Synapse Electronique ZW01UL Wireless communcation module User Manual

Synapse Electronique Wireless communcation module Users Manual

Users Manual

SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.1/19Z‐WaveRadioModule1.1 TECHNICALSUMMARY FCCcertification:Limitedmodular FLiRS1mode:lowconsumptionoperation UARTcommunication:115,200bps Z‐Wavesoftwareprotocolstackincluded IntegratedPCBantenna Outputpower:‐4dBm CompactPCBfootprint:41x32mm Basedonan8051CPUcore Power‐On‐Reset/Brown‐Outdetection TXmode:typicalcurrent32mAat‐4dBm RXmode:typicalcurrent32mA Normalmode:typicalcurrent15mA Sleepmode:typicalcurrent1µA1.2 APPLICATIONS Z‐Waveslaveandenhancedslavemodules HVACthermostat Lightswitch‐dimmer Energymeasurementdevice Securitysystems Sensornetworks Remotecontrolofhouseholdappliances Audioandvideomanagement1.3 DESCRIPTIONTheSYN‐RF‐ZW01UxseriesofmodulesintegratesaPCBantennaandamicrocontrollerwithRFtransmitter‐receiver(ZM5202).Anoptionalexternalnon‐volatilememorycanbeaddedaccordingtotheZ‐Wavesoftwarestackvariantincludedinthemodule.Thelimitedmodularcertificationallowstheintegrationofthemoduleinacompatibleproductwithoutrequiringcertifyingthefinalproduct.Toensureareliablecommunication,thepatentedZ‐Waveprotocolsupportsautomaticretransmissions,collisionavoidancemechanisms,frameacknowledgement,CRCs,frequencyagility,andmeshrouting.1.4 CERTIFICATIONLimitedmodularcertification MODEL:SYN‐RF‐ZW01Ux‐L FCCID:OW7‐ZW01L IC:10525A‐ZW01UL1TousethemoduleinFLiRSmode,pleaserefertotheSigmaDesigndocumentation.
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.2/19TABLEOFCONTENT1.1TECHNICALSUMMARY.............................................................................................................................................................11.2APPLICATIONS..........................................................................................................................................................................11.3DESCRIPTION............................................................................................................................................................................11.4CERTIFICATION.........................................................................................................................................................................12Nomenclature...............................................................................................................................................................................33FUNCTIONALBLOCKDIAGRAM....................................................................................................................................................34PINMAP........................................................................................................................................................................................45ELECTRICSPECIFICATIONS............................................................................................................................................................55.1Absolutemaximalratings.........................................................................................................................................................55.2Recommendedoperatingconditions.......................................................................................................................................55.3Electricalspecifications............................................................................................................................................................55.4Radiospecifications(RF)...........................................................................................................................................................65.5Resettingthemodule...............................................................................................................................................................65.6Unusedpins..............................................................................................................................................................................75.7Modulecommunication...........................................................................................................................................................76EXTERNALNON‐VOLATILEMEMORY(Flash)................................................................................................................................87INTEGRATIONGUIDELINES.........................................................................................................................................................107.1Environmentalconsiderations................................................................................................................................................107.2Soldering.................................................................................................................................................................................107.3Connectiondiagramexamples...............................................................................................................................................118Mechanicinformation................................................................................................................................................................128.1PCBfootprint..........................................................................................................................................................................128.2Moduledimensions................................................................................................................................................................139FCCComplianceStatement........................................................................................................................................................1410ICComplianceStatement...........................................................................................................................................................1511ModificationHISTORY.................................................................................................................................................................16ANNEXES..................................................................................................................................................................................................171INTEGRATIONconsiderationsfortheSTE402NP+thermostat...................................................................................................181.1Mechanicconsiderations........................................................................................................................................................181.2PCBintegrationconsiderations..............................................................................................................................................182integrationconsiderationsintheSTE‐CIR034heatingConvector..............................................................................................192.1Mechanicconsiderations........................................................................................................................................................192.2PCBintegrationconsiderations..............................................................................................................................................19
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.3/192 NOMENCLATURESYN‐RF‐ ZW01URS‐ L123451. Functionality SYN‐RF:Radioproduct2. Series ZW01:Z‐Waveprotocol,series013. Zone U:US/CANzone(908MHz)4. Softwarestack RS:Routingslave ES:Enhancedroutingslave5. Option L:LimitedmodularcertificationModelDescriptionZone*SYN‐RF‐ZW01URS‐LZ‐Waveradiomodule–routingslavesoftwareconfigurationUSYN‐RF‐ZW01UES‐LZ‐Waveradiomodule–enhancedroutingslavesoftwareconfigurationUTable1–Availableoptions3 FUNCTIONALBLOCKDIAGRAMFigure1–Blockdiagram‐SYN‐RF‐ZW01Uxmodule
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.4/194 PINMAPFigure2–PinmapPin#NameMCUPinTypeDescription1RESET_NRESETfunctionisactiveonlowlevel–defaultto ahighlevelvia a10KOhmpull‐upresistorembeddedinthemodule2GND1 GND Powersupplyandcircuitground3NVM_SCKP2.4/SPI1_SCKSPIserialmemory port–Dataclocksignal4NVM_MOSIP2.2/SPI1_MOSISPIserialmemoryport–Datasignal,module toexternalmemory5NVM_MISOP2.3/SPI1_MISOSPIserialmemory port–Datasignal,externalmemorytomodule6NVM_CSP0.4I/O SPIserialmemory port–Memoryselection(enable)7GND2  GND Powersupplyandcircuitground8UART_B2RFP3.4/UART0_RXUARTserialcommunicationport–Datasignal,mastertomodule9UART_RF2BP3.5/UART0_TXUARTserialcommunicationport–Datasignal,moduletomaster10GND3 GND Powersupplyandcircuitground11VCC  VCC Power rail12GND4 GND Powersupplyandcircuitground13GND5  GND Powersupply andcircuitground14GND6 GND PowersupplyandcircuitgroundTable2‐Pinmap
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.5/195 ELECTRICSPECIFICATIONS5.1 AbsolutemaximalratingsSymbolSettingsMinTypicalMaxUnitsVDD‐GNDSupplyvoltage3.2‐ 6VDCVIN‐GNDVoltageappliedonaninput‐0.5‐ 6VDCTSTORStoragetemperature‐55‐ 85°CTAMBOperatingambienttemperature‐40‐ 85°CTable3–Absolutemaximalratings25.2 RecommendedoperatingconditionsSymbolSettingsMinTypicalMaxUnitsVDD‐GNDSupplyvoltage3.3‐ 5.5VDCVIN‐GNDVoltageappliedonaninput0‐5.5VDCVRIPPLEMaximumsupplyvoltageripple‐ ‐ 0.1∆VTAMBOperatingambienttemperature‐102580°CTable4–Recommendedoperatingconditions5.3 ElectricalspecificationsSymbolParameterMinTypicalMaxUnitsVIHHigh‐levelthresholdvoltage,digitalinput2.2‐ ‐ VVILLow‐levelthresholdvoltage,digitalinput‐‐0.6VVIL_RESETLow‐levelthresholdvoltage,RESET_Ninput‐ ‐ 0.9VIILLeakagecurrent,anydigitalinput‐‐10µAPUINInternalpull‐upresistor,anydigitalinputexceptRESET_N15‐ 20kΩPUIN_RESETInternalpull‐upresistor,RESET_Ninput9.910.010.1kΩVOHHigh‐levelvoltage,digitaloutputport2.43.03.06VVOLLow‐levelvoltage,digitaloutputport‐‐0.4VIOMaximumcurrent,digitaloutputport‐ ‐ 6mAIDD_ACTIVESupplycurrent,processorclockedat32MHz‐14.915.9mAIDD_RXSupplycurrent,Z‐Wavereceiving‐ 32.435.1mAIDD_TX_‐4Supplycurrent,Z‐Wavtransmissionat‐4dBm‐32‐mAIDD_SLEEPSupplycurrent,sleepmode,wake‐uptimerinactive‐ 1‐ µAIDD_WUTSupplycurrent,sleepmode,wake‐uptimeractive‐2‐µATable5–Electricalspecifications2Theabsolutemaximalcharacteristicsmustnotbeexceededunderanycircumstance.Exceedingtheselimitscouldcausepermanentdamagetothemodule.
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.6/195.4 Radiospecifications(RF)Datarate9.6kbps40kbps100kbpsZoneModulationFSKFSKGFSK FrequencydeviationFC±20kHzFC±20kHzFC±29.3kHz Channelbandwidth90kHz90kHz110kHz EncodingManchesterencodedNRZNRZ Frequency(Canada/US)908.42MHz908.40MHz916MHzUTable6–Z‐WaveradiofrequencyspecificationsSymbolSettingsMinTypicalMaxUnitsP9.6Sensibilityat9.6kbps‐ ‐102.7‐101.0dBmP40Sensibilityat40kbps‐ ‐99.0‐97.2dBmP100Sensibilityat100kbps‐ ‐93.0‐91.8dBmTable7–Receiversensibility(excludingtheantenna)SymbolSettingsMinTypicalMaxUnitsPRFCurrenttransmitterpower(RFPOW=17,0x11)‐ ‐4‐ dBmPH2Secondharmonic(RFPOW=20(‐3dBm))‐‐59.6‐ dBcPH3Thirdharmonic(RFPOW=20(‐3dBm))‐ ‐47.6‐ dBcPN30kHzPhasenoiseat30kHz‐ ‐88.1‐dBc/HzPN100kHzPhasenoiseat100kHz‐ ‐95.2‐ dBc/HzPN1MHzPhasenoiseat1MHz‐ ‐107.3‐dBc/HzPN10MHzPhasenoiseat10MHz‐ ‐113.1‐ dBc/HzPN100MHzPhasenoiseat100MHz‐ ‐113.8‐dBc/HzTable8–Transmitterperformances(excludingtheantenna)5.5 ResettingthemoduleThemoduleisresetbypulsingtheRESET_Ninputlowonetime,aspertheTReset_LspecificationinTable9.Tokeepthemodulein'reset',theRESET_NinputmustbecontinuouslypulsedasperthespecificationsinTable9.SymbolSettings MinTypicalMax UnitsTReset_LHoldtime,RESET_Nlow3‐ 4,000usTReset_HHoldtime,RESET_Nhigh2‐4usTReset_PUMaximumtimeafteraresettoreturninactivemodeandbereadytoexecutethesoftware‐ ‐ 1msTable9–ResetmodeFigure3–PulsingtheRESET_NinputtomaintaintheresetmodeTReset_LTReset_H
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.7/19TheRESET_Ninputofthemodulemustbedrivenbyanopencollectorcircuit.Drivingthisinputwithapush‐pullcircuitcoulddamagethemodule.TheRESET_Ninputintegratesapull‐upresistortomaintainthisinputhighwhennotdriven.Donotaddanyexternalfilteronthisport;themodulealreadyincludesafilter.5.6 UnusedpinsAllunusedpinsmustbeleftunconnected.Theredefaultlevelisinternallyfixedat3.0Vtypicalonthemodule.TheonlyexceptionistheMISOinputportthatmustbeconnectedtoGNDwhenunused5.7 ModulecommunicationThecommunicationwiththemoduleisperformedviatheserialUART(UniversalAsynchronousReceiver/Transmitter),usingtheUART_RF2BandUART_B2RFports.TheUARToperatingspecificationsmustbeconfiguredasperTable10andFigure4.Settings ValueBitspersecond115200Databits8ParitynonStopbit1FlowcontrolnonTable10–UARTconfigurationsettingsFigure4–UARTcommunicationwaveform
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.8/196 EXTERNALNON‐VOLATILEMEMORY(FLASH)DependingontheZ‐Wavenetworktypedesired,themodulemayrequireanexternalmemorytooperate.CodeSoftwarestackExternalmemoryneededRSRoutingSlaveNoESEnhancedRoutingSlaveYesTable11–ExternalmemoryrequirementInthecaseofanenhancedroutingslaveapplication,thememoryneededshallmeetthefollowingrequirements:SettingsValueSize1MbitsSPImodessupported(CPOL=0,SPHA=0)&(CPOL=1,CPHA=1)SPIclockfrequency4MHzPageWritesize256BytesPageErasesize256BytesSoftwareprotectionYesPageRead85µsPageWritecycle25msEndurance100000cyclestypicalDataRetention>20yearsTemperature‐40°Cto85°CTable12–SerialFlashmemoryspecificationsCommandOpcodeDescriptionWREN0x06WriteEnableWRDI0x04WriteDisableRDID0x9FReadIdentificationRDSR0x05ReadStatusRegisterWRSR0x01WriteStatusRegisterREAD0x03ReadDataBytesFAST_READ0x0BReadDataBytesatHigherSpeedPW0x0APageWrite(256B)PP0x02PageProgramPE0xDBPageErase(256B)SSE0x20Sub‐SectorEraseSE0xD8SectorEraseBE0xC7BulkEraseDP0xB9DeepPower‐downRDP0xABReleasefromDeepPower‐downTable13–Flashmemoryinstructions
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.9/19BitNameDescription7SRWDStatusRegisterWriteDisable6,5,4XUndefined3BP1BlockProtect12BP0BlockProtect01WELWriteEnableLatch0WIPWriteinProgressTable14–FlashmemorystatusregistersSynapseElectronicsrecommendsthefollowingmemorymodelthatmeetstherequirements.TypeManufacturer Partnumber MemoryspaceFlashMicronTechnologyM25PE20256kBTable15–Externalmemoryrecommended
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.10/197 INTEGRATIONGUIDELINESTheSYN‐RF‐ZM01Uxisasurfacemountmodule.ItsshapeanddimensionsareillustratedinFigure8.ThePCBhasathicknessof1.6mmandaninterconnectionfootprintofcastellationtype.Figure7illustratestherecommendedPCBfootprint.APCBantennaisintegratedonthemodule.ThegroundplaneofthemasterPCB(receivingthemodule)actsasacounterbalanceforthePCBantenna.Thegroundplane’sdimensionshaveamajorimpactontheantennaperformance.ItisrecommendedtomaximizethesurfaceofthisgroundplaneonthemasterPCB.AllGNDpinsshallbedirectlyconnectedtothegroundplaneofthemasterPCB.Ifthermal‐reliefconnexionviasareused,thecombinedwidthshallbenolessthan0.5mm.7.1 EnvironmentalconsiderationsTheradioperformancesofthemodulearegreatlyaffectedbyitsenvironment.Theannexesattheendofthisdocumentprovideguidelinestointegratethemoduleindifferentmasterproducts.Theintegrationofthismoduleinproductsotherthantheonespresentedwouldrequirecarefulverificationoftheradioperformancesandcharacterization.7.2 SolderingThemodulemustbehandsoldered.Ithasnotbeendesignedforreflowsoldering,asitcouldresultinapermanentdamageofthemodule.
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.11/197.3 ConnectiondiagramexamplesFigure5–ConnectionwithoutexternalmemoryFigure6–Connectionwithexternalmemory3.3VUART_B2RFUART_RF2BRESET_NC11 uFU1SYN-RF-ZM01xxRESET_N1UART_B2RF8UART_RF2B9VDD 11GND1 2GND2 7GND3 10GND4 12GND5 13GND6 14NVM_SCK3NVM_MOSI4NVM_MISO5NVM_CS63.3VUART_B2RFUART_RF2BRESET_NC11 uFU1SYN-RF-ZM01xxRESET_N1UART_B2RF8UART_RF2B9VDD 11GND1 2GND2 7GND3 10GND4 12GND5 13GND6 14NVM_SCK3NVM_MOSI4NVM_MISO5NVM_CS6C2R1 R2U2External NVMCS#1HOLD#7SI/SIO05SCLK6VCC8GND4SO/SIO12WP#33.3V
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.12/198 MECHANICINFORMATION8.1 PCBfootprintFigure7–RecommendedPCBfootprintNotes:1. Dimensionsareinmm;2. NomaterialmustbeinthePCBkeep‐outzone,includingFR4dielectric.PerformanopeninginthemasterPCB,orplacethemoduleinperiphery,withthekeep‐outzonelyingoutsidethemasterPCB;3. Themoduleincludesviasonitsbottomlayer,facingthemasterPCB.MakesurethatthereisnoconductivematerialexposedonthemasterPCB,underthemodule.ExposedconductivematerialcouldcauseashortcircuitonthemoduleorthemasterPCB,andpotentiallydamagethem.Thesolderjointbetweenthemodule'scastellatedpadsandthemasterPCBpadsshallmeettheappropriateIPCrequirements.Pleaserefertothedocument'IPC‐A‐610AcceptabilityofElectronicAssemblies',section8.2.4CastellatedTerminations.
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.13/198.2 ModuledimensionsFigure8–ModuledimensionsinmmNote:TheshieldingboxisnotincludedintheSYN‐RF‐ZW01Ux‐Lversions.
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.14/199 FCCCOMPLIANCESTATEMENTFCCWarningNOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures: Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp.CautionThisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:1. Thisdevicemaynotcauseharmfulinterference,and2. Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser'sauthoritytooperatetheequipment.
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.15/1910 ICCOMPLIANCESTATEMENTThisdevicecomplieswithIndustryCanadalicense‐exemptRSSstandard(s).Operationissubjecttothefollowingtwoconditions:1. Thisdevicemaynotcauseinterference,and;2. Thisdevicemustacceptanyinterference,includinginterferencethatmaycauseundesiredoperationofthedevice.LeprésentappareilestconformeauxCNRd'IndustrieCanadaapplicablesauxappareilsradioexemptsdelicence.L'exploitationestautoriséeauxdeuxconditionssuivantes:1. L'appareilnedoitpasproduiredebrouillage,et;2. L'utilisateurdel'appareildoitacceptertoutbrouillageradioélectriquesubi,mêmesilebrouillageestsusceptibled'encompromettrelefonctionnement.UnderIndustryCanadaregulations,thisradiotransmittermayonlyoperateusinganantennaofatypeandmaximum(orlesser)gainapprovedforthetransmitterbyIndustryCanada.Toreducepotentialradiointerferencetootherusers,theantennatypeanditsgainshouldbesochosenthattheequivalentisotropicallyradiatedpower(e.i.r.p.)isnotmorethanthatnecessaryforsuccessfulcommunication.Conformémentàlaréglementationd'IndustrieCanada,leprésentémetteurradiopeutfonctionneravecuneantenned'untypeetd'ungainmaximal(ouinférieur)approuvépourl'émetteurparIndustrieCanada.Danslebutderéduirelesrisquesdebrouillageradioélectriqueàl'intentiondesautresutilisateurs,ilfautchoisirletyped'antenneetsongaindesortequelapuissanceisotroperayonnéeéquivalente(p.i.r.e.)nedépassepasl'intensiténécessaireàl'établissementd'unecommunicationsatisfaisante.
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.16/1911 MODIFICATIONHISTORYRev.DateDescription0January2015Initialrelease1April2015Globalupdatefollowingthemodulerevision2September2015Officialrelease–Certificationinformationadded3September2015Regulatory–FCC&IC–StatementaddedTable16–ModificationhistorySynapseÉlectroniqueInc.1010,7thAvenue,Grand‐Mère(Quebec)G9T2B8,CanadaTel:1‐819‐533‐3553Fax:1‐819‐533‐3577www.synapseelectronique.com
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.17/19ANNEXES
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.18/191 INTEGRATIONCONSIDERATIONSFORTHESTE402NP+THERMOSTAT1.1 MechanicconsiderationsThedesignandverificationsontheSTE402NP+thermostatwereperformedinaccordancewiththefollowingspecifications.Doingotherwisethanindicatedinthissectioncouldnegativelyimpacttheradioperformance.MechanicintegrationintheSTE402NP+inmm1.2 PCBintegrationconsiderationsDevelopmentandtestsweredonewiththelayoutandthegroundplaneillustratedhereunder.Doingotherwisethanindicatedinthissectioncouldnegativelyimpacttheradioperformance.ModuleintegrationontheSTE402NP+PCBinmm
SYN‐RF‐ZW01UxZ‐WAVERADIOMODULETECHNICALSPECIFICATIONRev. 3 – September 015    CONFIDENTIALITY: The information in this document is strictly confidential and is the sole property of Synapse Électronique Inc. This information may not be reproduced, used or transmitted in any form, in part or in whole, without the written consent of Synapse Électronique Inc.19/192 INTEGRATIONCONSIDERATIONSINTHESTE‐CIR034HEATINGCONVECTOR2.1 MechanicconsiderationsThedesignandverificationsweredoneaccordingtothefollowingspecifications.Doingotherwisethanindicatedinthissectioncouldnegativelyimpacttheradioperformance.MechanicintegrationintheCIR034(convector)inmm2.2 PCBintegrationconsiderationsDevelopmentandtestsweredonewiththelayoutandthegroundplaneillustratedhereunder.Doingotherwisethanindicatedinthissectioncouldhaveanimpactontheradioperformance.ModuleintegrationintheCIR‐034heatingconvectorinmm

Navigation menu