Tantalus Systems N900 NC-90 NETWORK CONTROLLER User Manual NC 900 UserManual

Tantalus Systems Corp NC-90 NETWORK CONTROLLER NC 900 UserManual

Users Manual

Download: Tantalus Systems N900 NC-90 NETWORK CONTROLLER User Manual  NC 900  UserManual
Mirror Download [FCC.gov]Tantalus Systems N900 NC-90 NETWORK CONTROLLER User Manual  NC 900  UserManual
Document ID1363312
Application IDef7hR5yHcTSdL7wzCSeviA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize70.16kB (876995 bits)
Date Submitted2010-10-20 00:00:00
Date Available2010-10-20 00:00:00
Creation Date2010-09-13 11:04:58
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2010-09-13 11:04:58
Document TitleMicrosoft Word - _NC-900_ UserManual.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: mark.fairburn

USER GUIDE
September 01, 2010
KT-100036
TUNet NC-900
®
NETWORK COLLECTOR
Tantalus Systems Corp.
301– 3480 Gilmore Way Burnaby BC V5G 4Y1 Canada
p 604.299.0458 | f 604.451.4111
www.tantalus.com
LEGAL NOTICES
This Guide, and any associated software, is being provided to you only as a licensee pursuant to legal agreements with
Tantalus Systems Corp. that govern your rights and all other aspects of the relationship, and prevail over the legal notices
herein to the extent of any inconsistency.
INFORMATION SUBJECT TO CHANGE The products and methods described in this Guide are the subject of continuous
development and so the information contained herein may change without notice.
REGULATORY AND SAFETY The products and methods described in this Guide are to be handled and/or performed
only by properly trained personnel who understand and strictly follow the instructions of this Guide, including all the
regulatory and safety rules. Failure to so follow may void your legal remedies and regulatory authorizations, amongst
other legal effects.
INTELLECTUAL PROPERTY
Copyright Notice © 2010 Tantalus Systems Corp. All rights reserved.
The copyright notice on this Guide does not indicate any actual or intended publication of any confidential information or
trade secrets contained in or embodied by any associated software.
No part of this Guide, or any associated software, may be reproduced, adapted, translated, stored, or transmitted in any
form or by any means except with prior written permission of Tantalus Systems Corp. or as explicitly allowed by copyright
laws applicable to your situation. This Guide contains proprietary information of Tantalus Systems Corp. that may be
disclosed only to your permitted contractors and customers who need to know.
Trademarks Tantalus, TUNet, Tantalus Utility Network, the stylized T logo, and the names of the products and
services offered therewith, are trademarks of Tantalus Systems Corp. All other product and brand names referenced
herein may be trademarks of their respective owners.
Patents The information and technology described in this Guide, and any associated products, methods, or software,
may be the subject of patents and pending applications of Tantalus Systems Corp. and/or its licensees.
WARRANTY
LIMITATION OF LIABILITY. THE INFORMATION IN THIS GUIDE IS PROVIDED "AS IS" WITH NO WARRANTY
WHATSOEVER AND TANTALUS SYSTEMS CORP. SPECIFICALLY DISCLAIMS ANY WARRANTIES, CONDITIONS,
OR REPRESENTATIONS (EXPRESS OR IMPLIED, ORAL OR WRITTEN) WITH RESPECT TO THE GUIDE OR ANY
PART THEREOF, INCLUDING ANY OR ALL WARRANTIES, CONDITIONS OR REPRESENTATIONS OF TITLE,
MERCHANTABILITY, NON-INFRINGEMENT FITNESS FOR A PARTICULAR PURPOSE (WHETHER OR NOT
TANTALUS SYSTEMS CORP. KNOWS, HAS REASON TO KNOW, HAS BEEN ADVISED, OR IS OTHERWISE IN
FACT AWARE OF ANY SUCH PURPOSE), WHETHER ALLEGED TO ARISE BY LAW, EQUITY, STATUTE OR
GOVERNMENTAL POLICY, BY REASON OF CUSTOM OR USAGE IN THE TRADE, OR BY COURSE OF DEALING. IN
NO EVENT WILL TANTALUS SYSTEMS CORP. BE LIABLE FOR ANY DAMAGES OR COSTS WHATSOEVER OR
ANY SPECIAL, INDIRECT, PUNITIVE, INCIDENTAL AND CONSEQUENTIAL DAMAGES, OR ANY LOST PROFITS OR
LOST SAVINGS, EVEN IF IT HAS BEEN ADVISED OF THE POSSIBILITY THEREOF. THE AGGREGATE LIABILITY
OF TANTALUS SYSTEMS CORP. AND ITS REPRESENTATIVES (INCLUDING ITS EMPLOYEES, OFFICERS,
DIRECTORS, AGENTS, LICENSORS, DISTRIBUTORS AND SUPPLIERS) IN CONNECTION WITH THIS GUIDE
(WHETHER IN TORT, CONTRACT OR OTHERWISE) IS LIMITED ACCORDING TO THE GOVERNING LEGAL
AGREEMENTS. THESE LIMITATIONS SHALL APPLY WHETHER OR NOT THERE IS A FUNDAMENTAL BREACH OF
CONTRACT. SOME JURISDICTIONS CURTAIL OR PROHIBIT LIMITATIONS OF LIABILITIES, AND THEREFORE THE
ABOVE LIMITATIONS MAY NOT APPLY TO YOUR SITUATION.
EXPORT CONTROL Export of this Guide and its information may be controlled by the laws of the United States of
America, Canada and the laws that govern you. Export in contravention of such laws is strictly prohibited.
REGULATORY NOTICES
FCC PART 15 NOTICE, USA
The devices described herein comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. The device may not cause harmful interference.
2. The device must accept any interference received, including interference that may cause undesired operation.
The device is specifically designed to be used under Section 15.247 of the FCC Rules and Regulations. Any unauthorized
modification or changes to this device without the express approval of Tantalus Systems Corp. may void the user’s
authority to operate this device.
Furthermore, this device is intended to be used only when installed in accordance with the instructions outlined in the
installation manual. Failure to comply with these instructions may also void the user’s authority to operate this device.
TABLE OF CONTENTS
1 :: Product Description.............................................................................................................................. 1
1.1
Product Specification: NC-900 Network Collector ..................................................................... 1
2 :: Configuring and Installing the NC-900 ................................................................................................ 2
2.1
Programming Instructions for the Meter Shop (NC-900) ........................................................... 3
2.2
Registering the NC-900 on the Network .................................................................................... 4
3 :: DT-400 Programming Software Guide................................................................................................. 5
3.1
Programming Quick Start .......................................................................................................... 6
3.2
TUNet User Account.................................................................................................................. 7
3.2.1 Configuring a Dynamic Network Addressing Scheme................................................... 8
3.2.2 Configuring a Static Network Addressing Scheme...................................................... 10
3.2.3 Configuring Options .................................................................................................... 12
3.2.4 Working with Log Files ................................................................................................ 13
3.3
System Administration Account ............................................................................................... 15
3.3.1 Configuring the DT-400 for TUNet programming ........................................................ 15
3.3.2 Configuring the DT-400 for remote login using DHCP Addressing ............................. 15
3.3.3 Configuring the DT-400 for remote login using Static Addressing............................... 15
3.3.4 Setting the DT-400 Date/Time .................................................................................... 16
3.3.5 Setting the Unit ID....................................................................................................... 16
3.3.6 Shutdown .................................................................................................................... 16
3.4
Reprogramming Devices with Static Addresses ...................................................................... 17
3.5
Programming Error Codes....................................................................................................... 19
4 :: Contact nformation ............................................................................................................................. 20
1 :: Product Description
The TUNet NC-900 Network Controller is as an array of TUNet devices that provides increased
connectivity distances, thus permitting increased network coverage. It is designed for utilities that want
to drive more value from an existing Ethernet system by using Ethernet as the backbone for TUNet data
transport.
The NC-900 Network Controller consists of two components: the internal control unit, and the antenna
mast.. The internal control unit contains the individual radios and all digital components necessary to
gather meter readings, power quality data, and outage reports from multiple endpoints and relays
information to the operations center over an Ethernet data network. The antenna mast has 1 dedicated
receive and transmit antennas connected to it and is intended to be mounted 200ft in the air in the
direction of its intended coverage area. An NC-900 can also send commands to individual or groups of
LAN devices using the standard TUNet procedures.
1.1 Product Specification: NC-900 Network Collector
Switching Capacity
10/100 Ethernet Switch, RJ45
Operating Temperature
-22 to 130°F (-30 to +50°C)
Operating Humidity
5% to 95% non-condensing
Outdoor Rating
Outdoor Antennas - NEMA 3R certified rain-proof
TUNet NC-900 Network Collector Install Guide
Doc No. KT-100036
page 1
2 :: Configuring and Installing the NC-900
Before the NC-900 is ready for installation in the field, it must be
configured to operate on the Utility’s network.
Contact the System Administrator for the correct settings.
Page 2
Tantalus Systems Corp.
Released: 2010/1/31
2.1 Programming Instructions for the Meter Shop (NC-900)
Ensure that you have a DT-400 Programming Station .
1.
Remove the NC-900 from the box. Plug the Ethernet cable into RJ-45 port.
2.
Ensure that the DT-400 Programmer is powered and connected to the NC-900 using a
crimped-style Ethernet cable.
3.
Power up the NC-900.
4.
Start the programming software on the DT-400 and follow the prompts. Refer to
Section 3 :: DT-400 Programming Software Guide on page 5 for more information.
When the process is finished, the DT-400 programmer will provide notification on whether the
programming was successful.
TUNet NC-900 Network Collector Install Guide
Doc No. KT-100036
page 3
2.2 Registering the NC-900 on the Network
Each NC-900 Network Collector must be registered on the Tantalus Network Server as part of the
activation process. This must be done by individually configuring the 4 NC-90 modules situated in
the NC-900 Network Controller.
Each NC-90 module in the NC-900 has a unique identifier called the Network ID located on an
outside label. No two devices produced by Tantalus have the same Network ID.
To successfully activate an NC-900 on a server, you must record or scan the 10-digit TUNet
Network ID located on the label on the back of the NC-900 and enter it into the Network Server.
Refer to Working with WAN Portals in the TUNet User Guide: Network Administrator for details on
where to enter this information.
Page 4
Tantalus Systems Corp.
Released: 2010/1/31
3 :: DT-400 Programming Software Guide
Configuring an NC-900 Network Collector using the programmer is similar to configuring any home
network router. You must choose a dynamic or static network addressing scheme, and then enter the
address of the NS-2000 Network Server.
The DT-400 runs in two modes:
•
The “TUNet User” account which is used to program the NC-90 devices. This account can also
view or download programming log files over USB.
•
The “System Administrator” account which is used to change the network settings of the DT400. This account also is used to set up the date and time zone for the programmer.
An online help file is available on the DT-400 which will provide more detailed explanations. If you do
not know the network address, or if you are unclear about which addressing scheme to choose for the
NC-90, speak to your Network Administrator.
Note: Please contact Tantalus Technical Support for passwords to the two accounts.
TUNet NC-900 Network Collector Install Guide
Doc No. KT-100036
page 5
3.1 Programming Quick Start
Note: Ensure that the date, time, and time zone have been set under the sysadmin account before first
use of the DT-400. Refer to section 3.3.4 for details.
EQUIPMENT REQUIRED
•
DT-400 laptop
•
Ethernet Cable
NETWORK SETTINGS PROVIDED BY SYSTEM ADMINISTRATOR
Dynamic IP Scheme
Time Zone Offset
________________
Static IP Scheme
Time Zone Offset
________________
IPNM Server Address ________________
IPNM Server Address _______________
IPNM Port Number __________________
IPNM Port Number _________________
IP address for Device _______________
Netmask _________________________
Gateway _________________________
DNS ____________________________
*** Note the IPNM (IP Network Manager) server address is typically at the same address as the
Tantalus Network Server.
PROGRAMMING QUICK START PROCEDURE
1.
Start the laptop and log in as “tunet”.
2.
Plug the network cable into NC-90 port and the other end to the laptop.
3.
Apply power to the NC-900 Network Controller.
4.
Wait approximately 90 seconds until the solid orange status light on the NC-90 changes to either
solid red (factory default / never programmed), flashing orange (previously programmed) or flashing
red (previously programmed but no network connection found).
5.
Proceed to configure the TUNet NC-90 as explained in the following sections.
Note: The TUNet NC-90 reboots every 5 minutes if it is not communicating with a Tantalus Network
Server. This is indicated by the status light changing to flashing red 6 minutes after initial power up. This
may result in an unsuccessful programming attempt. It is recommended to remove power for 20
seconds and reapply. The device will then go through the normal startup cycle.
Page 6
Tantalus Systems Corp.
Released: 2010/1/31
3.2 TUNet User Account
Before you can use the DT-400 programmer to program the NC-90, you must choose between a
dynamic or static network addressing scheme. Tantalus recommends dynamic addressing in all cases,
unless there is a specific technical reason that static addressing must be used instead.
If you are unclear about which addressing scheme to choose, speak to your Network Administrator.
LAUNCHING DEVICE CONFIGURATION
1.
Log in to the DT-400 laptop. The DT-400 Device Configuration Tool will start automatically and
you will see a menu of the available options.
2.
Select one of the available options:
Tantalus DT-400 Device Configuration Tool (version 200.0004).
Select one of the following options
1) Configure for Static Network Address
2) Configure for DHCP
3) Options (DeviceIP=24.25.26.28)
4) Copy log file to USB memory stick
5) View log file
6) Help
7) Quit
[2]>_
TUNet NC-900 Network Collector Install Guide
Doc No. KT-100036
page 7
3.2.1
Configuring a Dynamic Network Addressing Scheme
Dynamic network addressing is the simplest network addressing scheme to setup and to maintain.
TO CONFIGURE A DYNAMIC NETWORK ADDRESSING SCHEME
Note: Make sure that the cable from the DT-400 is plugged into the NC-90 and is powered up. The
NC-90 is ready for configuration when the status light on the NC-90 is either solid red, flashing
orange, or flashing red.
1.
To configure for DHCP, choose 2.
2.
At each prompt, enter the network settings provided by your Network Administrator or press
 to accept the last entered values shown in brackets (green).
Tantalus DT-400 Device Configuration Tool (version 200.0004).
Select one of the following options
1) Configure for Static Network Address
2) Configure for DHCP
3) Options (DeviceIP=24.25.26.28)
4) Copy log file to USB memory stick
5) View log file
6) Help
7) Quit
[2]>2
TZ offset(5)>
IPNM Address (10.1.1.75)>
IPNM Port(12345)> _
TZ Offset: Timezone offset is the number of hours to be added to the local STANDARD time
to obtain Universal Time (UTC).
Time Zone
Page 8
Hours to Input
Pacific (PST)
Mountain (MST)
Central (CST)
Eastern (EST)
Atlantic (AST)
Tantalus Systems Corp.
Released: 2010/1/31
IPNM Address: This is the IP address of the Tantalus IPNM Server (usually the same as the
Tantalus Network Server).
Example: 66.119.167.133
IPMN Port: This is the port number of the Tantalus IPNM Server that the NC-90 uses for
communication.
At the last prompt, you will see a list of the configuration information that is about to be sent to
the NC-90. Some values are supplied by the program.
3.
Press  to send the configuration to the NC-90.
OR, type “n” to cancel.
[2]>2
TZ offset(5)>
IPNM Address (10.1.1.75)>
IPNM Port(12345)>
The configuration file you are about to send:
TZvar = TUN+5
IPNMAddr = 10.1.1.75
IPNMPort = 12345
Interface = eth0
InterfaceType = inet
NetworkAddressing = dhcp
Configure device? ( [ y ] n ):_
TUNet NC-900 Network Collector Install Guide
Doc No. KT-100036
page 9
3.2.2
Configuring a Static Network Addressing Scheme
Static configuration requires additional variables and is much more difficult to change. In addition, an
error in setting up a static addressing scheme may cause serious technical complications within your
network.
Warning
Warning
An incorrect net mask setting may render the NC-90 unable to communicate
with the Network Server or the DT-400.
Each NC-90 must have a unique network address. If multiple NC-90’s have
the same network address, this will cause communications problems on the
NS-2000 Network Server.
TO CONFIGURE A STATIC NETWORK ADDRESSING SCHEME
Note: Make sure that the cable from the DT-400 is plugged into the NC-90 and is powered up.
The NC-90 is ready for configuration when the status light on the NC-90 is either solid red,
flashing orange, or flashing red.
1.
To configure for a static network address, choose 1.
2.
At each prompt, enter the network settings provided by your Network Administrator or press
 to accept the last entered values shown in brackets (green).
[2]>1
TZ offset(5)>
IPNM Address >10.1.1.75
IPNM Port>12345
Device IP Address >10.1.50.32
Net Mask >255.255.0.0
Gateway >10.1.1.20
DNS 1 >10.1.1.25
DNS 2 >
The configuration file you are about to send:
TZvar = TUN+5
IPNMAddr = 10.1.1.75
IPNMPort = 12345
Interface = eth0
InterfaceType = inet
NetworkAddressing = static
IpcIP = 10.1.50.32
IpcMask = 255.255.0.0
IpcNetwork = 10.1.0.0
IpcGateway = 10.1.1.20
IpcDNS1 = 10.1.1.25
Configure device? ( [ y ] n ):_
Page 10
Tantalus Systems Corp.
Released: 2010/1/31
TZ Offset: Timezone offset is the number of hours to be added to the local STANDARD time
to obtain Universal Time (UTC).
Time Zone
Hours to Input
Pacific (PST)
Mountain (MST)
Central (CST)
Eastern (EST)
Atlantic (AST)
IPNM Address: This is the IP address of the Tantalus IPNM Server (usually the same as the
Tantalus Network Server).
Example: 66.119.167.133
IPMN Port: This is the port number of the Tantalus IPNM Server that the NC-90 uses for
communication.
IP: This is the unique IP address to be assigned to the NC-90 to be programmed.
Net Mask: This is the network mask on the network where the NC-90 is to be installed.
Gateway: This is the gateway IP address on the network.
DNS 1: This is the 1st DNS IP address. At least one DNS address must specified.
DNS 2: This is the 2nd DNS IP address (optional).
DNS 3: This is the 3rd DNS IP address (optional).
At the last prompt, you will see a list of the configuration information that is about to be sent to
the NC-90. Some values are supplied by the program.
3.
Press  to send the configuration to the NC-90.
OR, type “n” to cancel.
TUNet NC-900 Network Collector Install Guide
Doc No. KT-100036
page 11
3.2.3
Configuring Options
The DT-400 Programmer laptop is designed to be directly connected to the NC-90 without requiring a
switch or router. The laptop has a DHCP server that distributes a specific IP address to any NC-90 that
requests one.
You can use the Device IP option to control which IP address the laptop assigns to the NC-90 for
purposes of programming. Most of the time you will just use the default address. But under certain
circumstances, you may want to update the IP address from the default setting. For example, you might
do this if a statically addressed NC-90 requires reprogramming.
CONFIGURING A SPECIFIC IP ADDRESS
1.
To configure a specific IP address, choose 3.
2.
Enter the IP address that the program will attempt to communicate to or press enter to accept
the default in brackets.
3.
Press  to save the settings to the programmer.
Tantalus DT-400 Device Configuration Tool (version 200.0004).
Select one of the following options
1) Configure for Static Network Address
2) Configure for DHCP
3) Options (DeviceIP=24.25.26.28)
4) Copy log file to USB memory stick
5) View log file
6) Help
7) Quit
[2]>3
Device IP Address (24.25.26.28)>_
Page 12
Tantalus Systems Corp.
Released: 2010/1/31
3.2.4
Working with Log Files
The DT-400 stores a history of all successful programming sessions. This file is store in .cvs format for
easy importation into third party spreadsheet programs. The file can be viewed on the DT-400 or may
be copied to a USB storage device. The name of the DT-400 (see 3.3.5 Setting the Unit ID) is
appended to the beginning of the export file in the following format“_client.csv”.
The figure below shows a typical output of the log file. The first line in the log file contains the field
names.
timestamp,device-network-id,device-mac-addr,hw-release,fw-release,productid,timezone-offset,ns-ip,ns-port,interface,inet,addressing-type,device-ip,networkmask,network, gateway,dns1,dns2,dns1
2010-01-20 10:35:19,000648D22F,00:25:5A:06:48:D2,307,300,32,TUN+5,10.1.1.105,
12345,eth0,inet,dhcp,,,,,,,
2010-01-20 10:35:24,000648D22F,00:25:5A:06:48:D2,307,300,32,TUN+5,10.1.1.105,
12345,eth0,inet,dhcp,,,,,,,
2010-01-20 10:35:29,000648D22F,00:25:5A:06:48:D2,307,300,32,TUN+5,10.1.1.105,
12345,eth0,inet,dhcp,,,,,,,
2010-01-20 10:36:11,000648D22F,00:25:5A:06:48:D2,307,300,32,TUN+5,10.1.1.105,
12345,eth0,inet,static,10.1.3.250,255.255.252.0,10.1.0.0,10.1.1.1,10.1.1.1,10.1.1.
2,10.1.1.3
2010-01-20 10:36:18,000648D22F,00:25:5A:06:48:D2,307,300,32,TUN+5,10.1.1.105,
12345,eth0,inet,dhcp,,,,,,,
The information is stored in the following format:
Example
Field Name
Description
2010-01-20 10:36:11
timestamp
time stamp when device was programmed
000648D22F
device-network-id
network id for the device
00:25:5A:06:48:D2
device-mac-addr
Mac address
307
hw-release
Hardware revision number
300
fw-release
Overall firmware revision number
32
product-id
Type of tunet device
TUN+5
timezone-offset
timezone offset
10.1.1.105
ns-ip
IP address of the NS server
12345
ns-port
port number of the NS server
eth0
interface
always eth0 for NC-90 (ignore)
inet
inet
always inet (ignore)
static
addressing-type
static or dhcp
10.1.3.250
device-ip
for static device IP address
255.255.252.0
network-mask
for static device network mask
10.1.0.0
network,
for static network portion of IP address
10.1.1.1
gateway,
for static network gateway IP
TUNet NC-900 Network Collector Install Guide
Doc No. KT-100036
page 13
10.1.1.1
dns1,
for network DNS server 1
10.1.1.2
dns2,
for network DNS server 2 (Optional)
10.1.1.3
dns3
for network DNS server 3 (Optional)
When viewing log files on the DT-400, the following commands are available:
Key
Arrow
keys
Function
Scroll up / down 1 line
Scroll left / right
Scroll forward one screen
Scross backward one screen
/pattern
Searches the log file for the pattern you are looking for (case sensitive). The
curser will immediately go to the first instance and highlight any additional
matches.
Example: /2010-01-20
or
/000648D22F
Pressing ‘n’ will go to the next instance. Pressing ‘N’ will go to the previous
instance.
Page 14
Additional Commands
Exits the viewer
Tantalus Systems Corp.
Released: 2010/1/31
3.3 System Administration Account
The System Administration account allows initial configuration of the DT-400 and provides pre-set
network configurations that allow Tantalus Technical Support to provide remote servicing.
Tantalus DT-400 System Administration (version 200.0004).
Select one of the following options:
1) Configure DT-400 for TUNet programming
2) Configure for remote login using DHCP Addressing
3) Configure for remote login using Static Addressing
4) Set DT-400 date/time
5) Unit ID
6) Help
7) Shutdown
8) Quit
[1]>_
3.3.1
Configuring the DT-400 for TUNet programming
This is the default state of the DT-400 when first powered up. In this configuration, the DT-400 runs an
internal DHCP server to enable direct communications with a NC-90. Note: the DT-400 will not be able
to communicate to an NC-90 that has a static address assigned to it. Refer to section 3.4 on how to
configure the DT-400 for this scenario.
Once you have configured this setting, the settings will be automatically saved and you will be logged
out of the account. You must log in again to the System Admin account if you want to make further
changes.
3.3.2
Configuring the DT-400 for remote login using DHCP Addressing
Select this option if Tantalus personnel must remotely access the DT-400 when computers on your
network are required to use DHCP. Make sure the DT-400 is connected to your corporate network so
that it can get an IP address. After a successful IP lease is obtained, the program will display the
assigned IP address. Please report this address to Tantalus.
Once you have configured this setting, the settings will be automatically saved and you will be logged
out of the account. You must log in again to the System Admin account if you want to make further
changes.
3.3.3
Configuring the DT-400 for remote login using Static Addressing
Select this option if Tantalus personnel must remotely access the DT-400 when computers on your
network are required to use static IP assignment. You will be asked a series of questions (sample
answer shown after '>' character):
a) IP address for this unit: >10.1.3.80
b) Net Mask: >255.255.252.0
c) Gateway: >10.1.1.1
d) DNS: > 10.1.1.1
TUNet NC-900 Network Collector Install Guide
Doc No. KT-100036
page 15
After a short delay, the program will echo the assigned IP address to the operator. In special
circumstances, this option may also be used to change the network setting of the NC-90 if it was
mistakenly configured for a Static Network Address and the wrong IP was programmed, or if you must
configure it back for DHCP Addressing.
Once you have configured this setting, the settings will be automatically saved and you will be logged
out of the account. You must log in again to the System Admin account if you want to make further
changes.
3.3.4
Setting the DT-400 Date/Time
A new DT-400 programmer will require the date, time and time zone changed. This will ensure that the
programming logs record the correct time. Follow the prompts on the DT-400 screen to update.
3.3.5
Setting the Unit ID
If there is more than one programmer available, it may be beneficial to change the ID of the device. This
can be helpful when reconciling the log files.
The default unit ID is set to tunet02. The DT-400 will add this tag to any log files exported to the usb
stick.
3.3.6
Shutdown
Select this option to shutdown the programmer. This is the same as pressing the power button. It is not
recommended to remove the battery while the programmer is operating.
Page 16
Tantalus Systems Corp.
Released: 2010/1/31
3.4 Reprogramming Devices with Static Addresses
In the event that a statically assigned TUNet device requires reconfiguration of its network parameters,
the DT-400 must be reconfigured to match the same network parameters that were originally assigned
to the device. The DT-400 must then be configured in the options to point to the IP address of the
device that requires reprogramming.
1.
Note the Network ID printed on the NC-90. Use this number to look up the network parameters
previously assigned to the device in the DT-400 programming logs (refer to section 3.2.4 on
working with log files).
Example log file:
Network ID
2009-05-06 16:23:30, 1234567890, 00:25:5A:34:56:87,307,300,32,TUN+5,10.0.0.99,
12345,eth0,inet,static,10.0.0.10, 255,255,255,0,10.0.0.0,10.0.0.1, 10.0.0.1,,
Device IP
Address
Net
Mask
Write down the following: IP ADDRESS (device-IP), NETMASK (network-mask)
IP Address: 10.0.0.10
Netmask: 255.255.255.0
2.
Log out then log back in as “sysadmin”.
3.
Select option 3: “Configure for remote login using Static Addressing”.
The DT-400 now requires an IP address in the same subnet as the NC-90. Take the current IP
Address of the NC-90 and replace the last number with 254. If the last number is already 254
then use 253.
The IP address to be assigned to the DT-400 in this example is 10.0.0.254.
4.
The DT-400 now requires to be assigned the same Net Mask as was assigned to the NC-90.
Enter this in now.
Netmask: 255.255.255.0
5.
Use the following values for the Gateway and DNS:
Gateway: 1.1.1.1
DNS: 1.1.1.1
6.
Logout and log back in as “tunet”.
TUNet NC-900 Network Collector Install Guide
Doc No. KT-100036
page 17
7.
Select Options and select Configure DeviceIP. Set this to the IP ADDRESS of the NC-90 to be
reprogrammed (In this case it is 10.0.0.10).
8.
Connect a network cable from the NC-90 to the DT-400 and insert it into a meter collar.
9.
Apply power to the NC-90. Wait for the lights to change to flashing orange or flashing red
indicating that it is ready to be reprogrammed. The device is now ready to communicate with
the DT-400.
10. Follow the standard programming instructions as described in Section 3.1.
Note: After a statically configured device has been reprogrammed to use dynamic addressing,
the DT-400 must be changed back to Option 1 under the “sysadmin” account to resume
reprogramming of new NC-90’s. Alternatively, the DT-400 may be turned off then restarted to
get back into the default dynamic programming mode.
Page 18
Tantalus Systems Corp.
Released: 2010/1/31
3.5 Programming Error Codes
When attempting to send the configuration to the NC-90, error codes may appear under certain
conditions.
110 – No communication with the TUNet device.
Check the following:
1.
Check correct device IP. The default is 24.25.26.28 for dynamic address programming.
2.
Check network cable connections between the DT-400 and the TUNet device.
3.
Check DT-400 is in the correct network configuration. For dynamic address configuration, choose
option 1 in the sysadmin account. For reprogramming a device that has already been preconfigured with a static address, the DT-400 will have to be configured to match the network setting
of the device. See section Reprogramming Devices with Static Addresses.
4.
Check that the TUNet device is powered by seeing if the status LED is on.
5.
The NC-90 device may have timed out and is restarting. This will occur 6 minutes after power is
first applied. It is recommended to disconnect power to the stick for 20 seconds and reapply.
255 – TUNet Device has started but is not ready.
The NC-90 has not completed its boot up cycle. Try again in 10 seconds.
TUNet NC-900 Network Collector Install Guide
Doc No. KT-100036
page 19
4 :: Contact nformation
TANTALUS SYSTEMS CORP.
Tantalus Systems Corp.
301 – 3480 Gilmore Way
Burnaby, BC Canada V5G 4Y1
T/ 604.299.0458
F/ 604.451.4111
TECHNICAL SUPPORT
TantalusTechsupport@tantalus.com
GENERAL ENQUIRIES
Info@tantalus.com
Page 20
Tantalus Systems Corp.
Released: 2010/1/31

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2010:09:13 11:04:58-07:00
Modify Date                     : 2010:09:13 11:04:58-07:00
Page Count                      : 24
Creation Date                   : 2010:09:13 18:04:58Z
Mod Date                        : 2010:09:13 18:04:58Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : mark.fairburn
Metadata Date                   : 2010:09:13 18:04:58Z
Creator                         : mark.fairburn
Title                           : Microsoft Word - _NC-900_ UserManual.doc
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OZFN900

Navigation menu