TAIDOC TECHNOLOGY 9030A01 TD-9030A User Manual Attachment 3
TAIDOC TECHNOLOGY CORP. TD-9030A Attachment 3
User Manual
User Manual TD-9030A Brand Name: TaiDoc FCC ID: TM79030A01 Version 1.0 2014-07 A1.0 - 1 of 7 Description: The TD-9030A is a low power and low costs Bluetooth 4.0 BLE module based on the 32 bit ARMR Cortex™-M0 CPU .Perfect for communication and cable replacement between your device and a smartphone, computer or other devices. It is easy to setup and use thanks to real and virtual UART interface and AT commands. Key Features 2.4 GHz transceiver -93 dBm sensitivity in Bluetooth® low energy mode 250 kbps, 1 Mbps, 2 Mbps supported data rates TX Power -20 to +4 dBm in 4 dB steps TX Power -30 dBm Whisper mode 13 mA peak RX, 10.5 mA peak TX (0 dBm) RSSI (1 dB resolution) ARM® Cortex™-M0 32 bit processor 275 μA/MHz running from flash memory 150 μA/MHz running from RAM Memory 256 kB or128 kB embedded flash program memory 16 kB RAM UART (CTS/RTS) Applications Medical devices BGM BPM A1.0 - 2 of 7 1. Pinout and Terminal Description Figure 1: Pinout Pin Symbol I/O Type Description BAT_Monitor Battery Voltage Monitor VBAT Power input VBAT Power input VCC Power Output VCC Power Output VCC Power Output NC NC Not Connect DEV_STAT Wakeup Device PIO-0 I/O GPIO 10 PIO-1 I/O GPIO 11 DTM_RTS UART RTS signal (Note.1) 12 DTM_CTS UART CTS signal (Note.1) 13 DTM_TX UART TX signal (Note.1) 14 DTM_RX UART RX signal (Note. 1) 15 GND GND A2.1 - 3 of 7 16 GND GND 17 SWDCLK JTACK Clock 18 SWDIO I/O JTACK Data 19 DTM_Mode Set Low to DTM Mode Set High to BLE Mode 20 NC NC Not Connect 21 BLE_RX UART RX 22 BLE_TX UART TX 23 BLE_CTS UART CTS 24 BLE_RTS UART RTS 25 NC NC Not Connect 26 Paring_Key Set Low to Paring Device 27 NC NC Not Connect 28 LED LED indicator 29 GND GND 30 NC NC Note.1 DTM is Direct Test Mode。 Not Connect 2. Power supply The Module accept 3.1V to 4.2V DC voltage input,Power supply should guarantee good ripple suppression and enough current. 3. Antenna The module integrates a chip antenna so there’s no need to use antenna on customer’s PCB. 4. UART interface This is a standard UART interface for communicating with other serial devices. The UART interface provides a simple mechanism for communicating with other serial devices using the RS232 protocol. The UART CTS and RTS signals can be used to implement RS232 hardware flow control where both are active low indicators. Default parameter set is 19200,8,n,1 A2.1 - 4 of 7 5. Dimension A2.1 - 5 of 7 FEDERAL COMMUNICATIONS COMMISION (FCC) STATEMENT 15.21 You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment. 15.105(b) Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference and 2) This device must accept any interference received, including interference that may cause undesired operation of the device. FCC RF Radiation Exposure Statement: 1. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. A2.1 - 6 of 7 根據 NCC 低功率電波輻射性電機管理辦法 規定: 經型式認證合格之低功率射頻電機,非經許可,公司、商號或 第十二條 使用者均不得擅自變更頻率、加大功率或變更原設計之特性及 功能。 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經 發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續 第十四條 使用。前項合法通信,指依電信法規定作業之無線電通信。 低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻 射性電機設備之干擾。 A2.1 - 7 of 7
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : kolinda Create Date : 2014:07:17 18:04:56+08:00 Modify Date : 2014:07:17 18:04:59+08:00 Subject : Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2014:07:17 18:04:59+08:00 Creator Tool : Acrobat PDFMaker 9.1 Word 版 Document ID : uuid:2c73aa51-89c6-4f54-907c-3bcdd0505a4e Instance ID : uuid:4489da2a-944e-463a-a027-924aa8ff60e3 Format : application/pdf Title : Attachment 3 Description : Creator : kolinda Producer : Adobe PDF Library 9.0 Keywords : Source Modified : D:20140711085818 Company : Page Layout : OneColumn Page Count : 7EXIF Metadata provided by EXIF.tools