TRANE Furnace/Heater, Gas Manual L0903218

User Manual: TRANE TRANE Furnace/Heater, Gas Manual TRANE Furnace/Heater, Gas Owner's Manual, TRANE Furnace/Heater, Gas installation guides

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadTRANE  Furnace/Heater, Gas Manual L0903218
Open PDF In BrowserView PDF
IIIIII IIIIIIIIIIIIII IIIIII
1 8- CH2 2 D2- 6

BAYVENT200B
For use with *UX, *DX, *UY, AND *DY models

DIRECT VENT FURNACE
SiDE WALL VENT KiT
*__First letter ma be "A", "C" or "T"
of this installation

ALL phases

must

comply

with

NATIONAL,

IMPORTANT
-- This Document is customer
P]ease return to service information

STATE AND LOCAL

CODES

property
and is to remain with this unit.
pack upon comp]etion of' work.

THIS VENT KIT IS ONLY TO BE USED FOR VENTING
CATEGORY IV FURNACES. DO NOT USE TO VENT CATEGORY I, II, Ill VENT FURNACES. FAILURE TO FOLLOWTHIS
WARNING COULD RESULT IN FIRE, PERSONAL INJURY OR
DEATH.

TYPICAL

VERTICAL

DO NOT
NACE

INSTALLATION

APPLY

TO A NON-CONDENSING

NOTE: If these instructions
differ from those
the furnace, follow these instructions.

TYPICAL
NOTE:
the
ing,

Codes

HORIZONTAL
and

installation
and

flue

utility
fired

connections

absence
with the

of local
National

tion",

or

CAN/CGA

code

may

Services,

local
of gas

be

codes,
Fuel

obtained

8501

B149

adhered

Installation

from

E. Pleasant

the

Rd.,

NOTE: Read
installation.

the Installer's
length

plumbto.

In

the

must
conform
Z223.1 'latest
ediCodes.

The

latest

InternationalApproval

Valley

Searsdale

vent

wiring,

the installation
Gas CodeANSI

44131,
or 55
M3B 2R3.

The equivalent
feet.

be

Rd,

Toronto,

Guide

Cleveland,
Ontario,

before

Ohio

GENERAL
This vent kit may be used on 2, 2-1/2, or 3 inch vent systems.
The vent kit must terminate
outside the structure
and may
be installed with the pipes side by side or with one pipe above
the other as shown in Figure 1. It is not required for the vent
kit to be installed in a specific orientation.

Canada,

starting

of the BAYVENT2OOB

the
is 0

INTRODUCTION
This Installer's guide covers installation
of the side wall venting kit on all gas fired direct vent condensing
furnaces.
© 2004 American Standard inc. All Rights Reserved

with

governing

equipment,
must

packaged

INSTALLING AND SERVICING HEATING EQUIPMENT CAN
BE HAZARDOUS DUE TO GAS AND ELECTRICAL COMPONENTS. ONLYTRAINED PERSONNEL SHOULD INSTALL OR
SERVICE HEATING EQUIPMENT TO PREVENT PRODUCT
DAMAGE OR PERSONAL INJURY.

INSTALLATION

requirements

GAS FUR-

Field supplied pipe and fittings are required to complete the
installation.
The combustion
air pipe, vent pipe and fittings
must conform to American
National
Standards
Institute
(ANSI) and American
Society for Testing
and Materials
(ASTM) standards
D-1785 (schedule-40
PVC), D-2665 (PVCDWV), D-2661 (ABS-DWV), or F628 (schedule-40
ABS). Pipe
cement and primer must conform to ASTM standard
D-2564
(PVC). In Canada, construct all combustion air and vent pipes
for this unit of CSA or ULC certified schedule-40
PVC/ABSDWV pipe and pipe cement.
Pub. No. 18-CD22D2-6

INSTALLATION
1. Determine
NOTE:

- Side Wahl Vent

the best location

Kit

TYPICAL

for the vent kit.

In addition to all applicable
local codes, consider
following when determining
the vent kit location:

SiDE WALL

APPLiCATiON

the

ANCHORS

• The vent
kit should
be positioned
where
the vent
vapors and flue gas condensate
will not damage building
materials,
plants, shrubs, or air conditioning
equipment.
• The vent kit should be positioned so it will not be affected by
wind currents that may allow recireulation
of combustion products, airborne leaves, snow flakes, etc.
• The vent kit should
aged or be subjected
etc.).

12" MINIMUM
TO OVERHANG

1" SCREWS
(4 req.)

be positioned where it will not get damto foreign objects (such as stones, balls,
/
/
/

• The vent kit should not be positioned
will be objectionable.

where the

CAP

L

vent vapors

MAINTAIN 12" (18" FOR CANADA) MINIMUM
CLEARANCE ABOVE HIGHEST ANTICIPATED
SNOW LEVEL OR GRADE WHICHEVER IS GREATEF

2" SCREWS
(4 req.)

2. Use the vent plate as a template
to locate the vent and air
intake holes and four mounting
holes. Cut two 3-7/8 inch diameter holes for the vent and air intake openings. Drill four 3/16"
diameter
holes for inserting
the plastic anchors into the wall.
Attach the vent plate to the wall with four screws (#8 pan, 2"
long, SMS Type A18-8 stainless steel).
3. Assemble the vent cap to the vent plate (see Figure 2). Insert
the four (#8 pan, 1" long, SMS TypeA 18-8 stainless steel) screws
into the vent cap screw hole openings and securely attach the
vent cap to the vent plate.
4. Install the vent and air intake piping into the vent plate openings. Seal all gaps between the pipes and wall. Use RTV silicon
sealant to seal the vent pipe to the vent cap to permit field
disassembly
for cleaning. To reduce to 2" or 2-1/2" piping, reducing couplings are required but not supplied (see Figure 3).

®

TOP ViEW - Typical
REDUCING
COUPLING,
FIELD SUPPLIED
IF NEEDED

installation

Note*

.....
I

\,
2", 2-1/2"
or 3"

5. Seal all wall cavities.
3" PIPING

NOTE: Two or more installations
require a minimum
separation distance
of approximately
one inch between
vent
kits.
To prevent
the possiblility
of condenate
freeze-up,
do not
install
vent kits one above the other.

WALL

CAVITIES

Note*

CHECKOUT

Install enough
secure reducing

3" PVC pipe stub in order to adequately
couplings.

Operate the furnace to make sure all pipe joints are thstened
and sealed to prevent the escape of combustion
products into
the building.

DO NOT OPERATETHE FURNACE WffHOUTTHE SIDEWALL
CAP iN PLACE AS RECIRCULATION OF COMBUSTION
PRODUCTS MAY OCCUR. WATER MAY ALSO COLLECT
iNSIDE THE COMBUSTION AIR PIPE AND FLOWTO THE
BURNER ENCLOSURE. FAILURE TO FOLLOW THB WARNING
COULD RESULT iN PRODUCT DAMAGE OR IMPROPPER
OPERATION, PERSONAL INJURY OR DEATH.

American Standard Inc.
6200Troup Highway
Tyler, TX 75707
For more information contact
your loca! dealer (distributed

Since the manufacturer has a policy of continuous product and product data linprovement,
to change design and specifications without notice.

it reserves the right

Pub. No. 18-CD22D2-6



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 2
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 4, 0, 0, 13
Create Date                     : Mon Mar 23 04:15:10 2009
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu