TEKTELIC COMMUNICATIONS INC. Document type: User Guide Document number: T0005370_UG Document version: 0.5 Document Status: Approved Product name: Kona All-in-One Home Sensor Product codes: See Table 1       TEKTELIC Communications Inc. 7657 10th Street NE Calgary, AB, Canada  T2E 8X2 Phone: (403) 338-6900  © 2018 TEKTELIC Communications Inc., All rights reserved.  All products, names and services are trademarks and registered trademarks of their respective companies.  Disclaimer: Material contained in this document is subject to change without notice. The material herein is solely for information purposes and does not represent a commitment by TEKTELIC or its representatives. TEKTELIC has prepared the information contained in this document solely for use by its employees, agents, and customers. Dissemination of this information and/or concepts to other parties is prohibited without the prior written consent of TEKTELIC. In no event will TEKTELIC be liable for any incidental or consequential damage in connection with the furnishing, performance or use of this material.  TEKTELIC reserves the right to revise this publication in accordance with formal change control procedures defined by TEKTELIC.
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 2 of 32   Revision History Version Date Status Editor Comments 0.1 Jan. 31, 2018 Obsolete D. Smith First release 0.2 Feb. 12, 2018 Obsolete Z. Herasymiuk Added Compliance Statements 0.3 Feb. 14, 2018 Obsolete D. Smith Added extra safety disclaimers, installation equipment, and removed network server provisioning guide. 0.4 Mar 29, 2018 Obsolete K. Strom Added section for battery replacement 0.5 Apr. 02, 2018 Approved S. M. Added more battery information.
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 4 of 32   Table of Contents 1 Product Description ................................................................................................................. 6 1.1 Overview .......................................................................................................................... 6 1.2 Physical Interfaces ............................................................................................................ 7 1.3 Specifications.................................................................................................................... 8 2 What is in the Box .................................................................................................................. 10 2.1 Product and installation material................................................................................... 10 3 Installation ............................................................................................................................. 11 3.1 Safety Precautions .......................................................................................................... 11 3.2 Unpacking and Inspection .............................................................................................. 11 3.3 Required Equipment for Installation .............................................................................. 11 3.4 Kona All-In-One Home Sensor Mounting ....................................................................... 11 3.5 External Connector Cable Installation ............................................................................ 12 4 Power UP and Commissioning and Monitoring .................................................................... 13 4.1 Required Equipment ...................................................................................................... 13 4.2 Power Up/Down Procedure ........................................................................................... 13 5 Operation, Alarms & Management ....................................................................................... 14 5.1 Configuration .................................................................................................................. 14 5.2 Default Configuration ..................................................................................................... 14 5.3 LED Behaviour ................................................................................................................ 14 6 Battery Replacement ............................................................................................................. 15 7 Compliance Statements ......................................................................................................... 17 8 Description du produit........................................................................................................... 18 8.1 Aperçu ............................................................................................................................ 18 8.2 Interfaces physiques ...................................................................................................... 19 8.3 Caractéristiques .............................................................................................................. 20 9 Qu'est ce qu'il y a dans la boite ............................................................................................. 22 9.1 Produit et matériel d'installation ................................................................................... 22 10 Installation ............................................................................................................................. 23
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 5 of 32   10.1 Précautions de sécurité .................................................................................................. 23 10.2 Déballage et inspection .................................................................................................. 23 10.3 Équipement requis pour l'installation ............................................................................ 23 10.4 Kona tout-en-un Accueil capteur de montage ............................................................... 23 10.5 Installation du câble de connecteur externe ................................................................. 24 11 Mise sous tension et mise en service et surveillance............................................................ 26 11.1 Équipement requis ......................................................................................................... 26 11.2 Marche / Arrêt Procédure .............................................................................................. 26 12 Fonctionnement, alarmes et gestion .................................................................................... 27 12.1 Configuration .................................................................................................................. 27 12.2 Configuration par défaut ................................................................................................ 27 12.3 Comportement des LED ................................................................................................. 27 13 Remplacement de la Batterie ................................................................................................ 29 14 Déclarations de conformité ................................................................................................... 31
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 6 of 32   1 Product Description 1.1 Overview The Kona All-in-One Home Sensor is a multi-purpose LoRaWAN IoT sensor packed into a very small  form  factor.  The  Home  Sensor  is  ideal  for  monitoring  and  reporting  temperature, humidity, light, shock and open/closed doors and window in the home environment. Additional sensing features such as leak and motion detection, as well counting pulses from an external device  are  also  support  with  the  appropriate  Home  Sensor  model.  Table  1  presents  the currently available Kona All-in-One Home Sensor models. Table 1: Kona All-in-One Home Sensor Models Product Code Description RF Region T0004885 HOME SENSOR MODULE, NA, PIR NA T0004886 HOME SENSOR MODULE, NA, EXTERNAL CONNECTION NA T0004893 HOME SENSOR MODULE, NA, BASE NA  The Kona All-in-One Home Sensor line supports the following sensing applications:  Movement  Detection:  Configurable  triggers  allow  the  sensor  to  detect  if  it  has  been moved.   Digital On/Off Sensing: An internal magnetic switch or external contact can be used to monitor on/off states and count events.  Light detection: On board light sensor is able to report the presence or absence of light using a configurable intensity threshold.  Temperature  and  Humidity  Measurements:  The  Home  Sensor  is  able  to  monitor  and report the temperature and humidity of its local environment.  Moisture / Leak Detection: Ability to detect pooling water for flood and leak detection.  Motion Detection (PIR): Equipped sensors can detect people moving within the sensors field of view. Figure 1 illustrates the Kona All-in-One Home Sensors external form-factor. All models share the same mechanical form-factor.
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 7 of 32    Figure 1: Kona All-in-One Home Sensor   1.2 Physical Interfaces Figure 2 illustrates the I/O layout for the Kona All-in-One Home Sensor. All models share the same layout, though only functional I/O is exposed on the case.
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 8 of 32    Figure 2: Kona All-in-One Home Sensor External Connector I/O Layout Connector types and their mating connectors are listed in Table 2.   Table 2: Kona All-in-One Home Sensor Interface Connector Types Interface QTY Connector Type Mating Connector External Connector 0 or 1 JST B2B-ZR(LF)(SN) JST ZHR-2  1.3 Specifications The Kona All-in-One Home Sensor specifications are listed in Table 3.    Humidity Sensor Aperture  LoRa LED  Magnetic Switch  (External Connector) PIR Lens  (PIR model only) Light Sensor  System LED
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 9 of 32   Table 3: Kona All-in-One Home Sensor Specifications  Attribute Specification Dimensions 42 mm (1.65”) wide x 42 mm (1.65”) deep x 14mm (0.55”) tall Weight 20g (0.71 oz) Operating Temperature 10°C to 40°C (50°F to 104°F)  Ingress Protection IP30 Battery CR2450 (replaceable) Panasonic (Model CR2450) Sony (Model CR2450B) EVE Energy (Model CR2450) FDK Corporation (Model CR2450) Regulatory Compliance IEC 60950-1 (CE) ETSI EN 300 019-2-1, 300 019-2-2 ETSI EN 300 019-2-3, 300 019-2-4 FCC 15.247 RSS-247 FCC 15.209 RSS-Gen
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 10 of 32   2 What is in the Box 2.1 Product and installation material  Kona All-In-One Home Sensor  Mounting Bracket
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 11 of 32   3 Installation 3.1 Safety Precautions  The Kona All-in-One Home Sensor is intended for indoor use only.  The Kona All-in-One Home Sensor contains a lithium coin cell battery.  NEVER  allow  small  children  near  batteries:  if  battery  is  swallow,  immediately  notify doctor.  To  reduce  risk  of  fire,  explosion  or  chemical  burns:  replace  only  with  approved  3V CR2450  coin  batteries;  DO  NOT  recharge,  disassemble,  heat  above  100°C  (212°F)  or incinerate.  The  Kona  All-in-One  Home  Sensor  requires  an  external  magnet  for  use  with  the  internal magnetic switch.  Keep magnets away from all children. Small magnets can pose a serious choking hazard. If multiple magnets are swallowed, contact doctor immediately. 3.2 Unpacking and Inspection The  following  should  be  considered  during  the  unpacking  of  a  new  Kona  All-in-One  Home Sensor.  1. Inspect the shipping carton and report any significant damage to TEKTELIC. 2. Unpacking should be conducted in a clean and dry location when possible. 3. Do  not  discard  the  shipping  box  or  foam  inserts  as  they  will  be  required  if  a  unit  is returned for repair or re-configuration.  3.3 Required Equipment for Installation  There are no tools required for Kona All-in-One Home Sensor installation. 3.4 Kona All-In-One Home Sensor Mounting Kona All-in-One Home Sensor is designed to be mounted using the supplied mounting bracket. The bracket can be attached using screws or tape (not included).  When mounting on a vertical surface, ensure that the Home Sensor will not be orientated with the case retaining screws towards the ceiling. This could cause the Home Sensor to accidently slip off the mount and fall. There are no orientation concerns when the Home Sensor is mounted to a horizontal surface.
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 12 of 32   3.5 External Connector Cable Installation The Kona All-in-One Home Sensor with External Connect installation requires connection to the external device. The external device cable attaches to the 2-pin connector located on the top of the Home Sensor.   Figure 3: Kona All-in-One Home Sensor External Connector Signals Figure 3: Kona All-in-One Home Sensor External Connector  shows the external connector signal locations.  The  connector  is  designed  to  be  attached  to  an  open-drain  output,  however  the signal line can  also be driven with digital signals at 1.8V  logic levels. Connection  cable length should NOT exceed 3 meters. Do not connect to an outdoor device. Signal  Connection Ground Connection
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 13 of 32   4 Power UP and Commissioning and Monitoring 4.1 Required Equipment No special equipment is required to power on the Kona All-in-One Home Sensor.  4.2 Power Up/Down Procedure Once the sensor information has been added to the NS, pull the tab to engage the battery.  To reset or turn off the device the battery must be removed, refer to the Battery Replacement Section.
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 14 of 32   5 Operation, Alarms & Management   5.1 Configuration The  Kona  All-In-One  home  sensor  supports  a  full  range  of  Over-the-Air  (OTA)  configuration options.  Specific  technical  details  are  available  in  the  Home  Sensor  Technical  Reference Manual. All configuration commands need to be sent OTA during a sensor’s downlink windows.  5.2 Default Configuration  The default configuration on the Home Sensor is: o Report Temperature and Humidity every one (1) hour. o Report Battery Voltage every twenty-four (24) hours. o Report actuation of the digital input element every one (1) actuation. 5.3 LED Behaviour During Boot and Join Procedure:  Both LED’s will come on briefly when power is first applied.   After a small delay ( < 1 second ) the LED’s will turn off and one of them will blink briefly. o If the System LED blinks, then all health checks on the board passed. o If the LoRa LED blinks, then one of the health checks failed. Consider replacing the battery, or moving the sensor to an environment within temperature range.  Immediately after, the Join  Procedure will  begin. During the  time the System LED will blink continuously until the sensor has joined a network.  The LoRa LED will now blink whenever LoRa activity occurs on the sensor (Transmitting or Receiving packets) During normal operation:  The  LoRa  LED  will  blink  whenever  LoRa  activity  occurs  on  the  sensor (Transmitting  or Receiving packets)  The System LED can be controlled via the downlink command interface.
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 15 of 32   6  Battery Replacement The Kona All-in-One Home Sensor is powered by a standard CR2450 coin cell. Use only approved CR2450 cells when replacing the battery:  Panasonic (Model CR2450)  Sony (Model CR2450B)  EVE Energy (Model CR2450)  FDK Corporation (Model CR2450) In order to access the battery the two screws securing the case must be removed. The screws are accessible on the bottom of the sensor case and require a T-3 Torx screwdriver. Opening the case:  Remove the two T-3 screws on the bottom of the case   While holding the sensor with the bottom facing up, remove the bottom of the case  With the bottom removed, the coin cell holder is accessible   Remove the coin cell from the holder by gently pinching and lifting the end of the cell indicated in the image below
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.5 TEKTELIC Communications Inc.  Confidential  Page 16 of 32     Place the new cell in the holder, first hooking the top of the cell under the two metal fingers as shown below o The top of the coin cell is marked with a + symbol indicating the positive terminal. This positive terminal must face up when replacing the cell   Push the other end of the cell into the holder until it clips positively into the holder  When reinserting battery ensure the metal hooks on the battery holder are above the battery before pushing it in. Failure to do so will damage the power leads on the sensor.
7 Compliance Statements Federal Communications Commission This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  1. This device may not cause harmful interference, and  2. This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:   Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help.  To comply with FCC exposure limits for general population / uncontrolled exposure, this device should be installed at a distance of 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter.       Industry Canada This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions:  This device may not cause interference, and  This device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter (identify the device by certification number, or model number if (Category II) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. This device complies with IC radiation exposure limits set forth for an uncontrolled environment.  This device should be installed and operated with minimum distance 0.2 m between the radiator and your body.
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.4 TEKTELIC Communications Inc.  Confidential  Page 18 of 32   8 Description du produit 8.1 Aperçu Le capteur maison tout-en-un Kona est un capteur LoRaWAN IoT multi-usage compacté dans un très petit format. Le Home Sensor est idéal pour surveiller et signaler la température, l'humidité, la lumière, les chocs et les portes et fenêtres ouvertes / fermées dans l'environnement domestique. Des fonctions de détection supplémentaires telles que la détection de fuite et de mouvement, ainsi que le comptage des impulsions d'un appareil externe sont également pris en charge avec le modèle de capteur de domicile approprié. Le Tableau 1 présente les modèles de capteurs domestiques Kona tout-en-un actuellement disponibles. Tableau 1: Modèles de détecteurs de maison tout-en-un Kona Product Code Description RF Region T0004885 HOME SENSOR MODULE, NA, PIR NA T0004886 HOME SENSOR MODULE, NA, EXTERNAL CONNECTION NA T0004893 HOME SENSOR MODULE, NA, BASE NA  La  gamme  de  capteurs  domestiques  tout-en-un  Kona  prend  en  charge  les  applications  de détection suivantes:  Détection  de  mouvement:  Les  déclencheurs  configurables  permettent  au  capteur  de détecter s'il a été déplacé.  Détection numérique marche / arrêt: Un interrupteur magnétique interne ou un contact externe  peut  être  utilisé  pour  surveiller  les  états  marche  /  arrêt  et  compter  les événements.  Détection  de  la  lumière:  Le  capteur  de  lumière  embarqué  est  capable  de  signaler  la présence ou l'absence de lumière en utilisant un seuil d'intensité configurable.  Mesures de température et d'humidité: Le capteur Home est capable de surveiller et de signaler la température et l'humidité de son environnement local.  Détection  de  l'humidité  /  des  fuites:  Possibilité  de  détecter  l'eau  de  la  piscine  pour détecter les inondations et les fuites. •  Détection  de  mouvement  (PIR):  Les  capteurs  équipés  peuvent  détecter  les  personnes  se déplaçant dans le champ de vision des capteurs.
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.4 TEKTELIC Communications Inc.  Confidential  Page 19 of 32   La Figure 1 illustre le facteur de forme externe Kona All-in-One Home Sensors. Tous les modèles partagent le même facteur de forme mécanique.  Figure 1: Capteur maison Kona tout-en-un 8.2 Interfaces physiques La Figure 2 illustre la configuration des E / S pour le capteur Home Kona All-in-One. Tous les modèles partagent la même disposition, mais seules les E / S fonctionnelles sont exposées sur le boîtier.
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.4 TEKTELIC Communications Inc.  Confidential  Page 20 of 32    Figure 2: Disposition des E / S du connecteur externe Kona All-in-One Home Sensor Les types de connecteurs et leurs connecteurs correspondants sont répertoriés dans le Tableau 2.   Tableau 2: Types de connecteurs d'interface de capteur domestique tout-en-un Kona Interface QTY Type de connecteur Connecteur compatible Connecteur externe 0 or 1 JST B2B-ZR(LF)(SN) JST ZHR-2  8.3 Caractéristiques Les spécifications du capteur domestique tout-en-un Kona sont indiquées dans le tableau 3. Ouverture du capteur d'humidité LoRa LED  Interrupteur magnétique (Connecteur externe) Lentille PIR (modèle PIR uniquement)  Capteur de lumière LED système
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.4 TEKTELIC Communications Inc.  Confidential  Page 21 of 32   Tableau 3: Spécifications du capteur domestique tout-en-un Kona Attribut Spécification Dimensions 42 mm (1.65”) largeur x 42 mm (1.65”) profondeur x 14mm (0.55”) grand Poids 20g (0.71 oz) Température  de fonctionnement 10°C to 40°C (50°F to 104°F)  Protection  contre  la pénétration IP30 Batterie CR2450 (replaceable) Panasonic (modèle CR2450) Sony (modèle CR2450B) EVE Energy (modèle CR2450) FDK Corporation (modèle CR2450) Conformité réglementaire IEC 60950-1 (CE) ETSI EN 300 019-2-1, 300 019-2-2 ETSI EN 300 019-2-3, 300 019-2-4 FCC 15.247 RSS-247 FCC 15.209 RSS-Gen
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.4 TEKTELIC Communications Inc.  Confidential  Page 22 of 32   9 Qu'est ce qu'il y a dans la boite 9.1 Produit et matériel d'installation  Capteur maison Kona tout-en-un  Support de montage
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.4 TEKTELIC Communications Inc.  Confidential  Page 23 of 32   10 Installation 10.1 Précautions de sécurité  Le  capteur  Home  Kona  tout-en-un  est  conçu  pour  une  utilisation  en  intérieur uniquement.  Le capteur maison Kona tout-en-un contient une pile bouton au lithium. o Ne laissez JAMAIS de petits enfants à proximité des batteries: si la batterie est avalée, avertissez immédiatement le médecin. o Pour  réduire  les  risques  d'incendie,  d'explosion  ou  de  brûlures  chimiques: remplacez  uniquement par des  piles  3V CR2450;  NE  PAS  recharger,  démonter, chauffer au-dessus de 100 ° C (212 ° F) ou incinérer.  Le capteur  domestique tout-en-un Kona  nécessite un aimant externe pour l'utilisation avec l'interrupteur magnétique interne.  Gardez  les  aimants  à  l'écart  de  tous les  enfants. Les  petits aimants  peuvent  poser  un sérieux  risque  d'étouffement.  Si  plusieurs  aimants  sont  avalés,  contactez immédiatement un médecin. 10.2 Déballage et inspection Les  éléments  suivants  doivent  être  pris  en  compte  lors  du  déballage  d'un  nouveau  capteur domestique Kona tout-en-un. 1. Inspectez le carton d'expédition et signalez tout dommage important à TEKTELIC. 2. Le déballage doit être effectué dans un endroit propre et sec lorsque cela est possible. 3. Ne jetez pas la boîte d'expédition ou les inserts en mousse car ils seront nécessaires si une unité est retournée pour réparation ou reconfiguration.  10.3 Équipement requis pour l'installation Aucun outil n'est requis pour l'installation du capteur domestique tout-en-un Kona. 10.4 Kona tout-en-un Accueil capteur de montage Le capteur domestique tout-en-un Kona est conçu pour être monté à l'aide du support de montage fourni. Le support peut être fixé à l'aide de vis ou de ruban adhésif (non inclus).
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.4 TEKTELIC Communications Inc.  Confidential  Page 24 of 32   Lors du montage sur une surface verticale, assurez-vous que le capteur de la maison n'est pas orienté avec les vis de retenue du boîtier vers le plafond. Cela pourrait provoquer le glissement accidentel du capteur Home sur le support et tomber. Il n'y a pas de problème d'orientation lorsque le capteur d'ambiance est monté sur une surface horizontale. 10.5 Installation du câble de connecteur externe L'installation  du  capteur  Home  Tout-en-un  Kona  avec  connexion  externe  nécessite  une connexion à l'appareil externe. Le câble du périphérique externe se branche sur le connecteur à 2 broches situé sur le dessus du capteur Home.   Figure 3: Signaux de connecteurs externes Kona All-in-One Home Sensor Signal Connexion Connexion au sol
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.4 TEKTELIC Communications Inc.  Confidential  Page 25 of 32   Figure 3:  Le connecteur externe  Kona All-in-One Home Sensor indique  les emplacements des signaux  du  connecteur  externe.  Le  connecteur  est  conçu  pour  être  connecté  à  une  sortie  à drain ouvert, mais la ligne de signal peut également être pilotée avec des signaux numériques à des  niveaux  logiques  de  1,8  V.  La  longueur  du  câble  de  connexion  ne  doit  PAS  dépasser  3 mètres. Ne pas connecter à un appareil extérieur.
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.4 TEKTELIC Communications Inc.  Confidential  Page 26 of 32   11 Mise sous tension et mise en service et surveillance 11.1 Équipement requis Aucun équipement spécial n'est requis pour alimenter le capteur domestique tout-en-un Kona. 11.2 Marche / Arrêt Procédure Une fois les informations du capteur ajoutées au NS, tirez sur la languette pour engager la batterie. Pour réinitialiser ou éteindre l'appareil, la batterie doit être retirée, reportez-vous à la section Remplacement de la batterie.
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.4 TEKTELIC Communications Inc.  Confidential  Page 27 of 32   12 Fonctionnement, alarmes et gestion  12.1 Configuration The  Kona  All-In-One  home  sensor  supports  a  full  range  of  Over-the-Air  (OTA)  configuration options.  Specific  technical  details  are  available  in  the  Home  Sensor  Technical  Reference Manual. All configuration commands need to be sent OTA during a sensor’s downlink windows.  12.2 Configuration par défaut La configuration par défaut sur le capteur Home est:  Signaler la température et l'humidité toutes les (1) heures.  Signalez la tension de la batterie toutes les vingt-quatre (24) heures.  Signaler l'actionnement de l'élément d'entrée numérique à chaque actionnement (1). 12.3 Comportement des LED Au cours de la procédure de démarrage et de jointure:  Les deux voyants s'allument brièvement lors de la première mise sous tension.  Après  un  court  délai  (<1  seconde),  les  voyants  s'éteindront  et  l'un  d'eux  clignotera brièvement. o Si le voyant System clignote, tous les contrôles de santé de la carte sont passés. o Si le voyant LoRa clignote, l'un des contrôles d'intégrité a échoué. Envisagez de remplacer la batterie ou de déplacer le capteur dans un environnement dans la plage de température.  Immédiatement  après,  la  procédure  de  jonction  commence.  Pendant  ce  temps,  le voyant System clignote en continu jusqu'à ce que le capteur rejoigne un réseau.  La LED LoRa clignote à chaque fois que l'activité LoRa se produit sur le capteur (paquets d'émission ou de réception) En fonctionnement normal:  La LED LoRa clignote lorsque l'activité LoRa se produit sur le capteur (paquets d'émission ou de réception)
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.4 TEKTELIC Communications Inc.  Confidential  Page 28 of 32    Le  voyant  System  peut  être  contrôlé  via  l'interface  de  commande  de  liaison descendante.
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.4 TEKTELIC Communications Inc.  Confidential  Page 29 of 32   13 Remplacement de la Batterie Le capteur Home Kona tout-en-un est alimenté par une pile bouton standard CR2450. Utilisez uniquement des cellules CR2450 approuvées lors du remplacement de la batterie:  Panasonic (modèle CR2450)  Sony (modèle CR2450B)  EVE Energy (modèle CR2450)  FDK Corporation (modèle CR2450) Pour accéder à la batterie, les deux vis de fixation du boîtier doivent être retirées. Les vis sont accessibles sur le fond du boîtier du capteur et nécessitent un tournevis Torx T-3. Ouverture du boîtier:   Retirez les deux vis T-3 sur le fond du boîtier   Tout en maintenant le capteur avec la partie inférieure vers le haut, retirez le bas du boîtier  Avec le fond enlevé, le porte-cellule est accessible   Retirez la pile bouton du support en pinçant doucement et en soulevant l'extrémité de la cellule indiquée dans l'image ci-dessous
Kona All-in-One Home Sensor User Guide  T0005370_UG                            Version 0.4 TEKTELIC Communications Inc.  Confidential  Page 30 of 32     Placez la nouvelle cellule dans le support, en accrochant d'abord le haut de la cellule sous les deux doigts métalliques comme indiqué ci-dessous o Le haut de la pile bouton est marqué d'un symbole + indiquant la borne positive. Ce terminal positif doit être orienté vers le haut lors du remplacement de la cellule   Poussez l'autre extrémité de la cellule dans le support jusqu'à ce qu'elle se clipse positivement dans le support  Lors de la réinsertion de la batterie, assurez-vous que les crochets métalliques du support de la batterie sont au-dessus de la batterie avant de l'enfoncer. Sinon, vous risquez d'endommager les fils d'alimentation du capteur.
14 Déclarations de conformité Commission fédérale des communications Cet appareil est conforme à la partie 15 des règles FCC. Le fonctionnement est soumis aux deux conditions suivantes:  1. Cet appareil ne peut pas causer d'interférences nuisibles, et  2. Cet appareil doit accepter toute interférence reçue, y compris les interférences susceptibles de provoquer un fonctionnement indésirable. Les changements ou modifications non expressément approuvés par la partie responsable de la conformité peuvent annuler l'autorité de l'utilisateur à utiliser l'équipement. Cet équipement a été testé et déclaré conforme aux limites d'un appareil numérique de classe B, conformément à la partie 15 des règles de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une installation résidentielle. Cet équipement génère des utilisations et peut émettre de l'énergie radiofréquence et, s'il n'est pas installé et utilisé conformément aux instructions, peut provoquer des interférences nuisibles aux communications radio. Cependant, il n'y a aucune garantie que des interférences ne se produiront pas dans une installation particulière. Si cet équipement cause des interférences nuisibles à la réception radio ou télévision, ce qui peut être déterminé en éteignant et en rallumant l'équipement, l'utilisateur est encouragé à essayer de corriger l'interférence par l'une des mesures suivantes:  • Réorienter ou déplacer l'antenne de réception. • Augmentez la distance entre l'équipement et le récepteur. • Connectez l'équipement à une prise d'un circuit différent de celui auquel le récepteur est connecté. • Consulter le revendeur ou un technicien radio / TV expérimenté pour obtenir de l'aide.  Pour respecter les limites d'exposition RF FCC / IC pour la population générale / exposition incontrôlée, les antennes utilisées pour cet émetteur doivent être installées de manière à fournir une distance de séparation d'au moins 20 cm par rapport à toutes les personnes et ne doivent pas être co-localisées toute autre antenne ou émetteur. Ce produit doit être installé par des techniciens RF qualifiés.       Industrie Canada Cet appareil est conforme aux normes RSS exemptes de licence d'Industrie Canada. L'opération est soumise aux deux conditions suivantes:  1. Cet appareil ne peut pas causer d'interférences, et 2. Cet appareil doit accepter toute interférence, y compris les interférences susceptibles de provoquer un fonctionnement indésirable de l'appareil.  En vertu des règlements d'Industrie Canada, cet émetteur radio ne peut fonctionner qu'avec une antenne de type et un gain maximum (ou moindre) approuvé pour l'émetteur par Industrie Canada. Pour réduire les interférences radio potentielles avec d'autres utilisateurs, le type d'antenne et son gain doivent être choisis de manière à ce que la puissance isotrope rayonnée équivalente (e.i.r.p.) ne soit pas supérieure à celle nécessaire pour une communication réussie.  Cet émetteur radio (identifiez l'appareil par un numéro de certification ou un numéro de modèle si (Catégorie II) a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous avec le gain maximal admissible et l'impédance d'antenne requise pour chaque type d'antenne indiqué. Il est strictement interdit d'utiliser cet appareil avec un gain supérieur au gain maximal indiqué pour ce type Cet appareil est conforme aux limites d'exposition aux radiations IC définies pour un environnement non contrôlé.  Cet appareil doit être installé et utilisé avec une distance minimale de 0,2 m entre le radiateur et votre corps.