TRANE Package Units(both Units Combined) Manual L0903060
User Manual: TRANE TRANE Package Units(both units combined) Manual TRANE Package Units(both units combined) Owner's Manual, TRANE Package Units(both units combined) installation guides
Open the PDF directly: View PDF .
Page Count: 28
Download | |
Open PDF In Browser | View PDF |
18-BG02D1-5 STALLATI OP RATIO T CE ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Model: DCY024F1 DCY030FI DCY036F1,3,4 DOY048F1,3,4 DCY060F1,3,4 BAYLIFT002AA LIFTING LUG KIT Single Package Dual Fuel Heat Pump Convertible 2 - 5 Ton 12 SEER IMPORTANT -- This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work. All phases of this installation must comply with the NATIONAL, STATE & LOCAL CODES. In the absence of local codes, the installation must conform with National Electric Code -ANSI/NFPA 70 or "LATEST REVISION': OTlCE Warnings _,WARNING: and Cautions appear at appropriate locations Read these carefully. Indicates a potentially hazardous throughout this manual. situation which, if not avoided, could result in death or serious injury. ,_CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices and where property-damage-only accidents could occur. © 2003 American Standard Inc. All rights reserved Dwgo No. X664366 P01 10/03 GENERAL IMPORTANT: Read this entire beginning manual installation kWARNING: INFORMATION before procedures. 3. Check to be sure the refrigerant charge has been retained during shipment. Access to 1/4" flare pressure taps may be gained by removing the furnace compartment access panel. BOD,LY ,NJURY CAN RESU'T FROM HIGH VOLTAGE ELECTRICAL COMPONENTS, FAST MOVING FANS, AND COMBUSTIBLE GAS. FOR PROTECTION FROM THESE INHERENT HAZARDS DURING INSTALLATION AND SERVICING, THE ELECTRICAL SUPPLY MUST BE DISCONNECTED AND THE MAIN GAS VALVE MUST BE TURNED OFF. IF OPERATING CHECKS MUST BE PERFORMED WITH THE UNIT OPERATING, IT IS THE TECHNICIANS RESPONSIBILTY TO RECOGNIZE THESE HAZARDS AND PROCEED SAFELY. Read this manual carefully before attempting to install, operate, or perform maintenance on this unit. Installation and maintenance should be performed by qualified service technicians only. As shipped from the factory, this unit is for use with natural gas only, and is listed by Underwriters Laboratory. Model DCY-F heating/cooling units are designed for outdoor mounting with a vertical condenser discharge. They can be located either at ground level or on a roof, in accordance with local codes or National Fuel Gas Code (ANSI-Z223.1A) Latest Revision. Since these units are designed exclusively for outdoor operation, additional flue venting systems are not required. Each unit contains an operating charge of Refrigerant-22 as shipped. IMPORTANT: DO NOT CONNECT GAS PIPING TO THE UNIT UNTIL A LINE PRESSURE TEST HAS BEEN COMPLETED. DAMAGE TO THE GAS VALVE MAY RESULT IN AN UNSAFE CONDITION. THIS UNIT SHOULD NEVER BE EXPOSED TO GAS LINE PRESSURE IN EXCESS OF 13.8 INCHES WATER COLUMN. (1/2 PSIG) IMPORTANT: RECONNECT ALL GROUNDING DEVICES. ALL PARTS OF THIS PRODUCT CAPABLE OF CONDUCTING ELECTRICAL CURRENT ARE GROUNDED. IF GROUNDING WIRES, SCREWS, STRAPS, CLIPS NUTS OR WASHERS USED TO COMPLETE A PATH TO GROUND ARE REMOVED FOR SERVICE, THEY MUST BE RETURNED TO THEIR ORIGINAL POSITION AND PROPERLY FASTENED. IMPORTANT: ALL POWER LEGS MAY NOT BE BROKEN BY CONTACTORS. SEE WIRING DIAGRAM ON UNIT CONTROL BOX COVER. THIS UNIT, AS SHIPPED FROM THE SIGNED FOR NATURAL GAS ONLY. FACTORY, IS DE- BEFORE STARTING THE COMPRESSOR, THE CRANKCASE HEATER SHOULD BE ENERGIZED FOR EIGHT HOURS INSPECTION 1. Checkfor damage after the unit is unloaded. Report promptly, to the carrier, any damage found to the unit. Do not drop the unit. iMPORTANT: when hoisting top). The use of "spreader bars" is required the unit (to prevent damage to sides and 2. Check the unit's nameplate to determine if the unit is correct for the intended application. The power supply must be adequate for both the unit and all accessories. The following warning complies with State of California kWARNING: law, Proposition This product contains MEASURES warning complies with State of California WARNING: law, Proposition 65. Hazardous Gasses! Exposure to fuel substances or by-products of incomplete fuel combustion is believed by the state of California to cause cancer, birth defects, or other reproductive harm. 65. fiberglass wool insulation! Fiberglass dust and ceramic fibers are believed by the State of California to cause cancer through inhalation. Glasswool fibers may also cause respiratory, skin, or eye irritation. PRECAUTIONARY The following • Wash clothes separately from other clothing: rinse washer thoroughly. Operations such as sawing, blowing, tear-out, and spraying may generate fiber concentrations requiring additional respiratory protection. Use the appropriate NIOSH approved respirator in these situations. FIRST AID MEASURES • Avoid breathing fiberglass dust. Eye Contact • Use a NIOSH approved dust/mist respirator. • Avoid contact with the skin or eyes. Wear longsleeved, loose-fitting clothing, gloves, and eye protection. Page 2 Skin Contact Flush eyes with water to remove dust. If symptoms persist, seek medical attention. Wash affected areas gently with soap and warm water after handling. Dwg. No. X664366 P01 TYPICAL ROOFTOP iNSTALLATiON WiTH FULL PERIMETER CURBS ./ • CANT FIELD SUPPLIED SUPPORTS AT EACH END OF CURB SUPPLIED STRIP FIELD SUPPLIED RIGIDINSULATiON ROOF SUPPLY AIR DUCT @ TYPICAL ROOFTOP SEE NOTE _ _ iNSTALLATiON RETURN MOUNTING CURB AIR DUCT WiTH BAYCURB030/38A 1 SEE NOTE 2 • FIELD SUPPLIED CANT STRIP \ FIELD SUPPLIED RIGIDINSULATION 1. The DCY024-042F the curb ONLY. f SUPPLY AIR DUCT NOTES: models extend out past this end of FIELD SUPPLIED SUPPORTS AT EACH END OFCURB ROOFMOUNTING CURB RETURN AIR DUCT 2. Only theDCY048F,060F models extend past both the end and the side of the curb as illustrated• Dwg. No. X664366 P01 Page 3 DiMENSiONAL ® DCY024=060F Outline (All dimensions SUPPLY RE[URN DATA & ==Rear are in inches) ECONOM}ZER/Fll ACCESS C TER EVAPOF
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 28 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Fri Mar 13 04:14:59 2009 Author : Title : Subject :EXIF Metadata provided by EXIF.tools