THALES DIS AlS Deutschland EHS6-A GSM/WCDMA Module User Manual EHS6 A Rev 2x

Gemalto M2M GmbH GSM/WCDMA Module EHS6 A Rev 2x

Contents

EHS6-A_User Manual_Rev 2

       M2M.GEMALTO.COM Cinterion ®  EHS6-A Hardware Interface Overview Version: 02.770 DocId: EHS6-A_HIO_v02.770
 EHS6-A Hardware Interface Overview EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary Cinterion®  Page 2 of 40 2  GENERAL NOTE  THE  USE  OF  THE  PRODUCT  INCLUDING  THE  SOFTWARE  AND  DOCUMENTATION (THE "PRODUCT") IS SUBJECT TO THE RELEASE NOTE PROVIDED TOGETHER WITH PRODUCT. IN ANY EVENT THE PROVISIONS OF THE RELEASE NOTE SHALL PREVAIL. THIS DOCUMENT CONTAINS INFORMATION ON GEMALTO M2M PRODUCTS. THE SPECIFICATIONS IN THIS DOCUMENT ARE SUBJECT  TO  CHANGE  AT  GEMALTO  M2M'S  DISCRETION.  GEMALTO  M2M  GMBH GRANTS A NONEXCLUSIVE RIGHT TO USE THE PRODUCT. THE RECIPIENT SHA LL NOT TRANSFER , COPY, MODIFY, TRANSLATE, REVERSE ENGINEER, CREATE  DERIVATIVE WORKS; DISASSEMBLE OR DECOMPILE  THE  PRODUCT  OR  OTHERWISE  USE  THE  PRODUCT  EXCEPT AS  SPECIFICALLY AUTHORIZED. THE PRODUCT AND THIS DOCUMENT ARE PROVIDED ON AN "AS IS" BASIS ONLY AND MAY CONTAIN DEFICIENCIES OR INADEQUACIES. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, GEMALTO M2M GMBH DISC LAIMS ALL WARRANTIES AND LIABILITIES. THE RECIPIENT UNDERTAKES FOR AN UNLIMITED PERIOD OF TIME TO OBSERVE SECRECY REGARDING  ANY  INFORMATION  AND  DATA  PROVIDED  TO  HIM  IN  THE  CONTEXT  OF  THE DELIVERY OF THE  PRODUCT. THIS GENERAL  NOTE SHALL  BE GOVERNED AND CONSTRUED ACCORDING TO GERMAN LAW. Copyright Transmittal,  reproduction,  dissemination  and/or  editing  of  this  document  as  well  as  utilization  of  its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved.  Copyright © 2014, Gemalto M2M GmbH, a Gemalto Company Document Name:  Cinterion ® EHS6-A Hardware Interface Overview   Version:  02.770 Date:  2014-08-13 DocId:  EHS6-A_HIO_v02.770 Status  Confidential / Preliminary
Cinterion® EHS6-A Hardware Interface Overview  Page 3 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary Trademark Notice Gemalto, the Gemalto logo, are trademarks and service marks of Gemalto and are registered in certain countries.  Microsoft  and  Windows  are  either  registered  trademarks  or  trademarks  of  Microsoft Corporation in the United States and/or other countries. All other registered trademarks or trademarks mentioned in this document are property of their respective owners.  Contents 40 Contents 1 Introduction ........................................................................................................................... 7 1.1 Key Features at a Glance .......................................................................................... 7 1.2 EHS6-A System Overview ....................................................................................... 12 2 Interface Characteristics .................................................................................................... 13 2.1 Application Interface ................................................................................................ 13 2.1.1 USB Interface ............................................................................................ 13 2.1.2 Serial Interface ASC0 ................................................................................ 14 2.1.3 Serial Interface ASC1 ................................................................................ 14 2.1.4 UICC/SIM/USIM Interface ......................................................................... 15 2.1.5 Analog Audio Interface .............................................................................. 17 2.1.6 Digital Audio Interface ............................................................................... 17 2.1.7 GPIO Interface .......................................................................................... 17 2.1.8 I2C Interface .............................................................................................. 18 2.1.9 SPI Interface ............................................................................................. 18 2.1.10 HSIC Interface ........................................................................................ 18 2.1.11 PWM Interfaces ....................................................................................... 19 2.1.12 Pulse Counter ......................................................................................... 19 2.1.13 Status LED .............................................................................................. 19 2.1.14 Fast Shutdown ........................................................................................ 19 2.2 RF Antenna Interface ............................................................................................... 20 2.2.1 Antenna Installation ................................................................................... 21 2.3 Sample Application .................................................................................................. 22 3 Operating Characteristics .................................................................................................. 24 3.1 Operating Modes ..................................................................................................... 24 3.2 Power Supply .......................................................................................................... 24 4 Mechanical Dimensions, Mounting and Packaging ......................................................... 26 4.1 Mechanical Dimensions of EHS6-A ......................................................................... 26 5 Regulatory and Type Approval Information ...................................................................... 28 5.1 Directives and Standards ........................................................................................ 28
 EHS6-A Hardware Interface Overview EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 5.2 SAR requirements specific to portable mobiles ....................................................... 31 5.3 Reference Equipment for Type Approval ................................................................. 31 5.4 Compliance with FCC and IC Rules and Regulations ............................................. 32 6 Document Information ........................................................................................................ 34 6.1 Revision History ....................................................................................................... 34 6.2 Related Documents ................................................................................................. 34 6.3 Terms and Abbreviations ......................................................................................... 34 6.4 Safety Precaution Notes .......................................................................................... 38 7 Appendix .............................................................................................................................. 39 7.1 List of Parts and Accessories .................................................................................. 39
Cinterion® EHS6-A Hardware Interface Overview  Page 5 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary  Tables 111 Tables Table 1:  Signals of the SIM interface (SMT application interface)............................... 14Table 2:  GPIO lines and possible alternative assignment............................................ 16Table 3:  Return loss in the active band........................................................................ 19Table 4:  Overview of operating modes ........................................................................ 23Table 5:  Directives ....................................................................................................... 27Table 6:  Standards of North American type approval.................................................. 27Table 7:  Standards of European type approval............................................................ 27Table 8:  Requirements of quality ................................................................................. 28Table 9:  Standards of the Ministry of Information Industry of the  People’s Republic of China............................................................................ 28Table 10:  Toxic or hazardous substances or elements with defined concentration  limits............................................................................................................... 29Table 11:  List of parts and accessories.......................................................................... 38Table 12:  Molex sales contacts (subject to change)...................................................... 39
Cinterion® EHS6-A Hardware Interface Overview  Page 6 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary  Figures 111 Figures Figure 1:  EHS6-A system overview............................................................................... 10Figure 2:  USB circuit ..................................................................................................... 11Figure 3:  Serial interface ASC0..................................................................................... 12Figure 4:  Serial interface ASC1..................................................................................... 13Figure 5:  External UICC/SIM/USIM card holder circuit ................................................. 15Figure 6:  Schematic diagram of EHS6-A sample application........................................ 22Figure 7:  EHS6-A– top and bottom view....................................................................... 25Figure 8:  Dimensions of EHS6-A (all dimensions in mm) ............................................. 26Figure 9:  Reference equipment for Type Approval ....................................................... 31
Cinterion® EHS6-A Hardware Interface Overview  Page 7 of 41 1.1 Key Features at a Glance 10 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 1  Introduction 10 1  Introduction This document1 describes the hardware of the Cinterion® EHS6-A module. It helps you quickly retrieve  interface  specifications,  electrical  and  mechanical  details  and  information  on  the requirements to be considered for integrating further components. 1.1  Key Features at a Glance Feature ImplementationGeneral  Frequency bands GSM/GPRS/EDGE: Quad band 850/900/1800/1900MHz UMTS/HSPA+: Five band 800/850/900/1900/2100MHz GSM class Small MS Output power +33dBm ±1dB for EGSM850 +30dBm ±1dB for GSM1900  +27dBm ±1dB for EGPRS 850(8-PSK, 1 Tx slot)  +24dBm ±1dB for EGPRS 850(8-PSK, 2 Tx slot)  +22dBm ±1dB for EGPRS 850(8-PSK, 3 Tx slot)  +21dBm ±1dB for EGPRS 850(8-PSK, 4 Tx slot)  +26dBm ±1dB for GPRS 1900(8-PSK, 1 Tx slot) +23dBm ±1dB for EGPRS 1900(8-PSK, 2 Tx slot)  +21dBm ±1dB for EGPRS 1900(8-PSK, 3 Tx slot)  +20dBm ±1dB for EGPRS 1900(8-PSK, 4 Tx slot)  +33dBm ±1dB forGPRS 850(GMSK, 1 Tx slot)  +30dBm ±1dB for GPRS 850(GMSK,2 Tx slot)  +28dBm ±1dB for GPRS 850(GMSK, 3 Tx slot)  +27dBm ±1dB for GPRS 850(GMSK, 4 Tx slot) +30dBm ±1dB for GPRS 1900(GMSK, 1 Tx slot) +27dBm ±1dB for GPRS 1900(GMSK, 2 Tx slot) +25dBm ±1dB for GPRS19050(GMSK, 3 Tx slot) +24dBm ±1dB for GPRS 1900(GMSK, 4Tx slot) +24dBm ±1dB for UMTS Band 2 +24dBm ±1dB for UMTS Band 5 Power supply 3.3V to 4.5VOperating temperature (board temperature) Normal operation: -30°C to +85°C Extended operation: -40°C to +90°C Physical Dimensions: 27.6mm x 25.4mm x 2.2mm Weight: approx. 3.5g                                                  1  .    The  document  is  effective  only  if  listed  in  the  appropriate  Release  Notes  as  part  of  th  e  technical documentation delivered with your Gemalto M2M product.
Cinterion® EHS6-A Hardware Interface Overview  Page 8 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary RoHS All hardware components fully compliant with EU RoHS Directive HSPA features  3GPP Release 6, 7 DL 7.2Mbps, UL 5.7MbpsHSDPA Cat.8 / HSUPA Cat.6 data rates Compressed mode (CM) supported according to 3GPP TS25.212 UMTS features  3GPP Release 4 PS data rate – 384 kbps DL / 384 kbps UL CS data rate – 64 kbps DL / 64 kbps UL  Feature ImplementationGSM/GPRS/EGPRS features Data transfer GPRS: •  Multislot Class 12 •  Full PBCCH support •  Mobile Station Class B •  Coding Scheme 1 – 4 EGPRS: •  Multislot Class 12 •  EDGE E2 power class for 8 PSK •  Downlink coding schemes – CS 1-4, MCS 1-9 •  Uplink coding schemes – CS 1-4, MCS 1-9 •  SRB loopback and test mode B •  8-bit, 11-bit RACH •  PBCCH support •  1 phase/2 phase access procedures •  Link adaptation and IR •  NACC, extended UL TBF •  Mobile Station Class B CSD: •  V.110, RLP, non-transparent •  9.6kbps •  USSD SMS Point-to-point MT and MOCell broadcast Text and PDU mode Storage: SIM card plus SMS locations in mobile equipment Audio Speech codecs:•  Half rate HR (ETS 06.20) •  Full rate FR (ETS 06.10)  •  Enhanced full rate EFR (ETS 06.50/06.60/06.80) •  Adaptive Multi Rate AMR 7 different ringing tones/melodies Software
Cinterion® EHS6-A Hardware Interface Overview  Page 9 of 41 1.1 Key Features at a Glance 10 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary AT commands Hayes 3GPP TS 27.007, TS 27.005, Gemalto M2M AT commands for RIL compatibility  Java™ Open Platform Java™ Open Platform with •  Java™ profile IMP-NG & CLDC 1.1 HI •  Secure data transmission via HTTPS/SSL •  Multi-threading programming and multi-application execution Major  benefits:  seamless  integration  into  Java  applications,  ease  of programming,  no  need  for  application  microcontroller,  extremely cost-efficient hardware and software design – ideal platform for industrial GSM applications. The memory space available for Java programs is around 8 MB in the flash file system and around 6MB RAM. Application code and data share the space in the flash file system and in RAM.
Cinterion® EHS6-A Hardware Interface Overview  Page 10 of 41 1.1 Key Features at a Glance 10 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary  Feature ImplementationMicrosoft™ compatibility RIL for Pocket PC and Smartphone SIM Application Toolkit SAT Release 99 Firmware update Generic update from host application over ASC0 or USB modem.  Interfaces Module interface Surface mount device with solderable connection pads (SMT application interface). Land grid array (LGA) technology ensures high solder joint reliability and provides the possibility to use an optional module mounting socket. For more information on how to integrate SMT modules see also [3]. This application note comprises chapters on module mounting and application layout issues as well as on additional SMT application development equipment. USB USB 2.0 High Speed (480Mbit/s) device interface, Full Speed (12Mbit/s) compliant 2 serial interfaces  ASC0 (shared with GPIO lines):•  8-wire modem interface with status and control lines, unbalanced, asynchronous •  Adjustable baud rates: 1,200bps to 921,600bps •  Autobauding: 1,200bps to 230,400bps •  Supports RTS0/CTS0 hardware flow control. •  Multiplex ability according to GSM 07.10 Multiplexer Protocol. ASC1 (shared with GPIO lines): •  4-wire, unbalanced asynchronous interface •  Adjustable baud rates: 1,200bps to 921,60bps •  Autobauding: 1,200bps to 230,400bps •  Supports RTS1/CTS1 hardware flow control Audio 1 analog interface (with microphone feeding)1 digital interface (PCM), shared with GPIO lines UICC interface Supported SIM/USIM cards: 3V, 1.8V GPIO interface 14 GPIO lines shared with ASC0 lines, LED signalling, PWM functionality, fast shutdown and pulse counter 4 GPIO lines shared with PCM interface4 GPIO lines shared with ASC1, SPI and HSIC interfaces I2C interface Supports I2C serial interfaceHSIC interface High-Speed Inter-Chip (HSIC) interface for USB chip-to-chip interconnect including Link Power Management (LPM) lines shared with GPIO lines SPI interface Serial peripheral interface, shared with GPIO linesAntenna interface pads 50   Power on/off, Reset
Cinterion® EHS6-A Hardware Interface Overview  Page 11 of 41 1.1 Key Features at a Glance 10 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary Power on/off Switch-on by hardware signal AUTO_ON and ONSwitch-off by AT command  Switch off by hardware signal FST_SHDN instead of AT command Automatic switch-off in case of critical temperature and voltage conditions Reset Orderly shutdown and reset by AT commandEmergency reset by hardware signal EMERG_RST  Feature ImplementationSpecial features  Real time clock Timer functions via AT commandsPhonebook SIM and phoneTTY/CTM support Integrated CTM modemEvaluation kit  Evaluation module EHS6-A module soldered onto a dedicated PCB that can be connected to an adapter in order to be mounted onto the DSB75. DSB75 DSB75 Development Support Board designed to test and type approve Gemalto M2M modules and provide a sample configuration for application engineering. A special adapter is required to connect the EHS6-A evaluation module to the DSB75.
Cinterion® EHS6-A Hardware Interface Overview Page 12 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 1.2  EHS6-A  System  Overview 10 1.2  EHS6-A System Overview
Cinterion® EHS6-A Hardware Interface Overview  Page 13 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 2  Interface  Characteristics 22 2  Interface Characteristics EHS6-A is equipped with an SMT application interface that connects to the external application. The SMT application interface incorporates the various application interfaces as well as the RF antenna interface.  2.1  Application Interface 2.1.1  USB Interface EHS6-A supports a USB 2.0 High Speed (480Mbit/s) device interface that is Full Speed (12Mbit/s) compliant. The USB interface is primarily intended for use as command and data interface and for downloading firmware.  The external application is responsible for supplying the VUSB_IN line. This line is used for cable detection only. The USB part (driver and transceiver) is supplied by means of BATT+. This is because EHS6-A is designed as a self-powered device compliant with the “Universal Serial Bus Specification Revision 2.0”1.  1) All  serial (including RS) and pull-up resistors for data lines are implemented. 2) If the USB interface is operated in High Speed mode (480MHz), it is recommended to take special care routing the data lines USB_DP and USB_DN. Application layout should in this case implement a differential impedance of 90 ohms for proper signal integrity. Figure 2:  USB circuit To  properly  connect  the  module's  USB  interface  to  the  external  application,  a  USB  2.0 compatible connector and cable or hardware design is required. Furthermore, the USB modem driver distributed with EHS6-A needs to be installed.                                                  1 .  The specification is ready for download on http://www.usb.org/developers/docs/ VBUS DP DN VREG (3V075)BATT+ USB_DP 2) lin. reg.GND Module Detection only VUSB_IN USB part 1) RING0 Host wakeupUSB_DN 2) RSRSSMT
Cinterion® EHS6-A Hardware Interface Overview  Page 14 of 41 2.1 Application Interface 22 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 2.1.2  Serial Interface ASC0 EHS6-A offers an 8-wire unbalanced, asynchronous modem interface ASC0 conforming to  ITU-T V.24 protocol DCE signalling. The electrical characteristics do not comply with ITU-T V.28. The significant levels are 0V (for low data bit or active state) and 1.8V (for high data bit or inactive state).  EHS6-A is designed for use as a DCE. Based on the conventions for DCE-DTE connections it communicates with the customer application (DTE) using the following signals: • Port TXD @ application sends data to the module’s TXD0 signal line •  Port RXD @ application receives data from the module’s RXD0 signal line  Figure 3:  Serial interface ASC0 Features: •  Includes the data lines TXD0 and RXD0, the status lines RTS0 and CTS0 and, in addition, the modem control lines DTR0, DSR0, DCD0 and RING0. •  ASC0  is  designed  for  controlling  GSM/UMTS  voice  calls,  transferring  data  and  for controlling the module with AT commands. •  Full multiplexing capability allows the interface to be partitioned into virtual channels. •  The RING0 signal serves to indicate incoming calls and other types of URCs (Unsolicited Result Code). It can also be used to send p ulses to the host application, for example to wake up the application from power saving state.  •  Configured for 8 data bits, no parity and 1 stop bit.  •  ASC0 can be operated at fixed bit rates from 1,200bps up to 921,600bps. •  Autobauding supports bit rates from 1,200bps up to 230,400bps. •  Supports RTS0/CTS0 hardware flow control. The hardware hand shake line RTS0 has an internal pull down  resistor  causing  a  low level  signal,  if t he  line  is n  ot  used  and  open. Although hardware flow control is recommended, this allows communication by using only RXD and TXD lines. •  Wake up from SLEEP mode by RTS0 activation (high to low transition). 2.1.3  Serial Interface ASC1 Four  EHS6-A  GPIO  lines  can  be  configured  as ASC1  interface  signals  to  provide  a  4-wire unbalanced, asynchronous  modem  interface ASC1  conforming  to  ITU-T V.24  protocol  DCE signalling. The electrical characteristics do not comply with ITU-T V.28. The significant levels are 0V (for low data bit or active state) and 1.8V (for high data bit or inactive state).
Cinterion® EHS6-A Hardware Interface Overview  Page 15 of 41 2.1 Application Interface 22 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary EHS6-A is designed for use as a DCE. Based on the conventions for DCE-DTE connections it communicates with the customer application (DTE) using the following signals: •  Port TXD @ application sends data to module’s TXD1 signal line •  Port RXD @ application receives data from the module’s RXD1 signal line  Figure 4:  Serial interface ASC1 Features •  Includes only the data lines TXD1 and RXD1 plus RTS1 and CTS1 for hardware han dshake.  •  On ASC1 no RING line is available. •  Configured for 8 data bits, no parity and 1 or 2 stop bits. •  ASC1 can be operated at fixed bit rates from 1,200 bps to 921,600 bps.  •  Autobauding supports bit rates from 1,200bps up to 230,400bps.  •  Supports RTS1/CTS1 hardware flow. The hardware hand shake line RTS0 has an internal pull  down  resistor  causing  a  low  level  signal,  if  the  line  is  not  used  and  open. Although hardware flow control is recommended, this allows communication by using only RXD and TXD lines. 2.1.4  UICC/SIM/USIM Interface EHS6-A has an integrated UICC/SIM/USIM interface compatible with the 3GPP 31.102 and ETSI 102 221. This is wired to the host interface in order to be connected to an external SIM card holder. Five pads on the SMT application interface are reserved for the SIM interface.  The UICC/SIM/USIM interface supports 3V and 1.8V SIM cards.  The CCIN signal serves to detect whether a tray (with SIM card) is present in the card holder. Using the CCIN signal is mandatory for compliance with the GSM 11.11 recommendation if the mechanical  design  of  the  host  application  allows  the  user  to  remove  the  SIM  card  during operation. To take advantage of this feature, an appropriate SIM card detect switch is required on the card holder. For example, this is true for the model supplied by Molex, which has been tested to operate with EHS6-A and is part of the Gemalto M2M reference equipment submitted for type approval. See Section 7.1 for Molex ordering numbers. Table 1:  Signals of the SIM interface (SMT application interface) Signal DescriptionGND Separate ground connection for SIM card to improve EMC.CCCLK Chipcard clock CCVCC SIM supply voltage.
Cinterion® EHS6-A Hardware Interface Overview  Page 16 of 41 2.1 Application Interface 22 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary CCIO Serial data line, input and output.CCRST Chipcard reset CCIN Input on the baseband processor for detecting a SIM card tray in the holder. If the SIM is removed during operation the SIM interface is shut down immediately to prevent destruction of the SIM. The CCIN signal is by default low and will change to highl evel if a SIM card is inserted. The CCIN signal is mandatory for applications that allow the user to remove the SIM card during operation.  The CCIN signal is solely intended for use with a SIM card. It must not be used for any other purposes. Failure to comply with this requirement may invalidate the type approval of EHS6-A. Note: No guarantee can be given, nor any liability accepted, if loss of data is encountered after removing  the  SIM  card  during  operation.  Also,  no  guarantee  can  be  given  for  properly initializing  any  SIM  card  that  the  user  inserts  after  having  removed  the  SIM  card  during operation. In this case, the application must restart EHS6-A. The figure below shows a circuit to connect an external SIM card holder.  Figure 5:  External UICC/SIM/USIM card holder circuit The total cable length between the SMT application interface pads on EHS6-A and the pads of the external SIM card holder must not exceed 100mm in order to meet the specifications of 3GPP TS 51.010-1 and to satisfy the requirements of EMC compliance. To avoid possible cross-talk from the CCCLK signal to the CCIO signal be careful that both lines are not placed closely next to each other. A useful approach is using a GND line to shield the CCIO line from the CCCLK line. SIMCCVCC CCRST CCIO CCCLK 220 nF 1 nF CCIN V180
Cinterion® EHS6-A Hardware Interface Overview  Page 17 of 41 2.1 Application Interface 22 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 2.1.5  Analog Audio Interface EHS6-A  has  an  analog  audio  interface  with  a  balanced  analog  microphone  input  and  a balanced  analog  earpiece  output. A  supply  voltage  and  an  analog  ground  connection  are provided at dedicated pads. 2.1.6  Digital Audio Interface EHS6-A digital audio interface (DAI) can be used to connect audio devices capable of pulse code modulation (PCM).  2.1.7  GPIO Interface EHS6-A  offers  a  GPIO  interface  with  22  GPIO  lines. The GPIO  lines are  shared with  other interfaces or functions: Fast shutdown (see Section 2.1.14), status LED (see Section 2.1.13), the PWM functionality (see Section 2.1.11), an pulse counter (see Section 2.1.12), ASC0 (see Section  2.1.2),  ASC1  (see  Section  2.1.3),  an  SPI  interface  (see  Section  2.1.9),  an  HSIC interface (see Section 2.1.10) and a PCM interface (see Section 2.1.11)  The  following  table  shows  the  configuration  variants  for  the  GPIO  pads.  All  variants  are mutually exclusive, i.e. a pad configured for instance as Status LED is locked for alternative usage. Table 2:  GPIO lines and possible alternative assignment GPIO Fast  Shutdown Status  LED PWM Pulse Counter ASC0 ASC1 SPI HSIC PCMGPIO1     DTR0       GPIO2     DCD0       GPIO3     DSR0  SPI_CLK   GPIO4 FST_SHDN            GPIO5  Status  LED           GPIO6   PWM2        GPIO7   PWM1        GPIO8    COUNTER        GPIO11           GPIO12           GPIO13           GPIO14           GPIO15           GPIO16      RXD1 MOSI AP_WAKEUP
Cinterion® EHS6-A Hardware Interface Overview  Page 18 of 41 2.1 Application Interface 22 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary GPIO17      TXD1 MISO HOST_ACTIVE  GPIO18      RTS1  CP_WAKEUP  GPIO19      CTS1 SPI_CS SUSPEND  GPIO20          TXDDAIGPIO21          RXDDAIGPIO22          TFSDAIGPIO23          SCLKGPIO24     RING0       After startup, the above mentioned alternative GPIO line assignments can be configured using AT commands (see [1]). The configuration is non-volatile and available after module restart. 2.1.8  I2C Interface I2C  is  a  serial,  8-bit  oriented  data  transfer  bus  for bit  rates  up  to  400kbps  in  Fast  mode.  It consists of two lines, the serial data line I2CDAT and the serial clock line I2CCLK. The module acts as a single master device, e.g. the clock I2CCLK is driven by the module. I2CDAT is a bi-directional line. Each device connected to the bus is software addressable by a unique 7-bit address,  and  simple  master/slave  relationships  exist  at  all  times.  The  module  operates  as mastertransmitter or as master-receiver. The customer application transmits or receives data only on request of the module. The I2C interface can be powered via the V180 line of EHS6-A. If connected to the V180 line, the I2C interface will properly shut down when the module enters the Power Down mode. Note: Good care should be taken when creating the PCB layout of the host application: The traces of I2CCLK and I2CDAT should be equal in length and as short as possible. 2.1.9  SPI Interface Four EHS6-A GPIO interface lines can be configured as Serial Peripheral Interface (SPI). The SPI is a synchronous serial interface for control and data transfer between EHS6-A and the external  application.  Only  one  application  can  be  connected  to  the  SPI  and  the  interface supports  only  master  mode. The  transmission  rates  are  up  to  6.5Mbit/s. The  SPI  interface comprises the two data lines MOSI and MISO, the clock line SPI_CLK a well as the chip select line SPI_CS. 2.1.10  HSIC Interface The (USB) High Speed Inter Chip Interface can be used between the module and an external application processor and is compliant to the High Speed USB 2.0 interface with 480Mbit/s. The maximum distance between module processor and external application processor should not exceed 100mm.
Cinterion® EHS6-A Hardware Interface Overview  Page 19 of 41 2.1 Application Interface 22 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary The HSIC interface comprises 6 lines: •  Two  signal  lines  (strobe  -  HSIC_STRB  -  and  data  -  HSIC_DATA)  are  used  in  a  source synchronous serial interface with a 240MHz clock to provide a 480Mbps USB interface. The HSIC_STRB and HSIC_DATA lines are high-speed signals and should be routed as 50  impedance traces. The trace length of these signals should be balanced to minimize timing skew and no longer as 100mm. •  Four signal lines for Link Power Management (LPM). For further power reduction, the USB HSIC interface supports LPM according to the USB 2.0 standard. The LPM defines power management  states  and  mechanisms  to  affect  state  changes  that  are  used  b  y  the AP_WAKEUP and CP_WAKEUP signal lines to efficiently manage bus and system power. To take advantage of the LPM feature, two further signals are needed to  support power management state transitions - the SUSPEND and HOST_ACTIVE signals. 2.1.11  PWM Interfaces The GPIO6 and GPIO7 interface lines can be configured as Pulse Width Modulation interface lines PWM1 and PWM2. The PWM interface lines can be used, for example, to connect buzzers. The PWM1 line is shared with GPIO7 and the PWM2 line is shared with GPIO6 (for GPIOs see Section 2.1.7). GPIO and PWM functionality are mutually exclusive. 2.1.12  Pulse Counter The  GPIO8  line  can  be  configured  as  pulse  counter  line  COUNTER.  The  pulse  counter interface can be used, for example, as a clock (for GPIOs see Section 2.1.7). 2.1.13  Status LED The GPIO5 interface line can be configured to drive a status LED that indicates different operating modes of the module (for GPIOs see Section 2.1.7). GPIO and LED functionality are mutually exclusive. 2.1.14  Fast Shutdown The  GPIO4  interface  line  can  be  configured  as  fast  shutdown  signal  line  FST_SHDN. The configured FST_SHDN line is an active low control signal and must be applied for at least 10 milliseconds.  If  unused  this  line  can  be  left  open  because  of  a  configured  internal  pull-up resistor.
Cinterion® EHS6-A Hardware Interface Overview  Page 20 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 2.2  RF  Antenna  Interface 22 2.2  RF Antenna Interface The RF interface has an impedance of 50 . EHS6-A is capable of sustaining a total mismatch at the antenna line without any damage, even when transmitting at maximum RF power. The  external  antenna  must  be  matched  properly  to  achieve  best  performance  regarding radiated power, modulation accuracy and harmonic suppression. Antenna matching networks are not included on the EHS6-A module and should be placed in the host application if the antenna does not have an impedance of 50 . Regarding the return loss EHS6-A provides the following values in the active band: Table 3:  Return loss in the active band State of module Return loss of module Recommended return loss of applicationReceive > 8dB > 12dBTransmit  not applicable  > 12dB
Cinterion® EHS6-A Hardware Interface Overview  Page 21 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 2.2  RF  Antenna  Interface 22 2.2.1  Antenna Installation The antenna is connected by soldering the antenna pad (ANT_GSM, i.e., pad #59) and its neighboring ground pads (GND, i.e., pads #58 and #60) directly to the application’s PCB. The antenna  pad  is  the  antenna  reference  point  (ARP)  for  EHS6-A.  All  RFd  ata  specified throughout this document is related to the ARP. The distance between the antenna ANT_GSM pad (#59) and its neighboring GND pads (#58, #60)  has  been  optimized  for  best  possible  impedance.  On  the  application  PCB,  special attention should be paid to these 3 pads, in order to prevent mismatch. The wiring of the antenna connection line, starting from the antenna pad to the application antenna should result in a 50  line impedance. Line width and distance to the GND plane needs to be optimized with regard to the PCB’s layer stack.  To prevent receiver desensitization due to interferences generated by fast transients like high speed clocks on the application PCB, it is recommended to realize the antenna connection line using embedded Stripline rather than Micro-Stripline technology.  For type approval purposes, the use of a 50  coaxial antenna connector (U.FL-R-SMT) might be necessary. In this case the U.FL-R-SMT connector should be placed as close as possible to EHS6-A‘s antenna pad.
Cinterion® EHS6-A Hardware Interface Overview  Page 22 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 2.3  Sample  Application 22 2.3  Sample Application Figure 6 shows a typical example of how to integrate a EHS6-A module with an application. Usage of the various host interfaces depends on the desired features of the application. The  analog  audio  interface  demonstrates  the  balanced  connection  of  microphone  and earpiece. This solution is particularly well suited for internal transducers. Because of the very low power consumption design, current flowing from any other source into the  module  circuit  must  be  avoided,  for  example  reverse  current  from  high  state  external control lines. Therefore, the controlling application must be designed to prevent reverse current flow. Otherwise there is the risk of undefined states of the module during startup and shutdown or even of damaging the module. Because of the high RF field density inside the module, it cannot be guaranteed that no self interference might  occur,  depending  on  frequency  and  the  applications  grounding  concept. The potential interferers may be minimized by placing small capacitors (47pF) at suspected lines (e.g. RXD0, RXT0, VDDLP, and ON).  While developing SMT applications it is strongly recommended to provide test points for certain signals, i.e., lines to and from the module - for debug and/or test purposes. The SMT application should allow for an easy access to these signals. For details on how to implement test points see [3]. The EMC measures are best practice recommendations. In fact, an adequate EMC strategy for an individual application is very much determined by the overall layout and, especially, the position of components. For example, mounting the internal acoustic transducers directly on the PCB eliminates the need to use the ferrite beads shown in the sample schematic.  Note: EHS6-A is not intended for use with cables longer than 3m. Disclaimer No warranty, either stated or implied, is provided on the sample schematic diagram shown in Figure  6  and  the  information  detailed  in  this  section. As  functionality  and  compliance  with national regulations depend to a great amount  on  the  used  electronic  components  and  the individual  application  layout  manufacturers  are  required  to  ensure  adequate  design  and operating safeguards for their products using EHS6-A modules. 2.3 Sample Application 22
Cinterion® EHS6-A Hardware Interface Overview Page 23 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary  Figure 6:  Schematic diagram of EHS6-A sample application 3  Operating  Characteristics 24
Cinterion® EHS6-A Hardware Interface Overview  Page 24 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 3  Operating Characteristics 3.1  Operating Modes The table below briefly summarizes the various operating modes referred to throughout the document.  Table 4:  Overview of operating modes Mode Function Normal operation GSM /  GPRS / UMTS /  HSPA SLEEP Power saving set automatically when no call is in progress and the USB connection  is  suspended  by  host  or  not  present  and  no  active communication via ASC0.  GSM /  GPRS / UMTS /  HSPA IDLE Power saving disabled or an USB connection not suspended, but no call in progress. GSM TALK/ GSM DATA Connection between two subscribers is in progress. Power consumption depends on the GSM network coverage and several connection settings (e.g. DTX off/on, FR/EFR/HR, hopping sequences and antenna connection). The following applies when power is to be measured in TALK_GSM mode: DTX off, FR and no frequency hopping. GPRS DATA GPRS  data  transfer  in  progress.  Power  consumption  depends  on network settings (e.g. power control level), uplink / downlink data rates and GPRS configuration (e.g. used multislot settings). EGPRS DATA EGPRS  data  transfer  in  progress.  Power  consumption  depends  on network settings (e.g. power control level), uplink / downlink data rates and EGPRS configuration (e.g. used multislot settings). UMTS TALK/ UMTS DATA UMTS data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate. HSPA DATA HSPA data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate. Power  Down Normal shutdown after sending the power down command. Only a voltage regulator is active for powering the RTC. Software is not active. Interfaces are not accessible. Operating voltage remains applied. Airplane  mode Airplane mode shuts down the radio part of the module, causes the module to log off from the GSM/GPRS network and disables all AT commands whose execution requires a radio connection. Airplane mode can be controlled by AT command (see [1]). 3.2  Power  Supply 24 3.2  Power Supply EHS6-A needs to be connected to a power supply at the SMT application interface - 2 lines BATT+, and GND. There are two separate voltage domains for BATT+: •  BATT+BB with a line for the general power management. •  BATT+RF with a line for the GSM power amplifier supply.
Cinterion® EHS6-A Hardware Interface Overview  Page 25 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary Please note that throughout the document BATT+ refers to both voltage domains and power supply lines - BATT+BB and BATT+RF. The power supply of EHS6-A has to be a single voltage source at BATT+BB and BATT+RF. It must be able to provide the peak current during the uplink transmission.  All the key functions for supplying power to the device are handled by the power management section of the analog controller. This IC provides the following features: •  Stabilizes the supply voltages for the baseband using low drop linear voltage regulators and a DC-DC step down switching regulator. •  Switches the module's power voltages for the power-up and -down procedures. •  SIM switch to provide SIM power supply.
Cinterion® EHS6-A Hardware Interface Overview  Page 26 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 4 Mechanical Dimensions, Mounting and Packaging 26 4  Mechanical Dimensions, Mounting and Packaging 4.1  Mechanical Dimensions of EHS6-A Figure 7 shows the top and bottom view of EHS6-A and provides an overview of the board's mechanical dimensions. For further details see Figure 8.   4.1 Mechanical Dimensions of EHS6-A 26 Figure 7:  EHS6-A– top and bottom viewProduct label Top view Bottom view
Cinterion® EHS6-A Hardware Interface Overview Page 27 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary  Figure 8:  Dimensions of EHS6-A (all dimensions in mm) 5 Regulatory and Type Approval Information 32
Cinterion® EHS6-A Hardware Interface Overview  Page 28 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 5  Regulatory and Type Approval Information 5.1  Directives and Standards EHS6-A is designed to comply with the directives and standards listed below. It is the responsibility of the application manufacturer to ensure compliance of the final product with  all  provisions  of  the  applicable  directives  and  standards  as  well  as  with  the  technical specifications provided in the "EHS6-A Hardware Interface Description".1 Table 5:  Directives 1999/05/EC Directive of the European Parliament and of the council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual  recognition  of  their  conformity  (in  short  referred  to  as  R&TTE Directive 1999/5/EC). The product is labeled with the CE conformity mark  2002/95/EC (RoHS 1) 2011/65/EC (RoHS 2) Directive of the European Parliament and of the Council of 27  January  2003  (and  revised  on  8  June  2011)  on  the restriction  of  the  use  of  certain  hazardous  substances  in electrical and electronic equipment (RoHS) Table 6:  Standards of North American type approval CFR Title 47 Code of Federal Regulations, Part 22 and Part 24 (Telecommunications, PCS); US Equipment Authorization FCC OET Bulletin 65 (Edition 97-01)  Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields UL 60 950-1 Product Safety Certification (Safety requirements) NAPRD.03 V5.15 Overview of PCS Type certification review board Mobile Equipment Type Certification and IMEI control PCS Type Certification Review board (PTCRB) RSS132 (Issue2) RSS133 (Issue5) Canadian StandardTable 7:  Standards of European type approval 3GPP TS 51.010-1 Digital cellular telecommunications system (Release 7); Mobile Station (MS) conformance specification; ETSI EN 301 511 V9.0.2 Global  System for Mobile communications (GSM); Harmonized standard for mobile stations in the GSM 900 and DCS 1800 bands covering essential requirements under article 3.2 of the R&TTE directive (1999/5/EC) GCF-CC V3.49 Global Certification Forum - Certification CriteriaETSI EN 301 489-01 V1.9.2 Electromagnetic  Compatibility  and  Radio  spectrum  Matters  (ERM); Electromagnetic  Compatibility  (EMC)  standard  for  radio  equipment  and services; Part 1: Common Technical Requirements                                                  1 .    Manufacturers  of  applications  which  can  be  used  in  the  US  shall  ensure  that  their  applications  have  a PTCRB approval. For this purpose they can refer to the PTCRB approval of the respective module.
Cinterion® EHS6-A Hardware Interface Overview  Page 29 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 5.1  Directives  and  Standards 32 Table 7:  Standards of European type approval ETSI EN 301 489-07 V1.3.1 Electromagnetic  Compatibility  and  Radio  spectrum  Matters  (ERM); Electromagnetic  Compatibility  (EMC)  standard  for  radio  equipment  and services;  Part  7:  Specific  conditions  for  mobile  and  portable  radio  and ancillary  equipment  of  digital  cellular  radio  telecommunications  systems (GSM and DCS) ETSI EN 301 489-24 V1.5.1 Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 24: Specific conditions for IMT-2000 CDMA Direct Spread (UTRA) for  Mobile and portable (UE) radio and ancillary equipment ETSI EN 301 908-01 V5.2.1 Electromagnetic  compatibility  and  Radio  spectrum  Matters  (ERM); Base Stations  (BS)  and  User  Equipment  (UE)  for  IMT-2000  Third  Generation cellular networks; Part 1: Harmonized EN for IMT-2000,  introduction  and common requirements of article 3.2 of the R&TTE Directive ETSI EN 301 908-02 V5.2.1 Electromagnetic  compatibility  and  Radio  spectrum  Matters  (ERM); Base Stations  (BS)  and  User  Equipment  (UE)  for  IMT-2000  Third  Generation cellular  networks;  Part  2:  Harmonized  EN  for  IMT-2000,  CDMA  Direct Spread (UTRA FDD) (UE) covering essential requirements of article 3.2 of the R&TTE Directive EN 62311:2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) IEC/EN 60950-1:2006/A1:2010+A12:2011 IEC 60950-1:2005/ A1:2009 (second edition) Safety of information technology equipmentTable 8:  Requirements of quality IEC 60068 Environmental testingDIN EN 60529 IP codes Table 9:  Standards of the Ministry of Information Industry of the People’s Republic of China SJ/T 11363-2006  “Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products” (2006-06). SJ/T 11364-2006 “Marking for Control of Pollution Caused by Electronic Information Products” (2006-06). According to the “Chinese Administration on the Control of Pollution caused by Electronic Information Products” (ACPEIP) the EPUP, i.e., Environmental Protection Use Period, of this product is 20 years as per the symbol shown here, unless otherwise  marked.  The  EPUP  is  valid  only  as  long  as  the  product is operated  within  the  operating  limits  described  in  the  Gemalto  M2M Hardware Interface Description. Please see Table 10 for an overview of toxic or hazardous substances or elements  that  might  be  contained  in  product  parts  in  concentrations above the limits defined by SJ/T 11363-2006.  5.1  Directives  and  Standards 32
Cinterion® EHS6-A Hardware Interface Overview Page 30 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary Table 10:  Toxic or hazardous substances or elements with defined concentration limits
Cinterion® EHS6-A Hardware Interface Overview  Page 31 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 5.2 SAR requirements specific to portable mobiles 32 5.2  SAR requirements specific to portable mobiles Mobile  phones,  PDAs  or  other  portable  transmitters  and  receivers  incorporating  a  GSM module  must  be  in  accordance with  the  guidelines  for  human  exposure  to  radio  frequency energy.  This  requires  the  Specific  Absorption  Rate  (SAR)  of  portable  EHS6-A  based applications to be evaluated and approved for compliance with national and/or international regulations.  Since the SAR value varies significantly with the individual product design manufacturers are advised to submit their product for approval if designed for portable use. For European and USmarkets  the  relevant  directives  are  mentioned  below.  It  is  the  responsibility  of  the manufacturer of the final product to verify whether or not further standards, recommendations or directives are in force outside these areas.  Products intended for sale on US markets ES 59005/ANSI C95.1 Considerations for evaluation of human exposure to Electromagnetic Fields (EMFs) from Mobile Telecommunication Equipment (MTE) in the frequency range 30MHz - 6GHz  Products intended for sale on European markets EN 50360 Product standard to demonstrate the compliance of mobile phones with the basic restrictions  related  to  human  exposure  to  electromagnetic  fields (300MHz - 3GHz) Please note that SAR requirements are specific only for portable devices and not for mobile devices as defined below: •  Portable device: A  portable  device  is  defined  as  a  transmitting  device  designed  to  be  used  so  that  the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. •  Mobile device: A mobile device is defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s) and the body of the user or nearby persons. In this context, the term ''fixed location'' means that the device is physically secured at one location and is not able to be easily moved to another location. 5.3 Reference Equipment for Type Approval 32 5.3  Reference Equipment for Type Approval The Gemalto M2M  reference  setup  submitted  to  type  approve  EHS6-A (including a special approval adapter for the DSB75) is shown in the following figure1:
Cinterion® EHS6-A Hardware Interface Overview Page 32 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary  1.  For RF performance tests a mini-SMT/U.FL to SMA adapter with attached 6dB coaxial attenuator is chosen to connect the evaluation module directly to the GSM/UMTS test equipment instead of employing the  SMA  antenna  connectors  on  the EHS6-A-DSB75  adapter  as  shown  in  Figure  9.  The  following products are recommended:  Hirose SMA-Jack/U.FL-Plug conversion adapter HRMJ-U.FLP(40) (for details see http://www.hirose-connectors.com/ or http://www.farnell.com/ Aeroflex Weinschel Fixed Coaxial Attenuator Model 3T/4T  (for details see http://www.aeroflex.com/ams/weinschel/pdfiles/wmod3&4T.pdf) 5.4 Compliance with FCC and IC Rules and Regulations 32 5.4  Compliance with FCC and IC Rules and Regulations The  Equipment  Authorization  Certification  for  the  Gemalto  M2M  reference  application described in Section 5.3 will be registered under the following identifiers:
Cinterion® EHS6-A Hardware Interface Overview  Page 33 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary FCC Identifier: QIPEHS6-A Industry Canada Certification Number: 7830A-EHS6A Granted to Gemalto M2M GmbH  Manufacturers of mobile or fixed devices incorporating EHS6-A modules are authorized to use the FCC Grants and Industry Canada Certificates of the EHS6-A modules for their own final products according to the conditions referenced in these documents. In this case, an FCC/ IC label of the module shall be visible from the outside, or the host device shall bear a second label stating "Contains FCC ID QIPEHS6-A", and accordingly “Contains IC 7830A-EHS6A“. The  integration  is  limited  to  fixed  or  mobile  categorised  host  devices,  where  a  separation distance between the antenna and any person of min. 20cm can be assured during normal operating conditions. For mobile and fixed operation configurations the antenna gain, including cable loss, must not exceed the limits 2.15 dBi (850 MHz) and 2.15 dBi (1900 MHz). IMPORTANT:  Manufacturers of portable applications incorporating EHS6-A modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable mobile. This is mandatory to meet the SAR requirements for portable mobiles (see Section 5.2 for detail). Changes  or  modifications  not  expressly  approved  by  the  party  responsible  for  compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s).  These  limits  are  designed  to  provide  reasonable  protection  against  harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful  interference  to  radio  communications.  However,  there  is  no  guarantee  that interference  will  not  occur  in  a  particular  installation.  If  this  equipment  does  cause  harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the  user  is encouraged  to  try  to  correct the  interference  by one  or more  of  the following measures:  •  Reorient or relocate the receiving antenna. •  Increase the separation between the equipment and receiver. •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •  Consult the dealer or an experienced radio/TV technician for help. This Class B digital apparatus complies with Canadian ICES-003. If Canadian approval is requested for devices incorporating EHS6-A modules the above note will have to be provided in the English and French language in the final user documentation. Manufacturers/OEM Integrators must ensure that the final user documentation does not contain any information on how to install or remove the module from the final product. 6  Document  Information 37
Cinterion® EHS6-A Hardware Interface Overview  Page 34 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 6  Document Information 6.1  Revision History New document: "Cinterion® EHS6-A Hardware Interface Overview" Version 02.770 Chapter What is new -- Initial document setup. 6.2  Related Documents [1]  EHS6-A AT Command Set [2]  EHS6-A Release Note [3]  Application Note 48: SMT Module Integration [4]  Application Note 40: Thermal Solutions [5]  Universal Serial Bus Specification Revision 2.0, April 27, 2000 6.3  Terms and Abbreviations Abbreviation Description ADC Analog-to-digital converterAGC Automatic Gain ControlANSI American National Standards InstituteARFCN Absolute Radio Frequency Channel NumberARP Antenna Reference PointASC0/ASC1 Asynchronous Controller. Abbreviations used for first and second serial interface of EHS6-A B Thermistor Constant BER Bit Error Rate BTS Base Transceiver StationCB or CBM Cell Broadcast MessageCE Conformité Européene (European Conformity)CHAP Challenge Handshake Authentication ProtocolCPU Central Processing UnitCS Coding Scheme CSD Circuit Switched Data CTS Clear to Send
Cinterion® EHS6-A Hardware Interface Overview  Page 35 of 41 6.3 Terms and Abbreviations 37 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary  Abbreviation Description DAC Digital-to-Analog ConverterDAI Digital Audio InterfacedBm0 Digital level, 3.14dBm0 corresponds to full scale, see ITU G.711, A-law DCE Data Communication Equipment (typically modems, e.g. Gemalto M2M module)DCS 1800 Digital Cellular System, also referred to as PCNDRX Discontinuous ReceptionDSB Development Support BoxDSP Digital Signal ProcessorDSR Data Set Ready DTE Data Terminal Equipment (typically computer, terminal, printer or, for example, GSM application) DTR Data Terminal Ready DTX Discontinuous TransmissionEFR Enhanced Full Rate EGSM Enhanced GSM EIRP Equivalent Isotropic Radiated PowerEMC Electromagnetic CompatibilityERP Effective Radiated PowerESD Electrostatic DischargeETS European Telecommunication StandardFCC Federal Communications Commission (U.S.)FDMA Frequency Division Multiple AccessFR Full Rate GMSK Gaussian Minimum Shift KeyingGPIO General Purpose Input/OutputGPRS General Packet Radio ServiceGSM Global Standard for Mobile CommunicationsHiZ High Impedance HR Half Rate I/O Input/Output IC Integrated Circuit IMEI International Mobile Equipment IdentityISO International Standards Organization
Cinterion® EHS6-A Hardware Interface Overview  Page 36 of 41 6.3 Terms and Abbreviations 37 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary ITU International Telecommunications Unionkbps kbits per second LED Light Emitting Diode Li-Ion/Li+ Lithium-Ion Li battery Rechargeable Lithium Ion or Lithium Polymer battery Abbreviation Description LPM Link Power ManagementMbps Mbits per second MMI Man Machine InterfaceMO Mobile Originated MS Mobile Station (GSM module), also referred to as TEMSISDN Mobile Station International ISDN numberMT Mobile Terminated NTC Negative Temperature CoefficientOEM Original Equipment ManufacturerPA Power Amplifier PAP Password Authentication ProtocolPBCCH Packet Switched Broadcast Control ChannelPCB Printed Circuit Board PCL Power Control Level PCM Pulse Code ModulationPCN Personal Communications Network, also referred to as DCS 1800 PCS Personal Communication System, also referred to as GSM 1900 PDU Protocol Data Unit PLL Phase Locked Loop PPP Point-to-point protocolPSK Phase Shift Keying PSU Power Supply Unit PWM Pulse Width ModulationR&TTE Radio and Telecommunication Terminal EquipmentRAM Random Access MemoryRF Radio Frequency RLS Radio Link Stability RMS Root Mean Square (value)
Cinterion® EHS6-A Hardware Interface Overview  Page 37 of 41 6.3 Terms and Abbreviations 37 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary RoHS Restriction of the use of certain hazardous substances in electrical and electronic equipment.  ROM Read-only Memory RTC Real Time Clock RTS Request to Send Rx Receive Direction SAR Specific Absorption RateSAW Surface Accoustic WaveSELV Safety Extra Low VoltageSIM Subscriber Identification Module Abbreviation Description SMD Surface Mount DeviceSMS Short Message ServiceSMT Surface Mount TechnologySPI Serial Peripheral InterfaceSRAM Static Random Access MemoryTA Terminal adapter (e.g. GSM module)TDMA Time Division Multiple AccessTE Terminal Equipment, also referred to as DTETLS Transport Layer SecurityTx Transmit Direction UART Universal asynchronous receiver-transmitterURC Unsolicited Result CodeUSSD Unstructured Supplementary Service DataVSWR Voltage Standing Wave Ratio
Cinterion® EHS6-A Hardware Interface Overview Page 38 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 6.4  Safety  Precaution  Notes 37 6.4  Safety Precaution Notes The following safety precautions must be observed during all phases of the operation, usage, service or repair of any cellular terminal or mobile incorporating EHS6-A. Manufacturers of the cellular terminal are advised to convey the following safety information to users and operating personnel and to incorporate these guidelines into all manuals supplied with the product. Failure to comply with these precautions violates safety standards of design, manufacture and intended use of the product. Gemalto M2M assumes no liability for customer’s failure to comply with these precautions.  When in a hospital or other health care facility, observe the restrictions on the use of mobiles.  Switch  the  cellular  terminal  or  mobile  off,  if  instructed  to  do  so  by  the guidelines  posted  in  sensitive  areas.  Medical  equipment  may  be  sensitive  to  RF energy. The operation of cardiac pacemakers, other implanted medical equipment and hearing aids can be affected by interference from cellular terminals or mobiles placed close to the device. If in doubt about potential danger, contact the physician or the manufacturer  of  the  device  to  verify  that  the  equipment  is  properly  shielded. Pacemaker  patients  are  advised  to  keep  their  hand-held  mobile  away  from  the pacemaker, while it is on.   Switch  off  the  cellular  terminal  or  mobile  before  boarding  an  aircraft.  Make  sure  it cannot  be  switched  on  inadvertently.  The  operation  of  wireless  appliances  in  an aircraft is forbidden to prevent interference with communications systems. Failure to observe these instructions may lead to the suspension or denial of cellular services to the offender, legal action, or both.  Do not operate the cellular terminal or mobile in the presence of flammable gases or fumes. Switch off the cellular terminal when you are near petrol stations, fuel depots, chemical  plants  or  where  blasting  operations  are  in  progress.  Operation  of  any electrical  equipment  in  potentially  explosive  atmospheres  can  constitute  a  safety hazard.  Your cellular terminal or mobile receives and transmits radio frequency energy while switched on. Remember that interference can  occur  if  it  is  used close to TV sets, radios,  computers  or  inadequately  shielded  equipment.  Follow  any  special regulations and always switch off the cellular terminal or mobile wherever forbidden, or when you suspect that it may cause interference or danger.  Road  safety  comes  first!  Do  not  use  a  hand-held  cellular  terminal  or  mobile  when driving a vehicle, unless it is securely mounted in a holder for speakerphone operation. Before making a call with a hand-held terminal or mobile, park the vehicle.  Speakerphones must be installed by qualified personnel. Faulty installation or operation can constitute a safety hazard.  IMPORTANT! Cellular terminals or mobiles operate using radio signals and cellular networks.  Because of this, connection cannot be guaranteed at all times under all conditions. Therefore, you should never rely solely upon any wireless device for essential communications, for example emergency calls.  Remember, in order to make or receive calls, the cellular terminal or mobile must be switched on and in a service area with adequate cellular signal strength.  Some networks do not allow for emergency calls if certain network services or phone features are in use (e.g. lock functions, fixed dialing etc.). You may need to deactivate those features before you can make an emergency call. Some  networks  require  that  a  valid  SIM  card  be  properly  inserted  in  the  cellular terminal or mobile.
Cinterion® EHS6-A Hardware Interface Overview  Page 39 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary 7  Appendix 39 7  Appendix 7.1  List of Parts and Accessories Table 11:  List of parts and accessories Description Supplier Ordering informationEHS6-A Gemalto M2M Standard module Gemalto M2M IMEI: Packaging unit (ordering) number: L30960-N2960-A300 Module label number: S30960-S2960-A300-1 Customer IMEI mode: Packaging unit (ordering) number: L30960-N2965-A300Module label number: S30960-S2965-A300-1 DSB75 Evaluation Kit Gemalto M2M Ordering number: L36880-N8811-A100 Multi-Adapter  R1  for mounting  EHS6-A evaluation  modules  onto DSB75 Gemalto M2M Ordering number: L30960-N0010-A100 Approval  adapter  for mounting  EHS6-A evaluation  modules  onto DSB75 Gemalto M2M Ordering number: L30960-N2301-A100 Evaluation Module Gemalto M2M Ordering number: L30960-N2961-A300 (EHS6-A)Votronic Handset Votronic / Gemalto M2MGemalto M2M ordering number: L36880-N8301-A107Votronic ordering number: HH-SI-30.3/V1.1/0 Votronic  Entwicklungs- und Produktionsgesellschaft für elektronische Geräte mbH Saarbrücker Str. 8 66386 St. Ingbert Germany Phone:  +49-(0)6 89 4 / 92 55-0 Fax:  +49-(0)6 89 4 / 92 55-88 Email:  contact@votronic.com SIM card holder incl. push button ejector and slide-in tray Molex Ordering numbers: 91228 91236 Sales contacts are listed in Table 12. 7.1 List of Parts and Accessories 39 Table 12:  Molex sales contacts (subject to change)
Cinterion® EHS6-A Hardware Interface Overview  Page 40 of 41 EHS6-A_HIO_v02.770  2014-08-13 Confidential / Preliminary Molex For further information please click: http://www.molex.com Molex Deutschland GmbHOtto-Hahn-Str. 1b 69190 Walldorf Germany Phone: +49-6227-3091-0 Fax: +49-6227-3091-8100 Email:  mxgermany@molex.comAmerican HeadquartersLisle, Illinois 60532 U.S.A. Phone: +1-800-78MOLEXFax: +1-630-969-1352 Molex China DistributorsBeijing,  Room 1311, Tower B, COFCO Plaza No. 8, Jian Guo Men Nei Street, 100005Beijing P.R. China Phone:  +86-10-6526-9628  Fax:  +86-10-6526-9730 Molex Singapore Pte. Ltd.110, International Road Jurong Town,  Singapore 629174 Phone:  +65-6-268-6868 Fax: +65-6-265-6044 Molex Japan Co. Ltd.1-5-4 Fukami-Higashi, Yamato-City, Kanagawa, 242-8585 Japan Phone:  +81-46-265-2325Fax: +81-46-265-2365
   40    M2M.GEMALTO.COM About Gemalto Gemalto (Euronext NL0000400653 GTO) is the world leader in digital security with 2011 annual revenues of €2 billion and more than 10,000 employees operating out of 74 offices and 14 Research & Development centers, located in 43 countries.We are at the heart of the rapidly evolving digital society. Billions of people worldwide increasingly want the freedom to communicate, travel, shop, bank, entertain and work - anytime, everywhere  -  in ways that are enjoyable and safe. Gemalto delivers on their expanding needs for personal mobile services, payment security, authenticated cloud access, identity and privacy protection, eHealthcare and eGovernment efficiency, convenient ticketing and dependable machine-to- machine (M2M) applications. Gemalto develops secure embedded software and secure products which we design and  personalize. Our platforms and services manage these secure products, the confidential data they  contain and the trusted end-user services they enable. Our inovations enable our clients to offer trusted and convenient digital services to billions of individuals.Gemalto thrives with the growing number of people using its solutions to interact with the digital and wireless world. For more information please visit m2m.gemalto.com, www.facebook.com/gemalto, or Follow@gemaltom2m on twitter. Gemalto M2M GmbH St.-Martin-Str. 60 81541  Munich Germany

Navigation menu