TRANE Air Conditioner/heat Pump(outside Unit) Manual L0905062
User Manual: TRANE TRANE Air conditioner/heat pump(outside unit) Manual TRANE Air conditioner/heat pump(outside unit) Owner's Manual, TRANE Air conditioner/heat pump(outside unit) installation guides
Open the PDF directly: View PDF .
Page Count: 8
18=AC51D6=1
iiI!;!l!ii !I! ii iI:i
Condensing Units
4TTR4A/B Models
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT -- This Document is customer property and is to remain with this unit. Please return to service information
pack upon completion of work.
These instructions do not cover all variations in
systems nor provide for every possible contingency to
be met in connection with installation. All phases of
this installation must comply with NATIONAL, STATE
AND LOCAL CODES. Should further information be
desired or should particular problems arise which are not
covered sufiieiently for the purchaser's purposes, the matter
should be referred to your installing dealer or local distributor.
A. GENERAL
This information is intended for use by individuals posses-
sing adequate backgrounds of electrical and mechanical
experience. Any attempt to repair a central air conditioning
product may result in personal injury and or property
damage. The manufacturer or seller cannot be responsible
for the interpretation of this information, nor can it assume
any liability in connection with its use.
The following instructions cover 4TFR4 Condensing Units.
NOTE:
These outdoor units are designed to be installed with
approved/matched Trane indoor systems.
These units use R-410A refrigerant which operates at 50 to
70% higher pressures than R-22. Use only R-410A approved
service equipment. Refrigerant cylinders are painted a
"Rose" color to indicate the type of refrigerant and may
contain a "dip" tube to allow for charging of liquid refriger-
ant into the system. All R-410A systems use a POE oil that
readily absorbs moisture from the atmosphere. To limit this
"hygroscopic" action, the system should remain sealed
whenever possible. Never break a vacuum with air and
always change the driers when opening the system for
component replacement.
Check for transportation damage after unit is uncrated.
Report promptly, to the carrier, any damage found to the unit.
To determine the electrical power requirements of the unit,
refer to the nameplate of the unit. The electrical power
available must agree with that listed on the nameplate.
UNiT CONTAINS R-410A REFRIGERANT!
R-410A OPERATING PRESSURE EXCEEDS THE
LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS
REQUIRED. FAILURE TO USE PROPER SERVICE
TOOLS MAY RESULT IN EQUIPMENT DAMAGE OR
PERSONAL INJURY.
SERVICE
USE ONLY R-410A REFRIGERANT AND
APPROVED POE COMPRESSOR OIL.
©5 FT. ABOVE UNiT -- UNRESTRICTED
B. LOCATION AND PREPARATION
OF THE UNiT
1. When removing unit from the pallet, notice the tabs on
the basepan. Remove tabs by cutting with a sharp tool as
shown in Figure 2 (see page 2).
2. The unit should be set on a level support pad at least as
large as the unit base pan, such as a concrete slab. If this
is not the application used please refer to application
bulletin "Trane XR-APG**-EN". (*denotes latest
revision number)
|nstaI|er's Guide
@BASEPAN TAB REMOVAL NOTE:
Attach R-410A CAUTION Label (located in documentation
package) to access panel of indoor section.
IMPORTANT:
The outdoor unit is shipped withthe proper size orifice and a
stick-on orifice size label in an envelope attached to the outdoor
unit. Outdoor unit nameplate will have correct orifice size
specified as BA YFCCV---A for rated pefformance.
D. iNSTALLiNG REFRIGERANT LINES
3. The support pad must NOT be in direct contact with any
structure. Unit must be positioned a minimum of 12"
from any wall or surrounding shrubbery to insure
adequate airflow. Clearance must be provided in ff'ont of
control box (access panels) & any other side requiring
service access to meet National Electrical Code. Also,
the unit location must be fhr enough away from any
structure to prevent excess roof run-off water from
pouring directly on the unit. Do not locate unit(s) close
to bedroom(s).
4. The top discharge area must be unrestricted fbr at least
five (5) feet above the unit.
5. When the outdoor unit is mounted on a roof! be sure the
roof will support the unit's weight. Properly selected
isolation is recommended to prevent sound or vibration
transmission to the building structure.
6. The maximum length of refrigerant lines ff'om outdoor to
indoor unit should NOT exceed sixty (60) feet.
7. If outdoor unit is mounted above the air handler, maxi-
mum lift should not exceed sixty (60) feet (suction line).
If air handler is mounted above condensing unit, maxi-
mmn lift should not exceed sixty (60) feet (liquid line).
NOTE:
Refer to "Refrigerant Piping Software" Pub. No. 32-3312-02.
8. Locate and install indoor coil or air handler in accor-
dance with instruction included with that unit.
C. ACCUTRON TM FLOW CONTROL VALVE
If the indoor unit System Refrigerant Flow control is an
Aecutron TM orifice and check valve assembly, an orifice size
change may be necessary.
The outdoor model determines the required orifice size.
Check the listed orifice size on nameplate of the selected
outdoor model. If the indoor unit is fhctory shipped with a
diffbrent orifice size, the orifice must be changed to obtain
system rated perfbrmance.
BRAZE TYPE iNDOOR END
SEALING CAP
If using existing refrigerant lines make certain that all joints
are brazed, not soldered.
Condensing units have provisions for braze connections.
Pressure taps are provided on the service valves of outdoor
unit fbr compressor suction and liquid pressures.
The indoor end of the recommended refrigerant line sets may
be straight or with a 90 degree bend, depending upon situa-
tion requirements. This should be thoroughly checked out
befbre ordering refrigerant line sets.
The gas line must always be insulated.
in scroll compressor applications, dome temperatures may
be hot. Do not touch top of compressor, may cause minor
to severe burning.
The units are fhctory charged with the system charge
required when using fifteen (15) feet of connecting line. Unit
nameplate charge is the same.
Final refrigerant charge adjustment is necessary. Use
the Charging Charts in the outdoor unit Service Facts.
1. Determine the most practical way to run the lines.
2. Consider types of bends to be made and space limitations.
NOTE:
Large diameter tubing will be very difficult to rebend once it
has been shaped.
3. Determine the best starting point for routing the refriger-
ant tubing -- INSIDE OR OUTSIDE THE STRUCTURE.
4. Provide a pull-thru hole of sufficient size to allow both
liquid and gas lines.
5. Be sure the tubing is of sufficient length.
6. Uncoil the tubing -- do not kink or dent.
7. Route the tubing making all required bends and properly
secure the tubing betbre making connections.
8. To prevent a noise within the building structure due to
vibration transmission from the reff'igerant lines, the
tbllowing precautions should be taken:
a. When the refrigerant lines have to be thstened to floor
joists or other ff'aming in a structure, use isolation
type hangers.
b. Isolation hangers should also be used when reff'iger-
ant lines are run in stud spaces or enclosed ceilings.
c. Where the reff'igerant lines run through a wall or sill,
they should be insulated and isolated.
d. Isolate the lines from all ductwork.
© 2008 American Standard Heating & Air Conditioning 18-AC51 D6-1
|nsta||er's Guide
©LiQUiD LiNE SERVICE VALVE
ROLLED EDGE TO
KF'_.._/ / CAPTIVATESTEM
CAP
sE.%"Ic"s,DEoF .EXRE%%
SERVICE _ k_,Y /
PORT -- /
LIQUID LINE
CONNECTION
E. SERVICE VALVE OPERATION
BRASS LIQUID LINE SERVICE VALVE
The Brass Liquid Line Service Valve is thetory shipped in the
seated position to hold thctory charge. The pressure tap
service port (when depressed) opens only to the field brazing
side of the valve when the valve is in the seated position.
The liquid line valve is not a back seating valve (see
WARNING below).
LEAK CHECK
iMPORTANT:
Replace pressure tap port valve core before attaching hoses
for evacuation.
After the brazing operation of refrigerant lines to both the
outdoor and indoor unit is completed, the field brazed
connections must be checked for leaks. Pressurize through
the service valve ports, the indoor unit and field refrigerant
lines with dry nitrogen to 350-400 psi. Use soap bubbles or
other leak-checking methods to see that all field joints are
leak-fi'ee! If not, release pressure; then repair!
SYSTEM EVACUATION
NOTE:
Since the outdoor unit has arefrigerant charge, the gas and
liquid line valves must remain closed.
1. Upon completion of leak check, evacuate the refrigerant
lines and indoor coil before opening the gas and liquid
line valves.
2. Attach appropriate hoses from manifold gauge to gas
and liquid line pressure taps.
Extreme caution should be exercised when opening the
Liquid Line Service Valve. Turn valve stem counterclock-
wise only until the stem contacts the rolled edge. (See
Figure 4) No torque is required.
BRASS GAS LINE SERVICE VALVE
The Brass Gas Line Service Valve is shipped in the closed
position to hold the rectory refrigerant charge. The pressure
tap service port (when depressed) opens only to the field
brazing side when the valve is in the closed position. The Gas
Line Service Valve is full open with a 1/4 turn. See Figure 5.
BRAZING REFRIGERANT LINES
1. Remove lower access cover to access service valves.
2. Before brazing, remove plugs from external copper stub
tubes. Clean internal and external surIhces of stub
tubes prior to brazing.
3. Cut and fit tubing, minimizing the use of sharp
90 ° bends.
4. Insulate the entire gas line and its fittings.
5. Do NOT allow uninsulated liquid line to come in direct
contact with bare gas line.
6. Precautions should be taken to avoid heat damage
to the pressure tap valve core during brazing. It is
recommended that the pressure tap port valve
core be removed and a wet rag wrapped around
the valve body.
NOTICE:
Use care to make sure that no moisture enters pressure tap
port, while wet rag is being used.
NOTICE:
Precautions should be taken to avoid heat damage to
basepan during brazing. It is recommended to keep the
flame directly off of the baeepan.
7. Use a Dry Nitrogen Puige and Brazing Alloy without flux
when brazing the field line to the copper thctory connec-
tion. Flow dry nitrogen into either valve pressure tap
port, thru the tubing and out the other port while brazing.
8. Braze using accepted good brazing techniques.
NOTE:
Unnecessary switching of hoses can be avoided and
complete evacuation of all lines leading to sealed system
can be accomplished with manifold center hose and
connecting branch hose to a cylinder of R-410A and
vacuum pump.
3. Attach center hose of manifold gauges to vacuum pump.
4. Evacuate until the micron gauge reads no higher than
350 microns.
5. Close offvalve to vacuum pump and observe the micron
gauge. If gauge pressure rises above 500 microns in one (1)
minute, then evacuation is incomplete or system has a leak.
6. If vacuum gauge does not rise above 500 microns in
one (1) minute, the evacuation should be complete.
7. With vacuum pump and micron gauge blanked off, open
valve on R-410A cylinder and charge refrigerant lines and
indoor coil with vapor to tank pressure of R-410A supply.
NOTE:
DO NOT VENT REFRIGERANT INTO THE ATMOSPHERE.
8. Close valve on R-410A supply cylinder. Close valves on
manifold gauge set and remove refioigerant charging
hoses from liquid and gas pressure tap ports.
@GAS LiNE SERVICE VALVE
c,P_ ,%,%,27L,_.....
FOR FULL OPEN
UN,TS,OE/!_ TM
oP VALVE
PRESSURE TAP PORT /#
/
GAS LINE CONNECTION
18-AC51 D6-1
|nsta||er's Guide
NOTE:
A 3/16" Allen wrench is required to open liquid line service
valve. A I/4" Open End or Adjustable wrench is required to
open gas line valve. A 3/4" Open End wrench is required to
take off the valve stem cap.
9. The liquid line shut-offvalve can now be opened. Remove
shut-off valve cap. Fully insert hex wrench into the stem
and backout counterclockwise until valve stem just touches
rolled edge (approximately five [5] turns) observing
WARNING statement on page 3. See Figure 4.
10. Replace liquid service pressure tap port cap and valve
stem cap. These caps MUST BE REPLACED to
prevent leaks. Replace valve stein cap and pressure tap
cap finger tight, then tighten an additional 1/6 turn.
11. The gas valve can now be opened. Open the gas valve by
removing the shut-off valve cap and turning the valve
stem 1/4 turn eounterelockwise, using 1/4" Open End or
Adjustable wrench. See Figure 5.
12. The gas valve is now open for refl'igerant flow. Replace
valve stem cap to prevent leaks. Again, these caps
MUST BE REPLACED to prevent leaks. Replace valve
stem cap and pressure tap cap finger tight, then tighten
an additional 1/6 turn. See Figure 5.
If refl'igerant lines are longer than 15 feet and!or a
diff>rent size than recommended, it will be necessary to
adjust system refl'igerant charge upon completion of
installation. See unit Service Facts.
F. ELECTRICAL CONNECTIONS
When installing or servicing this equipment, ALWAYS
exercise basic safety precautions to avoid the possibility of
electric shock.
1. Power wiring and _'ounding of equipment must comply
with local codes.
2. Power supply must agree with equipment nameplate.
3. Install a separate disconnect switch at the outdoor unit.
4. Ground the outdoor unit per local code requirements.
5. Provide flexible electrical conduit whenever vibration
transmission may create a noise problem within the
structure.
6. The use of color coded low voltage wire is recommended
to simplify connections between the outdoor unit, the
thermostat and the indoor unit.
Table I-- NEC Class II Control Wiring
24 VOLTS
WIRE SIZE MAX. WIRE LENGTH
18 AWG 150 FT
16 AWG 225 FT.
14 AWG 300 FT.
7. Table 1 defines maximum tota! length of low voltage
wiring from outdoor unit, to indoor unit, and to thermostat.
8. Mount the indoor thermostat in accordance with instruc-
tion included with the thermostat. Wire per appropriate
hook-up diagram (included in these instructions).
G. COMPRESSOR START UP
After all electrical wiring is complete, SET THE THERMO-
STAT SYSTEM SWITCH IN THE OFF POSITION SO
COMPRESSOR WILL NOT RUN, and apply power by
closing the system main disconnect switch. This will activate
the compressor sump heat (where used). Do not change the
Thermostat System Switch until power has been applied for
one (1) hour. Following this procedure will prevent potential
compressor overload trip at the initial start-up.
H. OPERATIONAL AND
CHECKOUT PROCEDURES
Final phases of' this installation are the unit Operational and
Checkout Procedures which are found in this instruction (see
page 8). To obtain proper performance, all units must be
operated and charge adjustments made in accordance with
procedures found in the Service Facts.
I. ELECTRIC HEATERS
Electric heaters, if used, are to be installed in the air han-
dling device according to the instructions accompanying the
air handler and the heaters.
d. START CONTROL
Some models have quick start components which are fhctory
installed. For models that do not have fhctory installed start
components, provisions are made for a field installed start kit
accessory. When adding an accessory, follow the instructions
provided with the kit.
K. OUTDOOR THERMOSTAT
An outdoor thermostat TAYSTAT250B may be field installed.
For data, see wiring diagram attached to unit and instruction
sheet packaged with outdoor thermostat.
L. SEACOAST SHIELD
Units installed within one mile of salt water, including
seacoasts and inland waterways, require the addition of
BAYSEAC001 (Seacoast Kit) at the time of installation.
IMPORTANT:
See Limited Warranty information in Use and Care Manual
M. TROUBLESHOOTING
TROUBLESHOOTING CHART -- WHAT TO CHECK
SYSTEMFAULTS
REFRIGERANTCIRCUIT
ELECTRICAL
Compressor&OD FanDoNotStart
CompressorWillNotStartButOD FanRuns
OD FanWon'tStart
CompressorNt_msButWon'tStart
CompressorCyclesonIOL
ID BlowerWon'tStart
PPrimaryCauses S Sec0ndaryCauses
4 18-AC51 D6-1
|nsta||er's Guide
TYPICAL FIELD HOOK=UP DIAGRAMS
T'STAT IR HANDLER
...... R
...... Wl
A I CONDITIONER
...... y
ODT
_ ...... B
VARIABLE SPEED
T'STAT AIR HANDLER AIR CONDITIONER
F_q
FTq
1233
ISTq
_"= === y
0DT A
JoP_,O...... o_ i
'"B
PRINTEDFROM B152901P02 PRINTED FROMBI52gosP03
÷ CONNECTIONSTO BE MADE FOR OPERATION OF
BLOWERWITH HUMIDISTAT IN COOLING
T 'STAT
Fq
E3
E3
Fq
Fq
NOTE
I -STAGE
OR
2-STAGE
FURNACE
E3
E3
Fcl
F8
Fq
AI CONDITIONER
_. ..... y
...... B
PRINTEDFROMB152903P02
-kW2 present only on 2 stage
thermostat and furnace
Notes:
1. Be sure power supply agrees with equipment nameplate.
2. Power wiring and grounding of equipment must comply with local codes.
3. Low voltage wiring to be No. 18 AWG minimum conductor.
4. ODT-B must be set lower than ODT-A.
5. If outdoor thermostats (ODT) are not used, connect W1 to W2 and W3.
T 'STAT
E3
Fq
E3
] NOTE
Fq
PRI NTE
VARIABLE SPEED
2 STAGE FURNACE
r_
i-tS]]
Frl
[]
prl
E]
Fq
FRO BI52901P04
LEGEND
..... FACTORY WIRING
_ FIELD WIRING
AI CONDITIONER
_-.-y
18-AC51 D6-1 5
|nstaller's Guide
4TTR4 OUTLINE DRAWING
NOTE: ALL DIMENSIONSARE IN MM (INCHES).
c
SERVICE PANEL....................
ELECTRICAL AND REFRIGERANT
COMPONENTCLEARANCES
PER PREVAILING CODES
TOP DISCHARGE AREA SHOULD BE
UNRESTRICTED FOR AT LEAST 1524 {5 FEET)
ABOVE UNIT UNIT SHOULDBE PLACED SO ROOF
RUN OFF WATER DOEB NOT POUR DIRECTLY ON UNIT,
AND SHOULDBE AT LEAST 305 {IR"/ FROM WALL AND
ALL SURROUNDINGSHRUBBERYON TWOSIDES
OTHER TWOSIDES UNRESTRICTED
K
ELECTRICAL SERVICE -_
PANEL
222 (7/8) DIA
LOWVOLTAGE
286 (I I/8) DIA KO
222 (7/8) DIA HOLE IN CONTROL
BOX BOTTOMFOR ELECTRICAL
POWERSUPPLY
LIOUID LINE SERVICE VALVE
IIEII ID FEMALE BRAZE
CONNECTIONWITH I/4 II SAE
FLARE PRESSURETAP FITTINGS
IbI' _ ,
//./I \ _ k_\
FIG.1
FOR ALTERNATE
_} ELECTRICAL ROUTING
AS LINE I/4 TURN BALL SERVICE VALVE, "D"
ID FEMALE BRAZED CONNECTION WITH I/4" SAE
FLARE PRESSURE TAP FITTING
MODELS
4TTR4018B
4TTR4024B
4TTR4030A
4TTR4036A
4TTR4042A
4TTR4048A
4TTR4060B
BASE
3
3
3
3
4
4
4
FIG.
1
1
1
1
1
1
1
A
832 (32-3/4)
832 (32-3/4)
832 (32-3/4)
933 (36-3/4)
943 (37-1/8)
1045 (41-1/8)
1045 (41-1/8)
B
829 (32-5/8)
829 (32-5/8)
829 (32-5/8)
829 (32-5/8)
946 (37-1/4)
946 (37-1/4)
946 (37-1/4)
C D E F G H J K
756 (29-3/4) 1/2 1/4 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)
756 (29-3/4) 5/8 5/16 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)
756 (29-3/4) 3/4 5/16 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)
756 (29-3/4) 3/4 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)
870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20)
870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20)
870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20)
6 18-AC51 D6-1
Insialler's Guide
MOUNTING HOLE LOCATION
NOTE: ALL DIMENSIONS ARE IN MM (INCHES).
294 (11 56)_ 1
Ill (6 14)
DRILL4 PLACES
335 (1319)
(2709)
221 (8,69)
NOTE: For model base size,
see table on page 6.
310 (12 20)_
'99 (23 bS)
' ( 2{i 6 'i )
BASE 4
158 (624)
_I)RILL
f 4 PLACES
9'
717 (2824)
(31 s_8)
From Dwg. D152637 Rev. 1
18-AC51 D6-1 7
|nsta||er's Guide
CHECKOUT PROCEDURE
After installation has been completed, it is recommended that the entire system be checked against the following list:
1. Refrigerant Line, Leak checked .................................. [
2. Suction Lines and Fittings properly insulated ........... [
3. Have all Refi'igerant Lines been secured and
isolated properly? ........................................................ [
4. Have passages through masonry been sealed?
If mortar is used, prevent mortar from coming
into direct contact with copper tubing ........................ [
5. Verify tightness of all electrical connects ................... [
6. Observe outdoor fhn during on cycle for clearance
and smooth operation .................................................. [
7. Indoor coil drain line drains freely. Pour water
into drain pan .............................................................. [
] 8. Supply registers and return _'illes open and
] unobstructed ................................................................ [ ]
9. Return air filter installed ............................................ [ ]
] 10. Thermostat thermometer is accurate. Check
against a reliable thermometer. Adjust per
instructions with thermostat ...................................... [ ]
] 11. Is correct speed tap being used?
] (Indoor blower motor) .................................................. [ ]
12. Operate complete system in each mode to
insure safe operation ................................................... [ ]
CHECKOUT PROCEDURE WiTH MAiN P(
Step
No. TO CHECK
1 SumpHeat
2 IndoorFan Operation
3 CoolingOperation
4 CheckingPerformance
& Charge
5 Heating@
6
Off
iNDOORTHERMOSTAT
SWITCHSETTING
@ @ FanSwitch
Cool Heat Auto On
X X
)WER DISCONNECTS CLOSED (ON)
COMPONENTOPERATION
indoor Outdoor
Blower Fan
Runs Runs
Compressor @ Comp. Furnace
Runs Sump Heat
Heater Comes On
X
X
X
X
X
X
X X X X
x Ix I x I x x
USE CHARTS ATTACHED TO O.D. UNIT
Informowner on howto operatesystem andwhat to expectof it. At the sametimedeliverOwner'sUseand CareBooklet.
@ Also set thermostat dial to call for cooling or heating as necessary.
@ Check only necessary if heating unit is used for indoor section and wiring has been disturbed during installation of cooling equipment,
@ When applicable.
ARI Standard
210/240 UAC
05/08
1r]MN£
Trane
www.trane.com
Trane has a policy of continuous product and product data improvement and it reserves the right to change
design and specifications without notice.