TCITY ELECTRONICS TC88 TPMS User Manual
SHENZHEN TCITY ELECTRONICS CO.,LTD TPMS Users Manual
User Manual
Instruction Manual Tire Pressure Monitoring System Monitor Specification Monitor Feature Sensor Specification sensor sensor ·Automatically solar power battery recharger. ·pressure and temperature alarm. ·Visible and audible alarm. ·Selectable pressure unit(PSI,BAR). ·Selectable pressure unit(℃,℉). ·Configurable high/low pressure and high temperature alarm. ·Tire position exchange. ·Automatic awake feature. ·Automatic backlighting. ·Built in rechargeable lithium battery. ·Monitor up to 7 tires(including one spare tire). ·Display temperature and pressure simultaneously. ·Fast leakage alert. ·High stability and easy to install. Remark:The photo only for referance,configure according to the type that you selected Function button using according to the actual machine 12 01 1.Please use system correctly in the right condition. The distributor is not liable fordamages form the miss-use. 2.Installation should follow the instruction guide,if any damage occurs due to thewrong installation,the distributor is not liable for it.The content and specification are subject tochange without prior notice.Pictures in the article are just for illustration. 3.Please take the actual product for reference.Internal sensor installation should be carried out by professional person. Be wareof the internal sensorswhile reload the tire. 4.Please be careful not to damage the sensor during the removal 13 Inflate Code Learnings in standby mode, press and hold “+”button andreleaseit after the beep sound toenter learning mode ,the tire iconwill flash on the LCD with “Id”Letter showing the beginning letter of the tire T6、T8、T9 Display ID code. Short press “-”or “+”to scroll tire position needed to re-code.Once ready, then mount the sensor on to the tire valve (for externalsensor),or inflate the tire(for internal sensor),once the sensor sensed the inflator,the sensorwill send its own ID code to the monitor and the monitor willdisplay itʼssensor code after the beep. Repeat above step to re-code others sensor if T5 Display Pressure unit Solar charging icon The tire temperature Temperature of numerical display the unit The tire pressure The alarm icon numerical display needed.Press“ Spare tire icon Power display ”or “ ”until Beep sound to ensure new code completed stored intothe monitor.if press “ +” “ standby mode. Sensor low electric icon Installation Tips Monitor should be installed in appropriate place using the sticky padorthe magic tape. Recharge the monitor by theDC-DC power adaptor forfirst time and allow continue recharge by solar power after the firstfull DC recharge 02 ” or “+” “ buttons together will not store any new ID and resumeto 11 ” Use fixture provided inside package and open the plastic enclosure in counter clockwise direction Parameters Settings In standby mode,press the “ 1st beep to enter the ” or “ ” button,releaseafter the 1st set up menu. The corresponding icon on the LCD will flash. Press the “ ” or “ ” button to select the desired setting, press button “+”or “-” to select the data. After the setting is finished , press the “ Remove battery from battery holder ” or “ ” button to save the setting and exit after a beep. Press the button “+” and “ ” or “+” and “ ” at the same time to exit without saving the setting. The monitor will return to stand by mode if there is no operation within 1 min in the setting mode. Replace new lithium battery ,ensure positive“+”is facing upwards Setting Sequence 1.Pressure Unit While the PSI or BAR iconis flashing ,press the button “+”or“-”to select the desired unit. Remount plastic enclosure using the fixture provided in counter clockwise direction Rubber o-ring 10 03 sensor installation Tips:piease ensure to turn on the monitor firsely before install the sensor so that the monitor can receive the sensor data on time. 5.High Temperayure Setting While the high temperature data and all tire icons Are flashing ,press the button “+”or“-”to set the Desired temperature data . Hex nut Mount the hex nuts To restore the factory default setting: Air Valve Screw in sensor at clock wise direction First turn off the monitor by pressing“ ” ,then turn on the monitor again until all icons displayed and press the button“ ”or “ “within 3 seconds,release after a“ Bi ”sound will light to complete factory reset. Tire position exchange Sensor Tidhten hex nuts in counter clock wise Direction Hex nut 08 During standby mode, long press “-”until “BI” sound to begin, one tire will flash and use “ + ”or “ - ” to exchange to a new tire position and confirm by pressing “ ” or “ ” button Repeat using “-” to choose another tire and follow by using“+”or “-” button to exchange another new tire and finished by pressing “ ” or “ ” buttonagain with a long beep.(During ID interchange mode if no action for one minte, systemwill resume to normal mode operation) 05 2.Temperature Unit While the ℃ or ℉ icon isflashing ,press the button “+”or “-” to select thedesired unit. internal sensor installation (1)Unload the from the vehicle and deflate the tire. (2)Use tire changers to demount the tire and remove the original valve. 3.High Pressure Setting for Front Tires While the two front tire icons and the high pressuredata icons are flashing ,press the button“+”or“ - ”to select the desired pressure data. (3)Take out the Ring ,Nut ,Vale Cover of the sensor. 4.Low Pressure Setting for Front Tires (4)Use the specified spanner to loose the sensor’s valve firstly, put the sensor to the wheel hub and using hand to adjust the best installation position and tighten the sensor valve, and then take out the sensor and using the specified spanner to tighten the sensor again. While the two fornt tire icons and the low pressure data icons are flashing ,press the button “+”or“-” to select the desired pressure data . 04 5.High Temperayure Setting While the high temperature data and all tire icons Are flashing ,press the button “+”or“-”to set the Desired temperature data . 09 Fast Leakage Alert The sensor will send alert data to the monitor if it detects fast leakage in a tire. The alert icon and the pressure data will flash together with the tire icon. Sensor Low Batter Alert To restore the factory default setting: First turn off the monitor by pressing“ ” ,then turn on the monitor again until all icons displayed and press the button“ ”or “ “within 3 seconds,release after a“ Bi ”sound will light to complete factory reset. While the sensor battery voltage is low, the sensor will send the alert to themonitor . The corresponding tire icon and the low battery icon Tire position exchange During standby mode, long press “-”until “BI” sound to begin, one tire will flash and use “ + ”or “ - ” to exchange to a new tire position and confirm by pressing “ ” or “ ” button Repeat using “-” to choose another tire and follow by using“+”or “-” button to exchange another new tire and finished by pressing “ ” or “ ” buttonagain with a long beep.(During ID interchange mode if no action for one minte, systemwill resume to normal mode operation) 06 Factory default alarm setting 07 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. To assure continued compliance, any changes or modifications not expressly approved by the party. Responsible for compliance could void the user’s authority to operate this equipment. (Example- use only shielded interface cables when connecting to computer or peripheral devices). This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Administrator Create Date : 2017:04:26 16:39:19+08:00 Modify Date : 2017:06:08 18:40:42+08:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : Administrator Title : 英文内外置排版.cdr Creator Tool : CorelDRAW X7 Metadata Date : 2017:06:08 18:40:42+08:00 Producer : Corel PDF Engine Version 17.0.0.491 Document ID : uuid:2e3dab21-1587-4f40-895a-dae41267b4cc Instance ID : uuid:1e478fab-ef0c-4a85-a85c-eda1b8be8dd3 Page Count : 5 Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract)EXIF Metadata provided by EXIF.tools