TENDA TECHNOLOGY W330A Wireless N300 Ceiling Access Point User Manual

SHENZHEN TENDA TECHNOLOGY CO., LTD. Wireless N300 Ceiling Access Point

Users Manual

Install Guide 1 Open the Package z Wireless N300 Ceiling Access Point*1 z Ethernet Cable*1 z Bracket*1 z Screw*4 z Expansion Bolt*4 z Position Paster*1 z Install Guide*1 If any item is incorrect, missing, or damaged, please contact your reseller for immediate replacement.   2 Get to Know the Device LED Light  Status  Description SYS Solid  The device is starting. Blinking  The device is functioning normally. Off The device is receiving no electric power or the LED light is turned off on the web page of the AC. 
 Button & Interface Function Description LAN A10/100M auto-negotiationRJ-45port that can: a) connect to a PoE device for both data and electric power transmission; b) connectto a PC, switch or any other Ethernet device for data communication only. RST Press and hold it with a needle for 6 seconds. The device will be restored to factory default settings in 1 minute. 3 Install the Device Step 1Prepare the following:  Step 2Adhere the position paster onto the ceiling where your AP will be installed.
 Step 3Borefour 25~30mm deep holes by using the hammer drill (6mm drill bit)according to the marks on the position paster.  Step 4Strike the expansion bolts into the holes with the rubber hammer, and then fix the bracket with the provided screws.  Step 5Attach the device to the bracket and make sure it is aligned correctly.
 4 Connect the Device Step 1Connect the AP’s LAN port to an IEEE 802.3af-compliant PoE switch’s PoE port with an Ethernet cable.  Step 2 Connect an access controller to the core switch with an Ethernet cable.  Step 3 Connect other devices and check the network topology.
 Tips z As AC500 will configure the AP,there is no need to configure the AP. If you want to know the configuration method, please refer to the user guide of AC500.   z When used alone (without being managed by an access controller), this AP’s default SSID is Tenda_XXXXXX,where XXXXXX is the last six characters of its MAC addresson the label on the back of AP.   ©2014 Shenzhen Tenda Technology Co., Ltd. All rights reserved. This documentation (including pictures, images, and product specifications, etc.) is for reference only. To improve internal design, operational function, and/or reliability,Tenda reserves the right to make changes to the products described in this document without obligation to notify any person or organization of such revisions or changes.
5 S  CE ThisintedevNOTunainte FCCThistwo musopeThisdevreasequand comparttelevuse— R— ISafety aMark Warns is a Classrference, in ice compliesTE: (1) The uthorized mrference, it i C Statemens device comconditions: st accept anration. s equipmentice, pursuansonable proipment gene used in acmmunicationsticular instavision recepr is encouraReorient or Increase theand Emiing s B productwhich cases with EU 19manufacturemodificationss recomment mplies with P(1) This deny interferent has been tnt to Part 1otection agaerates, usesccordance ws. Howeverllation. If thption, which aged to try torelocate thee separationission St. In a dome the user m999/5/EC. er is not ress to this ended to use Part 15 of thevice may nnce receivedtested and f15 of the Fainst harmfs and can rwith the instr, there is nhis equipmecan be deto correct thee receiving a between thStatememestic enviromay be requponsible for equipment. a shielded he FCC Rulenot cause had, including found to comFCC Rules. ul interferenadiate radioructions, mano guaranteent does catermined bye interferencntenna. he equipmenent onment, thisuired to takeany radio o(2) To avRJ45 cable.es. Operatioarmful interfinterferencemply with theThese limitnce in a reo frequency ay cause hae that interfause harmfy turning thee by one of nt and receivs product me adequate or TV interfervoid unnece. on is subjectference, ande that may ce limits for ats are desigesidential inenergy andarmful interfrference willful interferene equipmentthe followingver. may cause rmeasures. rence causeessary radiat to the followd (2) this decause undesa Class B dgned to pronstallation. d, if not instaference to rl not occur nce to radit off and ong measuresradio This ed by ation wing evice sired igital ovide This alled radio in a o or , the s:
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —  Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. NOTE: (1) The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. (2) To avoid unnecessary radiation interference, it is recommended to use a shielded RJ45 cable.