface of the LPR unit looks like the following. Scroll down to the section: Serial-to-Ethernet: Here you enter the connection type for the service port (ttyAM1) and the data port (ttyAM2). Both ports should be not disabled. Choose the right connection type and enter the data port. The data port is per default 3045 for the service port and 3046 for the data port. If you have made changes click on “Upload changes” and then on “Reboot system”. After the reboot try again to get access to the LPR unit as described in chapter 9.4.3. Trouble Shooting Copyright © Symeo GmbH 2011 Page 91 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 9.5 No Measurements With the configuration tool Symeo Wizard you can check the functionality of your system when connected to the service port as described in chapter 5. If this is working you also can check the data port output for LPR-1D units with TCP/IP or RS232 interface using RealTerm to display. For LPR-1D units with TCP/IP or RS232 interface the data port provides the binary protocol as described in chapter 7. Check List: 1) The antennas are connected to the right port of the LPR 1D unit. measurement 1 measurement 2 (optional) Group Master unit Antenna at Port 1 Slave unit 1 Antenna at Port 1 Antenna at Port 2 Slave unit 2 Antenna at Port 2) If you use planar antennas the orientation of the antenna must be correct. A small label on the backside of the antenna indicates the horizontal and vertical alignment. 3) For a distance measurement always two stations are involved. It has to be a Group Master unit and a Slave unit. Make sure that never two Slave units or two Group Master units are measuring with each other. 4) Units are powered with correct voltage and the LEDs on the front of the units lighting as described in chapter 3 5) Check if the rotary switch S2 is set correctly: position „0“: RS232 position „3“:TCP/IP position „6“: Profibus 6) For LPR-1D units with TCP/IP interface all settings have been made in the WEB server according to chapter 6.2. 7) Units are properly configured with Symeo Wizard as described in chapter 5. 8) Distance data are displayed in Symeo Wizard, see chapter 5.4.2. If not try to overwrite the configuration with the program LPR 1D wizard for all stations again. 9) Check the data port is working. Open the program RealTerm. If connected to a LPR unit with TCP/IP interface open the data port 3046: Enter 192.168.1.99:3046. The display in RealTerm should be set to Hex[space] to “see” binary data. If you use a LPR unit with RS232 interface connect the serial cable to the data port C8, see Figure 60. An example of the binary protocol output at the data port is shown below. Trouble Shooting Copyright © Symeo GmbH 2011 Page 92 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Example for a binary protocol output at the data port Trouble Shooting Copyright © Symeo GmbH 2011 Page 93 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 10 Appendix A: Agency certifications For FCC versions only! United States (FCC) and Canada (Industry Canada) Radiofrequency radiation exposure Information: This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Changes or modifications made to this equipment not expressly approved by SYMEO GmbH may void the FCC/IC authorization to operate this equipment. This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: this device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. A direct connection between the external power supply unit and AC power line is strictly prohibited. A line filter (e.g. EPCOS B84113-C-B30 or similar characteristics) shall be used to connect the power supply unit and AC power line. Installation: All installation, repair and servicing work must be carried out by qualified and trained technicians! Repairs: Repairs to the device must be carried out by authorized technicians. Unauthorized opening and incorrect repairs could result in severe danger to the user (danger of electric shock, radiated energy, fire hazard). United States (FCC) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Appendix A: Agency certifications Copyright © Symeo GmbH 2011 Page 94 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help This device has been designed to operate with the antennas listed below. Antennas not included in this list are strictly prohibited for use with this device. Only antenna cables delivered by Symeo are allowed to use. Usage of other antenna cables may void the FCC authorization to operate this equipment. 6 dBi Omnidirectional Antenna -3 dB Antenna Connector Type N A = 190mm d = 20mm 30° 0 dB vertical -3 dB 10 dBi Omnidirectional Antenna Antenna Connector Type N A = 440mm d = 20mm 8,5° -3 dB 0 dB -3 dB 9° -3 dB 0 dB -3 dB vertical 23 dBi Planar Antenna Antenna Connector Type N 9° A = 305mm A B = 305mm vertical d = 25mm -3 dB 0 dB -3 dB horizontal 13 dBi Sector Antenna -3 dB Antenna Connector Type N A = 500mm B = 90mm d = 80mm 5° vertical -3 dB 0 dB -3 dB 180° 0 dB horizontal -3 dB Figure 61: LPR® 1D antenna Appendix A: Agency certifications Copyright © Symeo GmbH 2012 Page 95 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation Canada (Industry Canada) This Class [B] digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe [B] est conforme à la norme NMB-003 du Canada. This device has been designed to operate with the antennas listed below and having a maximum gain of 23 dBi. Antennas not included in this list or having a gain greater than 23 dBi are strictly prohibited. The required impedance for antenna and antenna cable is 50 ohms. Only antenna cables delivered by Symeo are allowed to use. Usage of other antenna cables may void the IC authorization to operate this equipment. 6 dBi Omnidirectional Antenna -3 dB Antenna Connector Type N A = 190mm d = 20mm 30° 0 dB vertical -3 dB 10 dBi Omnidirectional Antenna Antenna Connector Type N A = 440mm d = 20mm 8,5° -3 dB 0 dB -3 dB 9° -3 dB 0 dB -3 dB vertical 23 dBi Planar Antenna Antenna Connector Type N 9° A = 305mm A B = 305mm vertical d = 25mm -3 dB 0 dB -3 dB horizontal 13 dBi Sector Antenna -3 dB Antenna Connector Type N A = 500mm B = 90mm d = 80mm 5° vertical -3 dB 0 dB -3 dB 180° 0 dB horizontal -3 dB ® Figure 62: LPR 1D antenna Appendix A: Agency certifications Copyright © Symeo GmbH 2012 Page 96 of 97 SYMEO Local Positioning Radar System ® LPR -1D Product Documentation 11 Appendix B: Table of countries and regulations Country Regulation setting in Wizard Australia/New Zealand ETSI EN Brazil FCC Canada FCC China (*) Setting for China Europe ETSI EN India ETSI EN Malaysia ETSI EN Republic of South Africa ETSI EN Russia ETSI EN Singapore ETSI EN Taiwan ETSI EN Turkey ETSI EN USA FCC (*) not yet implemented, will follow in next update of Symeo Wizard For countries not listed above please contact Symeo for further information. Observe the regional-specific regulations and mandatory permissions to operate LPR-1D systems in the respective countries. Please contact Symeo for further clarification. Appendix B: Table of countries and regulations Copyright © Symeo GmbH 2012 Page 97 of 97
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 97 Language : en-US Producer : Microsoft® Office Word 2007 Creator : Microsoft® Office Word 2007 Create Date : 2012:03:15 16:13:35 Modify Date : 2012:03:15 16:13:35EXIF Metadata provided by EXIF.tools