Tagsys MEDIOS004EVAL Medio S004 EVM Evaluation Board User Manual Medio S004 EVM

Tagsys S.A. Medio S004 EVM Evaluation Board Medio S004 EVM

Manual

Download: Tagsys MEDIOS004EVAL Medio S004 EVM Evaluation Board User Manual Medio S004 EVM
Mirror Download [FCC.gov]Tagsys MEDIOS004EVAL Medio S004 EVM Evaluation Board User Manual Medio S004 EVM
Document ID759083
Application IDYVhDfNXWw0YuROyJBtUWaA==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize81.98kB (1024716 bits)
Date Submitted2007-02-14 00:00:00
Date Available2007-02-15 00:00:00
Creation Date2007-01-16 12:12:55
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2007-01-16 12:18:21
Document TitleMedio S004 EVM
Document CreatorAcrobat PDFMaker 6.0 pour Word
Document Author: Michael Colantoni

Medio S004 EVM
User's Guide
Revision 1.1
October 2006
Medio S004 EVM
Publishing Information
Disclaimer and Limitation of Liability
All information herein is either public information or is the property of and owned solely by TAGSYS who shall have and
keep the sole right to file patent applications or any other kind of intellectual property protection in connection with such
information.
Nothing herein shall be construed as implying or granting to you any rights, by license, grant or otherwise, under any
intellectual and/or industrial property rights of or concerning any of TAGSYS’ information.
This document can be used for informational, non-commercial, internal and personal use only provided that:
ƒ
the copyright notice below, the confidentiality and proprietary legend and this full warning notice appear in all copies.
ƒ
this document shall not be posted on any network computer or broadcast in any media and no modification of any
part of this document shall be made.
Use for any other purpose is expressly prohibited and may result in severe civil and criminal liabilities.
The information contained in this document is provided “AS IS” without any warranty of any kind. Unless otherwise
expressly agreed in writing, TAGSYS makes no warranty as to the value or accuracy of information contained herein.
The document could include technical inaccuracies or typographical errors. Changes are periodically added to the
information herein. Furthermore, TAGSYS reserves the right to make any change or improvement in the specifications
data, information, and the like described herein, at any time.
Therefore TAGSYS assumes no liability and is not responsible for customer applications or product or software which
include TAGSYS products.
TAGSYS HEREBY DISCLAIMS ALL WARRANTIES AND CONDITIONS WITH REGARD TO THE INFORMATION
CONTAINED HEREIN, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT. IN NO EVENT SHALL TAGSYS BE LIABLE, WHETHER
IN CONTRACT, TORT OR OTHERWISE, FOR ANY INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR ANY
DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DAMAGES RESULTING FROM LOSS OF USE,
DATA, PROFITS, REVENUES, OR CUSTOMERS, ARISING OUT OF OR IN CONNECTION WITH THE USE OR
PERFORMANCE OF INFORMATION CONTAINED IN THIS DOCUMENT.
TAGSYS does not and shall not warrant that this product/system/equipment will be resistant to all possible attacks, and
shall not incur, and disclaims, any liability in this respect. Even if each product is compliant with current security
standards in force on the date of their design, security mechanisms' resistance necessarily evolves according to the
state-of-the-art in security and notably under the emergence of new attacks. Under no circumstances shall TAGSYS be
held liable for any third party actions, and in particular in case of any successful attack against systems or equipment
incorporating TAGSYS products.
TAGSYS disclaims any liability with respect to security for direct, indirect, incidental or consequential damages that result
from any use of its products. It is further stressed that independent testing and verification by the person using the
product is particularly encouraged, especially in any application in which defective, incorrect, or insecure functioning
could result in damage to persons or property, denial of service, or loss of privacy.
Pictures in this document are not representative of the final product. In particular, connectors’ availability is
subject to local radio regulations. All the pictures are related to European product.
© 2000-2006 TAGSYS. All rights reserved.
Microsoft, Visual C++, Windows, and Windows NT are either registered trademarks or trademarks of Microsoft
Corporation in the U.S.A. and/or other countries.
I-Code is a registered trademark of Philips.
Tag-It is a registered trademark of Texas Instruments.
Printed in France.
TAGSYS – 180 Chemin de St Lambert, 13821 LA PENNE SUR HUVEAUNE, France.
Tel: +33 (0)4.91.27.57.00 / Fax: +33 (0)4.91.27.57.01
Document Reference: 12125A1
2/33
Revision 1.1
October 2006
Medio S004 EVM
Read This First
Welcome to the TAGSYS range of products operating at the 13.56 MHz frequency. This range of
products is used to implement high-quality RFID systems for demanding applications.
This document provides information about how to install and use the Medio S004 EVM (Evaluation
Module).
Audience
This document requires familiarity with RFID technology. It is intended for people in charge of
installing and using the product.
Conventions
Symbol
Meaning
CAUTION: A note that advises users that a specific action could result in the loss of data or
damage the hardware.
WARNING: A note that advises users that a specific action may result in physical harm.
A note that provides additional information that helps the user perform a task or obtain the
best performance from the product.
If you need assistance
Please contact your nearest TAGSYS sales representative or the TAGSYS welcome desk at:
Telephone:
+33 (0)4 91 27 57 00
Fax:
+33 (0)4 91 27 57 01
E-Mail:
info@tagsysrfid.com
Website:
http://www.tagsysrfid.com
Contact for Comments
We welcome your feedback to help us provide high quality documentation.
For technical comments, please contact our welcome desk:
Telephone:
Fax:
E-Mail:
+33 (0)4 91 27 57 00
+33 (0)4 91 27 57 01
info@tagsysrfid.com
Please remember to quote the Document Reference Number 12125A1, your job title and your
company.
October 2006
Revision 1.1
3/33
Medio S004 EVM
Quality Issues
TAGSYS implements stringent quality controls at all stages of its manufacturing process. However,
should you find a defect with this product, please notify your TAGSYS Quality Service
representative using the dedicated Product Return Form.
Telephone:
Fax:
4/33
+33 (0)4 91 27 57 36
+33 (0)4 91 27 57 02
Revision 1.1
October 2006
Medio S004 EVM
Table of Contents
PUBLISHING INFORMATION __________________________________________________________ 2
DISCLAIMER AND LIMITATION OF LIABILITY __________________________________________________ 2
READ THIS FIRST ____________________________________________________________________ 3
AUDIENCE ____________________________________________________________________________ 3
CONVENTIONS _________________________________________________________________________ 3
IF YOU NEED ASSISTANCE ________________________________________________________________ 3
CONTACT FOR COMMENTS _______________________________________________________________ 3
QUALITY ISSUES _______________________________________________________________________ 4
FOR YOUR SAFETY _______________________________________________________________ 7
1.1 GENERAL USE ____________________________________________________________________ 7
1.2 CARE AND MAINTENANCE ___________________________________________________________ 7
1.3 IMPORTANT SAFETY INFORMATION ____________________________________________________ 8
1.3.1 OPERATING ENVIRONMENT ________________________________________________________ 8
CERTIFICATION___________________________________________________________________ 9
2.1 OCCUPATIONAL HEALTH ____________________________________________________________ 9
2.2 REGULATORY NOTICES _____________________________________________________________ 9
2.2.1 IN EUROPE (CE AND RTTE DIRECTIVES) _____________________________________________ 9
2.2.2 IN USA (FCC DIRECTIVE)_________________________________________________________ 10
2.2.3 IN CANADA _____________________________________________________________________ 10
2.3 ROHS AND WEEE DIRECTIVES _____________________________________________________ 11
2.3.1 ROHS (RESTRICTION OF THE USES OF CERTAIN HAZARDOUS SUBSTANCES) _______________ 11
2.3.2 WEEE (WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT) ____________________________ 11
3.1
3.2
3.3
3.4
INTRODUCTION __________________________________________________________________ 12
EVM DESCRIPTION _______________________________________________________________ 12
MEDIO S004 READER DESCRIPTION _________________________________________________ 12
MEDIO S004 EVM DELIVERY _______________________________________________________ 13
MEDIO S004 EVM KEY FEATURES___________________________________________________ 13
GETTING STARTED WITH THE EVM _______________________________________________ 16
4.1 INSTALLING THE EVM PRODUCT _____________________________________________________ 16
4.2 INSTALLING EVM DRIVERS _________________________________________________________ 16
4.2.1 WINDOW 98® USB DRIVERS INSTALLATION __________________________________________ 17
4.2.2 WINDOWS XP USB DRIVERS INSTALLATION __________________________________________ 17
TECHNICAL INFORMATION ON THE EVM __________________________________________ 19
5.1 MONITORING MEDIO S004 EVM DIGITAL SIGNALS______________________________________ 19
October 2006
Revision 1.1
5/33
Medio S004 EVM
5.2 A-VSA ANTENNA DESCRIPTION _____________________________________________________ 20
5.3 PLUGGING ANOTHER ANTENNA TO THE SMA CONNECTOR _______________________________ 21
S004 EXPLORER _________________________________________________________________ 22
6.1 INSTALLING S004 EXPLORER _______________________________________________________ 22
6.2 RUNNING S004 EXPLORER _________________________________________________________ 24
6.2.1 USB COMMUNICATION ___________________________________________________________ 24
6.3 READING AND WRITING A TAG ______________________________________________________ 25
STAND-ALONE MODE ____________________________________________________________ 26
7.1 STAND-ALONE MODE FEATURES ____________________________________________________ 26
7.1.1 CUSTOMIZED ASCII MESSAGE FORMAT _____________________________________________ 27
7.1.2 REPETITION OPTION _____________________________________________________________ 27
7.1.3 TRIGGER INPUT _________________________________________________________________ 28
7.1.4 OUTPUT SETTINGS ______________________________________________________________ 28
7.2 STAND-ALONE MODE SETTINGS _____________________________________________________ 29
7.2.1 USING S004 EXPLORER __________________________________________________________ 29
7.3 DISABLING STAND-ALONE MODE ____________________________________________________ 30
WARRANTY CONDITIONS ________________________________________________________ 31
8.1 WARRANTY ______________________________________________________________________ 31
8.2 WARRANTY EXCLUSIONS __________________________________________________________ 31
8.2.1 GENERAL PROVISIONS ___________________________________________________________ 32
8.2.2 HOW TO RETURN DEFECTIVE PRODUCTS ____________________________________________ 32
6/33
Revision 1.1
October 2006
Medio S004 EVM
1 For Your Safety
1.1 General Use
The Medio S004 reader and EVM are designed to be reliable and to provide years of trouble-free
service.
Please observe the following general tips:
ƒ
Take care not to damage the components. When working with the device, use only
equipment that meet TAGSYS specifications.
ƒ
This device is not waterproof and should not be exposed to moisture.
ƒ
Protect the device from extreme temperatures. For example, do not place the device in a
windowed area where the sun may cause extreme temperatures, and keep it away from
heaters and other heat sources.
ƒ
Do not store or use the device in any location that is extremely dusty, damp, or wet.
1.2 Care and Maintenance
This device is a product of superior design and should be handled with care. The suggestions
below will further increase the lifetime of this device.
ƒ
Keep the device and all parts and accessories out of the reach of small children.
ƒ
Keep the device dry. Precipitation, humidity and liquids contain minerals that will corrode
electronic circuits.
ƒ
Do not use or store the device in dusty, dirty areas. Its moving parts can be damaged.
ƒ
Do not store in hot areas. High temperatures can shorten the life of electronic devices,
damage batteries and warp or melt certain plastics.
ƒ
Do not store in cold areas. When the device warms up (to its normal temperature), moisture
can form which may damage electronic circuit boards.
ƒ
Do not attempt to modify the device. Non-professional handling of the device may damage
it.
ƒ
Handle the device with care. Shocks may break internal circuit boards.
ƒ
If the device or any accessory are not working properly, take it to your nearest qualified
TAGSYS representative.
October 2006
Revision 1.1
7/33
Medio S004 EVM
1.3 Important Safety Information
1.3.1 Operating Environment
When connecting the device or any accessory to another device, read its user’s guide for detailed
safety instructions. Do not connect incompatible products.
8/33
Revision 1.1
October 2006
Medio S004 EVM
2 Certification
2.1 Occupational Health
TAGSYS EVM has been designed and tested to be in conformity with the European Standard EN
50364 “Limitation of human exposure to electromagnetic fields from devices used in Electronic
Article Surveillance (EAS), Radio Frequency Identification (RFID) and similar applications” in
conjunction with the European Standard EN 50357 describing how to evaluate the exposure level.
The EVM has been also designed to be in conformity with Specific Absorption Rate (SAR)
standards according to FCC CFR47 and EN 50392:2004 recommendations.
Modification of any part of TAGSYS System is prohibited without the written consent of
TAGSYS. Unauthorized modifications may void the certificate of conformity of the equipment
and will also void the TAGSYS certificate of warranty.
2.2 Regulatory Notices
An RFID system typically composed of an RF emission device connected to an antenna such as
the Medio S004 EVM comprising the Medio S004 reader and the EVM with its embedded antenna.
Every RFID system is subject to national regulations that may differ by country.
The EVM is meant to be used solely for evaluation purposes. It is the responsibility of the system
integrator to ensure that the final solution meets all regulatory requirements.
The Medio S004 EVM product is primary intended for evaluation usage and as such is not
supposed to be integrated. Nevertheless it is the responsibility of the CIT (Certified
Integrators by TAGSYS) to integrate the Medio S004 EVM as described in this Integrator’s
Guide.
If the Medio S004 EVM is integrated in custom solution, it is the sole responsibility of the
manufacturer to obtain the required approvals for the customized product.
2.2.1 In Europe (CE and RTTE Directives)
The Medio S004 EVM complies (CE Declaration of Conformity granted) with the European EMC
directive.
The Medio S004 EVM complies with the requirements of the Telecommunication Terminal
Equipment Act (FTEG) and the RTTE Directive 1995/5/EC.
October 2006
Revision 1.1
9/33
Medio S004 EVM
2.2.2 In USA (FCC Directive)
Medio S004 EVM
WARNING TO USERS IN THE UNITED STATES
FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIO
INTERFERENCE STATEMENT 47 CFR Section 15.105(b)
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can
radiate radio frequency energy and if not installed and used in accordance with the instructions
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
▪
Reorient or relocate the receiving antenna.
▪
Increase the separation between the equipment and receiver.
▪
Connect the equipment into an outlet on a circuit different to that to which the receiver is
connected.
▪
Consult the dealer or an experienced radio/TV technician for help.
NO UNAUTHORIZED MODIFICATIONS
47 CFR Section 15.21
CAUTION: This equipment may not be modified, altered, or changed in any way without signed
written permission from TAGSYS SA. Unauthorized modification may void the equipment
authorization from the FCC and will void the TAGSYS warranty.
ANTENNA REQUIREMENT
47 CFR Section 15.203
CAUTION: This equipment must be professionally installed. The installer shall be responsible for
ensuring that only the supplied antenna is employed so that the limits in this part are not exceeded.
Non-professional installation or installation of the equipment with an improper antenna may void
the equipment authorization from the FCC and will void the TAGSYS warranty.
The Medio S004 EVM has been designed to comply with FCC 47 CFR Part 15 Rules.
Operation is subject to the following two conditions: (1) The system devices may not cause harmful
interference, and (2) The library system devices must accept any interference received, including
interference that may cause undesired operation.
2.2.3 In Canada
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel
brouilleur du Canada.
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations
10/33
Revision 1.1
October 2006
Medio S004 EVM
2.3
RoHS and WEEE Directives
2.3.1 RoHS (Restriction of the uses of certain Hazardous Substances)
TAGSYS certifies that this product is compliant with the European Directive 2002/95/EC for the
restriction in Electric and Electronic Equipments (RoHS) of the use of the following hazardous
substances:
•
Lead
•
Mercury
•
Cadmium
•
Hexavalent Chromium
•
Polybrominated biphenyl flame retardants
•
Polybrominated diphenyl ether flame retardants
This declaration is based on information provided by our suppliers and subcontractors.
2.3.2 WEEE (Waste Electrical and Electronic Equipment)
This product bears the selective sorting symbol for waste
electrical and electronic equipment (WEEE)
This means that this product must be handled pursuant to
European Directive 2002/96/EC in order to be recycled or
dismantled to minimize its impact on the environment.
For further information, please contact your local or regional
authorities.
October 2006
Revision 1.1
11/33
Medio S004 EVM
3 Introduction
3.1 EVM Description
The Evaluation Module (EVM) provided by Tagsys allows the OEM to test the reader before its
integration within their solution:
•
The EVM provides all necessary connections to perform tests and includes also an
embedded antenna.
•
The EVM is not meant to be integrated within a final solution; it is only intended to test
the performance of the Medio S004 reader.
•
The EVM is supplied with a foot print pattern that can be used to solder the Medio S004
reader to it.
3.2 Medio S004 Reader Description
TAGSYS Medio S004 reader is dedicated to Original Equipment Manufacturer (OEM) applications.
The Medio S004 reader is a Universal Short Range RFID reader designed to operate at 13.56 MHz
with any I-CodeTM EPC, I-CodeTM UID, I-CodeTM 1, and ISO 15693 compliant tags.
The Medio S004 reader’s technical features make it the ideal device for easy integration into
handheld computers and printers. It offers the following features on a small printed circuit board:
•
•
A high-performance radio processing unit operating at 13.56 MHz,
•
The Medio S004 reader is provided with solder pads to help its soldering fixation to the
EVM.
A digital processing unit that incorporates chip drivers and the anti-collision feature
depending on the type of chip.
Medio S004 EVM requires minimal computing power (host workstation) and communicates at high
speed, thanks to the TAGSYS enhanced communication protocol (STX-E) already used for the
Medio P101 series and the Medio L100/L200 readers.
The Medio S004 reader is fixed onto the EVM with help of screws and is electrically connected to
the EVM using the 10 pin Molex cable.
In case you were to solder the Medio S004 reader to the EVM, do not use the Molex Cable
connector.
12/33
Revision 1.1
October 2006
Medio S004 EVM
3.3 Medio S004 EVM Delivery
The Medio S004 EVM reader kit is supplied with the following items:
Table 1: Package Contents
Quantity
Item
Medio S004 reader mounted onto the EVM
CD-ROM including:
•
Medio S004 Integrator's Guide
•
Medio S004 Command Set
•
User-friendly Sx Explorer software provided for test and debug operations on
Windows® 9x, NT®, 2000 and XP platforms
•
Medio STX Windows® DLLs to facilitate the development your own applications on
Windows® Mobile platform
•
Medio STX Windows® DLL Programming Guide
•
One set of Microsoft® Visual C++® source code and executable samples using the
Medio STX Windows® DLLs
Welcome Letter / Product Return Form
3.4 Medio S004 EVM Key Features
Table 2: Medio S004 EVM Key Features
Description
Medio S004
Operating Frequency
Chip Compatibility
Serial Link
I/O
October 2006
13.56 MHz
ISO 15693 compliant
I-Code EPCTM
I-Code UIDTM
C270 (Philips I-CodeTM-1)
Asynchronous serial TTL (RS-232 compliant) or 3-wired Synchronous
1 input 1 Output
Revision 1.1
13/33
Medio S004 EVM
Figure 1: Medio S004 TAGSYS RFID Tag Reader and EVM Module
Molex Cable
Power Supply
Connector
USB
Connector
USB
RX/TX
LED
14/33
Com.
Mode
LED
Serial
Selector
Output
LED
Push
button for
Input
Monitoring
Connector
Revision 1.1
Medio
S004
reader
MCB coaxial
Cable
A-VSA
Antenna
SMA
Connector
October 2006
Medio S004 EVM
Table 3: Component Descriptions
Connector/Component
Description
Medio S004
RFID Reader
Power Supply
Connector
To plug the power supply to the EVM power connector.
USB Connector
To connect the USB cable and the other end to the host PC.
RX and TX USB LED
RX led flashes orange when the host is sending commands to the EVM
TX led flashes green when the reader is sending data to the host
This jumper selects the Synchronous / Asynchronous mode.
Serial Selector
Synchronous Mode
Asynchronous Mode
The jumper must be positioned before plugging in the power and USB
cables. To change the serial communication mode, you must unplug the
power and USB cables, change the jumper setting, and reconnect the
power and USB cables. The green communication mode LED is on
when synchronous serial mode is selected.
Push Button for input
When pushed provides +5V on the IN pin.
Output LED
This LED is ON (yellow) when +5V is present on the OUT pin.
Molex Cable
To connect the reader signals from the EVM to the S004 reader.
MCB Coaxial Cable
To connect the reader to its antenna
Monitoring Connector
This is used solely for monitoring the reader signals. See the Medio
S004 Integrator’s Guide for more information.
SMA Connector
External Antenna connector can be used to connect other antennas. (Be
sure to connect the antenna cable from the S004 RF coaxial connector
to the coaxial that is next to the SMA connector.) Carefully unplug the
RF Coaxial cable for the EVM antenna and connect it to the SMA
antenna receptacle near the SMA connector.
A-VSA
The built-in antenna has a RF coaxial connector which (when used) must
be connected to the S004 RF coaxial connector.
October 2006
Revision 1.1
15/33
Medio S004 EVM
4 Getting Started with the EVM
4.1 Installing the EVM product
1. Before any plugging takes place, please select the communication mode using the serial
selector.
Synchronous serial mode
Asynchronous serial mode
2. Plug both power supply and USB supply cables to the EVM.
If the Synchronous serial communication is selected, the green LED for Serial Communication
mode turns on.
DO NOT change the Serial Communication Selector until both power supply and USB cable
are unplugged or unpredictable result can occur.
4.2 Installing EVM drivers
At first connection to the PC USB port, Windows® will detect the TAGSYS Evaluation Board (for
Medio S004 reader) and will ask you for driver installation. USB drivers are located into the USB
Drivers folder on the product CD-Rom.
Two drivers must be installed:
16/33
Revision 1.1
October 2006
Medio S004 EVM
The first one is the direct driver, which provides direct access to USB device via a dynamic
link library (DLL).
The second one is the virtual COM port (VCP) driver. The VCP driver emulates a standard
PC COM port.
4.2.1 Window 98® USB Drivers Installation
Power up and connect your Medio S004 to a spare USB port on your PC. This should bring up a
“Building Driver Information Database” followed by the Windows Add New Hardware Wizard.
Click “Next” to proceed with the installation
ƒ
Select “Search for the best driver for your device” and then click “Next”
ƒ
Select “Specify a location” and click the Browse button to select the USB Drivers folder on
the Product CR-Rom. Once the files have been located, click “Next” to proceed with the
installation
ƒ
Click “Next” to install the device
ƒ
Windows® should then display a message indicating that the installation was successful.
Click “Finish” to complete the installation.
To confirm that the installation has completed successfully, open the Device Manager and select
“View devices by type”. The TAGSYS Medio S004 appears as a USB device connected to a USB
port
The next step is to install the VCP drivers.
Power up and connect your Medio S004 to a spare USB port on your PC. This should bring up a
“Building Driver Information Database” followed by the Windows Add New Hardware Wizard.
ƒ
Select “Search for the best driver for your device” and then click “Next”
ƒ
Select “Specify a location” and click the Browse button to select the USB Drivers folder on
the Product CR-Rom. Once the files have been located, click “Next” to proceed with the
installation
ƒ
Click “Next” to install the device
ƒ
Windows® should then display a message that the installation of the serial converter driver
was successful. The COM port emulation driver must now be installed. Click “Finish” to
complete the installation.
To confirm that the installation has completed successfully, open the Device Manager and select
“View > devices by type”. The TAGSYS Medio S004 appears as an additional COM port.
4.2.2 Windows XP USB Drivers Installation
Power up and connect your Medio S004 to a spare USB port on your PC. This will launch the
Windows Found New hardware Wizard
ƒ
Select “No, not this time” and click next to proceed with the installation
ƒ
Select “Install from a list or specific location (Advanced)” and then click “Next”
ƒ
Select “Search for the best driver in these locations” and click the Browse button to select
the TAGSYS USB Drivers folder on the Product CR-Rom. Then click “Next” to proceed.
ƒ
Windows should then display a message indicating that the installation was successful.
Click Finish to complete the installation
To confirm that the installation has completed successfully, open the Device Manager and select
“View > Devices by type”. The TAGSYS Medio S004 appears as a USB device connected to a
USB port.
October 2006
Revision 1.1
17/33
Medio S004 EVM
The next step is to install the VCP drivers.
Power up and connect your Medio S004 to a spare USB port on your PC. This will launch the
Windows Found New Hardware Wizard
ƒ
Select “No, not this time” and click next to proceed with the installation
ƒ
Select “Install from a list or specific location (Advanced)” and then click “Next”
ƒ
Select “Search for the best driver in these locations” and click the Browse button to select
the USB Drivers folder on the Product CR-Rom. Then click “Next” to proceed.
ƒ
Windows should then display a message indicating that the installation was successful.
Click Finish to complete the installation. This has installed the serial converter. The COM
port emulation driver must be installed after this has completed.
ƒ
After clicking “Finish”, the Found New Hardware Wizard will continue by installing the COM
port emulation driver.
To confirm that the installation has completed successfully, open the Device Manager and select
“View > Devices by type”. The TAGSYS Medio S004 appears as an additional COM port.
18/33
Revision 1.1
October 2006
Medio S004 EVM
5 Technical Information on the EVM
We recommend you to first read the Medio S004 Integrator’s Guide for details on the Medio
S004 reader.
5.1 Monitoring Medio S004 EVM Digital Signals
Signals sent to the Medio S004 can be monitored connecting probes (oscilloscope) to the
Monitoring Connector as described below:
Figure 2: Monitoring Connector
Pin
Pin
Signal
GND
OUT
IN
RX
TX
CS
COMSELECT
DO NOT drive any signal with a digital level on this connector. The EVM may be damaged.
October 2006
Revision 1.1
19/33
Medio S004 EVM
Example of an asynchronous communication (SetIO command – 115200 Bps)
Example of a synchronous communication (SetIO command)
5.2 A-VSA Antenna description
The A-VSA is a 13.56MHz resonant antenna designed according to the following schematic:
Cs
Cp
Parameter
Nominal working frequency
Number of 0,2mm turns
Internal turn dimensions
External turn dimension
PCB inductance (L)
Damping Resistor (Rp)
Parallel Capacitor (Cp)
Serial Capacitor (Cs)
Q factor
20/33
Rp
Value
13,560MHz
22mmx37mm
39mmx54mm
2400nH
15000 Ohm
~39pF
~15pF
28
Revision 1.1
October 2006
Medio S004 EVM
5.3 Plugging another antenna to the SMA connector
Other antennas may be plugged to the Medio S004 EVM antenna output using a MCB coaxial
cable.
The SMA connector may also be used to convert the MCB connector to a standard one, and plug a
SMA cable to another antenna. To do so, unplug the MCB cable from the A-VSA and connect it to
the SMA connector as shown below:
Depending on your local radio regulations, you will have to solder a SMA connector on the
dedicated footprint by yourself but this will void the TAGSYS certification.
Using another antenna will void any of the certifications (CE or FCC). You will have to certify
your final integrated system according to local radio regulations. To help you certify your final
integrated system, radio test report is included on the CDROM (“Medio S004 – Radio Test
Reports” folder)
October 2006
Revision 1.1
21/33
Medio S004 EVM
6 S004 Explorer
The Medio S004 reader is delivered with the Sx Explorer software tool intended to easily setup the
reader, test it and perform reading and writing operations according to the antenna and type of tag
to be used. In addition, S004 Explorer can display additional information such as the Product
Reference and Firmware version and revision. This section describes how to start with Sx
Explorer.
6.1 Installing S004 Explorer
To install S004 Explorer software, insert the product CD-ROM into the disk drive on your PC and
run the Setup from the “Medio S004 - Software Suite\ Tools\S004 Explorer 1-0-1 folder and click
“Next”
Click the “Browse” button to choose a specific installation folder.
22/33
Revision 1.1
October 2006
Medio S004 EVM
Once the correct folder is selected, click “Next”
Click “Next” to start the installation process. A shortcut will be created on your desktop and a
program group will be created in the start menu.
October 2006
Revision 1.1
23/33
Medio S004 EVM
6.2 Running S004 Explorer
6.2.1 USB Communication
Before launching S004 Explorer, be sure which COM port number is assigned to the Tagsys EVM
Module. Open the Device Manager and select “View > Devices by type”.
The COM port number is assigned to the Tagsys EVM Module.
Power up the Medio S004 EVM and connect the USB cable to both your PC and the Medio S004
EVM. Run Sx Explorer. If the following window is displayed click yes.
Open the Communication Settings window (CTRL+C) and check the type of the media, the COM
port number and the communication speed. The default communication speed for the Medio S004
EVM is 115200 Baud.
Click OK. Now S004 Explorer is ready to communicate with your Medio S004 EVM.
24/33
Revision 1.1
October 2006
Medio S004 EVM
6.3 Reading and Writing a Tag
S004 Explorer includes a Wizard function used to guide you each step of how to read or program a
tag. We recommend using the Wizard function for users who are not familiar with all S004 Explorer
capabilities and features.
Click on the Wizard icon (magic wand) to open the S004 Explorer Wizard dialog box.
Select the type of chip from the drop–down menu or place the tag on the antenna and click the
“Detect “button to automatically detect the tag type.
Select the desired operation (Read or Write) and then click OK. All the necessary windows to
perform the desired action will be automatically displayed on the screen.
For more details concerning S004 Explorer, select the info menu and click Help (CTRL+H) to
display the S004 Explorer User’s Guide.
October 2006
Revision 1.1
25/33
Medio S004 EVM
7 Stand-alone Mode
Stand-alone Mode is designed to use the reader without using any command set. While in Standalone mode, the reader only performs tag reading operations.
The reader sends the tag ID to the Host System using ASCII protocol via the Reader-to-Host
interface.
ASCII protocol is used in order to provide hexadecimal data that can be read by a variety of
terminal programs (e.g. Microsoft® HyperTerminal).
7.1 Stand-alone Mode Features
Table 4 lists the available Stand-alone mode features.
Table 4: Available Features in Stand-alone Mode
Features
Medio S004
ISO 15693 compliant
I-Code EPCTM
I-Code UIDTM
C270 (Philips I-CodeTM-1)
Customized tag type reading
compatibility
(depending on downloaded
application firmware)
Serial Communication Type
Asynchronous serial TTL (RS-232 compliant) or 3-wired Synchronous
Repetition Option
Available
Customized ASCII message
format
STX/ETX Characters
Header String
Chip Description String
ID String (variable length)
End of Message String
Input Trigger
Available
Output for active trigger
information
Available
Output for tag reading information Available
26/33
Revision 1.1
October 2006
Medio S004 EVM
7.1.1 Customized ASCII Message Format
When a tag is read, its data are transmitted to the host in the form of an ASCII character frame.
I-Code
EPC
2 to 24 characters
I-Code
UID
2 to 16 characters
End of Text
ID
Chip
Description
String
“TAGSYS-“
Chip name
(Default)
End of
Message
String

(0x02)
Description
Header
String
Start of Text
Table 5: Customized ASCII Message Format (TAGSYS RFID Tag is read)

(Default)

(0x03)
Optional
Optional
C270
(Philips I- 2 to 16 characters
Code™-1)
ISO15693
S004
Optional
Optional
Optional
2 to 16 characters
Required
Medio S004 reader can decode all chips in Stand-alone mode. Only the ID field is required in the
return ASCII message. All other fields are optional. The ID field length is programmable; the default
lengths are given in Table 6.
Table 6: Default ID Field Lengths
Chip Type
Default ID Field Length
I-Code EPC
24 (Total memory)
I-Code UID
10 (Memory area 1)
C270 (Philips I-Code™) chip
16 (Block 0 and Block 1)
ISO 15693 compliant
16 (UID)
7.1.2 Repetition Option
The reader constantly attempts to read any chips present in the field. When a chip ID is detected,
the reader can send the information to the host in one of 2 modes:
1. In “Repeated Read” mode, the reader returns a chip’s ID to the host with each successful
read operation.
2. In “Read Once” mode, the reader only returns the ID of a chip if the previous read
corresponds to a different chip, or if all reading attempts have failed 4 times (this feature
makes it possible to detect a chip’s potential exit out of the field).
October 2006
Revision 1.1
27/33
Medio S004 EVM
7.1.3 Trigger Input
When the trigger capability is enabled, a trigger state is used to start and stop the RF scanning.
The trigger is connected to the input of the reader.
Depending on the reply settings of the trigger, the ASCII message can be sent during the trigger
activity (Repeated Read mode and Read Once mode are available) or at the end of the trigger. In
this last case, a message is always sent to the host system:
ƒ
if a tag has been read, the message contains its ID,
ƒ
if no tag has been read, the message contains a No Message string (that can be defined)
as shown in Table 7.
Table 7: Customized ASCII Message Format (TAGSYS RFID Tag is not read)
Start of Text
Header String
No Tag Found
String
End of Message
String
End of Text
Description

(0x02)
“TAGSYS-“
(Default)
“????????“
(Default)

(Default)

(0x03)
Size
character
0 to 16
characters
0 to 16
characters
0 to 16
characters
character
Status
Optional
Optional
Required
Optional
Optional
7.1.4 Output Settings
The output of the reader can be used to monitor the trigger activity or the successful reads.
28/33
Revision 1.1
October 2006
Medio S004 EVM
7.2 Stand-alone Mode Settings
Stand-alone Mode can be set in one of two ways while the reader is in Normal Operating mode
•
Using the Sx Explorer software provided with the reader
•
Using “Set Stand-alone Mode” command followed by a “Reset Reader” command. For
more information, refer to the Medio S004 Command Set document.
7.2.1 Using S004 Explorer
Run the S004 Explorer software. In the Settings menu, select General Reader Settings
Enable
Standalone
mode at next
power on
October 2006
Revision 1.1
29/33
Medio S004 EVM
7.3 Disabling Stand-alone Mode
The Medio S004 can be reset in Standard mode in one of two ways as described below:
•
Use the S004 Explorer software provided with the reader and click Yes when the following
window is displayed
•
Send the 'S' character using a console interface (for example, HyperTerminal).
•
Unplug both power supply and USB cable. Change the Serial Communication Selector to
Synchronous mode. Plug both power supply and USB cables. Then revert to Asynchronous
mode if necessary by unplugging both power supply and USB cables and changing the
Serial Communication Selector again.
30/33
Revision 1.1
October 2006
Medio S004 EVM
8 Warranty Conditions
8.1 Warranty
TAGSYS warrants that this Product shall comply with the functional specifications set forth herein
for a period of one year from the date of delivery to the Buyer.
This warranty is valid for the original Buyer of the Product and is not assignable or transferable to
any other party.
TAGSYS cannot be responsible in any way for, and disclaims any liability in connection with the
operation or performance of:
ƒ
any product in which the Product is incorporated;
ƒ
any equipment not supplied by TAGSYS which is attached to or used in connection with the
Product; or
ƒ
the Product with any equipment
This warranty does only cover the Product to the exclusion of any such other equipment.
Optimal operation and performance of the Product are obtained by using TAGSYS’ readers, by
applying TAGSYS installation guidelines and by having your installation reviewed by a TAGSYS’
technical consultant.
TAGSYS warranty does not cover the installation, maintenance or service of the Product and is
strictly limited to the replacement of Products considered as defective by TAGSYS and returned
according to the return procedure defined below; in such case, TAGSYS will, at TAGSYS’ option,
either replace every defective Product by one new Product or refund the purchase price paid by
Buyer to TAGSYS for the defective Product.
8.2 Warranty Exclusions
ƒ
Defects or damages resulting from storage of the Product under conditions which do not
comply with TAGSYS specifications or normal usage
ƒ
Defects or damages resulting from use of the Product in abnormal conditions (abnormal
conditions being defined as any conditions exceeding the ones stated in the product
specifications).
ƒ
Defects or damages from misuse, accident or neglect.
ƒ
Defects from improper testing, operation, maintenance or installation.
ƒ
Defects from alteration, modification except modifications or adjustments specifically described
in this Product reference guide, adjustment or repair, or any attempt to do any of the foregoing,
by anyone other than TAGSYS.
ƒ
Any action on Product that prevents TAGSYS from performing an inspection and test of the
Product in case of a warranty claim.
ƒ
Tampering with or abuse of the Product.
ƒ
Any use or incorporation by the Buyer or a third party of TAGSYS' Product into life saving or life
support devices or systems, or any related products, TAGSYS expressly excludes any liability
for such use.
October 2006
Revision 1.1
31/33
Medio S004 EVM
8.2.1 General Provisions
This warranty sets forth the full extent of TAGSYS responsibility regarding the Product.
In any event, TAGSYS warranty is strictly limited to (at TAGSYS’ sole option) the replacement or
refund of the Products purchase price to TAGSYS, of Products considered as defective by
TAGSYS.
The remedy provided above is in lieu and to the exclusion of all other remedies, obligations or
liabilities on the part of TAGSYS for damages, whether in contract, tort or otherwise, and including
but not limited to, damages for any defects in the Products or for any injury, damage, or loss
resulting from such defects or from any work done in connection therewith or for consequential
loss, whether based upon lost goodwill, lost resale profits, impairment of other goods or arising
from claims by third parties or otherwise.
TAGSYS disclaims any explicit warranty not provided herein and any implied warranty, guaranty or
representation as to performance, quality and absence of hidden defects, and any remedy for
breach of contract, which but for this provision, might arise by implication, operation of law, custom
of trade or course of dealing, including implied warranties of merchantability and fitness for a
particular purpose.
8.2.2 How to Return Defective Products
The Buyer shall notify TAGSYS of the defects within 15 working days after the defects are
discovered.
Defective Products must be returned to TAGSYS after assignment by a TAGSYS Quality
Department representative of an RMA (Return Material Authorization) number. No Products shall
be returned without their proof of purchase and without the acceptance number relating to the
return procedure.
All Products shall be returned with a report from the Buyer stating the complete details of the
alleged defect.
Call +33 4 91 27 57 36 for return authorization and shipping address.
If returned Products prove to be non-defective, a charge will be applied to cover TAGSYS’ analysis
cost and shipping costs.
If the warranty does not apply for returned Products (due to age, or application of a warranty
exclusion clause), a quote for replacement will be issued, and no replacement will be granted until
a valid purchase order is received. If no purchase order is received within 30 days after the date of
TAGSYS quote, TAGSYS will return the products and charge the analysis cost and shipping costs.
All replaced Products shall become the property of TAGSYS.
The Product Return Form is included on the following page. This form should accompany any
product you need to return to TAGSYS for analysis in the event of a problem.
32/33
Revision 1.1
October 2006
Medio S004 EVM
Product Return Form
Customer Profile:
Company: ................................................................
Address: ..................................................................
.................................................................................
.................................................................................
City & State:.............................................................
Zip Code: .................................................................
Country: ...................................................................
Contact Name: .......................................................
Contact e-mail: ......................................................
Contact Phone: ......................................................
Contact Fax:...........................................................
Order identification:
Product Name:.........................................................
Order Number (OEF):..............................................
Invoice Number: .....................................................
Return Quantity: ....................................................
Reason for return:
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
To inform TAGSYS of this return, please email it to
RMA@tagsysrfid.com
Address to ship the product with this document attached:
TAGSYS
QUALITY DEPARTMENT
180, chemin de Saint Lambert
13821 La Penne sur Huveaune France
To inform TAGSYS of this return, please also fax it to your Customer Service Representative
+33 491-275-701
Return Procedure:
The product returned will go through stringent quality controls.
A final analysis report will be sent to you as soon as possible.
Please contact your Quality Service representative for further details.
+33 491-275-736
This product bears the selective sorting symbol for waste electrical and electronic
equipment (WEEE)
This means that this product must be handled pursuant to European Directive
2002/96/EC in order to be recycled or dismantled to minimize its impact on the
environment.
October 2006
Revision 1.1
33/33

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 33
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:a9a25656-aa2e-4a5e-9fa6-52fd51ff09d0
Producer                        : Acrobat Distiller 6.0 (Windows)
Company                         : TAGSYS
Date 0020enregistrement         : October 2006
N00 B00020du 0020document       : 12125A1
Source Modified                 : D:20070116111209
Headline                        : User's Guide
Creator Tool                    : Acrobat PDFMaker 6.0 pour Word
Modify Date                     : 2007:01:16 12:18:21+01:00
Create Date                     : 2007:01:16 12:12:55+01:00
Metadata Date                   : 2007:01:16 12:18:21+01:00
Document ID                     : uuid:a4780507-995c-4b86-bb14-68c307511878
Version ID                      : 2
Format                          : application/pdf
Title                           : Medio S004 EVM
Creator                         : Michael Colantoni
Description                     : User's Guide
Subject                         : 1.1
Tagged PDF                      : Yes
Author                          : Michael Colantoni
Keywords                        : 1.1
Date Enregistrement             : October 2006
N Du Document                   : 12125A1
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QHKMEDIOS004EVAL

Navigation menu