TECHCity Technology PS-30X iPower User Manual
TECHCity Technology Co., Ltd. iPower
User Manual
e2-Live Home Automation iPower Smart Power Socket PS-30X Instruction Manual Edit by Shine Lo e2-Live Home Automation iPower Specifications Hardware e2-Live RF Tx/Rx 2 way module Frequency:433.92MHz +/- 150KHz Digital ID coding (0000~9999) Received / Emit distances : open space 60 meters Specifications of loading Power overload protection of recovery fuse x1 3 circuits ON/OFF totally loading 110V 1650W 220V 1800W RS-485 communication,0.1A power fuse Functions 3 circuits sockets Manual tock switch ON/OFF Remote ON/OFF Power detection, checkup the actual power states (with scenario usage of RP-20) With RS-485 two way communication (control or inquiry) Accept e2-Live ALL OFF commands, can be set to enable or disable Edit by Shine Lo e2-Live Home Automation Hardware All circuits can manual ON/OFF switch, with HA power detection of RP-20, please keep the status power on with blue LED extinguish) Appearances Used for two way control or inquiry communic ation via RS-485 Overload recovery fuse protection, it will shut down automatically to protect iPower itself, and will return to normal situation when overload was removed Edit by Shine Lo 3 circuits total loading are 110V 1650W 220V 1800W While overload happened, iPower will shut down the main power automatically, recover when overload was removed e2-Live Home Automation Accessary Power line Note: Special specifications, please with this power line for ipower using in order to make sure correct operations. Edit by Shine Lo e2-Live Home Automation Setting iPower Set up before using : ID & position of remote button Main function is to be controlled wirelessly by all kind of remote controller of e2-Live. General functions : For connected device, which does not need to know the status of power, or judge the function. Tools required: RC -07 scenario remote control, the first zone to third zone RC -09 intelligent remote control, the first zone HT -100 LCD remote control, the first zone to fifth (except zone 1 to 7 ) Itouch lighting / curtain / power supply area (except power zone 1 to 7) RP -20 software, the first zone to fifth (except fifth zone no. 1 to 7) iPower can be set at any position for remote control Actions before setting:: 1. Firstly set up the remote ID, for example: RC -07 / RC 07 / RC-09 must be set up a four-digit ID; itouch or RP -20 software is need to define the four-digit ID through software. 2. Determine iPower's 1 ~ 3 circuits to corresponding position. 3. Determine the connected device accept remote control “All off”. Setting Description: 1.Press and hold the position of wanted circuit, such as the first one. 2.Take a paper clip to poke tact switch in the hole, until the red LED constant light up. 3. Pick up the setting of the Remote Control, press the wanted number, then press “ON” to not accept the "All off" control, press “OFF” to accept the "All off" control. 4. Red LED starts flash (up to 7 times) indicates the setup is successful. 6. After entering the setting mode, there are 15 seconds to setting, if red LED has extinguish that means setting unsuccessfully. Edit by Shine Lo e2-Live Home Automation Using the RC-07 remote control to set the first circuit of iPower Second District, No. 5 position, to accept the "All off" control set 1. Press the button and hold iPower first circuit (1) 2. Setting stick or paper clip poke the tact switch in (2) Setting stick or paper clip poke the tact switch in (2) (2) Red LED light on (1) Press and hold (3) 3. Press RC-07 (3) 4. Press RC-07 (4) (5),to accept “All off” control 5. Press RC-07 Red LED flashing means successful。 (4) (5) Remote function confirmed: Press RC-07 ,press ,press ,blue LED extinguish Press RC-07 ,press ,press ,iPower blue LED light on Press and hold RC-07 ,then press and release both to perform “All off" function,iPower first circuit blue LED light on. Edit by Shine Lo e2-Live Home Automation Link connect RP-20, when scenario is been executed, it will detect the power status of your appliances For appliances, used with RP-20 in scenario control, detect the real ON or OFF situation to ensure the accuracy of scenario performance.. Specifies the appliance's remote position setting for number 1 ~ 7 of fifth zone. Require tool:HT-100 itouch RP-20 LCD remote control, fifth zone position 1 to 7 Power zone position 1 to 7 fifth zone position 1 to 7 (The most convenient setting tool) Preparatory actions before setting: 1. Be sure you are well defined the tool ID you wanted 2. Be sure your location is linked to the right appliance. please refer to the corresponding preset value for convenient checking AMP Power → zone 5 No. 1 TV Power →zone 5 No. 2 STB Power →zone 5 No. 3 DVD Power →zone 5 No. 4 CD Power →zone 5 No. 5 CATV Power →zone 5 No. 6 AUX Power Edit by Shine Lo →zone 5 No. 7 e2-Live Home Automation 3. Plug in the device corresponding position, adjust to detect the right current consumption when power on and off. Appliances and iPower control location setting is complete and correct detection from the current adjustment, to make sure correct linking function be executed from RP-20.. Specifies light fifth zone 1-7 for power detection position. For example: 1. Connect to PC with RP-20 via USB, open RP-20 software, checking COM connection. 2. RP-20 software provides two places available to transfer ID code (1) Home page: power control coding. The mode is not accept “All off”. Illustrated as follows (2) Control Validation:in ” light & curtain” select accept “All off” or not accept “All off”. 3. In setting mode (1) Press and hold (2) poke the tact switch in setting hole, red LED light on Setting stick or paper clip poke the tact switch in (2) (2) Red LED light on (1) Press and hold 4. Using RP-20 home page to transfer code, as shown below (一) Using Control Validation/ Light & Curtain to transfer code,as shown below(二),step3~5 5. iPower received , red LED quick flashing means setting successfully. Edit by Shine Lo e2-Live Home Automation Control Validation/ Light & Curtain Plug in the above appliance and power on, blue LED extinguish (圖一) (3) (4) (5) Accept all lights off function Not accept all lights off function (圖一) AMP Power → Zone 5 No.1 light TV Power → Zone 5 No. 2 light Edit by Shine Lo e2-Live Home Automation STB Power → Zone 5 No.3 DVD Power → Zone 5 No.4 CD Power → Zone 5 No.5 CATV Power → Zone 5 No.6 AUX Power → Zone 5 No.7 iPower power status detection & RP-20 scenario editing setting In scenario edit setting graphic, for TV/CD/DVD/AMP/STB/CATV/A/C, all of these 7 appliances can select power current detectionfunction. Always ON : in scenario function been executed, RP-20 will checking the power current status. If TV is power ON, RP-20 will not send out action. command Always OFF : If TV is power OFF, RP-20 will not send out reverse action. No Detect : Don’t care about the status of the power, not action. Edit by Shine Lo to avoid the reverse command to avoid the 10 e2-Live Home Automation Power current detection setting : Step 1 Plug in appliance in iPower socket, Press button to provide power to this device (blue LED light off) Step 2 Turn on the device power (in operation mode, not in standby mode) Red LED light on : the device is power off Red LED light off : the device is power on Step 3 Use flat head screw driver to adjust red LED light on. Then turn the knob back let LED just light off. Step 4 Manual or remote to turn off the device power Red LED light on Then turn on the device to see red LED light off . The setting is done Plug the corresponding appliance in iPower socket, adjust the current knob of appliances one by one. 1.) When the socket connector, without Transformer / stabilizer of equipment → Adjust the knob to the small load direction limition. ※ Such equipment almost no power consumption in standby mode, when the equipment is power on (Relay ON) iPower can detect its current power (if the current power > 5w) 2.) When the socket connector, with Transformer / stabilizer of equipment a.) Plug in the equipment, turn on iPower and the equipment. b.) Use flat head screw driver to adjust red LED light on. Then turn the knob back let LED just light off., this was the correct position the power on current consumption can be detected c.) Verification: i) Turn off the appliance (load no electricity); LED indicator → [Bright] . ii) Open the appliance (loaded with electricity); LED indicator → [OFF] ※ transformer / ballast itself in the standby mode already has power, if not through the current limitation adjustment, iPower can not properly judge the current electrical load is in working electricity mode or in Standby mode. Edit by Shine Lo 11 FCC WARNING This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2015:08:26 14:32:29+08:00 Create Date : 2015:08:06 18:21:33+08:00 Metadata Date : 2015:08:26 14:32:29+08:00 Format : application/pdf Title : Microsoft Word - A1_PS-301_iPower_smart power socket_20150805_eng.doc Creator : Patrick Document ID : uuid:3a07ba8c-5955-45f9-b169-69bdbf787100 Instance ID : uuid:f253f56e-b3da-4bf0-b9f0-77c2bc581e0d Page Count : 12 Author : PatrickEXIF Metadata provided by EXIF.tools