THALES DIS AlS Deutschland PXS8 GSM/GPRS/EDGE/CDMA/UMTS/HSPA Module User Manual hid

Gemalto M2M GmbH GSM/GPRS/EDGE/CDMA/UMTS/HSPA Module hid

Contents

integration manual

Download: THALES DIS AlS Deutschland PXS8 GSM/GPRS/EDGE/CDMA/UMTS/HSPA Module User Manual hid
Mirror Download [FCC.gov]THALES DIS AlS Deutschland PXS8 GSM/GPRS/EDGE/CDMA/UMTS/HSPA Module User Manual hid
Document ID1734526
Application IDTjbcnU3fZ7nBoLcPvUivug==
Document Descriptionintegration manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize50.85kB (635564 bits)
Date Submitted2012-07-02 00:00:00
Date Available2012-07-31 00:00:00
Creation Date2012-06-27 15:05:25
Producing SoftwareAcrobat Distiller 9.5.1 (Windows)
Document Lastmod2012-06-27 15:11:14
Document Titlehid.book
Document CreatorFrameMaker 9.0
Document Author: chinrich

PXS8
Version:
DocId:
00.110a
PXS8_HIO_v00.110a
Hardware Interface Overview

PXS8 Hardware Interface Overview
Document Name:
PXS8 Hardware Interface Overview
Version:
00.110a
Date:
2012-06-27
DocId:
PXS8_HIO_v00.110a
Status
Confidential / Preliminary

GENERAL NOTE
THE USE OF THE PRODUCT INCLUDING THE SOFTWARE AND DOCUMENTATION (THE "PRODUCT") IS SUBJECT TO THE RELEASE NOTE PROVIDED TOGETHER WITH PRODUCT. IN ANY
EVENT THE PROVISIONS OF THE RELEASE NOTE SHALL PREVAIL. THIS DOCUMENT CONTAINS INFORMATION ON CINTERION PRODUCTS. THE SPECIFICATIONS IN THIS DOCUMENT
ARE SUBJECT TO CHANGE AT CINTERION'S DISCRETION. CINTERION WIRELESS MODULES
GMBH GRANTS A NON-EXCLUSIVE RIGHT TO USE THE PRODUCT. THE RECIPIENT SHALL NOT
TRANSFER, COPY, MODIFY, TRANSLATE, REVERSE ENGINEER, CREATE DERIVATIVE WORKS;
DISASSEMBLE OR DECOMPILE THE PRODUCT OR OTHERWISE USE THE PRODUCT EXCEPT
AS SPECIFICALLY AUTHORIZED. THE PRODUCT AND THIS DOCUMENT ARE PROVIDED ON AN
"AS IS" BASIS ONLY AND MAY CONTAIN DEFICIENCIES OR INADEQUACIES. TO THE MAXIMUM
EXTENT PERMITTED BY APPLICABLE LAW, CINTERION WIRELESS MODULES GMBH DISCLAIMS ALL WARRANTIES AND LIABILITIES. THE RECIPIENT UNDERTAKES FOR AN UNLIMITED
PERIOD OF TIME TO OBSERVE SECRECY REGARDING ANY INFORMATION AND DATA PROVIDED TO HIM IN THE CONTEXT OF THE DELIVERY OF THE PRODUCT. THIS GENERAL NOTE
SHALL BE GOVERNED AND CONSTRUED ACCORDING TO GERMAN LAW.
Copyright
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will
be held liable for payment of damages. All rights created by patent grant or registration of a utility model
or design patent are reserved.
Copyright © 2012, Cinterion Wireless Modules GmbH
Trademark Notice
Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the
United States and/or other countries. CDMA2000 is a registered certification mark of the Telecommunications Industry Association. All other registered trademarks or trademarks mentioned in this document
are property of their respective owners.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 2 of 41
2012-06-27
PXS8 Hardware Interface Overview
Contents
41

Contents
Introduction ................................................................................................................. 6
1.1
Related Documents ........................................................................................... 6
1.2
Terms and Abbreviations ................................................................................... 6
1.3
Regulatory and Type Approval Information ..................................................... 10
1.3.1 Directives and Standards.................................................................... 10
1.3.2 SAR requirements specific to portable mobiles .................................. 13
1.3.3 SELV Requirements ........................................................................... 14
1.3.4 Safety Precautions.............................................................................. 14
Product Concept ....................................................................................................... 16
2.1
Key Features at a Glance ................................................................................ 16
2.2
PXS8 System Overview................................................................................... 19
Application Interface................................................................................................. 20
3.1
Operating Modes ............................................................................................. 21
3.2
Power Supply................................................................................................... 22
3.3
USB Interface................................................................................................... 23
3.4
Serial Interface ASC0 ...................................................................................... 24
3.5
UICC/SIM/USIM Interface................................................................................ 26
3.6
Analog Audio Interface..................................................................................... 28
3.7
Digital Audio Interface...................................................................................... 28
GPS Receiver............................................................................................................. 29
Antenna Interfaces.................................................................................................... 30
5.1
GSM/UMTS/CDMA Antenna Interface............................................................. 30
5.1.1 Antenna Installation ............................................................................ 31
5.2
GPS Antenna Interface .................................................................................... 32
Mechanics, Mounting and Packaging ..................................................................... 34
6.1
Mechanical Dimensions of PXS8..................................................................... 34
Sample Application................................................................................................... 36
Reference Approval .................................................................................................. 38
8.1
Reference Equipment for Type Approval ......................................................... 38
8.2
Compliance with FCC and IC Rules and Regulations ..................................... 39
Appendix.................................................................................................................... 40
9.1
List of Parts and Accessories........................................................................... 40
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 3 of 41
2012-06-27
PXS8 Hardware Interface Overview
Tables
41

Tables
Table 1:
Table 2:
Table 3:
Table 4:
Table 5:
Table 6:
Table 7:
Table 8:
Table 9:
Table 10:
Table 11:
Table 12:
Table 13:
Directives .......................................................................................................
Standards of North American type approval ..................................................
Standards of European type approval............................................................
Requirements of quality .................................................................................
Standards of the Ministry of Information Industry of the
People’s Republic of China ............................................................................
Toxic or hazardous substances or elements with defined concentration
limits ...............................................................................................................
Overview of operating modes ........................................................................
DCE-DTE wiring of ASC0 ..............................................................................
Signals of the SIM interface (SMT application interface) ...............................
Return loss in the active band........................................................................
List of parts and accessories..........................................................................
Molex sales contacts (subject to change) ......................................................
Hirose sales contacts (subject to change) .....................................................
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 4 of 41
10
10
10
11
11
12
21
25
26
30
40
41
41
2012-06-27
PXS8 Hardware Interface Overview
Figures
41

Figures
Figure 1:
Figure 2:
Figure 3:
Figure 4:
Figure 5:
Figure 6:
Figure 7:
Figure 8:
Figure 9:
Figure 10:
Figure 11:
PXS8 system overview ..................................................................................
Decoupling capacitor(s) for BATT+................................................................
USB circuit .....................................................................................................
Serial interface ASC0.....................................................................................
UICC/SIM/USIM interface ..............................................................................
Supply voltage for active GPS antenna .........................................................
ESD protection for passive GPS antenna ......................................................
PXS8 – top and bottomview...........................................................................
Dimensions of PXS8 (all dimensions in mm) .................................................
PXS8 sample application ...............................................................................
Reference equipment for type approval .........................................................
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 5 of 41
19
22
23
24
27
32
33
34
35
37
38
2012-06-27
PXS8 Hardware Interface Overview
1 Introduction
15

Introduction
The document1 describes the hardware of the PXS8 module, designed to connect to a cellular
device application and the air interface. It helps you quickly retrieve interface specifications,
electrical and mechanical details and information on the requirements to be considered for integrating further components.
1.1
[1]
[2]
[3]
[4]
Related Documents
PXS8 AT Command Set
PXS8 Release Notes
DSB75 Support Box - Evaluation Kit for Cinterion Wireless Modules
Application Note 48: SMT Module Integration
1.2
Terms and Abbreviations
Abbreviation
Description
AGPS
Assisted GPS
ANSI
American National Standards Institute
AMR
Adaptive Multirate
ARP
Antenna Reference Point
BB
Baseband
BC
Band Class
BEP
Bit Error Probability
BTS
Base Transceiver Station
CB or CBM
Cell Broadcast Message
CDMA
Code Division Multiple Access
CE
Conformité Européene (European Conformity)
CS
Coding Scheme
CS
Circuit Switched
CSD
Circuit Switched Data
CTM
Cellular Text Modem
DAC
Digital-to-Analog Converter
DCS
Digital Cellular System
DL
Download
1.
The document is effective only if listed in the appropriate Release Notes as part of the technical
documentation delivered with your Cinterion Wireless Modules product.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 6 of 41
2012-06-27
PXS8 Hardware Interface Overview
1.2 Terms and Abbreviations
15
Abbreviation
Description
DRX
Discontinuous Reception
DSB
Development Support Board
DSP
Digital Signal Processor
DTMF
Dual Tone Multi Frequency
DTX
Discontinuous Transmission
EDGE
Enhanced Data rates for GSM Evolution
EFR
Enhanced Full Rate
EGSM
Extended GSM
EMC
Electromagnetic Compatibility
ERP
Effective Radiated Power
ESD
Electrostatic Discharge
ETS
European Telecommunication Standard
ETSI
European Telecommunications Standards Institute
EVRC
Enhanced Variable Rate Codec
FCC
Federal Communications Commission (U.S.)
FDD
Frequency Division Duplex
FDMA
Frequency Division Multiple Access
FL
Forward Link
FR
Full Rate
GPRS
General Packet Radio Service
GPS
Global Positioning System
GSM
Global Standard for Mobile Communications
HiZ
High Impedance
HSDPA
High Speed Downlink Packet Access
HR
Half Rate
I/O
Input/Output
IF
Intermediate Frequency
IMEI
International Mobile Equipment Identity
ISO
International Standards Organization
ITU
International Telecommunications Union
kbps
kbits per second
LED
Light Emitting Diode
LGA
Land Grid Array
MBB
Moisture barrier bag
Mbps
Mbits per second
MCS
Modulation and Coding Scheme
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 7 of 41

2012-06-27
PXS8 Hardware Interface Overview
1.2 Terms and Abbreviations
15

Abbreviation
Description
MO
Mobile Originated
MS
Mobile Station, also referred to as TE
MSL
Moisture Sensitivity Level
MT
Mobile Terminated
NB
Narrow Band
NMEA
National Marine Electronics Association
NTC
Negative Temperature Coefficient
PBCCH
Packet Switched Broadcast Control Channel
PCB
Printed Circuit Board
PCL
Power Control Level
PCM
Pulse Code Modulation
PCS
Personal Communication System, also referred to as GSM 1900
PD
Pull Down resistor (appr. 100k)
PDU
Protocol Data Unit
PS
Packet Switched
PSK
Phase Shift Keying
PU
Pull Up resistor (appr. 100k)
QAM
Quadrature Amplitude Modulation
R&TTE
Radio and Telecommunication Terminal Equipment
RF
Radio Frequency
RL
Reverse Link
ROPR
Radio Output Power Reduction
RTC
Real Time Clock
Rx
Receive Direction
SAR
Specific Absorption Rate
SELV
Safety Extra Low Voltage
SIM
Subscriber Identification Module
SLIC
Subscriber Line Interface Circuit
SMPL
Sudden Momentary Power Loss
SMD
Surface Mount Device
SMS
Short Message Service
SMT
Surface Mount Technology
SNR
Signal-to-Noise Ratio
SRAM
Static Random Access Memory
SRB
Signalling Radio Bearer
SUPL
Secure User Plane Location
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 8 of 41
2012-06-27
PXS8 Hardware Interface Overview
1.2 Terms and Abbreviations
15
Abbreviation
Description
TDMA
Time Division Multiple Access
TE
Terminal Equipment
TPC
Transmit Power Control
TS
Technical Specification
TTFF
Time To First Fix
Tx
Transmit Direction
UL
Upload
UMTS
Universal Mobile Telecommunications System
URC
Unsolicited Result Code
USB
Universal Serial Bus
UICC
USIM Integrated Circuit Card
USIM
UMTS Subscriber Identification Module
WCDMA
Wideband Code Division Multiple Access
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 9 of 41

2012-06-27
PXS8 Hardware Interface Overview
1.3 Regulatory and Type Approval Information
15
1.3
Regulatory and Type Approval Information
1.3.1
Directives and Standards

PXS8 has been designed to comply with the directives and standards listed below.
It is the responsibility of the application manufacturer to ensure compliance of the final product
with all provisions of the applicable directives and standards as well as with the technical specifications provided in the "PXS8 Hardware Interface Description".1
Table 1: Directives
99/05/EC
Directive of the European Parliament and of the council of 9 March 1999 on
radio equipment and telecommunications terminal equipment and the
mutual recognition of their conformity (in short referred to as R&TTE Directive 1999/5/EC).
The product is labeled with the CE conformity mark
2002/95/EC
Directive of the European Parliament and of the Council of
27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(RoHS)
Table 2: Standards of North American type approval
CFR Title 47
Code of Federal Regulations, Part 22, Part 24 and Part 27; US Equipment
Authorization FCC
OET Bulletin 65
(Edition 97-01)
Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields
UL 60 950-1
Product Safety Certification (Safety requirements)
NAPRD.03 V5.11
Overview of PCS Type certification review board Mobile Equipment Type
Certification and IMEI control
PCS Type Certification Review board (PTCRB)
RSS132, RSS133,
RSS139
Canadian Standard
Table 3: Standards of European type approval
3GPP TS 51.010-1
Digital cellular telecommunications system (Release 7); Mobile Station
(MS) conformance specification;
ETSI EN 301 511 V9.0.2 Global System for Mobile communications (GSM); Harmonized standard for
mobile stations in the GSM 900 and DCS 1800 bands covering essential
requirements under article 3.2 of the R&TTE directive (1999/5/EC)
GCF-CC V3.45
Global Certification Forum - Certification Criteria
ETSI EN 301 489-01
V1.8.1
Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services;
Part 1: Common Technical Requirements
1.
Manufacturers of applications which can be used in the US shall ensure that their applications have a
PTCRB approval. For this purpose they can refer to the PTCRB approval of the respective module.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 10 of 41
2012-06-27
PXS8 Hardware Interface Overview
1.3 Regulatory and Type Approval Information
15

Table 3: Standards of European type approval
ETSI EN 301 489-03
V1.4.1
Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services;
Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz
ETSI EN 301 489-07
V1.3.1
Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services;
Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS)
ETSI EN 301 489-24
V1.4.1
Electromagnetic Compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services;
Part 24: Specific conditions for IMT-2000 CDMA Direct Spread (UTRA) for
Mobile and portable (UE) radio and ancillary equipment
ETSI EN 301 908-01
V4.2.1
Electromagnetic compatibility and Radio spectrum Matters (ERM); Base
Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation cellular networks; Part 1: Harmonized EN for IMT-2000, introduction and common requirements of article 3.2 of the R&TTE Directive
ETSI EN 301 908-02
V4.2.1
Electromagnetic compatibility and Radio spectrum Matters (ERM); Base
Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation cellular networks; Part 2: Harmonized EN for IMT-2000, CDMA Direct Spread
(UTRA FDD) (UE) covering essential requirements of article 3.2 of the
R&TTE Directive
EN 300 440-02 V1.3.1
Electromagnetic compatibility and Radio spectrum Matters (ERM); Short
range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 2: Harmonized EN covering essential requirements of
article 3.2 of the R&TTE Directive
EN 62311:2008
Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz)
IEC/EN 60950-1:2006
Safety of information technology equipment
Table 4: Requirements of quality
IEC 60068
Environmental testing
DIN EN 60529
IP codes
Table 5: Standards of the Ministry of Information Industry of the People’s Republic of China
SJ/T 11363-2006
“Requirements for Concentration Limits for Certain Hazardous Substances
in Electronic Information Products” (2006-06).
SJ/T 11364-2006
“Marking for Control of Pollution Caused by Electronic
Information Products” (2006-06).
According to the “Chinese Administration on the Control of
Pollution caused by Electronic Information Products”
(ACPEIP) the EPUP, i.e., Environmental Protection Use
Period, of this product is 20 years as per the symbol
shown here, unless otherwise marked. The EPUP is valid only as long as
the product is operated within the operating limits described in the Cinterion
Hardware Interface Description.
Please see Table 6 for an overview of toxic or hazardous substances or elements that might be contained in product parts in concentrations above the
limits defined by SJ/T 11363-2006.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 11 of 41
2012-06-27
PXS8 Hardware Interface Overview
1.3 Regulatory and Type Approval Information
15

Table 6: Toxic or hazardous substances or elements with defined concentration limits
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 12 of 41
2012-06-27
PXS8 Hardware Interface Overview
1.3 Regulatory and Type Approval Information
15
1.3.2

SAR requirements specific to portable mobiles
Mobile phones, PDAs or other portable transmitters and receivers incorporating a GSM/CDMA
module must be in accordance with the guidelines for human exposure to radio frequency energy. This requires the Specific Absorption Rate (SAR) of portable PXS8 based applications to
be evaluated and approved for compliance with national and/or international regulations.
Since the SAR value varies significantly with the individual product design manufacturers are
advised to submit their product for approval if designed for portable use. For European and USmarkets the relevant directives are mentioned below. It is the responsibility of the manufacturer
of the final product to verify whether or not further standards, recommendations or directives
are in force outside these areas.
Products intended for sale on US markets
ES 59005/ANSI C95.1 Considerations for evaluation of human exposure to electromagnetic
fields (EMFs) from mobile telecommunication equipment (MTE) in the
frequency range 30MHz - 6GHz
Products intended for sale on European markets
EN 50360
Product standard to demonstrate the compliance of mobile phones with
the basic restrictions related to human exposure to electromagnetic
fields (300MHz - 3GHz)
IMPORTANT:
Manufacturers of portable applications based on PXS8 modules are required to have their final
product certified and apply for their own FCC Grant and Industry Canada Certificate related to
the specific portable mobile.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 13 of 41
2012-06-27
PXS8 Hardware Interface Overview
1.3 Regulatory and Type Approval Information
15
1.3.3

SELV Requirements
The power supply connected to the PXS8 module shall be in compliance with the SELV requirements defined in EN 60950-1.
1.3.4
Safety Precautions
The following safety precautions must be observed during all phases of the operation, usage,
service or repair of any cellular terminal or mobile incorporating PXS8. Manufacturers of the
cellular terminal are advised to convey the following safety information to users and operating
personnel and to incorporate these guidelines into all manuals supplied with the product. Failure to comply with these precautions violates safety standards of design, manufacture and intended use of the product. Cinterion Wireless Modules assumes no liability for customer’s
failure to comply with these precautions.
When in a hospital or other health care facility, observe the restrictions on the use of
mobiles. Switch the cellular terminal or mobile off, if instructed to do so by the guidelines posted in sensitive areas. Medical equipment may be sensitive to RF energy.
The operation of cardiac pacemakers, other implanted medical equipment and hearing
aids can be affected by interference from cellular terminals or mobiles placed close to
the device. If in doubt about potential danger, contact the physician or the manufacturer of the device to verify that the equipment is properly shielded. Pacemaker
patients are advised to keep their hand-held mobile away from the pacemaker, while
it is on.
Switch off the cellular terminal or mobile before boarding an aircraft. Make sure it cannot be switched on inadvertently. The operation of wireless appliances in an aircraft is
forbidden to prevent interference with communications systems. Failure to observe
these instructions may lead to the suspension or denial of cellular services to the
offender, legal action, or both.
Do not operate the cellular terminal or mobile in the presence of flammable gases or
fumes. Switch off the cellular terminal when you are near petrol stations, fuel depots,
chemical plants or where blasting operations are in progress. Operation of any electrical equipment in potentially explosive atmospheres can constitute a safety hazard.
Your cellular terminal or mobile receives and transmits radio frequency energy while
switched on. Remember that interference can occur if it is used close to TV sets,
radios, computers or inadequately shielded equipment. Follow any special regulations
and always switch off the cellular terminal or mobile wherever forbidden, or when you
suspect that it may cause interference or danger.
Road safety comes first! Do not use a hand-held cellular terminal or mobile when driving a vehicle, unless it is securely mounted in a holder for speakerphone operation.
Before making a call with a hand-held terminal or mobile, park the vehicle.
Speakerphones must be installed by qualified personnel. Faulty installation or operation can constitute a safety hazard.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 14 of 41
2012-06-27
PXS8 Hardware Interface Overview
1.3 Regulatory and Type Approval Information
15

IMPORTANT!
Cellular terminals or mobiles operate using radio signals and cellular networks.
Because of this, connection cannot be guaranteed at all times under all conditions.
Therefore, you should never rely solely upon any wireless device for essential communications, for example emergency calls.
Remember, in order to make or receive calls, the cellular terminal or mobile must be
switched on and in a service area with adequate cellular signal strength.
Some networks do not allow for emergency calls if certain network services or phone
features are in use (e.g. lock functions, fixed dialing etc.). You may need to deactivate
those features before you can make an emergency call.
Some networks require that a valid SIM card be properly inserted in the cellular terminal or mobile.
Bear in mind that exposure to excessive levels of noise can cause physical damage
to users! With regard to acoustic shock, the cellular application must be designed to
avoid unintentional increase of amplification, e.g. for a highly sensitive earpiece. A protection circuit should be implemented in the cellular application.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 15 of 41
2012-06-27
PXS8 Hardware Interface Overview
2 Product Concept
19
Product Concept
2.1
Key Features at a Glance
Feature

Implementation
General
Frequency bands
GSM/GPRS/EDGE: Quad band, 850/900/1800/1900MHz
UMTS/HSPA+: Five band, 800/850/900/1900/2100MHz
CDMA: Dual band (BC0/BC1), 800/1900MHz
GSM class
Small MS
Output power (according to Class 4 (+33dBm ±2dB) for EGSM850
Release 99)
Class 4 (+33dBm ±2dB) for EGSM900
Class 1 (+30dBm ±2dB) for GSM1800
Class 1 (+30dBm ±2dB) for GSM1900
Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK
Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK
Class 3 (+24dBm +1/-3dB) for UMTS 2100, WCDMA FDD BdI
Class 3 (+24dBm +1/-3dB) for UMTS 1900,WCDMA FDD BdII
Class 3 (+24dBm +1/-3dB) for UMTS 900, WCDMA FDD BdVIII
Class 3 (+24dBm +1/-3dB) for UMTS 850, WCDMA FDD BdV
Class 3 (+24dBm +1/-3dB) for UMTS 800, WCDMA FDD BdVI
Power supply
3.3V < VBATT+ < 4.2V
Operating temperature
(board temperature)
Normal operation: -30°C to +85°C
Restricted operation: -40°C to +95°C
Physical
Dimensions: 33mm x 29mm x 2mm
Weight: approx. 5g
RoHS
All hardware components fully compliant with EU RoHS Directive
CDMA features
3GPP2 CDMA2000
EV-DO Rev.A data rates:
FL max. 3.1Mbps, RL max. 1.8Mbps
1xRTT Advanced data rates:
FL max. 307.2kbps, RL max. 307.2kbps
HSPA features
3GPP Release 6, 7
DL 14.4Mbps, UL 5.7Mbps
UE CAT. 1-12 supported
Compressed mode (CM) supported according to 3GPP TS25.212
UMTS features
3GPP Release 4
PXS8_HIO_v00.110a
Confidential / Preliminary
PS data rate – 384 kbps DL / 384 kbps UL
CS data rate – 64 kbps DL / 64 kbps UL
Page 16 of 41
2012-06-27
PXS8 Hardware Interface Overview
2.1 Key Features at a Glance
19
Feature

Implementation
GSM / GPRS / EGPRS features
Data transfer
GPRS:
• Multislot Class 12
• Full PBCCH support
• Mobile Station Class B
• Coding Scheme 1 – 4
EGPRS:
• Multislot Class 12
• EDGE E2 power class for 8 PSK
• Downlink coding schemes – CS 1-4, MCS 1-9
• Uplink coding schemes – CS 1-4, MCS 1-9
• SRB loopback and test mode B
• 8-bit, 11-bit RACH
• PBCCH support
• 1 phase/2 phase access procedures
• Link adaptation and IR
• NACC, extended UL TBF
• Mobile Station Class B
CSD:
• V.110, RLP, non-transparent
• 14.4kbps
• USSD
SMS
Point-to-point MT and MO
Cell broadcast
Text and PDU mode
GPS Features
Protocol
NMEA
Modes
Standalone GPS
Assisted GPS
- Control plane - E911
- User plane - gpsOneXTRA™
General
Power saving modes
Software
AT commands
Hayes, 3GPP TS 27.007 and 27.005, and proprietary Cinterion Wireless
Modules commands as well as Verizon specific CDMA commands.
SIM Application Toolkit
SAT Release 99
Audio
Audio speech codecs
GSM: AMR, EFR, FR, HR
3GPP: AMR
3GPP2: EVRC, EVRC-B (4GV-NB), QCELP, AMR-NB
Speakerphone operation, echo cancellation, noise suppression, 9 ringing
tones, TTY support
Software update
Generic firmware update from host application over ASC0 or USB.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 17 of 41
2012-06-27
PXS8 Hardware Interface Overview
2.1 Key Features at a Glance
19
Feature

Implementation
Interfaces
Module interface
Surface mount device with solderable connection pads (SMT application
interface).
Land grid array (LGA) technology ensures high solder joint reliability and
provides the possibility to use an optional module mounting socket.
For more information on how to integrate SMT modules see also [4]. This
application note comprises chapters on module mounting and application
layout issues as well as on additional SMT application development
equipment.
Antenna
50Ohms. GSM/UMTS/CDMA main antenna, UMTS/CDMA diversity
antenna, GPS antenna (active/passive)
USB
USB 2.0 High Speed (480Mbit/s) device interface, Full Speed (12Mbit/s)
compliant
Serial interface
ASC0:
• 8-wire modem interface with status and control lines, unbalanced,
asynchronous
• Adjustable baud rates from 9,600bps up to 921,600bps
• Supports RTS0/CTS0 hardware flow control
• Multiplex ability according to GSM 07.10 Multiplexer Protocol
UICC interface
Supported chip cards: UICC/SIM/USIM 3V, 1.8V
Status
Signal line to indicate network connectivity state
Audio
1 analog interface with microphone feeding
1 digital interface: PCM or I2S
Power on/off, Reset
Power on/off
Switch-on by hardware signal IGT
Switch-off by AT command (AT^SMSO)
Automatic switch-off in case of critical temperature or voltage conditions
Reset
Orderly shutdown and reset by AT command
Emergency-off
Emergency-off by hardware signal EMERG_OFF if IGT is not active
Special Features
Phonebook
SIM and phone
TTY/CTM support
Integrated CTM modem
Antenna
SAIC (Single Antenna Interference Cancellation) / DARP (Downlink
Advanced Receiver Performance)
Rx diversity (receiver type 3i - 16-QAM)
Over-the-air provisioning
Verizon specific OTASP (Over-the-Air Service Provisioning) and OTAPA
(Over-the-Air Parameter Administration)
Evaluation kit
Evaluation module
PXS8 module soldered onto a dedicated PCB that can be connected to
an adapter in order to be mounted onto the DSB75.
DSB75
DSB75 Development Support Board designed to test and type approve
Cinterion Wireless Modules and provide a sample configuration for application engineering. A special adapter is required to connect the PXS8
evaluation module to the DSB75.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 18 of 41
2012-06-27

PXS8 Hardware Interface Overview
2.2 PXS8 System Overview
19
2.2
PXS8 System Overview
GPS antenna
GSM/UMTS/CDMA UMTS/CDMA
main antenna diversity antenna
Application
GPS
active antenna supply,
current limiter
Power
Supply
SIM
Card
GSM/UMTS/CDMA
UICC
GPS
Host Application
Controller
Analog
audio
Power
supply
Digital
audio
PCM or I2S
Codec
LCI
RTC
Low current
indication
Wakeup
Power for Application
(VEXT)
Power Indication
(PWR_IND)
Serial
ASC0
Host Wakeup
USB
Modem Interface
Module
or
IGT,
Emergency Off
Net state/
status
PSU
On/Off
Application
Figure 1: PXS8 system overview
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 19 of 41
2012-06-27
PXS8 Hardware Interface Overview
3 Application Interface
29

Application Interface
PXS8 is equipped with an SMT application interface that connects to the external application.
The host interface incorporates several sub-interfaces described in the following sections:
•
•
•
•
•
•
•
Operating modes - see Section 3.1
Power supply - see Section 3.2
Serial interface USB - see Section 3.3
Serial interface ASC0 - Section 3.4
UICC/SIM/USIM interface - see Section 3.5
Analog audio interface - see Section 3.6
Digital audio interface (PCM or I2S) - see Section 3.7
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 20 of 41
2012-06-27
PXS8 Hardware Interface Overview
3.1 Operating Modes
29
3.1

Operating Modes
The table below briefly summarizes the various operating modes referred to in the following
chapters.
Table 7: Overview of operating modes
Mode
Function
Normal
GSM /
operation GPRS / UMTS /
HSPA / CDMA
SLEEP
Power saving set automatically when no call is in progress and the USB
connection is suspended by host or not present and no active communication via ASC0.
GSM /
GPRS / UMTS /
HSPA / CDMA
IDLE
Power saving disabled (see [1]: AT^SCFG "MEopMode/
PwrSave",) or an USB connection not suspended, but
no call in progress.
GSM TALK/
GSM DATA
Connection between two subscribers is in progress. Power consumption depends on the GSM network coverage and several connection
settings (e.g. DTX off/on, FR/EFR/HR, hopping sequences and
antenna connection). The following applies when power is to be measured in TALK_GSM mode: DTX off, FR and no frequency hopping.
GPRS DATA
GPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates and
GPRS configuration (e.g. used multislot settings).
EGPRS DATA
EGPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates and
EGPRS configuration (e.g. used multislot settings).
UMTS TALK/
UMTS DATA
UMTS data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate.
HSPA DATA
HSPA data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate.
CDMA TALK/
CDMA DATA
CDMA data transfer in progress. Power consumption depends on network settings and data transfer rate.
Power
Down
Normal shutdown after sending the AT^SMSO command. Only a voltage regulator is active
for powering the RTC. Software is not active. Interfaces are not accessible. Operating voltage (connected to BATT+) remains applied.
Airplane
mode
Airplane mode shuts down the radio part of the module, causes the module to log off from
the GSM/GPRS/CDMA network and disables all AT commands whose execution requires
a radio connection.
Airplane mode can be controlled by AT command (see [1]).
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 21 of 41
2012-06-27

PXS8 Hardware Interface Overview
3.2 Power Supply
29
3.2
Power Supply
PXS8 needs to be connected to a power supply at the SMT application interface - 6 lines each
BATT+ and GND. There are three separate voltage domains for BATT+:
• BATT+_PA1 with 2 lines for the first power amplifier supply
• BATT+_PA2 with 2 lines for the second power amplifier supply
• BATT+ with 2 lines for the general power management.
The main power supply from an external application has to be a single voltage source and has
to be expanded to three sub paths (star structure). Capacitors should be placed as close as
possible to the BATT+ pads. Figure 2 shows two sample circuits (minimum requirement and
recommended alternative) for decoupling capacitors for BATT+.
Module
SMT interface
BATT+
BATT+_PA1
BATT+_PA2
BATT+
Minimum requirement
Decoupling capacitor
e.g. 100…220µF
Ultra-low ESR
GND
Module
SMT interface
BATT+
BATT+_PA1
BATT+_PA2
Recommended alternative
BATT+
3x
Decoupling capacitors
e.g. 47µF X5R MLCC
GND
Figure 2: Decoupling capacitor(s) for BATT+
The power supply of PXS8 must be able to provide the peak current during the uplink transmission.
All key functions for supplying power to the device are handled by the power management IC.
It provides the following features:
• Stabilizes the supply voltages for the baseband using switching regulators and low drop linear voltage regulators.
• Switches the module's power voltages for the power-up and -down procedures.
• Delivers, across the VEXT line, a regulated voltage for an external application. This voltage
is not available in Power-down mode and can be reduced via AT command to save power.
• SIM switch to provide SIM power supply.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 22 of 41
2012-06-27

PXS8 Hardware Interface Overview
3.3 USB Interface
29
3.3
USB Interface
PXS8 supports a USB 2.0 High Speed (480Mbit/s) device interface that is Full Speed (12Mbit/
s) compliant. The USB interface is primarily intended for use as command and data interface
and for downloading firmware.
The USB host is responsible for supplying the VUSB_IN line. This line is for voltage detection
only. The USB part (driver and transceiver) is supplied by means of BATT+. This is because
PXS8 is designed as a self-powered device compliant with the “Universal Serial Bus Specification Revision 2.0”1.
Module
SMT
VREG (3V075)
lin. reg.
BATT+
GND
USB part1)
VBUS
Detection only
VUSB_IN
USB_DP2)
USB_DN2)
DP
DN
Host wakeup
RING0
WAKEUP
1)
All serial and pull-up resistors for data lines are implemented.
If the USB interface is operated in High Speed mode (480MHz), it is recommended to take
special care routing the data lines USB_DP and USB_DN. Application layout should in this
case implement a differential impedance of 90Ohm for proper signal integrity.
2)
Figure 3: USB circuit
To properly connect the module's USB interface to the host a USB 2.0 compatible connector is
required. Furthermore, the USB modem driver distributed with PXS8 needs to be installed.
While the USB connection is active, the module will not change into SLEEP Mode. To enable
switching into SLEEP mode the USB host must bring its USB interface into Suspend state. Also, VUSB_IN should always be kept enabled for this functionality. See “Universal Serial Bus
Specification Revision 2.0“1 for a description of the Suspend state. On incoming calls PXS8 will
then generate a remote wake up request to resume the USB connection (active low).
As an alternative to the regular USB remote wakeup mechanism it is possible to employ the
RING0 or WAKEUP line to wake up the host application. The benefit is that the RING0 or
WAKEUP lines can wake up the host application in case of incoming calls or other events signalized by URCs while the USB interface is suspended or shut down.
1.
The specification is ready for download on http://www.usb.org/developers/docs/
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 23 of 41
2012-06-27
PXS8 Hardware Interface Overview
3.4 Serial Interface ASC0
29
3.4

Serial Interface ASC0
PXS8 offers an 8-wire unbalanced, asynchronous modem interface ASC0 conforming to ITUT V.24 protocol DCE signalling. The electrical characteristics do not comply with ITU-T V.28.
The significant levels are 0V (for low data bit or active state) and 1.8V (for high data bit or inactive state).
PXS8 is designed for use as a DCE. Based on the conventions for DCE-DTE connections it
communicates with the customer application (DTE) using the following signals:
• Port TXD @ application sends data to the module’s TXD0 signal line
• Port RXD @ application receives data from the module’s RXD0 signal line
Figure 4: Serial interface ASC0
Features:
• Includes the data lines TXD0 and RXD0, the status lines RTS0 and CTS0 and, in addition,
the modem control lines DTR0, DSR0, DCD0 and RING0.
• ASC0 is designed for controlling GSM/UMTS/CDMA voice calls, transferring data and for
controlling the module with AT commands.
• Full multiplexing capability allows the interface to be partitioned into virtual channels.
• The RING0 signal serves to indicate incoming calls and other types of URCs (Unsolicited
Result Code). It can also be used to send pulses to the host application, for example to
wake up the application from power saving state. See [1] for details on how to configure the
RING0 line by AT^SCFG.
• Configured for 8 data bits, no parity and 1 stop bit.
• ASC0 can be operated at fixed bit rates from 9600bps up to 921600bps.
• Supports RTS0/CTS0 hardware flow control.
• Wake up from SLEEP mode by RTS0 activation (high to low transition).
Note. If the ASC0 serial interface is the application’s only interface, it is suggested to connect
test points on the USB signal lines as a potential tracing possibility.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 24 of 41
2012-06-27

PXS8 Hardware Interface Overview
3.4 Serial Interface ASC0
29
Table 8: DCE-DTE wiring of ASC0
V.24 circuit DCE
DTE
Line function
Signal direction
Line function
Signal direction
103
TXD0
Input
TXD
Output
104
RXD0
Output
RXD
Input
105
RTS0
Input
RTS
Output
106
CTS0
Output
CTS
Input
108/2
DTR0
Input
DTR
Output
107
DSR0
Output
DSR
Input
109
DCD0
Output
DCD
Input
125
RING0
Output
RING
Input
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 25 of 41
2012-06-27
PXS8 Hardware Interface Overview
3.5 UICC/SIM/USIM Interface
29
3.5

UICC/SIM/USIM Interface
PXS8 has an integrated UICC/SIM/USIM interface compatible with the 3GPP 31.102 and ETSI
102 221. This is wired to the host interface in order to be connected to an external SIM card
holder. Five pads on the SMT application interface are reserved for the SIM interface.
The UICC/SIM/USIM interface supports 3V and 1.8V SIM cards.
The CCIN signal serves to detect whether a tray (with SIM card) is present in the card holder.
Using the CCIN signal is mandatory for compliance with the GSM 11.11 recommendation if the
mechanical design of the host application allows the user to remove the SIM card during operation. To take advantage of this feature, an appropriate SIM card detect switch is required on
the card holder. For example, this is true for the model supplied by Molex, which has been tested to operate with PXS8 and is part of the Cinterion reference equipment submitted for type
approval. See Chapter 9 for Molex ordering numbers.
Table 9: Signals of the SIM interface (SMT application interface)
Signal
Description
GND
Ground connection for SIM. Optionally a separate SIM ground line using e.g., pad J13 may
be used to improve EMC.
CCCLK
Chipcard clock
CCVCC
SIM supply voltage.
CCIO
Serial data line, input and output.
CCRST
Chipcard reset
CCIN
Input on the baseband processor for detecting a SIM card tray in the holder. If the SIM is
removed during operation the SIM interface is shut down immediately to prevent destruction of the SIM. The CCIN signal is active low.
The CCIN signal is mandatory for applications that allow the user to remove the SIM card
during operation.
The CCIN signal is solely intended for use with a SIM card. It must not be used for any other
purposes. Failure to comply with this requirement may invalidate the type approval of
PXS8.
Note: No guarantee can be given, nor any liability accepted, if loss of data is encountered after
removing the SIM card during operation. Also, no guarantee can be given for properly initializing any SIM card that the user inserts after having removed the SIM card during operation. In
this case, the application must restart PXS8.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 26 of 41
2012-06-27

PXS8 Hardware Interface Overview
3.5 UICC/SIM/USIM Interface
29
open: Card removed
closed: Card inserted
Module
SMT application interface
CCIN
CCRST
1n
SIM /
UICC
CCCLK
GND
CCIO
CCVCC 220n
Figure 5: UICC/SIM/USIM interface
The total cable length between the SMT application interface pads on PXS8 and the pads of
the external SIM card holder must not exceed 100mm in order to meet the specifications of
3GPP TS 51.010-1 and to satisfy the requirements of EMC compliance.
To avoid possible cross-talk from the CCCLK signal to the CCIO signal be careful that both
lines are not placed closely next to each other. A useful approach is using the GND line to
shield the CCIO line from the CCCLK line.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 27 of 41
2012-06-27
PXS8 Hardware Interface Overview
3.6 Analog Audio Interface
29
3.6

Analog Audio Interface
PXS8 has an analog audio interface with a balanced analog microphone input and a balanced
analog earpiece output. A supply voltage and an analog ground connection are provided at
dedicated lines.
PXS8 offers eight audio modes which can be selected with the AT^SNFS command. The electrical characteristics of the voiceband part vary with the audio mode. For example, sending and
receiving amplification, sidetone paths, noise suppression etc. depend on the selected mode
and can in parts be altered with AT commands (except for mode 1).
When shipped from factory, all audio parameters of PXS8 are set to audio mode 1. This is the
default configuration optimised for the Votronic HH-SI-30.3/V1.1/0 handset and used for type
approving the Cinterion Wireless Modules reference configuration. Audio mode 1 has fix parameters which cannot be modified. To adjust the settings of the Votronic handset simply
change to another audio mode.
3.7
Digital Audio Interface
PXS8 supports a digital audio interface that can be employed either as pulse code modulation
or as inter IC sound interface. Operation of these interface variants is mutually exclusive.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 28 of 41
2012-06-27
PXS8 Hardware Interface Overview
4 GPS Receiver
29

GPS Receiver
PXS8 integrates a GPS receiver that offers the full performance of GPS technology. The GPS
receiver is able to continuously track all satellites in view, thus providing accurate satellite position data.
The integrated GPS receiver supports the NMEA protocol via USB or ASC0 interface1. NMEA
is a combined electrical and data specification for communication between various (marine)
electronic devices including GPS receivers. It has been defined and controlled by the USbased National Marine Electronics Association. For more information on the NMEA Standard
please refer to http://www.nmea.org.
Depending on the receiver’s knowledge of last position, current time and ephemeris data, the
receiver’s startup time (i.e., TTFF = Time-To-First-Fix) may vary: If the receiver has no knowledge of its last position or time, a startup takes considerably longer than if the receiver has still
knowledge of its last position, time and almanac or has still access to valid ephimeris data and
the precise time.
By default, the GPS receiver is switched off. It has to be switched on and configured using AT
commands. For more information on how to control the GPS interface via the AT command
AT^SGPSC see [1].
1.
Using the serial ASC0 interface NMEA data is transmitted at a fixed speed of 115200bps.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 29 of 41
2012-06-27

PXS8 Hardware Interface Overview
5 Antenna Interfaces
33
Antenna Interfaces
5.1
GSM/UMTS/CDMA Antenna Interface
The PXS8 GSM/UMTS/CDMA antenna interface comprises a main GSM/UMTS/CDMA antenna as well as an optional UMTS/CDMA Rx diversity antenna to improve signal reliability and
quality1. The interface has an impedance of 50. PXS8 is capable of sustaining a total mismatch at the antenna interface without any damage, even when transmitting at maximum RF
power.
The external antenna must be matched properly to achieve best performance regarding radiated power, modulation accuracy and harmonic suppression. Matching networks are not included on the PXS8 PCB and should be placed in the host application, if the antenna does not
have an impedance of 50.
Regarding the return loss PXS8 provides the following values in the active band:
Table 10: Return loss in the active band
State of module
Return loss of module
Recommended return loss of application
Receive
> 8dB
> 12dB
Transmit
not applicable
> 12dB
Idle
< 5dB
not applicable
1.
By delivery default the optional UMTS/CDMA Rx diversity antenna is configured as available for the module. To avoid negative side effects and performance degradation it is recommended to disable the diversity antenna path if
- the host application does not support a diversity antenna
- the host application includes a diversity antenna - but a 3G network simulator is used for development
and performance tests.
Please refer to [1] for details on how to configure antenna settings.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 30 of 41
2012-06-27
PXS8 Hardware Interface Overview
5.1 GSM/UMTS/CDMA Antenna Interface
33
5.1.1

Antenna Installation
The antenna is connected by soldering the antenna pads and their neighboring ground pads
directly to the application’s PCB.
The distance between the antenna pads and their neighboring GND pads has been optimized
for best possible impedance. To prevent mismatch, special attention should be paid to these
pads on the application’ PCB.
The wiring of the antenna connection, starting from the antenna pad to the application’s antenna should result in a 50 line impedance. Line width and distance to the GND plane need to
be optimized with regard to the PCB’s layer stack.
To prevent receiver desensitization due to interferences generated by fast transients like high
speed clocks on the external application PCB, it is recommended to realize the antenna connection line using embedded Stripline rather than Micro-Stripline technology.
For type approval purposes, the use of a 50 coaxial antenna connector (U.FL-R-SMT) might
be necessary. In this case the U.FL-R-SMT connector should be placed as close as possible
to PXS8‘s antenna pad.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 31 of 41
2012-06-27

PXS8 Hardware Interface Overview
5.2 GPS Antenna Interface
33
5.2
GPS Antenna Interface
In addition to the RF antenna interface PXS8 also has a GPS antenna interface. The GPS antenna installation and connector are the same as for the RF antenna interface (see Section
5.1.1).
It is possible to connect active or passive GPS antennas. In either case they must have 50 Ohm
impedance. The simultaneous operation of GSM/CDMA and GPS has been implemented. For
electrical characteristics see Section 6.9.
PXS8 provides the supply voltage VGPS for the GPS active antenna (3.05V). It has to be enabled by software when the GPS-receiver shall becomes active, otherwise VGPS should be off
(power saving). VGPS is not short circuit protected. This will have to be provided for by an external application. The DC voltage should be fed back via ANT_GPS_DC for coupling into the
GPS antenna path. Figure 6 shows the flexibility in realizing the power supply for an active GPS
antenna by giving two sample circuits realizing the supply voltage for an active GPS antenna one with short circuit protection and one with an external LDO employed.
Module
SMT interface
typ 3.05V max. 300mA
Not short circuit protected!
VGPS
Short circuit
protection
(Imax=50mA)
47pF
ANT_GPS_DC
Active
GPS
antenna
(Optional)
10k
1uF
10nH
ESD
protection
ANT_GPS
2p2
Supply with short circuit protection
External
voltage
Module
SMT interface
Enable
VGPS
47pF
LDO
ANT_GPS_DC
(Optional)
10k
10nH
1uF
ESD
protection
Active
GPS
antenna
ANT_GPS
2p2
Supply with external LDO employed
Figure 6: Supply voltage for active GPS antenna
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 32 of 41
2012-06-27

PXS8 Hardware Interface Overview
5.2 GPS Antenna Interface
33
Figure 7 shows sample circuits realizing ESD protection for a passive GPS antenna.
Module
SMT interface
VGPS
47pF
Not used
ANT_GPS_DC
(Optional)
0R
ESD
protection
Passive
GPS
antenna
10nH
ANT_GPS
2p2
Figure 7: ESD protection for passive GPS antenna
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 33 of 41
2012-06-27
PXS8 Hardware Interface Overview
6 Mechanics, Mounting and Packaging
35
Mechanics, Mounting and Packaging
6.1
Mechanical Dimensions of PXS8

Figure 8 shows a 3D view1 of PXS8 and provides an overview of the board's mechanical dimensions. For further details see Figure 9.
Length:
33mm
Width:
29mm
Height:
2mm
Top view
Bottom view
Figure 8: PXS8 – top and bottomview
1.
The coloring of the 3D view does not reflect the module’s real color.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 34 of 41
2012-06-27

PXS8 Hardware Interface Overview
6.1 Mechanical Dimensions of PXS8
35
Position marker
Internal use;
Not to be soldered
Figure 9: Dimensions of PXS8 (all dimensions in mm)
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 35 of 41
2012-06-27
PXS8 Hardware Interface Overview
7 Sample Application
37

Sample Application
Figure 10 shows a typical example of how to integrate an PXS8 module with an application.
The audio interface demonstrates the balanced connection of microphone and earpiece. This
solution is particularly well suited for internal transducers.
The PWR_IND line is an open collector that needs an external pull-up resistor which connects
to the voltage supply VCC µC of the microcontroller. Low state of the open collector pulls the
PWR_IND signal low and indicates that the PXS8 module is active, high level notifies the Power-down mode.
If the module is in Power-down mode avoid current flowing from any other source into the module circuit, for example reverse current from high state external control lines. Therefore, the
controlling application must be designed to prevent reverse flow. If an external level controller
is required, this can be done by using for example a 5V I/O tolerant buffer/driver like a
"74AVC4T245" with OE (Output Enable) controlled by PWR_IND.
While developing SMT applications it is strongly recommended to provide test points
for certain signals resp. lines to and from the module - for debug and/or test purposes.
The SMT application should allow for an easy access to these signals. For details on
how to implement test points see [4].
The EMC measures are best practice recommendations. In fact, an adequate EMC strategy for
an individual application is very much determined by the overall layout and, especially, the position of components.
Disclaimer:
No warranty, either stated or implied, is provided on the sample schematic diagram shown in
Figure 10 and the information detailed in this section. As functionality and compliance with national regulations depend to a great amount on the used electronic components and the individual application layout manufacturers are required to ensure adequate design and operating
safeguards for their products using PXS8 modules.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 36 of 41
2012-06-27

PXS8 Hardware Interface Overview
7 Sample Application
37
PXS8
Sample Application
Current
limiter
<60mA
ANT_MAIN
VGPS
ANT_DRX
ANT_GPS
BC847
47k
47k
EMERG_RST
BC847
VCC µC
100k
PWR_IND
VDD
(1.8V)
100µF
...220µF
ultra low ESR
VEXT (1.8V)
470R
1µF
1k
FB*
VCC µC
V CCA
OE
VCCB
1µF
Level
Controller
FB*
1k
FB*
51R
51R
51R
CCIN
CCVCC
CCRST
EPP
CCCLK
AGND
220nF 1nF
Figure 10: PXS8 sample application
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 37 of 41
2012-06-27

PXS8 Hardware Interface Overview
8 Reference Approval
39
Reference Approval
8.1
Reference Equipment for Type Approval
The Cinterion Wireless Modules reference setup submitted to type approve PXS8 is shown in
Figure 11. The module (i.e., the evaluation module) is connected to the DSB75 by means of a
flex cable and a special DSB75 adapter. The GSM/UMTS/CDMA/GPS test equipment is connected via edge mount SMA connectors soldered to the module’s antenna pads.
For ESD tests and evaluation purposes, it is also possible connect the module to the GSM/
UMTS/CDMA/GPSS test equipment through an SMA-to-Hirose-U.FL antenna cable and the
SMA antenna connectors of the DSB75 adapter.
A further option is to mount the evaluation module directly onto the DSB75 adapter’s 80-pin
board-to-board connector and to connect the test equipment as shown below.
A udio
test equipm ent
V otronic
handset
an
alo
ga
ud
io
D etail:
If u
sin
Edge m ount SM A connectors
m anually soldered to antenna pads
S tandard
80 polig Flex
PX S 8
evaluation
m odule
P X S8
U ranus
evaluation
m odule
USB
SM
GPS
test equipm ent
At
H ir
os
COM1
(A S C 0)
D SB 75 adapter
eU
.F L
ca
b le
GPS
A N T3
A N T2
G S M /U M TS/
CDMA
test equipm ent
U M TS /C D M A D rx
A N T1
P ow er
A ud io
GND
G S M /U M TS /C D M A M ain
A udio
D S B 75
USB
cable
PC
Pow er
supply
R S 232
cable
Figure 11: Reference equipment for type approval
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 38 of 41
2012-06-27
PXS8 Hardware Interface Overview
8.2 Compliance with FCC and IC Rules and Regulations
39
8.2

Compliance with FCC and IC Rules and Regulations
The Equipment Authorization Certification for the Cinterion Wireless Modules reference application described in Section 8.1 will be registered under the following identifiers:
FCC Identifier QIPPXS8
Industry Canada Certification Number: 7830A-PXS8
Granted to Cinterion Wireless Modules GmbH
Manufacturers of mobile or fixed devices incorporating PXS8 modules are authorized to use
the FCC Grants and Industry Canada Certificates of the PXS8 modules for their own final products according to the conditions referenced in these documents. In this case, the FCC label of
the module shall be visible from the outside, or the host device shall bear a second label stating
"Contains FCC ID QIPPXS8" and accordingly “Contains IC 7830A-PXS8“. The integration is
limited to fixed or mobile categorised host devices, where a separation distance between the
antenna and any person of min. 20cm can be assured during normal operating conditions. For
mobile and fixed operation configurations the antenna gain, including cable loss, must not exceed the limits 3.92 dBi (850 MHz) and 2.51 dBi (1900 MHz).
IMPORTANT:
Manufacturers of portable applications incorporating PXS8 modules are required to have their
final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable mobile. This is mandatory to meet the SAR requirements for portable
mobiles (see Section 1.3.1 for detail).
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules and with Industry Canada licence-exempt RSS
standard(s). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This Class B digital apparatus complies with Canadian ICES-003.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 39 of 41
2012-06-27

PXS8 Hardware Interface Overview
9 Appendix
41
Appendix
9.1
List of Parts and Accessories
Table 11: List of parts and accessories
Description
Supplier
Ordering information
PXS8
Cinterion
Standard module
Cinterion Wireless Modules IMEI:
Ordering number: L30960-N2600-A100
PXS8 Evaluation Module
Cinterion
Ordering number: L30960-N2601-A100
DSB75 Support Box
Cinterion
Ordering number: L36880-N8811-A100
DSB75 adapter for mounting Cinterion
the PXS8 evaluation module
Ordering number: L30960-N2301-A100
Votronic Handset
VOTRONIC
Votronic HH-SI-30.3/V1.1/0
VOTRONIC
Entwicklungs- und Produktionsgesellschaft für elektronische Geräte mbH
Saarbrücker Str. 8
66386 St. Ingbert
Germany
Phone: +49-(0)6 89 4 / 92 55-0
Fax: +49-(0)6 89 4 / 92 55-88
Email: contact@votronic.com
SIM card holder incl. push
button ejector and slide-in
tray
Molex
Ordering numbers: 91228
91236
Sales contacts are listed in Table 12.
U.FL antenna connector
Hirose or Molex Sales contacts are listed in Table 12 and Table 13.
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 40 of 41
2012-06-27
PXS8 Hardware Interface Overview
9.1 List of Parts and Accessories
41

Table 12: Molex sales contacts (subject to change)
Molex
For further information please click:
http://www.molex.com
Molex Deutschland GmbH
Otto-Hahn-Str. 1b
69190 Walldorf
Germany
Phone: +49-6227-3091-0
Fax: +49-6227-3091-8100
Email: mxgermany@molex.com
American Headquarters
Lisle, Illinois 60532
U.S.A.
Phone: +1-800-78MOLEX
Fax: +1-630-969-1352
Molex China Distributors
Beijing,
Room 1311, Tower B, COFCO Plaza
No. 8, Jian Guo Men Nei Street, 100005
Beijing
P.R. China
Phone: +86-10-6526-9628
Fax: +86-10-6526-9730
Molex Singapore Pte. Ltd.
110, International Road
Jurong Town,
Singapore 629174
Molex Japan Co. Ltd.
1-5-4 Fukami-Higashi,
Yamato-City,
Kanagawa, 242-8585
Japan
Phone: +65-6-268-6868
Fax: +65-6-265-6044
Phone: +81-46-265-2325
Fax: +81-46-265-2365
Table 13: Hirose sales contacts (subject to change)
Hirose Ltd.
For further information please click:
http://www.hirose.com
Hirose Electric (U.S.A.) Inc
2688 Westhills Court
Simi Valley, CA 93065
U.S.A.
Phone: +1-805-522-7958
Fax: +1-805-522-3217
Hirose Electric Europe B.V.
German Branch:
Herzog-Carl-Strasse 4
73760 Ostfildern
Germany
Phone: +49-711-456002-1
Fax: +49-711-456002-299
Email: info@hirose.de
Hirose Electric Europe B.V.
UK Branch:
First Floor, St. Andrews House,
Caldecotte Lake Business Park,
Milton Keynes MK7 8LE
Great Britain
Hirose Electric Co., Ltd.
5-23, Osaki 5 Chome,
Shinagawa-Ku
Tokyo 141
Japan
Hirose Electric Europe B.V.
Hogehillweg 8
1101 CC Amsterdam Z-O
Netherlands
Phone: +44-1908-369060
Fax: +44-1908-369078
Phone: +81-03-3491-9741
Fax: +81-03-3493-2933
Phone: +31-20-6557-460
Fax: +31-20-6557-469
PXS8_HIO_v00.110a
Confidential / Preliminary
Page 41 of 41
2012-06-27

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : chinrich
Create Date                     : 2012:06:27 15:05:25Z
Modify Date                     : 2012:06:27 15:11:14+02:00
XMP Toolkit                     : Adobe XMP Core 4.2.2-c063 53.352624, 2008/07/30-18:12:18
Format                          : application/pdf
Creator                         : chinrich
Title                           : hid.book
Creator Tool                    : FrameMaker 9.0
Metadata Date                   : 2012:06:27 15:11:14+02:00
Producer                        : Acrobat Distiller 9.5.1 (Windows)
Document ID                     : uuid:fd63e92c-3081-4ce8-964b-d33064d0afc6
Instance ID                     : uuid:2010528d-95b2-4b46-9f42-aebb090241b7
Page Mode                       : UseOutlines
Page Count                      : 41
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QIPPXS8

Navigation menu