TRICKLESTAR TS1909 ZigBee TAV-Link Multi-Sensor User Manual DS TS1811 5 Jan 2016
TrickleStar Limited ZigBee TAV-Link Multi-Sensor DS TS1811 5 Jan 2016
User Manual
TIER 2 ZIGBEE MULTI-SENSOR ADVANCED POWERSTRIP+ TS1811 7 OUTLET TIER 2 ADVANCED POWERSTRIP+ ZIGBEE® MULTI-SENSOR Premium quality, fireproof surge protection that reduces standby and active power waste from electronics OVERVIEW KEY FEATURES The Tier 2 ZigBee® Multi-Sensor Advanced PowerStrip+ (APS+) provides premium quality surge protection and reduces the amount of standby and active power wasted by electronics. The APS+ is designed for use with set-top box systems. The APS+ includes a low voltage RJ11 port which supports the connection of a Zigbee®-enabled multi-sensor that senses radio frequency (RF), infrared (IR), and motion. The APS+ includes advanced power measurement and patented auto-threshold detection. This allows the APS to accurately support all types of televisions from old to new high efficiency types. It provides automation to reduce wasteful standby and active power, and it is suitable for TV/home theater applications. In addition to standard power switching, the APS+ also supports “soft switching” via high-level CEC commands from the multi-sensor to an HDMI port on the TV; this feature is known as TAV-Link and will result in placement of connected HDMI devices into a power-saving state by high-level commands. 7 Outlets 2 Always On Outlets (1 outlet transformer spaced) 5 Switched Outlets (1 outlet transformer spaced) 15A resettable circuit breaker Auto threshold detection Intelligently adjusts to new equipment True RMS power sensing 72,000 Amps/1080 Joules Ceramic surge protection Low-voltage, optically-isolated RJ11 input LED status indication (ground, surge status, switched) <40dB noice filtering Angled space saver plug ZigBee enabled multi-sensor CEC TAV-Link function FIREPROOF SURGE PROTECTION Traditional surge suppression products use standard MOV (metal oxide varistor) components. TrickleStar Tier 2 APS+ incorporates advanced surge protection technology. The MOVs are encased in ceramic and are capable of suppressing more energy and dissipating heat faster than traditional MOVs. More importantly, the ceramic casing is fireproof and therefore is capable of preventing fire during surge conditions. PRODUCT WARRANTY 10-year product warranty $20,000 connected equipment warranty TM The best way to save energy is to stop wasting it. www.tricklestar.com TIER 2 ZIGBEE® MULTI-SENSOR ADVANCED POWERSTRIP+ PAIRING DirecTV® or Comcast® REMOTE CONTROL ZIGBEE® MULTI-SENSOR STEP 1 Detects ZigBee RF4CE* RF, IR remote control signals and motion. Includes a configurable countdown timer that will switch off the TV and peripherals if no RF, IR or motion is detected. Quickly press the pinhole pairing button located on the back of the multi-sensor to trigger the pairing process. Status LED flashes when RF, IR or motion is detected. A blue LED will flash for a period of 15 seconds - indicating the multi-sensor is in pairing mode. Patented sensing hardware and algorithm looks for RF and IR commands first. It then looks for motion after a period where no RF or IR commands are detected. STEP 2 Supports high level CEC* commands via TAV-Link cable to the TV and to the peripherals for soft switch off. Place the RF4CE DirecTV or Comcast remote near the sensor (within two inches) and press the 0 key on the remote until the red LED illuminates. Repeat with other RF4CE remote controls (up to four). TAV-Link functionality allows “smart” TVs to store their data and settings safely before powering down. TAV-Link also allows gaming consoles to enter an energy-saving mode earlier and without any corruption of data. The multi-sensor will exit pairing mode after 15 seconds if no RF button presses are detected. Supports RF4CE pairing with DirecTV® and Comcast® remote controls (can pair up to 4 remotes). Includes a soft chirp, piezo buzzer to warn of a pending shutdown 10 minutes prior to shutdown. Manual on/off button. *CEC (Consumer Electronics Control) is the control protocol found in HDMI. APPLICATION DIAGRAM Programming the Countdown Timer *RF4CE (Radio Frequency for Consumer Electronics) is a radio frequency protocol for audio and video device remote controls. It provides two-way, high-speed communications which allow remote signals to transmit through cabinets, obstacles, walls and floors. ZIGBEE RF, IR, & MOTION MULTI-SENSOR TAV-LINK (for CEC function) RF + IR TV REMOTE To configure the countdown timer, press and hold the button for 10 seconds until the red LED illuminates. Then press: • Once for 30 minutes • Twice for 60 minutes • Three times for 120 minutes consoles without hard disk drives (HDD) should be * Game plugged into a switched outlet. Those with hard disk drives can be plugged into an always-on outlet and controlled via TAV-Link. LED will flash once for 30 minutes, twice for 60 minutes (default setting) and three times for 120 minutes. TM The best way to save energy is to stop wasting it. www.tricklestar.com TIER 2 ZIGBEE® MULTI-SENSOR ADVANCED POWERSTRIP+ ELECTRICAL SPECIFICATIONS PIR & IR DETECTION PATTERN TIER 2 APS+ SENSOR OPTICAL VIEW PATTERN FOR INDOOR USE Operating Voltage Output Current Maximum Total Load Noise Filtering Power Consumption 16.40 ft. 13.12 ft. 9.84 ft. 6.56 ft. 3.28 ft. 19.69 ft. 120 VAC +/- 10% 60Hz 15 Amps RMS 1800W <40dB <1W at 120VAC, 60Hz (in all modes of operation) RJ11 APS+ Cord Length Outlets (7 Outlets) 3.3V & Optically Isolated 4 ft. (1.2 meters) 2 Always ON 3.28 ft. 6.56 ft. 9.84 ft. 13.12 ft. 16.40 ft. 19.69 ft. 16.40 ft. 16.40 ft. 13.12 ft. 13.12 ft. 9.84 ft. 9.84 ft. 6.56 ft. 6.56 ft. 3.28 ft. 3.28 ft. (1 outlet transformer spaced) 3.28 ft. 3.28 ft. 6.56 ft. 6.56 ft. 9.84 ft. 9.84 ft. 13.12 ft. 13.12 ft. 16.40 ft. 16.40 ft. 19.69 ft. 19.69 ft. 5 Switched Outlets (1 outlet transformer spaced) LED Status Indication Surge Protection Input Current Ground, Surge, Switched 72,000 Amps / 1080 Joules for all outlets (Ceramic Surge Protection) 15A Resettable Circuit Breaker RF Detection Range: 16.4 ft. Degree: 360° MULTI SENSOR FOR INDOOR USE Voltage IR Detection Angle/Range PIR Detection Angle/Range RF Detection Range Cord Length Sensor Detection 3.3V 60°/Up to 16.4 ft. (5 meters) 90°/Up to 16.4 ft. (5 meters) 360°/Up 16.4 ft. (5 meters) 8 ft. Infrared, Passive Infrared and ZigBee RF4CE PHYSICAL SPECIFICATIONS Operating Temperature Storage Temperature Humidity IP Rating IR Detection Range: 16.4 ft. Degree: 60° PIR Detection Range: 16.4 ft. Degree: 90° APPROVALS Conformity to product standards for safety and EMC UL (US & Canada), 2002/95/EG (RoHs), 2002/96/EC (WEEE), 1999/5/EC (RTTE), FCC Approved, ZigBee Certified ORDER INFORMATION TS1811 7 Outlet APS+, 1080 Joules, 4 ft. Cord, Auto Threshold, Zigbee Multi-Sensor, TAV-Link 32° to 113° F 14° to 140° F 5 to 90% N/C IP20 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. Copyright © TrickleStar. All rights reserved. TrickleStar® is a registered trademarks of TrickleStar Ltd. All other trademarks are the property of their respective owners. The information in this document is subject to change without notice. TrickleStar assumes no responsibility for any errors that may appear in this document. REV 5 Jan 2016 TM The best way to save energy is to stop wasting it. www.tricklestar.com ® Quick Start Guide & Instruction Manual ® PRODUCT INFORMATION Copyright© TrickleStar LLC 2016. All rights reserved. TrickleStar® is a registered trademark of TrickleStar Ltd. All other trademarks are the property of their respective owners. The information in this document is subject to change without notice.TrickleStar assumes no responsibility for any errors that may appear in this document. For technical support go to www.tricklestar.com or call 1-888-700-1098 TS1811 7 Outlet Advanced PowerStrip+, 1080 Joules, 4 ft. Cord, Auto Threshold, Zigbee Multi-Sensor, TAV-Link www.tricklestar.com Product Warranty Installation The Lifetime of the Product is 10 years (hereafter referred to as Product Lifetime). TrickleStar warrants to the original purchaser that for the Product Lifetime, it shall be free of defects in design, assembly, material, or workmanship, and will repair or replace, at its option, any defective product free of charge. CONNECTED DEVICE WARRANTY TrickleStar will repair or replace, at its option, any devices which are damaged by a transient voltage surge/spike or lightning strike, (an “Occurrence”), while properly connected through the Product to a properly wired AC power line with protective grounding. If applicable; the telephone line, and/or network line must be properly connected and installed, and the antenna cable line must also be properly connected and installed, as determined by TrickleStar at its sole discretion. Programming the ThisCountdown Connected DeviceTimer Warranty is a Limited Warranty, subject to the limitations and TAV-LINK exclusions set forth herein. TrickleStar will repair or replace the damaged connected (for CEC function) devices, at TrickleStar’s option, an amount equal to the fair market value of the damaged devices or the original purchase price of the devices, whichever is less, up to the maximum of: $20,000 The fair market value of the devices shall be the current value of the devices specified in the most recent edition of the Orion Blue Book by Orion Research Corporation, Roger Rohrs Publisher. IR AND RF TrickleStar reserves the right to review the damaged Product, the damaged devices, and TV REMOTE the site where the damage occurred. All costs of shipping the Product and the damaged devices to TrickleStar for inspection shall be borne solely by the purchaser. TrickleStar reserves the right to negotiate the cost of repairs. If TrickleStar determines, in its sole discretion, that it is impractical to ship the damaged devices to TrickleStar, TrickleStar may designate, in its sole discretion, atimer, repairpress facility to inspect and estimate the cost to repair To configure the countdown such devices. Thebutton cost, iffor any, shippinguntil the devices to and from such repair facility and and hold the 10ofseconds of such estimate shall be borne solely by the purchaser. the red LED illuminates. Then press: • Once for 30 minutes Damaged must remain available for inspection until the claim is finalized. • Twicedevices for 60 minutes Whenever claims are settled, TrickleStar reserves the right to be subrogated under any • Three times for 120 minutes existing insurance policies the claimant may have. All above warranties are null and void if: LED will flash once for 30 minutes, twice • The Product in use during the occurrence is not provided to TrickleStar for inspection for 60 TrickleStar minutes (default setting) upon ’s request at theand solethree expense of the purchaser. for 120 minutes.that the Product has not been installed in accordance with the • times TrickleStar determines Installation Requirements, altered in any way or tampered with. • TrickleStar determines that the damage did not result from the occurrence or that no occurrence in fact took place, the repair or replacement of the damaged devices is covered under a manufacturer’s warranty. • TrickleStar determines that the connected devices were not used under normal operating conditions or in accordance with any labels or instructions. • The Product is not plugged directly into a receptacle. • The Product is “daisy-chained” together in serial fashion with other power boards, UPS’, other surge protectors or extension cords. • A three-to two-prong adapter is used. • The Product is not used indoors. www.tricklestar.com www.tricklestar.com 7 Advanced Outlet PowerStrip+ This Product is not for use with aquariums and all other water-related products. Use only indoors and in dry locations. The Connected Device Warranty only protects against damage to properly connected devices where TrickleStar has determined, in its sole discretion, that the damage resulted from an occurrence, and does not protect against acts of God (other than lightning) such as flood, earthquake, war, vandalism, theft, normal-use wear and tear, erosion, depletion, obsolescence, abuse, damage due to low voltage disturbances (i.e. brownouts or sags), non-authorized program, or system devices modification or alteration. This warranty contains the sole warranty of TrickleStar, there are no other warranties, expressed or, except as required by law, implied, including the implied warranty RF or condition of quality, merchantability or fitness for a particular purpose, and + IR + MOTION such implied warranties, if any, are limited in duration to the term of this warranty. Some + DIRECTV states doMULTI-SENSOR not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. In no event shall TrickleStar be liable for incidental, special, direct, indirect, consequential or multiple damages such as, but not limited to, lost business or profits arising out of the sale or use of any Product, even if advised of the possibility of such damages. This warranty gives you specific legal rights, and you may also have other rights, which may vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty is valid only for the original purchaser of the product. All damage claims against the product must be made within 15 days from the date of the occurrence and must be accompanied by a receipt for the damaged devices or the warranty is void. Warranty is valid in USA and Canada. MAKING A WARRANTY CLAIM Go to: www.tricklestar.com warranty@tricklestar.com and print our claim form and email it to Provide the following information: • Product part number • A list of the devices that were connected to the Product at the time of the occurrence • A list of the devices that were damaged during the occurrence and the extent of the Game consoles without hard drives are recommended to be damage into a switched outlet. • The dateplugged of the occurrence Those with hard can be plugged into an always on outlet • Where you purchased thedrives Product andpurchased controlled TAV-LINK • When you thevia Product • A copy of original receipt A customer service representative will then instruct you on how to forward your devices, receipt and Product in use during the “occurrence” and how to proceed with your claim. COPYRIGHT & DISCLAIMER © Copyright TrickleStar Ltd. All rights reserved.TrickleStar® is a registered trademark of TrickleStar. Any typographical, clerical or other error or omission in this document or other documents or information issued by TrickleStar shall be subject to correction without any liability on the part of TrickleStar without notice. REV 5 Jan 2016 Advanced Advanced Powerstrip+ Powerstrip+ Product Warranty Installation The lifetime of the product (hereafter referred to as “Product Lifetime”), is 10 years. TrickleStar warrants to the original purchaser that for the Product Lifetime, it shall be free of defects in design, assembly, material, or workmanship, and will repair or replace, at its option, any defective product free of charge. CONNECTED DEVICE WARRANTY TrickleStar will repair or replace, at its option, any devices which are damaged by a transient voltage surge/spike or lightning strike, (an “Occurrence”), while properly connected through the Product to a properly wired AC power line with protective grounding. If applicable, the telephone line, and/or network line must be properly connected and installed, and the antenna cable line must also be properly connected and installed, as determined by TrickleStar at its sole discretion. Programming The This Countdown Connected DeviceTimer Warranty is a limited warranty, subject to the limitations and TAV-LINK exclusions set forth herein. TrickleStar will repair or replace the damaged connected (for CEC function) devices, at TrickleStar’s option, an amount equal to the fair market value of the damaged devices or the original purchase price of the devices, whichever is less, up to the maximum of $20,000. The fair market value of the devices shall be the current value of the devices specified in the most recent edition of the Orion Blue Book by Orion Research Corporation, Roger Rohrs Publisher. IR AND RF TrickleStar reserves the right to review the damaged Product, the damaged devices, and TV REMOTE the site where the damage occurred. All costs of shipping the Product and the damaged devices to TrickleStar for inspection shall be borne solely by the purchaser. TrickleStar reserves the right to negotiate the cost of repairs. If TrickleStar determines, in its sole discretion, that it is impractical to ship the damaged devices to TrickleStar, TrickleStar may designate, its sole a repairOn/Off facility to inspect and estimate the cost to repair Press in and holddiscretion, the operation such devices. cost, if any, of shipping button for The 10 seconds. Then press: the devices to and from such repair facility and of such estimate be borne solely by the purchaser. - Once for 30shall minutes - Twice for 60 minutes Damaged remain available for inspection until the claim is finalized. - Thricedevices for 120 must minutes Whenever claims are settled, TrickleStar reserves the right to be subrogated under any existing insurance policies the claimant may have. All above warranties are null and void LED will flash once for 30 minutes, twice if: for Product 60 minutes (default andis not provided to TrickleStar for inspection • The in use during thesetting) occurrence thrice for 120 minutes. upon TrickleStar ’s request at the sole expense of the purchaser. • TrickleStar determines that the Product has not been installed in accordance with the Installation Requirements, altered in any way or tampered with. • TrickleStar determines that the damage did not result from the occurrence or that no occurrence in fact took place, the repair or replacement of the damaged devices is covered under a manufacturer’s warranty. • TrickleStar determines that the connected devices were not used under normal operating conditions or in accordance with any labels or instructions. • The Product is not plugged directly into a receptacle. • The Product is “daisy-chained” together in serial fashion with other power boards, Uninterruptible Power Supplys, other surge protectors or extension cords. • A three-to two-prong adapter is used. • The Product is not used indoors. 7 Advanced Outlet PowerStrip+ This Product is not for use with aquariums and all other water-related products. Use only indoors and in dry locations. The Connected Device Warranty only protects against damage to properly connected devices where TrickleStar has determined, in its sole discretion, that the damage resulted from an occurrence, and does not protect against acts of God (other than lightning) such as flood, earthquake, war, vandalism, theft, normal-use wear and tear, erosion, depletion, obsolescence, abuse, damage due to low voltage disturbances (i.e. brownouts or sags), non-authorized program, or system devices modification or alteration. This warranty contains the sole warranty of TrickleStar, there are no other warranties, expressed or, except as required by law, implied, including the implied warranty or condition quality, merchantability or fitness for a particular purpose, and ZIGBEE RF,ofIR, such implied warranties, if any, are limited in duration to the term of this warranty. Some MOTION states do MULTI-SENSOR not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. In no event shall TrickleStar be liable for incidental, special, direct, indirect, consequential or multiple damages such as, but not limited to, lost business or profits arising out of the sale or use of any Product, even if advised of the possibility of such damages. This warranty gives you specific legal rights, and you may also have other rights, which may vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty is valid only for the original purchaser of the product. All damage claims against the product must be made within 15 days from the date of the occurrence and must be accompanied by a receipt for the damaged devices or the warranty is void. Warranty is valid in USA and Canada. MAKING A WARRANTY CLAIM Go to: www.tricklestar.com warranty@tricklestar.com and print our claim form and email it to Provide the following information: • Product part number. • A list of the devices that were connected to the Product at the time of the occurrence. • A list of the devices that were damaged during the occurrence and the extent of the Game consoles without hard disk drives (HDD) should be damage. into a switched outlet. Those with hard disk drives can • The dateplugged of the occurrence. be purchased plugged into always-on outlet and controlled via • Where you the an Product. TAV-Link. • When you purchased the Product. • A copy of original receipt. A Customer Service Representative will then instruct you on how to forward your devices, receipt and Product in use during the “occurrence” and how to proceed with your claim. COPYRIGHT & DISCLAIMER © Copyright TrickleStar Ltd. All rights reserved.TrickleStar® is a registered trademark of TrickleStar. Any typographical, clerical or other error or omission in this document or other documents or information issued by TrickleStar shall be subject to correction without any liability on the part of TrickleStar without notice. REV 17/12/15 surge ground switched www.tricklestar.com Advanced Powerstrip+ Troubleshooting No power at switched outlets subwoofer How does the APS+ save energy? The APS+ saves energy through: 1) Master control • All switched outlets are automatically switched off 1 minute after the TV is switched off. 2) Energy saving feature • In TV mode all switched outlets are automatically switched off after 135 minutes if there is no RF, IR remote control signal or movement detected. • In Music mode all switched outlets are automatically switched off after Remove the backing from theisdouble Plug TAV-Link cable intoRF, theIR HDMI 8 the hours if there is no remote control signal or movement sided tape on the back of the portdetected. on the TV if you have a smart TV multi-sensor & affix to or near the TV. The multi-sensor must be connected to the APS+ and RF or IR signal from any remote must be received to switch on the switched outlets. surge ground swiched always senso switched switched surge The resettable switch must be at the reset position. dvd ground No power to outlets amplifier have power to them into the always-on outlets. DVR and set-top boxes. What AVEg. equipment should I plug into the switched outlets? The TV must be plugged into the green outlet labelled < tv >. Plug in devices such as the following to the remaining switched outlets: • Blu-ray, DVD and CD player • Amplifiers Step 5 - OPTIONAL Step 6 • Game consoles without a HDD • Home theatre speaker systems PowerStrip+ Solution Step 4 game console What AV equipment should I plug into the grey always on outlets? Plug in Audio Visual (AV) equipment that need constant power for recording features, timers and program guides such as: < tv > • TiVo • DVD recorders always on • Hard drives < tv >switched • Digital receivers • Set-top boxes Plug in devices that always TV must be plugged into this outlet. • Game console withshould a HDD Outlet Problem Step < tv > What can I plug into the APS+? Step 1 any object other than a plugStep 2 APS+ outlets. Never insert into the The APS+ is designed for use with indoor AV equipment. Do not use outdoors. Never use the APS+ for appliances other than AV equipment, such as a fridge, electric kettle, electric oven or microwave. Never use the APS+ for power tools such as power drills, bench saws and other power tools. or HDMI connected peripherals. 7 Advanced cable box FAQ Installation The icons on the outlet strip serve ONLY as examples of home The TV peripherals switch entertainment devices do thatnot can be off when into the TV is off outlets. For plugged these example, a DVD may be plugged into any of the four outlets as they all operate the same. Alternatively, press the button on the multi-sensor to switch on switched outlets manually. Make sure that the TV is plugged into the outlet with the green TV Plug the multi-sensor into the port on icon. the side of the power strip that looks like a phone jack. Make sure that the TV peripherals are connected to the green switched outlets (except for TV). Step 7 The switched outlets will switch off after the TV has been switched off for one minute. The multi-sensor is blinking on and off every 5 seconds This is a notification that your TV will shut off in 10 minutes. The TV keeps switching off after 30/60/120 minutes The power saving/countdown timer shuts off the TV and peripherals after 30/60/120 minutes if no RF/IR signal or motion is sensed. To reset the time for another 30/60/120 minutes, press a button on an RF/IR remote control or move in front of the multi-sensor. Plug the power strip into a grounded receptacle. The ground and surge lights will illuminate indicating proper grounding and surge protection is functional. surge ground switched www.tricklestar.com Advanced Powerstrip+ on Trouble Shooting No power at switched outlets switched subwoofer switched surge The resettable switch must be at the reset position. dvd ground No power to outlets amplifier have power to them into the always on outlets. DVR and set-top boxes. What AVEg. equipment should I plug into the switched outlets? The TV must be plugged into the green outlet labelled < tv >. Plug in devices such as the following to the remaining switched outlets: • Blu-ray, DVD and CD player • Amplifiers Step 5 - OPTIONAL Step 6 • Game consoles without a HDD • Home theatre speaker systems How does the APS+ save energy? The APS+ saves energy through: 1) Master control • All switched outlets are automatically switched off within one minute after the TV is switched off. 2) Energy saving feature • In TV mode all switched outlets are automatically switched off after 135 minutes if there is no RF, IR remote control signal or movement detected. • In music mode all switched outlets are automatically switched off after Remove backing from the double Plug the TAV linkif multi-sensor eight hours there is no into RF, TV IR remote controlthe signal or movement is sided tape on the back of the HDMI port if you have a smart TV or detected. www.tricklestar.com multi-sensor & fix to/near the TV PowerStrip+ Solution Step 4 game console What AV equipment should I plug into the grey always on outlets? Plug in Audio Visual (AV) equipment that need constant power for recording features, timers and program guides such as: < tv > • TiVo • DVD recorders • Devices always with on a hard disk drive (HDD) < tv >switched • Digital receivers • Set-top boxes Plug in devices always TV must be plugged into this outlet. • Game consolethat withshould a HDD Outlet Problem Step < tv > What can I plug into the APS+? Step 1 any object other than a plugStep 2 APS+ outlets. Never insert into the The APS+ is designed for use with indoor AV equipment. Do not use outdoors. Never use the APS+ for appliances other than AV equipment, such as a fridge, electric kettle, electric oven or microwave. Never use the APS+ for power tools such as power drills, bench saws and other power tools. HDMI connected peripherals. 7 Advanced cable box FAQ Installation The icons on the outlet strip serve ONLY as examples of home The TV peripherals switch entertainment devices do thatnotcan be off when into the TV is off outlets. For plugged these example, a DVD may be plugged into any of the four switched outlets as they all operate the same. The multi-sensor must be connected to the APS+ and RF or IR signal from any remote must be received to switch on the switched outlets. surge ground swiched senso Alternatively, press the button on the multi-sensor to switch on switched outlets manually. Make sure that the TV is plugged into the outlet with the green TV Plug the multi-sensor into the port on icon. the side of the power strip that looks like a phone jack. Make sure that the TV peripherals are connected to the green switched outlets (except for TV). Step 7 The switched outlets will switch off after the TV has been switched off for 1 minute. The multi-sensor is blinking on and off every 5 seconds This is a notification that your TV will shut off in 10 minutes. The TV keeps switching off after 30, 60, 120 minutes The power saving / countdown timer shuts off the TV and peripherals after 30 / 60 / 120 minutes if no RF/IR signal or movement is sensed. To reset the time for another 30 / 60 / 120 minutes, press a button on an RF/IR remote control or move in front of the multi-sensor. Plug the power strip into a grounded receptacle. The ground and surge lights will illuminate - indicating proper grounding and surge protection is functional. always Advanced Powerstrip+ on Operation - TV Mode Product Overview Step 1 Energy Saving ON 4 5 6 Press power on TV remote control to turn on TV. Step 3 Step 4 10 Power Connection The Product must only be plugged into a grounded receptacle for surge User Switches On protection to operateTVcorrectly. All connected devices should be plugged directly into the Product. Use of an extension cord, adaptor or other powerstrip in conjunction with the Product will void all warranties. Sensor/RJ11 RF +Port IR Remote Control Button Detected? Plug the RF/IR &Press motion multi-sensor into this port. There connector is inserted correctly. Yes will be a soft audible ‘click’ when the No Surge LED Next 15, 30, 60 min Countdown When illuminated, it indicates that the surge protection is functioning normally. Timer Starts If this LED illuminates red or extinguishes at any time, the Product was RF/IR Or Movement sacrificed to protect Detected your devices and must be replaced. Yes No Ground LED ALERTS START When illuminated, it indicates that the Product is correctly grounded. 10 min Before Countdown Timer Expirycontact an If not illuminated, there is a grounding problem and you must TV + Peripherals electrician to properly ground willSounds not work Buzzer 3X with an Switch Off the socket. Surge protection LED Flashes improperly grounded outlet. Switch On www.tricklestar.com 15, 30, 60 min Countdown Timer Starts Terms 6 Switched Outlets LED OFF Use peripheral RF/IR remotes to turn on peripherals as needed. PowerStrip+ RF/IR + Movement Multi-Sensor The Zigbee multi-sensor is connected to the powerstrip via the RJ11 port User Presses RF/IR marked “sensor.” Mount the ZigBee multi-sensor on the underside of the TV, Remote Control near the IR receiver on the TV (typically located next to the TV's power on/off button). The multi-sensor must be located within line of sight of where you normally use your remote controls. Switched Outlets Press any button on TV remote control to turn on the switched outlets. Outlet Step 2 7 Advanced When done watching TV, press the power button on the TV remote control to switch off the TV. All switched outlets will then automatically turn off within one minute. that thetransmitted switched outlets are receiving IR When illuminated, it- indicates Infrared signal, by a remote control power. - Multi-sensor senses for an IR command IR Signal Sensor Resettable Circuit 7 Sensor - Breaker Multi-sensor uses passive Infrared sensing to PIR All outlets on the Product are protected. If the surge, ground, and switched detect movement connected devices are notcontrol receiving power, - Radio and/or frequency, transmitted by a remote RF LEDs are not illuminated switch the circuit breaker to activate power. Movement - Movement detected by PIR Countdown Timer - Time before the switched outlets are automatically 8 Always-On Outlets switched off Equipment that requires continuous power should be plugged into the - 30 minutes / 60 minutes (default) / 120 minutes Countdown Period always-on outlets. - Red LED located in multi-sensor LED - When IR or movement is sensed, the LED will flash 9 < tv > Outlet Buzzer Buzzer located in the multi-sensor The outlet marked-is the control outlet and includes true RMS power measurement. IMPORTANT Countdown Timer Operation THE PLUGGED INTO THIS OUTLET For theTV firstMUST 15 / 30BE / 60 minutes - the multi-sensor senses for RF/IR only For the next 15 / 30 / 60 minutes - the multi-sensor senses for RF/IR signal or 10 movement Switched Outlets After 30 / is 60no / 120 if no RF/IR or movement has been If there RF,minutes IR, or motion detected, these outlets will switch off. sensed the switched outlets willl switch off automatically. Advanced Powerstrip+ Operation - TV Mode Product Overview Step 1 Energy Saving Step 2 ON 4 5 6 Power Connection User Switches TV Onbe plugged into a grounded receptacle for surge The Product must only protection to operate correctly. All connected devices should be plugged directly into the Product. Use of an extension cord, adaptor or other 15/30/60 Min Countdown Timer powerstrip in conjunction Starts with the Product will void all warranties. Press Detected? Sensor/RJ11 Port Plug Yes the RF / IR + Movement multi-sensor No into this port. There will be a soft audible ‘click’ when the connector is inserted correctly. Surge LEDNext 15/30/60 Min Countdown Timer Starts When illuminated, it indicates that the surge protection is functioning RF/IR or Motion normally. If this LED illuminates red or extinguishes at any time, the Detected Product was sacrificed to protect your devices and must be replaced. Yes No Step 4 OFF Use peripheral RF/IR remotes to turn on peripherals as needed. www.tricklestar.com RF + IR Remote Control Button ALERTS START 10 Min Before Countdown Ground LED Timer Expiry When illuminated, indicates that the Product is correctly grounded. TV &itPeripherals Buzzer Sounds 3X Switch Off If not illuminated, there is a grounding problem and you contact an LEDmust Flashes electrician to properly ground the socket. Surge protection will not work Terms with an improperly grounded outlet. 10 PowerStrip+ RF/IR + Movement Multi-Sensor User Presses RF/IR The ZigBee multi-sensor is connected to the powerstrip via the RJ 11 port Remote Control - marked “sensor”. Mount the ZigBee multi-sensor on the underside of the TV, near to the IR receiver on the TV. Typically located next to the TV Switched Outlets power on/off button. The multi-sensor must be located within line of sight Switch On of where you normally use your remote controls. Press power on TV remote control to turn on TV. Step 3 Outlet Press any button on TV remote control to turn on the switched outlets. 7 Advanced When done watching TV press the power button on the TV remote to switch off the TV. All switched outlets will then automatically turn off after 1 minute. - Infrared signal, transmitted by a remote control IR 6 Signal Switched Outlets - LED Multi-sensor senses for an IR command IR Sensor - Multi-sensor When lit, it indicates that the Outlets powered. uses are passive Infrared sensing to PIR Sensor detect movement 7 Resettable Circuit Breaker - Radio frequency, transmitted by a remote control RF Provides protection for all Outlets on the product. If no devices are Motion - Motion detected by PIR powered or LEDs- lit, press the the circuit breaker to activate power. Countdown Timer Time before switched outlets are automatically switched off 8 Always On Outlets - 30/60/120 minutes (default - 60 min.) Countdown Period Outlets remain ON all the time. - Red LED located in multi-sensor LED - When IR or motion is sensed, the LED will flash 9 < tv > Outlet - Buzzer located in the multi-sensor Buzzer The Outlet includes True RMS Power Measurement outlet for TV. IMPORTANT Countdown Timer THE TV MUST BEOperation PLUGGED INTO THIS OUTLET For the first 15/30/60 minutes - the multi-sensor senses for RF/IR only. the next 15/30/60 10 For Switched Outletsminutes - the multi-sensor senses for RF/IR signal or motion. Switched off if there is no RF, IR or movement is detected, or if the TV is Ifswitched no RF/IR or motion has been sensed during the 30/60/120 minute countdown off. period, the switched outlets will switch off automatically. Advanced Powerstrip+ Operation - Music Mode Step 1 Operation Countdown Timer Setting If any RF/IR signal is detected, the countdown timer period will automatically reset for another eight hours. If the TV is switched on during music mode, the Advanced PowerStrip+ will switch to TV mode. Operation RF Remote Control and Pairing A blue LED will flash for a period of 15 seconds - indicating the multi-sensor is in pairing mode. www.tricklestar.com The sensor has a default buzzer notification that will sound three times during the 10 minute countdown timer period. To configure the countdown timer, press and hold the button for 10 seconds until the red LED illuminates. Then press: • Once for 30 minutes • Twice for 60 minutes • Three times for 120 minutes To disable the audible notification, press and hold the button for 10 seconds until the red LED illuminates, then press the button four times. The red LED will flash four times to confirm the countdown timer buzzer has been disabled. After countdown timer is set, the LED will flash the number of times that timer has been set to. Press power on all music related devices to switch them on. Quickly press the pinhole pairing button located on the back of the multi-sensor to trigger the pairing process. PowerStrip+ Note If the TV is not switched on at any time in between, all switched outlets will turn off after eight hours. Step 1 Outlet Step 1 Note Press any button on AV receiver or DVD/CD player remote control to turn on the switched outlets. 7 Advanced Step 2 Place the RF remote control near the sensor (within two inches) and press the 0 key on the remote until the red LED on the sensor illuminates. Repeat with other RF remote controls (up to four). Operation Delete Paired RF Remote Control Address Step 1 Press and hold the pin-hole pairing button for five seconds. Blue LED will illuminate for one second - indicating all paired remote control addresses have been erased. Advanced Powerstrip+
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2016:01:25 08:51:08+08:00 Creator : Adobe Illustrator CS5 GTS PDFX Version : PDF/X-4 Modify Date : 2016:01:28 11:44:51+08:00 Trapped : False XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2016:01:28 11:44:51+08:00 Creator Tool : Adobe Illustrator CS5 Format : application/pdf Title : DS TS1811_5 Jan 2016 Document ID : uuid:ee5cb90e-1cd4-4277-9651-fd5dd2a7abf1 Instance ID : uuid:12d52adb-3454-45bc-b3d9-4bee4bc1a8d5 Producer : Adobe PDF library 9.90 Page Count : 11EXIF Metadata provided by EXIF.tools