TRANE Air Conditioner/heat Pump(outside Unit) Manual L0905065
User Manual: TRANE TRANE Air conditioner/heat pump(outside unit) Manual TRANE Air conditioner/heat pump(outside unit) Owner's Manual, TRANE Air conditioner/heat pump(outside unit) installation guides
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
2TWR2-1N-1B 18-BC51D2-3 Pumps 2TWR1 & 2TWR2 ALL phases of this installation IMPORTANT -- This Document pack upon completion of work. must comply is customer with NATIONAL, property STATE and is to remain These instructions do not cover all variations in systems nor provide for every possible contingency to be met in connection with installation. All phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's purposes, the matter should be referred to your installing dealer or local distributor. © AND LOCAL with this unit. CODES Please return to service information 5 FT. ABOVE UNIT-UNRESTRICTED A. GENERAL The following instructions Pump Units. cover 2TWR1 and 2TWR2 Heat NOTE: These outdoor units may be used with indoor units equipped with Thermostatic Expansion Valve or Accutron rM Flow Control Check Valve (F.C.C.V.) assembly for refrigerant flow control only. Check for transportation damage after unit is uncrated. Report promptly, to the carrier, any damage found to the unit. To determine the electrical power requirements of the unit, refer to the nameplate of the unit. The electrical power available must agree with that listed on the nameplate. The Weathertron ®Heat Pump has been designed and manufactured to withstand and operate in severe winter conditions. However, there are precautionary steps which should be taken at the time of installation which -will help assure the efficient operation of the unit. It is recommended that these precautions be taken for units being installed in areas where snow accumulation and prolonged below freezing temperatures occur. 1, Units should be elevated 3 to 12 inches above the pad or rooftop, depending on local weather. This additional height will allow better drainage of snow and ice (melted during defrost cycle) prior to its refreezing. This should prevent a build-up of ice around the unit which occurs when unit is not elevated. Insure that drain holes in unit base pan are not obstructed preventing draining of defrost water. 2. If possible, avoid locations that are likely to accumulate snow drifts. If not possible, a snow drift barrier should be installed around the unit to prevent a build-up of snow on the sides of the unit and should be of sufficient distance from the unit to prevent restriction of airflow to and from the unit. Also allow for proper maintenance space. The barrier should be constructed of materials which will blend in with the building design. 3, Avoid locating the unit where condensation and freezing of defrost vapor may annoy the customer. For instance, installing the unit under a bedroom, ldtchen, or picture window may be annoying to the customer since condensate and fog will occur during the defrost cycle. 4, Avoid locating the unit under the eaves or other overhead structures as sizeable icicles may form and the unit may be damaged by these falling icicles. B. LOCATION AND PREPARATION OFTHE UNIT 1. When removing unit from the pallet, notice the tabs on the basepan. Remove tabs by cutting with a sharp tool as shown on page 2, Figure 2, and slide unit off of pallet. 2, The unit should be set on a level support pad at least as large as the unit base pan, such as a concrete slab. If this is not the application used please refer to application bulletin "Trane APB2001-02". 3, The support pad must NOT be in direct contact with any structure. Unit must be positioned a minimum of 12" from any wall or surrounding shrubbery to insure adequate airflow. Clearance must be provided in front of control box (access panels) and any other side requiring service access to meet National Electrical Code. Also, the unit location must be far enough away from any struc- |nsta||er's @ Guide BASEPAN D. INSTALLING TAB REMOVAL REFRIGERANT If using existing refrigerant are brazed, not soldered. Condensing LINES lines make certain that all joints units have provisions for braze connections. Pressure taps are provided on the service valves of outdoor unit for compressor suction and liquid pressures. ture to prevent excess roof run-off water from pouring directly on the unit. Do not locate unit(s) close to bedroom(s). 4. The top discharge area must be unrestricted five (5) feet above the unit. 6. The maximum length of refrigerant lines from outdoor to indoor unit should NOT exceed sixty (60) feet. 7. If outdoor unit is mounted above the air handler, maximum lift should not exceed sixty (60) feet (suction line). If air handler is mounted above condensing unit, maximum lift should not exceed sixty (60) feet (liquid line). 8. Locate and install indoor coil or air handler in accordance with instruction included with that unit. TM FLOW CONTROL VALVE If the indoor unit System Refrigerant Flow control is an Accutron TM orifice and check valve assembly, an orifice size change may be necessary. The outdoor model determines the required orifice size. Check the listed orifice size on nameplate of the selected outdoor model. If the indoor unit is factory shipped with a diffhrent orifice size, the orifice must be changed to obtain system rated performance. IMPORTANT'. The outdoor unit is shipped with the proper size orifice and a stick-on orifice size label in an envelope attached to the outdoor unit. Outdoor unit nameplate will have correct orifice size specified as BAYFCCV --- A for rated performance. BRAZE TYPE iNDOOR The gas line must always be insulated. for at least 5. When the outdoor unit is mounted on a roof, be sure the roof will support the unit's weight. Properly selected isolation is recommended to prevent transmission to the building structure. C. ACCUTRON The indoor end of the recommended refrigerant line sets may be straight or with a 90 degree bend, depending upon situation requirements. This should be thoroughly checked out before ordering refrigerant line sets. In scroll compressor applications, dome temperatures may be hot. Do not touch top of compressor, may cause minor to severe burning. The units are factory charged with the system charge required -when using fifteen (15) f_et of connecting line. Unit nameplate charge is the same. Final refrigerant charge adjustment is necessary. the Charging Charts in the outdoor unit Service Facts. 1. Determine 2. Consider the most practical Use way to run the lines. types of bends to be made and space limitations. NOTE: Large diameter tubing will be very difficult to rebend once it has been shaped. 3, Determine ant tubing the best starting point for routing the refriger- -INSIDE OR OUTSIDE THE STRUCTURE. 4. Provide a pull-thru hole of sufficient liquid and gas lines. 5. Be sure the tubing is of sufficient 6. Uncoil the tubing size to allow both length. --- do not kink or dent. 7. Route the tubing making all required bends and properly secure the tubing before making connections. 8. To prevent a noise within the building structure due to vibration transmission from the refrigerant lines, the following precautions should be taken: a. When the refrigerant lines have to be fastened to floor joists or other framing in a structure, use isolation type hangers. END SEALING CAP LiQUiD LiNE SERVICE VALVE ROLLED CAP_ @ EDGE TO CAPTIVATE / STEM sEO.ffS ,S'DEOF ---- .EX.EADgEM SERVICE PORT _ _ / -- / LIQUID LINE CONNECTION © 2002 American Standard Inc. All Rights Reserved 18-BC51 D2-3 |nsta||er's @ ® GAS LiNE BALL SERVICE VALVE Guide GAS LiNE SERVICE VALVE ROLLED CAP ---__ ,I-J, 1/4 TURN ONLY COUNTERCLOCKWISE FOR FULL OPEN I _ CAP_ @ / EDGE TO CAPTIVATE STEM POSITION VALVEBTEM HEXHEADED VALVE SYSTEM UNIT SIDE OF UNITSIDE OFVALVE SERVICE VALVE SERVICE-_q PRESSURETAPPORT / GAS LINE CONNECTION PORT / GASLINE CONNECTION o,. CAP _ 6. Precautions should be taken to avoid heat damage to the pressure tap valve core during brazing. It is recommended that the pressure tap port valve core be removed and a wet rag wrapped around the valve body. (_ COOL L_ZI i BODY _ NOTE: Use care to make sure that no moisture port, while wet rag is being used. 17_ q CORE b. Isolation hangers should also be used -when refrigerant lines are run in stud spaces or enclosed ceilings. c. Where the refrigerant lines run through they should be insulated and isolated. d. Isolate a wall or sill, the lines from all ductwork. E. SERVICE VALVE OPERATION enters pressure NOTE: Precautions should be taken to avoid heat damage to basepan during brazing. It is recommended to keep the flame directly off of the basepan. 7. Use a Dry Nitrogen Purge and Brazing Alloy without flux when brazing the field line to the copper thctory connection. Flow dry nitrogen into either valve pressure tap port, thru the tubing and out the other port while brazing. BRASS LIQUID AND GAS LINE SERVICE VALVES The Brass Liquid and Gas Line Service Valves are factory shipped in the seated position to hold factory charge. The pressure tap service port (when depressed) opens only to the field brazing side of the valve when the valve is in the seated position. The liquid line valve is not a back seating valve (see WARNING below). LEAK CHECK Extreme caution should be exercised when opening the Liquid and Gas Line Service Valves. Turn valve stem counterclockwise only until the stem contacts the roiled edge. (See Figures 4 and 6) No torque is required. After the brazing operation of refrigerant lines to both the outdoor and indoor unit is completed, the field brazed connections must be checked for leaks. Pressurize through the service valve ports, the indoor unit and field refrigerant lines with dry nitrogen to 350-400 psi. Use soap bubbles or other leak-checking methods to see that all field joints are leak-free! If not, release pressure; then repair! BRASS GAS LINE BALL SERVICE VALVE The Brass Gas Line Service Valve is shipped in the closed position to hold the factory refrigerant charge. The pressure tap service port (when depressed) opens only to the field brazing side when the valve is in the closed position. The Gas Line Service Valve is full open with a 1/4 turn. Figure 5. 3. Cut and fit tubing, minimizing 4. Insulate 18-BC51 D2-3 copper stub of stub tubes the use of sharp 90 ° bends. the entire gas line and its fittings. 5. Do NOT allow uninsulated contact with bare gas line. 8. Braze using accepted good brazing techniques. IMPORTANT: Replace pressure tap port valve core before attaching hoses for evacuation. SYSTEM EVACUATION NOTE: Since the outdoor unit has a refrigerant liquid line valves must remain closed. charge, the gas and See BRAZING REFRIGERANT LINES 1. Remove lower access cover to access service valves. 2. Before brazing, remove plugs from external tubes. Clean internal and external surfaces prior to brazing. tap liquid line to come in direct 1. Upon completion lines and indoor line valves. of leak check, evacuate the refrigerant coil before opening the gas and liquid 2. Attach appropriate hoses from manifold and liquid line pressure taps. gauge to gas NOTE: Unnecessary switching of hoses can be avoided and corn= plete evacuation of all lines leading to sealed system can be accomplished with manifold center hose and connecting branch hose to a cylinder of HCFC-22 and vacuum pump. 3 |nstaI|er's 3. Attach center 4. Evacuate until 350 microns. Guide hose the of manifold micron gauges gauge to vacuum reads no higher pump. than 5. Close offvalve to vacuum pump and observe the micron gauge. If gauge pressure rises above 500 microns in one (1) minute, then evacuation is incomplete or system has a leak. 6. If vacuum gauge does not rise above 500 microns (1) minute, the evacuation should be complete. 5. Provide flexible electrical conduit whenever vibration transmission may create a noise problem within the structure. 6. The use of color coded low voltage wire is recommended to simplify connections between the outdoor unit, the thermostat and the indoor unit. Table 1 --- NEC Class II Control Wiring in one 24 VOLTS 7. With vacuum pump and micron gauge blanked off; open valve on HCFC-22 cylinder and charge refrigerant lines and indoor coil with vapor to tank pressure of HCFC-22 supply. NOTE: DO NOT VENT REFRIGERANT INTO THE ATMOSPHERE. 8. Close valve on HCFC-22 supply cylinder. Close valves on manifold gauge set and remove refrigerant charging hoses from liquid and gas pressure tap ports. NOTE: A 3/16" Allen wrench is required to open liquid line service valve. A 1/4" Open End or Adjustable wrench is required to open gas line valve. A 3/4" Open End wrench is required to take off the valve stem cap. 9. The liquid line shut-offvalve ean now be opened. Remove shut-offvalve cap. Fully insert hex wrench into the stem and backout counterclockwise until valve stem just touches rolled edge (approximately five [5] turns) observing WARNING statement on page 3. See Figure 4. 10. Replace liquid service pressure tap port cap and valve stem eap. These caps MUST BE REPLACED to prevent leaks. Replace valve stem and pressure tap cap finger tight, then tighten an additional 1/6 turn. 11. The gas valve can now be opened. For a ball type gas valve, open the gas valve by removing the shut-offvalve cap and turning the valve stem 1/4 turn counterclockwise, using 1/4" Open End or Adjustable wrench. See Figure 5. For brass gas line service valve opening, follow 9 and 10 above. See Figure 6. 12. The gas valve is now open for refrigerant flow. Replace valve stein cap to prevent leaks. Again, these eaps MUST BE REPLACED to prevent leaks. Replace valve stem and pressure tap cap finger tight, then tighten an additional 1/6 turn. See Figure 4. If refrigerant lines are longer than 15 feet and/or a difi_rent size than recommended, it will be necessary to adjust system refrigerant charge upon completion of installation. See unit Service Facts. F. ELECTRICAL WIRE SIZE 7. 8. LENGTH 18 AWG 150 FT 16 AWG 225 FT. 14 AWG 300 FT. Table 1 defines maximum total length of low voltage wiring from outdoor unit, to indoor unit, and to thermostat. Mount the indoor thermostat in accordance with instruction included -with the thermostat. Wire per appropriate hook-up diagram (included in these instructions). G. DEFROST CONTROL The demand defrost control measures heat pump outdoor ambient temperature with a sensor located outside the outdoor coil. A second sensor located on the outdoor coil is used to measure the coil temperature. The diffhrence between the ambient and the colder coil temperature is the diffhrence or delta-T measurement. This delta-T measurement is representative of the operating state and relative capacity of the heat pump system. By measuring the change in delta-T, we can determine the need for defrost. The coil sensor also serves to sense outdoor coil temperature for termination of the defrost cycle. FAULT iDENTiFICATiON A fault condition is indicated by the flashing light on the defrost control inside the heat pump control box. In normal operation, the defrost control light will flash once each second. If the light is flashing more than once per second or not at all, refer to the service manual for that unit. PiN iDENTiFiCATiON (See Figure 7.) 1. TEST_COMMON (Shorting any of the other pins to this pin causes the function of the other pin to be executed. Leaving this pin open results in the normal mode of operation.) 2. TST = Test (Shorting TEST_COMMON speeds up all defrost board timings.) © CONNECTIONS MAX. WIRE to this pin PiN iDENTiFiCATiON Z 0 When installing or servicing this equipment, ALWAYS exercise basic safety precautions to avoid the possibility of electric shock. 1. Power -wiring and grounding with local codes. of equipment 2. Power supply must agree with equipment o o must comply nameplate. LL 3. Install 4. Ground 4 a separate the outdoor disconnect switch at the outdoor unit per local code requirements. unit. ° m LL I \ p- 18-BC51 D2-3 |nsta||er's 3. FRC_DFT = Forced Defrost (Short TEST_COMMON this pin for two (2) seconds to initiate a forced defrost. Remove the short after defrost initiates.) to DEFROST CONTROL CHECKOUT Normal operation requires: a. LED on board flashing 1 time/second. b. 24V AC between R & B c. 24V AC between Y & B with unit operating d. Defrost initiation TEST_COMMON when FRC_DFT pin. If a defrost control problem is suspected, information in control box. pin is shorted to refer to the service ODS=A AND CHECKOUT Final phases of this installation are the unit Operational and Checkout Procedures which are found in this instruction on page 8. To obtain proper performance, all units must be operated and charge adjustments made in accordance with procedures found in the Service Facts. J. ELECTRIC Do NOT connect 24 VAC to T1 (ODS=A) terminal. thermistor WILL BE BLOWN. H. COMPRESSOR I. OPERATIONAL PROCEDURES Guide HEATERS Electric heaters, if used, are to be installed in the air handling device according to the instructions accompanying the air handler and the heaters. K. START CONTROL Some models have quick start components which are fhctory installed. For models that do not have factory installed start components, provisions are made for a field installed start kit accessory. When adding an accessory, follow the instructions provided with the kit. L. OUTDOOR THERMOSTAT START UP After all electrical wiring is complete, SET THE THERMOSTAT SYSTEM SWITCH IN THE OFF POSITION SO COMPRESSOR WILL NOT RUN, and apply power by closing the system main disconnect switch. This will activate the compressor sump heat (where used). Do not change the Thermostat System Switch until power has been applied for one (1) hour. Following this procedure will prevent potential compressor overload trip at the initial start-up. An outdoor thermostat TAYSTAT250B may be field installed. For data, see wiring diagram attached to unit and instruction sheet packaged with outdoor thermostat. M. SEACOAST SALT SHIELD Units installed -within one mile of salt water including seacoasts and inland waterways, require the addition of BAYSEAC001 (Seacoast Kit) at the time of installation. IMPORTANT: See Limited Warranty information in Use and Care Manual. TYPICAL )iR H,',,I,,D ER T '3T/_T FIELD HOOK=UP DIAGRAMS HF,',,T PU:_4P @ _---'i_ L ... 'S iAR A,i; SP II) ,::, R HA!',[) ER ;, II [/; i ,. i ._,."... 0 i_ R-n , P U_,'I y 0 :iK( X1_) G; ( F!K X2 ) :ii \ I[...,:_ -- _- -- .... .__c.P._9.' _i ._u4o{_. -_ i i i iB; i B } ; i _----_,; ii' ,, L....[_ : [ > l i, r riD ::03 PR i,i F;;' FROM , i :1;'9 )4PO{Z Notes: LEGEND 1. Be sure power supply agrees with equipment nameplate. 2. Power wiring and grounding of equipment must comply with local codes. 3. Low voltage wiring to be No. 18 AWG minimum conductor. 4. ODT-B must be set lower than ODT-A. ,5. If outdoor thermostats (ODT) are not used, connect W1 to W2 and W3. 6. N/A to programmable thermostat. 18-BC51 D2-3 ..... FACTORY WIRING FIELD WIRING 5 Installer's Guide SERViCr PANE[ .......... _ IIICIRiCAI ANI) iRIFIRiG_RA_i COMPONENT C[LARA_C_S PER PREVAilinG CO_LS iOP DiSCiiARGE AREA SiiOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET} A_OVE UN[_ d_lJ ¸ S_IOU[b BE PEACED SO ROOi i!_O[[ ¸ WATE[i _O[S NO] _O_R _I_E¢iL¥ ON UNi] £_i) SHOWi) _i_ A/ JI_ASI¸ 30_ (i_ ¸¸} EROM WA[i ANJ) ALL SORROUNDiNG SHRUBBERY O_ IWO SinES¸ OTFIER TWO Si_[S U_R_STRiCT[_ F A_EL _ L 25 2_ 2 (bS) 7 i_ i011£ .............. I O_i ?9 I &( ( A :J I I(/;I) t [! S _,,' '3 V , ' I t4A BRAZED CO,i!'E,30l WI I _,1 SAE FLARE PRESSUR Ts, P f TT_G j;, . . --- 28 f, ', 1_8} DIA K 0 _l H........ 22 2 7/8} DIA OlE i_ C,91TR,PL BOX tX) I 'C4 [:OH EL E( R ( AL /()W_ i SIJP[ ' _ ..... j j i (;'U [J _[ S R_iC[ ?/_,'E, -''1''_= @ [: HA [ BE{;} H T COr_/ECl }01i /i I /,I SA[ F LARE PRESSURE I_P il IGS j , , I I_ _ i L il FIG. 1 \ KO ,, [OH AiTER_A[E C i IleAl OJ Iq',, G_ \ GAS i iNE I/4 iWiN SAil SIRVICI ID FE_£LE BRAZED CO_N[CTiO_ FiARE PR[SSbR_ TAP FiTTi_6 VAJVL 'l)' _IT_ [/4 ¸¸ SA[ GAS Li:/ ¢ON_[¢[I()_ SIVCE VALVE, x I D FEI_'ALF BRAZED WlTli i/4 '¸ SA[ FLARE i_R[S$[iR_ lAP i¸ il_ iN6 MODELS BASE FIG. A B D E F G H J K 2TWR1018A 2 2 651 (25-5/8) 724 (28-1/2) 651 (25-5/8) 5/8 1/4 127 (5) 57 (2-1/4) 180 (7-1/8) 44 (1-3/4) 457 (18) 2TWR1024A 2 2 651 (25-5/8) 724 (28-1/2) 651 (25-5/8) 3/4 5/16 127 (5) 57 (2-1/4) 180 (7-1/8) 44 (1-3/4) 457 (18) 2TWR1030A 2 2 730 (28-3/4) 724 (28-1/2) 651 (25-5/8) 3/4 5/16 137 (5-3/8) 65 210 57 457 2TWR1036A 2 2 730 (28-3/4) 724 (28-1/2) 651 (25-5/8) 7/8 3/8 137 (5-3/8) 65 (2-5/8) 210 (8-1/4) 57 (2-1/4) 457 (18) 2TWR1042A 3 2 832 (32-3/4) 829 (32-5/8) 756 (29-3/4) 7/8 3/8 137 (5-3/8) 86 (3-3/8) 210 (8-1/4) 79 (3-1/8) 508 (20) 2TWR1048A 3 2 832 (32-3/4 829 (32-5/8) 756 (29-3/4) 1-1/8 3/8 137 (5-3/8) 86 (3-3/8) 210 (8-1/4) 79 (3-1/8) 508 (20) 2TWR1060A 4 1 841 (33-1/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) 2TWR2018A 2 2 651 (25-5/8) 724 (28-1/2) 651 (25-5/8) 5/8 1/4 127 (5) 57 (2-1/4) 180 (7-1/8) 44 (1-3/4) 457 (18) 2TWR2024A 2 2 730 (28-3/4) 724 (28-1/2) 651 (25-5/8) 3/4 5/16 137 (5-3/8) 65 (2-5/8) 210 (8-1/4) 57 (2-1/4) 457 (18) 2TWR2030B 2 2 832 (32-3/4) 724 (28-1/2) 651 (25-5/8) 3/4 5/16 137 (5-3/8) 65 (2-5/8) 210 (8-1/4) 57 (2-1/4) 457 (18) 2TWR2036A 3 1 832 (32-3/4) 829 (32-5/8) 756 (29-3/4) 7/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20) 2TWR2042A 3 1 832 (32-3/4) 829 (32-5/8) 756 (29-3/4) 7/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20) 2TWR2048A 3 1 933 (36-3/4) 829 (32-5/8) 756 (29-3/4) 1-1/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20) 2TWR2060A 4 1 1045 (41-1/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 C 152 (6) (2-5/8) (8-1/4) From 6 Dwg. (2-1/4) 21D152898 (18) (20) Rev. 9 18-BC51 D2-3 |nstal|er's MOUNTING Guide HOLE LOCATION Note: All dimensions are in IVllVl(Inches). BASE 2 BASE 3 NOTE: For model base size, see table on page 6. ........................................................ $99 (255 _?f BASE 4 18-BC51 D2-3 (2864) n_ ...................................................... 4 From Dwg. 21 D152637 Rev. 1 7 |nsta||er's Guide CHECKOUT After installation 1. Refrigerant 2. Suction has been completed, Line, Leak checked Lines and Fittings it is recommended that .................................. properly insulated ........... 3. Have all Refrigerant Lines been secured and isolated properly? ........................................................ ] [ ] [ [ 5. Verify tightness [ connects the entire [ 4. Have passages through masonry been sealed? If mortar is used, prevent mortar from coining into direct contact with copper tubing ........................ of all electrical PROCEDURE ................... 6. Observe outdoor fan during on cycle for clearance and smooth operation ................................................. [ 7. Indoor coil drain line drains freely. Pour water into drain pan .............................................................. [ TROUBLESHOOTING ] ] system be checked against the following list: 8. Supply registers and return grilles open and unobstructed ............................................................... [ ] 9. Return [ ] 10. Thermostat thermometer is accurate. Check against a reliable thermometer. Adjust per instructions with thermostat ...................................... [ ] 11. Is correct speed tap being used? (Indoor blower motor) ................................................. [ ] 12. Operate complete system in each mode to insure safe operation ................................................... [ ] CHART air filter installed ............................................ m WHAT TO CHECK SYSTEM FAULTS REFRIGERANTCIRCUIT Head Pressure Too High Head Pressure Too Low s s P P s s p p SuctionPressureTooHigh SuctionPressureTooLow LiquidBefrig Eloodback(TXV) IELCoil Frostiag ELECTRICAL Compressor& OB Fan Won't Start s s s s CompressorWill Not Start But OD EalqRuns OD FanWon't Start s s ss CompressorHums ButWon't Start ii $ p $ p P P CompressorCycleson I01. IELBlower Won't Start P Ss PP P P DEFROST UnitWon't Initiate Defrost DefrostTerminateson Time Unit Icing Up C - Cooling H - Heating P - PrimaryCauses S - SecondaryCauses "k - 3 PhaseOnly C T J.N£ Trane A business of American Standard Companies www.trane.com Literature Order Number 2TWR2-iN-1B File Number SV-UN-S/SP-2TWR2-1N-1B Supersedes 2TWR2-1N-1A Stocking Location PI Louisville & Webb/Mason-Houston Trane has a policy of continuous product and product data improvement design and specifications without notice. RI. and it reserves the right to change 2/03
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 8 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Wed May 20 04:16:28 2009 Author : Title : Subject :EXIF Metadata provided by EXIF.tools