THALES DIS AlS Deutschland PHS8-P GSM/GPRS/UMTS/HSPA Module User Manual hio

Gemalto M2M GmbH GSM/GPRS/UMTS/HSPA Module hio

Contents

User Manual

PHS8-P
Version: 01.000
DocId: PHS8-P_HIO_v01.000
Hardware Interface Overview
GENERAL NOTE
THE USE OF THE PRODUCT INCLUDING THE SOFTWARE AND DOCUMENTATION (THE "PROD-
UCT") IS SUBJECT TO THE RELEASE NOTE PROVIDED TOGETHER WITH PRODUCT. IN ANY
EVENT THE PROVISIONS OF THE RELEASE NOTE SHALL PREVAIL. THIS DOCUMENT CON-
TAINS INFORMATION ON CINTERION PRODUCTS. THE SPECIFICATIONS IN THIS DOCUMENT
ARE SUBJECT TO CHANGE AT CINTERION'S DISCRETION. CINTERION WIRELESS MODULES
GMBH GRANTS A NON-EXCLUSIVE RIGHT TO USE THE PRODUCT. THE RECIPIENT SHALL NOT
TRANSFER, COPY, MODIFY, TRANSLATE, REVERSE ENGINEER, CREATE DERIVATIVE WORKS;
DISASSEMBLE OR DECOMPILE THE PRODUCT OR OTHERWISE USE THE PRODUCT EXCEPT
AS SPECIFICALLY AUTHORIZED. THE PRODUCT AND THIS DOCUMENT ARE PROVIDED ON AN
"AS IS" BASIS ONLY AND MAY CONTAIN DEFICIENCIES OR INADEQUACIES. TO THE MAXIMUM
EXTENT PERMITTED BY APPLICABLE LAW, CINTERION WIRELESS MODULES GMBH DIS-
CLAIMS ALL WARRANTIES AND LIABILITIES. THE RECIPIENT UNDERTAKES FOR AN UNLIMITED
PERIOD OF TIME TO OBSERVE SECRECY REGARDING ANY INFORMATION AND DATA PRO-
VIDED TO HIM IN THE CONTEXT OF THE DELIVERY OF THE PRODUCT. THIS GENERAL NOTE
SHALL BE GOVERNED AND CONSTRUED ACCORDING TO GERMAN LAW.
Copyright
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its con-
tents and communication thereof to others without express authorization are prohibited. Offenders will
be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Copyright © 2011, Cinterion Wireless Modules GmbH
Trademark Notice
Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the
United States and/or other countries. All other registered trademarks or trademarks mentioned in this
document are property of their respective owners.
PHS8-P_HIO_v01.000 Page 2 of 41 2011-11-10
Confidential / Released
PHS8-P Hardware Interface Overview
2
Document Name: PHS8-P Hardware Interface Overview
Version: 01.000
Date: 2011-11-10
DocId: PHS8-P_HIO_v01.000
Status Confidential / Released
PHS8-P Hardware Interface Overview
Contents
41
PHS8-P_HIO_v01.000 Page 3 of 41 2011-11-10
Confidential / Released
Contents
1 Introduction ................................................................................................................. 6
1.1 Related Documents ........................................................................................... 6
1.2 Terms and Abbreviations ................................................................................... 6
1.3 Regulatory and Type Approval Information ..................................................... 10
1.3.1 Directives and Standards.................................................................... 10
1.3.2 SAR requirements specific to portable mobiles .................................. 13
1.3.3 SELV Requirements ........................................................................... 14
1.3.4 Safety Precautions.............................................................................. 14
2 Product Concept ....................................................................................................... 16
2.1 Key Features at a Glance ................................................................................ 16
2.2 PHS8-P System Overview ............................................................................... 19
3 Application Interface................................................................................................. 20
3.1 Operating Modes ............................................................................................. 21
3.2 Power Supply................................................................................................... 22
3.3 USB Interface................................................................................................... 23
3.4 Serial Interface ASC0 ...................................................................................... 24
3.5 UICC/SIM/USIM Interface................................................................................ 26
3.6 Analog Audio Interface..................................................................................... 28
3.7 Digital Audio Interface...................................................................................... 28
4 GPS Receiver............................................................................................................. 29
5 Antenna Interfaces.................................................................................................... 30
5.1 GSM/UMTS Antenna Interface ........................................................................ 30
5.1.1 Antenna Installation ............................................................................ 31
5.2 GPS Antenna Interface .................................................................................... 32
6 Mechanics.................................................................................................................. 34
6.1 Mechanical Dimensions of PHS8-P ................................................................. 34
7 Sample Application................................................................................................... 36
8 Reference Approval .................................................................................................. 38
8.1 Reference Equipment for Type Approval......................................................... 38
8.2 Compliance with FCC and IC Rules and Regulations ..................................... 39
9 Appendix.................................................................................................................... 40
9.1 List of Parts and Accessories........................................................................... 40
PHS8-P Hardware Interface Overview
Tab le s
41
PHS8-P_HIO_v01.000 Page 4 of 41 2011-11-10
Confidential / Released
Tables
Table 1: Directives ....................................................................................................... 10
Table 2: Standards of North American type approval .................................................. 10
Table 3: Standards of European type approval............................................................ 10
Table 4: Requirements of quality ................................................................................. 11
Table 5: Standards of the Ministry of Information Industry of the
People’s Republic of China............................................................................ 11
Table 6: Toxic or hazardous substances or elements with defined concentration
limits............................................................................................................... 12
Table 7: Overview of operating modes ........................................................................ 21
Table 8: DCE-DTE wiring of ASC0 .............................................................................. 25
Table 9: Signals of the SIM interface (SMT application interface) ............................... 26
Table 10: Return loss in the active band........................................................................ 30
Table 11: List of parts and accessories.......................................................................... 40
Table 12: Molex sales contacts (subject to change) ...................................................... 41
Table 13: Hirose sales contacts (subject to change) ..................................................... 41
PHS8-P Hardware Interface Overview
Figures
41
PHS8-P_HIO_v01.000 Page 5 of 41 2011-11-10
Confidential / Released
Figures
Figure 1: PHS8-P system overview............................................................................... 19
Figure 2: Decoupling capacitor(s) for BATT+................................................................ 22
Figure 3: USB circuit ..................................................................................................... 23
Figure 4: Serial interface ASC0..................................................................................... 24
Figure 5: UICC/SIM/USIM interface .............................................................................. 27
Figure 6: Supply voltage for active GPS antenna ......................................................... 32
Figure 7: ESD protection for passive GPS antenna...................................................... 33
Figure 8: PHS8-P – top view......................................................................................... 34
Figure 9: Dimensions of PHS8-P (all dimensions in mm) ............................................. 35
Figure 10: PHS8-P sample application ........................................................................... 37
Figure 11: Reference equipment for type approval......................................................... 38
PHS8-P Hardware Interface Overview
1 Introduction
15
PHS8-P_HIO_v01.000 Page 6 of 111 2011-11-10
Confidential / Released
1 Introduction
The document1 describes the hardware of the PHS8-P module, designed to connect to a cel-
lular device application and the air interface. It helps you quickly retrieve interface specifica-
tions, electrical and mechanical details and information on the requirements to be considered
for integrating further components.
1.1 Related Documents
[1] PHS8-P AT Command Set
[2] PHS8-P Release Notes
[3] DSB75 Support Box - Evaluation Kit for Cinterion Wireless Modules
[4] Application Note 48: SMT Module Integration
1.2 Terms and Abbreviations
1. The document is effective only if listed in the appropriate Release Notes as part of the technical
documentation delivered with your Cinterion Wireless Modules product.
Abbreviation Description
AGPS Assisted GPS
ANSI American National Standards Institute
AMR Adaptive Multirate
ARP Antenna Reference Point
BB Baseband
BEP Bit Error Probability
BTS Base Transceiver Station
CB or CBM Cell Broadcast Message
CE Conformité Européene (European Conformity)
CS Coding Scheme
CS Circuit Switched
CSD Circuit Switched Data
CTM Cellular Text Modem
DAC Digital-to-Analog Converter
DCS Digital Cellular System
DL Download
DRX Discontinuous Reception
DSB Development Support Board
PHS8-P Hardware Interface Overview
1.2 Terms and Abbreviations
15
PHS8-P_HIO_v01.000 Page 7 of 111 2011-11-10
Confidential / Released
DSP Digital Signal Processor
DTMF Dual Tone Multi Frequency
DTX Discontinuous Transmission
EDGE Enhanced Data rates for GSM Evolution
EFR Enhanced Full Rate
EGSM Extended GSM
EMC Electromagnetic Compatibility
ERP Effective Radiated Power
ESD Electrostatic Discharge
ETS European Telecommunication Standard
ETSI European Telecommunications Standards Institute
FCC Federal Communications Commission (U.S.)
FDD Frequency Division Duplex
FDMA Frequency Division Multiple Access
FR Full Rate
GPRS General Packet Radio Service
GPS Global Positioning System
GSM Global Standard for Mobile Communications
HiZ High Impedance
HSDPA High Speed Downlink Packet Access
HR Half Rate
I/O Input/Output
IF Intermediate Frequency
IMEI International Mobile Equipment Identity
ISO International Standards Organization
ITU International Telecommunications Union
kbps kbits per second
LED Light Emitting Diode
LGA Land Grid Array
MBB Moisture barrier bag
Mbps Mbits per second
MCS Modulation and Coding Scheme
MO Mobile Originated
MS Mobile Station, also referred to as TE
MSL Moisture Sensitivity Level
MT Mobile Terminated
Abbreviation Description
PHS8-P Hardware Interface Overview
1.2 Terms and Abbreviations
15
PHS8-P_HIO_v01.000 Page 8 of 111 2011-11-10
Confidential / Released
NMEA National Marine Electronics Association
NTC Negative Temperature Coefficient
PBCCH Packet Switched Broadcast Control Channel
PCB Printed Circuit Board
PCL Power Control Level
PCM Pulse Code Modulation
PCS Personal Communication System, also referred to as GSM 1900
PD Pull Down resistor (appr. 100k)
PDU Protocol Data Unit
PS Packet Switched
PSK Phase Shift Keying
PU Pull Up resistor (appr. 100k)
QAM Quadrature Amplitude Modulation
R&TTE Radio and Telecommunication Terminal Equipment
RF Radio Frequency
ROPR Radio Output Power Reduction
RTC Real Time Clock
Rx Receive Direction
SAR Specific Absorption Rate
SELV Safety Extra Low Voltage
SIM Subscriber Identification Module
SLIC Subscriber Line Interface Circuit
SMPL Sudden Momentary Power Loss
SMD Surface Mount Device
SMS Short Message Service
SMT Surface Mount Technology
SNR Signal-to-Noise Ratio
SRAM Static Random Access Memory
SRB Signalling Radio Bearer
SUPL Secure User Plane Location
TDMA Time Division Multiple Access
TE Terminal Equipment
TPC Transmit Power Control
TS Technical Specification
TTFF Time To First Fix
Tx Transmit Direction
Abbreviation Description
PHS8-P Hardware Interface Overview
1.2 Terms and Abbreviations
15
PHS8-P_HIO_v01.000 Page 9 of 111 2011-11-10
Confidential / Released
UL Upload
UMTS Universal Mobile Telecommunications System
URC Unsolicited Result Code
USB Universal Serial Bus
UICC USIM Integrated Circuit Card
USIM UMTS Subscriber Identification Module
WCDMA Wideband Code Division Multiple Access
Abbreviation Description
PHS8-P Hardware Interface Overview
1.3 Regulatory and Type Approval Information
15
PHS8-P_HIO_v01.000 Page 10 of 111 2011-11-10
Confidential / Released
1.3 Regulatory and Type Approval Information
1.3.1 Directives and Standards
PHS8-P has been designed to comply with the directives and standards listed below.
It is the responsibility of the application manufacturer to ensure compliance of the final product
with all provisions of the applicable directives and standards as well as with the technical spec-
ifications provided in the "PHS8-P Hardware Interface Description".1
1. Manufacturers of applications which can be used in the US shall ensure that their applications have a
PTCRB approval. For this purpose they can refer to the PTCRB approval of the respective module.
Table 1: Directives
99/05/EC Directive of the European Parliament and of the council of 9 March 1999 on
radio equipment and telecommunications terminal equipment and the
mutual recognition of their conformity (in short referred to as R&TTE Direc-
tive 1999/5/EC).
The product is labeled with the CE conformity mark
2002/95/EC Directive of the European Parliament and of the Council of
27 January 2003 on the restriction of the use of certain haz-
ardous substances in electrical and electronic equipment
(RoHS)
Table 2: Standards of North American type approval
CFR Title 47 Code of Federal Regulations, Part 22, Part 24 and Part 27; US Equipment
Authorization FCC
OET Bulletin 65
(Edition 97-01)
Evaluating Compliance with FCC Guidelines for Human Exposure to Radio-
frequency Electromagnetic Fields
UL 60 950-1 Product Safety Certification (Safety requirements)
NAPRD.03 V5.8 Overview of PCS Type certification review board Mobile Equipment Type
Certification and IMEI control
PCS Type Certification Review board (PTCRB)
RSS132, RSS133,
RSS139
Canadian Standard
Table 3: Standards of European type approval
3GPP TS 51.010-1 Digital cellular telecommunications system (Release 7); Mobile Station
(MS) conformance specification;
ETSI EN 301 511 V9.0.2 Global System for Mobile communications (GSM); Harmonized standard for
mobile stations in the GSM 900 and DCS 1800 bands covering essential
requirements under article 3.2 of the R&TTE directive (1999/5/EC)
GCF-CC V3.43.1 Global Certification Forum - Certification Criteria
ETSI EN 301 489-01
V1.8.1
Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electro-
magnetic Compatibility (EMC) standard for radio equipment and services;
Part 1: Common Technical Requirements
PHS8-P Hardware Interface Overview
1.3 Regulatory and Type Approval Information
15
PHS8-P_HIO_v01.000 Page 11 of 111 2011-11-10
Confidential / Released
ETSI EN 301 489-03
V1.4.1
Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electro-
magnetic Compatibility (EMC) standard for radio equipment and services;
Part 3: Specific conditions for Short-Range Devices (SRD) operating on fre-
quencies between 9 kHz and 40 GHz
ETSI EN 301 489-07
V1.3.1
Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electro-
magnetic Compatibility (EMC) standard for radio equipment and services;
Part 7: Specific conditions for mobile and portable radio and ancillary equip-
ment of digital cellular radio telecommunications systems (GSM and DCS)
ETSI EN 301 489-24
V1.4.1
Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electro-
magnetic Compatibility (EMC) standard for radio equipment and services;
Part 24: Specific conditions for IMT-2000 CDMA Direct Spread (UTRA) for
Mobile and portable (UE) radio and ancillary equipment
EN 301 908-01 V3.2.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); Base
Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation cel-
lular networks; Part 1: Harmonized EN for IMT-2000, introduction and com-
mon requirements of article 3.2 of the R&TTE Directive
EN 301 908-02 V3.2.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); Base
Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation cel-
lular networks; Part 2: Harmonized EN for IMT-2000, CDMA Direct Spread
(UTRA FDD) (UE) covering essential requirements of article 3.2 of the
R&TTE Directive
EN 300 440-02 V1.3.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); Short
range devices; Radio equipment to be used in the 1 GHz to 40 GHz fre-
quency range; Part 2: Harmonized EN covering essential requirements of
article 3.2 of the R&TTE Directive
EN 62311:2008 Assessment of electronic and electrical equipment related to human expo-
sure restrictions for electromagnetic fields (0 Hz - 300 GHz)
IEC/EN 60950-1:2006 Safety of information technology equipment
Table 4: Requirements of quality
IEC 60068 Environmental testing
DIN EN 60529 IP codes
Table 5: Standards of the Ministry of Information Industry of the People’s Republic of China
SJ/T 11363-2006 “Requirements for Concentration Limits for Certain Hazardous Substances
in Electronic Information Products” (2006-06).
SJ/T 11364-2006 “Marking for Control of Pollution Caused by Electronic
Information Products” (2006-06).
According to the “Chinese Administration on the Control of
Pollution caused by Electronic Information Products”
(ACPEIP) the EPUP, i.e., Environmental Protection Use
Period, of this product is 20 years as per the symbol
shown here, unless otherwise marked. The EPUP is valid only as long as
the product is operated within the operating limits described in the Cinterion
Hardware Interface Description.
Please see Table 6 for an overview of toxic or hazardous substances or ele-
ments that might be contained in product parts in concentrations above the
limits defined by SJ/T 11363-2006.
Table 3: Standards of European type approval
PHS8-P Hardware Interface Overview
1.3 Regulatory and Type Approval Information
15
PHS8-P_HIO_v01.000 Page 12 of 111 2011-11-10
Confidential / Released
Table 6: Toxic or hazardous substances or elements with defined concentration limits
PHS8-P Hardware Interface Overview
1.3 Regulatory and Type Approval Information
15
PHS8-P_HIO_v01.000 Page 13 of 111 2011-11-10
Confidential / Released
1.3.2 SAR requirements specific to portable mobiles
Mobile phones, PDAs or other portable transmitters and receivers incorporating a GSM module
must be in accordance with the guidelines for human exposure to radio frequency energy. This
requires the Specific Absorption Rate (SAR) of portable PHS8-P based applications to be eval-
uated and approved for compliance with national and/or international regulations.
Since the SAR value varies significantly with the individual product design manufacturers are
advised to submit their product for approval if designed for portable use. For European and US-
markets the relevant directives are mentioned below. It is the responsibility of the manufacturer
of the final product to verify whether or not further standards, recommendations or directives
are in force outside these areas.
Products intended for sale on US markets
ES 59005/ANSI C95.1 Considerations for evaluation of human exposure to electromagnetic
fields (EMFs) from mobile telecommunication equipment (MTE) in the
frequency range 30MHz - 6GHz
Products intended for sale on European markets
EN 50360 Product standard to demonstrate the compliance of mobile phones with
the basic restrictions related to human exposure to electromagnetic
fields (300MHz - 3GHz)
IMPORTANT:
Manufacturers of portable applications based on PHS8-P modules are required to have their
final product certified and apply for their own FCC Grant and Industry Canada Certificate relat-
ed to the specific portable mobile.
PHS8-P Hardware Interface Overview
1.3 Regulatory and Type Approval Information
15
PHS8-P_HIO_v01.000 Page 14 of 111 2011-11-10
Confidential / Released
1.3.3 SELV Requirements
The power supply connected to the PHS8-P module shall be in compliance with the SELV re-
quirements defined in EN 60950-1.
1.3.4 Safety Precautions
The following safety precautions must be observed during all phases of the operation, usage,
service or repair of any cellular terminal or mobile incorporating PHS8-P. Manufacturers of the
cellular terminal are advised to convey the following safety information to users and operating
personnel and to incorporate these guidelines into all manuals supplied with the product. Fail-
ure to comply with these precautions violates safety standards of design, manufacture and in-
tended use of the product. Cinterion Wireless Modules assumes no liability for customer’s
failure to comply with these precautions.
When in a hospital or other health care facility, observe the restrictions on the use of
mobiles. Switch the cellular terminal or mobile off, if instructed to do so by the guide-
lines posted in sensitive areas. Medical equipment may be sensitive to RF energy.
The operation of cardiac pacemakers, other implanted medical equipment and hearing
aids can be affected by interference from cellular terminals or mobiles placed close to
the device. If in doubt about potential danger, contact the physician or the manufac-
turer of the device to verify that the equipment is properly shielded. Pacemaker
patients are advised to keep their hand-held mobile away from the pacemaker, while
it is on.
Switch off the cellular terminal or mobile before boarding an aircraft. Make sure it can-
not be switched on inadvertently. The operation of wireless appliances in an aircraft is
forbidden to prevent interference with communications systems. Failure to observe
these instructions may lead to the suspension or denial of cellular services to the
offender, legal action, or both.
Do not operate the cellular terminal or mobile in the presence of flammable gases or
fumes. Switch off the cellular terminal when you are near petrol stations, fuel depots,
chemical plants or where blasting operations are in progress. Operation of any electri-
cal equipment in potentially explosive atmospheres can constitute a safety hazard.
Your cellular terminal or mobile receives and transmits radio frequency energy while
switched on. Remember that interference can occur if it is used close to TV sets,
radios, computers or inadequately shielded equipment. Follow any special regulations
and always switch off the cellular terminal or mobile wherever forbidden, or when you
suspect that it may cause interference or danger.
Road safety comes first! Do not use a hand-held cellular terminal or mobile when driv-
ing a vehicle, unless it is securely mounted in a holder for speakerphone operation.
Before making a call with a hand-held terminal or mobile, park the vehicle.
Speakerphones must be installed by qualified personnel. Faulty installation or opera-
tion can constitute a safety hazard.
PHS8-P Hardware Interface Overview
1.3 Regulatory and Type Approval Information
15
PHS8-P_HIO_v01.000 Page 15 of 111 2011-11-10
Confidential / Released
IMPORTANT!
Cellular terminals or mobiles operate using radio signals and cellular networks.
Because of this, connection cannot be guaranteed at all times under all conditions.
Therefore, you should never rely solely upon any wireless device for essential com-
munications, for example emergency calls.
Remember, in order to make or receive calls, the cellular terminal or mobile must be
switched on and in a service area with adequate cellular signal strength.
Some networks do not allow for emergency calls if certain network services or phone
features are in use (e.g. lock functions, fixed dialing etc.). You may need to deactivate
those features before you can make an emergency call.
Some networks require that a valid SIM card be properly inserted in the cellular termi-
nal or mobile.
Bear in mind that exposure to excessive levels of noise can cause physical damage
to users! With regard to acoustic shock, the cellular application must be designed to
avoid unintentional increase of amplification, e.g. for a highly sensitive earpiece. A pro-
tection circuit should be implemented in the cellular application.
PHS8-P Hardware Interface Overview
2 Product Concept
19
PHS8-P_HIO_v01.000 Page 16 of 41 2011-11-10
Confidential / Released
2 Product Concept
2.1 Key Features at a Glance
Feature Implementation
General
Frequency bands GSM/GPRS/EDGE: Quad band, 850/900/1800/1900MHz
UMTS/HSPA+: Five band, 800/850/9001/1900/2100MHz
GSM class Small MS
Output power (according to
Release 99)
Class 4 (+33dBm ±2dB) for EGSM850
Class 4 (+33dBm ±2dB) for EGSM900
Class 1 (+30dBm ±2dB) for GSM1800
Class 1 (+30dBm ±2dB) for GSM1900
Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK
Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK
Class 3 (+24dBm +1/-3dB) for UMTS 2100, WCDMA FDD BdI
Class 3 (+24dBm +1/-3dB) for UMTS 1900,WCDMA FDD BdII
Class 3 (+24dBm +1/-3dB) for UMTS 900, WCDMA FDD BdVIII
Class 3 (+24dBm +1/-3dB) for UMTS 850, WCDMA FDD BdV
Class 3 (+24dBm +1/-3dB) for UMTS 800, WCDMA FDD BdVI
Power supply 3.3V < VBATT+ < 4.2V
Operating temperature
(board temperature)
Normal operation: -30°C to +85°C
Restricted operation: -40°C to +95°C
Physical Dimensions: 33mm x 29mm x 2mm
Weight: approx. 5g
RoHS All hardware components fully compliant with EU RoHS Directive
HSPA features
3GPP Release 6, 7 DL 14.4Mbps, UL 5.7Mbps
UE CAT. 1-12 supported
Compressed mode (CM) supported according to 3GPP TS25.212
UMTS features
3GPP Release 4 PS data rate – 384 kbps DL / 384 kbps UL
CS data rate – 64 kbps DL / 64 kbps UL
PHS8-P Hardware Interface Overview
2.1 Key Features at a Glance
19
PHS8-P_HIO_v01.000 Page 17 of 41 2011-11-10
Confidential / Released
GSM / GPRS / EGPRS features
Data transfer GPRS:
Multislot Class 12
Full PBCCH support
Mobile Station Class B
Coding Scheme 1 – 4
EGPRS:
Multislot Class 12
EDGE E2 power class for 8 PSK
Downlink coding schemes – CS 1-4, MCS 1-9
Uplink coding schemes – CS 1-4, MCS 1-9
SRB loopback and test mode B
8-bit, 11-bit RACH
PBCCH support
1 phase/2 phase access procedures
Link adaptation and IR
NACC, extended UL TBF
Mobile Station Class B
CSD:
V.110, RLP, non-transparent
• 14.4kbps
• USSD
SMS Point-to-point MT and MO
Cell broadcast
Text and PDU mode
GPS Features
Protocol NMEA
Modes Standalone GPS
Assisted GPS
- Control plane - E911
- User plane - gpsOneXTRA™
General Power saving modes
Software
AT commands Hayes, 3GPP TS 27.007 and 27.005, and proprietary Cinterion Wireless
Modules commands
SIM Application Toolkit SAT Release 99
Audio Audio speech codecs
GSM: AMR, EFR, FR, HR
3GPP: AMR
Speakerphone operation, echo cancellation, noise suppression, 9 ringing
tones, TTY support
Firmware update Generic update from host application over ASC0 or USB
Feature Implementation
PHS8-P Hardware Interface Overview
2.1 Key Features at a Glance
19
PHS8-P_HIO_v01.000 Page 18 of 41 2011-11-10
Confidential / Released
Interfaces
Module interface Surface mount device with solderable connection pads (SMT application
interface).
Land grid array (LGA) technology ensures high solder joint reliability and
provides the possibility to use an optional module mounting socket.
For more information on how to integrate SMT modules see also [11].
This application note comprises chapters on module mounting and appli-
cation layout issues as well as on additional SMT application develop-
ment equipment.
Antenna 50Ohms. Main GSM/UMTS antenna, UMTS diversity antenna, GPS
antenna (active/passive)
USB USB 2.0 High Speed (480Mbit/s) device interface, Full Speed (12Mbit/s)
compliant
Serial interface ASC0:
8-wire modem interface with status and control lines, unbalanced,
asynchronous
Adjustable baud rates from 9,600bps up to 921,600bps
Supports RTS0/CTS0 hardware flow control
Multiplex ability according to GSM 07.10 Multiplexer Protocol
UICC interface Supported chip cards: UICC/SIM/USIM 3V, 1.8V
Status Signal line to indicate network connectivity state
Audio 1 analog interface with microphone feeding
1 digital interface: PCM or I2S
Power on/off, Reset
Power on/off Switch-on by hardware signal IGT
Switch-off by AT command (AT^SMSO)
Automatic switch-off in case of critical temperature or voltage conditions
Reset Orderly shutdown and reset by AT command
Emergency-off Emergency-off by hardware signal EMERG_OFF if IGT is not active
Special Features
Phonebook SIM and phone
TTY/CTM support Integrated CTM modem
Antenna SAIC (Single Antenna Interference Cancellation) / DARP (Downlink
Advanced Receiver Performance)
Rx diversity (receiver type 3i - 16-QAM)1
Evaluation kit
Evaluation module PHS8-P module soldered onto a dedicated PCB that can be connected
to an adapter in order to be mounted onto the DSB75.
DSB75 DSB75 Development Support Board designed to test and type approve
Cinterion Wireless Modules and provide a sample configuration for appli-
cation engineering. A special adapter is required to connect the PHS8-P
evaluation module to the DSB75.
1. UMTS Rx diversity antenna does not support UMTS/HSPA+ band VIII.
Feature Implementation
PHS8-P Hardware Interface Overview
2.2 PHS8-P System Overview
19
PHS8-P_HIO_v01.000 Page 19 of 41 2011-11-10
Confidential / Released
2.2 PHS8-P System Overview
Figure 1: PHS8-P system overview
USB Serial
ASC0
UICC
Analog
audio
Power
supply RTC IGT,
Emergency Off
Net state/
status
SIM
Card
Host Application
Controller On/Off
Module
Application
PSU
or
UMTS
diversity antenna
Power for Application
(VEXT)
Power Indication
(PWR_IND)
Modem Interface
Digital
audio
PCM or I2S
Codec
GSM/UMTS
GPS
GPS antenna
LCI
Low current
indication
GSM/UMTS-
antenna
Wake-
up
Host Wakeup
GPS
active antenna supply,
current limiter
Power
Supply
Application
PHS8-P Hardware Interface Overview
3 Application Interface
29
PHS8-P_HIO_v01.000 Page 20 of 41 2011-11-10
Confidential / Released
3 Application Interface
PHS8-P is equipped with an SMT application interface that connects to the external applica-
tion. The host interface incorporates several sub-interfaces described in the following sections:
Operating modes - see Section 3.1
Power supply - see Section 3.2
Serial interface USB - see Section 3.3
Serial interface ASC0 - Section 3.4
UICC/SIM/USIM interface - see Section 3.5
Analog audio interface - see Section 3.6
Digital audio interface (PCM or I2S) - see Section 3.7
PHS8-P Hardware Interface Overview
3.1 Operating Modes
29
PHS8-P_HIO_v01.000 Page 21 of 41 2011-11-10
Confidential / Released
3.1 Operating Modes
The table below briefly summarizes the various operating modes referred to in the following
chapters.
Table 7: Overview of operating modes
Mode Function
Normal
operation
GSM /
GPRS / UMTS /
HSPA SLEEP
Power saving set automatically when no call is in progress and the USB
connection is suspended by host or not present and no active commu-
nication via ASC0.
GSM /
GPRS / UMTS /
HSPA IDLE
Power saving disabled (see : AT^SCFG "MEopMode/
PwrSave",<PwrSaveMode>) or an USB connection not suspended, but
no call in progress.
GSM TALK/
GSM DATA
Connection between two subscribers is in progress. Power consump-
tion depends on the GSM network coverage and several connection
settings (e.g. DTX off/on, FR/EFR/HR, hopping sequences and
antenna connection). The following applies when power is to be mea-
sured in TALK_GSM mode: DTX off, FR and no frequency hopping.
GPRS DATA GPRS data transfer in progress. Power consumption depends on net-
work settings (e.g. power control level), uplink / downlink data rates and
GPRS configuration (e.g. used multislot settings).
EGPRS DATA EGPRS data transfer in progress. Power consumption depends on net-
work settings (e.g. power control level), uplink / downlink data rates and
EGPRS configuration (e.g. used multislot settings).
UMTS TALK/
UMTS DATA
UMTS data transfer in progress. Power consumption depends on net-
work settings (e.g. TPC Pattern) and data transfer rate.
HSPA DATA HSPA data transfer in progress. Power consumption depends on net-
work settings (e.g. TPC Pattern) and data transfer rate.
Power
Down
Normal shutdown after sending the AT^SMSO command. Only a voltage regulator is active
for powering the RTC. Software is not active. Interfaces are not accessible. Operating volt-
age (connected to BATT+) remains applied.
Airplane
mode
Airplane mode shuts down the radio part of the module, causes the module to log off from
the GSM/GPRS network and disables all AT commands whose execution requires a radio
connection.
Airplane mode can be controlled by AT command (see ).
PHS8-P Hardware Interface Overview
3.2 Power Supply
29
PHS8-P_HIO_v01.000 Page 22 of 41 2011-11-10
Confidential / Released
3.2 Power Supply
PHS8-P needs to be connected to a power supply at the SMT application interface - 6 lines
each BATT+ and GND. There are three separate voltage domains for BATT+:
BATT+_WCDMA with 2 lines for the WCDMA power amplifier supply
BATT+_GSM with 2 lines for the GSM power amplifier supply
BATT+ with 2 lines for the general power management.
The main power supply from an external application has to be a single voltage source and has
to be expanded to three sub paths (star structure). Capacitors should be placed as close as
possible to the BATT+ pads. Figure 2 shows two sample circuits (minimum requirement and
recommended alternative) for decoupling capacitors for BATT+.
Figure 2: Decoupling capacitor(s) for BATT+
The power supply of PHS8-P must be able to provide the peak current during the uplink trans-
mission.
All key functions for supplying power to the device are handled by the power management IC.
It provides the following features:
• Stabilizes the supply voltages for the baseband using switching regulators and low drop lin-
ear voltage regulators.
Switches the module's power voltages for the power-up and -down procedures.
Delivers, across the VEXT line, a regulated voltage for an external application. This voltage
is not available in Power-down mode and can be reduced via AT command to save power.
SIM switch to provide SIM power supply.
BATT+
BATT+
BATT+_GSM
BATT+_WCDMA
2
2
2Decoupling capacitor
e.g. 100…220µF
Ultra-low ESR
Module
GND
SMT interface
+
Minimum requirement
BATT+
2
2
2Decoupling capacitors
e.g. 47µF X5R MLCC
3x
GND
BATT+
BATT+_GSM
BATT+_WCDMA
Module
SMT interface
Recommended alternative
PHS8-P Hardware Interface Overview
3.3 USB Interface
29
PHS8-P_HIO_v01.000 Page 23 of 41 2011-11-10
Confidential / Released
3.3 USB Interface
PHS8-P supports a USB 2.0 High Speed (480Mbit/s) device interface that is Full Speed
(12Mbit/s) compliant. The USB interface is primarily intended for use as command and data
interface and for downloading firmware.
The USB host is responsible for supplying the VUSB_IN line. This line is for voltage detection
only. The USB part (driver and transceiver) is supplied by means of BATT+. This is because
PHS8-P is designed as a self-powered device compliant with the “Universal Serial Bus Speci-
fication Revision 2.0”1.
Figure 3: USB circuit
To properly connect the module's USB interface to the host a USB 2.0 compatible connector is
required. Furthermore, the USB modem driver distributed with PHS8-P needs to be installed.
While the USB connection is active, the module will not change into SLEEP Mode. To enable
switching into SLEEP mode the USB host must bring its USB interface into Suspend state. Al-
so, VUSB_IN should always be kept enabled for this functionality. See “Universal Serial Bus
Specification Revision 2.0“1 for a description of the Suspend state. On incoming calls PHS8-P
will then generate a remote wake up request to resume the USB connection (active low).
As an alternative to the regular USB remote wakeup mechanism it is possible to employ the
RING0 or WAKEUP line to wake up the host application. The benefit is that the RING0 or
WAKEUP lines can wake up the host application in case of incoming calls or other events sig-
nalized by URCs while the USB interface is suspended or shut down.
1. The specification is ready for download on http://www.usb.org/developers/docs/
VBUS
DP
DN
VREG (3V075)
BATT+
USB_DP2)
lin. reg.
GND
Module
Detection only VUSB_IN
USB part1)
RING0
Host wakeup
1) All serial and pull-up resistors for data lines are implemented.
USB_DN2)
2) If the USB interface is operated in High Speed mode (480MHz), it is recommended to take
special care routing the data lines USB_DP and USB_DN. Application layout should in this
case implement a differential impedance of 90Ohm for proper signal integrity.
WAKEUP
SMT
PHS8-P Hardware Interface Overview
3.4 Serial Interface ASC0
29
PHS8-P_HIO_v01.000 Page 24 of 41 2011-11-10
Confidential / Released
3.4 Serial Interface ASC0
PHS8-P offers an 8-wire unbalanced, asynchronous modem interface ASC0 conforming to
ITU-T V.24 protocol DCE signalling. The electrical characteristics do not comply with ITU-T
V.28. The significant levels are 0V (for low data bit or active state) and 1.8V (for high data bit
or inactive state).
PHS8-P is designed for use as a DCE. Based on the conventions for DCE-DTE connections it
communicates with the customer application (DTE) using the following signals:
Port TXD @ application sends data to the module’s TXD0 signal line
Port RXD @ application receives data from the module’s RXD0 signal line
Figure 4: Serial interface ASC0
Features:
Includes the data lines TXD0 and RXD0, the status lines RTS0 and CTS0 and, in addition,
the modem control lines DTR0, DSR0, DCD0 and RING0.
ASC0 is designed for controlling GSM/UMTS voice calls, transferring data and for control-
ling the module with AT commands.
Full multiplexing capability allows the interface to be partitioned into virtual channels.
The RING0 signal serves to indicate incoming calls and other types of URCs (Unsolicited
Result Code). It can also be used to send pulses to the host application, for example to
wake up the application from power saving state. See for details on how to configure the
RING0 line by AT^SCFG.
Configured for 8 data bits, no parity and 1 stop bit.
ASC0 can be operated at fixed bit rates from 9600bps up to 921600bps.
Supports RTS0/CTS0 hardware flow control.
Wake up from SLEEP mode by RTS0 activation (high to low transition).
Note. If the ASC0 serial interface is the application’s only interface, it is suggested to connect
test points on the USB signal lines as a potential tracing possibility.
PHS8-P Hardware Interface Overview
3.4 Serial Interface ASC0
29
PHS8-P_HIO_v01.000 Page 25 of 41 2011-11-10
Confidential / Released
Table 8: DCE-DTE wiring of ASC0
V.24 circuit DCE DTE
Line function Signal direction Line function Signal direction
103 TXD0 Input TXD Output
104 RXD0 Output RXD Input
105 RTS0 Input RTS Output
106 CTS0 Output CTS Input
108/2 DTR0 Input DTR Output
107 DSR0 Output DSR Input
109 DCD0 Output DCD Input
125 RING0 Output RING Input
PHS8-P Hardware Interface Overview
3.5 UICC/SIM/USIM Interface
29
PHS8-P_HIO_v01.000 Page 26 of 41 2011-11-10
Confidential / Released
3.5 UICC/SIM/USIM Interface
PHS8-P has an integrated UICC/SIM/USIM interface compatible with the 3GPP 31.102 and
ETSI 102 221. This is wired to the host interface in order to be connected to an external SIM
card holder. Five pads on the SMT application interface are reserved for the SIM interface.
The UICC/SIM/USIM interface supports 3V and 1.8V SIM cards.
The CCIN signal serves to detect whether a tray (with SIM card) is present in the card holder.
Using the CCIN signal is mandatory for compliance with the GSM 11.11 recommendation if the
mechanical design of the host application allows the user to remove the SIM card during oper-
ation. To take advantage of this feature, an appropriate SIM card detect switch is required on
the card holder. For example, this is true for the model supplied by Molex, which has been test-
ed to operate with PHS8-P and is part of the Cinterion reference equipment submitted for type
approval. See Chapter 9 for Molex ordering numbers.
Note: No guarantee can be given, nor any liability accepted, if loss of data is encountered after
removing the SIM card during operation. Also, no guarantee can be given for properly initializ-
ing any SIM card that the user inserts after having removed the SIM card during operation. In
this case, the application must restart PHS8-P.
Table 9: Signals of the SIM interface (SMT application interface)
Signal Description
GND Separate ground connection for SIM card to improve EMC.
CCCLK Chipcard clock
CCVCC SIM supply voltage.
CCIO Serial data line, input and output.
CCRST Chipcard reset
CCIN Input on the baseband processor for detecting a SIM card tray in the holder. If the SIM is
removed during operation the SIM interface is shut down immediately to prevent destruc-
tion of the SIM. The CCIN signal is active low.
The CCIN signal is mandatory for applications that allow the user to remove the SIM card
during operation.
The CCIN signal is solely intended for use with a SIM card. It must not be used for any other
purposes. Failure to comply with this requirement may invalidate the type approval of
PHS8-P.
PHS8-P Hardware Interface Overview
3.5 UICC/SIM/USIM Interface
29
PHS8-P_HIO_v01.000 Page 27 of 41 2011-11-10
Confidential / Released
Figure 5: UICC/SIM/USIM interface
The total cable length between the SMT application interface pads on PHS8-P and the pads of
the external SIM card holder must not exceed 100mm in order to meet the specifications of
3GPP TS 51.010-1 and to satisfy the requirements of EMC compliance.
To avoid possible cross-talk from the CCCLK signal to the CCIO signal be careful that both
lines are not placed closely next to each other. A useful approach is using the GND line to
shield the CCIO line from the CCCLK line.
Module
open: Card removed
closed: Card inserted
CCRST
CCVCC
CCIO
CCCLK
CCIN
SIM /
UICC
1n
220n
SMT application interface
GND
PHS8-P Hardware Interface Overview
3.6 Analog Audio Interface
29
PHS8-P_HIO_v01.000 Page 28 of 41 2011-11-10
Confidential / Released
3.6 Analog Audio Interface
PHS8-P has an analog audio interface with a balanced analog microphone input and a bal-
anced analog earpiece output. A supply voltage and an analog ground connection are provided
at dedicated lines.
PHS8-P offers eight audio modes which can be selected with the AT^SNFS command. The
electrical characteristics of the voiceband part vary with the audio mode. For example, sending
and receiving amplification, sidetone paths, noise suppression etc. depend on the selected
mode and can in parts be altered with AT commands (except for mode 1).
When shipped from factory, all audio parameters of PHS8-P are set to audio mode 1. This is
the default configuration optimised for the Votronic HH-SI-30.3/V1.1/0 handset and used for
type approving the Cinterion Wireless Modules reference configuration. Audio mode 1 has fix
parameters which cannot be modified. To adjust the settings of the Votronic handset simply
change to another audio mode.
3.7 Digital Audio Interface
PHS8-P supports a digital audio interface that can be employed either as pulse code modula-
tion or as inter IC sound interface. Operation of these interface variants is mutually exclusive.
PHS8-P Hardware Interface Overview
4 GPS Receiver
29
PHS8-P_HIO_v01.000 Page 29 of 41 2011-11-10
Confidential / Released
4 GPS Receiver
PHS8-P integrates a GPS receiver that offers the full performance of GPS technology. The
GPS receiver is able to continuously track all satellites in view, thus providing accurate satellite
position data.
The integrated GPS receiver supports the NMEA protocol via USB or ASC0 interface. NMEA
is a combined electrical and data specification for communication between various (marine)
electronic devices including GPS receivers. It has been defined and controlled by the US-
based National Marine Electronics Association. For more information on the NMEA Standard
please refer to http://www.nmea.org.
Depending on the receiver’s knowledge of last position, current time and ephemeris data, the
receiver’s startup time (i.e., TTFF = Time-To-First-Fix) may vary: If the receiver has no knowl-
edge of its last position or time, a startup takes considerably longer than if the receiver has still
knowledge of its last position, time and almanac or has still access to valid ephimeris data and
the precise time.
By default, the GPS receiver is switched off. It has to be switched on and configured using AT
commands. For more information on how to control the GPS interface via the AT command
AT^SGPSC see .
PHS8-P Hardware Interface Overview
5 Antenna Interfaces
33
PHS8-P_HIO_v01.000 Page 30 of 41 2011-11-10
Confidential / Released
5 Antenna Interfaces
5.1 GSM/UMTS Antenna Interface
The PHS8-P GSM/UMTS antenna interface comprises a main GSM/UMTS antenna as well as
an optional UMTS Rx diversity antenna to improve signal reliability and quality1. The interface
has an impedance of 50. PHS8-P is capable of sustaining a total mismatch at the antenna
interface without any damage, even when transmitting at maximum RF power.
The external antenna must be matched properly to achieve best performance regarding radi-
ated power, modulation accuracy and harmonic suppression. Matching networks are not in-
cluded on the PHS8-P PCB and should be placed in the host application, if the antenna does
not have an impendance of 50.
Regarding the return loss PHS8-P provides the following values in the active band:
1. By delivery default the optional UMTS Rx diversity antenna is configured as available for the module. To
avoid negative side effects and performance degradation it is recommended to disable the diversity an-
tenna path if
- the host application does not support a diversity antenna
- the host application includes a diversity antenna - but a 3G network simulator is used for development
and performance tests.
Please refer to [1] for details on how to configure antenna settings.
Table 10: Return loss in the active band
State of module Return loss of module Recommended return loss of application
Receive > 8dB > 12dB
Transmit not applicable > 12dB
Idle < 5dB not applicable
PHS8-P Hardware Interface Overview
5.1 GSM/UMTS Antenna Interface
33
PHS8-P_HIO_v01.000 Page 31 of 41 2011-11-10
Confidential / Released
5.1.1 Antenna Installation
The antenna is connected by soldering the antenna pads and their neighboring ground pads
directly to the application’s PCB.
The distance between the antenna pads and their neighboring GND pads has been optimized
for best possible impedance. To prevent mismatch, special attention should be paid to these
pads on the application’ PCB.
The wiring of the antenna connection, starting from the antenna pad to the application’s anten-
na should result in a 50 line impedance. Line width and distance to the GND plane need to
be optimized with regard to the PCB’s layer stack.
To prevent receiver desensitization due to interferences generated by fast transients like high
speed clocks on the external application PCB, it is recommended to realize the antenna con-
nection line using embedded Stripline rather than Micro-Stripline technology.
For type approval purposes, the use of a 50 coaxial antenna connector (U.FL-R-SMT) might
be necessary. In this case the U.FL-R-SMT connector should be placed as close as possible
to PHS8-P‘s antenna pad.
PHS8-P Hardware Interface Overview
5.2 GPS Antenna Interface
33
PHS8-P_HIO_v01.000 Page 32 of 41 2011-11-10
Confidential / Released
5.2 GPS Antenna Interface
In addition to the RF antenna interface PHS8-P also has a GPS antenna interface. The GPS
antenna installation and connector are the same as for the RF antenna interface (see Section
5.1.1).
It is possible to connect active or passive GPS antennas. In either case they must have 50 Ohm
impedance. The simultaneous operation of GSM and GPS has been implemented.
PHS8-P provides the supply voltage VGPS for the GPS active antenna (3.05V). It has to be
enabled by software when the GPS-receiver shall becomes active, otherwise VGPS should be
off (power saving). VGPS is not short circuit protected. This will have to be provided for by an
external application. The DC voltage should be fed back via ANT_GPS_DC for coupling into
the GPS antenna path. Figure 6 shows the flexibility in realizing the power supply for an active
GPS antenna by giving two sample circuits realizing the supply voltage for an active GPS an-
tenna - one with short circuit protection and one with an external LDO employed.
Figure 6: Supply voltage for active GPS antenna
LDO
VGPS
ANT_GPS
Active
GPS
antenna
10nH
47pF
2p2
Module
SMT interface
ANT_GPS_DC
1uF
(Optional)
ESD
protection
10k
Enable
External
voltage
Supply with external LDO employed
PHS8-P Hardware Interface Overview
5.2 GPS Antenna Interface
33
PHS8-P_HIO_v01.000 Page 33 of 41 2011-11-10
Confidential / Released
Figure 7 shows sample circuits realizing ESD protection for a passive GPS antenna.
Figure 7: ESD protection for passive GPS antenna
VGPS
ANT_GPS
Passive
GPS
antenna
10nH
47pF
2p2
Module
SMT interface
ANT_GPS_DC (Optional)
ESD
protection
0R
Not used
PHS8-P Hardware Interface Overview
6 Mechanics
35
PHS8-P_HIO_v01.000 Page 34 of 41 2011-11-10
Confidential / Released
6 Mechanics
6.1 Mechanical Dimensions of PHS8-P
Figure 8 shows the top view of PHS8-P and provides an overview of the board's mechanical
dimensions. For further details see Figure 9.
Length: 33mm
Width: 29mm
Height: 2mm
Figure 8: PHS8-P – top view
Top view
Bottom view
PHS8-P Hardware Interface Overview
6.1 Mechanical Dimensions of PHS8-P
35
PHS8-P_HIO_v01.000 Page 35 of 41 2011-11-10
Confidential / Released
Figure 9: Dimensions of PHS8-P (all dimensions in mm)
Internal use;
Not to be soldered
Position marker
PHS8-P Hardware Interface Overview
7 Sample Application
37
PHS8-P_HIO_v01.000 Page 36 of 41 2011-11-10
Confidential / Released
7 Sample Application
Figure 10 shows a typical example of how to integrate an PHS8-P module with an application.
The audio interface demonstrates the balanced connection of microphone and earpiece. This
solution is particularly well suited for internal transducers.
The PWR_IND line is an open collector that needs an external pull-up resistor which connects
to the voltage supply VCC µC of the microcontroller. Low state of the open collector pulls the
PWR_IND signal low and indicates that the PHS8-P module is active, high level notifies the
Power-down mode.
If the module is in Power-down mode avoid current flowing from any other source into the mod-
ule circuit, for example reverse current from high state external control lines. Therefore, the
controlling application must be designed to prevent reverse flow. If an external level controller
is required, this can be done by using for example a 5V I/O tolerant buffer/driver like a
"74AVC4T245" with OE (Output Enable) controlled by PWR_IND.
While developing SMT applications it is strongly recommended to provide test points
for certain signals resp. lines to and from the module - for debug and/or test purposes.
The SMT application should allow for an easy access to these signals. For details on
how to implement test points see [4].
The EMC measures are best practice recommendations. In fact, an adequate EMC strategy for
an individual application is very much determined by the overall layout and, especially, the po-
sition of components.
Disclaimer:
No warranty, either stated or implied, is provided on the sample schematic diagram shown in
Figure 10 and the information detailed in this section. As functionality and compliance with na-
tional regulations depend to a great amount on the used electronic components and the indi-
vidual application layout manufacturers are required to ensure adequate design and operating
safeguards for their products using PHS8-P modules.
PHS8-P Hardware Interface Overview
7 Sample Application
37
PHS8-P_HIO_v01.000 Page 37 of 41 2011-11-10
Confidential / Released
Figure 10: PHS8-P sample application
47k
100k
VCC µC
47k
EMERG_RST
PWR_IND
CCCLK
CCRST
CCIN
CCVCC
220nF
AGND
EPP
BC847
BC847
1nF
PHS8 ApplicationSample
2
2
2
2
8
Level
Controller
8
VEXT (1.8V)
1µF
1µF
V
CCB
V
CCA
VCC µC
VDD
(1.8V)
100µF
...220µF
ultra low ESR
ANT_DRX
ANT_GSM
ANT_GPS
Current
limiter
<60mA
VGPS
OE
PHS8-P Hardware Interface Overview
8 Reference Approval
39
PHS8-P_HIO_v01.000 Page 38 of 41 2011-11-10
Confidential / Released
8 Reference Approval
8.1 Reference Equipment for Type Approval
The Cinterion Wireless Modules reference setup submitted to type approve PHS8-P is shown
in the following figure1. The module (i.e., the evaluation module) is connected to the DSB75 via
a special adapter and either mounted directly onto the adapter or connected using a flex cable:
Figure 11: Reference equipment for type approval
1. For RF performance tests a mini-SMT/U.FL to SMA adapter with attached 6dB coaxial attenuator is cho-
sen to connect the module directly to the GSM/UMTS/GPS test equipment instead of employing the SMA
antenna connectors on the PHS8-P-DSB75 adapter as shown in Figure 11. The following products are
recommended:
Hirose SMA-Jack/U.FL-Plug conversion adapter HRMJ-U.FLP(40)
(for details see see http://www.hirose-connectors.com/ or http://www.farnell.com/
Aeroflex Weinschel Fixed Coaxial Attenuator Model 3T/4T
(for details see http://www.aeroflex.com/ams/weinschel/pdfiles/wmod3&4T.pdf)
DSB75
Standard
80 polig Flex
PC
GSM/UMTS
test equipment
GPS
test equipment
GSM/UMTS
RS232
cable
USB
cable
Audio
test equipment
Votronic
handset
Power
supply
COM1
(ASC0)
Power
GND
USB
ANT3
ANT2
ANT1
Audio
Uranus
Audio
DSB75 adapter
SIM card
holder
PHS8
evaluation
module
Hirose U.FL RF connector
manually soldered to Pogo pads
Detail:
Hirose U.FL cable
UMTS DRX
GPS
If using analog audio
PHS8
evaluation
module
PHS8-P Hardware Interface Overview
8.2 Compliance with FCC and IC Rules and Regulations
39
PHS8-P_HIO_v01.000 Page 39 of 41 2011-11-10
Confidential / Released
8.2 Compliance with FCC and IC Rules and Regulations
The Equipment Authorization Certification for the Cinterion Wireless Modules reference appli-
cation described in Section 8.1 will be registered under the following identifiers:
FCC Identifier QIPPHS8-P
Industry Canada Certification Number: 7830A-PHS8P
Granted to Cinterion Wireless Modules GmbH
Manufacturers of mobile or fixed devices incorporating PHS8-P modules are authorized to use
the FCC Grants and Industry Canada Certificates of the PHS8-P modules for their own final
products according to the conditions referenced in these documents. In this case, the FCC la-
bel of the module shall be visible from the outside, or the host device shall bear a second label
stating "Contains FCC ID QIPPHS8-P", and accordingly “Contains IC 7830A-PHS8P“. The in-
tegration is limited to fixed or mobile categorised host devices, where a separation distance be-
tween the antenna and any person of min. 20cm can be assured during normal operating
conditions. For mobile and fixed operation configurations the antenna gain, including cable
loss, must not exceed the limits that are stated on the FCC Grant.
IMPORTANT:
Manufacturers of portable applications incorporating PHS8-P modules are required to have
their final product certified and apply for their own FCC Grant and Industry Canada Certificate
related to the specific portable mobile. This is mandatory to meet the SAR requirements for por-
table mobiles.
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
PHS8-P Hardware Interface Overview
9 Appendix
41
PHS8-P_HIO_v01.000 Page 40 of 41 2011-11-10
Confidential / Released
9 Appendix
9.1 List of Parts and Accessories
Table 11: List of parts and accessories
Description Supplier Ordering information
PHS8-P Cinterion Standard module
Cinterion Wireless Modules IMEI:
Ordering number: L30960-N2410-A100
Customer IMEI:
Ordering number: L30960-N2415-A100
DSB75 Support Box Cinterion Ordering number: L36880-N8811-A100
DSB75 adapter for mounting
the PHS8-P evaluation mod-
ule
Cinterion Ordering number: L30960-N1802-A100
Votronic Handset VOTRONIC Votronic HH-SI-30.3/V1.1/0
VOTRONIC
Entwicklungs- und Produktionsgesellschaft für elek-
tronische Geräte mbH
Saarbrücker Str. 8
66386 St. Ingbert
Germany
Phone: +49-(0)6 89 4 / 92 55-0
Fax: +49-(0)6 89 4 / 92 55-88
Email: contact@votronic.com
SIM card holder incl. push
button ejector and slide-in
tray
Molex Ordering numbers: 91228
91236
Sales contacts are listed in Table 12.
Board-to-board connector Molex Sales contacts are listed in Table 12.
U.FL antenna connector Hirose or Molex Sales contacts are listed in Table 12 and Table 13.
PHS8-P Hardware Interface Overview
9.1 List of Parts and Accessories
41
PHS8-P_HIO_v01.000 Page 41 of 41 2011-11-10
Confidential / Released
Table 12: Molex sales contacts (subject to change)
Molex
For further information please click:
http://www.molex.com
Molex Deutschland GmbH
Otto-Hahn-Str. 1b
69190 Walldorf
Germany
Phone: +49-6227-3091-0
Fax: +49-6227-3091-8100
Email: mxgermany@molex.com
American Headquarters
Lisle, Illinois 60532
U.S.A.
Phone: +1-800-78MOLEX
Fax: +1-630-969-1352
Molex China Distributors
Beijing,
Room 1311, Tower B, COFCO Plaza
No. 8, Jian Guo Men Nei Street, 100005
Beijing
P.R. China
Phone: +86-10-6526-9628
Fax: +86-10-6526-9730
Molex Singapore Pte. Ltd.
110, International Road
Jurong Town,
Singapore 629174
Phone: +65-6-268-6868
Fax: +65-6-265-6044
Molex Japan Co. Ltd.
1-5-4 Fukami-Higashi,
Yamato-City,
Kanagawa, 242-8585
Japan
Phone: +81-46-265-2325
Fax: +81-46-265-2365
Table 13: Hirose sales contacts (subject to change)
Hirose Ltd.
For further information please click:
http://www.hirose.com
Hirose Electric (U.S.A.) Inc
2688 Westhills Court
Simi Valley, CA 93065
U.S.A.
Phone: +1-805-522-7958
Fax: +1-805-522-3217
Hirose Electric Europe B.V.
German Branch:
Herzog-Carl-Strasse 4
73760 Ostfildern
Germany
Phone: +49-711-456002-1
Fax: +49-711-456002-299
Email: info@hirose.de
Hirose Electric Europe B.V.
UK Branch:
First Floor, St. Andrews House,
Caldecotte Lake Business Park,
Milton Keynes MK7 8LE
Great Britain
Phone: +44-1908-369060
Fax: +44-1908-369078
Hirose Electric Co., Ltd.
5-23, Osaki 5 Chome,
Shinagawa-Ku
Tokyo 141
Japan
Phone: +81-03-3491-9741
Fax: +81-03-3493-2933
Hirose Electric Europe B.V.
Hogehillweg 8
1101 CC Amsterdam Z-O
Netherlands
Phone: +31-20-6557-460
Fax: +31-20-6557-469

Navigation menu