TEKTELIC Communications orporated T0004279 Gateway interface between LoRa nodes and network server User Manual 2150 RRH SDS

TEKTELIC Communications Incorporated Gateway interface between LoRa nodes and network server 2150 RRH SDS

User Manual

Download: TEKTELIC Communications orporated T0004279 Gateway interface between LoRa nodes and network server User Manual 2150 RRH SDS
Mirror Download [FCC.gov]TEKTELIC Communications orporated T0004279 Gateway interface between LoRa nodes and network server User Manual 2150 RRH SDS
Document ID3339393
Application IDjDjEq4nCI/coJ/IkctyAvA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize51.5kB (643706 bits)
Date Submitted2017-03-30 00:00:00
Date Available2017-03-30 00:00:00
Creation Date2017-03-24 16:06:17
Producing SoftwareAdobe PDF Library 10.0
Document Lastmod2017-03-24 18:18:40
Document Title2150_RRH_SDS
Document CreatorAcrobat PDFMaker 10.1 for Word
Document Author: Tom Danshin

TEKTELIC COMMUNICATIONS INC.
Document type:
User Guide
Document number:
T0004279_UG
Document version:
2.8
Document Status:
Approved
Product name:
Kona Macro Gateway
Product codes:
T0004142, T0004470, T0004250, T0004251,
T0004252, T0004537
TEKTELIC Communications Inc.
th
7657 10 Street NE
Calgary, AB, Canada T2E 8X2
Phone: (403) 338-6900
© 2016 TEKTELIC Communications Inc., All rights reserved.
All products, names and services are trademarks and registered trademarks of their respective companies.
Disclaimer:
Material contained in this document is subject to change without notice. The material herein is solely for
information purposes and does not represent a commitment by TEKTELIC or its representatives. TEKTELIC has
prepared the information contained in this document solely for use by its employees, agents, and customers.
Dissemination of this information and/or concepts to other parties is prohibited without the prior written consent
of TEKTELIC. In no event will TEKTELIC be liable for any incidental or consequential damage in connection with the
furnishing, performance or use of this material.
TEKTELIC reserves the right to revise this publication in accordance with formal change control procedures defined
by TEKTELIC.
Revision History
Version
Date
Status
Editor
Comments
1.0
Oct 5, 2016
Draft
T. Danshin
2.0
Nov 1, 2016
Draft
P. Chu
2.1
Nov 8, 2016
Draft
P.Chu
2.2
Dec 9, 2012
Draft
P. Chu
2.3
2.4
2.5
2.6
2.7
2.8
Jan. 23, 2017
Feb. 09, 2017
Mar. 07, 2017
Mar. 08, 2017
Mar. 08, 2017
Mar. 24, 2017
Draft
Obsolete
Obsolete
Obsolete
Approved
Approved
S. Morrison
S. Morrison
S. Morrison
S. Morrison
S. Morrison
T. Danshin
First release
Updated for 1TX-1RX Module Type, v2.1 Semtech
SW
Updated environmental and DC voltage specs
Updated Commissioning Section to use GUI for
Gateway operation
Renamed to User Guide, numerous updates
Updates to connector & mounting information
Changed ground lug to imperial
Added 10A maximum DC input rating
Added language translation & LoRa antenna type
Added MPE information
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 2 of 34
Table of Contents
Product Description ................................................................................................................. 5
1.1
Overview .......................................................................................................................... 5
1.2
Connectors ....................................................................................................................... 7
1.3
Specifications.................................................................................................................. 10
Installation ............................................................................................................................. 11
2.1
Safety Precautions.......................................................................................................... 11
2.2
Unpacking and Inspection .............................................................................................. 12
2.3
Required Equipment for Installation .............................................................................. 12
2.4
Kona Macro Gateway Mounting .................................................................................... 12
2.5
Ground Cable Installation .............................................................................................. 14
2.6
Direct DC Power Cable Installation ................................................................................ 15
2.7
RF Cable Installation ....................................................................................................... 16
2.8
Copper Ethernet Cable Installation ................................................................................ 16
Commissioning and Monitoring ............................................................................................ 17
3.1
Required Equipment ...................................................................................................... 17
3.2
Procedure ....................................................................................................................... 17
Radio Compliance Statements .............................................................................................. 18
Description du produit........................................................................................................... 20
5.1
Vue d'ensemble .............................................................................................................. 20
5.2
Connecteurs ................................................................................................................... 22
5.3
Caractéristiques.............................................................................................................. 25
Installation ............................................................................................................................. 26
6.1
Précautions de sécurité .................................................................................................. 26
6.2
Déballage et inspection .................................................................................................. 27
6.3
Matériel requis pour l'installation.................................................................................. 27
6.4
Montage Kona Macro Gateway ..................................................................................... 28
6.5
Installation du câble de masse ....................................................................................... 29
6.6
Installation du câble d'alimentation CC direct ............................................................... 30
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 3 of 34
7
6.7
Installation du câble RF .................................................................................................. 31
6.8
Installation du câble Ethernet en cuivre ........................................................................ 31
Mise en service et surveillance.............................................................................................. 33
7.1
Équipement requis ......................................................................................................... 33
7.2
Procédure ....................................................................................................................... 33
Déclarations de conformité à la radio ................................................................................... 34
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 4 of 34
1 Product Description
1.1
Overview
The Kona Macro Gateway is a LoRaWAN IoT gateway that supports the full range of US902-928
channels. The Kona platform is designed to support a multitude of deployment configurations
in an outdoor environment. The hardware architecture supports one or two LoRa antennas, a
GPS antenna, direct DC input power or Power over Ethernet (PoE), and backhaul options
including copper Ethernet, optical Ethernet, and 3G/4G wireless. Table 1 presents the currently
available Kona Macro Gateway models.
Table 1: Kona Macro Gateway Models
Model
Product
Code
T0004142
T0004470
T0004250
T0004251
T0004252
T0004537
Description
KONA MACRO
KONA MACRO, DC
POWER, 3G/4G
KONA MACRO, DC
POWER, 2X LORA,
3G/4G
KONA MACRO,
OPTICAL & DC
POWER
KONA MACRO,
OPTICAL & DC
POWER, 2X LORA
KONA MACRO, DC
POWER, 2X LORA
GPS
Ant.
Direct
DC
Power
Optical
Copper
Eth.
3G/4G
Ant.
LoRa
Ant.
Figure 1 illustrates the common Gateway external form-factor; the differences between the
various models are limited to the connector bulkhead layout. Figure 2 illustrates the bulkhead
layouts for the Kona Gateway models.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 5 of 34
Figure 1: Kona Macro Gateway Common Dimensions
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 6 of 34
Figure 2: Kona Macro Gateway Bulkhead Layouts
1.2
Connectors
The Kona Gateway connector field is detailed in Figure 3 for the T0004250 model. Not all
connectors are present on other models. The DC power connector is replaced by a hybrid DC
power/Fiber connector on models which support fiber backhaul capability as with the
T0004252 model detailed in Figure 4.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 7 of 34
GPS
Antenna
DC Power
2 pin CPC
LoRa RF
Antenna 1
LED
Protective
Earth
Ground
LoRa RF
Antenna 0
Copper
Ethernet
Enclosure
Vent
3G/4G
Modem
Antenna
Figure 3: Kona Macro Gateway T0004250 Connector Field
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 8 of 34
GPS
Antenna
DC Power /
Fiber Hybrid
LoRa RF
Antenna 1
LED
Protective
Earth
Ground
LoRa RF
Antenna 0
Enclosure
Vent
Copper
Ethernet
Figure 4: Kona Macro Gateway T0004252 Connector Field
All Kona Gateway module interconnect is located on the bottom facing bulkhead. The RF
connectors are water proof while un-mated but all other connectors must be terminated with
mating connectors or covered with the supplied protective cap when not in use in order to be
water tight. Connector types and their mating connectors are listed in Table 2.
Table 2: Kona Macro Gateway Interface Connector Types
Interface
QTY
Connector Type
Mating Connector
LoRa Antenna Ports
1 or 2
N-Type female
Industry standard N-Type male
3G/4G Modem
Backhaul Antenna Port
0 or 1
N-Type female
Industry standard N-Type male
Threaded, circular, RJ-45
Shenzhen Chogori Technology Co., Ltd.
approved mating connector (p/n
33000111-02 or equivalent)
Threaded, circular, 2
Shenzhen Chogori Technology Co., Ltd.
Copper Ethernet Port
Direct DC Power Input
0 or 1
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 9 of 34
Port
Hybrid Direct DC
Power/Fiber Ethernet
Port
0 or 1
contact DC power
approved mating connector (p/n
23002211-02, or equivalent)
Harting Hybrid DC Power
/ Optical connector
Harting Technology Group approved
mating connector
GPS Port
N-Type female
Industry standard N-Type male
Earth Ground
Chassis Protective Earth
Ground terminal
Industry standard 2-hole lug, 1/4 x 0.75”
spacing
1.3
Specifications
The Kona Macro Gateway specifications are listed in Table 3.
Table 3: Kona Macro Gateway Specifications
Attribute
Specification
Dimensions
222.2mm (8.7”) wide x 101mm (4.0”) deep x 287.3mm (11.3”) tall
Weight
5.1 kg (11.3 lbs)
Operating Temperature
-40°C to 60°C (-40°F to 140°F) at sea level Including solar loading.
Relative Humidity
10% to 100%
Operating Altitude
-60 m to 4,000 m (-197 ft to 13,123 ft)
Power Input, Direct DC
48 VDC nominal, 37 to 57 VDC operating range after 42 V maximum start-up
threshold. Positive or negative ground referenced feed. SELV source
required. Maximum 10A input overcurrent protection.
802.3 at Type 2 Class 4, Mode A or Mode B standard but constrained to 3m
maximum cable length and 56V minimum PSE output voltage.
Power Input, PoE
Power Consumption
Weather Tightness
Regulatory Compliance
Surge Protection
Four pair powering is supported and preferred, and is required to otherwise
meet the full 802.3 at Type 2 Class 4 operating specifications for cable
length.
35 W maximum, 1.0 A maximum with direct DC powering
34 W maximum, 0.6 A maximum with PoE
UL Type 6 (IP-67)
CSA/UL 60950-1 & CSA/UL 60950-22
FCC Pt. 15 Class B
All interfaces are protected to primary levels except for the 3G/4G modem
antenna port which supports local antenna mounting only or requires
external surge suppressor.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 10 of 34
2 Installation
2.1
Safety Precautions
•
Installation, operation, and maintenance of the Kona Macro Gateway must only be
performed by a professionally trained service technician who is aware of all hazards
involved.
•
The Kona Macro Gateway must be installed in a restricted access location (such that
touching of the Gateway by non-service persons is not likely).
•
The Kona Macro Gateway may become hot to the touch during normal operation at
elevated ambient temperatures. The surface temperature of the Gateway may reach 90°C.
•
The Kona Macro Gateway has no internal field serviceable parts. The Gateway module must
only be opened by an approved TEKTELIC service center.
•
All installation practices must be in accordance with the local and national electrical codes.
•
Do not work on the system during periods of lightning activity.
•
The Kona Macro Gateway is considered permanently connected equipment. The Protective
Earth Ground connection (that is, the two-hole lug to chassis ground) is always required.
•
Ensure the Kona Macro Gateway Protective Earth Ground connection is properly terminated
prior to the connection of any other interfaces.
•
The Kona Macro Gateway contains primary lightning surge suppression on the Direct DC
power port, the Copper Ethernet port, the GPS antenna port and the LoRa RF antenna
ports. The primary lightning protectors have the ability to bridge the interface isolation
boundary during over-voltages. Ensure that the Protective Earth Ground connection is
always in place.
•
Ensure that the Kona Macro Gateway, its antennas and supporting structures are properly
secured to eliminate any physical hazard to people or property. The Gateway must be
securely mounted according to the mounting instructions prior to any cable connection and
operation.
•
The Kona Macro Gateway does not contain a power supply disconnection device; a readily
accessible disconnection device must be incorporated external to the Kona Macro Gateway.
•
The direct DC powered Kona Macro Gateway shall be supplied through an input overcurrent
protection device rated not more than 10 A. The overcurrent protection must have the
appropriate current interrupt capacity for the power source and must be incorporated into
the non-earthed conductor(s) of the Kona Macro Gateway DC supply.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 11 of 34
•
For the direct DC power feed option, the DC positive pin must be at positive potential
relative to the DC negative pin. If the polarity is reversed, the unit will not sustain damage
but will not operate until the connection polarity is corrected.
•
Although the Kona Macro Gateway can be powered through either a direct DC input or
through power over Ethernet (PoE), simultaneous application of power to both inputs may
result in unexpected operation and shall be avoided.
•
The Kona Macro Gateway power source must meet SELV requirements.
2.2
Unpacking and Inspection
The following should be considered during the unpacking of a new Kona Macro Gateway.
1. Inspect the shipping carton and report any significant damage to TEKTELIC.
2. Unpacking should be conducted in a clean and dry location when possible.
3. Do not discard the shipping box or foam inserts as they will be required if a unit is
returned for repair or re-configuration.
2.3
Required Equipment for Installation
The following tools are required to install the Kona Macro Gateway module:
1. A 6 point metric socket set and torque wrench drive.
2. Anti-oxidant compound (NO-OX-ID, Penetrox, Noalox, Ox-Gard or equivalent).
3. A small wire brush.
4. A clean cloth.
5. Weatherproofing tape kit for the RF connectors (Scotch Wireless Weatherproofing Kit,
WK-101 recommended).
6. Appropriately sized pipe clamps for pole mounting or appropriate screws or bolts (four
sized M8) with any required anchors according to the wall construction for wall
mounting.
2.4
Kona Macro Gateway Mounting
Kona Macro Gateway is designed to be mounted to a vertical pole or wall using a mounting
bracket. The mounting bracket is a single part that bolts to the back surface of the Gateway
using supplied hardware (four M6x1.0 - 14 mm bolts with flat and star lock washers) as
illustrated in Figure 5. The Gateway module must be oriented with the connector bulkhead
facing down, towards earth.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 12 of 34
Ensure that the structure to which the Gateway is being mounted is secure and able to support
a dead load of at least 136 kg (300 lbs). The area below must be free of any obstructions to
cable ingress.
Figure 5: Kona Module with Mounting Bracket
The Kona Macro Gateway wall mounting procedure is as follows:
1. Bolt the wall mounting bracket to the Gateway module using the supplied bolts and
washers.
2. Install 2 site supplied M8 bolts into the wall at 139.7 mm (5.5”) center spacing, leaving
the bold heads protruding with a 2mm gap from the wall surface.
3. Hang the Kona Macro Gateway with bracket from the two bolts by inserting the keyhole
slots at the top of the bracket onto the 2 bolts and tightening the bolts.
4. Insert and tighten two additional site supplied M8 bolts through the holes at the bottom
of the bracket.
The Kona Macro Gateway pole mounting procedure is as follows:
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 13 of 34
1. Bolt the wall mounting bracket to the Gateway module using the supplied bolts and
washers.
2. While temporarily supporting the Gateway with bracket, install the two site supplied
pipe clamps, one through each of the upper and lower slotted clamp mounting points.
2.5 Ground Cable Installation
The Kona Macro Gateway is considered Permanently Connected Equipment and requires a
permanently connected Protective Earth Ground (PEG) conductor. The Protective Earth Ground
connection is made through a 1/4 x 0.75” on center double hole lug to the ground termination
point illustrated in Figure 6. The ground cable gauge shall be #10 AWG minimum.
The Kona Macro Gateway grounding system shall follow local and national electrical codes. The
Protective Earth Ground conductor terminated at the double hole lug point is mandatory and
must be the first connection made to the Kona Macro Gateway during installation. Proper
routing and termination of this cable is key to robust lightning withstand performance; in high
susceptibility installations, every effort shall be made to minimize connection inductance and
ground bed resistance.
The ground cable installation steps are as follows:
1. Lightly abrade the surface of the casting ground area with a fine wire brush to remove
the oxide layer.
2. Use a clean cloth to remove any debris from this surface.
3. Immediately coat the contact surface with a thin layer of anti-oxidant compound.
4. Install the ground cable through its 2-hole lug onto the chassis ground point using the
two supplied 1/4 - 20 x 1/2” bolts with flat and star lock washers, torqued to 10.4 Nm
(92 in·lbs).
Figure 6: Chassis Ground Connection
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 14 of 34
2.6
Direct DC Power Cable Installation
Depending on the model, the Kona Macro Gateway direct DC feed may terminate at a
dedicated two pin circular plastic connector (CPC) or at a hybrid three pin DC with optical
connector. The direct DC power input is isolated from chassis (earth) with the exception of the
primary surge suppressors. One lead of the DC power feed is normally earth referenced
external to the Kona Macro Gateway (usually at the power source by convention).
The DC power cable shall be rated for outdoor application according to local and national
electrical codes.
The CPC direct DC connector shall be as specified in Table 2 and shall follow the signal polarity
identified in Figure 7.
Black
DC Negative
Keyed DC Power
Connector (CPC)
White
DC Positive
DC Positive
DC Negative
Figure 7: Direct DC Power CPC Connector Connection Polarity
The hybrid direct DC power connector shall be as specified in Table 2 and shall follow the signal
polarity identified in Figure 8. Although this connector supports a third wire for a ground
connection, this ground is supplementary and does not replace the principle ground wire
terminated at the two-hole lug chassis ground point.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 15 of 34
Green
Ground
DC Positive
Black
DC Negative
Ground
DC Negative
White
DC Positive
Keyed DC Power Connector (Hybrid)
Figure 8: Hybrid Connector Direct DC Power Connection Polarity
2.7
RF Cable Installation
The Gateway installation will require connection to a GPS antenna, one or two LoRa RF
antennas, and optionally a 3G/4G modem antenna. The RF cables attach to the N-Type
connectors on the bottom of the Kona Macro Gateway. Torque the connectors to 1.7 to 2.3 Nm
(15 to 20 in·lbs). The N-Type connector interface to a cable is not water proof and must be
taped to be used outdoors. TEKTELIC recommends taping with Scotch Wireless
Weatherproofing Kit, WK-101. Follow the taping procedures outlined by the supplier of this
tape system.
Note that the 3G/4G modem antenna port is not surge protected and, accordingly, the antenna
must be located with the Gateway module or, if remotely located, an external surge suppressor
must be provisioned.
2.8
Copper Ethernet Cable Installation
The Kona Macro Gateway Ethernet port may be used on a temporary basis for commissioning
and maintenance or may be permanently connected for backhaul. When the port is not in use,
the weatherproof protective cap must be installed. When the port is permanently connector for
backhaul, a proper water-tight mating connector specified in Table 2 must be used.
The Ethernet cable must have minimum 24 AWG conductors and shall be rated for outdoor
application according to local and national electrical codes.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 16 of 34
3 Commissioning and Monitoring
3.1
Required Equipment
The following equipment is required for commissioning and monitoring the Kona Macro
Gateway.
1. A laptop running Windows XP/Vista/7.
2. A Cat5 or better Ethernet cable.
3.2
Procedure
Once the DC power and GPS and LoRa RF antenna connections are in place the Kona Macro
Gateway may be commissioned.
1. Connect an Ethernet cable between the Host PC and the bulkhead copper Ethernet
connector (RJ45). For a PoE powered installation, a PoE power injector may be required.
2. Apply DC power to the Kona Macro Gateway. The initial current draw is expected to be
greater than 0.1A. If there is no current, the polarity of the DC power cable connection
may be reversed or the power source may not be configured properly.
3. The Kona Macro Gateway supports DHCP; from the Gateway MAC ID label on the
enclosure, determine the IP address using your local DHCP tools.
4. Install the Tektelic Kona Factory Test Tool on a PC and follow the operating instructions
as detailed in the reference document T0004142_GUI_Instructions.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 17 of 34
4 Radio Compliance Statements
Federal Communications Commission
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1.
2.
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of
the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antennas used for this
transmitter must be installed to provide a separation distance of at least 80 cm from all persons and must not be colocated or operating in conjunction with any other antenna or transmitter.
Industry Canada
This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two
conditions:
1.
2.
This device may not cause interference, and
This device must accept any interference, including interference that may cause undesired operation of the device.
This radio transmitter (certification number) has been approved by Industry Canada to operate with the antenna types listed
below with the maximum permissible gain indicated. Antenna types not included in this list, having a gain greater than the
maximum gain indicated for that type, are strictly prohibited for use with this device.
The required antenna impedance is 50 ohms.
Only antenna with maximum gain of 8dBi can be used for the LoRa radios of this product if the cable insertion loss at 900 MHz
is 0.5dB or more for 1 carrier operation at 28.5dBm or 2dB or more for 2 carrier operation at 30dBm total. Antenna(s) shall
be installed to location providing a separation distance of at least 31.5 inches (80 cm) from any human body.
During product operation, always keep a separation distance of at least 31.5 inches (80 cm) from any connected antenna(s).
Before servicing the product, the antenna(s) or cables, turn off the transmission function or the unit power if you have to get
closer than the minimum separation distance..
The 3G/4G modem antenna maximum allowed gain including cable loss shall be in accordance with the following table:
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 18 of 34
Technology
Band
Frequency
(MHz)
LTE
13
17
25
850
1900
BC0
BC1
BC10
1850–1910
1710–1755
824–849
777–787
704–716
1850–1915
1850–1910
1710–1755
824–849
824–849
1850–1910
824–849
1850–1910
817–824
UMTS
GSM
CDMA
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Maximum
Antenna Gain
(dBi)
3.0
6.0
3.0
6.0
6.0
3.0
3.0
6.0
3.0
3.0
3.0
3.0
3.0
3.0
Version 1.1
Page 19 of 34
5 Description du produit
5.1
Vue d'ensemble
La passerelle Macro Kona est une passerelle LoRaWAN IoT qui prend en charge la gamme
complète des canaux US902-928. La plate-forme Kona est conçue pour supporter une multitude
de configurations de déploiement dans un environnement extérieur. L'architecture matérielle
prend en charge une ou deux antennes LoRa, une antenne GPS, une alimentation d'entrée CC
directe ou Power over Ethernet (PoE) et des options de backhaul, y compris Ethernet en cuivre,
Ethernet optique et 3G / 4G sans fil. Le tableau présente les modèles Kona Macro Gateway
actuellement disponibles.
Kona Macro Gateway Maquette
Maque
tte
Product
Code
T0004142
T0004470
T0004250
T0004251
T0004252
T0004537
Description
KONA MACRO
KONA MACRO, DC
POWER, 3G/4G
KONA MACRO, DC
POWER, 2X LORA,
3G/4G
KONA MACRO,
OPTICAL & DC
POWER
KONA MACRO,
OPTICAL & DC
POWER, 2X LORA
KONA MACRO, DC
POWER, 2X LORA
GPS
Ant.
Direct
DC
Power
Optical
Copper
Eth.
3G/4G
Ant.
LoRa
Ant.
La figure illustre le facteur de forme externe de la passerelle commune; Les différences entre
les différents modèles sont limitées à la disposition de la cloison de raccordement. La figure
illustre les dispositions de la cloison pour les modèles Kona Gateway.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 20 of 34
Kona Macro Gateway Dimensions Communes
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 21 of 34
Kona Macro Gateway Disposition des cloisons
5.2
Connecteurs
Le champ du connecteur Kona Gateway est détaillé dans la Figure pour le modèle T0004250.
Tous les connecteurs ne sont pas présents sur d'autres modèles. Le connecteur d'alimentation
CC est remplacé par un connecteur de puissance / fibre DC hybride sur des modèles qui
prennent en charge la capacité de rétroaction de fibre comme avec le modèle T0004252 décrit
en détail à la figure.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 22 of 34
GPS
Antenna
DC Power
2 pin CPC
LoRa RF
Antenna 1
LED
Terre de
protection
LoRa RF
Antenna 0
Ethernet
Cuivre
Enclosure
Évacuation
3G/4G
Modem
Antenna
Kona Macro Gateway T0004250 Champ du connecteur
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 23 of 34
GPS
Antenna
DC Power /
Fiber Hybrid
LoRa RF
Antenna 1
LED
Terre de
protection
LoRa RF
Antenna 0
Enclosure
Évacuation
Ethernet
Cuivre
Kona Macro Gateway T0004252 Champ du connecteur
Toutes les interconnexions du module Kona Gateway sont situées sur la paroi inférieure. Les
connecteurs RF sont résistants à l'eau lorsqu'ils sont désaccouplés, mais tous les autres
connecteurs doivent être munis de connecteurs correspondants ou couverts par le capuchon de
protection fourni lorsqu'ils ne sont pas utilisés afin d'être étanches. Les types de connecteurs et
leurs connecteurs correspondants sont répertoriés dans le Tableau.
Kona Macro Gateway Types de connecteurs d'interface
Interface
QTY
Connector Type
Mating Connector
LoRa Antenna Ports
1 or 2
N-Type femelle
Standard d'industrie N-Type male
3G/4G Modem
Backhaul Antenna Port
0 or 1
N-Type femelle
Standard d'industrie N-Type male
Fileté, circulaire, RJ-45
Shenzhen Chogori Technology Co., Ltd.
approved mating connector (p/n
33000111-02 or equivalent)
Fileté, circulaire, 2
Shenzhen Chogori Technology Co., Ltd.
approved mating connector (p/n
Copper Ethernet Port
Direct DC Power Input
Port
0 or 1
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 24 of 34
Hybrid Direct DC
Power/Fiber Ethernet
Port
0 or 1
contact DC power
23002211-02, or equivalent)
Harting Hybrid DC Power
/ Optical connector
Harting Technology Group approved
mating connector
GPS Port
N-Type femelle
Standard d'industrie N-Type male
Terre de protection
Borne de terre de
protection du châssis
Standard d'industrie 2-hole lug, 1/4 x 0.75”
spacing
5.3
Caractéristiques
Les spécifications de Kona Macro Gateway sont énumérées dans le Tableau.
Kona Macro Gateway Caractéristiques
Attribute
Caractéristiques
Dimensions
222.2mm x 101mm x 287.3mm
Poids
5.1 kg
Température
d'utilisation
-40°C to 60°C Au niveau de la mer Y compris la charge solaire
Humidité relative
10% to 100%
Altitude de
fonctionnement
-60 m to 4,000 m
Alimentation, Direct DC
48 VDC nominal, plage de fonctionnement de 37 à 57 VDC après un seuil de
démarrage maximal de 42 V. Alimentation référencée au sol positive ou
négative. SELV source requise. Protection maximale contre les surintensités
d'entrée 10A.
Alimentation, PoE
Consommation
d'énergie
Conditions
météorologiques
Conformité
réglementaire
Protection contre les
surtensions
802.3 à la classe 2, classe 4, mode A ou mode B, mais limité à une longueur
de câble maximale de 3 m et une tension de sortie PSE minimale de 56 V.
L'alimentation à quatre piles est prise en charge et préférable, et elle doit
satisfaire aux spécifications de fonctionnement de la classe 4 de type 2 pour
la longueur du câble.
35 W maximum, 1,0 A maximum avec alimentation DC directe
34 W maximum, 0,6 A maximum avec PoE
UL Type 6 (IP-67)
CSA/UL 60950-1 & CSA/UL 60950-22
FCC Pt. 15 Class B
Toutes les interfaces sont protégées aux niveaux primaires, à l'exception du
port d'antenne du modem 3G / 4G qui prend en charge uniquement le
montage de l'antenne locale ou nécessite un coupe-circuit externe.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 25 of 34
6 Installation
6.1
Précautions de sécurité
•
L'installation, le fonctionnement et l'entretien de la passerelle Macro Kona doivent être
effectués uniquement par un technicien qualifié et formé, conscient de tous les dangers.
•
La passerelle Macro Kona doit être installée dans un lieu d'accès restreint (de sorte que le
contact de la passerelle par des personnes non desservies n'est pas probable).
•
La Kona Macro Gateway peut devenir chaude au toucher en fonctionnement normal à des
températures ambiantes élevées. La température de surface de la passerelle peut atteindre
90 ° C.
•
La passerelle Macro Kona ne comporte aucune pièce interne pouvant être réparée. Le
module Gateway ne doit être ouvert que par un centre de service TEKTELIC agréé.
•
Toutes les pratiques d'installation doivent être conformes aux codes électriques locaux et
nationaux.
•
Ne pas travailler sur le système pendant les périodes d'activité de la foudre.
•
La passerelle Macro Kona est considérée comme un équipement connecté en permanence.
La connexion à la terre de protection (c'est-à-dire la borne à deux trous à la masse du
châssis) est toujours requise.
•
Assurez-vous que la connexion à la terre de protection Kona Macro Gateway est terminée
correctement avant la connexion de toute autre interface.
•
La passerelle Macro Kona contient une protection contre les surtensions primaires sur le
port d'alimentation CC direct, le port Ethernet en cuivre, le port d'antenne GPS et les ports
d'antenne RF LoRa. Les protecteurs contre la foudre primaires ont la capacité de combler la
frontière d'isolement d'interface pendant les surtensions. Assurez-vous que la connexion à
la terre de protection est toujours en place.
•
Assurez-vous que la passerelle Kona Macro, ses antennes et ses structures de support sont
bien sécurisées pour éliminer tout risque physique pour les personnes ou les biens. La
passerelle doit être montée de manière sûre conformément aux instructions de montage
avant toute connexion et utilisation du câble.
•
La passerelle Macro Kona ne contient pas de dispositif de déconnexion de l'alimentation; Un
dispositif de déconnexion facilement accessible doit être incorporé en externe à la
passerelle Kona Macro.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 26 of 34
•
La passerelle Kona Macro à courant continu doit être alimentée par un dispositif de
protection contre les surintensités d'entrée dont la valeur ne dépasse pas 10 A. La
protection contre les surintensités doit avoir la capacité d'interruption de courant
appropriée pour la source d'alimentation et doit être incorporée dans le ou les conducteurs
non mis à la terre ) De l'alimentation Kona Macro Gateway DC.
•
For the direct DC power feed option, the DC positive pin must be at positive potential
relative to the DC negative pin. If the polarity is reversed, the unit will not sustain damage
but will not operate until the connection polarity is corrected.
•
Bien que la passerelle Macro Kona puisse être alimentée par une entrée CC directe ou par
une alimentation via Ethernet (PoE), l'utilisation simultanée de l'alimentation des deux
entrées peut entraîner un fonctionnement inattendu et doit être évitée.
•
La source d'alimentation Kona Macro Gateway doit répondre aux exigences SELV.
6.2
Déballage et inspection
Les éléments suivants doivent être pris en compte lors du déballage d'une nouvelle passerelle
Kona Macro.
Inspectez le carton d'expédition et signalez tout dommage important à TEKTELIC.
Le déballage doit être effectué dans un endroit propre et sec lorsque possible.
Ne jetez pas la boîte d'expédition ou les inserts en mousse comme ils seront nécessaires
si une unité est retournée pour réparation ou reconfiguration.
6.3
Matériel requis pour l'installation
Les outils suivants sont nécessaires pour installer le module Kona Macro Gateway:
Ensemble de douilles métriques de 6 points et entraînement de la clé dynamométrique.
Composé antioxydant (NO-OX-ID, Penetrox, Noalox, Ox-Gard ou équivalent).
Une petite brosse métallique.
Un chiffon propre.
Kit de bande anti-intempéries pour les connecteurs
Weatherproofing Kit, WK-101 recommandé).
RF
(Scotch
Wireless
Colliers de montage de taille appropriée pour le montage de poteau ou des vis ou
boulons appropriés (quatre dimensions M8) avec tous les ancres requis selon la
construction de mur pour le montage mural.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 27 of 34
6.4
Montage Kona Macro Gateway
Kona Macro Gateway est conçu pour être monté sur un poteau ou un mur vertical à l'aide d'un
support de montage. Le support de montage est une pièce unique qui se verrouille sur la face
arrière de la passerelle en utilisant le matériel fourni (quatre boulons M6x1.0 - 14 mm avec
rondelles plates et étoile) comme illustré à la figure. Le module passerelle doit être orienté avec
le connecteur Face vers le bas, vers la terre.
Assurez-vous que la structure sur laquelle la passerelle est montée est sécurisée et capable de
supporter une charge mortelle d'au moins 136 kg. La zone ci-dessous doit être exempte de tout
obstacle à l'entrée du câble.
Module Kona avec support de montage
La procédure de montage mural Kona Macro Gateway est la suivante:
Visser le support mural au module Gateway à l'aide des boulons et rondelles fournis.
Installez 2 boulons M8 fournis dans le mur à un espacement de 139,7 mm, laissant les
têtes audacieuses faisant saillie avec un écart de 2 mm de la surface du mur.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 28 of 34
Accrochez la passerelle Macro Kona avec le support des deux boulons en insérant les
fentes en trou de serrure en haut du support sur les 2 boulons et en serrant les boulons.
Insérez et serrez deux boulons M8 supplémentaires fournis par le site à travers les trous
au bas du support.
La procédure de montage de la passerelle Kona Macro Gateway est la suivante:
Vissez le support de montage mural au module Gateway à l'aide des boulons et
rondelles fournis.
Pendant le support temporaire de la passerelle avec support, installez les deux colliers
de fixation fournis, un par chacun des points de fixation de la bride supérieure et
inférieure.
6.5 Installation du câble de masse
La passerelle Macro Kona est considérée comme un équipement connecté en permanence et
nécessite un conducteur de terre de protection (PEG) connecté en permanence. La connexion
au sol de terre de protection est faite par un ergot de double trou de 1/4 x 0,75" au point de
terminaison du sol illustré à la Figure. Le calibre du câble de masse doit être au minimum de 10
AWG.
Le système de mise à la terre Kona Macro Gateway doit respecter les codes électriques locaux
et nationaux. Le conducteur de mise à la terre de protection terminé au point de douille à
double trou est obligatoire et doit être la première connexion à la passerelle Macro Kona
pendant l'installation. Le bon acheminement et la terminaison de ce câble sont essentiels à la
robustesse des performances de résistance à la foudre; Dans les installations à haute sensibilité,
on s'efforcera de minimiser l'inductance de connexion et la résistance au sol.
Les étapes d'installation des câbles de terre sont les suivantes:
•
Lissez légèrement la surface de la surface de moulage au sol avec une brosse métallique
fine pour enlever la couche d'oxyde.
•
Utilisez un chiffon propre pour enlever les débris de cette surface.
•
Enduire immédiatement la surface de contact d'une fine couche de composé antioxydant.
•
Installez le câble de masse à travers son ergot à 2 trous sur la borne de mise à la terre du
châssis en utilisant les deux boulons fournis 1/4 - 20 x 1/2"avec rondelles plates et
étoile, serré à 10,4 Nm.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 29 of 34
Connexion à la masse du châssis
6.6
Installation du câble d'alimentation CC direct
En fonction du modèle, l'alimentation CC continue de la passerelle Macro Kona peut se
terminer par un connecteur en plastique circulaire à deux broches dédié (CPC) ou un
connecteur optique hybride à trois broches avec connecteur optique. L'alimentation continue
en courant continu est isolée du châssis (terre) à l'exception des capteurs de surtension
primaires. Un conducteur de l'alimentation en courant continu est normalement référencé à la
terre à l'extérieur de la passerelle Kona Macro (généralement à la source d'alimentation par
convention).
Le câble d'alimentation CC doit être homologué pour une utilisation en extérieur
conformément aux codes électriques locaux et nationaux.
Le connecteur CC continu du CPC doit être conforme au tableau et doit suivre la polarité du
signal indiquée à la figure.
Noir
DC négatif
Keyed DC Power
Connector (CPC)
Blanc
DC Positif
DC Positif
Kona Macro User Guide
TEKTELIC Communications Inc.
DC négatif
T0004279_UG
Confidential
Version 1.1
Page 30 of 34
Raccordement du connecteur CPC à courant continu direct Polarité
Le connecteur d'alimentation CC continu hybride doit être conforme au tableau et doit suivre la
polarité du signal identifiée sur la figure Bien que ce connecteur supporte un troisième fil pour
une connexion au sol, ce sol est complémentaire et ne remplace pas le câble de terre de
principe terminé à Le point de mise à la terre du châssis à deux trous.
Masse du châssis
vert
Noir
DC négatif
DC Positif
Masse du
DC négatif
châssis
Connecteur d'alimentation DC à clé (Hybrid)
Blanc
DC Positif
Connecteur hybride Raccordement direct CC Polarité
6.7
Installation du câble RF
L'installation de la passerelle nécessitera la connexion à une antenne GPS, à une ou deux
antennes RF LoRa et, éventuellement, à une antenne modem 3G / 4G. Les câbles RF se fixent
aux connecteurs N-Type au bas de la passerelle Kona Macro. Couplez les connecteurs à 1,7 à 2,3
Nm. L'interface de connecteur N-Type à un câble n'est pas étanche à l'eau et doit être collée
pour être utilisée à l'extérieur. TEKTELIC recommande l'utilisation d'un adhésif Scotch Wireless
Weatherproofing Kit, WK-101. Suivez les procédures d'enregistrement décrites par le
fournisseur de ce système de bandes.
Notez que le port d'antenne du modem 3G / 4G n'est pas protégé contre les surtensions et que,
par conséquent, l'antenne doit être située avec le module Gateway ou, si elle est située à
distance, un parafoudre externe doit être installé.
6.8
Installation du câble Ethernet en cuivre
Le port Ethernet Kona Macro Gateway peut être utilisé à titre temporaire pour la mise en
service et la maintenance ou peut être connecté en permanence pour le backhaul. Lorsque le
port n'est pas utilisé, le capuchon de protection contre les intempéries doit être installé.
Lorsque le port est en permanence un connecteur pour le backhaul, un connecteur approprié
étanche à l'eau spécifié dans le tableau doit être utilisé.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 31 of 34
Le câble Ethernet doit avoir un minimum de conducteurs 24 AWG et doit être évalué pour une
utilisation en extérieur conformément aux codes électriques locaux et nationaux.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 32 of 34
7 Mise en service et surveillance
7.1
Équipement requis
Les équipements suivants sont nécessaires pour la mise en service et la surveillance de la
passerelle Macro Kona.
•
Un ordinateur portable fonctionnant sous Windows XP / Vista / 7.
•
Câble Ethernet Cat5 ou supérieur.
7.2
Procédure
Une fois que l'alimentation CC et les connexions d'antenne RF GPS et LoRa sont en place, la
passerelle Macro Kona peut être mise en service.
•
Connectez un câble Ethernet entre le PC hôte et le connecteur Ethernet cuivre de
cloison (RJ45). Pour une installation alimentée en PoE, un injecteur PoE peut être
nécessaire.
•
Appliquez l'alimentation CC à la passerelle Kona Macro. On s'attend à ce que le tirage de
courant initial soit supérieur à 0,1 A. S'il n'y a pas de courant, la polarité de la connexion
du câble d'alimentation CC peut être inversée ou la source d'alimentation peut ne pas
être configurée correctement.
•
La passerelle Macro Kona prend en charge DHCP; À partir de l'étiquette d'identification
MAC de la passerelle sur le boîtier, déterminez l'adresse IP à l'aide de vos outils DHCP
locaux.
•
Installez l'outil de test Tektelic Kona Factory sur un PC et suivez les instructions
d'utilisation détaillées dans le document de référence T0004142_GUI_Instructions.
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Version 1.1
Page 33 of 34
8 Déclarations de conformité à la radio
Industrie Canada
Cet appareil est conforme aux normes RSS d'Industrie Canada exemptées de licence. Son fonctionnement est soumis aux
deux conditions suivantes:
1.
2.
Cet appareil ne doit pas provoquer d'interférences et
Cet appareil doit accepter toute interférence, y compris les interférences pouvant entraîner un fonctionnement
indésirable de l'appareil.
Cet émetteur radio (numéro de certification) a été approuvé par Industrie Canada pour fonctionner avec les types d'antennes
énumérés ci-dessous avec le gain maximal autorisé indiqué. Les types d'antennes non inclus dans cette liste, ayant un gain
supérieur au gain maximal indiqué pour ce type, sont strictement interdits avec ce périphérique.
L'impédance d'antenne requise est de 50 ohms.
Seule une antenne avec un gain maximal de 8dBi peut être utilisée pour les radios LoRa de ce produit si la perte d'insertion de
câble à 900 MHz est de 0,5dB ou plus pour une opération de porteuse à 28,5dBm ou 2dB ou plus pour un fonctionnement de
2 porteurs à 30dBm au total. Une ou plusieurs antennes doivent être installées à un emplacement situé à au moins 31,5
pouces (80 cm) de tout corps humain.
Pendant le fonctionnement du produit, conservez toujours une distance de séparation d'au moins 31,5 cm (80 cm) de toute
antenne connectée. Avant de réparer le produit, la ou les antennes ou les câbles, désactivez la fonction de transmission ou la
puissance de l'unité si vous devez vous rapprocher de la distance de séparation minimale.
Le gain maximal admissible de l'antenne du modem 3G / 4G, y compris la perte de câble, doit être conforme au tableau
suivant:
Technology
Band
Frequency
(MHz)
LTE
13
17
25
850
1900
BC0
BC1
BC10
1850–1910
1710–1755
824–849
777–787
704–716
1850–1915
1850–1910
1710–1755
824–849
824–849
1850–1910
824–849
1850–1910
817–824
UMTS
GSM
CDMA
Kona Macro User Guide
TEKTELIC Communications Inc.
T0004279_UG
Confidential
Gain
maximum
d'antenne
(dBi)
3.0
6.0
3.0
6.0
6.0
3.0
3.0
6.0
3.0
3.0
3.0
3.0
3.0
3.0
Version 1.1
Page 34 of 34

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Modify Date                     : 2017:03:24 18:18:40-06:00
Create Date                     : 2017:03:24 16:06:17-06:00
Metadata Date                   : 2017:03:24 18:18:40-06:00
Creator Tool                    : Acrobat PDFMaker 10.1 for Word
Document ID                     : uuid:ebbefd63-78b3-4b75-88bf-8c5e927fe967
Instance ID                     : uuid:ebe99241-236c-4109-ac68-86e02565e7f1
Subject                         : 7
Format                          : application/pdf
Title                           : 2150_RRH_SDS
Creator                         : Tom Danshin
Producer                        : Adobe PDF Library 10.0
Keywords                        : 2150_RRH_SDS
Source Modified                 : D:20170324220608
Company                         : Tektelic Communications Inc.
Doc Rev                         : 0.4
Page Count                      : 34
Page Layout                     : OneColumn
Author                          : Tom Danshin
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ALEPT0004279