Tantalus Systems 532856 TSC Security System User Manual
Tantalus Systems Corp TSC Security System
User Manual
Tantalus Systems Corp. TSC Security System Keypad Quick Access User Manual Quick Access User Manual 1. Introduction Congratulations on purchasing the Tantalus TSC Security System – This system is so simple you shouldn’t need a user manual. 2. Using the Keypad The keys on the user keypad have functionality as described below. 0-9 Used to enter access codes and change Date and Time Panic Sounds an Alert and registers a Panic condition to the Monitoring Station Fire Sounds an Alert and registers a Fire condition to the Monitoring Station Home/Away Selects home or away mode for system srming Arm Quick arm the system . Exit through entrance/exit door when system already armed. Meter Selects meter and displays consumption Yes/No Yes, No selection (sub-keys on 7 and 0 keys) Test Displays menu items on keypad display. 3. Arming The System The system can be armed as described below. Zone(s) Open Zone name Green light is OFF. Check that all the doors and windows are closed and that motion has stopped in areas covered by motion detectors. System Ready Enter Code To Arm Green light is ON . Enter your access code. As each digit of the code is entered, an “X” will appear on the Keypad screen. System Armed Exit Delay On The Red light will flash. The keypad beeper sound for the duration of the exit period. You may leave through the exit door and all sensors will be armed or stay and the system will sound an alarm if a protected door or window is opened. At the end of the exit delay the Red light stays on. 4. Disarming The System The system can be disarmed as described below. When entering through a Entry door, the keypad will beep and the entry delay will begin, reminding you to disarm the system. The keypad will display the following message… System Armed Enter Code Enter your access code. The Red light will go OFF and the keypad will beep. If an error is made entering the code, re-enter your code correctly. System Disarmed No Alarm Memory Green light is On if the system is ready. System Disarmed Alarm in Memory If an alarm occurred while the system was armed, this message will appear and the Red light will flash. After 5 seconds the Keypad will display… “Zone name” View next? The zones that caused the alarm are displayed. Press Yes to view additional zones Clear Alarm Memory? Press Yes to clear 5. Menu/Test Key Press the Menu/Test key for the following: • Zone Bypassing • Setting Time and Date • Door Chime • Changing Access Codes • Replacing System Components • Installation Walk test Zone Bypass Zone Open or System Ready Entrance/exit and fire zones cannot be bypassed. Display shows…. Press Menu/Test Enter any access code Enter Code To Arm Open zones are displayed first Bypass? Press the Yes/No key to bypass the displayed zone. After selection the next zone is displayed. “Zone Name” Bypass? “O” will appear if a zone is open and not bypassed. “Zone Name” O Bypass? “Zone Name” B “B” will appear on the display to show the zone is bypassed. After 5 seconds of inactivity display returns to 5A If system is now ready to arm display shows… System Ready Bypass On Bypass active Press Menu/Test again for additional menu items. The Master code must have been entered. MM/DD/YY HH:MM Enter Date and Time or press Menu for next menu item. Door Chime OFF Turn ON? Yes turns door chime on, No leaves it off Press Menu/Test again Edit Access Codes Select number of access code to edit, “M” represents the master code. 1(M) 2 3 Access Code 2 Enter new code or press Menu to return to ” Edit Access Codes” XXXX Code is XXXX Confirm? Press Yes to confirm Replacing System Components Replace System Press the Yes key to replace system components. Sensors? Contact installer Controller. “Zone Name” The Keypad will display the first component that may be replaced Press the No key to select the next component or press the Yes key to replace this component . Replace? to replace Keypad and Remove Component The keypad will wait two minutes for you to And Press Yes remove component and press the Yes key. The Keypad will beep. Enter New Comp # [XXXXXXXXX] # is [XXXXXXXX] Enter the new component’s Serial Number . If an error is made press No to re-enter. Add Batteries to the new component. Press Yes to confirm the Serial Number or No to return to previous Confirm? Start Walk Test? Press Yes to start walk test. Walk Test Active To Stop Press No The keypad will display this message during the walk test. When a sensor is activated the Keypad will sound a series of beeps. 6. System Messages Another Keypad In Use Only one keypad may be used at a time. Communication The Controller was unable to communicate with the monitoring station. Failure Contact your installer for service and press Bypass to clear message. Low Battery Change the battery on the named device or bypass the “Zone/Device name” zone. Contact installer if device is the controller. Sensor Fault Contact your installer for service. Press Bypass to bypass the sensor “Zone/Device name” or clear the message. Loss of Clock Press Menu to adjust time or Bypass to clear message. “Device Name” AC Make sure the device is plugged in or contact installer.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Create Date : 2000:04:28 22:20:30 Producer : Acrobat Distiller 4.0 for Windows Modify Date : 2000:04:28 22:20:32-04:00 Page Count : 6EXIF Metadata provided by EXIF.tools