TRANE Air Conditioner/heat Pump(outside Unit) Manual L0905065
User Manual: TRANE TRANE Air conditioner/heat pump(outside unit) Manual TRANE Air conditioner/heat pump(outside unit) Owner's Manual, TRANE Air conditioner/heat pump(outside unit) installation guides
Open the PDF directly: View PDF .
Page Count: 8
2TWR2-1N-1B
18-BC51D2-3
Pumps
2TWR1 & 2TWR2
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT -- This Document is customer property and is to remain with this unit. Please return to service information
pack upon completion of work.
These instructions do not cover all variations in
systems nor provide for every possible contingency to
be met in connection with installation. All phases of
this installation must comply with NATIONAL, STATE
AND LOCAL CODES. Should further information be
desired or should particular problems arise which are not
covered sufficiently for the purchaser's purposes, the matter
should be referred to your installing dealer or local distributor.
A. GENERAL
The following instructions cover 2TWR1 and 2TWR2 Heat
Pump Units.
NOTE:
These outdoor units may be used with indoor units
equipped with Thermostatic Expansion Valve or Accutron rM
Flow Control Check Valve (F.C.C.V.) assembly for refrigerant
flow control only.
Check for transportation damage after unit is uncrated.
Report promptly, to the carrier, any damage found to the unit.
To determine the electrical power requirements of the unit,
refer to the nameplate of the unit. The electrical power
available must agree with that listed on the nameplate.
The Weathertron ®Heat Pump has been designed and
manufactured to withstand and operate in severe winter
conditions. However, there are precautionary steps which
should be taken at the time of installation which -will help
assure the efficient operation of the unit. It is recom-
mended that these precautions be taken for units
being installed in areas where snow accumulation and
prolonged below freezing temperatures occur.
1, Units should be elevated 3 to 12 inches above the pad or
rooftop, depending on local weather. This additional
height will allow better drainage of snow and ice (melted
during defrost cycle) prior to its refreezing. This should
prevent a build-up of ice around the unit which occurs
when unit is not elevated. Insure that drain holes in
unit base pan are not obstructed preventing
draining of defrost water.
2. If possible, avoid locations that are likely to accumulate
snow drifts. If not possible, a snow drift barrier should be
installed around the unit to prevent a build-up of snow
on the sides of the unit and should be of sufficient
distance from the unit to prevent restriction of airflow to
and from the unit. Also allow for proper maintenance
space. The barrier should be constructed of materials
which will blend in with the building design.
©
3,
4,
5 FT. ABOVE UNIT-UNRESTRICTED
Avoid locating the unit where condensation and freezing
of defrost vapor may annoy the customer. For instance,
installing the unit under a bedroom, ldtchen, or picture
window may be annoying to the customer since conden-
sate and fog will occur during the defrost cycle.
Avoid locating the unit under the eaves or other over-
head structures as sizeable icicles may form and the unit
may be damaged by these falling icicles.
B. LOCATION AND PREPARATION
OFTHE UNIT
1. When removing unit from the pallet, notice the tabs on
the basepan. Remove tabs by cutting with a sharp tool as
shown on page 2, Figure 2, and slide unit off of pallet.
2,
3,
The unit should be set on a level support pad at least as
large as the unit base pan, such as a concrete slab. If this
is not the application used please refer to application
bulletin "Trane APB2001-02".
The support pad must NOT be in direct contact with any
structure. Unit must be positioned a minimum of 12"
from any wall or surrounding shrubbery to insure
adequate airflow. Clearance must be provided in front of
control box (access panels) and any other side requiring
service access to meet National Electrical Code. Also, the
unit location must be far enough away from any struc-
|nsta||er's Guide
@BASEPAN TAB REMOVAL
ture to prevent excess roof run-off water from pouring
directly on the unit. Do not locate unit(s) close to
bedroom(s).
4. The top discharge area must be unrestricted for at least
five (5) feet above the unit.
5. When the outdoor unit is mounted on a roof, be sure the
roof will support the unit's weight. Properly selected
isolation is recommended to prevent transmission to the
building structure.
6. The maximum length of refrigerant lines from outdoor
to indoor unit should NOT exceed sixty (60) feet.
7. If outdoor unit is mounted above the air handler, maxi-
mum lift should not exceed sixty (60) feet (suction line). If
air handler is mounted above condensing unit, maxi-
mum lift should not exceed sixty (60) feet (liquid line).
8. Locate and install indoor coil or air handler in accor-
dance with instruction included with that unit.
C. ACCUTRON TM FLOW CONTROL VALVE
If the indoor unit System Refrigerant Flow control is an
Accutron TM orifice and check valve assembly, an orifice size
change may be necessary.
The outdoor model determines the required orifice size.
Check the listed orifice size on nameplate of the selected
outdoor model. If the indoor unit is factory shipped with a
diffhrent orifice size, the orifice must be changed to obtain
system rated performance.
IMPORTANT'.
The outdoor unit is shipped with the proper size orifice and a
stick-on orifice size label in an envelope attached to the
outdoor unit. Outdoor unit nameplate will have correct orifice
size specified as BAYFCCV --- A for rated performance.
BRAZE TYPE iNDOOR END
SEALING CAP
D. INSTALLING REFRIGERANT LINES
If using existing refrigerant lines make certain that all joints
are brazed, not soldered.
Condensing units have provisions for braze connections.
Pressure taps are provided on the service valves of outdoor
unit for compressor suction and liquid pressures.
The indoor end of the recommended refrigerant line sets may
be straight or with a 90 degree bend, depending upon
situation requirements. This should be thoroughly checked
out before ordering refrigerant line sets.
The gas line must always be insulated.
In scroll compressor applications, dome temperatures may
be hot. Do not touch top of compressor, may cause minor to
severe burning.
The units are factory charged with the system charge re-
quired -when using fifteen (15) f_et of connecting line. Unit
nameplate charge is the same.
Final refrigerant charge adjustment is necessary. Use
the Charging Charts in the outdoor unit Service Facts.
1. Determine the most practical way to run the lines.
2. Consider types of bends to be made and space limitations.
NOTE:
Large diameter tubing will be very difficult to rebend once it
has been shaped.
3,
4.
5.
6.
7.
8.
Determine the best starting point for routing the refriger-
ant tubing - -INSIDE OR OUTSIDE THE STRUCTURE.
Provide a pull-thru hole of sufficient size to allow both
liquid and gas lines.
Be sure the tubing is of sufficient length.
Uncoil the tubing --- do not kink or dent.
Route the tubing making all required bends and properly
secure the tubing before making connections.
To prevent a noise within the building structure due to
vibration transmission from the refrigerant lines, the
following precautions should be taken:
a. When the refrigerant lines have to be fastened to floor
joists or other framing in a structure, use isolation
type hangers.
LiQUiD LiNE SERVICE VALVE
ROLLED EDGE TO
CAP_ @/CAPTIVATE STEM
sEO.ffS ,S'DEOF--- -- .EX.EADgEM
SERVICE _ _ /
PORT -- /
LIQUID LINE
CONNECTION
© 2002 American Standard Inc. All Rights Reserved 18-BC51 D2-3
|nsta||er's Guide
@GAS LiNE BALL SERVICE VALVE
CAP ---__ ,I-J, 1/4 TURN ONLY
COUNTERCLOCKWISE
FOR FULL OPEN
I _ POSITION
VALVEBTEM
UNITSIDE
OFVALVE
PRESSURETAPPORT /
GAS LINE CONNECTION
o,.
CAP _ (_
BODY
COOL
L_ZI i _17_q
CORE
b. Isolation hangers should also be used -when refriger-
ant lines are run in stud spaces or enclosed ceilings.
c. Where the refrigerant lines run through a wall or sill,
they should be insulated and isolated.
d. Isolate the lines from all ductwork.
E. SERVICE VALVE OPERATION
BRASS LIQUID AND GAS LINE SERVICE VALVES
The Brass Liquid and Gas Line Service Valves are factory
shipped in the seated position to hold factory charge. The
pressure tap service port (when depressed) opens only to the
field brazing side of the valve when the valve is in the seated
position. The liquid line valve is not a back seating valve (see
WARNING below).
Extreme caution should be exercised when opening the
Liquid and Gas Line Service Valves. Turn valve stem
counterclockwise only until the stem contacts the roiled
edge. (See Figures 4 and 6) No torque is required.
BRASS GAS LINE BALL SERVICE VALVE
The Brass Gas Line Service Valve is shipped in the closed
position to hold the factory refrigerant charge. The pressure
tap service port (when depressed) opens only to the field
brazing side when the valve is in the closed position.
The Gas Line Service Valve is full open with a 1/4 turn. See
Figure 5.
BRAZING REFRIGERANT LINES
1. Remove lower access cover to access service valves.
2. Before brazing, remove plugs from external copper stub
tubes. Clean internal and external surfaces of stub tubes
prior to brazing.
3. Cut and fit tubing, minimizing the use of sharp 90 ° bends.
4. Insulate the entire gas line and its fittings.
5. Do NOT allow uninsulated liquid line to come in direct
contact with bare gas line.
®GAS LiNE SERVICE VALVE
ROLLED EDGE TO
CAP_ @/CAPTIVATE STEM
UNIT SIDE OF
SERVICE VALVE
HEXHEADED
VALVE SYSTEM
SERVICE-_q
PORT /
GASLINE
CONNECTION
6. Precautions should be taken to avoid heat damage
to the pressure tap valve core during brazing. It is
recommended that the pressure tap port valve
core be removed and a wet rag wrapped around
the valve body.
NOTE:
Use care to make sure that no moisture enters pressure tap
port, while wet rag is being used.
NOTE:
Precautions should be taken to avoid heat damage to
basepan during brazing. It is recommended to keep the
flame directly off of the basepan.
7. Use a Dry Nitrogen Purge and Brazing Alloy without
flux when brazing the field line to the copper thctory
connection. Flow dry nitrogen into either valve pressure
tap port, thru the tubing and out the other port while
brazing.
8. Braze using accepted good brazing techniques.
LEAK CHECK
IMPORTANT:
Replace pressure tap port valve core before attaching hoses for
evacuation.
After the brazing operation of refrigerant lines to both the
outdoor and indoor unit is completed, the field brazed
connections must be checked for leaks. Pressurize through
the service valve ports, the indoor unit and field refrigerant
lines with dry nitrogen to 350-400 psi. Use soap bubbles or
other leak-checking methods to see that all field joints are
leak-free! If not, release pressure; then repair!
SYSTEM EVACUATION
NOTE:
Since the outdoor unit has a refrigerant charge, the gas and
liquid line valves must remain closed.
1. Upon completion of leak check, evacuate the refrigerant
lines and indoor coil before opening the gas and liquid
line valves.
2. Attach appropriate hoses from manifold gauge to gas
and liquid line pressure taps.
NOTE:
Unnecessary switching of hoses can be avoided and corn=
plete evacuation of all lines leading to sealed system can be
accomplished with manifold center hose and connecting
branch hose to a cylinder of HCFC-22 and vacuum pump.
18-BC51 D2-3 3
|nstaI|er's Guide
3. Attach center hose of manifold gauges to vacuum pump.
4. Evacuate until the micron gauge reads no higher than
350 microns.
5. Close offvalve to vacuum pump and observe the micron
gauge. If gauge pressure rises above 500 microns in one
(1) minute, then evacuation is incomplete or system has
a leak.
6. If vacuum gauge does not rise above 500 microns in one
(1) minute, the evacuation should be complete.
7. With vacuum pump and micron gauge blanked off; open
valve on HCFC-22 cylinder and charge refrigerant lines
and indoor coil with vapor to tank pressure of HCFC-22
supply.
NOTE:
DO NOT VENT REFRIGERANT INTO THE ATMOSPHERE.
5. Provide flexible electrical conduit whenever vibration
transmission may create a noise problem within the
structure.
6. The use of color coded low voltage wire is recommended
to simplify connections between the outdoor unit, the
thermostat and the indoor unit.
Table 1--- NEC Class II Control Wiring
24 VOLTS
WIRE SIZE MAX. WIRE LENGTH
18 AWG 150 FT
16 AWG 225 FT.
14 AWG 300 FT.
8. Close valve on HCFC-22 supply cylinder. Close valves on
manifold gauge set and remove refrigerant charging
hoses from liquid and gas pressure tap ports.
NOTE:
A 3/16" Allen wrench is required to open liquid line service
valve. A 1/4" Open End or Adjustable wrench is required to
open gas line valve. A 3/4" Open End wrench is required to
take off the valve stem cap.
9. The liquid line shut-offvalve ean now be opened.
Remove shut-offvalve cap. Fully insert hex wrench into
the stem and backout counterclockwise until valve stem
just touches rolled edge (approximately five [5] turns)
observing WARNING statement on page 3. See Figure 4.
10. Replace liquid service pressure tap port cap and valve
stem eap. These caps MUST BE REPLACED to
prevent leaks. Replace valve stem and pressure tap cap
finger tight, then tighten an additional 1/6 turn.
11. The gas valve can now be opened. For a ball type gas
valve, open the gas valve by removing the shut-offvalve
cap and turning the valve stem 1/4 turn counterclock-
wise, using 1/4" Open End or Adjustable wrench. See
Figure 5. For brass gas line service valve opening, follow
9 and 10 above. See Figure 6.
12. The gas valve is now open for refrigerant flow. Replace
valve stein cap to prevent leaks. Again, these eaps
MUST BE REPLACED to prevent leaks. Replace valve
stem and pressure tap cap finger tight, then tighten an
additional 1/6 turn. See Figure 4.
If refrigerant lines are longer than 15 feet and/or a difi_rent
size than recommended, it will be necessary to adjust system
refrigerant charge upon completion of installation. See unit
Service Facts.
F. ELECTRICAL CONNECTIONS
When installing or servicing this equipment, ALWAYS
exercise basic safety precautions to avoid the possibility
of electric shock.
1. Power -wiring and grounding of equipment must comply
with local codes.
2. Power supply must agree with equipment nameplate.
3. Install a separate disconnect switch at the outdoor unit.
4. Ground the outdoor unit per local code requirements.
7.
8.
Table 1 defines maximum total length of low voltage
wiring from outdoor unit, to indoor unit, and to
thermostat.
Mount the indoor thermostat in accordance with instruc-
tion included -with the thermostat. Wire per appropriate
hook-up diagram (included in these instructions).
G. DEFROST CONTROL
The demand defrost control measures heat pump outdoor
ambient temperature with a sensor located outside the
outdoor coil. A second sensor located on the outdoor coil is
used to measure the coil temperature. The diffhrence be-
tween the ambient and the colder coil temperature is the
diffhrence or delta-T measurement. This delta-T measure-
ment is representative of the operating state and relative
capacity of the heat pump system. By measuring the change
in delta-T, we can determine the need for defrost. The coil
sensor also serves to sense outdoor coil temperature for
termination of the defrost cycle.
FAULT iDENTiFICATiON
A fault condition is indicated by the flashing light on the
defrost control inside the heat pump control box.
In normal operation, the defrost control light will flash once
each second. If the light is flashing more than once per
second or not at all, refer to the service manual for that unit.
PiN iDENTiFiCATiON (See Figure 7.)
1. TEST_COMMON (Shorting any of the other pins to this
pin causes the function of the other pin to be executed.
Leaving this pin open results in the normal mode of
operation.)
2. TST = Test (Shorting TEST_COMMON to this pin
speeds up all defrost board timings.)
©PiN iDENTiFiCATiON
Z
0
o
oI
LL
° m
LL
\
p-
4 18-BC51 D2-3
|nsta||er's Guide
3. FRC_DFT = Forced Defrost (Short TEST_COMMON to
this pin for two (2) seconds to initiate a forced defrost.
Remove the short after defrost initiates.)
DEFROST CONTROL CHECKOUT
Normal operation requires:
a. LED on board flashing 1 time/second.
b. 24V AC between R & B
c. 24V AC between Y & B with unit operating
d. Defrost initiation when FRC_DFT pin is shorted to
TEST_COMMON pin.
If a defrost control problem is suspected, refer to the service
information in control box.
Do NOT connect 24 VAC to T1 (ODS=A) terminal. ODS=A
thermistor WILL BE BLOWN.
I. OPERATIONAL AND CHECKOUT
PROCEDURES
Final phases of this installation are the unit Operational and
Checkout Procedures which are found in this instruction on
page 8. To obtain proper performance, all units must be
operated and charge adjustments made in accordance with
procedures found in the Service Facts.
J. ELECTRIC HEATERS
Electric heaters, if used, are to be installed in the air han-
dling device according to the instructions accompanying the
air handler and the heaters.
K. START CONTROL
Some models have quick start components which are fhctory
installed. For models that do not have factory installed start
components, provisions are made for a field installed start kit
accessory. When adding an accessory, follow the instructions
provided with the kit.
H. COMPRESSOR START UP
After all electrical wiring is complete, SET THE THERMO-
STAT SYSTEM SWITCH IN THE OFF POSITION SO
COMPRESSOR WILL NOT RUN, and apply power by closing
the system main disconnect switch. This will activate the
compressor sump heat (where used). Do not change the
Thermostat System Switch until power has been applied for
one (1) hour. Following this procedure will prevent potential
compressor overload trip at the initial start-up.
L. OUTDOOR THERMOSTAT
An outdoor thermostat TAYSTAT250B may be field installed.
For data, see wiring diagram attached to unit and instruction
sheet packaged with outdoor thermostat.
M. SEACOAST SALT SHIELD
Units installed -within one mile of salt water including
seacoasts and inland waterways, require the addition of
BAYSEAC001 (Seacoast Kit) at the time of installation.
IMPORTANT:
See Limited Warranty information in Use and Care Manual.
TYPICAL FIELD HOOK=UP DIAGRAMS
T'3T/_T
0 _
i ,
G;
i i }
i iB; ;
i i
)iR H,',,I,,DER
_---'i_
(
:ii\
I[...,:_
ii'
,,
L....[_
[ i
> l i, r riD ::<W B5290,>03
Notes:
HF,',,T PU:_4P
@ ,.
L... i
R-n 0
F!K X2 )
_----_,;
: _"--'_!R( T )
1. Be sure power supply agrees with equipment nameplate.
2. Power wiring and grounding of equipment must comply with local codes.
3. Low voltage wiring to be No. 18 AWG minimum conductor.
4. ODT-B must be set lower than ODT-A.
,5. If outdoor thermostats (ODT) are not used, connect W1 to W2 and W3.
6. N/A to programmable thermostat.
'S ;, iAR A,i; SP II)
,::, R HA!',[) ER II[/; i PU_,'I
._,."... y
-- _- --
:iK(X1_)
.... .__c.P._9.'_i ._u4o{_.
-_ B
D- [/01{ 6 D
PR i,i F;;' FROM , i :1;'9 )4PO{Z
LEGEND
..... FACTORY WIRING
FIELD WIRING
18-BC51 D2-3 5
Installer's Guide
SERViCr PANE[ .......... _
IIICIRiCAI ANI) iRIFIRiG_RA_i
COMPONENT C[LARA_C_S
PER PREVAilinG CO_LS
iOP DiSCiiARGE AREA SiiOULD BE
UNRESTRICTED FOR AT LEAST 1524 (5 FEET}
A_OVE UN[_ d_lJ ¸ S_IOU[b BE PEACED SO ROOi
i!_O[[ ¸ WATE[i _O[S NO] _O_R _I_E¢iL¥ ON UNi]
£_i) SHOWi) _i_ A/ JI_ASI¸ 30_ (i_ ¸¸} EROM WA[i ANJ)
ALL SORROUNDiNG SHRUBBERY O_ IWO SinES¸
OTFIER TWO Si_[S U_R_STRiCT[_
FA_EL _ L
25 7 :J
2_ 2 (bS) i_ i011£ .............. .
I O_i ?9 I &( ( . ---
28 f, ', 1_8} DIA K 0 _l H........
22 2 7/8} DIA OlE i_ C,91TR,PL j
BOX tX) I 'C4 [:OH EL E( R ( AL j
/()W_iSIJP[ ' _ .....
i
(;'U [J _[ S R_iC[ ?/_,'E, -''1''_= ,
@ [: HA [ BE{;} HT I I_
COr_/ECl }01i /i I /,I SA[ F_L
LARE PRESSURE I_P il IGS j ,i il
G_
MODELS BASE FIG. A
2TWR1018A 2 2 651 (25-5/8)
2TWR1024A 2 2 651 (25-5/8)
2TWR1030A 2 2 730 (28-3/4)
2TWR1036A 2 2 730 (28-3/4)
2TWR1042A 3 2 832 (32-3/4)
2TWR1048A 3 2 832 (32-3/4
2TWR1060A 4 1 841 (33-1/8)
2TWR2018A 2 2 651 (25-5/8)
2TWR2024A 2 2 730 (28-3/4)
2TWR2030B 2 2 832 (32-3/4)
2TWR2036A 3 1 832 (32-3/4)
2TWR2042A 3 1 832 (32-3/4)
2TWR2048A 3 1 933 (36-3/4)
2TWR2060A 4 1 1045 (41-1/8)
j;,
FIG. 1
\ KO [OH AiTER_A[E
,, C i IleAl OJ Iq',,
\ GAS i iNE I/4 iWiN SAil SIRVICI VAJVL 'l)'
ID FE_£LE BRAZED CO_N[CTiO_ _IT_ [/4 ¸¸ SA[
FiARE PR[SSbR_ TAP FiTTi_6
B
724 (28-1/2)
724 (28-1/2)
724 (28-1/2)
724 (28-1/2)
829 (32-5/8)
829 (32-5/8)
946 (37-1/4)
724 (28-1/2)
724 (28-1/2)
724 (28-1/2)
829 (32-5/8)
829 (32-5/8)
829 (32-5/8)
946 (37-1/4)
C
651 (25-5/8)
651 (25-5/8)
651 (25-5/8)
651 (25-5/8)
756 (29-3/4)
756 (29-3/4)
870 (34-1/4)
651 (25-5/8)
651 (25-5/8)
651 (25-5/8)
756 (29-3/4)
756 (29-3/4)
756 (29-3/4)
870 (34-1/4)
A
I I(/;I) t [! S _,,' '3
V , ' I t4A
BRAZED CO,i!'E,30l
WI I _,1 SAE FLARE
PRESSUR Ts,P f TT_G
GAS Li:/ SIVCE VALVE, x
I D FEI_'ALF BRAZED
¢ON_[¢[I()_ WlTli i/4 '¸ SA[ FLARE
i_R[S$[iR_ lAP i¸ il_ iN6
D E F G H J K
5/8 1/4 127 (5) 57 (2-1/4) 180 (7-1/8) 44 (1-3/4) 457 (18)
3/4 5/16 127 (5) 57 (2-1/4) 180 (7-1/8) 44 (1-3/4) 457 (18)
3/4 5/16 137 (5-3/8) 65 (2-5/8) 210 (8-1/4) 57 (2-1/4) 457 (18)
7/8 3/8 137 (5-3/8) 65 (2-5/8) 210 (8-1/4) 57 (2-1/4) 457 (18)
7/8 3/8 137 (5-3/8) 86 (3-3/8) 210 (8-1/4) 79 (3-1/8) 508 (20)
1-1/8 3/8 137 (5-3/8) 86 (3-3/8) 210 (8-1/4) 79 (3-1/8) 508 (20)
1-1/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20)
5/8 1/4 127 (5) 57 (2-1/4) 180 (7-1/8) 44 (1-3/4) 457 (18)
3/4 5/16 137 (5-3/8) 65 (2-5/8) 210 (8-1/4) 57 (2-1/4) 457 (18)
3/4 5/16 137 (5-3/8) 65 (2-5/8) 210 (8-1/4) 57 (2-1/4) 457 (18)
7/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)
7/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)
1-1/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)
1-1/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20)
From Dwg. 21D152898 Rev. 9
6 18-BC51 D2-3
|nstal|er's Guide
MOUNTING HOLE LOCATION
Note: All dimensions are in IVllVl(Inches).
BASE 2
BASE 3
NOTE: For model base size,
see table on page 6.
........................................................$99 (255 n_ ......................................................
4
_?f (2864)
BASE 4 From Dwg. 21 D152637 Rev. 1
18-BC51 D2-3 7
|nsta||er's Guide
CHECKOUT PROCEDURE
After installation has been completed, it is recommended that the entire system be checked against the following list:
1. Refrigerant Line, Leak checked .................................. [
2. Suction Lines and Fittings properly insulated ........... [
3. Have all Refrigerant Lines been secured and
isolated properly? ........................................................ [
4. Have passages through masonry been sealed?
If mortar is used, prevent mortar from coining
into direct contact with copper tubing ........................ [
5. Verify tightness of all electrical connects ................... [
6. Observe outdoor fan during on cycle for clearance
and smooth operation ................................................. [
]
]
]
]
8. Supply registers and return grilles open and
unobstructed ............................................................... [ ]
9. Return air filter installed ............................................ [ ]
10. Thermostat thermometer is accurate. Check
against a reliable thermometer. Adjust per
instructions with thermostat ...................................... [ ]
11. Is correct speed tap being used?
(Indoor blower motor) ................................................. [ ]
12. Operate complete system in each mode to
insure safe operation ................................................... [ ]
7. Indoor coil drain line drains freely. Pour water
into drain pan .............................................................. [
TROUBLESHOOTING CHART m WHAT TO CHECK
SYSTEMFAULTS
REFRIGERANTCIRCUIT
HeadPressure Too High
HeadPressure Too Low
SuctionPressureTooHigh
SuctionPressureTooLow
LiquidBefrig Eloodback(TXV)
IELCoil Frostiag
ELECTRICAL
Compressor& OB Fan
Won't Start
CompressorWill Not Start
But OD EalqRuns
OD FanWon't Start
CompressorHums ButWon't Start
CompressorCycleson I01.
IELBlower Won't Start
DEFROST
UnitWon't Initiate Defrost
DefrostTerminatesonTime
Unit IcingUp
C - Cooling H - Heating
s s
s s
s s
ss ii
$p
$p
s P
s P
s p
s p
P Ss PP
P P
P
P
P - PrimaryCauses S - SecondaryCauses "k - 3 PhaseOnly
C
T J.N£
Trane
A business of
American Standard Companies
www.trane.com
Literature Order Number 2TWR2-iN-1B RI. 2/03
File Number SV-UN-S/SP-2TWR2-1N-1B
Supersedes 2TWR2-1N-1A
Stocking Location PI Louisville & Webb/Mason-Houston
Trane has a policy of continuous product and product data improvement and it reserves the right to change
design and specifications without notice.