TRANE Furnace/Heater, Gas Manual L0903218
User Manual: TRANE TRANE Furnace/Heater, Gas Manual TRANE Furnace/Heater, Gas Owner's Manual, TRANE Furnace/Heater, Gas installation guides
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
IIIIII IIIIIIIIIIIIII IIIIII 1 8- CH2 2 D2- 6 BAYVENT200B For use with *UX, *DX, *UY, AND *DY models DIRECT VENT FURNACE SiDE WALL VENT KiT *__First letter ma be "A", "C" or "T" of this installation ALL phases must comply with NATIONAL, IMPORTANT -- This Document is customer P]ease return to service information STATE AND LOCAL CODES property and is to remain with this unit. pack upon comp]etion of' work. THIS VENT KIT IS ONLY TO BE USED FOR VENTING CATEGORY IV FURNACES. DO NOT USE TO VENT CATEGORY I, II, Ill VENT FURNACES. FAILURE TO FOLLOWTHIS WARNING COULD RESULT IN FIRE, PERSONAL INJURY OR DEATH. TYPICAL VERTICAL DO NOT NACE INSTALLATION APPLY TO A NON-CONDENSING NOTE: If these instructions differ from those the furnace, follow these instructions. TYPICAL NOTE: the ing, Codes HORIZONTAL and installation and flue utility fired connections absence with the of local National tion", or CAN/CGA code may Services, local of gas be codes, Fuel obtained 8501 B149 adhered Installation from E. Pleasant the Rd., NOTE: Read installation. the Installer's length plumbto. In the must conform Z223.1 'latest ediCodes. The latest InternationalApproval Valley Searsdale vent wiring, the installation Gas CodeANSI 44131, or 55 M3B 2R3. The equivalent feet. be Rd, Toronto, Guide Cleveland, Ontario, before Ohio GENERAL This vent kit may be used on 2, 2-1/2, or 3 inch vent systems. The vent kit must terminate outside the structure and may be installed with the pipes side by side or with one pipe above the other as shown in Figure 1. It is not required for the vent kit to be installed in a specific orientation. Canada, starting of the BAYVENT2OOB the is 0 INTRODUCTION This Installer's guide covers installation of the side wall venting kit on all gas fired direct vent condensing furnaces. © 2004 American Standard inc. All Rights Reserved with governing equipment, must packaged INSTALLING AND SERVICING HEATING EQUIPMENT CAN BE HAZARDOUS DUE TO GAS AND ELECTRICAL COMPONENTS. ONLYTRAINED PERSONNEL SHOULD INSTALL OR SERVICE HEATING EQUIPMENT TO PREVENT PRODUCT DAMAGE OR PERSONAL INJURY. INSTALLATION requirements GAS FUR- Field supplied pipe and fittings are required to complete the installation. The combustion air pipe, vent pipe and fittings must conform to American National Standards Institute (ANSI) and American Society for Testing and Materials (ASTM) standards D-1785 (schedule-40 PVC), D-2665 (PVCDWV), D-2661 (ABS-DWV), or F628 (schedule-40 ABS). Pipe cement and primer must conform to ASTM standard D-2564 (PVC). In Canada, construct all combustion air and vent pipes for this unit of CSA or ULC certified schedule-40 PVC/ABSDWV pipe and pipe cement. Pub. No. 18-CD22D2-6 INSTALLATION 1. Determine NOTE: - Side Wahl Vent the best location Kit TYPICAL for the vent kit. In addition to all applicable local codes, consider following when determining the vent kit location: SiDE WALL APPLiCATiON the ANCHORS • The vent kit should be positioned where the vent vapors and flue gas condensate will not damage building materials, plants, shrubs, or air conditioning equipment. • The vent kit should be positioned so it will not be affected by wind currents that may allow recireulation of combustion products, airborne leaves, snow flakes, etc. • The vent kit should aged or be subjected etc.). 12" MINIMUM TO OVERHANG 1" SCREWS (4 req.) be positioned where it will not get damto foreign objects (such as stones, balls, / / / • The vent kit should not be positioned will be objectionable. where the CAP L vent vapors MAINTAIN 12" (18" FOR CANADA) MINIMUM CLEARANCE ABOVE HIGHEST ANTICIPATED SNOW LEVEL OR GRADE WHICHEVER IS GREATEF 2" SCREWS (4 req.) 2. Use the vent plate as a template to locate the vent and air intake holes and four mounting holes. Cut two 3-7/8 inch diameter holes for the vent and air intake openings. Drill four 3/16" diameter holes for inserting the plastic anchors into the wall. Attach the vent plate to the wall with four screws (#8 pan, 2" long, SMS Type A18-8 stainless steel). 3. Assemble the vent cap to the vent plate (see Figure 2). Insert the four (#8 pan, 1" long, SMS TypeA 18-8 stainless steel) screws into the vent cap screw hole openings and securely attach the vent cap to the vent plate. 4. Install the vent and air intake piping into the vent plate openings. Seal all gaps between the pipes and wall. Use RTV silicon sealant to seal the vent pipe to the vent cap to permit field disassembly for cleaning. To reduce to 2" or 2-1/2" piping, reducing couplings are required but not supplied (see Figure 3). ® TOP ViEW - Typical REDUCING COUPLING, FIELD SUPPLIED IF NEEDED installation Note* ..... I \, 2", 2-1/2" or 3" 5. Seal all wall cavities. 3" PIPING NOTE: Two or more installations require a minimum separation distance of approximately one inch between vent kits. To prevent the possiblility of condenate freeze-up, do not install vent kits one above the other. WALL CAVITIES Note* CHECKOUT Install enough secure reducing 3" PVC pipe stub in order to adequately couplings. Operate the furnace to make sure all pipe joints are thstened and sealed to prevent the escape of combustion products into the building. DO NOT OPERATETHE FURNACE WffHOUTTHE SIDEWALL CAP iN PLACE AS RECIRCULATION OF COMBUSTION PRODUCTS MAY OCCUR. WATER MAY ALSO COLLECT iNSIDE THE COMBUSTION AIR PIPE AND FLOWTO THE BURNER ENCLOSURE. FAILURE TO FOLLOW THB WARNING COULD RESULT iN PRODUCT DAMAGE OR IMPROPPER OPERATION, PERSONAL INJURY OR DEATH. American Standard Inc. 6200Troup Highway Tyler, TX 75707 For more information contact your loca! dealer (distributed Since the manufacturer has a policy of continuous product and product data linprovement, to change design and specifications without notice. it reserves the right Pub. No. 18-CD22D2-6
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 2 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Mon Mar 23 04:15:10 2009 Author : Title : Subject :EXIF Metadata provided by EXIF.tools