THALES DIS AlS Deutschland PXS8 GSM/GPRS/EDGE/CDMA/UMTS/HSPA Module User Manual hid
Gemalto M2M GmbH GSM/GPRS/EDGE/CDMA/UMTS/HSPA Module hid
Contents
- 1. integration manual
- 2. user manual
user manual
PXS8 Version: DocId: 03.000 PXS8_HD_v03.000 Hardware Interface Description PXS8 Hardware Interface Description Document Name: PXS8 Hardware Interface Description Version: 03.000 Date: 2012-11-30 DocId: PXS8_HD_v03.000 Status Confidential / Preliminary GENERAL NOTE THE USE OF THE PRODUCT INCLUDING THE SOFTWARE AND DOCUMENTATION (THE "PRODUCT") IS SUBJECT TO THE RELEASE NOTE PROVIDED TOGETHER WITH PRODUCT. IN ANY EVENT THE PROVISIONS OF THE RELEASE NOTE SHALL PREVAIL. THIS DOCUMENT CONTAINS INFORMATION ON CINTERION PRODUCTS. THE SPECIFICATIONS IN THIS DOCUMENT ARE SUBJECT TO CHANGE AT CINTERION'S DISCRETION. CINTERION WIRELESS MODULES GMBH GRANTS A NON-EXCLUSIVE RIGHT TO USE THE PRODUCT. THE RECIPIENT SHALL NOT TRANSFER, COPY, MODIFY, TRANSLATE, REVERSE ENGINEER, CREATE DERIVATIVE WORKS; DISASSEMBLE OR DECOMPILE THE PRODUCT OR OTHERWISE USE THE PRODUCT EXCEPT AS SPECIFICALLY AUTHORIZED. THE PRODUCT AND THIS DOCUMENT ARE PROVIDED ON AN "AS IS" BASIS ONLY AND MAY CONTAIN DEFICIENCIES OR INADEQUACIES. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, CINTERION WIRELESS MODULES GMBH DISCLAIMS ALL WARRANTIES AND LIABILITIES. THE RECIPIENT UNDERTAKES FOR AN UNLIMITED PERIOD OF TIME TO OBSERVE SECRECY REGARDING ANY INFORMATION AND DATA PROVIDED TO HIM IN THE CONTEXT OF THE DELIVERY OF THE PRODUCT. THIS GENERAL NOTE SHALL BE GOVERNED AND CONSTRUED ACCORDING TO GERMAN LAW. Copyright Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. Copyright © 2012, Cinterion Wireless Modules GmbH Trademark Notice Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. CDMA2000 is a registered certification mark of the Telecommunications Industry Association. All other registered trademarks or trademarks mentioned in this document are property of their respective owners. PXS8_HD_v03.000 Confidential / Preliminary Page 2 of 41 2012-11-30 PXS8 Hardware Interface Description Contents 41 Contents Introduction ................................................................................................................. 6 1.1 Related Documents ........................................................................................... 6 1.2 Terms and Abbreviations ................................................................................... 6 1.3 Regulatory and Type Approval Information ..................................................... 10 1.3.1 Directives and Standards.................................................................... 10 1.3.2 SAR requirements specific to portable mobiles .................................. 13 1.3.3 SELV Requirements ........................................................................... 14 1.3.4 Safety Precautions.............................................................................. 14 Product Concept ....................................................................................................... 16 2.1 Key Features at a Glance ................................................................................ 16 2.2 PXS8 System Overview................................................................................... 19 Application Interface................................................................................................. 20 3.1 Operating Modes ............................................................................................. 21 3.2 Power Supply................................................................................................... 22 3.3 USB Interface................................................................................................... 23 3.4 Serial Interface ASC0 ...................................................................................... 24 3.5 UICC/SIM/USIM Interface................................................................................ 26 3.6 Analog Audio Interface..................................................................................... 28 3.7 Digital Audio Interface...................................................................................... 28 GNSS Receiver .......................................................................................................... 29 Antenna Interfaces.................................................................................................... 30 5.1 GSM/UMTS/CDMA Antenna Interface............................................................. 30 5.1.1 Antenna Installation ............................................................................ 31 5.2 GNSS Antenna Interface ................................................................................. 32 Mechanics, Mounting and Packaging ..................................................................... 34 6.1 Mechanical Dimensions of PXS8..................................................................... 34 Sample Application................................................................................................... 36 Reference Approval .................................................................................................. 38 8.1 Reference Equipment for Type Approval ......................................................... 38 8.2 Compliance with FCC and IC Rules and Regulations ..................................... 39 Appendix.................................................................................................................... 40 9.1 List of Parts and Accessories........................................................................... 40 PXS8_HD_v03.000 Confidential / Preliminary Page 3 of 41 2012-11-30 PXS8 Hardware Interface Description Tables 41 Tables Table 1: Table 2: Table 3: Table 4: Table 5: Table 6: Table 7: Table 8: Table 9: Table 10: Table 11: Table 12: Table 13: Directives ....................................................................................................... Standards of North American type approval .................................................. Standards of European type approval............................................................ Requirements of quality ................................................................................. Standards of the Ministry of Information Industry of the People’s Republic of China ............................................................................ Toxic or hazardous substances or elements with defined concentration limits ............................................................................................................... Overview of operating modes ........................................................................ DCE-DTE wiring of ASC0 .............................................................................. Signals of the SIM interface (SMT application interface) ............................... Return loss in the active band........................................................................ List of parts and accessories.......................................................................... Molex sales contacts (subject to change) ...................................................... Hirose sales contacts (subject to change) ..................................................... PXS8_HD_v03.000 Confidential / Preliminary Page 4 of 41 10 10 10 11 11 12 21 25 26 30 40 41 41 2012-11-30 PXS8 Hardware Interface Description Figures 41 Figures Figure 1: Figure 2: Figure 3: Figure 4: Figure 5: Figure 6: Figure 7: Figure 8: Figure 9: Figure 10: Figure 11: PXS8 system overview .................................................................................. Decoupling capacitor(s) for BATT+................................................................ USB circuit ..................................................................................................... Serial interface ASC0..................................................................................... UICC/SIM/USIM interface .............................................................................. Supply voltage for active GNSS antenna....................................................... ESD protection for passive GNSS antenna ................................................... PXS8 – top and bottomview........................................................................... Dimensions of PXS8 (all dimensions in mm) ................................................. PXS8 sample application ............................................................................... Reference equipment for type approval ......................................................... PXS8_HD_v03.000 Confidential / Preliminary Page 5 of 41 19 22 23 24 27 32 33 34 35 37 38 2012-11-30 PXS8 Hardware Interface Description 1 Introduction 15 Introduction The document1 describes the hardware of the PXS8 module, designed to connect to a cellular device application and the air interface. It helps you quickly retrieve interface specifications, electrical and mechanical details and information on the requirements to be considered for integrating further components. 1.1 [1] [2] [3] [4] [5] Related Documents PXS8 AT Command Set PXS8 Release Notes DSB75 Support Box - Evaluation Kit for Cinterion Wireless Modules Application Note 48: SMT Module Integration Universal Serial Bus Specification Revision 2.0, April 27, 2000 1.2 Terms and Abbreviations Abbreviation Description AGPS Assisted GPS ANSI American National Standards Institute AMR Adaptive Multirate ARP Antenna Reference Point BB Baseband BC Band Class BEP Bit Error Probability BTS Base Transceiver Station CB or CBM Cell Broadcast Message CDMA Code Division Multiple Access CE Conformité Européene (European Conformity) CS Coding Scheme CS Circuit Switched CSD Circuit Switched Data CTM Cellular Text Modem DAC Digital-to-Analog Converter DCS Digital Cellular System 1. The document is effective only if listed in the appropriate Release Notes as part of the technical documentation delivered with your Cinterion Wireless Modules product. PXS8_HD_v03.000 Confidential / Preliminary Page 6 of 41 2012-11-30 PXS8 Hardware Interface Description 1.2 Terms and Abbreviations 15 Abbreviation Description DL Download DRX Discontinuous Reception DSB Development Support Board DSP Digital Signal Processor DTMF Dual Tone Multi Frequency DTX Discontinuous Transmission EDGE Enhanced Data rates for GSM Evolution EFR Enhanced Full Rate EGSM Extended GSM EMC Electromagnetic Compatibility ERP Effective Radiated Power ESD Electrostatic Discharge ETS European Telecommunication Standard ETSI European Telecommunications Standards Institute EVRC Enhanced Variable Rate Codec FCC Federal Communications Commission (U.S.) FDD Frequency Division Duplex FDMA Frequency Division Multiple Access FL Forward Link FR Full Rate GLONASS Globalnaja Nawigazionnaja Sputnikowaja Sistema GNSS Global Navigation Satellite System GPRS General Packet Radio Service GPS Global Positioning System GSM Global Standard for Mobile Communications HiZ High Impedance HSDPA High Speed Downlink Packet Access HR Half Rate I/O Input/Output IF Intermediate Frequency IMEI International Mobile Equipment Identity ISO International Standards Organization ITU International Telecommunications Union kbps kbits per second LED Light Emitting Diode LGA Land Grid Array PXS8_HD_v03.000 Confidential / Preliminary Page 7 of 41 2012-11-30 PXS8 Hardware Interface Description 1.2 Terms and Abbreviations 15 Abbreviation Description MBB Moisture barrier bag Mbps Mbits per second MCS Modulation and Coding Scheme MO Mobile Originated MS Mobile Station, also referred to as TE MSL Moisture Sensitivity Level MT Mobile Terminated NB Narrow Band NMEA National Marine Electronics Association NTC Negative Temperature Coefficient PBCCH Packet Switched Broadcast Control Channel PCB Printed Circuit Board PCL Power Control Level PCM Pulse Code Modulation PCS Personal Communication System, also referred to as GSM 1900 PD Pull Down resistor (appr. 100k) PDU Protocol Data Unit PS Packet Switched PSK Phase Shift Keying PU Pull Up resistor (appr. 100k) QAM Quadrature Amplitude Modulation R&TTE Radio and Telecommunication Terminal Equipment RF Radio Frequency RL Reverse Link ROPR Radio Output Power Reduction RTC Real Time Clock Rx Receive Direction SAR Specific Absorption Rate SCI Slot Cycle Index SELV Safety Extra Low Voltage SIM Subscriber Identification Module SLIC Subscriber Line Interface Circuit SMPL Sudden Momentary Power Loss SMD Surface Mount Device SMS Short Message Service SMT Surface Mount Technology PXS8_HD_v03.000 Confidential / Preliminary Page 8 of 41 2012-11-30 PXS8 Hardware Interface Description 1.2 Terms and Abbreviations 15 Abbreviation Description SNR Signal-to-Noise Ratio SRAM Static Random Access Memory SRB Signalling Radio Bearer SUPL Secure User Plane Location TDMA Time Division Multiple Access TE Terminal Equipment TPC Transmit Power Control TS Technical Specification TTFF Time To First Fix Tx Transmit Direction UL Upload UMTS Universal Mobile Telecommunications System URC Unsolicited Result Code USB Universal Serial Bus UICC USIM Integrated Circuit Card USIM UMTS Subscriber Identification Module WCDMA Wideband Code Division Multiple Access PXS8_HD_v03.000 Confidential / Preliminary Page 9 of 41 2012-11-30 PXS8 Hardware Interface Description 1.3 Regulatory and Type Approval Information 15 1.3 Regulatory and Type Approval Information 1.3.1 Directives and Standards PXS8 has been designed to comply with the directives and standards listed below. It is the responsibility of the application manufacturer to ensure compliance of the final product with all provisions of the applicable directives and standards as well as with the technical specifications provided in the "PXS8 Hardware Interface Description".1 Table 1: Directives 99/05/EC Directive of the European Parliament and of the council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (in short referred to as R&TTE Directive 1999/5/EC). The product is labeled with the CE conformity mark 2002/95/EC Directive of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) Table 2: Standards of North American type approval CFR Title 47 Code of Federal Regulations, Part 22, Part 24 and Part 27; US Equipment Authorization FCC OET Bulletin 65 (Edition 97-01) Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields UL 60 950-1 Product Safety Certification (Safety requirements) NAPRD.03 V5.11 Overview of PCS Type certification review board Mobile Equipment Type Certification and IMEI control PCS Type Certification Review board (PTCRB) RSS132, RSS133, RSS139 Canadian Standard Table 3: Standards of European type approval 3GPP TS 51.010-1 Digital cellular telecommunications system (Release 7); Mobile Station (MS) conformance specification; ETSI EN 301 511 V9.0.2 Global System for Mobile communications (GSM); Harmonized standard for mobile stations in the GSM 900 and DCS 1800 bands covering essential requirements under article 3.2 of the R&TTE directive (1999/5/EC) GCF-CC V3.45 Global Certification Forum - Certification Criteria ETSI EN 301 489-01 V1.8.1 Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common Technical Requirements 1. Manufacturers of applications which can be used in the US shall ensure that their applications have a PTCRB approval. For this purpose they can refer to the PTCRB approval of the respective module. PXS8_HD_v03.000 Confidential / Preliminary Page 10 of 41 2012-11-30 PXS8 Hardware Interface Description 1.3 Regulatory and Type Approval Information 15 Table 3: Standards of European type approval ETSI EN 301 489-03 V1.4.1 Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz ETSI EN 301 489-07 V1.3.1 Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS) ETSI EN 301 489-24 V1.4.1 Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 24: Specific conditions for IMT-2000 CDMA Direct Spread (UTRA) for Mobile and portable (UE) radio and ancillary equipment ETSI EN 301 908-01 V4.2.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); Base Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation cellular networks; Part 1: Harmonized EN for IMT-2000, introduction and common requirements of article 3.2 of the R&TTE Directive ETSI EN 301 908-02 V4.2.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); Base Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation cellular networks; Part 2: Harmonized EN for IMT-2000, CDMA Direct Spread (UTRA FDD) (UE) covering essential requirements of article 3.2 of the R&TTE Directive EN 300 440-02 V1.3.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 2: Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive EN 62311:2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) IEC/EN 60950-1:2006 Safety of information technology equipment Table 4: Requirements of quality IEC 60068 Environmental testing DIN EN 60529 IP codes Table 5: Standards of the Ministry of Information Industry of the People’s Republic of China SJ/T 11363-2006 “Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products” (2006-06). SJ/T 11364-2006 “Marking for Control of Pollution Caused by Electronic Information Products” (2006-06). According to the “Chinese Administration on the Control of Pollution caused by Electronic Information Products” (ACPEIP) the EPUP, i.e., Environmental Protection Use Period, of this product is 20 years as per the symbol shown here, unless otherwise marked. The EPUP is valid only as long as the product is operated within the operating limits described in the Cinterion Hardware Interface Description. Please see Table 6 for an overview of toxic or hazardous substances or elements that might be contained in product parts in concentrations above the limits defined by SJ/T 11363-2006. PXS8_HD_v03.000 Confidential / Preliminary Page 11 of 41 2012-11-30 PXS8 Hardware Interface Description 1.3 Regulatory and Type Approval Information 15 Table 6: Toxic or hazardous substances or elements with defined concentration limits PXS8_HD_v03.000 Confidential / Preliminary Page 12 of 41 2012-11-30 PXS8 Hardware Interface Description 1.3 Regulatory and Type Approval Information 15 1.3.2 SAR requirements specific to portable mobiles Mobile phones, PDAs or other portable transmitters and receivers incorporating a GSM/CDMA module must be in accordance with the guidelines for human exposure to radio frequency energy. This requires the Specific Absorption Rate (SAR) of portable PXS8 based applications to be evaluated and approved for compliance with national and/or international regulations. Since the SAR value varies significantly with the individual product design manufacturers are advised to submit their product for approval if designed for portable use. For European and USmarkets the relevant directives are mentioned below. It is the responsibility of the manufacturer of the final product to verify whether or not further standards, recommendations or directives are in force outside these areas. Products intended for sale on US markets ES 59005/ANSI C95.1 Considerations for evaluation of human exposure to electromagnetic fields (EMFs) from mobile telecommunication equipment (MTE) in the frequency range 30MHz - 6GHz Products intended for sale on European markets EN 50360 Product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human exposure to electromagnetic fields (300MHz - 3GHz) IMPORTANT: Manufacturers of portable applications based on PXS8 modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable mobile. PXS8_HD_v03.000 Confidential / Preliminary Page 13 of 41 2012-11-30 PXS8 Hardware Interface Description 1.3 Regulatory and Type Approval Information 15 1.3.3 SELV Requirements The power supply connected to the PXS8 module shall be in compliance with the SELV requirements defined in EN 60950-1. 1.3.4 Safety Precautions The following safety precautions must be observed during all phases of the operation, usage, service or repair of any cellular terminal or mobile incorporating PXS8. Manufacturers of the cellular terminal are advised to convey the following safety information to users and operating personnel and to incorporate these guidelines into all manuals supplied with the product. Failure to comply with these precautions violates safety standards of design, manufacture and intended use of the product. Cinterion Wireless Modules assumes no liability for customer’s failure to comply with these precautions. When in a hospital or other health care facility, observe the restrictions on the use of mobiles. Switch the cellular terminal or mobile off, if instructed to do so by the guidelines posted in sensitive areas. Medical equipment may be sensitive to RF energy. The operation of cardiac pacemakers, other implanted medical equipment and hearing aids can be affected by interference from cellular terminals or mobiles placed close to the device. If in doubt about potential danger, contact the physician or the manufacturer of the device to verify that the equipment is properly shielded. Pacemaker patients are advised to keep their hand-held mobile away from the pacemaker, while it is on. Switch off the cellular terminal or mobile before boarding an aircraft. Make sure it cannot be switched on inadvertently. The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems. Failure to observe these instructions may lead to the suspension or denial of cellular services to the offender, legal action, or both. Do not operate the cellular terminal or mobile in the presence of flammable gases or fumes. Switch off the cellular terminal when you are near petrol stations, fuel depots, chemical plants or where blasting operations are in progress. Operation of any electrical equipment in potentially explosive atmospheres can constitute a safety hazard. Your cellular terminal or mobile receives and transmits radio frequency energy while switched on. Remember that interference can occur if it is used close to TV sets, radios, computers or inadequately shielded equipment. Follow any special regulations and always switch off the cellular terminal or mobile wherever forbidden, or when you suspect that it may cause interference or danger. Road safety comes first! Do not use a hand-held cellular terminal or mobile when driving a vehicle, unless it is securely mounted in a holder for speakerphone operation. Before making a call with a hand-held terminal or mobile, park the vehicle. Speakerphones must be installed by qualified personnel. Faulty installation or operation can constitute a safety hazard. PXS8_HD_v03.000 Confidential / Preliminary Page 14 of 41 2012-11-30 PXS8 Hardware Interface Description 1.3 Regulatory and Type Approval Information 15 IMPORTANT! Cellular terminals or mobiles operate using radio signals and cellular networks. Because of this, connection cannot be guaranteed at all times under all conditions. Therefore, you should never rely solely upon any wireless device for essential communications, for example emergency calls. Remember, in order to make or receive calls, the cellular terminal or mobile must be switched on and in a service area with adequate cellular signal strength. Some networks do not allow for emergency calls if certain network services or phone features are in use (e.g. lock functions, fixed dialing etc.). You may need to deactivate those features before you can make an emergency call. Some networks require that a valid SIM card be properly inserted in the cellular terminal or mobile. Bear in mind that exposure to excessive levels of noise can cause physical damage to users! With regard to acoustic shock, the cellular application must be designed to avoid unintentional increase of amplification, e.g. for a highly sensitive earpiece. A protection circuit should be implemented in the cellular application. PXS8_HD_v03.000 Confidential / Preliminary Page 15 of 41 2012-11-30 PXS8 Hardware Interface Description 2 Product Concept 19 Product Concept 2.1 Key Features at a Glance Feature Implementation General Frequency bands GSM/GPRS/EDGE: Quad band, 850/900/1800/1900MHz UMTS/HSPA+: Five band, 800/850/900/1900/2100MHz CDMA: Triple band (BC0/BC1 and BC10 subclass 2+3), 800/1900MHz GSM class Small MS Output power (according to Class 4 (+33dBm ±2dB) for EGSM850 Release 99) Class 4 (+33dBm ±2dB) for EGSM900 Class 1 (+30dBm ±2dB) for GSM1800 Class 1 (+30dBm ±2dB) for GSM1900 Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK Class 3 (+24dBm +1/-3dB) for UMTS 2100, WCDMA FDD BdI Class 3 (+24dBm +1/-3dB) for UMTS 1900,WCDMA FDD BdII Class 3 (+24dBm +1/-3dB) for UMTS 900, WCDMA FDD BdVIII Class 3 (+24dBm +1/-3dB) for UMTS 850, WCDMA FDD BdV Class 3 (+24dBm +1/-3dB) for UMTS 800, WCDMA FDD BdVI Power supply 3.3V < VBATT+ < 4.2V Operating temperature (board temperature) Normal operation: -30°C to +85°C Restricted operation: -40°C to +95°C Physical Dimensions: 33mm x 29mm x 2mm Weight: approx. 5g RoHS All hardware components fully compliant with EU RoHS Directive CDMA features 3GPP2 CDMA2000 EV-DO Rev.A data rates: FL max. 3.1Mbps, RL max. 1.8Mbps 1xRTT Advanced data rates: FL max. 307.2kbps, RL max. 307.2kbps HSPA features 3GPP Release 6, 7 DL 14.4Mbps, UL 5.7Mbps UE CAT. 1-12 supported Compressed mode (CM) supported according to 3GPP TS25.212 UMTS features 3GPP Release 4 PXS8_HD_v03.000 Confidential / Preliminary PS data rate – 384 kbps DL / 384 kbps UL CS data rate – 64 kbps DL / 64 kbps UL Page 16 of 41 2012-11-30 PXS8 Hardware Interface Description 2.1 Key Features at a Glance 19 Feature Implementation GSM / GPRS / EGPRS features Data transfer GPRS: • Multislot Class 12 • Full PBCCH support • Mobile Station Class B • Coding Scheme 1 – 4 EGPRS: • Multislot Class 12 • EDGE E2 power class for 8 PSK • Downlink coding schemes – CS 1-4, MCS 1-9 • Uplink coding schemes – CS 1-4, MCS 1-9 • SRB loopback and test mode B • 8-bit, 11-bit RACH • PBCCH support • 1 phase/2 phase access procedures • Link adaptation and IR • NACC, extended UL TBF • Mobile Station Class B CSD: • V.110, RLP, non-transparent • 14.4kbps • USSD SMS Point-to-point MT and MO Cell broadcast Text and PDU mode GNSS Features Protocol NMEA Modes Standalone GPS Combined GPS + GLONASS Assisted GPS (resp. GPS + GLONASS) - Control plane - E911 - User plane - gpsOneXTRA™ General Power saving modes Software AT commands Hayes, 3GPP TS 27.007 and 27.005, and proprietary Cinterion Wireless Modules commands as well as provider specific CDMA commands SIM Application Toolkit SAT Release 99 Audio Audio speech codecs GSM: AMR, EFR, FR, HR 3GPP: AMR 3GPP2: EVRC, EVRC-B (4GV-NB), QCELP, AMR-NB Speakerphone operation, echo cancellation, noise suppression, 9 ringing tones, TTY support Software update Generic firmware update from host application over ASC0 or USB PXS8_HD_v03.000 Confidential / Preliminary Page 17 of 41 2012-11-30 PXS8 Hardware Interface Description 2.1 Key Features at a Glance 19 Feature Implementation Interfaces Module interface Surface mount device with solderable connection pads (SMT application interface). Land grid array (LGA) technology ensures high solder joint reliability and provides the possibility to use an optional module mounting socket. For more information on how to integrate SMT modules see also [4]. This application note comprises chapters on module mounting and application layout issues as well as on additional SMT application development equipment. Antenna 50Ohms. GSM/UMTS/CDMA main antenna, UMTS/CDMA diversity antenna, GNSS antenna (active/passive) USB USB 2.0 High Speed (480Mbit/s) device interface, Full Speed (12Mbit/s) compliant Serial interface ASC0: • 8-wire modem interface with status and control lines, unbalanced, asynchronous • Adjustable baud rates from 9,600bps up to 921,600bps • Supports RTS0/CTS0 hardware flow control • Multiplex ability according to GSM 07.10 Multiplexer Protocol UICC interface Supported chip cards: UICC/SIM/USIM 3V, 1.8V Status Signal line to indicate network connectivity state Audio 1 analog interface with microphone feeding 1 digital interface: PCM or I2S Power on/off, Reset Power on/off Switch-on by hardware signal IGT Switch-off by AT command (AT^SMSO) Automatic switch-off in case of critical temperature or voltage conditions Reset Orderly shutdown and reset by AT command Emergency-off Emergency-off by hardware signal EMERG_OFF if IGT is not active Special Features Phonebook SIM and phone TTY/CTM support Integrated CTM modem Antenna SAIC (Single Antenna Interference Cancellation) / DARP (Downlink Advanced Receiver Performance) Rx diversity (receiver type 3i - 16-QAM) Over-the-air provisioning Verizon specific OTASP (Over-the-Air Service Provisioning) and OTAPA (Over-the-Air Parameter Administration) Evaluation kit Evaluation module PXS8 module soldered onto a dedicated PCB that can be connected to an adapter in order to be mounted onto the DSB75. DSB75 DSB75 Development Support Board designed to test and type approve Cinterion Wireless Modules and provide a sample configuration for application engineering. A special adapter is required to connect the PXS8 evaluation module to the DSB75. PXS8_HD_v03.000 Confidential / Preliminary Page 18 of 41 2012-11-30 PXS8 Hardware Interface Description 2.2 PXS8 System Overview 19 2.2 PXS8 System Overview GNSS antenna GSM/UMTS/CDMA UMTS/CDMA main antenna diversity antenna Application GNSS active antenna supply, current limiter Power Supply SIM Card GSM/UMTS/CDMA UICC GNSS Host Application Controller Analog audio Power supply Digital audio PCM or I2S Codec LCI Low current indication Wakeup Power for Application (VEXT) Power Indication (PWR_IND) Serial ASC0 Host Wakeup USB Modem Interface Module RTC IGT, Emergency Off Net state/ status or PSU On/Off Application Figure 1: PXS8 system overview PXS8_HD_v03.000 Confidential / Preliminary Page 19 of 41 2012-11-30 PXS8 Hardware Interface Description 3 Application Interface 29 Application Interface PXS8 is equipped with an SMT application interface that connects to the external application. The host interface incorporates several sub-interfaces described in the following sections: • • • • • • • Operating modes - see Section 3.1 Power supply - see Section 3.2 Serial interface USB - see Section 3.3 Serial interface ASC0 - Section 3.4 UICC/SIM/USIM interface - see Section 3.5 Analog audio interface - see Section 3.6 Digital audio interface (PCM or I2S) - see Section 3.7 PXS8_HD_v03.000 Confidential / Preliminary Page 20 of 41 2012-11-30 PXS8 Hardware Interface Description 3.1 Operating Modes 29 3.1 Operating Modes The table below briefly summarizes the various operating modes referred to in the following chapters. Table 7: Overview of operating modes Mode Function Normal GSM / operation GPRS / UMTS / HSPA / CDMA SLEEP Power saving set automatically when no call is in progress and the USB connection is suspended by host or not present and no active communication via ASC0. GSM / GPRS / UMTS / HSPA / CDMA IDLE Power saving disabled (see [1]: AT^SCFG "MEopMode/ PwrSave",) or an USB connection not suspended, but no call in progress. GSM TALK/ GSM DATA Connection between two subscribers is in progress. Power consumption depends on the GSM network coverage and several connection settings (e.g. DTX off/on, FR/EFR/HR, hopping sequences and antenna connection). The following applies when power is to be measured in TALK_GSM mode: DTX off, FR and no frequency hopping. GPRS DATA GPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates and GPRS configuration (e.g. used multislot settings). EGPRS DATA EGPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates and EGPRS configuration (e.g. used multislot settings). UMTS TALK/ UMTS DATA UMTS data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate. HSPA DATA HSPA data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate. CDMA TALK/ CDMA DATA CDMA data transfer in progress. Power consumption depends on network settings and data transfer rate. Power Down Normal shutdown after sending the AT^SMSO command. Only a voltage regulator is active for powering the RTC. Software is not active. Interfaces are not accessible. Operating voltage (connected to BATT+) remains applied. Airplane mode Airplane mode shuts down the radio part of the module, causes the module to log off from the GSM/GPRS/CDMA network and disables all AT commands whose execution requires a radio connection. Airplane mode can be controlled by AT command (see [1]). PXS8_HD_v03.000 Confidential / Preliminary Page 21 of 41 2012-11-30 PXS8 Hardware Interface Description 3.2 Power Supply 29 3.2 Power Supply PXS8 needs to be connected to a power supply at the SMT application interface - 6 lines each BATT+ and GND. There are three separate voltage domains for BATT+: • BATT+_PA1 with 2 lines for the first power amplifier supply • BATT+_PA2 with 2 lines for the second power amplifier supply • BATT+ with 2 lines for the general power management. The main power supply from an external application has to be a single voltage source and has to be expanded to three sub paths (star structure). Capacitors should be placed as close as possible to the BATT+ pads. Figure 2 shows two sample circuits (minimum requirement and recommended alternative) for decoupling capacitors for BATT+. Module SMT interface BATT+ BATT+_PA1 BATT+_PA2 BATT+ Minimum requirement Decoupling capacitor e.g. 100…220µF Ultra-low ESR GND Module SMT interface BATT+ BATT+_PA1 BATT+_PA2 Recommended alternative BATT+ 3x Decoupling capacitors e.g. 47µF X5R MLCC GND Figure 2: Decoupling capacitor(s) for BATT+ The power supply of PXS8 must be able to provide the peak current during the uplink transmission. All key functions for supplying power to the device are handled by the power management IC. It provides the following features: • Stabilizes the supply voltages for the baseband using switching regulators and low drop linear voltage regulators. • Switches the module's power voltages for the power-up and -down procedures. • Delivers, across the VEXT line, a regulated voltage for an external application. This voltage is not available in Power-down mode and can be reduced via AT command to save power • SIM switch to provide SIM power supply. PXS8_HD_v03.000 Confidential / Preliminary Page 22 of 41 2012-11-30 PXS8 Hardware Interface Description 3.3 USB Interface 29 3.3 USB Interface PXS8 supports a USB 2.0 High Speed (480Mbit/s) device interface that is Full Speed (12Mbit/s) compliant. The USB interface is primarily intended for use as command and data interface and for downloading firmware. The external application is responsible for supplying the VUSB_IN line. This line is used for cable detection only. The USB part (driver and transceiver) is supplied by means of BATT+. This is because PXS8 is designed as a self-powered device compliant with the “Universal Serial Bus Specification Revision 2.0”1. Module SMT VREG (3V075) lin. reg. BATT+ GND USB part1) VBUS Detection only VUSB_IN RS DP DN RS Host wakeup USB_DP2) USB_DN2) RING0 WAKEUP 1) All serial (including RS) and pull-up resistors for data lines are implemented. If the USB interface is operated in High Speed mode (480MHz), it is recommended to take special care routing the data lines USB_DP and USB_DN. Application layout should in this case implement a differential impedance of 90Ohm for proper signal integrity. 2) Figure 3: USB circuit To properly connect the module's USB interface to the external application, a USB 2.0 compatible connector and cable or hardware design is required. 1. The specification is ready for download on http://www.usb.org/developers/docs/ PXS8_HD_v03.000 Confidential / Preliminary Page 23 of 41 2012-11-30 PXS8 Hardware Interface Description 3.4 Serial Interface ASC0 29 3.4 Serial Interface ASC0 PXS8 offers an 8-wire unbalanced, asynchronous modem interface ASC0 conforming to ITUT V.24 protocol DCE signalling. The electrical characteristics do not comply with ITU-T V.28. The significant levels are 0V (for low data bit or active state) and 1.8V (for high data bit or inactive state). PXS8 is designed for use as a DCE. Based on the conventions for DCE-DTE connections it communicates with the customer application (DTE) using the following signals: • Port TXD @ application sends data to the module’s TXD0 signal line • Port RXD @ application receives data from the module’s RXD0 signal line Figure 4: Serial interface ASC0 Features: • Includes the data lines TXD0 and RXD0, the status lines RTS0 and CTS0 and, in addition, the modem control lines DTR0, DSR0, DCD0 and RING0. • ASC0 is designed for controlling GSM/UMTS/CDMA voice calls, transferring data and for controlling the module with AT commands. • Full multiplexing capability allows the interface to be partitioned into virtual channels. • The RING0 signal serves to indicate incoming calls and other types of URCs (Unsolicited Result Code). It can also be used to send pulses to the host application, for example to wake up the application from power saving state. See [1] for details on how to configure the RING0 line by AT^SCFG. • Configured for 8 data bits, no parity and 1 stop bit. • ASC0 can be operated at fixed bit rates from 9600bps up to 921600bps. • Supports RTS0/CTS0 hardware flow control. • Wake up from SLEEP mode by RTS0 activation (high to low transition). Note. If the ASC0 serial interface is the application’s only interface, it is suggested to connect test points on the USB signal lines as a potential tracing possibility. PXS8_HD_v03.000 Confidential / Preliminary Page 24 of 41 2012-11-30 PXS8 Hardware Interface Description 3.4 Serial Interface ASC0 29 Table 8: DCE-DTE wiring of ASC0 V.24 circuit DCE DTE Line function Signal direction Line function Signal direction 103 TXD0 Input TXD Output 104 RXD0 Output RXD Input 105 RTS0 Input RTS Output 106 CTS0 Output CTS Input 108/2 DTR0 Input DTR Output 107 DSR0 Output DSR Input 109 DCD0 Output DCD Input 125 RING0 Output RING Input PXS8_HD_v03.000 Confidential / Preliminary Page 25 of 41 2012-11-30 PXS8 Hardware Interface Description 3.5 UICC/SIM/USIM Interface 29 3.5 UICC/SIM/USIM Interface PXS8 has an integrated UICC/SIM/USIM interface compatible with the 3GPP 31.102 and ETSI 102 221. This is wired to the host interface in order to be connected to an external SIM card holder. Five pads on the SMT application interface are reserved for the SIM interface. The UICC/SIM/USIM interface supports 3V and 1.8V SIM cards. The CCIN signal serves to detect whether a tray (with SIM card) is present in the card holder. Using the CCIN signal is mandatory for compliance with the GSM 11.11 recommendation if the mechanical design of the host application allows the user to remove the SIM card during operation. To take advantage of this feature, an appropriate SIM card detect switch is required on the card holder. For example, this is true for the model supplied by Molex, which has been tested to operate with PXS8 and is part of the Cinterion reference equipment submitted for type approval. See Chapter 9 for Molex ordering numbers. Table 9: Signals of the SIM interface (SMT application interface) Signal Description GND Ground connection for SIM. Optionally a separate SIM ground line using e.g., pad N11 may be used to improve EMC. CCCLK Chipcard clock CCVCC SIM supply voltage. CCIO Serial data line, input and output. CCRST Chipcard reset CCIN Input on the baseband processor for detecting a SIM card tray in the holder. If the SIM is removed during operation the SIM interface is shut down immediately to prevent destruction of the SIM. The CCIN signal is active low. The CCIN signal is mandatory for applications that allow the user to remove the SIM card during operation. The CCIN signal is solely intended for use with a SIM card. It must not be used for any other purposes. Failure to comply with this requirement may invalidate the type approval of PXS8. Note: No guarantee can be given, nor any liability accepted, if loss of data is encountered after removing the SIM card during operation. Also, no guarantee can be given for properly initializing any SIM card that the user inserts after having removed the SIM card during operation. In this case, the application must restart PXS8. PXS8_HD_v03.000 Confidential / Preliminary Page 26 of 41 2012-11-30 PXS8 Hardware Interface Description 3.5 UICC/SIM/USIM Interface 29 open: Card removed closed: Card inserted Module SMT application interface CCIN CCRST 1n SIM / UICC CCCLK GND CCIO CCVCC 220n Figure 5: UICC/SIM/USIM interface The total cable length between the SMT application interface pads on PXS8 and the pads of the external SIM card holder must not exceed 100mm in order to meet the specifications of 3GPP TS 51.010-1 and to satisfy the requirements of EMC compliance. To avoid possible cross-talk from the CCCLK signal to the CCIO signal be careful that both lines are not placed closely next to each other. A useful approach is using the GND line to shield the CCIO line from the CCCLK line. PXS8_HD_v03.000 Confidential / Preliminary Page 27 of 41 2012-11-30 PXS8 Hardware Interface Description 3.6 Analog Audio Interface 29 3.6 Analog Audio Interface PXS8 has an analog audio interface with a balanced analog microphone input and a balanced analog earpiece output. A supply voltage and an analog ground connection are provided at dedicated lines. PXS8 offers eight audio modes which can be selected with the AT^SNFS command. The electrical characteristics of the voiceband part vary with the audio mode. For example, sending and receiving amplification, sidetone paths, noise suppression etc. depend on the selected mode and can in parts be altered with AT commands (except for mode 1). When shipped from factory, all audio parameters of PXS8 are set to audio mode 1. This is the default configuration optimised for the Votronic HH-SI-30.3/V1.1/0 handset and used for type approving the Cinterion Wireless Modules reference configuration. Audio mode 1 has fix parameters which cannot be modified. To adjust the settings of the Votronic handset simply change to another audio mode. 3.7 Digital Audio Interface PXS8 supports a digital audio interface that can be employed either as pulse code modulation or as inter IC sound interface. Operation of these interface variants is mutually exclusive. PXS8_HD_v03.000 Confidential / Preliminary Page 28 of 41 2012-11-30 PXS8 Hardware Interface Description 4 GNSS Receiver 29 GNSS Receiver PXS8 integrates a GNSS receiver that offers the full performance of GPS/GLONASS technology. The GNSS receiver is able to continuously track all satellites in view, thus providing accurate satellite position data. The integrated GNSS receiver supports the NMEA protocol via USB or ASC0 interface1. NMEA is a combined electrical and data specification for communication between various (marine) electronic devices including GNSS receivers. It has been defined and controlled by the USbased National Marine Electronics Association. For more information on the NMEA Standard please refer to http://www.nmea.org. Depending on the receiver’s knowledge of last position, current time and ephemeris data, the receiver’s startup time (i.e., TTFF = Time-To-First-Fix) may vary: If the receiver has no knowledge of its last position or time, a startup takes considerably longer than if the receiver has still knowledge of its last position, time and almanac or has still access to valid ephimeris data and the precise time. By default, the GNSS receiver is switched off. It has to be switched on and configured using AT commands. For more information on how to control the GNSS interface via the AT command AT^SGPSC see [1]. 1. Using the serial ASC0 interface NMEA data is transmitted at a fixed speed of 115200bps. PXS8_HD_v03.000 Confidential / Preliminary Page 29 of 41 2012-11-30 PXS8 Hardware Interface Description 5 Antenna Interfaces 33 Antenna Interfaces 5.1 GSM/UMTS/CDMA Antenna Interface The PXS8 GSM/UMTS/CDMA antenna interface comprises a main GSM/UMTS/CDMA antenna as well as an optional UMTS/CDMA Rx diversity antenna to improve signal reliability and quality1. The interface has an impedance of 50. PXS8 is capable of sustaining a total mismatch at the antenna interface without any damage, even when transmitting at maximum RF power. The external antenna must be matched properly to achieve best performance regarding radiated power, modulation accuracy and harmonic suppression. Matching networks are not included on the PXS8 PCB and should be placed in the host application, if the antenna does not have an impedance of 50. Regarding the return loss PXS8 provides the following values in the active band: Table 10: Return loss in the active band State of module Return loss of module Recommended return loss of application Receive > 8dB > 12dB Transmit not applicable > 12dB Idle < 5dB not applicable 1. By delivery default the optional UMTS/CDMA Rx diversity antenna is configured as available for the module. To avoid negative side effects and performance degradation it is recommended to disable the diversity antenna path if - the host application does not support a diversity antenna - the host application includes a diversity antenna - but a 3G network simulator is used for development and performance tests. Please refer to [1] for details on how to configure antenna settings. PXS8_HD_v03.000 Confidential / Preliminary Page 30 of 41 2012-11-30 PXS8 Hardware Interface Description 5.1 GSM/UMTS/CDMA Antenna Interface 33 5.1.1 Antenna Installation The antenna is connected by soldering the antenna pads and their neighboring ground pads directly to the application’s PCB. The distance between the antenna pads and their neighboring GND pads has been optimized for best possible impedance. To prevent mismatch, special attention should be paid to these pads on the application’ PCB. The wiring of the antenna connection, starting from the antenna pad to the application’s antenna should result in a 50 line impedance. Line width and distance to the GND plane need to be optimized with regard to the PCB’s layer stack. To prevent receiver desensitization due to interferences generated by fast transients like high speed clocks on the external application PCB, it is recommended to realize the antenna connection line using embedded Stripline rather than Micro-Stripline technology. For type approval purposes, the use of a 50 coaxial antenna connector (U.FL-R-SMT) might be necessary. In this case the U.FL-R-SMT connector should be placed as close as possible to PXS8‘s antenna pad. PXS8_HD_v03.000 Confidential / Preliminary Page 31 of 41 2012-11-30 PXS8 Hardware Interface Description 5.2 GNSS Antenna Interface 33 5.2 GNSS Antenna Interface In addition to the RF antenna interface PXS8 also has a GNSS antenna interface. The GNSS antenna installation and connector are the same as for the RF antenna interface (see Section 5.1.1). For use with GPS and GLONASS it is recommended to use a GPS and GLONASS capable antenna. It is possible to connect active or passive GNSSS antennas. In either case they must have 50 Ohm impedance. The simultaneous operation of GSM/CDMA and GNSS has been implemented. PXS8 provides the supply voltage VGNSS for the GNSS active antenna (3.05V). It has to be enabled by software when the GNSS receiver shall becomes active, otherwise VGNSS should be off (power saving). VGNSS is not short circuit protected. This will have to be provided for by an external application. The DC voltage should be fed back via ANT_GNSS_DC for coupling into the GNSS antenna path. Figure 6 shows the flexibility in realizing the power supply for an active GNSS antenna by giving two sample circuits realizing the supply voltage for an active GNSS antenna - one with short circuit protection and one with an external LDO employed. Module SMT interface typ 3.05V max. 300mA Not short circuit protected! VGNSS Short circuit protection (Imax=50mA) 47pF ANT_GNSS_DC Active GNSS antenna (Optional) 10k 1uF 10nH ESD protection ANT_GNSS 2p2 Supply with short circuit protection External voltage Module SMT interface Enable VGNSS 47pF LDO ANT_GNSS_DC Active GNSS antenna (Optional) 10k 10nH 1uF ESD protection ANT_GNSS 2p2 Supply with external LDO employed Figure 6: Supply voltage for active GNSS antenna PXS8_HD_v03.000 Confidential / Preliminary Page 32 of 41 2012-11-30 PXS8 Hardware Interface Description 5.2 GNSS Antenna Interface 33 Figure 7 shows sample circuits realizing ESD protection for a passive GNSS antenna. Module SMT interface VGNSS 47pF Not used ANT_GNSS_DC (Optional) 0R ESD protection Passive GNSS antenna 10nH ANT_GNSS 2p2 Figure 7: ESD protection for passive GNSS antenna PXS8_HD_v03.000 Confidential / Preliminary Page 33 of 41 2012-11-30 PXS8 Hardware Interface Description 6 Mechanics, Mounting and Packaging 35 Mechanics, Mounting and Packaging 6.1 Mechanical Dimensions of PXS8 Figure 8 shows a 3D view1 of PXS8 and provides an overview of the board's mechanical dimensions. For further details see Figure 9. Length: 33mm Width: 29mm Height: 2mm Top view Bottom view Figure 8: PXS8 – top and bottomview 1. The coloring of the 3D view does not reflect the module’s real color. PXS8_HD_v03.000 Confidential / Preliminary Page 34 of 41 2012-11-30 PXS8 Hardware Interface Description 6.1 Mechanical Dimensions of PXS8 35 Position marker Internal use; Not to be soldered Figure 9: Dimensions of PXS8 (all dimensions in mm) PXS8_HD_v03.000 Confidential / Preliminary Page 35 of 41 2012-11-30 PXS8 Hardware Interface Description 7 Sample Application 37 Sample Application Figure 10 shows a typical example of how to integrate an PXS8 module with an application. The audio interface demonstrates the balanced connection of microphone and earpiece. This solution is particularly well suited for internal transducers. The PWR_IND line is an open collector that needs an external pull-up resistor which connects to the voltage supply VCC µC of the microcontroller. Low state of the open collector pulls the PWR_IND signal low and indicates that the PXS8 module is active, high level notifies the Power-down mode. If the module is in Power-down mode avoid current flowing from any other source into the module circuit, for example reverse current from high state external control lines. Therefore, the controlling application must be designed to prevent reverse flow. If an external level controller is required, this can be done by using for example a 5V I/O tolerant buffer/driver like a "74AVC4T245" with OE (Output Enable) controlled by PWR_IND. While developing SMT applications it is strongly recommended to provide test points for certain signals resp. lines to and from the module - for debug and/or test purposes. The SMT application should allow for an easy access to these signals. For details on how to implement test points see [4]. The EMC measures are best practice recommendations. In fact, an adequate EMC strategy for an individual application is very much determined by the overall layout and, especially, the position of components. Disclaimer: No warranty, either stated or implied, is provided on the sample schematic diagram shown in Figure 10 and the information detailed in this section. As functionality and compliance with national regulations depend to a great amount on the used electronic components and the individual application layout manufacturers are required to ensure adequate design and operating safeguards for their products using PXS8 modules. PXS8_HD_v03.000 Confidential / Preliminary Page 36 of 41 2012-11-30 PXS8 Hardware Interface Description 7 Sample Application 37 PXS8 Sample Application Current limiter <60mA ANT_MAIN VGNSS ANT_DRX ANT_GNSS BC847 47k 47k EMERG_RST BC847 VCC µC 100k PWR_IND 100µF ...220µF ultra low ESR 10µF VDD (1.8V) VEXT (1.8V) VCC µC V CCA OE 470R VCCB 1k 1µF FB* 1µF FB* Level Controller 1k FB* CCIN CCVCC CCRST EPP CCCLK AGND 220nF 1nF Figure 10: PXS8 sample application PXS8_HD_v03.000 Confidential / Preliminary Page 37 of 41 2012-11-30 PXS8 Hardware Interface Description 8 Reference Approval 39 Reference Approval 8.1 Reference Equipment for Type Approval The Cinterion Wireless Modules reference setup submitted to type approve PXS8 is shown in Figure 11. The module (i.e., the evaluation module) is connected to the DSB75 by means of a flex cable and a special DSB75 adapter. The GMS/UMTS/CDMA/GNSS test equipment is connected via edge mount SMA connectors soldered to the module’s antenna pads. For ESD tests and evaluation purposes, it is also possible connect the module to the GSM/ UMTS/CDMA/GNSS test equipment through an SMA-to-Hirose-U.FL antenna cable and the SMA antenna connectors of the DSB75 adapter. A further option is to mount the evaluation module directly onto the DSB75 adapter’s 80-pin board-to-board connector and to connect the test equipment as shown below. A udio test equipm ent V otronic handset an alo ga ud io D etail: If u sin Edge m ount SM A connectors m anually soldered to antenna pads S tandard 80 polig Flex PX S 8 evaluation m odule P X S8 U ranus evaluation m odule USB SM GNSS test equipm ent At H ir os COM1 (A S C 0) D SB 75 adapter eU .F L ca b le GNSS A N T3 A N T2 G S M /U M TS/ CDMA test equipm ent U M TS /C D M A D rx A N T1 P ow er A ud io GND G S M /U M TS /C D M A M ain A udio D S B 75 USB cable PC Pow er supply R S 232 cable Figure 11: Reference equipment for type approval PXS8_HD_v03.000 Confidential / Preliminary Page 38 of 41 2012-11-30 PXS8 Hardware Interface Description 8.2 Compliance with FCC and IC Rules and Regulations 39 8.2 Compliance with FCC and IC Rules and Regulations The Equipment Authorization Certification for the Cinterion Wireless Modules reference application described in Section 8.1 will be registered under the following identifiers: FCC Identifier QIPPXS8 Industry Canada Certification Number: 7830A-PXS8 Granted to Cinterion Wireless Modules GmbH Manufacturers of mobile or fixed devices incorporating PXS8 modules are authorized to use the FCC Grants and Industry Canada Certificates of the PXS8 modules for their own final products according to the conditions referenced in these documents. In this case, the FCC label of the module shall be visible from the outside, or the host device shall bear a second label stating "Contains FCC ID QIPPXS8" and accordingly “Contains IC 7830A-PXS8“. The integration is limited to fixed or mobile categorised host devices, where a separation distance between the antenna and any person of min. 20cm can be assured during normal operating conditions. For mobile and fixed operation configurations the antenna gain, including cable loss, must not exceed the limits 3.92 dBi (850 MHz) and 2.51 dBi (1900 MHz). IMPORTANT: Manufacturers of portable applications incorporating PXS8 modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable mobile. This is mandatory to meet the SAR requirements for portable mobiles (see Section 1.3.1 for detail). Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This Class B digital apparatus complies with Canadian ICES-003. PXS8_HD_v03.000 Confidential / Preliminary Page 39 of 41 2012-11-30 PXS8 Hardware Interface Description 9 Appendix 41 Appendix 9.1 List of Parts and Accessories Table 11: List of parts and accessories Description Supplier Ordering information PXS8 Cinterion Standard module Cinterion Wireless Modules IMEI: Ordering number: L30960-N2600-A300 PXS8 Evaluation Module Cinterion Ordering number: L30960-N2601-A300 DSB75 Support Box Cinterion Ordering number: L36880-N8811-A100 DSB75 adapter for mounting Cinterion the PXS8 evaluation module Ordering number: L30960-N2301-A100 Votronic Handset VOTRONIC Votronic HH-SI-30.3/V1.1/0 VOTRONIC Entwicklungs- und Produktionsgesellschaft für elektronische Geräte mbH Saarbrücker Str. 8 66386 St. Ingbert Germany Phone: +49-(0)6 89 4 / 92 55-0 Fax: +49-(0)6 89 4 / 92 55-88 Email: contact@votronic.com SIM card holder incl. push button ejector and slide-in tray Molex Ordering numbers: 91228 91236 Sales contacts are listed in Table 12. U.FL antenna connector Hirose or Molex Sales contacts are listed in Table 12 and Table 13. PXS8_HD_v03.000 Confidential / Preliminary Page 40 of 41 2012-11-30 PXS8 Hardware Interface Description 9.1 List of Parts and Accessories 41 Table 12: Molex sales contacts (subject to change) Molex For further information please click: http://www.molex.com Molex Deutschland GmbH Otto-Hahn-Str. 1b 69190 Walldorf Germany Phone: +49-6227-3091-0 Fax: +49-6227-3091-8100 Email: mxgermany@molex.com American Headquarters Lisle, Illinois 60532 U.S.A. Phone: +1-800-78MOLEX Fax: +1-630-969-1352 Molex China Distributors Beijing, Room 1311, Tower B, COFCO Plaza No. 8, Jian Guo Men Nei Street, 100005 Beijing P.R. China Phone: +86-10-6526-9628 Fax: +86-10-6526-9730 Molex Singapore Pte. Ltd. 110, International Road Jurong Town, Singapore 629174 Molex Japan Co. Ltd. 1-5-4 Fukami-Higashi, Yamato-City, Kanagawa, 242-8585 Japan Phone: +65-6-268-6868 Fax: +65-6-265-6044 Phone: +81-46-265-2325 Fax: +81-46-265-2365 Table 13: Hirose sales contacts (subject to change) Hirose Ltd. For further information please click: http://www.hirose.com Hirose Electric (U.S.A.) Inc 2688 Westhills Court Simi Valley, CA 93065 U.S.A. Phone: +1-805-522-7958 Fax: +1-805-522-3217 Hirose Electric Europe B.V. German Branch: Herzog-Carl-Strasse 4 73760 Ostfildern Germany Phone: +49-711-456002-1 Fax: +49-711-456002-299 Email: info@hirose.de Hirose Electric Europe B.V. UK Branch: First Floor, St. Andrews House, Caldecotte Lake Business Park, Milton Keynes MK7 8LE Great Britain Hirose Electric Co., Ltd. 5-23, Osaki 5 Chome, Shinagawa-Ku Tokyo 141 Japan Hirose Electric Europe B.V. Hogehillweg 8 1101 CC Amsterdam Z-O Netherlands Phone: +44-1908-369060 Fax: +44-1908-369078 Phone: +81-03-3491-9741 Fax: +81-03-3493-2933 Phone: +31-20-6557-460 Fax: +31-20-6557-469 PXS8_HD_v03.000 Confidential / Preliminary Page 41 of 41 2012-11-30
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : chinrich Create Date : 2012:11:30 16:07:09Z Modify Date : 2012:11:30 16:26:34+01:00 XMP Toolkit : Adobe XMP Core 4.2.2-c063 53.352624, 2008/07/30-18:12:18 Format : application/pdf Title : hid.book Creator : chinrich Creator Tool : FrameMaker 9.0 Metadata Date : 2012:11:30 16:26:34+01:00 Producer : Acrobat Distiller 9.5.2 (Windows) Document ID : uuid:0a14585d-9fde-4b2d-9378-dba386e54728 Instance ID : uuid:553fae7b-40e2-4dab-8d9e-8c5577bccc50 Page Mode : UseOutlines Page Count : 41EXIF Metadata provided by EXIF.tools